1
|
A pH-sensitive field-effect transistor for monitoring of cancer cell external acid environment. Talanta 2022; 252:123764. [PMID: 35969927 DOI: 10.1016/j.talanta.2022.123764] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2022] [Revised: 07/19/2022] [Accepted: 07/20/2022] [Indexed: 11/19/2022]
|
2
|
A Sensitivity-Enhanced Electrolyte-Gated Graphene Field-Effect Transistor Biosensor by Acoustic Tweezers. MICROMACHINES 2021; 12:mi12101238. [PMID: 34683289 PMCID: PMC8541680 DOI: 10.3390/mi12101238] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 10/09/2021] [Accepted: 10/11/2021] [Indexed: 12/31/2022]
Abstract
Low-abundance biomolecule detection is very crucial in many biological and medical applications. In this paper, we present a novel electrolyte-gated graphene field-effect transistor (EGFET) biosensor consisting of acoustic tweezers to increase the sensitivity. The acoustic tweezers are based on a high-frequency bulk acoustic resonator with thousands of MHz, which has excellent ability to concentrate nanoparticles. The operating principle of the acoustic tweezers to concentrate biomolecules is analyzed and verified by experiments. After the actuation of acoustic tweezers for 10 min, the IgG molecules are accumulated onto the graphene. The sensitivities of the EGFET biosensor with accumulation and without accumulation are compared. As a result, the sensitivity of the graphene-based biosensor is remarkably increased using SMR as the biomolecule concentrator. Since the device has advantages such as miniaturized size, low reagent consumption, high sensitivity, and rapid detection, we expect it to be readily applied to many biological and medical applications.
Collapse
|
3
|
Raghavan VS, O'Driscoll B, Bloor JM, Li B, Katare P, Sethi J, Gorthi SS, Jenkins D. Emerging graphene-based sensors for the detection of food adulterants and toxicants - A review. Food Chem 2021; 355:129547. [PMID: 33773454 DOI: 10.1016/j.foodchem.2021.129547] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2020] [Revised: 02/25/2021] [Accepted: 03/04/2021] [Indexed: 02/06/2023]
Abstract
The detection of food adulterants and toxicants can prevent a large variety of adverse health conditions for the global population. Through the process of rapid sensing enabled by deploying novel and robust sensors, the food industry can assist in the detection of adulterants and toxicants at trace levels. Sensor platforms which exploit graphene-based nanomaterials satisfy this requirement due to outstanding electrical, optical and thermal properties. The materials' facile conjugation with linkers and biomolecules along with the option for further enhancement using nanoparticles results in highly sensitive and selective sensing characteristics. This review highlights novel applications of graphene derivatives for detection covering three important approaches; optical, electrical (field-effect) and electrochemical sensing. Suitable graphene-based sensors for portable devices as point-of-need platforms are also presented. The future scope of these sensors is discussed to showcase how these emerging techniques will disrupt the food detection sector for years to come.
Collapse
Affiliation(s)
- Vikram Srinivasa Raghavan
- Optics and Microfluidics Instrumentation Lab, Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore 560012, India.
| | - Benjamin O'Driscoll
- Wolfson Nanomaterials & Devices Laboratory, School of Engineering, Computing and Mathematics, Plymouth University, Devon PL4 8AA, UK
| | - J M Bloor
- Wolfson Nanomaterials & Devices Laboratory, School of Engineering, Computing and Mathematics, Plymouth University, Devon PL4 8AA, UK
| | - Bing Li
- Department of Brain Sciences, Imperial College, London W12 0NN, UK
| | - Prateek Katare
- Optics and Microfluidics Instrumentation Lab, Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore 560012, India
| | - Jagriti Sethi
- Wolfson Nanomaterials & Devices Laboratory, School of Engineering, Computing and Mathematics, Plymouth University, Devon PL4 8AA, UK
| | - Sai Siva Gorthi
- Optics and Microfluidics Instrumentation Lab, Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore 560012, India
| | - David Jenkins
- Wolfson Nanomaterials & Devices Laboratory, School of Engineering, Computing and Mathematics, Plymouth University, Devon PL4 8AA, UK
| |
Collapse
|
4
|
Béraud A, Sauvage M, Bazán CM, Tie M, Bencherif A, Bouilly D. Graphene field-effect transistors as bioanalytical sensors: design, operation and performance. Analyst 2020; 146:403-428. [PMID: 33215184 DOI: 10.1039/d0an01661f] [Citation(s) in RCA: 62] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
Abstract
Graphene field-effect transistors (GFETs) are emerging as bioanalytical sensors, in which their responsive electrical conductance is used to perform quantitative analyses of biologically-relevant molecules such as DNA, proteins, ions and small molecules. This review provides a detailed evaluation of reported approaches in the design, operation and performance assessment of GFET biosensors. We first dissect key design elements of these devices, along with most common approaches for their fabrication. We compare possible modes of operation of GFETs as sensors, including transfer curves, output curves and time series as well as their integration in real-time or a posteriori protocols. Finally, we review performance metrics reported for the detection and quantification of bioanalytes, and discuss limitations and best practices to optimize the use of GFETs as bioanalytical sensors.
