Kertész H, Beyer T, Panin V, Jentzen W, Cal-Gonzalez J, Berger A, Papp L, Kench PL, Bharkhada D, Cabello J, Conti M, Rausch I. Implementation of a Spatially-Variant and Tissue-Dependent Positron Range Correction for PET/CT Imaging. Front Physiol 2022; 13:818463. [PMID: 35350691 PMCID: PMC8957980 DOI: 10.3389/fphys.2022.818463] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Accepted: 02/10/2022] [Indexed: 11/13/2022] Open
Abstract
Aim To develop and evaluate a new approach for spatially variant and tissue-dependent positron range (PR) correction (PRC) during the iterative PET image reconstruction. Materials and Methods The PR distributions of three radionuclides (18F, 68Ga, and 124I) were simulated using the GATE (GEANT4) framework in different material compositions (lung, water, and bone). For every radionuclide, the uniform PR kernel was created by mapping the simulated 3D PR point cloud to a 3D matrix with its size defined by the maximum PR in lung (18F) or water (68Ga and 124I) and the PET voxel size. The spatially variant kernels were composed from the uniform PR kernels by analyzing the material composition of the surrounding medium for each voxel before implementation as tissue-dependent, point-spread functions into the iterative image reconstruction. The proposed PRC method was evaluated using the NEMA image quality phantom (18F, 68Ga, and 124I); two unique PR phantoms were scanned and evaluated following OSEM reconstruction with and without PRC using different metrics, such as contrast recovery, contrast-to-noise ratio, image noise and the resolution evaluated in terms of full width at half maximum (FWHM). Results The effect of PRC on 18F-imaging was negligible. In contrast, PRC improved image contrast for the 10-mm sphere of the NEMA image quality phantom filled with 68Ga and 124I by 33 and 24%, respectively. While the effect of PRC was less noticeable for the larger spheres, contrast recovery still improved by 5%. The spatial resolution was improved by 26% for 124I (FWHM of 4.9 vs. 3.7 mm). Conclusion For high energy positron-emitting radionuclides, the proposed PRC method helped recover image contrast with reduced noise levels and with improved spatial resolution. As such, the PRC approach proposed here can help improve the quality of PET data in clinical practice and research.
Collapse
Affiliation(s)
- Hunor Kertész
- QIMP Team, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Thomas Beyer
- QIMP Team, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Vladimir Panin
- Siemens Medical Solutions USA, Inc., Knoxville, TN, United States
| | - Walter Jentzen
- Clinic for Nuclear Medicine, University Hospital Essen, Essen, Germany
| | - Jacobo Cal-Gonzalez
- QIMP Team, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria.,Ion Beam Applications, Quirónsalud Proton Therapy Center, Madrid, Spain
| | - Alexander Berger
- QIMP Team, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Laszlo Papp
- QIMP Team, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Peter L Kench
- Discipline of Medical Imaging Science and Brain and Mind Centre, Faculty of Medicine and Health, The University of Sydney, Sydney, NSW, Australia
| | - Deepak Bharkhada
- Siemens Medical Solutions USA, Inc., Knoxville, TN, United States
| | - Jorge Cabello
- Siemens Medical Solutions USA, Inc., Knoxville, TN, United States
| | - Maurizio Conti
- Siemens Medical Solutions USA, Inc., Knoxville, TN, United States
| | - Ivo Rausch
- QIMP Team, Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
2
|
Cal-González J, Pérez-Liva M, Herraiz JL, Vaquero JJ, Desco M, Udías JM. Tissue-Dependent and Spatially-Variant Positron Range Correction in 3D PET. IEEE TRANSACTIONS ON MEDICAL IMAGING 2015; 34:2394-403. [PMID: 26011878 DOI: 10.1109/tmi.2015.2436711] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
Positron range (PR) is a significant factor that limits PET image resolution, especially with some radionuclides currently used in clinical and preclinical studies such as (82)Rb, (124)I and (68)Ga. The use of an accurate model of the PR in the image reconstruction may minimize its impact on the image quality. Nevertheless, PR distributions are difficult to model, as they may be different at each voxel and direction, depending on the materials that the positron flies through. Several approximated methods have been proposed, considering only one or several propagating media without taking into account boundaries effects. In some regions, like lungs or trachea, these methods may not be accurate enough and yield artifacts. In this work, we present an efficient method to accurately incorporate spatially-variant PR corrections. The method is based on pre-computing voxel-dependent PR kernels using a CT or a manually segmented image, and a model of the dependence of the PR on each material derived from Monte Carlo simulations. The images are convoluted with these kernels in the forward-projection step of the iterative reconstruction algorithm. This implementation of the algorithm adds a modest overhead to the overall reconstruction time and it obtains artifact-free PR-corrected images, even when the activity is concentrated at tissue boundaries with extreme changes of density. We verified the method with the preclinical Argus PET/CT scanner, but it can be also applied to other scanners and improve the image quality in clinical PET studies using isotopes with large PR.
Collapse
|