Zhang K, Li M, Liang H, Wang J, Yang F, Xu S, Abubakar A. Deep feature-domain matching for cardiac-related component separation from a chest electrical impedance tomography image series: proof-of-concept study. Physiol Meas 2022; 43. [PMID: 36265475 DOI: 10.1088/1361-6579/ac9c44] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2022] [Accepted: 10/20/2022] [Indexed: 02/07/2023]
Abstract
Objectives.The cardiac-related component in chest electrical impedance tomography (EIT) measurement is of potential value to pulmonary perfusion monitoring and cardiac function measurement. In a spontaneous breathing case, cardiac-related signals experience serious interference from ventilation-related signals. Traditional cardiac-related signal-separation methods are usually based on certain features of signals. To further improve the separation accuracy, more comprehensive features of the signals should be exploited.Approach.We propose an unsupervised deep-learning method called deep feature-domain matching (DFDM), which exploits the feature-domain similarity of the desired signals and the breath-holding signals. This method is characterized by two sub-steps. In the first step, a novel Siamese network is designed and trained to learn common features of breath-holding signals; in the second step, the Siamese network is used as a feature-matching constraint between the separated signals and the breath-holding signals.Main results.The method is first tested using synthetic data, and the results show satisfactory separation accuracy. The method is then tested using the data of three patients with pulmonary embolism, and the consistency between the separated images and the radionuclide perfusion scanning images is checked qualitatively.Significance.The method uses a lightweight convolutional neural network for fast network training and inference. It is a potential method for dynamic cardiac-related signal separation in clinical settings.
Collapse
Affiliation(s)
- Ke Zhang
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Maokun Li
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Haiqing Liang
- TEDA International Cardiovascular Hospital, Tianjin 300457, People's Republic of China
| | - Juan Wang
- National Laboratory of Pattern Recognition (NLPR), Institute of Automation, Chinese Academy of Sciences, Beijing 100190, People's Republic of China
| | - Fan Yang
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Shenheng Xu
- Department of Electronic Engineering, Beijing National Research Center for Information Science and Technology (BNRist), Institute for Precision Medicine, Tsinghua University, Beijing 100084, People's Republic of China
| | - Aria Abubakar
- Schlumberger, Houston, TX 77056, United States of America
| |
Collapse
|
2
|
Jiang H, Han Y, Zheng X, Fang Q. Roles of electrical impedance tomography in lung transplantation. Front Physiol 2022; 13:986422. [PMID: 36407002 PMCID: PMC9669435 DOI: 10.3389/fphys.2022.986422] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2022] [Accepted: 10/25/2022] [Indexed: 11/06/2022] Open
Abstract
Lung transplantation is the preferred treatment method for patients with end-stage pulmonary disease. However, several factors hinder the progress of lung transplantation, including donor shortages, candidate selection, and various postoperative complications. Electrical impedance tomography (EIT) is a functional imaging tool that can be used to evaluate pulmonary ventilation and perfusion at the bedside. Among patients after lung transplantation, monitoring the graft’s pulmonary function is one of the most concerning issues. The feasible application of EIT in lung transplantation has been reported over the past few years, and this technique has gained increasing interest from multidisciplinary researchers. Nevertheless, physicians still lack knowledge concerning the potential applications of EIT in lung transplantation. We present an updated review of EIT in lung transplantation donors and recipients over the past few years, and discuss the potential use of ventilation- and perfusion-monitoring-based EIT in lung transplantation.
Collapse
Affiliation(s)
| | | | - Xia Zheng
- *Correspondence: Xia Zheng, ; Qiang Fang,
| | - Qiang Fang
- *Correspondence: Xia Zheng, ; Qiang Fang,
| |
Collapse
|
3
|
Mosing M, Cheong JM, Müller B, Böhm S, Hosgood G, Raisis A. Determination of tidal volume by electrical impedance tomography (EIT) after indirect two-point calibration. Physiol Meas 2022; 43. [PMID: 35322796 DOI: 10.1088/1361-6579/ac604a] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2021] [Accepted: 03/23/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE A linear relationship between impedance change (△Z) measured by thoracic electrical impedance tomography (EIT) and tidal volume (VT) has been demonstrated. This study evaluated the agreement between the displayed VT calculated by the EIT software (VTEIT) and spirometry (VTSPIRO) after an indirect two-point calibration. APPROACH The EIT software was programmed to execute a bedside two-point calibration from the subject-specific, linear equation defining the relationship between △Z and VTSPIROand displaying VTEITbreath-by-breath in 20 neutered male, juvenile pigs. After EIT calibration VTs of 8, 12, 16 and 20 mL kg-1were applied to the lungs. VTEITand VTSPIROwere recorded and analysed using Bland-Altman plot for multiple subject measurements. Volumetric capnography (VCap) and spirometry data were explored as components of variance using multiple regression. MAIN RESULTS A mean relative difference (bias) of 0.7% with 95% confidence interval (CI) of -10.4 - 10.7% were found between VTEITand VTSPIROfor the analysed data set. The variance in VTEITcould not be explained by any of the measured VCap or spirometry variables. SIGNIFICANCE The narrow CI estimated in this study allows the conclusion that EIT and its software can be used to measure and accurately convert △Z into mililitre VT at the bedside after applying an indirect two-point calibration.
Collapse
Affiliation(s)
- Martina Mosing
- School of Veterinary and Life Science, Murdoch University, 90 South Street, Perth, 6150, AUSTRALIA
| | | | - Beat Müller
- SenTec AG, Kantonsstrasse 14, Therwil, Basel-Landschaft, 7302, SWITZERLAND
| | - Stephan Böhm
- Rostock University Medical Center, Schillingallee 35, Rostock, Mecklenburg-Vorpommern, 18057, GERMANY
| | - Giselle Hosgood
- Murdoch University, 90 South Street, Murdoch, 6150, AUSTRALIA
| | - Anthea Raisis
- Murdoch University, 90 South Street, Murdoch, 6150, AUSTRALIA
| |
Collapse
|
4
|
Xu M, He H, Long Y. Lung Perfusion Assessment by Bedside Electrical Impedance Tomography in Critically Ill Patients. Front Physiol 2021; 12:748724. [PMID: 34721072 PMCID: PMC8548642 DOI: 10.3389/fphys.2021.748724] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 09/13/2021] [Indexed: 12/02/2022] Open
Abstract
As a portable, radiation-free imaging modality, electrical impedance tomography (EIT) technology has shown promise in the bedside visual assessment of lung perfusion distribution in critically ill patients. The two main methods of EIT for assessing lung perfusion are the pulsatility and conductivity contrast (saline) bolus method. Increasing attention is being paid to the saline bolus EIT method in the evaluation of regional pulmonary perfusion in clinical practice. This study seeks to provide an overview of experimental and clinical studies with the aim of clarifying the progress made in the use of the saline bolus EIT method. Animal studies revealed that the saline bolus EIT method presented good consistency with single-photon emission CT (SPECT) in the evaluation of lung regional perfusion changes in various pathological conditions. Moreover, the saline bolus EIT method has been applied to assess the lung perfusion in a pulmonary embolism and the effect of positive end-expiratory pressure (PEEP) on regional ventilation/perfusion ratio (V/Q) and acute respiratory distress syndrome (ARDS) in several clinical studies. The implementation of saline boluses, data analyses, precision, and cutoff values varied among different studies, and a consensus must be reached regarding the clinical application of the saline bolus EIT method. Further study is required to validate the impact of the described saline bolus EIT method on decision-making, therapeutic management, and outcomes in critically ill patients.
