Heines SJH, Becher TH, van der Horst ICC, Bergmans DCJJ. Clinical Applicability of Electrical Impedance Tomography in Patient-Tailored Ventilation: A Narrative Review. Tomography 2023; 9:1903-1932. [PMID: 37888742 PMCID: PMC10611090 DOI: 10.3390/tomography9050150] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2023] [Revised: 10/05/2023] [Accepted: 10/16/2023] [Indexed: 10/28/2023] Open
Abstract
Electrical Impedance Tomography (EIT) is a non-invasive bedside imaging technique that provides real-time lung ventilation information on critically ill patients. EIT can potentially become a valuable tool for optimising mechanical ventilation, especially in patients with acute respiratory distress syndrome (ARDS). In addition, EIT has been shown to improve the understanding of ventilation distribution and lung aeration, which can help tailor ventilatory strategies according to patient needs. Evidence from critically ill patients shows that EIT can reduce the duration of mechanical ventilation and prevent lung injury due to overdistension or collapse. EIT can also identify the presence of lung collapse or recruitment during a recruitment manoeuvre, which may guide further therapy. Despite its potential benefits, EIT has not yet been widely used in clinical practice. This may, in part, be due to the challenges associated with its implementation, including the need for specialised equipment and trained personnel and further validation of its usefulness in clinical settings. Nevertheless, ongoing research focuses on improving mechanical ventilation and clinical outcomes in critically ill patients.
Collapse
Affiliation(s)
- Serge J. H. Heines
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
| | - Tobias H. Becher
- Department of Anesthesiology and Intensive Care Medicine, Campus Kiel, University Medical Centre Schleswig-Holstein, 24118 Kiel, Germany;
| | - Iwan C. C. van der Horst
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, 6229 HX Maastricht, The Netherlands
| | - Dennis C. J. J. Bergmans
- Department of Intensive Care Medicine, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands; (I.C.C.v.d.H.); (D.C.J.J.B.)
- School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, 6229 ER Maastricht, The Netherlands
| |
Collapse
|
2
|
Effects of pleural effusion drainage in the mechanically ventilated patient as monitored by electrical impedance tomography and end-expiratory lung volume: A pilot study. J Crit Care 2020; 59:76-80. [DOI: 10.1016/j.jcrc.2020.06.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 04/25/2020] [Accepted: 06/01/2020] [Indexed: 12/17/2022]
|
3
|
Spinelli E, Mauri T, Fogagnolo A, Scaramuzzo G, Rundo A, Grieco DL, Grasselli G, Volta CA, Spadaro S. Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions. BMC Anesthesiol 2019; 19:140. [PMID: 31390977 PMCID: PMC6686519 DOI: 10.1186/s12871-019-0814-7] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2019] [Accepted: 07/29/2019] [Indexed: 01/26/2023] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is a non-invasive radiation-free monitoring technique that provides images based on tissue electrical conductivity of the chest. Several investigations applied EIT in the context of perioperative medicine, which is not confined to the intraoperative period but begins with the preoperative assessment and extends to postoperative follow-up. MAIN BODY EIT could provide careful respiratory monitoring in the preoperative assessment to improve preparation for surgery, during anaesthesia to guide optimal ventilation strategies and to monitor the hemodynamic status and in the postoperative period for early detection of respiratory complications. Moreover, EIT could further enhance care of patients undergoing perioperative diagnostic procedures. This narrative review summarizes the latest evidence on the application of this technique to the surgical patient, focusing also on possible future perspectives. CONCLUSIONS EIT is a promising technique for the perioperative assessment of surgical patients, providing tailored adaptive respiratory and haemodynamic monitoring. Further studies are needed to address the current technological limitations, confirm the findings and evaluate which patients can benefit more from this technology.
Collapse
Affiliation(s)
- Elena Spinelli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Tommaso Mauri
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Alberto Fogagnolo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Gaetano Scaramuzzo
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Annalisa Rundo
- UOC Anestesia e Rianimazione, Polo ospedaliero Belcolle ASL, Viterbo, Italy
| | - Domenico Luca Grieco
- Department of Anesthesiology and Intensive Care Medicine, Catholic University of the Sacred Heart, Fondazione "Policlinico Universitario A. Gemelli", Rome, Italy
| | - Giacomo Grasselli
- Dipartimento di Anestesia, Rianimazione ed Emergenza-Urgenza, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Università degli studi di Milano, Milan, Italy
| | - Carlo Alberto Volta
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy
| | - Savino Spadaro
- Department Morphology, Surgery and Experimental medicine, Anesthesia and Intensive care section, University of Ferrara, Azienda Ospedaliera- Universitaria Sant'Anna, 8, Aldo Moro, Ferrara, Italy.
