A Radiation Oncologist's Journey Through Technological Advancements in Oncology: Reflections on the Proton Therapy Winterschool at Paul Scherrer Institute, Switzerland. Cureus 2023; 15:e39551. [PMID: 37250609 PMCID: PMC10220324 DOI: 10.7759/cureus.39551] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 05/26/2023] [Indexed: 05/31/2023] Open
Abstract
The proton therapy course at the Paul Scherrer Institute (PSI) in Switzerland provided a comprehensive insight into the clinical, physics, and technological aspects of proton therapy, with a particular focus on pencil beam scanning techniques. The program consisted of engaging lectures, hands-on workshops, and facility tours, which covered topics such as the history of proton therapy, treatment planning systems, clinical applications, and future developments. Participants gained practical experience with treatment planning and simulation, while also exploring the challenges associated with various tumor types and motion management. The collaborative and supportive learning environment fostered by the faculty and staff at PSI enriched the educational experience, empowering participants to better serve their patients in the field of radiation oncology.
Collapse
|
2
|
GPU accelerated Monte Carlo scoring of positron emitting isotopes produced during proton therapy for PET verification. Phys Med Biol 2022; 67. [PMID: 36541512 DOI: 10.1088/1361-6560/aca515] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 11/22/2022] [Indexed: 11/23/2022]
Abstract
Objective.Verification of delivered proton therapy treatments is essential for reaping the many benefits of the modality, with the most widely proposedin vivoverification technique being the imaging of positron emitting isotopes generated in the patient during treatment using positron emission tomography (PET). The purpose of this work is to reduce the computational resources and time required for simulation of patient activation during proton therapy using the GPU accelerated Monte Carlo code FRED, and to validate the predicted activity against the widely used Monte Carlo code GATE.Approach.We implement a continuous scoring approach for the production of positron emitting isotopes within FRED version 5.59.9. We simulate treatment plans delivered to 95 head and neck patients at Centrum Cyklotronowe Bronowice using this GPU implementation, and verify the accuracy using the Monte Carlo toolkit GATE version 9.0.Main results.We report an average reduction in computational time by a factor of 50 when using a local system with 2 GPUs as opposed to a large compute cluster utilising between 200 to 700 CPU threads, enabling simulation of patient activity within an average of 2.9 min as opposed to 146 min. All simulated plans are in good agreement across the two Monte Carlo codes. The two codes agree within a maximum of 0.95σon a voxel-by-voxel basis for the prediction of 7 different isotopes across 472 simulated fields delivered to 95 patients, with the average deviation over all fields being 6.4 × 10-3σ.Significance.The implementation of activation calculations in the GPU accelerated Monte Carlo code FRED provides fast and reliable simulation of patient activation following proton therapy, allowing for research and development of clinical applications of range verification for this treatment modality using PET to proceed at a rapid pace.
Collapse
|
3
|
Experimental validation of daily adaptive proton therapy. Phys Med Biol 2021; 66. [PMID: 34587589 DOI: 10.1088/1361-6560/ac2b84] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2021] [Accepted: 09/29/2021] [Indexed: 11/12/2022]
Abstract
Anatomical changes during proton therapy require rapid treatment plan adaption to mitigate the associated dosimetric impact. This in turn requires a highly efficient workflow that minimizes the time between imaging and delivery. At the Paul Scherrer Institute, we have developed an online adaptive workflow, which is specifically designed for treatments in the skull-base/cranium, with the focus set on simplicity and minimizing changes to the conventional workflow. The dosimetric and timing performance of this daily adaptive proton therapy (DAPT) workflow has been experimentally investigated using an in-house developed DAPT software and specifically developed anthropomorphic phantom. After a standard treatment preparation, which includes the generation of a template plan, the treatment can then be adapted each day, based on daily imaging acquired on an in-room CT. The template structures are then rigidly propagated to this CT and the daily plan is fully re-optimized using the same field arrangement, DVH constraints and optimization settings of the template plan. After a dedicated plan QA, the daily plan is delivered. To minimize the time between imaging and delivery, clinically integrated software for efficient execution of all online adaption steps, as well as tools for comprehensive and automated QA checks, have been developed. Film measurements of an end-to-end validation of a multi-fraction DAPT treatment showed high agreement to the calculated doses. Gamma pass rates with a 3%/3 mm criteria were >92% when comparing the measured dose to the template plan. Additionally, a gamma pass rate >99% was found comparing measurements to the Monte Carlo dose of the daily plans reconstructed from the logfile, accumulated over the delivered fractions. With this, we experimentally demonstrate that the described adaptive workflow can be delivered accurately in a timescale similar to a standard delivery.
Collapse
|
4
|
A novel hybrid 3D dose reconstruction approach for pre-treatment verification of intensity modulated proton therapy plans. Phys Med Biol 2021; 66:055015. [PMID: 33470967 DOI: 10.1088/1361-6560/abdd8b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
AIM A novel hybrid three-dimensional (3D) dose reconstruction method, based on planar dose measured at a single shallower depth, was developed for use as patient-specific quality assurance (PSQA) of intensity modulated proton therapy (IMPT) plans. The accuracy, robustness and sensitivity of the presented method were validated for multiple IMPT plans of varying complexities. METHODS AND MATERIALS An in-house MATLAB program was developed to reconstruct 3D dose distribution from the planar dose (GyRBE) measured at 3 g cm-2 depth in water or solid phantom using a MatriXX PT ion chamber array. The presented method was validated extensively for 11 single-field optimization (SFO) and multi-field optimization (MFO) plans on Proteus Plus. A total of 47 reconstructed planar doses at different depths were compared against the corresponding RayStation treatment planning system (TPS) and MatriXX PT measurement using a gamma passing rate (γ%) evaluated for 3%/3 mm. The robustness of the reconstruction method with respect to depth, energy layers, field dimensions and complexities in the spot intensity map (SIM) were analysed and compared against the standard PSQA. The sensitivity of the reconstruction method was tested for plans with intentional errors. RESULTS The presented reconstruction method showed excellent agreement (mean γ% > 98%) and robustness with both TPS-calculated and measured dose planes at all depths (2.97-30 g cm-2), energy layers (82.1-225.5 MeV), field dimensions, target volume (17.7-1000 cm3) and SIMs from both SFO and MFO plans. In comparison to the overall mean ± SD γ% from standard PSQA, the reconstruction method showed reductions in mean γ% within 1% for both standard cubes and clinical plans. The reconstruction method was sensitive enough to detect intentional spot positional errors in a selected energy layer of a plan. CONCLUSION The presented hybrid reconstruction method is sufficiently accurate, robust and sensitive to estimate planar dose at any user-defined depth. It simplifies the measurement setup and eliminates multiple depth measurements.
