Kappadath SC, Lopez BP. Single-Compartment Dose Prescriptions for Ablative 90Y-Radioembolization Segmentectomy. Life (Basel) 2023; 13:1238. [PMID: 37374021 DOI: 10.3390/life13061238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 05/18/2023] [Accepted: 05/22/2023] [Indexed: 06/29/2023] Open
Abstract
BACKGROUND Yttrium-90 (90Y) radioembolization is increasingly being utilized with curative intent. While single-compartment doses with respect to the perfused volume for the complete pathologic necrosis (CPN) of tumors have been reported, the actual doses delivered to the tumor and at-risk margins that leads to CPN have hitherto not been estimated. We present an ablative dosimetry model that calculates the dose distribution for tumors and at-risk margins based on numerical mm-scale dose modeling and the available clinical CPN evidence and report on the necessary dose metrics needed to achieve CPN following 90Y-radioembolization. METHODS Three-dimensional (3D) activity distributions (MBq/voxel) simulating spherical tumors were modeled with a 121 × 121 × 121 mm3 soft tissue volume (1 mm3 voxels). Then, 3D dose distributions (Gy/voxel) were estimated by convolving 3D activity distributions with a 90Y 3D dose kernel (Gy/MBq) sized 61 × 61 × 61 mm3 (1 mm3 voxels). Based on the published data on single-compartment segmental doses for the resected liver samples of HCC tumors showing CPN after radiation segmentectomy, the nominal voxel-based mean tumor dose (DmeanCPN), point dose at tumor rim (DrimCPN), and point dose 2 mm beyond the tumor boundary (D2mmCPN), which are necessary to achieve CPN, were calculated. The single-compartment dose prescriptions to required achieve CPN were then analytically modeled for more general cases of tumors with diameters dt = 2, 3, 4, 5, 6, and 7 cm and with tumor-to-normal-liver uptake ratios T:N = 1:1, 2:1, 3:1, 4:1, and 5:1. RESULTS The nominal case defined to estimate the doses needed for CPN, based on the previously published clinical data, was a single hyperperfused tumor with a diameter of 2.5 cm and T:N = 3:1, treated with a single-compartment segmental dose of 400 Gy. The voxel-level doses necessary to achieve CPN were 1053 Gy for the mean tumor dose, 860 Gy for the point dose at the tumor boundary, and 561 Gy for the point dose at 2 mm beyond the tumor edge. The single-compartment segmental doses necessary to satisfy the criteria for CPN in terms of the mean tumor dose, point dose at the tumor boundary, and the point dose at 2 mm beyond the tumor edge were tabulated for a range of tumor diameters and tumor-to-normal-liver uptake ratios. CONCLUSIONS The analytical functions that describe the relevant dose metrics for CPN and, more importantly, the single-compartment dose prescriptions for the perfused volume needed to achieve CPN are reported for a large range of conditions in terms of tumor diameters (1-7 cm) and T:N uptake ratios (2:1-5:1).
Collapse
Affiliation(s)
- Srinivas Cheenu Kappadath
- Department of Imaging Physics, UT MD Anderson Cancer Center, 1155 Pressler St., Unit 1352, Houston, TX 77030, USA
| | - Benjamin P Lopez
- Department of Imaging Physics, UT MD Anderson Cancer Center, 1155 Pressler St., Unit 1352, Houston, TX 77030, USA
| |
Collapse
|
2
|
Sharma NK, Kappadath SC, Chuong M, Folkert M, Gibbs P, Jabbour SK, Jeyarajah DR, Kennedy A, Liu D, Meyer JE, Mikell J, Patel RS, Yang G, Mourtada F. The American Brachytherapy Society consensus statement for permanent implant brachytherapy using Yttrium-90 microsphere radioembolization for liver tumors. Brachytherapy 2022; 21:569-591. [PMID: 35599080 PMCID: PMC10868645 DOI: 10.1016/j.brachy.2022.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 03/25/2022] [Accepted: 04/14/2022] [Indexed: 11/02/2022]
Abstract
PURPOSE To develop a multidisciplinary consensus for high quality multidisciplinary implementation of brachytherapy using Yttrium-90 (90Y) microspheres transarterial radioembolization (90Y TARE) for primary and metastatic cancers in the liver. METHODS AND MATERIALS Members of the American Brachytherapy Society (ABS) and colleagues with multidisciplinary expertise in liver tumor therapy formulated guidelines for 90Y TARE for unresectable primary liver malignancies and unresectable metastatic cancer to the liver. The consensus is provided on the most recent literature and clinical experience. RESULTS The ABS strongly recommends the use of 90Y microsphere brachytherapy for the definitive/palliative treatment of unresectable liver cancer when recommended by the multidisciplinary team. A quality management program must be implemented at the start of 90Y TARE program development and follow-up data should be tracked for efficacy and toxicity. Patient-specific dosimetry optimized for treatment intent is recommended when conducting 90Y TARE. Implementation in patients on systemic therapy should account for factors that may enhance treatment related toxicity without delaying treatment inappropriately. Further management and salvage therapy options including retreatment with 90Y TARE should be carefully considered. CONCLUSIONS ABS consensus for implementing a safe 90Y TARE program for liver cancer in the multidisciplinary setting is presented. It builds on previous guidelines to include recommendations for appropriate implementation based on current literature and practices in experienced centers. Practitioners and cooperative groups are encouraged to use this document as a guide to formulate their clinical practices and to adopt the most recent dose reporting policies that are critical for a unified outcome analysis of future effectiveness studies.