Collapse
Affiliation(s)
- Mengru Xu
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Huaiwu He
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| | - Yun Long
- State Key Laboratory of Complex Severe and Rare Diseases, Department of Critical Care Medicine, Peking Union Medical College, Peking Union Medical College Hospital, Chinese Academy of Medical Sciences, Beijing, China
| |
Collapse
|
5
|
Mosing M, Waldmann AD, Sacks M, Buss P, Boesch JM, Zeiler GE, Hosgood G, Gleed RD, Miller M, Meyer LCR, Böhm SH. What hinders pulmonary gas exchange and changes distribution of ventilation in immobilized white rhinoceroses ( Ceratotherium simum) in lateral recumbency? J Appl Physiol (1985) 2020; 129:1140-1149. [PMID: 33054661 DOI: 10.1152/japplphysiol.00359.2020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
This study used electrical impedance tomography (EIT) measurements of regional ventilation and perfusion to elucidate the reasons for severe gas exchange impairment reported in rhinoceroses during opioid-induced immobilization. EIT values were compared with standard monitoring parameters to establish a new monitoring tool for conservational immobilization and future treatment options. Six male white rhinoceroses were immobilized using etorphine, and EIT ventilation variables, venous admixture, and dead space were measured 30, 40, and 50 min after becoming recumbent in lateral position. Pulmonary perfusion mapping using impedance-enhanced EIT was performed at the end of the study period. The measured impedance (∆Z) by EIT was compared between pulmonary regions using mixed linear models. Measurements of regional ventilation and perfusion revealed a pronounced disproportional shift of ventilation and perfusion toward the nondependent lung. Overall, the dependent lung was minimally ventilated and perfused, but remained aerated with minimal detectable lung collapse. Perfusion was found primarily around the hilum of the nondependent lung and was minimal in the periphery of the nondependent and the entire dependent lung. These shifts can explain the high amount of venous admixture and physiological dead space found in this study. Breath holding redistributed ventilation toward dependent and ventral lung areas. The findings of this study reveal important pathophysiological insights into the changes in lung ventilation and perfusion during immobilization of white rhinoceroses. These novel insights might induce a search for better therapeutic options and is establishing EIT as a promising monitoring tool for large animals in the field.NEW & NOTEWORTHY Electrical impedance tomography measurements of regional ventilation and perfusion applied to etorphine-immobilized white rhinoceroses in lateral recumbency revealed a pronounced disproportional shift of the measured ventilation and perfusion toward the nondependent lung. The dependent lung was minimally ventilated and perfused, but still aerated. Perfusion was found primarily around the hilum of the nondependent lung. These shifts can explain the gas exchange impairments found in this study. Breath holding can redistribute ventilation.
Collapse
Affiliation(s)
- Martina Mosing
- School of Veterinary Medicine, College of Science, Health, Engineering and Education, Murdoch University, Perth, Australia
| | - Andreas D Waldmann
- Department of Anesthesiology and Intensive Care Medicine, Rostock University Medical Center, Rostock, Germany
| | - Muriel Sacks
- School of Veterinary Medicine, College of Science, Health, Engineering and Education, Murdoch University, Perth, Australia
| | - Peter Buss
- Veterinary Wildlife Services, South African National Parks, Kruger National Park, Skukuza, South Africa
| | - Jordyn M Boesch
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York
| | - Gareth E Zeiler
- Department of Companion Animal Clinical Studies, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, South Africa.,Centre for Veterinary Wildlife Studies and Department of Paraclinical Studies, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, South Africa
| | - Giselle Hosgood
- School of Veterinary Medicine, College of Science, Health, Engineering and Education, Murdoch University, Perth, Australia
| | - Robin D Gleed
- Department of Clinical Sciences, College of Veterinary Medicine, Cornell University, Ithaca, New York
| | - Michele Miller
- Department of Science and Technology-National Research Foundation Centre of Excellence for Biomedical TB Research, South African Medical Research Council Centre for Tuberculosis Research, Division of Molecular Biology and Human Genetics, Faculty of Medicine and Health Sciences, Stellenbosch University, Cape Town, South Africa
| | - Leith C R Meyer
- Centre for Veterinary Wildlife Studies and Department of Paraclinical Studies, Faculty of Veterinary Science, University of Pretoria, Onderstepoort, South Africa
| | - Stephan H Böhm
- Department of Anesthesiology and Intensive Care Medicine, Rostock University Medical Center, Rostock, Germany
| |
Collapse
|
6
|
Electrical Impedance Tomography for Cardio-Pulmonary Monitoring. J Clin Med 2019; 8:jcm8081176. [PMID: 31394721 PMCID: PMC6722958 DOI: 10.3390/jcm8081176] [Citation(s) in RCA: 56] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2019] [Revised: 08/05/2019] [Accepted: 08/06/2019] [Indexed: 12/14/2022] Open
Abstract
Electrical impedance tomography (EIT) is a bedside monitoring tool that noninvasively visualizes local ventilation and arguably lung perfusion distribution. This article reviews and discusses both methodological and clinical aspects of thoracic EIT. Initially, investigators addressed the validation of EIT to measure regional ventilation. Current studies focus mainly on its clinical applications to quantify lung collapse, tidal recruitment, and lung overdistension to titrate positive end-expiratory pressure (PEEP) and tidal volume. In addition, EIT may help to detect pneumothorax. Recent studies evaluated EIT as a tool to measure regional lung perfusion. Indicator-free EIT measurements might be sufficient to continuously measure cardiac stroke volume. The use of a contrast agent such as saline might be required to assess regional lung perfusion. As a result, EIT-based monitoring of regional ventilation and lung perfusion may visualize local ventilation and perfusion matching, which can be helpful in the treatment of patients with acute respiratory distress syndrome (ARDS).
Collapse
|
7
|
Krueger-Ziolek S, Schullcke B, Gong B, Müller-Lisse U, Moeller K. EIT based pulsatile impedance monitoring during spontaneous breathing in cystic fibrosis. Physiol Meas 2018; 38:1214-1225. [PMID: 28530203 DOI: 10.1088/1361-6579/aa69d5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Evaluating the lung function in patients with obstructive lung disease by electrical impedance tomography (EIT) usually requires breathing maneuvers containing deep inspirations and forced expirations. Since these maneuvers strongly depend on the patient's co-operation and health status, normal tidal breathing was investigated in an attempt to develop continuous maneuver-free measurements. APPROACH Ventilation related and pulsatile impedance changes were systematically analyzed during normal tidal breathing in 12 cystic fibrosis (CF) patients and 12 lung-healthy controls (HL). Tidal breaths were subdivided into three inspiratory (In1, In2, In3) and three expiratory (Ex1, Ex2, Ex3) sections of the same amplitude of global impedance change. Maximal changes of the ventilation and the pulsatile impedance signal occurring during these sections were determined (▵I V and ▵I P). Differences in ▵I V and ▵I P among sections were ascertained in relation to the first inspiratory section. In addition, ▵I V/▵I P was calculated for each section. MAIN RESULTS Medians of changes in ▵I V were <0.05% in all sections for both subject groups. Both groups showed a similar pattern of ▵I P changes during tidal breathing. Changes in ▵I P first decreased during inspiration (In2), then increased towards the end of inspiration (In3) and reached a maximum at the beginning of expiration (Ex1). During the last two sections of expiration (Ex2, Ex3) ▵I P changes decreased. The CF patients showed higher variations in ▵I P changes compared to the controls (CF: -426.5%, HL: -158.1%, coefficient of variation). Furthermore, ▵I V/▵I P significantly differed between expiratory sections for the CF patients (Ex1-Ex2, p < 0.01; Ex1-Ex3, p < 0.001; Ex2-Ex3, p < 0.05), but not for the controls. No significant differences in ▵I V/▵I P between inspiratory sections were determined for both groups. SIGNIFICANCE Differences in ▵I P changes and in ▵I V/▵I P between both subject groups were speculated to be caused by higher breathing efforts of the CF patients due to airway obstruction leading to higher intrathoracic pressures, and thus to greater changes in lung perfusion.
