1
|
Mekis N, Bianchi T, Doyle C, Gauchat M, Geerling I, Linneman J, Staats S, Campeanu C. Gridless adult cervical spine radiography and its' effect on image quality and radiation dose: A phantom study. Radiography (Lond) 2024; 30:359-366. [PMID: 38141429 DOI: 10.1016/j.radi.2023.12.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Revised: 11/27/2023] [Accepted: 12/13/2023] [Indexed: 12/25/2023]
Abstract
INTRODUCTION Imaging of the cervical spine in general radiography is most frequently performed using an anti-scatter grid. The purpose of this study was to investigate the effects of a gridless setting on image quality and radiation dose during digital radiography of the anteroposterior (AP) and lateral (LAT) cervical spine. METHODS A phantom study was performed with a variety of tube voltages (63-75 kV) with and without an anti-scatter grid. The tube current time product (mAs) and dose area product (DAP) were recorded and used to calculate effective dose (ED) and individual organ dose using PCXMC 2.0 software, as well as entrance surface dose (ESD) and objective image quality: signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective visual image quality grading characteristics (VGC) was performed by five qualified radiographers. RESULTS In a gridless setting, the AP and LAT positions showed significantly lower DAP (1.6 μGym2; 61.3 % and 1.6 μGym2; 51.2%), ESD (27.6 μGy; 57.3% and 77.2 μGy; 47.2%) and ED (4.2 μSv; 61.3% and 2.3 μSv; 48.9%). In a gridless setting in the AP position, there is a slight significant deterioration in image quality. In the lateral projection, on the other hand, the image quality without the use of grid was only significantly reduced in three of six criteria and there was no difference in the objective image quality between the two settings examined. CONCLUSION The results of this study show that gridless setting significantly decreases radiation dose and image quality, but the quality in the lateral projection is still acceptable for diagnostic purpose. IMPLICATIONS FOR PRACTICE The protocol without the use of the anti-scatter grid in cervical spine radiography leads to a reduction in the radiation dose in both projections, but the image quality in the AP is significantly reduced for all criteria examined, with a slight deterioration in image quality in the lateral projection.
Collapse
Affiliation(s)
- N Mekis
- University of Ljubljana, Medical Imaging and Radiotherapy Department, Zdravstvena Pot 5, 100 Ljubljana, Slovenia.
| | - T Bianchi
- Department of Technical Medical Radiology, School of Health Sciences (HESAV), University of Applied Sciences and Arts of Western Switzerland (HES-SO), Av. de Beaumont 21, 1011 Lausanne, Switzerland
| | - C Doyle
- Radiography and Diagnostic Imaging, School of Medicine, University College Dublin, Belfied, Dublin 4, D04 V1W8 Ireland
| | - M Gauchat
- Department of Technical Medical Radiology, School of Health Sciences (HESAV), University of Applied Sciences and Arts of Western Switzerland (HES-SO), Av. de Beaumont 21, 1011 Lausanne, Switzerland
| | - I Geerling
- Department of Medical Imaging and Radiation Therapy, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, the Netherlands
| | - J Linneman
- Department of Medical Imaging and Radiation Therapy, Hanze University of Applied Sciences, Petrus Driessenstraat 3, 9714 CA Groningen, the Netherlands
| | - S Staats
- Radiography in Diagnostics, Department of Clinical Sciences, Central University of the Technology, Bloemfontein, South Africa
| | - C Campeanu
- Department of Technical Medical Radiology, School of Health Sciences (HESAV), University of Applied Sciences and Arts of Western Switzerland (HES-SO), Av. de Beaumont 21, 1011 Lausanne, Switzerland
| |
Collapse
|
2
|
Abela N, Guilherme Couto J, Zarb F, Mizzi D. Evaluating the use of anti-scatter grids in adult knee radiography. Radiography (Lond) 2022; 28:663-667. [PMID: 35623269 DOI: 10.1016/j.radi.2022.05.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2021] [Revised: 05/04/2022] [Accepted: 05/09/2022] [Indexed: 10/18/2022]
Abstract