Collapse
Affiliation(s)
- Navesh K Sharma
- Department of Radiation Oncology, Penn State Hershey School of Medicine, Hershey, PA
| | - S Cheenu Kappadath
- Department of Imaging Physics, UT MD Anderson Cancer Center, Houston, TX
| | - Michael Chuong
- Department of Radiation Oncology, Miami Cancer Institute, Miami, FL
| | - Michael Folkert
- Northwell Health Cancer Institute, Radiation Medicine at the Center for Advanced Medicine, New Hyde Park, NY
| | - Peter Gibbs
- Personalised Oncology Division, Walter and Eliza Hall Institute, Melbourne, Victoria, Australia
| | - Salma K Jabbour
- Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ
| | | | | | - David Liu
- Vancouver General Hospital, Vancouver, British Columbia, Canada
| | | | | | - Rahul S Patel
- Icahn School of Medicine at Mount Sinai, New York, NY
| | - Gary Yang
- Loma Linda University, Loma Linda, CA
| | - Firas Mourtada
- Helen F. Graham Cancer Center & Research Institute, Christiana Care Health System, Newark, DE; Department of Radiation Oncology, Sidney Kimmel Cancer Center at Thomas Jefferson University, Philadelphia, PA.
| |
Collapse
|
3
|
Plachouris D, Mountris KA, Papadimitroulas P, Spyridonidis T, Katsanos K, Apostolopoulos D, Papathanasiou N, Hazle JD, Visvikis D, Kagadis GC. Clinical Evaluation of a Three-Dimensional Internal Dosimetry Technique for Liver Radioembolization with 90Y Microspheres Using Dose Voxel Kernels. Cancer Biother Radiopharm 2021; 36:809-819. [PMID: 33656372 DOI: 10.1089/cbr.2020.4554] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022] Open
Abstract
Background: The purpose of this study was to develop a rapid, reliable, and efficient tool for three-dimensional (3D) dosimetry treatment planning and post-treatment evaluation of liver radioembolization with 90Y microspheres, using tissue-specific dose voxel kernels (DVKs) that can be used in everyday clinical practice. Materials and Methods: Two tissue-specific DVKs for 90Y were calculated through Monte Carlo (MC) simulations. DVKs for the liver and lungs were generated, and the dose distribution was compared with direct MC simulations. A method was developed to produce a 3D dose map by convolving the calculated DVKs with the activity biodistribution derived from clinical single-photon emission computed tomography (SPECT) or positron emission tomography (PET) images. Image registration for the SPECT or PET images with the corresponding computed tomography scans was performed before dosimetry calculation. The authors first compared the DVK convolution dosimetry with a direct full MC simulation on an XCAT anthropomorphic phantom. They then tested it in 25 individual clinical cases of patients who underwent 90Y therapy. All MC simulations were carried out using the GATE MC toolkit. Results: Comparison of the measured absorbed dose using tissue-specific DVKs and direct MC simulation on 25 patients revealed a mean difference of 1.07% ± 1.43% for the liver and 1.03% ± 1.21% for the tumor tissue, respectively. The largest difference between DVK convolution and full MC dosimetry was observed for the lung tissue (10.16% ± 1.20%). The DVK statistical uncertainty was <0.75% for both media. Conclusions: This semiautomatic algorithm is capable of performing rapid, accurate, and efficient 3D dosimetry. The proposed method considers tissue and activity heterogeneity using tissue-specific DVKs. Furthermore, this method provides results in <1 min, making it suitable for everyday clinical practice.
