Yan S, Depauw N, Adams J, Gorissen BL, Shih HA, Flanz J, Bortfeld T, Lu HM. Technical Note: Does the greater power of pencil beam scanning reduce the need for a proton gantry? A study of head-and-neck and brain tumors. Med Phys 2021; 49:813-824. [PMID: 34919736 DOI: 10.1002/mp.15409] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Revised: 11/05/2021] [Accepted: 11/22/2021] [Indexed: 11/08/2022] Open
Abstract
PURPOSE Proton therapy systems without a gantry can be more compact and less expensive in terms of capital cost, and therefore more available to a larger patient population. Would the advances in pencil beam scanning and robotics make gantry-less treatment possible? In this study, we explore if high-quality treatment plans can be obtained without a gantry. METHODS AND MATERIALS We recently showed that proton treatments with the patient in an upright position may be feasible with a new soft robotic immobilization device and imaging which enables multiple possible patient orientations during a treatment. In this study, we evaluate if this new treatment geometry could enable high quality treatment plans without a gantry. We created pencil beam scanning (PBS) treatment plans for seven patients with head-and-neck or brain tumors. Each patient was planned with two scenarios: one with a gantry with the patient in supine position and the other with a gantry-less fixed horizontal beam-line with the patient sitting upright. For the treatment plans, dose-volume-histograms (DVHs), target homogeneity index (HI), mean dose, are reported. A robustness analysis of one plan was performed with 2.5 mm setup errors and 3.5% range uncertainties with nine scenarios. RESULTS Most of the PBS-gantry-less plans had similar target HI and OAR mean dose as compared to PBS-gantry plans, and similar robustness with respect to range uncertainties and setup errors. CONCLUSIONS Pencil beam scanning provides sufficient power to deliver high quality treatment plans without requiring a gantry for head-and-neck or brain tumors. In combination with the development of the new positioning and immobilization methods required to support this treatment geometry, this work suggests the feasibility of further development of a compact proton therapy system with a fixed horizontal beam-line to treat patients in sitting and reclined positions. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Susu Yan
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School
| | - Nicolas Depauw
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School
| | - Judith Adams
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School
| | - Bram L Gorissen
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School
| | - Helen A Shih
- Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School
| | - Jay Flanz
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School
| | - Thomas Bortfeld
- Division of Radiation Biophysics, Department of Radiation Oncology, Massachusetts General Hospital and Harvard Medical School
| | - Hsiao-Ming Lu
- Hefei Ion Medical Center and Ion Medical Research Institute, University of Science and Technology of China, Hefei, China
| |
Collapse
|
2
|
Hua CH, Mascia AE, Servalli E, Lomax AJ, Seiersen K, Ulin K. Advances in radiotherapy technology for pediatric cancer patients and roles of medical physicists: COG and SIOP Europe perspectives. Pediatr Blood Cancer 2021; 68 Suppl 2:e28344. [PMID: 33818892 PMCID: PMC8030241 DOI: 10.1002/pbc.28344] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 03/27/2020] [Accepted: 04/02/2020] [Indexed: 11/11/2022]
Abstract
Over the last two decades, rapid technological advances have dramatically changed radiation delivery to children with cancer, enabling improved normal-tissue sparing. This article describes recent advances in photon and proton therapy technologies, image-guided patient positioning, motion management, and adaptive therapy that are relevant to pediatric cancer patients. For medical physicists who are at the forefront of realizing the promise of technology, challenges remain with respect to ensuring patient safety as new technologies are implemented with increasing treatment complexity. The contributions of medical physicists to meeting these challenges in daily practice, in the conduct of clinical trials, and in pediatric oncology cooperative groups are highlighted. Representing the perspective of the physics committees of the Children's Oncology Group (COG) and the European Society for Paediatric Oncology (SIOP Europe), this paper provides recommendations regarding the safe delivery of pediatric radiotherapy. Emerging innovations are highlighted to encourage pediatric applications with a view to maximizing the therapeutic ratio.