Collapse
Affiliation(s)
- Anouk Béraud
- Institute for Research in Immunology and Cancer (IRIC), Université de Montréal, Montréal, Canada.
| | | | | | | | | | | |
Collapse
|
5
|
Xu L, Wen Y, Pandit S, Mokkapati VRSS, Mijakovic I, Li Y, Ding M, Ren S, Li W, Liu G. Graphene-based biosensors for the detection of prostate cancer protein biomarkers: a review. BMC Chem 2019; 13:112. [PMID: 31508598 PMCID: PMC6720397 DOI: 10.1186/s13065-019-0611-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2018] [Accepted: 07/15/2019] [Indexed: 02/07/2023] Open
Abstract
Prostate cancer (PC) is the sixth most common cancer type in the world, which causes approximately 10% of total cancer fatalities. The detection of protein biomarkers in body fluids is the key topic for the diagnosis and prognosis of PC. Highly sensitive screening of PC is the most effective approach for reducing mortality. Thus, there are a growing number of literature that recognizes the importance of new technologies for early diagnosis of PC. Graphene is playing an important role in the biosensor field with remarkable physical, optical, electrochemical and magnetic properties. Many recent studies demonstrated the potential of graphene materials for sensitive detection of protein biomarkers. In this review, the graphene-based biosensors toward PC analysis are mainly discussed in two groups: Firstly, novel biosensor interfaces were constructed through the modification of graphene materials onto sensor surfaces. Secondly, ingenious signal amplification strategies were developed using graphene materials as catalysts or carriers. Graphene-based biosensors have exhibited remarkable performance with high sensitivities, wide detection ranges, and long-term stabilities.
Collapse
Affiliation(s)
- Li Xu
- 1Laboratory of Biometrory, Division of Chemistry and Ionizing Radiation Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, 201203 People's Republic of China.,2Division of Systems and Synthetic Biology, Department of Biology and Biological Engineering, Chalmers University of Technology, 41126 Gothenburg, Sweden
| | - Yanli Wen
- 1Laboratory of Biometrory, Division of Chemistry and Ionizing Radiation Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, 201203 People's Republic of China
| | - Santosh Pandit
- 2Division of Systems and Synthetic Biology, Department of Biology and Biological Engineering, Chalmers University of Technology, 41126 Gothenburg, Sweden
| | - Venkata R S S Mokkapati
- 2Division of Systems and Synthetic Biology, Department of Biology and Biological Engineering, Chalmers University of Technology, 41126 Gothenburg, Sweden
| | - Ivan Mijakovic
- 2Division of Systems and Synthetic Biology, Department of Biology and Biological Engineering, Chalmers University of Technology, 41126 Gothenburg, Sweden.,3The Novo Nordisk Foundation Center for Biosustainability, Technical University of Denmark, 2800 Lyngby, Denmark
| | - Yan Li
- 1Laboratory of Biometrory, Division of Chemistry and Ionizing Radiation Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, 201203 People's Republic of China
| | - Min Ding
- 1Laboratory of Biometrory, Division of Chemistry and Ionizing Radiation Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, 201203 People's Republic of China
| | - Shuzhen Ren
- 1Laboratory of Biometrory, Division of Chemistry and Ionizing Radiation Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, 201203 People's Republic of China
| | - Wen Li
- 1Laboratory of Biometrory, Division of Chemistry and Ionizing Radiation Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, 201203 People's Republic of China
| | - Gang Liu
- 1Laboratory of Biometrory, Division of Chemistry and Ionizing Radiation Measurement Technology, Shanghai Institute of Measurement and Testing Technology, Shanghai, 201203 People's Republic of China
