Iommi D, Hummel J, Figl ML. Evaluation of 3D ultrasound for image guidance. PLoS One 2020; 15:e0229441. [PMID: 32214326 PMCID: PMC7098612 DOI: 10.1371/journal.pone.0229441] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2019] [Accepted: 02/06/2020] [Indexed: 12/30/2022] Open
Abstract
PURPOSE In this paper we compared two different 3D ultrasound (US) modes (3D free-hand mode and 3D wobbler mode) to see which is more suitable to perform the 3D-US/3D-US registration for clinical guidance applications. The typical errors with respect to their impact on the final localization error were evaluated step by step. METHODS Multi-point target and Hand-eye calibration methods were used for 3D US calibration together with a newly designed multi-cone phantom. Pointer based and image based methods were used for 2D US calibration. The calibration target error was computed by using a different multi-cone phantom. An egg-shaped phantom was used as ground truth to compare distortions for both 3D modes along with the measurements of the volume. Finally, we compared 3D ultrasound images acquired by 3D wobbler mode and 3D free-hand mode with respect to their 3D-US/3D-US registration accuracy using both, phantom and patient data. A theoretical step by step error analysis was performed and compared to empirical data. RESULTS Target registration errors based on the calibration with the 3D Multi-point and 2D pointer/image method have been found to be comparable (∼1mm). They both outperformed the 3D Hand-eye method (error >2mm). Volume measurements with the 3D free-hand mode were closest to the ground truth (around 6% error compared to 9% with the 3D wobbler mode). Additional scans on phantoms showed a 3D-US/3D-US registration error below 1 mm for both, the 3D free-hand mode and the 3D wobbler mode, respectively. Results with patient data showed greater error with the 3D free-hand mode (6.50mm - 13.37mm) than with the 3D wobbler mode (2.99 ± 1.54 mm). All the measured errors were found to be in accordance to their theoretical upper bounds. CONCLUSION While both 3D volume methods showed comparable results with respect to 3D-US/3D-US registration for phantom images, for patient data registrations the 3D wobbler mode is superior to the 3D free-hand mode. The effect of all error sources could be estimated by theoretical derivations.
Collapse
Affiliation(s)
- David Iommi
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Johann Hummel
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
- * E-mail:
| | - Michael Lutz Figl
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
2
|
Ipsen S, Bruder R, Kuhlemann I, Jauer P, Motisi L, Cremers F, Ernst F, Schweikard A. A visual probe positioning tool for 4D ultrasound-guided radiotherapy. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2018; 2018:883-886. [PMID: 30440532 DOI: 10.1109/embc.2018.8512390] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Ultrasound (US) guidance is a rapidly growing area in image-guided radiotherapy. For motion compensation, the therapy target needs to be visualized with the US probe to continuously determine its position and adapt for shifts. While US has obvious benefits such as real-time capability and proven safety, one of the main drawbacks to date is its user dependency - high quality results require long years of clinical experience. To provide positioning assistance for the setup of US equipment by non-experts, we developed a visual guidance tool combining real-time US volume and CT visualization in a geometrically calibrated setup. By using a 4D US station with real-time data access and an optical tracking system, we achieved a calibration accuracy of 1.2 mm and a mean 2D contour distance of 1.7 mm between organ boundaries identified in US and CT. With this low calibration error as well as the good visual alignment of the structures, the developed probe positioning tool could be a valuable aid for ultrasound-guided radiotherapy and other interventions by guiding the user to a suitable acoustic window while potentially improving setup reproducibility.