Collapse
Affiliation(s)
- Chia-ho Hua
- Department of Radiation Oncology, St. Jude Children’s Research Hospital, Memphis, Tennessee, USA
| | - Anthony E. Mascia
- Department of Radiation Oncology, University of Cincinnati, Cincinnati, Ohio, USA
| | - Enrica Servalli
- Department of Radiotherapy, University Medical Center Utrecht, The Netherlands
| | - Antony J. Lomax
- Center for Proton Therapy, Paul Scherrer Institute, PSI Villigen, Switzerland
| | | | - Kenneth Ulin
- Department of Radiation Oncology, University of Massachusetts, Worcester, Massachusetts, USA
| |
Collapse
|
3
|
Giantsoudi D, Adams J, MacDonald S, Paganetti H. Can differences in linear energy transfer and thus relative biological effectiveness compromise the dosimetric advantage of intensity-modulated proton therapy as compared to passively scattered proton therapy? Acta Oncol 2018; 57:1259-1264. [PMID: 29726722 DOI: 10.1080/0284186x.2018.1468090] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Abstract
PURPOSE To investigate the effect of differences in linear energy transfer (LET) and thus the relative biological effectiveness (RBE) between passively scattered proton therapy (PS) and pencil-beam scanning intensity-modulated proton therapy (IMPT). METHODS IMPT treatment plans were generated for six ependymoma patients, originally treated with PS, using the original plan's computed tomography image sets and beam directions, and its dose-volume values as optimization constraints. Two beam spot sizes and both single-field optimization (SFO) and multi-field optimization (MFO) techniques were used for each patient. Three-dimensional variable-RBE-weighted dose distributions were computed, using Monte Carlo calculated dose and LET distributions, and a linear dose and LET-based RBE model, and were compared between the two delivery methods. RESULTS Increased target dose coverage and decreased mean and maximum dose to the OARs was achieved with IMPT compared to PS, for constant RBE value of 1.1. Nevertheless, the maximum variable-RBE-weighted dose to the brainstem, was increased up to 6% for the IMPT plans compared to the corresponding PS plans. CONCLUSIONS IMPT can be dosimetrically superior to PS for ependymoma patients. However, caution should be exercised so that the increased dose conformity is not counteracted by an increase in radiobiological effect in adjacent critical structures.
Collapse
Affiliation(s)
- Drosoula Giantsoudi
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| | - Judith Adams
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| | - Shannon MacDonald
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| | - Harald Paganetti
- Department of Radiation Oncology, Massachusetts General Hospital, Boston, MA, USA
| |
Collapse
|
4
|
Intensity-modulated radiotherapy for whole pelvis irradiation in prostate cancer: A dosimetric and plan robustness study between photons and protons. Tech Innov Patient Support Radiat Oncol 2018; 6:11-19. [PMID: 32095573 PMCID: PMC7033791 DOI: 10.1016/j.tipsro.2018.02.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2017] [Revised: 02/16/2018] [Accepted: 02/22/2018] [Indexed: 11/22/2022] Open
Abstract
Purpose To evaluate the dosimetric impact and plan robustness of using Pencil Beam Scanning (PBS) in patients that requires prophylactic pelvic lymph nodes (PLNs) irradiation for prostate cancer. Material and methods Five intermediate to high-risk prostate patients previously treated using volumetric modulated arc therapy (VMAT), were selected for this study. Comparative proton radiotherapy plans were generated, where a three-field intensity modulated proton therapy (IMPT) plan was for the phase 1 planning target volume (PTV1) with PLNs. A technique with two posterior oblique fields using single field uniform dose (SFUD) was used for phase 2 (PTV2) volume, that comprises of the prostate and proximal seminal vesicles (Pro + proxSVs). Plan evaluation was performed on PTV coverage and dose to the organs at risk (OARs) using VMAT plans as a baseline (BL). Robust analysis on clinical target volume (CTV) coverage for the PBS plans was simulated with a 3 and 5 mm setup errors and a 3.5% range uncertainty. Results For target coverage, PTV1 and PTV2 showed negligible differences with a comparable homogeneity index (HI) values for both modalities. Proton plans produced a statistically significant lower mean dose to the bladder (32.5 Gy(RBE) vs. 46.5 Gy) and rectum (33.6 Gy(RBE) vs. 42.7 Gy). Dose to the bladder and rectum was equivalent at the high dose region. For the bowel cavity, the mean dose for proton plans were 45% lower compared to VMAT plans. Similarly, proton plans were able to achieve an overall reduction in integral dose for both treatment phase. CTV coverage remained high with all the simulated setup and range errors. Conclusions Proposed beam geometries for PTV1 and PTV2 proton plans presented good treatment accuracy with similar target coverage as the VMAT plans. Better sparing of OARs was achieved at the low-medium dose region for the proton plans.