Collapse
|
5
|
Assessing the advantages of CFR-PEEK over titanium spinal stabilization implants in proton therapy—a phantom study. ACTA ACUST UNITED AC 2020; 65:245031. [DOI: 10.1088/1361-6560/ab8ba0] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
6
|
Clinical commissioning of intensity-modulated proton therapy systems: Report of AAPM Task Group 185. Med Phys 2020; 48:e1-e30. [PMID: 33078858 DOI: 10.1002/mp.14546] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Revised: 08/17/2020] [Accepted: 08/18/2020] [Indexed: 02/06/2023] Open
Abstract
Proton therapy is an expanding radiotherapy modality in the United States and worldwide. With the number of proton therapy centers treating patients increasing, so does the need for consistent, high-quality clinical commissioning practices. Clinical commissioning encompasses the entire proton therapy system's multiple components, including the treatment delivery system, the patient positioning system, and the image-guided radiotherapy components. Also included in the commissioning process are the x-ray computed tomography scanner calibration for proton stopping power, the radiotherapy treatment planning system, and corresponding portions of the treatment management system. This commissioning report focuses exclusively on intensity-modulated scanning systems, presenting details of how to perform the commissioning of the proton therapy and ancillary systems, including the required proton beam measurements, treatment planning system dose modeling, and the equipment needed.
Collapse
|
7
|
Beam commissioning of the first compact proton therapy system with spot scanning and dynamic field collimation. Br J Radiol 2019; 93:20190598. [PMID: 31782941 DOI: 10.1259/bjr.20190598] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES To describe the measurements and to present the results of the beam commissioning and the beam model validation of a compact, gantry-mounted, spot scanning proton accelerator system with dynamic layer-by-layer field collimation. METHODS We performed measurements of depth dose distributions in water, spot and scanned field size in air at different positions from the isocenter plane, spot position over the 20 × 20 cm2 scanned area, beam monitor calibration in terms of absorbed dose to water and specific field collimation measurements at different gantry angles to commission the system. To validate the beam model in the treatment planning system (TPS), we measured spot profiles in water at different depths, absolute dose in water of single energy layers of different field sizes and inversely optimised spread-out Bragg peaks (SOBP) under normal and oblique beam incidence, field size and penumbra in water of SOBPs, and patient treatment specific quality assurance in homogeneous and heterogeneous phantoms. RESULTS Energy range, spot size, spot position and dose output were consistent at all gantry angles with 0.3 mm, 0.4 mm, 0.6 mm and 0.5% maximum deviations, respectively. Uncollimated spot size (one sigma) in air with an air-gap of 10 cm ranged from 4.1 to 16.4 mm covering a range from 32.2 to 1.9 cm in water, respectively. Absolute dose measurements were within 3% when comparing TPS and experimental data. Gamma pass rates >98% and >96% at 3%/3 mm were obtained when performing 2D dose measurements in homogeneous and in heterogeneous media, respectively. Leaf position was within ±1 mm at all gantry angles and nozzle positions. CONCLUSIONS Beam characterisation and machine commissioning results, and the exhaustive end-to-end tests performed to assess the proper functionality of the system, confirm that it is safe and accurate to treat patients. ADVANCES IN KNOWLEDGE This is the first paper addressing the beam commissioning and the beam validation of a compact, gantry-mounted, pencil beam scanning proton accelerator system with dynamic layer-by-layer multileaf collimation.
Collapse
|
8
|
Daily adaptive proton therapy - the key to innovative planning approaches for paranasal cancer treatments. Acta Oncol 2019; 58:1423-1428. [PMID: 31364904 DOI: 10.1080/0284186x.2019.1641217] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Background: For proton therapy of paranasal tumors, field directions avoiding volumes that might change during therapy are typically used. If the plan is optimized on the daily anatomy using daily adapted proton therapy (DAPT) however, field directions crossing the nasal cavities might be feasible. In this study, we investigated the effectiveness of DAPT for enabling narrow-field treatment approaches. Material and methods: For five paranasal tumor patients, representing a wide patient spectrum, anatomically robust 4-field-star and narrow-field plans were calculated and their robustness to anatomical and setup uncertainties was compared with and without DAPT. Based on the nominal planning CTs, per patient up to 125 simulated CTs (simCTs) with different nasal cavity fillings were created and random translations and rotations due to patient setup uncertainties were further simulated. Plans were recalculated or re-optimized on all error scenarios, representing non-adapted and DAPT fractions, respectively. From these, 100 possible treatments (60 GyRBE, 30 fx) were simulated and changes in integral dose, target and organs at risk (OARs) doses evaluated. Results: In comparison to the 4-field-star approach, the use of narrow-fields reduced integral dose between 29% and 56%. If OARs did not overlap with the target, OAR doses were also reduced. Finally, the significantly reduced target coverage in non-adapted treatments (mean V95 reductions of up to 34%) could be almost fully restored with DAPT in all cases (differences <1%). Conclusions: DAPT was found to be not only an effective way to increase plan robustness to anatomical and positional uncertainties, but also opened the possibility to use improved and more conformal field arrangements.
