1
|
Sanders JL, Biliroglu AO, Newsome IG, Adelegan OJ, Yamaner FY, Dayton PA, Oralkan O. A Handheld Imaging Probe for Acoustic Angiography With an Ultrawideband Capacitive Micromachined Ultrasonic Transducer (CMUT) Array. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:2318-2330. [PMID: 35522635 PMCID: PMC9716577 DOI: 10.1109/tuffc.2022.3172566] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This article presents an imaging probe with a 256-element ultrawideband (UWB) 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for acoustic angiography (AA). This array was fabricated on a borosilicate glass wafer with a reduced bottom electrode and an additional central plate mass to achieve the broad bandwidth. A custom 256-channel handheld probe was designed and implemented with integrated low-noise amplifiers and supporting power circuitry. This probe was used to characterize the UWB CMUT, which has a functional 3-dB frequency band from 3.5 to 23.5 MHz. A mechanical index (MI) of 0.33 was achieved at 3.5 MHz at a depth of 11 mm. These promising measurements are then combined to demonstrate AA. The use of alternate amplitude modulation (aAM) combined with a frequency analysis of the measured transmit signal demonstrates the suitability of the UWB CMUT for AA. This is achieved by measuring only a low level of unwanted high-frequency harmonics in both the transmit signal and the reconstructed image in the areas other than the contrast bubbles.
Collapse
|
2
|
Zhou M, Ouzounov S, Cantatore E, Harpe P. An RX AFE With Programmable BP Filter and Digitization for Ultrasound Harmonic Imaging. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2021; 15:1430-1440. [PMID: 34910638 DOI: 10.1109/tbcas.2021.3135859] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This paper presents a front-end integrated circuit for ultrasound (US) harmonic imaging, interfacing to a one-dimensional capacitive micromachined ultrasonic transducer (CMUT). It contains a complete ultrasound receiving chain, from analog front-end (AFE) to gigabit/s data link. A two-stage self-biased inverter-based transimpedance amplifier (TIA) is proposed in this work to improve tradeoffs between power, noise, and linearity at the first stage. To improve harmonic imaging performance, the design is further equipped with a 4[Formula: see text]-order highly programmable bandpass filter, which has a tunable bandwidth from 2 MHz to 15 MHz. An 8 b 80 MS/s SAR ADC digitizes the signal, which is further encoded and serialized into an LVDS data link, enabling a reduction in the number of output cables for future systems with multiple ADCs. The design is realized in a 40 nm CMOS technology. Electrical measurements show it consumes 2.9 mW for the AFE and 2.1 mW for the ADC and digital blocks. Its overall dynamic range varies from 61 dB to 69 dB, depending on the reception bandwidth. The imaging capability of this design is further demonstrated in a US transmission and reception imaging system. The acoustic measurements prove successful ultrasound harmonic acquisition, where the on-chip bandpass filter can improve the lateral resolution by more than 30%.
Collapse
|
3
|
Dauba A, Goulas J, Colin L, Jourdain L, Larrat B, Gennisson JL, Certon D, Novell A. Evaluation of capacitive micromachined ultrasonic transducers for passive monitoring of microbubble-assisted ultrasound therapies. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2020; 148:2248. [PMID: 33138521 DOI: 10.1121/10.0002096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Accepted: 09/11/2020] [Indexed: 06/11/2023]
Abstract
Passive cavitation detection can be performed to monitor microbubble activity during brain therapy. Microbubbles under ultrasound exposure generate a response characterized by multiple nonlinear emissions. Here, the wide bandwidth of capacitive micromachined ultrasonic transducers (CMUTs) was exploited to monitor the microbubble signature through a rat skull and a macaque skull. The intrinsic nonlinearity of the CMUTs was characterized in receive mode. Indeed, undesirable nonlinear components generated by the CMUTs must be minimized as they can mask the microbubble harmonic response. The microbubble signature at harmonic and ultra-harmonic components (0.5-6 MHz) was successfully extracted through a rat skull using moderate bias voltage.