Collapse
|
3
|
Early prediction of tumor response to bevacizumab treatment in murine colon cancer models using three-dimensional dynamic contrast-enhanced ultrasound imaging. Angiogenesis 2017; 20:547-555. [PMID: 28721500 DOI: 10.1007/s10456-017-9566-5] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2017] [Accepted: 07/13/2017] [Indexed: 12/18/2022]
Abstract
Due to spatial tumor heterogeneity and consecutive sampling errors, it is critically important to assess treatment response following antiangiogenic therapy in three dimensions as two-dimensional assessment has been shown to substantially over- and underestimate treatment response. In this study, we evaluated whether three-dimensional (3D) dynamic contrast-enhanced ultrasound (DCE-US) imaging allows assessing early changes in tumor perfusion following antiangiogenic treatment (bevacizumab administered at a dose of 10 mg/kg b.w.), and whether these changes could predict treatment response in colon cancer tumors that either are responsive (LS174T tumors) or none responsive (CT26) to the proposed treatment. Our results showed that the perfusion parameters of 3D DCE-US including peak enhancement (PE) and area under curve (AUC) significantly decreased by up to 69 and 77%, respectively, in LS174T tumors within 1 day after antiangiogenic treatment (P = 0.005), but not in CT26 tumors (P > 0.05). Similarly, the percentage area of neovasculature significantly decreased in treated versus control LS174T tumors (P < 0.001), but not in treated versus control CT26 tumors (P = 0.796). Early decrease in both PE and AUC by 45-50% was predictive of treatment response in 100% (95% CI 69.2, 100%) of responding tumors, and in 100% (95% CI 88.4, 100%) and 86.7% (95% CI 69.3, 96.2%), respectively, of nonresponding tumors. In conclusion, 3D DCE-US provides clinically relevant information on the variability of tumor response to antiangiogenic therapy and may be further developed as biomarker for predicting treatment outcomes.
Collapse
|
4
|
Schlosser J, Gong RH, Bruder R, Schweikard A, Jang S, Henrie J, Kamaya A, Koong A, Chang DT, Hristov D. Robotic intrafractional US guidance for liver SABR: System design, beam avoidance, and clinical imaging. Med Phys 2017; 43:5951. [PMID: 27806580 DOI: 10.1118/1.4964454] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To present a system for robotic 4D ultrasound (US) imaging concurrent with radiotherapy beam delivery and estimate the proportion of liver stereotactic ablative body radiotherapy (SABR) cases in which robotic US image guidance can be deployed without interfering with clinically used VMAT beam configurations. METHODS The image guidance hardware comprises a 4D US machine, an optical tracking system for measuring US probe pose, and a custom-designed robot for acquiring hands-free US volumes. In software, a simulation environment incorporating the LINAC, couch, planning CT, and robotic US guidance hardware was developed. Placement of the robotic US hardware was guided by a target visibility map rendered on the CT surface by using the planning CT to simulate US propagation. The visibility map was validated in a prostate phantom and evaluated in patients by capturing live US from imaging positions suggested by the visibility map. In 20 liver SABR patients treated with VMAT, the simulation environment was used to virtually place the robotic hardware and US probe. Imaging targets were either planning target volumes (PTVs, range 5.9-679.5 ml) or gross tumor volumes (GTVs, range 0.9-343.4 ml). Presence or absence of mechanical interference with LINAC, couch, and patient body as well as interferences with treated beams was recorded. RESULTS For PTV targets, robotic US guidance without mechanical interference was possible in 80% of the cases and guidance without beam interference was possible in 60% of the cases. For the smaller GTV targets, these proportions were 95% and 85%, respectively. GTV size (1/20), elongated shape (1/20), and depth (1/20) were the main factors limiting the availability of noninterfering imaging positions. The robotic US imaging system was deployed in two liver SABR patients during CT simulation with successful acquisition of 4D US sequences in different imaging positions. CONCLUSIONS This study indicates that for VMAT liver SABR, robotic US imaging of a relevant internal target may be possible in 85% of the cases while using treatment plans currently deployed in the clinic. With beam replanning to account for the presence of robotic US guidance, intrafractional US may be an option for 95% of the liver SABR cases.