| |
Collapse
|
6
|
Panwar N, Soehartono AM, Chan KK, Zeng S, Xu G, Qu J, Coquet P, Yong KT, Chen X. Nanocarbons for Biology and Medicine: Sensing, Imaging, and Drug Delivery. Chem Rev 2019; 119:9559-9656. [DOI: 10.1021/acs.chemrev.9b00099] [Citation(s) in RCA: 238] [Impact Index Per Article: 47.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Nishtha Panwar
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Alana Mauluidy Soehartono
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Kok Ken Chan
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Shuwen Zeng
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
- CINTRA CNRS/NTU/THALES, UMI 3288, Research Techno Plaza, 50 Nanyang Drive, Border X Block, Singapore 637553, Singapore
| | - Gaixia Xu
- Key Laboratory of Optoelectronics Devices and Systems of Ministry of Education/Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, P. R. China
| | - Junle Qu
- Key Laboratory of Optoelectronics Devices and Systems of Ministry of Education/Guangdong Province, College of Optoelectronic Engineering, Shenzhen University, Shenzhen 518060, P. R. China
| | - Philippe Coquet
- CINTRA CNRS/NTU/THALES, UMI 3288, Research Techno Plaza, 50 Nanyang Drive, Border X Block, Singapore 637553, Singapore
- Institut d’Electronique, de Microélectronique et de Nanotechnologie (IEMN), CNRS UMR 8520—Université de Lille, 59650 Villeneuve d’Ascq, France
| | - Ken-Tye Yong
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore 639798, Singapore
| | - Xiaoyuan Chen
- Laboratory of Molecular Imaging and Nanomedicine, National Institute of Biomedical Imaging and Bioengineering, National Institutes of Health, Bethesda, Maryland 20892, United States
| |
Collapse
|
7
|
Taniselass S, Arshad MM, Gopinath SC. Graphene-based electrochemical biosensors for monitoring noncommunicable disease biomarkers. Biosens Bioelectron 2019; 130:276-292. [DOI: 10.1016/j.bios.2019.01.047] [Citation(s) in RCA: 134] [Impact Index Per Article: 26.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2018] [Revised: 01/16/2019] [Accepted: 01/18/2019] [Indexed: 02/07/2023]
|
8
|
Toral-Lopez A, Marin EG, Gonzalez-Medina JM, Romero FJ, Ruiz FG, Morales DP, Rodriguez N, Godoy A. Assessment of three electrolyte-molecule electrostatic interaction models for 2D material based BioFETs. NANOSCALE ADVANCES 2019; 1:1077-1085. [PMID: 36133192 PMCID: PMC9473221 DOI: 10.1039/c8na00109j] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2018] [Accepted: 11/28/2018] [Indexed: 06/01/2023]
Abstract
BioFETs based on two-dimensional materials (2DMs) offer a unique opportunity to enhance, at a low cost, the sensitivity of current biosensors enabling the design of compact devices compatible with standard CMOS technology. The unique combination of large exposed surface areas and minimal thicknesses of 2DMs is an outstanding feature for these devices, and the assessment of their behaviour requires combined experimental and theoretical efforts. In this work we present a 2D-material based BioFET simulator including complex electrolyte reactions and analysing different models for the electrolyte-molecule interaction. These models describe how the molecular charge is screened by the electrolyte ions when their distributions are modified. The electrolyte simulation is validated against experimental results as well as against the analytical predictions of the Debye-Hückel approximation. The role of the electrolyte charge screening as well as the impact of the interaction model on the device responsivity are analysed in detail. The results are discussed in order to conclude about the consequences of employing different interaction approximations for the simulation of BioFETs and more generally on the correct modelling of biomolecule-device interaction in BioFETs.