Collapse
Affiliation(s)
- Sabine Krueger-Ziolek
- Institute of Technical Medicine, Furtwangen University, Jakob-Kienzle-Straße 17, 78054 Villingen-Schwenningen, Germany. Department of Radiology, LMU University of Munich, Ziemssenstrasse 1, 80336 Munich, Germany3
| | | | | | | | | |
Collapse
|
8
|
Muller PA, Mueller JL, Mellenthin MM. Real-Time Implementation of Calderón's Method on Subject-Specific Domains. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1868-1875. [PMID: 28436855 DOI: 10.1109/tmi.2017.2695893] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
A real-time implementation of Calderón's method for the reconstruction of a 2-D conductivity from electrical impedance tomography data is presented, in which domain-specific modeling is taken into account. This is the first implementation of Calderón's method that accounts for correct modeling of non-symmetric domain boundaries in image reconstruction. The domain-specific Calderón's method is derived and reconstructions from experimental tank data are presented, quantifying the distortion when correct modeling is not included in the reconstruction algorithm. Reconstructions from human subject volunteers are presented, demonstrating the method's effectiveness for imaging changes due to ventilation and perfusion in the human thorax.
Collapse
|
9
|
Frerichs I, Amato MBP, van Kaam AH, Tingay DG, Zhao Z, Grychtol B, Bodenstein M, Gagnon H, Böhm SH, Teschner E, Stenqvist O, Mauri T, Torsani V, Camporota L, Schibler A, Wolf GK, Gommers D, Leonhardt S, Adler A. Chest electrical impedance tomography examination, data analysis, terminology, clinical use and recommendations: consensus statement of the TRanslational EIT developmeNt stuDy group. Thorax 2016; 72:83-93. [PMID: 27596161 PMCID: PMC5329047 DOI: 10.1136/thoraxjnl-2016-208357] [Citation(s) in RCA: 474] [Impact Index Per Article: 59.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2016] [Revised: 07/12/2016] [Accepted: 07/16/2016] [Indexed: 11/04/2022]
Abstract
Electrical impedance tomography (EIT) has undergone 30 years of development. Functional chest examinations with this technology are considered clinically relevant, especially for monitoring regional lung ventilation in mechanically ventilated patients and for regional pulmonary function testing in patients with chronic lung diseases. As EIT becomes an established medical technology, it requires consensus examination, nomenclature, data analysis and interpretation schemes. Such consensus is needed to compare, understand and reproduce study findings from and among different research groups, to enable large clinical trials and, ultimately, routine clinical use. Recommendations of how EIT findings can be applied to generate diagnoses and impact clinical decision-making and therapy planning are required. This consensus paper was prepared by an international working group, collaborating on the clinical promotion of EIT called TRanslational EIT developmeNt stuDy group. It addresses the stated needs by providing (1) a new classification of core processes involved in chest EIT examinations and data analysis, (2) focus on clinical applications with structured reviews and outlooks (separately for adult and neonatal/paediatric patients), (3) a structured framework to categorise and understand the relationships among analysis approaches and their clinical roles, (4) consensus, unified terminology with clinical user-friendly definitions and explanations, (5) a review of all major work in thoracic EIT and (6) recommendations for future development (193 pages of online supplements systematically linked with the chief sections of the main document). We expect this information to be useful for clinicians and researchers working with EIT, as well as for industry producers of this technology.
Collapse
Affiliation(s)
- Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Marcelo B P Amato
- Pulmonary Division, Heart Institute (InCor), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Anton H van Kaam
- Department of Neonatology, Emma Children's Hospital, Academic Medical Center, Amsterdam, The Netherlands
| | - David G Tingay
- Neonatal Research, Murdoch Childrens Research Institute, Parkville, Victoria, Australia
| | - Zhanqi Zhao
- Institute of Technical Medicine, Furtwangen University, Villingen-Schwenningen, Germany
| | - Bartłomiej Grychtol
- Fraunhofer Project Group for Automation in Medicine and Biotechnology PAMB, Mannheim, Germany
| | - Marc Bodenstein
- Department of Anesthesiology, University Medical Center of the Johannes Gutenberg-University, Mainz, Germany
| | - Hervé Gagnon
- Department of Systems and Computer Engineering, Carleton University, Ottawa, Ontario, Canada
| | | | | | - Ola Stenqvist
- Department of Anesthesiology and Intensive Care Medicine, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Tommaso Mauri
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Vinicius Torsani
- Pulmonary Division, Heart Institute (InCor), Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, São Paulo, Brazil
| | - Luigi Camporota
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, London, UK
| | - Andreas Schibler
- Paediatric Critical Care Research Group, Mater Research University of Queensland, South Brisbane, Australia
| | - Gerhard K Wolf
- Children's Hospital Traunstein, Ludwig Maximilian's University, Munich, Germany
| | - Diederik Gommers
- Department of Adult Intensive Care, Erasmus MC, Rotterdam, The Netherlands
| | - Steffen Leonhardt
- Philips Chair for Medical Information Technology, Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany
| | - Andy Adler
- Department of Systems and Computer Engineering, Carleton University, Ottawa, Ontario, Canada
| | | |
Collapse
|
10
|
Mellenthin MM, Mueller JL, Bueno de Camargo EDL, Silva de Moura F, Hamilton SJ, Gonzalez Lima R. The ACE1 thoracic Electrical Impedance Tomography system for ventilation and perfusion. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:4073-6. [PMID: 26737189 DOI: 10.1109/embc.2015.7319289] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Electrical Impedance Tomography (EIT) is a technique which can image the varying electrical properties of biological tissues. For clinical use of EIT, it can be advantageous to know both tissue conductivity and permittivity. Presented is the hardware design for the pairwise current injection active complex electrode (ACE1) EIT system which measures phasic voltages for conductivity and permittivity image reconstruction. In this system, alternating current is injected on electrodes on the boundary of a domain and single-ended voltage measurements are used in image reconstructions of the domain's interior and in calculating the current applied at the electrodes.