Collapse
Affiliation(s)
| | - Ren Hui Gong
- Department of Radiation Oncology, School of Medicine, Stanford University, Stanford, California 94305
| | - Ralf Bruder
- Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23538, Germany
| | - Achim Schweikard
- Institute for Robotics and Cognitive Systems, University of Luebeck, Luebeck 23538, Germany
| | - Sungjune Jang
- Biorobotics Lab, Department of Mechanical Engineering, Stanford University, Stanford, California 94305
| | - John Henrie
- Biorobotics Lab, Department of Mechanical Engineering, Stanford University, Stanford, California 94305
| | - Aya Kamaya
- Department of Radiology, School of Medicine, Stanford University, Stanford, California 94305
| | - Albert Koong
- Department of Radiation Oncology, School of Medicine, Stanford University, Stanford, California 94305
| | - Daniel T Chang
- Department of Radiation Oncology, School of Medicine, Stanford University, Stanford, California 94305
| | - Dimitre Hristov
- Department of Radiation Oncology, School of Medicine, Stanford University, Stanford, California 94305
| |
Collapse
|
5
|
Wang H, Lutz AM, Hristov D, Tian L, Willmann JK. Intra-Animal Comparison between Three-dimensional Molecularly Targeted US and Three-dimensional Dynamic Contrast-enhanced US for Early Antiangiogenic Treatment Assessment in Colon Cancer. Radiology 2016; 282:443-452. [PMID: 27490690 DOI: 10.1148/radiol.2016160032] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Purpose To perform an intra-animal comparison between (a) three-dimensional (3D) molecularly targeted ultrasonography (US) by using clinical-grade vascular endothelial growth factor receptor 2 (VEGFR2)-targeted microbubbles and (b) 3D dynamic contrast material-enhanced (DCE) US by using nontargeted microbubbles for assessment of antiangiogenic treatment effects in a murine model of human colon cancer. Materials and Methods Twenty-three mice with human colon cancer xenografts were randomized to receive either single-dose antiangiogenic treatment (bevacizumab, n = 14) or control treatment (saline, n = 9). At baseline and 24 hours after treatment, animals were imaged with a clinical US system equipped with a clinical matrix array transducer by using the following techniques: (a) molecularly targeted US with VEGFR2-targeted microbubbles, (b) bolus DCE US with nontargeted microbubbles, and (c) destruction-replenishment DCE US with nontargeted microbubbles. VEGFR2-targeted US signal, peak enhancement, area under the time-intensity curve, time to peak, relative blood volume (rBV), relative blood flow, and blood flow velocity were quantified. VEGFR2 expression and percentage area of blood vessels were assessed ex vivo with quantitative immunofluorescence and correlated with corresponding in vivo US parameters. Statistical analysis was performed with Wilcoxon signed rank tests and rank sum tests, as well as Pearson correlation analysis. Results Molecularly targeted US signal with VEGFR2-targeted microbubbles, peak enhancement, and rBV significantly decreased (P ≤ .03) after a single antiangiogenic treatment compared with those in the control group; similarly, ex vivo VEGFR2 expression (P = .03) and percentage area of blood vessels (P = .03) significantly decreased after antiangiogenic treatment. Three-dimensional molecularly targeted US signal correlated well with VEGFR2 expression (r = 0.86, P = .001), and rBV (r = 0.71, P = .01) and relative blood flow (r = 0.78, P = .005) correlated well with percentage area of blood vessels, while other US perfusion parameters did not. Conclusion Three-dimensional molecularly targeted US and destruction-replenishment 3D DCE US provide complementary molecular and functional in vivo imaging information on antiangiogenic treatment effects in human colon cancer xenografts compared with ex vivo reference standards. © RSNA, 2016 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Huaijun Wang
- From the Department of Radiology and Molecular Imaging Program at Stanford (H.W., A.M.L., J.K.W.), Department of Radiation Oncology (D.H.), and Department of Health, Research & Policy (L.T.), School of Medicine, Stanford University, 300 Pasteur Dr, Room H1307, Stanford, CA 94305-5621
| | - Amelie M Lutz
- From the Department of Radiology and Molecular Imaging Program at Stanford (H.W., A.M.L., J.K.W.), Department of Radiation Oncology (D.H.), and Department of Health, Research & Policy (L.T.), School of Medicine, Stanford University, 300 Pasteur Dr, Room H1307, Stanford, CA 94305-5621