Collapse
|
5
|
Niedzielski JS, Yang J, Mohan R, Titt U, Mirkovic D, Stingo F, Liao Z, Gomez DR, Martel MK, Briere TM, Court LE. Differences in Normal Tissue Response in the Esophagus Between Proton and Photon Radiation Therapy for Non-Small Cell Lung Cancer Using In Vivo Imaging Biomarkers. Int J Radiat Oncol Biol Phys 2017; 99:1013-1020. [PMID: 29063837 DOI: 10.1016/j.ijrobp.2017.07.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2017] [Revised: 06/26/2017] [Accepted: 07/01/2017] [Indexed: 01/21/2023]
Abstract
PURPOSE To determine whether there exists any significant difference in normal tissue toxicity between intensity modulated radiation therapy (IMRT) or proton therapy for the treatment of non-small cell lung cancer. METHODS AND MATERIALS A total of 134 study patients (n=49 treated with proton therapy, n=85 with IMRT) treated in a randomized trial had a previously validated esophageal toxicity imaging biomarker, esophageal expansion, quantified during radiation therapy, as well as esophagitis grade (Common Terminology Criteria for Adverse Events version 3.0), on a weekly basis during treatment. Differences between the 2 modalities were statically analyzed using the imaging biomarker metric value (Kruskal-Wallis analysis of variance), as well as the incidence and severity of esophagitis grade (χ2 and Fisher exact tests, respectively). The dose-response of the imaging biomarker was also compared between modalities using esophageal equivalent uniform dose, as well as delivered dose to an isotropic esophageal subvolume. RESULTS No statistically significant difference in the distribution of esophagitis grade, the incidence of grade ≥3 esophagitis (15 and 11 patients treated with IMRT and proton therapy, respectively), or the esophageal expansion imaging biomarker between cohorts (P>.05) was found. The distribution of imaging biomarker metric values had similar distributions between treatment arms, despite a slightly higher dose volume in the proton arm (P>.05). Imaging biomarker dose-response was similar between modalities for dose quantified as esophageal equivalent uniform dose and delivered esophageal subvolume dose. Regardless of treatment modality, there was high variability in imaging biomarker response, as well as esophagitis grade, for similar esophageal doses between patients. CONCLUSIONS There was no significant difference in esophageal toxicity from either proton- or photon-based radiation therapy as quantified by esophagitis grade or the esophageal expansion imaging biomarker.
Collapse
Affiliation(s)
- Joshua S Niedzielski
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas.
| | - Jinzhong Yang
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas
| | - Radhe Mohan
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas
| | - Uwe Titt
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas
| | - Dragan Mirkovic
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas
| | - Francesco Stingo
- Department of Statistics, Computer Science, Applications "G. Parenti," University of Florence, Florence, Italy
| | - Zhongxing Liao
- Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, Texas
| | - Daniel R Gomez
- Department of Radiation Oncology, The University of Texas M. D. Anderson Cancer Center, Houston, Texas
| | - Mary K Martel
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas
| | - Tina M Briere
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas
| | - Laurence E Court
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas; University of Texas-Houston Health Science Center, Graduate School of Biomedical Science, Houston, Texas
| |
Collapse
|
6
|
Innovative radiotherapy of sarcoma: Proton beam radiation. Eur J Cancer 2016; 62:112-23. [PMID: 27258968 DOI: 10.1016/j.ejca.2016.04.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2015] [Revised: 04/13/2016] [Accepted: 04/14/2016] [Indexed: 01/13/2023]
Abstract
This review on proton beam radiotherapy (PBT) focusses on an historical overview, cost-effectiveness, techniques, acute and late toxicities and clinical results of PBT for sarcoma patients. PBT has gained its place among the armamentarium of modern radiotherapy techniques. For selected patients, it can be cost-effective.
Collapse
|
7
|
Yan S, Lu HM, Flanz J, Adams J, Trofimov A, Bortfeld T. Reassessment of the Necessity of the Proton Gantry: Analysis of Beam Orientations From 4332 Treatments at the Massachusetts General Hospital Proton Center Over the Past 10 Years. Int J Radiat Oncol Biol Phys 2016; 95:224-233. [DOI: 10.1016/j.ijrobp.2015.09.033] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2015] [Revised: 08/14/2015] [Accepted: 09/21/2015] [Indexed: 01/19/2023]
|
8
|
Chen CC, Chang C, Moyers MF, Gao M, Mah D. Technical Note: Spot characteristic stability for proton pencil beam scanning. Med Phys 2016; 43:777-82. [PMID: 26843240 DOI: 10.1118/1.4939663] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE The spot characteristics for proton pencil beam scanning (PBS) were measured and analyzed over a 16 month period, which included one major site configuration update and six cyclotron interventions. The results provide a reference to establish the quality assurance (QA) frequency and tolerance for proton pencil beam scanning. METHODS A simple treatment plan was generated to produce an asymmetric 9-spot pattern distributed throughout a field of 16 × 18 cm for each of 18 proton energies (100.0-226.0 MeV). The delivered fluence distribution in air was measured using a phosphor screen based CCD camera at three planes perpendicular to the beam line axis (x-ray imaging isocenter and up/down stream 15.0 cm). The measured fluence distributions for each energy were analyzed using in-house programs which calculated the spot sizes and positional deviations of the Gaussian shaped spots. RESULTS Compared to the spot characteristic data installed into the treatment planning system, the 16-month averaged deviations of the measured spot sizes at the isocenter plane were 2.30% and 1.38% in the IEC gantry x and y directions, respectively. The maximum deviation was 12.87% while the minimum deviation was 0.003%, both at the upstream plane. After the collinearity of the proton and x-ray imaging system isocenters was optimized, the positional deviations of the spots were all within 1.5 mm for all three planes. During the site configuration update, spot positions were found to deviate by 6 mm until the tuning parameters file was properly restored. CONCLUSIONS For this beam delivery system, it is recommended to perform a spot size and position check at least monthly and any time after a database update or cyclotron intervention occurs. A spot size deviation tolerance of <15% can be easily met with this delivery system. Deviations of spot positions were <2 mm at any plane up/down stream 15 cm from the isocenter.