Collapse
|
11
|
Ericsson E, Tesselaar E, Sjöberg F. Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography. PLoS One 2016; 11:e0155913. [PMID: 27253433 PMCID: PMC4890811 DOI: 10.1371/journal.pone.0155913] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/10/2015] [Accepted: 05/08/2016] [Indexed: 11/18/2022] Open
Abstract
Ventilator-induced or ventilator-associated lung injury (VILI/VALI) is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT) can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal have not to our knowledge been thoroughly evaluated. We therefore studied ventilation-related and perfusion-related changes in impedance during spontaneous breathing in 10 healthy subjects in five different body positions and with the electrode belt placed at three different thoracic positions using a 32-electrode EIT system. We found differences between regions of interest that could be attributed to changes in the position of the body, and differences in impedance amplitudes when the position of the electrode belt was changed. Ventilation-related changes in impedance could therefore be related to changes in the position of both the body and the electrode belt. Perfusion-related changes in impedance were probably related to the interference of major vessels. While these findings give us some insight into the sources of variation in impedance signals as a result of changes in the positions of both the body and the electrode belt, further studies on the origin of the perfusion-related impedance signal are needed to improve EIT further as a tool for the monitoring of pulmonary ventilation and perfusion.
Collapse
Affiliation(s)
- Elin Ericsson
- Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
| | - Erik Tesselaar
- Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
- Department of Radiation Physics, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
- * E-mail:
| | - Folke Sjöberg
- Department of Clinical and Experimental Medicine, Linköping University, Linköping, Sweden
- Department of Hand and Plastic Surgery and the Burn Clinic, Linköping University, Linköping, Sweden
| |
Collapse
|
12
|
Sirevaag EJ, Casaccia S, Richter EA, O'Sullivan JA, Scalise L, Rohrbaugh JW. Cardiorespiratory interactions: Noncontact assessment using laser Doppler vibrometry. Psychophysiology 2016; 53:847-67. [PMID: 26970208 DOI: 10.1111/psyp.12638] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2015] [Accepted: 01/17/2016] [Indexed: 01/02/2023]
Abstract
The application of a noncontact physiological recording technique, based on the method of laser Doppler vibrometry (LDV), is described. The effectiveness of the LDV method as a physiological recording modality lies in the ability to detect very small movements of the skin, associated with internal mechanophysiological activities. The method is validated for a range of cardiovascular variables, extracted from the contour of the carotid pulse waveform as a function of phase of the respiration cycle. Data were obtained from 32 young healthy participants, while resting and breathing spontaneously. Individual beats were assigned to four segments, corresponding with inspiration and expiration peaks and transitional periods. Measures relating to cardiac and vascular dynamics are shown to agree with the pattern of effects seen in the substantial body of literature based on human and animal experiments, and with selected signals recorded simultaneously with conventional sensors. These effects include changes in heart rate, systolic time intervals, and stroke volume. There was also some evidence for vascular adjustments over the respiration cycle. The effectiveness of custom algorithmic approaches for extracting the key signal features was confirmed. The advantages of the LDV method are discussed in terms of the metrological properties and utility in psychophysiological research. Although used here within a suite of conventional sensors and electrodes, the LDV method can be used on a stand-alone, noncontact basis, with no requirement for skin preparation, and can be used in harsh environments including the MR scanner.
Collapse
Affiliation(s)
- Erik J Sirevaag
- Department of Psychiatry, Washington University School of Medicine, St. Louis, Missouri, USA
| | - Sara Casaccia
- Preston M. Green Department of Electrical and Systems Engineering, School of Engineering, Washington University in St. Louis, St. Louis, Missouri, USA.,Department of Industrial Engineering and Mathematical Science, Università Politecnica delle Marche, Ancona, Italy
| | - Edward A Richter
- Preston M. Green Department of Electrical and Systems Engineering, School of Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Joseph A O'Sullivan
- Preston M. Green Department of Electrical and Systems Engineering, School of Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Lorenzo Scalise
- Department of Industrial Engineering and Mathematical Science, Università Politecnica delle Marche, Ancona, Italy
| | - John W Rohrbaugh
- Department of Psychiatry, Washington University School of Medicine, St. Louis, Missouri, USA
| |
Collapse
|
13
|
Gong B, Krueger-Ziolek S, Moeller K, Schullcke B, Zhao Z. Electrical impedance tomography: functional lung imaging on its way to clinical practice? Expert Rev Respir Med 2015; 9:721-37. [DOI: 10.1586/17476348.2015.1103650] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
14
|
Proença M, Braun F, Rapin M, Solà J, Adler A, Grychtol B, Bohm SH, Lemay M, Thiran JP. Influence of heart motion on cardiac output estimation by means of electrical impedance tomography: a case study. Physiol Meas 2015; 36:1075-91. [PMID: 26006113 DOI: 10.1088/0967-3334/36/6/1075] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Electrical impedance tomography (EIT) is a non-invasive imaging technique that can measure cardiac-related intra-thoracic impedance changes. EIT-based cardiac output estimation relies on the assumption that the amplitude of the impedance change in the ventricular region is representative of stroke volume (SV). However, other factors such as heart motion can significantly affect this ventricular impedance change. In the present case study, a magnetic resonance imaging-based dynamic bio-impedance model fitting the morphology of a single male subject was built. Simulations were performed to evaluate the contribution of heart motion and its influence on EIT-based SV estimation. Myocardial deformation was found to be the main contributor to the ventricular impedance change (56%). However, motion-induced impedance changes showed a strong correlation (r = 0.978) with left ventricular volume. We explained this by the quasi-incompressibility of blood and myocardium. As a result, EIT achieved excellent accuracy in estimating a wide range of simulated SV values (error distribution of 0.57 ± 2.19 ml (1.02 ± 2.62%) and correlation of r = 0.996 after a two-point calibration was applied to convert impedance values to millilitres). As the model was based on one single subject, the strong correlation found between motion-induced changes and ventricular volume remains to be verified in larger datasets.
Collapse
Affiliation(s)
- Martin Proença
- Systems Division, Swiss Center for Electronics and Microtechnology (CSEM), Neuchâtel, Switzerland. Signal Processing Laboratory (LTS5), Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland
| | | | | | | | | | | | | | | | | |
Collapse
|
15
|
LI Y, TESSELAAR E, BORGES JB, BÖHM SH, SJÖBERG F, JANEROT-SJÖBERG B. Hyperoxia affects the regional pulmonary ventilation/perfusion ratio: an electrical impedance tomography study. Acta Anaesthesiol Scand 2014; 58:716-25. [PMID: 24762189 DOI: 10.1111/aas.12323] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/13/2014] [Indexed: 12/13/2022]
Abstract
BACKGROUND The way in which hyperoxia affects pulmonary ventilation and perfusion is not fully understood. We investigated how an increase in oxygen partial pressure in healthy young volunteers affects pulmonary ventilation and perfusion measured by thoracic electrical impedance tomography (EIT). METHODS Twelve semi-supine healthy male volunteers aged 21-36 years were studied while breathing room air and air-oxygen mixtures (FiO2) that resulted in predetermined transcutaneous oxygen partial pressures (tcPO2) of 20, 40 and 60 kPa. The magnitude of ventilation (ΔZv) and perfusion (ΔZQ)-related changes in cyclic impedance variations, were determined using an EIT prototype equipped with 32 electrodes around the thorax. Regional changes in ventral and dorsal right lung ventilation (V) and perfusion (Q) were estimated, and V/Q ratios calculated. RESULTS There were no significant changes in ΔZv with increasing tcPO2 levels. ΔZQ in the dorsal lung increased with increasing tcPO2 (P = 0.01), whereas no such change was seen in the ventral lung. There was a simultaneous decrease in V/Q ratio in the dorsal region during hyperoxia (P = 0.04). Two subjects did not reach a tcPO2 of 60 kPa despite breathing 100% oxygen. CONCLUSION These results indicate that breathing increased concentrations of oxygen induces pulmonary vasodilatation in the dorsal lung even at small increases in FiO2. Ventilation remains unchanged. Local mismatch of ventilation and perfusion occurs in young healthy men, and the change in ventilation/perfusion ratio can be determined non-invasively by EIT.