Collapse
Affiliation(s)
- Dimitris Plachouris
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece
| | - Konstantinos A Mountris
- Department of Electrical Engineering, Aragon Institute of Engineering Research, IIS Aragon, University of Zaragoza, Zaragoza, Spain
| | | | - Trifon Spyridonidis
- Department of Nuclear Medicine, School of Medicine, University of Patras, Rion, Greece
| | | | | | | | - John D Hazle
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| | | | - George C Kagadis
- 3DMI Research Group, Department of Medical Physics, School of Medicine, University of Patras, Rion, Greece.,Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, USA
| |
Collapse
|
4
|
Howell RW. Advancements in the use of Auger electrons in science and medicine during the period 2015-2019. Int J Radiat Biol 2020; 99:2-27. [PMID: 33021416 PMCID: PMC8062591 DOI: 10.1080/09553002.2020.1831706] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 09/01/2020] [Accepted: 09/28/2020] [Indexed: 02/06/2023]
Abstract
Auger electrons can be highly radiotoxic when they are used to irradiate specific molecular sites. This has spurred basic science investigations of their radiobiological effects and clinical investigations of their potential for therapy. Focused symposia on the biophysical aspects of Auger processes have been held quadrennially. This 9th International Symposium on Physical, Molecular, Cellular, and Medical Aspects of Auger Processes at Oxford University brought together scientists from many different fields to review past findings, discuss the latest studies, and plot the future work to be done. This review article examines the research in this field that was published during the years 2015-2019 which corresponds to the period since the last meeting in Japan. In addition, this article points to future work yet to be done. There have been a plethora of advancements in our understanding of Auger processes. These advancements range from basic atomic and molecular physics to new ways to implement Auger electron emitters in radiopharmaceutical therapy. The highly localized doses of radiation that are deposited within a 10 nm of the decay site make them precision tools for discovery across the physical, chemical, biological, and medical sciences.
Collapse
Affiliation(s)
- Roger W Howell
- Division of Radiation Research, Department of Radiology, New Jersey Medical School, Rutgers University, Newark, NJ, USA
| |
Collapse
|
5
|
Wang A, Maslowski A, Wareing T, Star-Lack J, Schmidt TG. A fast, linear Boltzmann transport equation solver for computed tomography dose calculation (Acuros CTD). Med Phys 2018; 46:925-933. [PMID: 30471131 DOI: 10.1002/mp.13305] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2018] [Revised: 10/28/2018] [Accepted: 11/15/2018] [Indexed: 02/05/2023] Open
Abstract
PURPOSE To improve dose reporting of CT scans, patient-specific organ doses are highly desired. However, estimating the dose distribution in a fast and accurate manner remains challenging, despite advances in Monte Carlo methods. In this work, we present an alternative method that deterministically solves the linear Boltzmann transport equation (LBTE), which governs the behavior of x-ray photon transport through an object. METHODS Our deterministic solver for CT dose (Acuros CTD) is based on the same approach used to estimate scatter in projection images of a CT scan (Acuros CTS). A deterministic method is used to compute photon fluence within the object, which is then converted to deposited energy by multiplying by known, material-specific conversion factors. To benchmark Acuros CTD, we used the AAPM Task Group 195 test for CT dose, which models an axial, fan beam scan (10 mm thick beam) and calculates energy deposited in each organ of an anthropomorphic phantom. We also validated our own Monte Carlo implementation of Geant4 to use as a reference to compare Acuros against for other common geometries like an axial, cone beam scan (160 mm thick beam) and a helical scan (40 mm thick beam with table motion for a pitch of 1). RESULTS For the fan beam scan, Acuros CTD accurately estimated organ dose, with a maximum error of 2.7% and RMSE of 1.4% when excluding organs with <0.1% of the total energy deposited. The cone beam and helical scans yielded similar levels of accuracy compared to Geant4. Increasing the number of source positions beyond 18 or decreasing the voxel size below 5 × 5 × 5 mm3 provided marginal improvement to the accuracy for the cone beam scan but came at the expense of increased run time. Across the different scan geometries, run time of Acuros CTD ranged from 8 to 23 s. CONCLUSIONS In this digital phantom study, a deterministic LBTE solver was capable of fast and accurate organ dose estimates.