INTRODUCTION Anti-scatter grids efficiently reduce scatter radiation from reaching the imaging receptor, enhancing image quality; however, the patient radiation dose increases in the process. There is disagreement regarding the thickness thresholds for which anti-scatter grids are beneficial. This study aims to establish a thickness threshold for the use of anti-scatter grids to optimise adult knee radiography. METHODS The study consisted of two phases. In Phase 1 phantom knee radiographs were acquired at varying thicknesses (10-16 cm) and tube voltages (60-80 kV). For each thickness and tube voltage, images with and without an anti-scatter grid were obtained. In Phase 2, two radiologists and three radiographers, evaluated the image quality of these images. Visual Grading Analysis (VGA) scores were analysed using Visual Grading Characteristics (VGC) based on the visualisation of five anatomic criteria. RESULTS The average DAP decreased by 72.1% and mAs by 73.1% when removing the anti-scatter grid. The VGC revealed that overall images taken with an anti-scatter grid have better image quality (AUC ≥0.5 for all comparisons). However, the anti-scatter grids could be removed for thicknesses 10, 12 and 14 cm in conjunction with using 80 kVp,. CONCLUSION Anti-scatter grids can be removed when imaging adult knees between 10 and 12 cm using any kVp setting since the radiation dose is reduced without significantly affecting image quality. For thicknesses >12 cm, the use of anti-scatter grids significantly improves image quality; however, the radiation dose to the patient is increased. The exception is at 14 cm used with 80 kVp, where changes in image quality were insignificant. IMPLICATIONS FOR PRACTICE Optimisation by removing anti-scatter grids in adult knee radiography seems beneficial below 12 cm thickness with any kVp value. Since the average knee thickness ranges between 10 and 13 cm, anti-scatter grid can be removed for most patients. Nevertheless, further studies are recommended to test if this phantom-based threshold applies to human subjects.
Collapse
Affiliation(s)
- N Abela
- Radiography Department, Faculty of Health Sciences, University of Malta, Msida, MSD2090, Malta.
| | - J Guilherme Couto
- Radiography Department, Faculty of Health Sciences, University of Malta, Msida, MSD2090, Malta.
| | - F Zarb
- Radiography Department, Faculty of Health Sciences, University of Malta, Msida, MSD2090, Malta.
| | - D Mizzi
- Radiography Department, Faculty of Health Sciences, University of Malta, Msida, MSD2090, Malta.
| |
Collapse
|
3
|
Singh T, Muscroft N, Collier N, England A. A comparison of effective dose and risk for different collimation options used in AP shoulder radiography. Radiography (Lond) 2021; 28:394-399. [PMID: 34887196 DOI: 10.1016/j.radi.2021.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 11/01/2021] [Accepted: 11/19/2021] [Indexed: 11/15/2022]
Abstract
INTRODUCTION Radiography forms the cornerstone of the evaluation of shoulder disorders. While the benefits of radiography exceed the risks, there continues to be a compelling case for reduction of radiation exposure from diagnostic radiography. The aim of this project was to evaluate the radiation dose and risk for a variety of collimation settings used during anteroposterior (AP) shoulder radiography. METHODS This was a phantom based study where an ATOM adult dosimetry phantom was loaded with 272 thermoluminescent dosimeters (TLDs). Following loading, the phantom was setup for an AP shoulder X-ray projection with standard 25 × 30 cm rectangular collimation. The phantom was exposed three times and then the TLDs were removed and read. The experiment was repeated using a diamond shaped collimation and rectangular collimation with a minimum field of view to portray only relevant anatomy. Using the TLD dose measurements the effective doses and radiation risks were determined and compared. RESULTS As expected, organs neighbouring the shoulder experienced the highest absorbed doses (greater than 0.01 mGy); these organs included breast, lung and thyroid gland. The effective doses for standard rectangular, small rectangular and diamond collimation were 0.011, 0.008 and 0.016 mSv, respectively. When compared to standard collimation, a small field of view reduced effective dose by 27.3% and when moving to a diamond shape there was a 45.5% increase. The differences are likely driven by differences in the coverage of the radiosensitive lung and breast tissue. CONCLUSION By utilising a variety of different collimation settings, effective dose can be reduced. Reducing the radiation dose is both financially beneficial and results in a lower stochastic risk for patients. Image quality must also be considered when choosing different collimation settings. It stands to reason that by reducing the field size, dose will be reduced, and our study has served to quantify the effects in a practical situation. IMPLICATIONS FOR PRACTICE The utilisation of smaller/tight collimation is recommended as it offers the lowest dose when compared with other types of collimations. Although well-known this study serves to remind practitioners of the practical importance of collimation and is associated effect on effective dose and risk.