Collapse
Affiliation(s)
- Y. LI
- Department of Anesthesiology; Shaoxing People's Hospital of Zhejiang University; Shaoxing City China
- Department of Clinical and Experimental Medicine; Linköping University; Linköping Sweden
| | - E. TESSELAAR
- Department of Clinical and Experimental Medicine; Linköping University; Linköping Sweden
| | - J. B. BORGES
- Hedenstierna Laboratory; Department of Surgical Sciences; Section of Anesthesiology & Critical Care; Uppsala University; Uppsala Sweden
- Laboratório de Pneumologia LIM-09; Disciplina de Pneumologia; Heart Institute (Incor); Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo; São Paulo Brazil
| | | | - F. SJÖBERG
- Department of Clinical and Experimental Medicine; Linköping University; Linköping Sweden
- Department of Hand; Plastic Surgery and Intensive Care; Linköping University Hospital; Linköping Sweden
| | - B. JANEROT-SJÖBERG
- Department of Clinical Science; Intervention and Technology; Karolinska Institutet; Stockholm Sweden
- Department of Clinical Physiology; Karolinska University Hospital; Stockholm Sweden
- School of Technology and Health; KTH; Royal Institute of Technology; Stockholm Sweden
| |
Collapse
|
16
|
Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring? Intensive Care Med 2012; 38:1917-29. [DOI: 10.1007/s00134-012-2684-z] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2011] [Accepted: 08/08/2012] [Indexed: 01/08/2023]
|
17
|
Nguyen DT, Jin C, Thiagalingam A, McEwan AL. A review on electrical impedance tomography for pulmonary perfusion imaging. Physiol Meas 2012; 33:695-706. [DOI: 10.1088/0967-3334/33/5/695] [Citation(s) in RCA: 87] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
18
|
Leonhardt S, Pikkemaat R, Stenqvist O, Lundin S. Electrical Impedance Tomography for hemodynamic monitoring. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2012; 2012:122-125. [PMID: 23365847 DOI: 10.1109/embc.2012.6345886] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Electrical Impedance Tomography (EIT) is a known technique to monitor impedance changes in a cross-section of a body segment, which recently gained increasing interest for regional ventilation monitoring. In this paper, we focus on hemodynamic monitoring using EIT. Past and ongoing research activities to obtain cardiac related signals and regional perfusion information from EIT image streams are summarized. Finally, we present some preliminary results on stroke volume estimation using EIT.
Collapse
Affiliation(s)
- Steffen Leonhardt
- Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, D-52074 Aachen, Germany
| | | | | | | |
Collapse
|
19
|
Borges JB, Suarez-Sipmann F, Bohm SH, Tusman G, Melo A, Maripuu E, Sandström M, Park M, Costa ELV, Hedenstierna G, Amato M. Regional lung perfusion estimated by electrical impedance tomography in a piglet model of lung collapse. J Appl Physiol (1985) 2011; 112:225-36. [PMID: 21960654 DOI: 10.1152/japplphysiol.01090.2010] [Citation(s) in RCA: 110] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
The assessment of the regional match between alveolar ventilation and perfusion in critically ill patients requires simultaneous measurements of both parameters. Ideally, assessment of lung perfusion should be performed in real-time with an imaging technology that provides, through fast acquisition of sequential images, information about the regional dynamics or regional kinetics of an appropriate tracer. We present a novel electrical impedance tomography (EIT)-based method that quantitatively estimates regional lung perfusion based on first-pass kinetics of a bolus of hypertonic saline contrast. Pulmonary blood flow was measured in six piglets during control and unilateral or bilateral lung collapse conditions. The first-pass kinetics method showed good agreement with the estimates obtained by single-photon-emission computerized tomography (SPECT). The mean difference (SPECT minus EIT) between fractional blood flow to lung areas suffering atelectasis was -0.6%, with a SD of 2.9%. This method outperformed the estimates of lung perfusion based on impedance pulsatility. In conclusion, we describe a novel method based on EIT for estimating regional lung perfusion at the bedside. In both healthy and injured lung conditions, the distribution of pulmonary blood flow as assessed by EIT agreed well with the one obtained by SPECT. The method proposed in this study has the potential to contribute to a better understanding of the behavior of regional perfusion under different lung and therapeutic conditions.
Collapse
Affiliation(s)
- João Batista Borges
- Department of Surgical Sciences, Section of Anaesthesiology and Critical Care, Uppsala University, Uppsala, Sweden.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Grant CA, Pham T, Hough J, Riedel T, Stocker C, Schibler A. Measurement of ventilation and cardiac related impedance changes with electrical impedance tomography. CRITICAL CARE : THE OFFICIAL JOURNAL OF THE CRITICAL CARE FORUM 2011; 15:R37. [PMID: 21266025 PMCID: PMC3222074 DOI: 10.1186/cc9985] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/18/2010] [Revised: 11/03/2010] [Accepted: 01/25/2011] [Indexed: 11/10/2022]
Abstract
INTRODUCTION Electrical impedance tomography (EIT) has been shown to be able to distinguish both ventilation and perfusion. With adequate filtering the regional distributions of both ventilation and perfusion and their relationships could be analysed. Several methods of separation have been suggested previously, including breath holding, electrocardiograph (ECG) gating and frequency filtering. Many of these methods require interventions inappropriate in a clinical setting. This study therefore aims to extend a previously reported frequency filtering technique to a spontaneously breathing cohort and assess the regional distributions of ventilation and perfusion and their relationship. METHODS Ten healthy adults were measured during a breath hold and while spontaneously breathing in supine, prone, left and right lateral positions. EIT data were analysed with and without filtering at the respiratory and heart rate. Profiles of ventilation, perfusion and ventilation/perfusion related impedance change were generated and regions of ventilation and pulmonary perfusion were identified and compared. RESULTS Analysis of the filtration technique demonstrated its ability to separate the ventilation and cardiac related impedance signals without negative impact. It was, therefore, deemed suitable for use in this spontaneously breathing cohort.Regional distributions of ventilation, perfusion and the combined ΔZV/ΔZQ were calculated along the gravity axis and anatomically in each position. Along the gravity axis, gravity dependence was seen only in the lateral positions in ventilation distribution, with the dependent lung being better ventilated regardless of position. This gravity dependence was not seen in perfusion.When looking anatomically, differences were only apparent in the lateral positions. The lateral position ventilation distributions showed a difference in the left lung, with the right lung maintaining a similar distribution in both lateral positions. This is likely caused by more pronounced anatomical changes in the left lung when changing positions. CONCLUSIONS The modified filtration technique was demonstrated to be effective in separating the ventilation and perfusion signals in spontaneously breathing subjects. Gravity dependence was seen only in ventilation distribution in the left lung in lateral positions, suggesting gravity based shifts in anatomical structures. Gravity dependence was not seen in any perfusion distributions.