| | - Dimitre Hristov
- From the Department of Radiology and Molecular Imaging Program at Stanford (H.W., A.M.L., J.K.W.), Department of Radiation Oncology (D.H.), and Department of Health, Research & Policy (L.T.), School of Medicine, Stanford University, 300 Pasteur Dr, Room H1307, Stanford, CA 94305-5621
| | - Lu Tian
- From the Department of Radiology and Molecular Imaging Program at Stanford (H.W., A.M.L., J.K.W.), Department of Radiation Oncology (D.H.), and Department of Health, Research & Policy (L.T.), School of Medicine, Stanford University, 300 Pasteur Dr, Room H1307, Stanford, CA 94305-5621
| | - Jürgen K Willmann
- From the Department of Radiology and Molecular Imaging Program at Stanford (H.W., A.M.L., J.K.W.), Department of Radiation Oncology (D.H.), and Department of Health, Research & Policy (L.T.), School of Medicine, Stanford University, 300 Pasteur Dr, Room H1307, Stanford, CA 94305-5621
| |
Collapse
|
6
|
Zhou J, Wang H, Zhang H, Lutz AM, Tian L, Hristov D, Willmann JK. VEGFR2-Targeted Three-Dimensional Ultrasound Imaging Can Predict Responses to Antiangiogenic Therapy in Preclinical Models of Colon Cancer. Cancer Res 2016; 76:4081-9. [PMID: 27206846 DOI: 10.1158/0008-5472.can-15-3271] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2015] [Accepted: 04/25/2016] [Indexed: 12/12/2022]
Abstract
Three-dimensional (3D) imaging capabilities to assess responses to anticancer therapies are needed to minimize sampling errors common to two-dimensional approaches as a result of spatial heterogeneity in tumors. Recently, the feasibility and reproducibility of 3D ultrasound molecular imaging (3D USMI) using contrast agents, which target molecular markers, have greatly improved, due to the development of clinical 3D matrix array transducers. Here we report preclinical proof-of-concept studies showing that 3D USMI of VEGFR2/KDR expression accurately gauges longitudinal treatment responses to antiangiogenesis therapy in responding versus nonresponding mouse models of colon cancer. Tumors in these models exhibited differential patterns of VEGFR2-targeted 3D USMI signals during the course of antiangiogenic treatment with bevacizumab. In responding tumors, the VEGFR2 signal decreased as soon as 24 hours after therapy was started, whereas in nonresponding tumors there was no change in signal at any time point. The early decrease in VEGFR2 signal was highly predictive of treatment outcome at the end of therapy. Our results offer preclinical proof that 3D USMI can predict responses to antiangiogenic therapy, warranting further investigation of its clinical translatability to predicting treatment outcomes in patients. Cancer Res; 76(14); 4081-9. ©2016 AACR.
Collapse
Affiliation(s)
- Jianhua Zhou
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University, School of Medicine, Stanford, California. Department of Ultrasound, Sun Yat-Sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, China
| | - Huaijun Wang
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University, School of Medicine, Stanford, California
| | - Huiping Zhang
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University, School of Medicine, Stanford, California
| | - Amelie M Lutz
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University, School of Medicine, Stanford, California
| | - Lu Tian
- Department of Health, Research & Policy, Stanford University, Stanford, California
| | - Dimitre Hristov
- Department of Radiation Oncology, Stanford University, Stanford, California
| | - Jürgen K Willmann
- Department of Radiology, Molecular Imaging Program at Stanford, Stanford University, School of Medicine, Stanford, California.
| |
Collapse
|
7
|
Sarrazin J, Promayon E, Baumann M, Troccaz J. Hand-eye calibration of a robot--UltraSound probe system without any 3D localizers. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:21-4. [PMID: 26736191 DOI: 10.1109/embc.2015.7318251] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
3D UltraSound (US) probes are used in clinical applications for their ease of use and ability to obtain intra-operative volumes. In surgical navigation applications a calibration step is needed to localize the probe in a general coordinate system. This paper presents a new hand-eye calibration method using directly the kinematic model of a robot and US volume registration data that does not require any 3D localizers. First results show a targeting error of 2.34 mm on an experimental setup using manual segmentation of five beads in ten US volumes.