Collapse
|
9
|
Dosimetric validation of Monte Carlo and analytical dose engines with raster-scanning 1H, 4He, 12C, and 16O ion-beams using an anthropomorphic phantom. Phys Med 2019; 64:123-131. [DOI: 10.1016/j.ejmp.2019.07.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/12/2019] [Revised: 06/30/2019] [Accepted: 07/01/2019] [Indexed: 12/15/2022] Open
|
10
|
Abstract
In advanced ion therapy, the visualization of the range of incident ions in a patient's body is important for exploiting the advantages of this type of therapy. It is ideal to use radioactive ion beams for in-beam positron emission tomography (PET) imaging in particle therapy due to the high quality of PET images caused by the high signal-to-noise ratio. We have shown the feasibility of this idea through an in-beam PET study for 11C and 15O ion beams using the dedicated OpenPET system. In this work, we investigate the potential difference between the Bragg peak position and the position of the maximum detected positron-emitting fragments by a PET system for the radioactive beams of 11C and 15O. For this purpose, we measured the depth dose in a water phantom and performed PET scans of an irradiated PMMA phantom for the available beams of 11C and 15O at the Heavy Ion Medical Accelerator in Chiba (HIMAC). Then, we simulated the depth dose profiles in the water phantom and the yield of the positron-emitting fragments in a PMMA phantom for both available beams using the Monte Carlo code PHITS. The positions of the Bragg peak and maximum positron-emitting fragments from the measurements were well reproduced by simulation. The effect of beam energy broadening on the positional differences between two peaks was studied by simulating an irradiated PMMA phantom. The differences in position between the Bragg peak and the maximum positron-emitting fragments increased when the beam energy spread was broadened, although the differences were zero for the ideal mono-energetic beams. Greater differences were observed for 11C ion beams compared to 15O ion beams, although both beams had the same range in water, and the higher energy corresponded to a larger difference. For the known energy spread of the beams, the predicted differences between two peaks from the simulation were consistent with the measured data within submillimetre agreement.
Collapse
|
11
|
Methodology paper: a novel phantom setup for commissioning of scanned ion beam delivery and TPS. Radiat Oncol 2019; 14:77. [PMID: 31072382 PMCID: PMC6509855 DOI: 10.1186/s13014-019-1281-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 04/25/2019] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Commissioning of treatment planning systems (TPS) and beam delivery for scanned light ion beams is an important quality assurance task. This requires measurement of large sets of high quality dosimetric data in anthropomorphic phantoms to benchmark the TPS and dose delivery under realistic conditions. METHOD A novel measurement setup is described, which allows for an efficient collection of a large set of accurate dose data in complex phantom geometries. This setup allows dose measurements based on a set of 24 small volume ionization chambers calibrated in dose to water and mounted in a holder, which can be freely positioned in a water phantom with various phantoms mounted in front of the water tank. The phantoms can be scanned in a CT and a CT-based treatment planning can be performed for a direct benchmark of the dose calculation algorithm in various situations. RESULTS The system has been used for acceptance testing in scanned light ion beam therapy at Heidelberg Ion Beam Therapy Center for scanned proton and carbon ion beams. It demonstrated to be useful to collect large amounts of high quality data for comparison with the TPS calculation using various phantom geometries. CONCLUSION The setup is an efficient tool for commissioning and verification of treatment planning systems. It is especially suited for dynamic beam delivery, as many data points can be obtained during a single plan delivery, but can be adapted also for other dynamic therapies, like rotational IMRT.
Collapse
|
12
|
Evaluation of the ray-casting analytical algorithm for pencil beam scanning proton therapy. Phys Med Biol 2019; 64:065021. [PMID: 30641496 DOI: 10.1088/1361-6560/aafe58] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
For pencil beam scanned (PBS) proton therapy, analytical dose calculation engines are still typically used for the optimisation process, and often for the final evaluation of the plan. Recently however, the suitability of analytical calculations for planning PBS treatments has been questioned. Conceptually, the two main approaches for these analytical dose calculations are the ray-casting (RC) and the pencil-beam (PB) method. In this study, we compare dose distributions and dosimetric indices, calculated on both the clinical dose calculation grid and as a function of dose grid resolution, to Monte Carlo (MC) calculations. The analysis is done using a comprehensive set of clinical plans which represent a wide choice of treatment sites. When analysing dose difference histograms for relative treatment plans, pencil beam calculations with double grid resolution perform best, with on average 97.7%/91.9% (RC), 97.9%/92.7% (RC, double grid resolution), 97.6%/91.0% (PB) and 98.6%/94.0% (PB, double grid resolution) of voxels agreeing within ±5%/± 3% between the analytical and the MC calculations. Even though these point-to-point dose comparison shows differences between analytical and MC calculations, for all algorithms, clinically relevant dosimetric indices agree within ±4% for the PTV and within ±5% for critical organs. While the clinical agreement depends on the treatment site, there is no substantial difference of indices between the different algorithms. The pencil-beam approach however comes at a higher computational cost than the ray-casting calculation. In conclusion, we would recommend using the ray-casting algorithm for fast dose optimization and subsequently combine it with one MC calculation to scale the absolute dose and assure the quality of the treatment plan.