Collapse
Affiliation(s)
- Caroline A Grant
- Paediatric Critical Care Research Group, Paediatric Intensive Care Unit, Mater Children's Hospital, 550 Stanley Street, South Brisbane, Queensland 4101, Australia.
| | | | | | | | | | | |
Collapse
|
21
|
Carlisle HR, Armstrong RK, Davis PG, Schibler A, Frerichs I, Tingay DG. Regional distribution of blood volume within the preterm infant thorax during synchronised mechanical ventilation. Intensive Care Med 2010; 36:2101-8. [DOI: 10.1007/s00134-010-2049-4] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Accepted: 07/19/2010] [Indexed: 11/30/2022]
|
22
|
Ventilatory support for acute respiratory failure: new and ongoing pathophysiological, diagnostic and therapeutic developments. Curr Opin Crit Care 2010; 16:1-7. [PMID: 19952735 DOI: 10.1097/mcc.0b013e32833500bc] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
PURPOSE OF REVIEW Acute respiratory failure and its most severe form, the acute respiratory distress syndrome, are relatively common in the ICU setting and have a high morbidity and mortality. This article will discuss ongoing research in this area, with a focus on relatively novel approaches in terms of pathophysiology, diagnosis and therapeutic advancements. RECENT FINDINGS Several novel diagnostic and therapeutic tools, such as electrical impedance tomography, high frequency oscillatory ventilation, minimally invasive extracorporeal CO2 removal devices and neurally adjusted ventilatory assist, have recently been studied to minimize ventilator-induced lung injury. A brief review of these studies is presented in this article. SUMMARY It is increasingly evident that only integration of physiological, clinical and technological approaches will lead to improvement in the outcome of patients with acute respiratory failure.
Collapse
|
23
|
|
24
|
Fagerberg A, Stenqvist O, Aneman A. Monitoring pulmonary perfusion by electrical impedance tomography: an evaluation in a pig model. Acta Anaesthesiol Scand 2009; 53:152-8. [PMID: 19175575 DOI: 10.1111/j.1399-6576.2008.01847.x] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a non-invasive technique that generates images of impedance distribution. Changes in the pulmonary content of air and blood are major determinants of thoracic impedance. This study was designed to evaluate EIT in monitoring pulmonary perfusion in a wide range of cardiac output. METHODS Eight anaesthetised, mechanically ventilated pigs were fitted with a 16-electrode belt at the mid-thoracic level to generate EIT images that were analysed to determine pulse-synchronous systolic changes in impedance (DeltaZ(sys)). Stroke volume (SV) was derived using a pulmonary artery catheter. Reductions in cardiac pre-load, and thus pulmonary perfusion, were induced either by inflating the balloon of a Fogarty catheter positioned in the inferior caval vein or by increasing the positive end-expiratory pressure (PEEP). All measurements were performed in a steady state during a short apnoea. RESULTS Pulse-synchronous changes in DeltaZ(sys) were easily discernable during apnoea. Balloon inflation reduced SV to 36% of the baseline, with a corresponding decrease in DeltaZ(sys) to 45% of baseline. PEEP reduced SV and DeltaZ(sys) to 52% and 44% of the baseline, respectively. Significant correlations between SV and DeltaZ(sys) were demonstrated during all measurements (rho=0.62) as well as during balloon inflation (rho=0.73) and increased PEEP (rho=0.40). A Bland-Altman comparison of relative changes in SV and DeltaZ(sys) demonstrated a bias of -7%, with 95% limits of agreement at -51% and 36%. CONCLUSIONS EIT provided beat-to-beat approximations of pulmonary perfusion that significantly correlated to a wide range of SV values achieved during both extra and intrapulmonary interventions to change cardiac output.
Collapse
Affiliation(s)
- A Fagerberg
- Department of Anaesthesiology and Intensive Care, Sahlgrenska Academy, Göteborg University, Göteborg, Sweden
| | | | | |
Collapse
|
25
|
Deibele JM, Luepschen H, Leonhardt S. Dynamic separation of pulmonary and cardiac changes in electrical impedance tomography. Physiol Meas 2008; 29:S1-14. [PMID: 18544813 DOI: 10.1088/0967-3334/29/6/s01] [Citation(s) in RCA: 74] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In spontaneously breathing or ventilated subjects, it is difficult to image cardiac-related conductivity changes using electrical impedance tomography (EIT) due to the high amplitude of the ventilation component. Previous attempts to separate these components included either electrocardiogram-gated averaging, frequency domain filtering or holding the breath while performing the measurements. However, such methods are either not able to produce continuous real-time images or to fully separate cardiac and pulmonary changes. The aim of this work was to develop a new dynamic filtering method for the online separation of pulmonary and cardiac changes avoiding the drawbacks of the previous attempts. The approach is based on estimating template functions for the pulmonary and cardiac components by means of principal component analysis and frequency domain filtering. Then, these templates are fitted into the input signals. The new method enables an observer to examine the variation of the cardiac signal beat-by-beat after a one-time setup period of 20 s. Preliminary in vivo results of two healthy subjects are presented. The results are superior to frequency domain filtering and in good agreement with signals averaged over several cardiac cycles. The method does not depend on ECG or other a priori knowledge. The apparent validity of the method's ability to separate cardiac and pulmonary changes in EIT images was shown and has to be confirmed in future studies. The algorithm opens up new possibilities for future clinical trials on continuous monitoring by means of EIT and for the examination of the relation between the cardiac component and lung perfusion.
Collapse
Affiliation(s)
- J M Deibele
- Helmholtz-Institute for Biomedical Engineering, RWTH Aachen University, Aachen, Germany.
| | | | | |
Collapse
|
26
|
Electrical Impedance Tomography and its Perspectives in Intensive Care Medicine. Intensive Care Med 2007. [DOI: 10.1007/0-387-35096-9_40] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
27
|
Smit HJ, Vonk-Noordegraaf A, Boonstra A, de Vries PM, Postmus PE. Assessment of the Pulmonary Volume Pulse in Idiopathic Pulmonary Arterial Hypertension by Means of Electrical Impedance Tomography. Respiration 2006; 73:597-602. [PMID: 16205046 DOI: 10.1159/000088694] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2004] [Accepted: 05/25/2005] [Indexed: 11/19/2022] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a non-invasive imaging technique which can be used to measure the blood volume changes in the pulmonary vascular bed during the cardiac cycle. STUDY OBJECTIVES This study was performed to evaluate the differences in the EIT signal of the pulmonary vascular bed between healthy subjects and patients with idiopathic pulmonary arterial hypertension (IPAH), who are known to have a remodelled pulmonary vascular bed. PATIENTS AND METHODS Twenty-one patients (17 females, 4 males) with IPAH and 30 healthy controls (5 females, 25 males) were measured. EIT measurements were performed in duplicate, on the same day as right heart catheterization to obtain haemodynamic data. The maximal impedance change during systole (Delta Z(sys)) was used as a measure of the pulmonary volume pulse and expressed in arbitrary units (AU). Total lung capacity, spirometric values and diffusion capacity for carbon monoxide were measured as well. RESULTS Mean Delta Z(sys) was 215 +/- 58 x 10(-2) AU (95% CI 193 x 10(-2) to 236 x 10(-2)) in the healthy subjects and 78 +/- 27 x 10(-2) AU (95% CI 66 x 10(-2) to 91 x 10(-2)) in the IPAH patient group (p < 0.0001). No significant correlation was found between Delta Z(sys) and any of the haemodynamic or lung function data. CONCLUSION The impedance pulsation of the pulmonary vascular bed is reduced in IPAH in comparison with controls, indicating a reduced volume pulse. This might represent the reduced cross section area, as well as the reduced compliance and number of the pulmonary vessels in these patients.