Collapse
Affiliation(s)
- T Singh
- School of Allied Health Professions, Keele University, Keele, Staffordshire, UK
| | - N Muscroft
- Warrington & Halton Teaching Hospitals NHS Trust, Warrington, UK
| | - N Collier
- Lancashire Teaching Hospitals NHS Trust, Preston, UK
| | - A England
- School of Allied Health Professions, Keele University, Keele, Staffordshire, UK; Discipline of Medical Imaging, School of Medicine, University College Cork, Ireland.
| |
Collapse
|
4
|
Steffensen C, Trypis G, Mander GTW, Munn Z. Optimisation of radiographic acquisition parameters for direct digital radiography: A systematic review. Radiography (Lond) 2020; 27:663-672. [PMID: 32948453 DOI: 10.1016/j.radi.2020.08.012] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 08/25/2020] [Accepted: 08/28/2020] [Indexed: 11/16/2022]
Abstract
INTRODUCTION The objective of this systematic review was to uncover and synthesise all available literature regarding appropriate acquisition parameters for direct digital radiography. It sought to either confirm current practices as optimal, or to uncover practices that may produce more optimised results. METHODS A comprehensive search of published and unpublished literature was undertaken to find studies that evaluated how adjustment of different acquisition parameters affected subjective image quality and patient radiation dose. Eight hundred and fifty-eight studies were retrieved for title and abstract screening. Eighty-nine studies were retrieved for full-text screening, and 23 were included for review and methodological quality screening. RESULTS Narrative synthesis of the 23 included studies revealed limited evidence to guide any potential change or acceptance of currently accepted best practice. Meta-analysis was unable to be performed for any of the included studies due to high levels of methodological heterogeneity. A key finding of this review was that the goals of optimisation research varied greatly across the included studies. CONCLUSION Significant methodological heterogeneity in the included studies limited the number of clinically relevant findings that would give evidence to an acceptance of, or suggest changes to, currently accepted best practice. Improving consistency in approach across future works of technique optimisation will ensure future systematic reviews will be able to provide strong evidence and meta-analysis will be able to be performed. IMPLICATIONS FOR CLINICAL PRACTICE This review highlights that in the literature, studies of optimisation of radiographic acquisition parameters have varying goals. This methodological heterogeneity limits the applicability of systematic reviews and precludes the use of meta-analysis. The authors recommend that a framework for optimisation research be produced as a priority to help improve homogeneity in future research.
Collapse
Affiliation(s)
- C Steffensen
- Philips Australia and New Zealand, North Ryde, Australia; JBI, The University of Adelaide, Adelaide, Australia.
| | - G Trypis
- Department of Medical Imaging, Sunshine Coast University Hospital, Sunshine Coast Hospital and Health Service, Birtinya, Australia
| | - G T W Mander
- Department of Medical Imaging, Toowoomba Hospital, Darling Downs Health, Toowoomba, Australia; JBI, The University of Adelaide, Adelaide, Australia
| | - Z Munn
- JBI, The University of Adelaide, Adelaide, Australia
| |
Collapse
|
5
|
Abstract
Antiscatter grids improve the X-ray image contrast at a cost of patient radiation doses. The choice of appropriate grid or its removal requires a good knowledge of grid characteristics, especially for pediatric digital imaging. The aim of this work is to understand the relation between grid performance parameters and some numerical image quality metrics for digital radiological examinations. The grid parameters such as bucky factor (BF), selectivity (Σ), Contrast improvement factor (CIF), and signal-to-noise improvement factor (SIF) were determined following the measurements of primary, scatter, and total radiations with a digital fluoroscopic system for the thicknesses of 5, 10, 15, 20, and 25 cm polymethyl methacrylate blocks at the tube voltages of 70, 90, and 120 kVp. Image contrast for low- and high-contrast objects and high-contrast spatial resolution were measured with simple phantoms using the same scatter thicknesses and tube voltages. BF and SIF values were also calculated from the images obtained with and without grids. The correlation coefficients between BF values obtained using two approaches (grid parameters and image quality metrics) were in good agreement. Proposed approach provides a quick and practical way of estimating grid performance for different digital fluoroscopic examinations.