Collapse
Affiliation(s)
- Ambre Dauba
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Service Hospitalier Frédéric Joliot, Orsay, 91401, France
| | - Jordane Goulas
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Service Hospitalier Frédéric Joliot, Orsay, 91401, France
| | - Laurent Colin
- GREMAN CNRS UMR 7347, Université François Rabelais, INSA Centre Val de Loire, Tours, France
| | - Laurène Jourdain
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Service Hospitalier Frédéric Joliot, Orsay, 91401, France
| | - Benoit Larrat
- Université Paris-Saclay, CEA, CNRS, Baobab, NeuroSpin, Gif-sur-Yvette, 91191, France
| | - Jean-Luc Gennisson
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Service Hospitalier Frédéric Joliot, Orsay, 91401, France
| | - Dominique Certon
- GREMAN CNRS UMR 7347, Université François Rabelais, INSA Centre Val de Loire, Tours, France
| | - Anthony Novell
- Université Paris-Saclay, CEA, CNRS, Inserm, BioMaps, Service Hospitalier Frédéric Joliot, Orsay, 91401, France
| |
Collapse
|
4
|
Lindsey BD, Kim J, Dayton PA, Jiang X. Dual-Frequency Piezoelectric Endoscopic Transducer for Imaging Vascular Invasion in Pancreatic Cancer. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:1078-1086. [PMID: 28489536 PMCID: PMC5568756 DOI: 10.1109/tuffc.2017.2702010] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
Cancers of the pancreas have the poorest prognosis among all cancers, as many tumors are not detected until surgery is no longer a viable option. Surgical viability is typically determined via endoscopic ultrasound imaging. However, many patients who may be eligible for resection are not offered surgery due to diagnostic challenges in determining vascular or lymphatic invasion. In this paper, we describe the development of a dual-frequency piezoelectric transducer for rotational endoscopic imaging designed to transmit at 4 MHz and receive at 20 MHz in order to image microbubble-specific superharmonic signals. Imaging performance is assessed in a tissue-mimicking phantom at depths from 1 cm [contrast-to-tissue ratio (CTR) = 21.6 dB] to 2.5 cm (CTR = 11.4 dB), in ex vivo porcine vessels, and in vivo in a rodent. The prototyped 1.1-mm aperture transducer demonstrates contrast-specific imaging of microbubbles in a 200- [Formula: see text]-diameter tube through the wall of a 1-cm-diameter porcine artery, suggesting such a device may enable direct visualization of small vessels from within the lumen of larger vessels such as the portal vein or superior mesenteric vein.
Collapse
|
5
|
Fouan D, Bouakaz A. Investigation of Classical Pulse Sequences for Contrast-Enhanced Ultrasound Imaging With a cMUT Probe. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1496-1504. [PMID: 27187953 DOI: 10.1109/tuffc.2016.2567641] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Capacitive micromachined ultrasonic transducers (cMUTs) provide promising ultrasonic technology that could become an alternative to piezoelectric probes for medical applications. cMUTs could be very valuable for contrast-enhanced ultrasound imaging based on higher harmonics detection. However, their use is restricted by the intrinsic nonlinearity of the cMUT transmitters themselves, because it is difficult to distinguish between the nonlinearity of the microbubbles and the nonlinearity arising from the emitting transducer. A number of approaches have been proposed in recent years to cancel the nonlinearity of cMUTs. However, these techniques have limitations in terms of implementation with current ultrasound scanner electronics. The solution to be comparable with classical methods should not need precharacterization of the probe or changing the bias voltage (amplitude or polarity) but does need good sensitivity and a high frame rate to avoid motion artifacts. We propose here proof of a concept of an adapted amplitude modulation sequence with cMUT where transmit elements operate alternately. We show that this method, which is currently used with piezoelectric probes, is fully applicable to cMUT probes and the intrinsic nonlinearity of the transmitter is no longer an issue.
Collapse
|
6
|
Satir S, Degertekin FL. Phase and Amplitude Modulation Methods for Nonlinear Ultrasound Imaging With CMUTs. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2016; 63:1086-1092. [PMID: 27116737 PMCID: PMC4988869 DOI: 10.1109/tuffc.2016.2557621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
Conventional amplitude and phase modulated pulse sequences for selective imaging of nonlinear tissue and ultrasound contrast agents are designed for piezoelectric transducers that behave linearly. Inherent nonlinearity of capacitive micromachined ultrasonic transducers (CMUTs), especially during large-signal operation, renders these methods inapplicable. In this paper, we present different pulse sequences for nonlinear imaging that are valid for small- and large-signal CMUT operations. For small-signal operation, two-pulse amplitude and phase modulation methods for microbubble and tissue harmonic imaging are presented, where CMUT nonlinearity is compensated via subharmonic excitation. In the large-signal regime, using a nonlinear model, we first show that there is a simple linear relationship between the phases of each harmonic distortion component generated and the input drive signal. Based on this observation, we demonstrate a pulse sequence using N+1 consecutive phase modulated transmit events to extract N harmonics of the nonlinear contrast agent echo content uncorrupted by CMUT nonlinearity. The proposed methods assume no apriori information about the transducer and, therefore, are applicable to any CMUT. The phase modulation method is also valid for piezoelectric transducers and systems with nonlinearities described by Taylor series where the same phase relationship between the input signal and the harmonic content is valid. The proof of principle experiments using a commercial contrast agent validates the phase modulated pulse sequences for CMUTs, operating in a highly nonlinear collapse-snapback mode and for piezoelectric transducers.