Collapse
Affiliation(s)
- Henk J Smit
- Department of Pulmonary Diseases, VU Medical Center, Amsterdam, The Netherlands.
| | | | | | | | | |
Collapse
|
28
|
Isaacson D, Mueller JL, Newell JC, Siltanen S. Imaging cardiac activity by the D-bar method for electrical impedance tomography. Physiol Meas 2006; 27:S43-50. [PMID: 16636419 PMCID: PMC1752230 DOI: 10.1088/0967-3334/27/5/s04] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
A practical D-bar algorithm for reconstructing conductivity changes from EIT data taken on electrodes in a 2D geometry is described. The algorithm is based on the global uniqueness proof of Nachman (1996 Ann. Math. 143 71-96) for the 2D inverse conductivity problem. Results are shown for reconstructions from data collected on electrodes placed around the circumference of a human chest to reconstruct a 2D cross-section of the torso. The images show changes in conductivity during a cardiac cycle.
Collapse
Affiliation(s)
- D Isaacson
- Department of Mathematical Sciences, Rensselaer Polytechnic Institute, Troy, NY 12180, USA
| | | | | | | |
Collapse
|
29
|
Frerichs I, Scholz J, Weiler N. Electrical Impedance Tomography and its Perspectives in Intensive Care Medicine. YEARBOOK OF INTENSIVE CARE AND EMERGENCY MEDICINE 2006. [DOI: 10.1007/3-540-33396-7_40] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
30
|
Smit HJ, Vonk Noordegraaf A, Marcus JT, Boonstra A, de Vries PM, Postmus PE. Determinants of pulmonary perfusion measured by electrical impedance tomography. Eur J Appl Physiol 2004; 92:45-9. [PMID: 14985995 DOI: 10.1007/s00421-004-1043-3] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/15/2003] [Indexed: 10/26/2022]
Abstract
Electrical impedance tomography (EIT) is a non-invasive imaging technique for detecting blood volume changes that can visualize pulmonary perfusion. The two studies reported here tested the hypothesis that the size of the pulmonary microvascular bed, rather than stroke volume (SV), determines the EIT signal. In the first study, the impedance changes relating to the maximal pulmonary pulsatile blood volume during systole (Delta Z(sys)) were measured in ten healthy subjects, ten patients diagnosed with chronic obstructive pulmonary disease, who were considered to have a reduced pulmonary vascular bed, and ten heart failure patients with an assumed low cardiac output but with a normal lung parenchyma. Mean Delta Z(sys) (SD) in these groups was 261 (34)x10(-5), 196 (39)x10(-5) ( P<0.001) and 233 (61)x10(-5) arbitrary units (AU) (P=NS), respectively. In the second study, including seven healthy volunteers, Delta Z(sys) was measured at rest and during exercise on a recumbent bicycle while SV was measured by means of magnetic resonance imaging. The Delta Z(sys) at rest was 352 (53)x10(-5 ) and 345 (112)x10(-5 )AU during exercise (P=NS), whereas SV increased from 83 (21) to 105 (34) ml (P<0.05). The EIT signal likely reflects the size of the pulmonary microvascular bed, since neither a low cardiac output nor a change in SV of the heart appear to influence EIT.
Collapse
Affiliation(s)
- Henk J Smit
- Department of Pulmonary Medicine, VU Medical Center, PO Box 7057, 1007 MB Amsterdam, The Netherlands
| | | | | | | | | | | |
Collapse
|
31
|
Smit HJ, Vonk-Noordegraaf A, Marcus JT, van der Weijden S, Postmus PE, de Vries PMJM, Boonstra A. Pulmonary vascular responses to hypoxia and hyperoxia in healthy volunteers and COPD patients measured by electrical impedance tomography. Chest 2003; 123:1803-9. [PMID: 12796153 DOI: 10.1378/chest.123.6.1803] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a noninvasive imaging technique using impedance to visualize and measure blood volume changes. STUDY OBJECTIVE To examine the validity of EIT in the measurement of hypoxic pulmonary vasoconstriction (HPV) and hyperoxic pulmonary vasodilation in healthy volunteers and COPD patients. PARTICIPANTS Group 1 consisted of seven healthy volunteers (mean age, 46 years; age range, 36 to 53 years). Group 2 comprised six clinically stable COPD patients (mean age, 65 years; age range, 50 to 74 years). INTERVENTIONS EIT measurements were performed in healthy subjects while they were breathing room air, 14% oxygen (ie, hypoxia), and 100% oxygen (ie, hyperoxia) through a mouthpiece. Maximal impedance change during systole (DeltaZsys) was used as a measure of pulmonary perfusion-related impedance changes. Stroke volume (SV) was measured by means of MRI. In the COPD group, EIT and SV also were determined, but only in room air and under hyperoxic conditions. RESULTS The data were statistically compared to data for the room air baseline condition. In the volunteers, the mean (+/- SD) DeltaZsys for the group was 352 +/- 53 arbitrary units (AU) while breathing room air, 309 +/- 75 AU in hypoxia (p < 0.05), and 341 +/- 69 AU in hyperoxia (not significant [NS]). The mean MRI-measured SV was 83 +/- 21 mL while breathing room air, 90 +/- 29) mL in hypoxia (NS), and 94 +/- 19 mL in hyperoxia (p < 0.05). In the COPD patients, the mean DeltaZsys for this group was 222 +/- 84 AU while breathing room air and 255 +/- 83 AU in hyperoxia (p < 0.05). In this group, the SV was 59 +/- 16 mL while breathing room air and 61 +/- 13 mL in hyperoxia (NS). Thus, the volunteer EIT response to hypoxia is not caused by decreased SV, because SV did not show a significant decrease. Similarly, in COPD patients the EIT response to hyperoxia is not caused by increased SV, because SV showed only a minor change. CONCLUSION EIT can detect blood volume changes due to HPV noninvasively in healthy subjects and hyperoxic vasodilation in COPD patients.