Collapse
Affiliation(s)
| | - Chang Chang
- ProCure Treatment Center, Somerset, New Jersey 08873
| | - Michael F Moyers
- ProCure Treatment Center, Somerset, New Jersey 08873 and Shanghai Proton and Heavy Ion Center, Shanghai 201321, China
| | | | - Dennis Mah
- ProCure Treatment Center, Somerset, New Jersey 08873
| |
Collapse
|
9
|
Grosshans DR, Zhu XR, Melancon A, Allen PK, Poenisch F, Palmer M, McAleer MF, McGovern SL, Gillin M, DeMonte F, Chang EL, Brown PD, Mahajan A. Spot scanning proton therapy for malignancies of the base of skull: treatment planning, acute toxicities, and preliminary clinical outcomes. Int J Radiat Oncol Biol Phys 2014; 90:540-6. [PMID: 25304948 DOI: 10.1016/j.ijrobp.2014.07.005] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2014] [Revised: 06/30/2014] [Accepted: 07/03/2014] [Indexed: 11/30/2022]
Abstract
PURPOSE To describe treatment planning techniques and early clinical outcomes in patients treated with spot scanning proton therapy for chordoma or chondrosarcoma of the skull base. METHODS AND MATERIALS From June 2010 through August 2011, 15 patients were treated with spot scanning proton therapy for chordoma (n=10) or chondrosarcoma (n=5) at a single institution. Toxicity was prospectively evaluated and scored weekly and at all follow-up visits according to Common Terminology Criteria for Adverse Events, version 3.0. Treatment planning techniques and dosimetric data were recorded and compared with those of passive scattering plans created with clinically applicable dose constraints. RESULTS Ten patients were treated with single-field-optimized scanning beam plans and 5 with multifield-optimized intensity modulated proton therapy. All but 2 patients received a simultaneous integrated boost as well. The mean prescribed radiation doses were 69.8 Gy (relative biological effectiveness [RBE]; range, 68-70 Gy [RBE]) for chordoma and 68.4 Gy (RBE) (range, 66-70) for chondrosarcoma. In comparison with passive scattering plans, spot scanning plans demonstrated improved high-dose conformality and sparing of temporal lobes and brainstem. Clinically, the most common acute toxicities included fatigue (grade 2 for 2 patients, grade 1 for 8 patients) and nausea (grade 2 for 2 patients, grade 1 for 6 patients). No toxicities of grades 3 to 5 were recorded. At a median follow-up time of 27 months (range, 13-42 months), 1 patient had experienced local recurrence and a second developed distant metastatic disease. Two patients had magnetic resonance imaging-documented temporal lobe changes, and a third patient developed facial numbness. No other subacute or late effects were recorded. CONCLUSIONS In comparison to passive scattering, treatment plans for spot scanning proton therapy displayed improved high-dose conformality. Clinically, the treatment was well tolerated, and with short-term follow-up, disease control rates and toxicity profiles were favorable.
Collapse
Affiliation(s)
- David R Grosshans
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas.
| | - X Ronald Zhu
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Adam Melancon
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Pamela K Allen
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Falk Poenisch
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Matthew Palmer
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Mary Frances McAleer
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Susan L McGovern
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Michael Gillin
- Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Franco DeMonte
- Department of Neurosurgery, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Eric L Chang
- Department of Radiation Oncology, University of Southern California Keck School of Medicine, Los Angeles, California
| | - Paul D Brown
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| | - Anita Mahajan
- Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas
| |
Collapse
|
10
|
Rombi B, Timmermann B. Proton Beam Therapy for Pediatric Chordomas: State of the Art. Int J Part Ther 2014. [DOI: 10.14338/ijpt.13.00008.1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|