Collapse
Affiliation(s)
- A Toral-Lopez
- Dpto. Electrónica, Fac. Ciencias, Universidad de Granada 18071 Spain
| | - E G Marin
- Dpto. Electrónica, Fac. Ciencias, Universidad de Granada 18071 Spain
- Dipartimento di Ingegneria dell'Informazione, Università di Pisa 56122 Pisa Italy
| | | | - F J Romero
- Dpto. Electrónica, Fac. Ciencias, Universidad de Granada 18071 Spain
| | - F G Ruiz
- Dpto. Electrónica, Fac. Ciencias, Universidad de Granada 18071 Spain
| | - D P Morales
- Dpto. Electrónica, Fac. Ciencias, Universidad de Granada 18071 Spain
| | - N Rodriguez
- Dpto. Electrónica, Fac. Ciencias, Universidad de Granada 18071 Spain
| | - A Godoy
- Dpto. Electrónica, Fac. Ciencias, Universidad de Granada 18071 Spain
| |
Collapse
|
9
|
Rodríguez SJ, Albanesi EA. Electronic transport in a graphene single layer: application in amino acid sensing. Phys Chem Chem Phys 2019; 21:597-606. [PMID: 30543232 DOI: 10.1039/c8cp05093g] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/15/2023]
Abstract
We modeled a type of field-effect transistor device based on graphene for the recognition of amino acids with a potential application in the building of a protein sequencer. The theoretical model used was a combination of density functional theory (DFT) with the non-equilibrium Green's function (NEGF) in order to describe the coherent transport in molecular devices. First, we studied the physisorption of each amino acid on a graphene sheet and we reported the adsorption energy, the adsorption distances, the equilibrium configuration and the charge transfer of ten amino acids that can be considered as representative of all of the amino acids: histidine (His), alanine (Ala), aspartic acid (Asp), tyrosine (Tyr), arginine (Arg), glutamic acid (Glu), glycine (Gly), phenylalanine (Phe), proline (Pro) and lysine (Lys). As a result, significant differences were found in the density of states (DOS) after adsorption and there was a change in the semi-metallic character of the graphene due to the lysine and arginine interactions. Furthermore, we noticed changes in the electrical characteristics of the devices, as the amino acids adsorbed onto the surface of the graphene. The curves of current vs. bias voltage (I-Vb) display a distinct response for each amino acid, i.e. the I-Vb curves produce a characteristic footprint for each amino acid. We identified a possible rectification mechanism related to the voltage profile asymmetry, where the amino acids can control the transport characteristics in the device, i.e. Lys and Phe amino acids physisorbed on graphene act as a molecular diode, where electrons can easily flow in one direction and decrease in the other. This may be promising for the prospect of biosensors: graphene could be used as an amino acid detector.
Collapse
Affiliation(s)
- Sindy J Rodríguez
- Instituto de Física del Litoral (CONICET-UNL), Güemes 3450, Santa Fe, Argentina.
| | | |
Collapse
|
10
|
Lawal AT. Progress in utilisation of graphene for electrochemical biosensors. Biosens Bioelectron 2018; 106:149-178. [PMID: 29414083 DOI: 10.1016/j.bios.2018.01.030] [Citation(s) in RCA: 94] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2017] [Revised: 01/02/2018] [Accepted: 01/15/2018] [Indexed: 01/02/2023]
Abstract
This review discusses recent graphene (GR) electrochemical biosensor for accurate detection of biomolecules, including glucose, hydrogen peroxide, dopamine, ascorbic acid, uric acid, nicotinamide adenine dinucleotide, DNA, metals and immunosensor through effective immobilization of enzymes, including glucose oxidase, horseradish peroxidase, and haemoglobin. GR-based biosensors exhibited remarkable performance with high sensitivities, wide linear detection ranges, low detection limits, and long-term stabilities. Future challenges for the field include miniaturising biosensors and simplifying mass production are discussed.