Collapse
|
13
|
A linear relationship for the LET-dependence of Gafchromic EBT3 film in spot-scanning proton therapy. ACTA ACUST UNITED AC 2019; 64:055015. [DOI: 10.1088/1361-6560/ab0114] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
14
|
Dosimetric verification of IMPT using a commercial heterogeneous phantom. J Appl Clin Med Phys 2019; 20:114-120. [PMID: 30673145 PMCID: PMC6371016 DOI: 10.1002/acm2.12535] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2018] [Revised: 11/19/2018] [Accepted: 12/30/2018] [Indexed: 11/13/2022] Open
Abstract
The purpose of this study was to propose a verification method and results of intensity‐modulated proton therapy (IMPT), using a commercially available heterogeneous phantom. We used a simple simulated head and neck and prostate phantom. An ionization chamber and radiochromic film were used for measurements of absolute dose and relative dose distribution. The measured doses were compared with calculated doses using a treatment planning system. We defined the uncertainty of the measurement point of the ionization chamber due to the effective point of the chamber and mechanical setup error as 2 mm and estimated the dose variation base on a 2 mm error. We prepared a HU‐relative stopping power conversion table and fluence correction factor that were specific to the heterogeneous phantom. The fluence correction factor was determined as a function of depth and was obtained from the ratio of the doses in water and in the phantom at the same effective depths. In the simulated prostate plan, composite doses of measurements and calculations agreed within ±1.3% and the maximum local dose differences of each field were 10.0%. Composite doses in the simulated head and neck plan agreed within 4.0% and the maximum local dose difference for each field was 12.0%. The dose difference for each field came within 2% when taking the measurement uncertainty into consideration. In the composite plan, the maximum dose uncertainty was estimated as 4.0% in the simulated prostate plan and 5.8% in the simulated head and neck plan. Film measurements showed good agreement, with more than 92.5% of points passing a gamma value (3%/3 mm). From these results, the heterogeneous phantom should be useful for verification of IMPT by using a phantom‐specific HU‐relative stopping power conversion, fluence correction factor, and dose error estimation due to the effective point of the chamber.
Collapse
|
15
|
Improvements in pencil beam scanning proton therapy dose calculation accuracy in brain tumor cases with a commercial Monte Carlo algorithm. Phys Med Biol 2018; 63:145016. [PMID: 29726402 DOI: 10.1088/1361-6560/aac279] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A commercial Monte Carlo (MC) algorithm (RayStation version 6.0.024) for the treatment of brain tumors with pencil beam scanning (PBS) proton therapy is validated and compared via measurements and analytical calculations in clinically realistic scenarios. For the measurements a 2D ion chamber array detector (MatriXX PT) was placed underneath the following targets: (1) an anthropomorphic head phantom (with two different thicknesses) and (2) a biological sample (i.e. half a lamb's head). In addition, we compared the MC dose engine versus the RayStation pencil beam (PB) algorithm clinically implemented so far, in critical conditions such as superficial targets (i.e. in need of a range shifter (RS)), different air gaps, and gantry angles to simulate both orthogonal and tangential beam arrangements. For every plan the PB and MC dose calculations were compared to measurements using a gamma analysis metrics (3%, 3 mm). For the head phantom the gamma passing rate (GPR) was always >96% and on average >99% for the MC algorithm; the PB algorithm had a GPR of ⩽90% for all the delivery configurations with a single slab (apart 95% GPR from the gantry of 0° and small air gap) and in the case of two slabs of the head phantom the GPR was >95% only in the case of small air gaps for all three (0°, 45°, and 70°) simulated beam gantry angles. Overall the PB algorithm tends to overestimate the dose to the target (up to 25%) and underestimate the dose to the organ at risk (up to 30%). We found similar results (but a bit worse for the PB algorithm) for the two targets of the lamb's head where only two beam gantry angles were simulated. Our results suggest that in PBS proton therapy a range shifter (RS) needs to be used with caution when planning a treatment with an analytical algorithm due to potentially great discrepancies between the planned dose and the dose delivered to the patient, including in the case of brain tumors where this issue could be underestimated. Our results also suggest that a MC evaluation of the dose has to be performed every time the RS is used and, mostly, when it is used with large air gaps and beam directions tangential to the patient surface.
Collapse
|
16
|
Efficient double-scattering proton therapy with a patient-specific bolus. Phys Med 2018; 50:1-6. [PMID: 29891088 PMCID: PMC10865432 DOI: 10.1016/j.ejmp.2018.05.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/29/2017] [Revised: 05/01/2018] [Accepted: 05/03/2018] [Indexed: 11/29/2022] Open
Abstract
PURPOSE Passive scattering proton radiotherapy utilizes beam-specific compensators to shape the dose to the distal end of the tumor target. These compensators typically require therapists to enter the treatment room to mount between beams. This study investigates a novel approach that utilizes a single patient-specific bolus to accomplish the role of multi-field compensators to improve the efficiency of the treatment delivery. METHODS Ray-tracing from the proton virtual source was used to convert the beam-specific compensators (mounted on the gantry nozzle) into an equivalent bolus thickness on the patient surface. The field bolus contours were combined to create a single bolus. A 3D acrylic bolus was milled for a head phantom. The dose distribution of the compensator plan was compared to the bolus plan using 3D Gamma analysis and film measurements. Boluses for two clinical patients were also designed. RESULTS The calculated phantom dose distribution of the original proton compensator plan was shown to be equivalent to the plan with the surface bolus. Film irradiations with the proton bolus also confirmed the dosimetric equivalence of the two techniques. The dose distribution equivalency of the bolus plans for the clinical patients were demonstrated. CONCLUSIONS We presented a novel approach that uses a single patient-specific bolus to replace patient compensators during passive scattering proton delivery. This approach has the potential to reduce the treatment time, the compensator manufacturing costs, the risk of potential collision between the compensator and the patient/couch, and the waste of compensator material.