Collapse
Affiliation(s)
- Henk J Smit
- Department of Pulmonary Medicine, Vrije Universiteit Medical Center, Amsterdam, the Netherlands.
| | | | | | | | | | | | | |
Collapse
|
32
|
Smit HJ, Handoko ML, Vonk Noordegraaf A, Faes TJC, Postmus PE, de Vries PMJM, Boonstra A. Electrical impedance tomography to measure pulmonary perfusion: is the reproducibility high enough for clinical practice? Physiol Meas 2003; 24:491-9. [PMID: 12812432 DOI: 10.1088/0967-3334/24/2/359] [Citation(s) in RCA: 38] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A possible clinical application of electrical impedance tomography (EIT) might be to monitor changes in the pulmonary circulation, provided the reproducibility of the EIT measurement is adequate. The purpose of this study was threefold: the intra- and inter-investigator variability of repeated measurements was investigated. Three different regions of interest (ROI) were analysed to assess the optimal ROI. Twenty-four healthy subjects and six patients were included. The Sheffield applied potential tomograph (DAS-01P, IBEES, Sheffield, UK) was used. Electrodes were attached by investigator A, and duplicate EIT measurements were performed. After detachment and 45 min of rest, the protocol was repeated by another investigator B, and afterwards by the initial investigator A. Three ROIs were analysed: whole circle, 'inner half circle' and contour. The mean difference in impedance changes between observers is presented in arbitrary units (AU) +/- SD. Finally, the influence of age, body composition and sex on the EIT result was examined. For the contour ROI, the mean difference for the intra-investigator situation was -1.44 x 10(-2) +/- 18.45 x 10(-2) AU (-0.7 +/- 9.0%), and was 5.46 x 10(-2) +/- 21.66 x 10(-2) AU (2.7 +/- 10.8%) for the inter-investigator situation. The coefficient of reproducibility of the intra- and inter-investigator reproducibility varied between 0.89 and 0.97 for all ROIs (P < 0.0001). There is a relation between impedance change and age (correlation coefficient r = -0.63, P < 0.01 for contour ROI), and between impedance change and body mass index (BMI) (r = -0.53, P < 0.05). We found a significant difference in mean impedance change between groups of males and females. In conclusion, EIT results are highly reproducible when performed by the same investigator as well as by two different investigators.
Collapse
Affiliation(s)
- H J Smit
- Department of Pulmonary Medicine, VU University Medical Center, Amsterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
33
|
Frerichs I, Hinz J, Herrmann P, Weisser G, Hahn G, Quintel M, Hellige G. Regional lung perfusion as determined by electrical impedance tomography in comparison with electron beam CT imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2002; 21:646-652. [PMID: 12166861 PMCID: PMC7186030 DOI: 10.1109/tmi.2002.800585] [Citation(s) in RCA: 116] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/21/2001] [Revised: 02/14/2002] [Indexed: 05/23/2023]
Abstract
The aim of the experiments was to check the feasibility of pulmonary perfusion imaging by functional electrical impedance tomography (EIT) and to compare the EIT findings with electron beam computed tomography (EBCT) scans. In three pigs, a Swan-Ganz catheter was positioned in a pulmonary artery branch and hypertonic saline solution or a radiographic contrast agent were administered as boli through the distal or proximal openings of the catheter. During the administration through the proximal opening, the balloon at the tip of the catheter was either deflated or inflated. The latter case represented a perfusion defect. The series of EIT scans of the momentary distribution of electrical impedance within the chest were obtained during each saline bolus administration at a rate of 13/s. EBCT scans were acquired at a rate of 3.3/s during bolus administrations of the radiopaque contrast material under the same steady-state conditions. The EIT data were used to generate local time-impedance curves and functional EIT images showing the perfusion of a small lung region, both lungs with a perfusion defect and complete both lungs during bolus administration through the distal and proximal catheter opening with an inflated or deflated balloon, respectively. The results indicate that EIT imaging of lung perfusion is feasible when an electrical impedance contrast agent is used.
Collapse
Affiliation(s)
- Inéz Frerichs
- Department of Anesthesiological Research, Center of Anesthesiology, Emergency and Intensive Care Medicine, University of Göttingen, Germany.
| | | | | | | | | | | | | |
Collapse
|
34
|
Smit HJ, Vonk Noordegraaf A, Roeleveld RJ, Bronzwaer JGF, Postmus PE, de Vries PMJM, Boonstra A. Epoprostenol-induced pulmonary vasodilatation in patients with pulmonary hypertension measured by electrical impedance tomography. Physiol Meas 2002; 23:237-43. [PMID: 11878269 DOI: 10.1088/0967-3334/23/1/324] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Electrical impedance tomography (EIT) has been proposed as a method to monitor dynamic changes in the pulmonary vascular bed. In this study we examined the validity of EIT in the measurement of pulmonary vasodilatation in eight patients with primary and secondary pulmonary hypertension when given the vasodilating agent epoprostenol (Flolan). Therefore, catheterization of the pulmonary artery was performed in the ICU and the cardiac output was measured by means of the Fick method. The pulmonary vascular resistance (PVR) and mean pulmonary arterial pressure (mPAP) were determined. Epoprostenol was given in increasing doses to test reversibility of pulmonary hypertension. The maximum test dose was 12 ng kg(-1) min(-1). During each step simultaneous EIT (DAS-01 P Portable Data Acquisition System, Sheffield, England) measurements were performed with the 16 electrodes equidistantly positioned in the third intercostal space. The maximal systolic impedance change, relative to end-diastole, deltaZperf, was chosen as a measure of pulmonary perfusion. The impedance change between baseline and highest tolerable epoprostenol concentration was compared with the change in PVR. The mean PVR (dyn s/cm5) decreased from 636 (+/-399) to 366 (+/-242); p < 0.01. DeltaZperf (in arbitrary units) for the whole patient group increased from 901 (+/-295) x 10(-3) to 1082 (+/-472) x 10(-3) (p<0.05). Only one patient showed a reduction in pulmonary artery pressure >20%, which is defined as significant vasodilatation. A strong relationship was found between the impedance changes and the change in PVR and mPAP in the patient with a significant vasodilatation on epoprostenol. From these results we conclude that EIT is a reliable method to measure blood volume changes due to pharmacologically induced vasodilatation in the pulmonary bed.
Collapse
Affiliation(s)
- H J Smit
- Department of Pulmonary Medicine, Vrije Universiteit Medical Center, Amsterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|
35
|
Vonk-Noordegraaf A, Janse A, Marcus JT, Bronzwaer JG, Postmust PE, Faes TJ, De Vries PM. Determination of stroke volume by means of electrical impedance tomography. Physiol Meas 2000; 21:285-93. [PMID: 10847195 DOI: 10.1088/0967-3334/21/2/308] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
ECG-gated electrical impedance tomography (EIT) is a non-invasive imaging technique, developed to monitor blood volume changes. This study is the first in comparing this non-invasive technique in measuring stroke volume with established techniques. The objective of this study was to validate EIT variables derived from the EIT images with paired obtained stroke volume measurements by thermodilution and MRI. After right cardiac catheterization, EIT measurements were performed in 25 patients. Regression analysis was used to analyse the relation between the EIT results and stroke volume determined by thermodilution. From the regression line an equation was derived to estimate stroke volume (in ml) by EIT. A strong correlation was found between EIT and stroke volume measured by the thermodilution method (r = 0.86). In a group of 11 healthy subjects this equation was validated to MRI. The mean and standard deviation of the difference between EIT and MRI was 0.7 ml and 5.4 ml respectively. These data indicate that EIT is a valid and reproducible method for the assessment of stroke volume.
Collapse
Affiliation(s)
- A Vonk-Noordegraaf
- Department of Pulmonary Medicine, Institute for Cardiovascular Research, Academic Hospital Vrije Universiteit, Amsterdam, The Netherlands.
| | | | | | | | | | | | | |
Collapse
|