Collapse
|
8
|
Three-dimensional ultrasound molecular imaging of angiogenesis in colon cancer using a clinical matrix array ultrasound transducer. Invest Radiol 2015; 50:322-9. [PMID: 25575176 DOI: 10.1097/rli.0000000000000128] [Citation(s) in RCA: 38] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
OBJECTIVES We sought to assess the feasibility and reproducibility of 3-dimensional ultrasound molecular imaging (USMI) of vascular endothelial growth factor receptor 2 (VEGFR2) expression in tumor angiogenesis using a clinical matrix array transducer and a clinical grade VEGFR2-targeted contrast agent in a murine model of human colon cancer. MATERIALS AND METHODS Animal studies were approved by the Institutional Administrative Panel on Laboratory Animal Care. Mice with human colon cancer xenografts (n = 33) were imaged with a clinical ultrasound system and transducer (Philips iU22; X6-1) after intravenous injection of either clinical grade VEGFR2-targeted microbubbles or nontargeted control microbubbles. Nineteen mice were scanned twice to assess imaging reproducibility. Fourteen mice were scanned both before and 24 hours after treatment with either bevacizumab (n = 7) or saline only (n = 7). Three-dimensional USMI data sets were retrospectively reconstructed into multiple consecutive 1-mm-thick USMI data sets to simulate 2-dimensional imaging. Vascular VEGFR2 expression was assessed ex vivo using immunofluorescence. RESULTS Three-dimensional USMI was highly reproducible using both VEGFR2-targeted microbubbles and nontargeted control microbubbles (intraclass correlation coefficient, 0.83). The VEGFR2-targeted USMI signal significantly (P = 0.02) decreased by 57% after antiangiogenic treatment compared with the control group, which correlated well with ex vivo VEGFR2 expression on immunofluorescence (ρ = 0.93, P = 0.003). If only central 1-mm tumor planes were analyzed to assess antiangiogenic treatment response, the USMI signal change was significantly (P = 0.006) overestimated by an average of 27% (range, 2%-73%) compared with 3-dimensional USMI. CONCLUSIONS Three-dimensional USMI is feasible and highly reproducible and allows accurate assessment and monitoring of VEGFR2 expression in tumor angiogenesis in a murine model of human colon cancer.
Collapse
|
9
|
Fontanarosa D, van der Meer S, Bamber J, Harris E, O'Shea T, Verhaegen F. Review of ultrasound image guidance in external beam radiotherapy: I. Treatment planning and inter-fraction motion management. Phys Med Biol 2015; 60:R77-114. [PMID: 25592664 DOI: 10.1088/0031-9155/60/3/r77] [Citation(s) in RCA: 72] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
In modern radiotherapy, verification of the treatment to ensure the target receives the prescribed dose and normal tissues are optimally spared has become essential. Several forms of image guidance are available for this purpose. The most commonly used forms of image guidance are based on kilovolt or megavolt x-ray imaging. Image guidance can also be performed with non-harmful ultrasound (US) waves. This increasingly used technique has the potential to offer both anatomical and functional information.This review presents an overview of the historical and current use of two-dimensional and three-dimensional US imaging for treatment verification in radiotherapy. The US technology and the implementation in the radiotherapy workflow are described. The use of US guidance in the treatment planning process is discussed. The role of US technology in inter-fraction motion monitoring and management is explained, and clinical studies of applications in areas such as the pelvis, abdomen and breast are reviewed. A companion review paper (O'Shea et al 2015 Phys. Med. Biol. submitted) will extensively discuss the use of US imaging for intra-fraction motion quantification and novel applications of US technology to RT.
Collapse
Affiliation(s)
- Davide Fontanarosa
- Department of Radiation Oncology (MAASTRO), GROW School for Oncology and Developmental Biology, Maastricht University Medical Center (MUMC), Maastricht 6201 BN, the Netherlands. Oncology Solutions Department, Philips Research, High Tech Campus 34, Eindhoven 5656 AE, the Netherlands
| | | | | | | | | | | |
Collapse
|