Collapse
|
17
|
Experimental validation of a 4D dose calculation routine for pencil beam scanning proton therapy. Z Med Phys 2018; 28:121-133. [DOI: 10.1016/j.zemedi.2017.07.005] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Revised: 06/12/2017] [Accepted: 07/25/2017] [Indexed: 12/15/2022]
|
18
|
Experimental validation of a deforming grid 4D dose calculation for PBS proton therapy. ACTA ACUST UNITED AC 2018; 63:055005. [DOI: 10.1088/1361-6560/aaad1e] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
19
|
|
20
|
Sensitivity of a prompt-gamma slit-camera to detect range shifts for proton treatment verification. Radiother Oncol 2017; 125:534-540. [DOI: 10.1016/j.radonc.2017.10.013] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 09/30/2017] [Accepted: 10/10/2017] [Indexed: 10/18/2022]
|
21
|
Review of technologies and procedures of clinical dosimetry for scanned ion beam radiotherapy. Phys Med 2017; 43:79-99. [DOI: 10.1016/j.ejmp.2017.10.013] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/30/2017] [Revised: 09/23/2017] [Accepted: 10/18/2017] [Indexed: 12/17/2022] Open
|
22
|
Treatment log files as a tool to identify treatment plan sensitivity to inaccuracies in scanned proton beam delivery. Radiother Oncol 2017; 125:514-519. [PMID: 29054379 DOI: 10.1016/j.radonc.2017.09.037] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2017] [Revised: 09/26/2017] [Accepted: 09/27/2017] [Indexed: 10/18/2022]
Abstract
Dose distributions delivered at Gantry 2 at the Paul Scherrer Institut (PSI) can be reconstructed on the patient anatomy based on machine log files. With the present work, the dependency of the log file calculation on the planning optimization technique and on other planning parameters, such as field direction and tumour size, has been investigated. Interestingly, and despite the typically higher modulation of Intensity Modulated Proton Therapy (IMPT) plans, the results for both Single Field Uniform Distribution and IMPT approaches have been found to be similar. In addition, complex fields with steep in-field dose gradients, such as Simultaneous Integrated Boost, and with couch movements in between the delivery, also resulted in good agreement between planned and reconstructed doses. Nevertheless, highly modulated plans can have regions of larger local dose deviations and attention should therefore be paid during the planning stage to the location of isolated, highly weighted pencil beams. We propose also, that further effort should be invested in order to predict field robustness to delivery fluctuations before the clinical delivery of the plan as part of the plan specific Quality Assurance.
Collapse
|
23
|
Fred: a GPU-accelerated fast-Monte Carlo code for rapid treatment plan recalculation in ion beam therapy. ACTA ACUST UNITED AC 2017; 62:7482-7504. [DOI: 10.1088/1361-6560/aa8134] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
24
|
Effect of Anatomic Changes on Pencil Beam Scanned Proton Dose Distributions for Cranial and Extracranial Tumors. Int J Radiat Oncol Biol Phys 2017; 97:616-623. [DOI: 10.1016/j.ijrobp.2016.11.013] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2016] [Revised: 10/31/2016] [Accepted: 11/08/2016] [Indexed: 10/20/2022]
|
25
|
An anthropomorphic breathing phantom of the thorax for testing new motion mitigation techniques for pencil beam scanning proton therapy. Phys Med Biol 2017; 62:2486-2504. [DOI: 10.1088/1361-6560/62/6/2486] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
26
|
Abstract
Proton therapy, especially in the form of pencil beam scanning (PBS), allows for the delivery of highly conformal dose distributions for complex tumor geometries. However, due to scattering of protons inside the patient, lateral dose gradients cannot be arbitrarily steep, which is of importance in cases with organs at risk (OARs) in close proximity to, or overlapping with, planning target volumes (PTVs). In the PBS approach, physical pencil beams are planned using a regular grid orthogonal to the beam direction. In this work, we propose an alternative to this commonly used approach where pencil beams are placed on an irregular grid along concentric paths based on the target contour. Contour driven pencil beam placement is expected to improve dose confirmation by allowing the optimizer to best enhance the penumbra of irregularly shaped targets using edge enhancement. Its effectiveness has been shown to improve dose confirmation to the target volume and reduce doses to OARs in head-and-neck planning studies. Furthermore, the deliverability of such plans, as well as the dosimetric improvements over conventional grid-based plans, have been confirmed in first phantom based verifications.
Collapse
|
27
|
Technical Note: Radiological properties of tissue surrogates used in a multimodality deformable pelvic phantom for MR-guided radiotherapy. Med Phys 2016; 43:908-16. [DOI: 10.1118/1.4939874] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
28
|
Characterization and validation of a Monte Carlo code for independent dose calculation in proton therapy treatments with pencil beam scanning. Phys Med Biol 2015; 60:8601-19. [PMID: 26501569 DOI: 10.1088/0031-9155/60/21/8601] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We propose a method of creating and validating a Monte Carlo (MC) model of a proton Pencil Beam Scanning (PBS) machine using only commissioning measurements and avoiding the nozzle modeling. Measurements with a scintillating screen coupled with a CCD camera, ionization chamber and a Faraday Cup were used to model the beam in TOPAS without using any machine parameter information but the virtual source distance from the isocenter. Then the model was validated on simple Spread Out Bragg Peaks (SOBP) delivered in water phantom and with six realistic clinical plans (many involving 3 or more fields) on an anthropomorphic phantom. In particular the behavior of the moveable Range Shifter (RS) feature was investigated and its modeling has been proposed. The gamma analysis (3%,3 mm) was used to compare MC, TPS (XiO-ELEKTA) and measured 2D dose distributions (using radiochromic film). The MC modeling proposed here shows good results in the validation phase, both for simple irradiation geometry (SOBP in water) and for modulated treatment fields (on anthropomorphic phantoms). In particular head lesions were investigated and both MC and TPS data were compared with measurements. Treatment plans with no RS always showed a very good agreement with both of them (γ-Passing Rate (PR) > 95%). Treatment plans in which the RS was needed were also tested and validated. For these treatment plans MC results showed better agreement with measurements (γ-PR > 93%) than the one coming from TPS (γ-PR < 88%). This work shows how to simplify the MC modeling of a PBS machine for proton therapy treatments without accounting for any hardware components and proposes a more reliable RS modeling than the one implemented in our TPS. The validation process has shown how this code is a valid candidate for a completely independent treatment plan dose calculation algorithm. This makes the code an important future tool for the patient specific QA verification process.