Collapse
Affiliation(s)
- Dogan Bor
- Department of Physics Engineering, Faculty of Engineering, Ankara University, 06100 Ankara, Turkey
| | - Ozlem Birgul
- Department of Medical Physics, Institute of Nuclear Sciences, Ankara University, 06100 Ankara, Turkey
| | - Umran Onal
- Department of Medical Physics, Institute of Nuclear Sciences, Ankara University, 06100 Ankara, Turkey
| | - Turan Olgar
- Department of Physics Engineering, Faculty of Engineering, Ankara University, 06100 Ankara, Turkey
| |
Collapse
|
6
|
Effects of tube potential and scatter rejection on image quality and effective dose in digital chest X-ray examination: An anthropomorphic phantom study. Radiography (Lond) 2013. [DOI: 10.1016/j.radi.2013.07.007] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
7
|
Moore CS, Liney GP, Beavis AW, Saunderson JR. A method to produce and validate a digitally reconstructed radiograph-based computer simulation for optimisation of chest radiographs acquired with a computed radiography imaging system. Br J Radiol 2011; 84:890-902. [PMID: 21933979 PMCID: PMC3473768 DOI: 10.1259/bjr/30125639] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2010] [Revised: 06/29/2010] [Accepted: 06/30/2010] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES The purpose of this study was to develop and validate a computer model to produce realistic simulated computed radiography (CR) chest images using CT data sets of real patients. METHODS Anatomical noise, which is the limiting factor in determining pathology in chest radiography, is realistically simulated by the CT data, and frequency-dependent noise has been added post-digitally reconstructed radiograph (DRR) generation to simulate exposure reduction. Realistic scatter and scatter fractions were measured in images of a chest phantom acquired on the CR system simulated by the computer model and added post-DRR calculation. RESULTS The model has been validated with a phantom and patients and shown to provide predictions of signal-to-noise ratios (SNRs), tissue-to-rib ratios (TRRs: a measure of soft tissue pixel value to that of rib) and pixel value histograms that lie within the range of values measured with patients and the phantom. The maximum difference in measured SNR to that calculated was 10%. TRR values differed by a maximum of 1.3%. CONCLUSION Experienced image evaluators have responded positively to the DRR images, are satisfied they contain adequate anatomical features and have deemed them clinically acceptable. Therefore, the computer model can be used by image evaluators to grade chest images presented at different tube potentials and doses in order to optimise image quality and patient dose for clinical CR chest radiographs without the need for repeat patient exposures.
Collapse
Affiliation(s)
- C S Moore
- Radiation Physics Department, Queen's Centre for Oncology and Haematology, Castle Hill Hospital, Hull & East Yorkshire Hospitals, Castle Road, Hull, UK.
| | | | | | | |
Collapse
|
8
|
Image quality in the anteroposterior cervical spine radiograph: Comparison between moving, stationary and non-grid techniques in a lamb neck. Radiography (Lond) 2011. [DOI: 10.1016/j.radi.2010.12.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
9
|
Goyal N, Rachapalli V, Burns H, Lloyd DC. Cervical spine imaging in trauma: Does the use of grid and filter combination improve visualisation of the cervicothoracic junction? Radiography (Lond) 2011. [DOI: 10.1016/j.radi.2010.04.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
10
|
Lo WY, Hornof WJ, Zwingenberger AL, Robertson ID. Multiscale image processing and antiscatter grids in digital radiography. Vet Radiol Ultrasound 2009; 50:569-76. [PMID: 19999338 DOI: 10.1111/j.1740-8261.2009.01585.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
Abstract
Scatter radiation is a source of noise and results in decreased signal-to-noise ratio and thus decreased image quality in digital radiography. We determined subjectively whether a digitally processed image made without a grid would be of similar quality to an image made with a grid but without image processing. Additionally the effects of exposure dose and of a using a grid with digital radiography on overall image quality were studied. Thoracic and abdominal radiographs of five dogs of various sizes were made. Four acquisition techniques were included (1) with a grid, standard exposure dose, digital image processing; (2) without a grid, standard exposure dose, digital image processing; (3) without a grid, half the exposure dose, digital image processing; and (4) with a grid, standard exposure dose, no digital image processing (to mimic a film-screen radiograph). Full-size radiographs as well as magnified images of specific anatomic regions were generated. Nine reviewers rated the overall image quality subjectively using a five-point scale. All digitally processed radiographs had higher overall scores than nondigitally processed radiographs regardless of patient size, exposure dose, or use of a grid. The images made at half the exposure dose had a slightly lower quality than those made at full dose, but this was only statistically significant in magnified images. Using a grid with digital image processing led to a slight but statistically significant increase in overall quality when compared with digitally processed images made without a grid but whether this increase in quality is clinically significant is unknown.