Collapse
Affiliation(s)
- Sarp Satir
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology
| | - F. Levent Degertekin
- G.W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology
- School of Electrical and Computer Engineering, Georgia Institute of Technology
| |
Collapse
|
7
|
Novell A, Arena CB, Oralkan O, Dayton PA. Wideband acoustic activation and detection of droplet vaporization events using a capacitive micromachined ultrasonic transducer. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2016; 139:3193. [PMID: 27369143 PMCID: PMC5848826 DOI: 10.1121/1.4953580] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/14/2015] [Revised: 03/02/2016] [Accepted: 04/04/2016] [Indexed: 05/05/2023]
Abstract
An ongoing challenge exists in understanding and optimizing the acoustic droplet vaporization (ADV) process to enhance contrast agent effectiveness for biomedical applications. Acoustic signatures from vaporization events can be identified and differentiated from microbubble or tissue signals based on their frequency content. The present study exploited the wide bandwidth of a 128-element capacitive micromachined ultrasonic transducer (CMUT) array for activation (8 MHz) and real-time imaging (1 MHz) of ADV events from droplets circulating in a tube. Compared to a commercial piezoelectric probe, the CMUT array provides a substantial increase of the contrast-to-noise ratio.
Collapse
Affiliation(s)
- Anthony Novell
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599, USA
| | - Christopher B Arena
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599, USA
| | - Omer Oralkan
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599, USA
| | - Paul A Dayton
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, North Carolina 27599, USA
| |
Collapse
|
8
|
Novell A, Arena CB, Kasoji S, Dayton PA. Optimization of multi-pulse sequences for nonlinear contrast agent imaging using a cMUT array. Phys Med Biol 2015; 60:3111-27. [PMID: 25803232 DOI: 10.1088/0031-9155/60/8/3111] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Capacitive micromachined ultrasonic transducer (cMUT) technology provides advantages such as wide frequency bandwidth, which can be exploited for contrast agent imaging. Nevertheless, the efficiency of traditional multi-pulse imaging schemes, such as pulse inversion (PI), remains limited because of the intrinsic nonlinear character of cMUTs. Recently, a new contrast imaging sequence, called bias voltage modulation sequence (BVM), has been specifically developed for cMUTs to suppress their unwanted nonlinear behavior. In this study, we propose to optimize contrast agent detection by combining the BVM sequence with PI and/or chirp reversal (CR). An aqueous dispersion of lipid encapsulated microbubbles was exposed to several combinations of multi-pulse imaging sequences. Approaches were evaluated in vitro using 9 inter-connected elements of a cMUT linear array (excitation frequency of 4 MHz; peak negative pressure of 100 kPa). For sequences using chirp excitations, a specific compression filter was designed to compress and extract several nonlinear components from the received microbubble responses. A satisfactory cancellation of the nonlinear signal from the source is achieved when BVM is combined with PI and CR. In comparison with PI and CR imaging modes alone, using sequences incorporating BVM increases the contrast-to-tissue ratio by 10.0 dB and 4.6 dB, respectively. Furthermore, the combination of BVM with CR and PI results in a significant increase of the contrast-to-noise ratio (+29 dB). This enhancement is attributed to the use of chirps as excitation signals and the improved preservation of several nonlinear components contained within the contrast agent response.
Collapse
Affiliation(s)
- Anthony Novell
- Joint Department of Biomedical Engineering, The University of North Carolina and North Carolina State University, Chapel Hill, NC 27599, USA
| | | | | | | |
Collapse
|
9
|
Dual-frequency piezoelectric transducers for contrast enhanced ultrasound imaging. SENSORS 2014; 14:20825-42. [PMID: 25375755 PMCID: PMC4279513 DOI: 10.3390/s141120825] [Citation(s) in RCA: 43] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/06/2014] [Revised: 10/03/2014] [Accepted: 10/16/2014] [Indexed: 01/10/2023]
Abstract
For many years, ultrasound has provided clinicians with an affordable and effective imaging tool for applications ranging from cardiology to obstetrics. Development of microbubble contrast agents over the past several decades has enabled ultrasound to distinguish between blood flow and surrounding tissue. Current clinical practices using microbubble contrast agents rely heavily on user training to evaluate degree of localized perfusion. Advances in separating the signals produced from contrast agents versus surrounding tissue backscatter provide unique opportunities for specialized sensors designed to image microbubbles with higher signal to noise and resolution than previously possible. In this review article, we describe the background principles and recent developments of ultrasound transducer technology for receiving signals produced by contrast agents while rejecting signals arising from soft tissue. This approach relies on transmitting at a low-frequency and receiving microbubble harmonic signals at frequencies many times higher than the transmitted frequency. Design and fabrication of dual-frequency transducers and the extension of recent developments in transducer technology for dual-frequency harmonic imaging are discussed.
Collapse
|