Collapse
|
29
|
Benchmarking of a treatment planning system for spot scanning proton therapy: comparison and analysis of robustness to setup errors of photon IMRT and proton SFUD treatment plans of base of skull meningioma. Med Phys 2015; 41:111710. [PMID: 25370624 DOI: 10.1118/1.4897571] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE Base of skull meningioma can be treated with both intensity modulated radiation therapy (IMRT) and spot scanned proton therapy (PT). One of the main benefits of PT is better sparing of organs at risk, but due to the physical and dosimetric characteristics of protons, spot scanned PT can be more sensitive to the uncertainties encountered in the treatment process compared with photon treatment. Therefore, robustness analysis should be part of a comprehensive comparison between these two treatment methods in order to quantify and understand the sensitivity of the treatment techniques to uncertainties. The aim of this work was to benchmark a spot scanning treatment planning system for planning of base of skull meningioma and to compare the created plans and analyze their robustness to setup errors against the IMRT technique. METHODS Plans were produced for three base of skull meningioma cases: IMRT planned with a commercial TPS [Monaco (Elekta AB, Sweden)]; single field uniform dose (SFUD) spot scanning PT produced with an in-house TPS (PSI-plan); and SFUD spot scanning PT plan created with a commercial TPS [XiO (Elekta AB, Sweden)]. A tool for evaluating robustness to random setup errors was created and, for each plan, both a dosimetric evaluation and a robustness analysis to setup errors were performed. RESULTS It was possible to create clinically acceptable treatment plans for spot scanning proton therapy of meningioma with a commercially available TPS. However, since each treatment planning system uses different methods, this comparison showed different dosimetric results as well as different sensitivities to setup uncertainties. The results confirmed the necessity of an analysis tool for assessing plan robustness to provide a fair comparison of photon and proton plans. CONCLUSIONS Robustness analysis is a critical part of plan evaluation when comparing IMRT plans with spot scanned proton therapy plans.
Collapse
|
30
|
Dosimetric robustness against setup errors in charged particle radiotherapy of skull base tumors. Radiat Oncol 2014; 9:279. [PMID: 25477197 PMCID: PMC4263024 DOI: 10.1186/s13014-014-0279-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2014] [Accepted: 09/23/2014] [Indexed: 02/08/2023] Open
Abstract
Background It is expected that physical dose deposition properties render charged particle dose distributions sensitive to targeting uncertainties. Purpose of this work was to investigate the robustness of scanned-beam particle therapy plans against setup errors for different optimization modalities, beam setups and ion species. Material and methods For 15 patients with skull base tumors, localized in regions of severe tissue density heterogeneity, scanned lateral-opposed-beam treatment plans were prepared with the treatment planning system TRiP98, employing different optimization settings (single- and multiple-field modulation) and ion species (carbon ions and protons). For 10 of the patients, additional plans were prepared with individually selected beam setups, aiming at avoiding severe tissue heterogeneities. Subsequently, multiple rigid positioning errors of magnitude 1–2 mm (i.e. within planning target expansion) were simulated by introducing a shift of the irradiation fields with respect to the computed tomography (CT) data and recomputing the plans. Results In presence of shifts, in carbon ion plans using a lateral-opposed beam setup and fulfilling clinical healthy tissue dose constraints, the median reduction in CTV V95% was up to 0.7 percentage points (pp) and 3.5 pp, for shifts of magnitude 1 mm and 2 mm respectively, however, in individual cases, the reduction reached 5.1 pp and 9.7 pp. In the corresponding proton plans similar median CTV V95% reductions of up to 0.9 pp (1 mm error) and 3.4 pp (2 mm error) were observed, with respective individual-case reductions of at most 3.2 pp and 11.7 pp. Unconstrained plans offered slightly higher coverage values, while no relevant differences were observed between different field modulation methods. Individually selected beam setups had a visible dosimetric advantage over lateral-opposed beams, for both particle species. While carbons provided more conformal plans and generally more advantageous absolute dose values, in presence of setup errors, protons showed greater dosimetric stability, in most of the investigated scenarios. Conclusion Residual patient setup errors may lead to substantial dose perturbation in scanned-beam particle therapy of skull base tumors, which cannot be dealt with by planning target expansion alone. Choice of irradiation directions avoiding extreme density heterogeneities can improve plan stability against such delivery-time uncertainties.