Collapse
Affiliation(s)
- Adam Wang
- Varian Medical Systems, Palo Alto, CA, 94304, USA
| | | | - Todd Wareing
- Varian Medical Systems, Palo Alto, CA, 94304, USA
| | | | - Taly Gilat Schmidt
- Department of Biomedical Engineering, Marquette University, Milwaukee, WI, 53201, USA
| |
Collapse
|
6
|
Balagopal A, Kappadath SC. Characterization of 90 Y-SPECT/CT self-calibration approaches on the quantification of voxel-level absorbed doses following 90 Y-microsphere selective internal radiation therapy. Med Phys 2017; 45:875-883. [PMID: 29172243 DOI: 10.1002/mp.12695] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2017] [Revised: 09/27/2017] [Accepted: 11/19/2017] [Indexed: 11/09/2022] Open
Abstract
PURPOSE 90 Y-microsphere selective internal radiation therapy (90 Y-SIRT or 90 Y-radioembolization) is used in the management of unresectable liver tumors. 90 Y-SIRT presents a unique situation where the total 90 Y activity inside the liver can be determined with high accuracy (> 95%). 90 Y bremsstrahlung single-photon emission computed tomography (SPECT)/computed tomography (CT) can be self-calibrated to provide quantitative images that facilitate voxel-level absorbed dose calculations. We investigated the effects of different approaches for 90 Y-SPECT self-calibration on the quantification of absorbed doses following 90 Y-SIRT. METHODS 90 Y bremsstrahlung SPECT/CT images of 31 patients with hepatocellular carcinoma, collected following 90 Y-SIRT, were analyzed, yielding 48 tumor and 31 normal liver contours. We validated the accuracy of absorbed doses calculated by a commercial software against those calculated using Monte Carlo-based radiation transport. The software package was used to analyze the following definitions of SPECT volume of interest used for 90 Y-SPECT self-calibration: (a) SPECT field-of-view (FOV), (b) chest-abdomen contour, (c) total liver contour, (d) total liver contour expanded by 5 mm, and (e) total liver contour contracted by 5 mm. Linear correlation and Bland-Altman analysis were performed for tumor and normal liver tissue absorbed dose volume histogram metrics between the five different approaches for 90 Y-SPECT self-calibration. RESULTS The mean dose calculated using the commercial software was within 3% of Monte Carlo for tumors and normal liver tissues. The tumor mean dose calculated using the chest-abdomen calibration was within 2% of that calculated using the SPECT FOV, whereas the doses calculated using the total liver contour, expanded total liver contour, and contracted total liver contour were within 68%, 47%, and 107%, respectively, of doses calculated using the SPECT FOV. The normal liver tissue mean dose calculated using the chest-abdomen contour was within 1.3% of that calculated using the SPECT FOV, whereas the doses calculated using the total liver contour, expanded total liver contour, and contracted total liver contour were within 73%, 50%, and 114%, respectively, of doses calculated using the SPECT FOV. CONCLUSIONS The mean error of < 3% for commercial software can be considered clinically acceptable for 90 Y-SIRT dosimetry. Absorbed dose quantification using 90 Y-SPECT self-calibration with the chest-abdomen contour was equivalent to that calculated using the SPECT FOV, but self-calibration with the total liver contour yielded substantially higher (~70%) dose values. The large biases revealed by our study suggest that consistent absorbed dose calculation approaches are essential when comparing 90 Y-SIRT dosimetry between different clinical studies.
Collapse
Affiliation(s)
- Anjali Balagopal
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| | - S Cheenu Kappadath
- Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, 77030, USA
| |
Collapse
|
7
|
Siman W, Mawlawi OR, Mikell JK, Mourtada F, Kappadath SC. Effects of image noise, respiratory motion, and motion compensation on 3D activity quantification in count-limited PET images. Phys Med Biol 2016; 62:448-464. [DOI: 10.1088/1361-6560/aa5088] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|