Collapse
Affiliation(s)
- Winnie Y Lo
- Veterinary Medical Teaching Hospital, School of Veterinary Medicine, University of California, Davis, 1 Shields Avenue, Davis, CA 95616, USA.
| | | | | | | |
Collapse
|
11
|
Matthews K, Brennan PC. Optimisation of X-ray examinations: General principles and an Irish perspective. Radiography (Lond) 2009. [DOI: 10.1016/j.radi.2008.07.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
12
|
Moore CS, Saunderson JR, Beavis AW. Investigating the exposure class of a computed radiography system for optimisation of physical image quality for chest radiography. Br J Radiol 2009; 82:705-10. [PMID: 19221185 DOI: 10.1259/bjr/27942950] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The purpose of this study was to investigate whether the exposure (speed) class (EC) of an Agfa computed radiography (CR) system could be used to optimise chest radiography. The frequency-dependent normalised noise-power spectra (NNPS(f)) were determined for a range of EC settings (25-1200) for a receptor dose of 4 microGy. Signal-to-noise ratios (SNRs) were measured in the lung, heart and diaphragm areas of a chest phantom with ECs of 400 and 600 at four tube voltages (60, 75, 90 and 125 kVp). As anatomical background can be a factor in detection of lung nodules, a tissue to rib ratio (TRR), which measures the ratio of pixel values in the nodule to that of rib, was measured in the lung region of the phantom to assess the suppression of the rib at ECs of 400 and 600. The NNPS(f) at ECs lower than 400 was relatively high. The NNPS(f) at EC 600 was found to be 7% lower when averaged over all frequencies than that at EC 400. The statistical significance of this difference was verified. The EC 800 and EC 1200 settings offered no extra advantages in terms of lowering frequency-dependent noise. The EC 600 setting offered improvements in SNR of between 10% and 18% in the lung, 11% and 16% in the heart, and 15% and 20% in the diaphragm compared with EC 400. Statistical analysis verified the significant difference. The EC 600 setting increased the TRR, thereby helping to suppress rib. This work indicates that an exposure class setting of 600 is the most appropriate for standard chest radiography, but clinical verification is required.
Collapse
Affiliation(s)
- C S Moore
- Radiation Physics Department, Hull and East Yorkshire Hospitals, Oncology Centre, Castle Hill Hospital, Cottingham, East Yorkshire.
| | | | | |
Collapse
|
13
|
Moore CS, Beavis AW, Saunderson JR. Investigation of optimum X-ray beam tube voltage and filtration for chest radiography with a computed radiography system. Br J Radiol 2008; 81:771-7. [PMID: 18662964 DOI: 10.1259/bjr/21963665] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
The purpose of this study was to determine the optimum tube voltage and amount of added copper (Cu) filtration for processed chest radiographs obtained with an Agfa 75.0 Computed Radiography (CR) system. The contrast-to-noise ratio (CNR) was measured in the lung, heart/spine and diaphragm compartments of a validated chest phantom using various tube voltages and amounts of Cu filtration. The CNR was derived as a function of air kerma at the CR plate and with the effective dose. As rib contrast can interfere with detection of nodules in chest radiography, a tissue-to-rib ratio (TRR) was derived to investigate which tube voltages suppress the contrast of rib. Although processing algorithms affect the signal and noise in a way that is hard to predict, we found that, for a given set of processing parameters, the CNR was related to the plate air kerma and effective dose in a logarithmic manner (all R(2) >or=0.97). For imaging of the lung region, a low voltage (60 kVp) produced the highest CNR, whereas a high voltage (125 kVp) produced the highest TRR. In the heart/spine region, 80-125 kVp produced the highest CNR, while in the diaphragm region 60-90 kVp produced the highest CNR. For chest radiography with this CR system, the optimal tube voltage depends upon the region of interest. Of the filters tested, a 0.1 mm Cu thickness was found to provide a statistically significant increase in the CNR in the diaphragm region with tube potentials of 60 kVp and 80 kVp, without affecting the CNR in the other anatomical compartments.
Collapse
Affiliation(s)
- C S Moore
- Radiation Physics Department, Hull & East Yorkshire Hospitals, Princess Royal Hospital, Saltshouse Road, Kingston Upon Hull, UK.
| | | | | |
Collapse
|