Collapse
|
31
|
The effect of surgical titanium rods on proton therapy delivered for cervical bone tumors: experimental validation using an anthropomorphic phantom. Phys Med Biol 2014; 59:7181-94. [DOI: 10.1088/0031-9155/59/23/7181] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
32
|
Dosimetric effects of residual uncertainties in carbon ion treatment of head chordoma. Radiother Oncol 2014; 113:66-71. [DOI: 10.1016/j.radonc.2014.08.001] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Revised: 07/19/2014] [Accepted: 08/02/2014] [Indexed: 01/03/2023]
|
33
|
Evaluating IMRT and VMAT dose accuracy: practical examples of failure to detect systematic errors when applying a commonly used metric and action levels. Med Phys 2014; 40:111722. [PMID: 24320430 DOI: 10.1118/1.4826166] [Citation(s) in RCA: 155] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE This study (1) examines a variety of real-world cases where systematic errors were not detected by widely accepted methods for IMRT/VMAT dosimetric accuracy evaluation, and (2) drills-down to identify failure modes and their corresponding means for detection, diagnosis, and mitigation. The primary goal of detailing these case studies is to explore different, more sensitive methods and metrics that could be used more effectively for evaluating accuracy of dose algorithms, delivery systems, and QA devices. METHODS The authors present seven real-world case studies representing a variety of combinations of the treatment planning system (TPS), linac, delivery modality, and systematic error type. These case studies are typical to what might be used as part of an IMRT or VMAT commissioning test suite, varying in complexity. Each case study is analyzed according to TG-119 instructions for gamma passing rates and action levels for per-beam and/or composite plan dosimetric QA. Then, each case study is analyzed in-depth with advanced diagnostic methods (dose profile examination, EPID-based measurements, dose difference pattern analysis, 3D measurement-guided dose reconstruction, and dose grid inspection) and more sensitive metrics (2% local normalization/2 mm DTA and estimated DVH comparisons). RESULTS For these case studies, the conventional 3%/3 mm gamma passing rates exceeded 99% for IMRT per-beam analyses and ranged from 93.9% to 100% for composite plan dose analysis, well above the TG-119 action levels of 90% and 88%, respectively. However, all cases had systematic errors that were detected only by using advanced diagnostic techniques and more sensitive metrics. The systematic errors caused variable but noteworthy impact, including estimated target dose coverage loss of up to 5.5% and local dose deviations up to 31.5%. Types of errors included TPS model settings, algorithm limitations, and modeling and alignment of QA phantoms in the TPS. Most of the errors were correctable after detection and diagnosis, and the uncorrectable errors provided useful information about system limitations, which is another key element of system commissioning. CONCLUSIONS Many forms of relevant systematic errors can go undetected when the currently prevalent metrics for IMRT∕VMAT commissioning are used. If alternative methods and metrics are used instead of (or in addition to) the conventional metrics, these errors are more likely to be detected, and only once they are detected can they be properly diagnosed and rooted out of the system. Removing systematic errors should be a goal not only of commissioning by the end users but also product validation by the manufacturers. For any systematic errors that cannot be removed, detecting and quantifying them is important as it will help the physicist understand the limits of the system and work with the manufacturer on improvements. In summary, IMRT and VMAT commissioning, along with product validation, would benefit from the retirement of the 3%/3 mm passing rates as a primary metric of performance, and the adoption instead of tighter tolerances, more diligent diagnostics, and more thorough analysis.
Collapse
|
34
|
Adequate margin definition for scanned particle therapy in the incidence of intrafractional motion. Phys Med Biol 2013; 58:6079-94. [DOI: 10.1088/0031-9155/58/17/6079] [Citation(s) in RCA: 79] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
35
|
Dosimetry in brain tumor phantom at 15 MV 3D conformal radiation therapy. Radiat Oncol 2013; 8:168. [PMID: 23829593 PMCID: PMC3729429 DOI: 10.1186/1748-717x-8-168] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2013] [Accepted: 06/18/2013] [Indexed: 11/17/2022] Open
Abstract
Glioblastoma multiforme (GBM) is the most common, aggressive, highly malignant and infiltrative of all brain tumors with low rate of control. The main goal of this work was to evaluate the spatial dose distribution into a GBM simulator inside a head phantom exposed to a 15 MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Such phantom holds the following synthetic structures: brain and spinal cord, skull, cervical and thoracic vertebrae, jaw, hyoid bone, laryngeal cartilages, head and neck muscles and skin. Computer tomography (CT) of the simulator was taken, capturing a set of contrasted references. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples at coronal, sagittal-anterior and sagittal-posterior positions, inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, measured at coronal section, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. And, as final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols.
Collapse
|
36
|
Multifield optimization intensity-modulated proton therapy (MFO-IMPT) for prostate cancer: Robustness analysis through simulation of rotational and translational alignment errors. Med Dosim 2013; 38:344-50. [PMID: 23747223 DOI: 10.1016/j.meddos.2013.03.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2012] [Accepted: 03/08/2013] [Indexed: 10/26/2022]
Abstract
To evaluate the dosimetric consequences of rotational and translational alignment errors in patients receiving intensity-modulated proton therapy with multifield optimization (MFO-IMPT) for prostate cancer. Ten control patients with localized prostate cancer underwent treatment planning for MFO-IMPT. Rotational and translation errors were simulated along each of 3 axes: anterior-posterior (A-P), superior-inferior (S-I), and left-right. Clinical target-volume (CTV) coverage remained high with all alignment errors simulated. Rotational errors did not result in significant rectum or bladder dose perturbations. Translational errors resulted in larger dose perturbations to the bladder and rectum. Perturbations in rectum and bladder doses were minimal for rotational errors and larger for translational errors. Rectum V45 and V70 increased most with A-P misalignment, whereas bladder V45 and V70 changed most with S-I misalignment. The bladder and rectum V45 and V70 remained acceptable even with extreme alignment errors. Even with S-I and A-P translational errors of up to 5mm, the dosimetric profile of MFO-IMPT remained favorable. MFO-IMPT for localized prostate cancer results in robust coverage of the CTV without clinically meaningful dose perturbations to normal tissue despite extreme rotational and translational alignment errors.