Collapse
|
11
|
Jiang WS, Xin W, Chen SN, Li CB, Gao XG, Pan LT, Liu ZB, Tian JG. Microshell Arrays Enhanced Sensitivity in Detection of Specific Antibody for Reduced Graphene Oxide Optical Sensor. SENSORS 2017; 17:s17020221. [PMID: 28125011 PMCID: PMC5336008 DOI: 10.3390/s17020221] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2016] [Revised: 01/14/2017] [Accepted: 01/18/2017] [Indexed: 11/23/2022]
Abstract
Protein-protein interactions play an important role in the investigation of biomolecules. In this paper, we reported on the use of a reduced graphene oxide microshell (RGOM)-based optical biosensor for the determination of goat anti-rabbit IgG. The biosensor was prepared through a self-assembly of monolayers of monodisperse polystyrene microspheres, combined with a high-temperature reduction, in order to decorate the RGOM with rabbit IgG. The periodic microshells allowed a simpler functionalization and modification of RGOM with bioreceptor units, than reduced graphene oxide (RGO). With additional antibody-antigen binding, the RGOM-based biosensor achieved better real-time and label-free detection. The RGOM-based biosensor presented a more satisfactory response to goat anti-rabbit IgG than the RGO-based biosensor. This method is promising for immobilizing biomolecules on graphene surfaces and for the fabrication of biosensors with enhanced sensitivity.
Collapse
Affiliation(s)
- Wen-Shuai Jiang
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
| | - Wei Xin
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
| | - Shao-Nan Chen
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
| | - Cun-Bo Li
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
| | - Xiao-Guang Gao
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
| | - Lei-Ting Pan
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
| | - Zhi-Bo Liu
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
- The 2011 Project Collaborative Innovation Center for Biological Therapy, Nankai University, Tianjin 300071, China.
| | - Jian-Guo Tian
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Teda Applied Physics School and School of Physics, Nankai University, Tianjin 300071, China.
- The 2011 Project Collaborative Innovation Center for Biological Therapy, Nankai University, Tianjin 300071, China.
| |
Collapse
|
12
|
Tran TT, Mulchandani A. Carbon nanotubes and graphene nano field-effect transistor-based biosensors. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.12.002] [Citation(s) in RCA: 107] [Impact Index Per Article: 13.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
13
|
Binder J, Urban JM, Stepniewski R, Strupinski W, Wysmolek A. In situ Raman spectroscopy of the graphene/water interface of a solution-gated field-effect transistor: electron-phonon coupling and spectroelectrochemistry. NANOTECHNOLOGY 2016; 27:045704. [PMID: 26655462 DOI: 10.1088/0957-4484/27/4/045704] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a novel measurement approach which combines the electrical characterization of solution-gated field-effect transistors based on epitaxial bilayer graphene on 4H-SiC (0001) with simultaneous Raman spectroscopy. By changing the gate voltage, we observed Raman signatures related to the resonant electron-phonon coupling. An analysis of these Raman bands enabled the extraction of the geometrical capacitance of the system and an accurate calculation of the Fermi levels for bilayer graphene. An intentional application of higher gate voltages allowed us to trigger electrochemical reactions, which we followed in situ by Raman spectroscopy. The reactions showed a partially reversible character, as indicated by an emergence/disappearance of peaks assigned to C-H and Si-H vibration modes as well as an increase/decrease of the defect-related Raman D band intensity. Our setup provides a highly interesting platform for future spectroelectrochemical research on electrically-induced sorption processes of graphene on the micrometer scale.
Collapse
Affiliation(s)
- J Binder
- Faculty of Physics, University of Warsaw, Pasteura 5, 02-093 Warsaw, Poland
| | | | | | | | | |
Collapse
|
14
|
Abhilash TS, De Alba R, Zhelev N, Craighead HG, Parpia JM. Transfer printing of CVD graphene FETs on patterned substrates. NANOSCALE 2015; 7:14109-14113. [PMID: 26242482 DOI: 10.1039/c5nr03501e] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
We describe a simple and scalable method for the transfer of CVD graphene for the fabrication of field effect transistors. This is a dry process that uses a modified RCA-cleaning step to improve the surface quality. In contrast to conventional fabrication routes where lithographic steps are performed after the transfer, here graphene is transferred to a pre-patterned substrate. The resulting FET devices display nearly zero Dirac voltage, and the contact resistance between the graphene and metal contacts is on the order of 910 ± 340 Ω μm. This approach enables formation of conducting graphene channel lengths up to one millimeter. The resist-free transfer process provides a clean graphene surface that is promising for use in high sensitivity graphene FET biosensors.
Collapse
Affiliation(s)
- T S Abhilash
- Department of Physics, Cornell University, Ithaca, New York 14853, USA.
| | | | | | | | | |
Collapse
|