Collapse
|
37
|
Application of failure mode and effects analysis to treatment planning in scanned proton beam radiotherapy. Radiat Oncol 2013; 8:127. [PMID: 23705626 PMCID: PMC3679803 DOI: 10.1186/1748-717x-8-127] [Citation(s) in RCA: 62] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2012] [Accepted: 05/19/2013] [Indexed: 11/21/2022] Open
Abstract
Background A multidisciplinary and multi-institutional working group applied the Failure Mode and Effects Analysis (FMEA) approach to the actively scanned proton beam radiotherapy process implemented at CNAO (Centro Nazionale di Adroterapia Oncologica), aiming at preventing accidental exposures to the patient. Methods FMEA was applied to the treatment planning stage and consisted of three steps: i) identification of the involved sub-processes; ii) identification and ranking of the potential failure modes, together with their causes and effects, using the risk probability number (RPN) scoring system, iii) identification of additional safety measures to be proposed for process quality and safety improvement. RPN upper threshold for little concern of risk was set at 125. Results Thirty-four sub-processes were identified, twenty-two of them were judged to be potentially prone to one or more failure modes. A total of forty-four failure modes were recognized, 52% of them characterized by an RPN score equal to 80 or higher. The threshold of 125 for RPN was exceeded in five cases only. The most critical sub-process appeared related to the delineation and correction of artefacts in planning CT data. Failures associated to that sub-process were inaccurate delineation of the artefacts and incorrect proton stopping power assignment to body regions. Other significant failure modes consisted of an outdated representation of the patient anatomy, an improper selection of beam direction and of the physical beam model or dose calculation grid. The main effects of these failures were represented by wrong dose distribution (i.e. deviating from the planned one) delivered to the patient. Additional strategies for risk mitigation, easily and immediately applicable, consisted of a systematic information collection about any known implanted prosthesis directly from each patient and enforcing a short interval time between CT scan and treatment start. Moreover, (i) the investigation of dedicated CT image reconstruction algorithms, (ii) further evaluation of treatment plan robustness and (iii) implementation of independent methods for dose calculation (such as Monte Carlo simulations) may represent novel solutions to increase patient safety. Conclusions FMEA is a useful tool for prospective evaluation of patient safety in proton beam radiotherapy. The application of this method to the treatment planning stage lead to identify strategies for risk mitigation in addition to the safety measures already adopted in clinical practice.
Collapse
|
38
|
Accuracy of robotic patient positioners used in ion beam therapy. Radiat Oncol 2013; 8:124. [PMID: 23692666 PMCID: PMC3749753 DOI: 10.1186/1748-717x-8-124] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Accepted: 05/10/2013] [Indexed: 12/04/2022] Open
Abstract
Background In this study we investigate the accuracy of industrial six axes robots employed for patient positioning at the Heidelberg Ion Beam Therapy Center. Methods In total 1018 patient setups were monitored with a laser tracker and subsequently analyzed. The measurements were performed in the two rooms with a fixed horizontal beam line. Both, the 3d translational errors and the rotational errors around the three table axes were determined. Results For the first room the 3d error was smaller than 0.72 mm in 95 percent of all setups. The standard deviation of the rotational errors was at most 0.026° for all axes. For the second room Siemens implemented an improved approach strategy to the final couch positions. The 95 percent quantile of the 3d error could in this room be reduced to 0.53 mm; the standard deviation of the rotational errors was also at most 0.026°. Conclusions Robots are very flexible tools for patient positioning in six degrees of freedom. This study proved that the robots are able to achieve clinically acceptable accuracy in real patient setups, too.
Collapse
|
39
|
Dosimetric accuracy assessment of a treatment plan verification system for scanned proton beam radiotherapy: one-year experimental results and Monte Carlo analysis of the involved uncertainties. Phys Med Biol 2013; 58:3837-47. [DOI: 10.1088/0031-9155/58/11/3837] [Citation(s) in RCA: 60] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
40
|
Mapping motion from 4D-MRI to 3D-CT for use in 4D dose calculations: A technical feasibility study. Med Phys 2013; 40:061702. [DOI: 10.1118/1.4801914] [Citation(s) in RCA: 84] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
41
|
Spencer–Attix water/medium stopping-power ratios for the dosimetry of proton pencil beams. Phys Med Biol 2013; 58:2509-22. [DOI: 10.1088/0031-9155/58/8/2509] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
42
|
Advantages and limitations of the ‘worst case scenario’ approach in IMPT treatment planning. Phys Med Biol 2013; 58:1323-39. [DOI: 10.1088/0031-9155/58/5/1323] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
43
|
Abstract
The goal of radiotherapy is to achieve uniform target coverage while sparing normal tissue. In proton therapy, the same sources of geometric uncertainty are present as in conventional radiotherapy. However, an important and fundamental difference in proton therapy is that protons have a finite range, highly dependent on the electron density of the material they are traversing, resulting in a steep dose gradient at the distal edge of the Bragg peak. Therefore, an accurate knowledge of the sources and magnitudes of the uncertainties affecting the proton range is essential for producing plans which are robust to these uncertainties. This review describes the current knowledge of the geometric uncertainties and discusses their impact on proton dose plans. The need for patient-specific validation is essential and in cases of complex intensity-modulated proton therapy plans the use of a planning target volume (PTV) may fail to ensure coverage of the target. In cases where a PTV cannot be used, other methods of quantifying plan quality have been investigated. A promising option is to incorporate uncertainties directly into the optimisation algorithm. A further development is the inclusion of robustness into a multicriteria optimisation framework, allowing a multi-objective Pareto optimisation function to balance robustness and conformity. The question remains as to whether adaptive therapy can become an integral part of a proton therapy, to allow re-optimisation during the course of a patient's treatment. The challenge of ensuring that plans are robust to range uncertainties in proton therapy remains, although these methods can provide practical solutions.
Collapse
|
44
|
Is there a single spot size and grid for intensity modulated proton therapy? Simulation of head and neck, prostate and mesothelioma cases. Med Phys 2012; 39:1298-308. [DOI: 10.1118/1.3683640] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|