| |
Collapse
|
4
|
Frerichs I, Dargaville PA, Rimensberger PC. Regional pulmonary effects of bronchoalveolar lavage procedure determined by electrical impedance tomography. Intensive Care Med Exp 2019; 7:11. [PMID: 30771111 PMCID: PMC6377686 DOI: 10.1186/s40635-019-0225-6] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Accepted: 02/06/2019] [Indexed: 12/13/2022] Open
Abstract
Background The provision of guidance in ventilator therapy by continuous monitoring of regional lung ventilation, aeration and respiratory system mechanics is the main clinical benefit of electrical impedance tomography (EIT). A new application was recently described in critically ill patients undergoing diagnostic bronchoalveolar lavage (BAL) with the intention of using EIT to identify the region where sampling was performed. Increased electrical bioimpedance was reported after fluid instillation. To verify the accuracy of these findings, contradicting the current EIT knowledge, we have systematically analysed chest EIT data acquired under controlled experimental conditions in animals undergoing a large number of BAL procedures. Methods One hundred thirteen BAL procedures were performed in 13 newborn piglets positioned both supine and prone. EIT data was obtained at 13 images before, during and after each BAL. The data was analysed at three time points: (1) after disconnection from the ventilator before the fluid instillation and by the ends of fluid (2) instillation and (3) recovery by suction and compared with the baseline measurements before the procedure. Functional EIT images were generated, and changes in pixel electrical bioimpedance were calculated relative to baseline. The data was examined in the whole image and in three (ventral, middle, dorsal) regions-of-interest per lung. Results Compared with the baseline phase, chest electrical bioimpedance fell after the disconnection from the ventilator in all animals in both postures during all procedures. The fluid instillation further decreased electrical bioimpedance. During fluid recovery, electrical bioimpedance increased, but not to baseline values. All effects were highly significant (p < 0.001). The fractional changes in individual regions-of-interest were posture-dependent. The regional fall in electrical bioimpedance was smaller in the ventral and larger in the dorsal regions after the fluid instillation than after the initial disconnection to ambient pressure in supine animals (p < 0.001) whereas these changes were of comparable amplitude in prone position. Conclusions The results of this study show a regionally dissimilar initial fall in electrical bioimpedance caused by non-uniform aeration loss at the beginning of the BAL procedure. They also confirm a further pronounced fall in bioimpedance during fluid instillation, incomplete recovery after suction and a posture-dependent distribution pattern of these effects. Electronic supplementary material The online version of this article (10.1186/s40635-019-0225-6) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Inéz Frerichs
- Department of Anaesthesiology and Intensive Care Medicine, University Medical Centre Schleswig-Holstein, Campus Kiel, Arnold-Heller-Str. 3, 24105, Kiel, Germany.
| | - Peter A Dargaville
- Neonatal and Paediatric Intensive Care Unit, Royal Hobart Hospital, Hobart, Australia.,Menzies Institute for Medical Research, University of Tasmania, Hobart, Australia
| | - Peter C Rimensberger
- Pediatric and Neonatal Intensive Care Unit, Children's Hospital, University of Geneva, Geneva, Switzerland
| |
Collapse
|
5
|
Characteristic pattern of pleural effusion in electrical impedance tomography images of critically ill patients. Br J Anaesth 2018; 120:1219-1228. [PMID: 29793589 DOI: 10.1016/j.bja.2018.02.030] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 02/19/2018] [Accepted: 03/01/2018] [Indexed: 12/16/2022] Open
Abstract
BACKGROUND Electrical impedance tomography (EIT) is increasingly used for continuous monitoring of ventilation in intensive care patients. Clinical observations in patients with pleural effusion show an increase in out-of-phase impedance changes. We hypothesised that out-of-phase impedance changes are a typical EIT finding in patients with pleural effusion and could be useful in its detection. METHODS We conducted a prospective observational study in intensive care unit patients with and without pleural effusion. In patients with pleural effusion, EIT data were recorded before, during, and after unilateral drainage of pleural effusion. In patients with no pleural effusion, EIT data were recorded without any intervention. EIT images were separated into four quadrants of equal size. We analysed the sum of out-of-phase impedance changes in the affected quadrant in patients with pleural effusion before, during, and after drainage and compared it with the sum of out-of-phase impedance changes in the dorsal quadrants of patients without pleural effusion. RESULTS We included 20 patients with pleural effusion and 10 patients without pleural effusion. The median sum of out-of-phase impedance changes was 70 (interquartile range 49-119) arbitrary units (a.u.) in patients with pleural effusion before drainage, 25 (12-46) a.u. after drainage (P<0.0001) and 11 (6-17) a.u. in patients without pleural effusion (P<0.0001 vs pleural effusion before drainage). The area under the receiver operating characteristics curve was 0.96 (95% limits of agreement 0.91-1.01) between patients with pleural effusion before drainage and those without pleural effusion. CONCLUSIONS In patients monitored with EIT, the presence of out-of-phase impedance changes is highly suspicious of pleural effusion and should trigger further examination.
Collapse
|
6
|
Vogt B, Zhao Z, Zabel P, Weiler N, Frerichs I. Regional lung response to bronchodilator reversibility testing determined by electrical impedance tomography in chronic obstructive pulmonary disease. Am J Physiol Lung Cell Mol Physiol 2016; 311:L8-L19. [DOI: 10.1152/ajplung.00463.2015] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/04/2016] [Accepted: 05/17/2016] [Indexed: 01/01/2023] Open
Abstract
Patients with obstructive lung diseases commonly undergo bronchodilator reversibility testing during examination of their pulmonary function by spirometry. A positive response is defined by an increase in forced expiratory volume in 1 s (FEV1). FEV1 is a rather nonspecific criterion not allowing the regional effects of bronchodilator to be assessed. We employed the imaging technique of electrical impedance tomography (EIT) to visualize the spatial and temporal ventilation distribution in 35 patients with chronic obstructive pulmonary disease at baseline and 5, 10, and 20 min after bronchodilator inhalation. EIT scanning was performed during tidal breathing and forced full expiration maneuver in parallel with spirometry. Ventilation distribution was determined by EIT by calculating the image pixel values of FEV1, forced vital capacity (FVC), tidal volume, peak flow, and mean forced expiratory flow between 25 and 75% of FVC. The global inhomogeneity indexes of each measure and histograms of pixel FEV1/FVC values were then determined to assess the bronchodilator effect on spatial ventilation distribution. Temporal ventilation distribution was analyzed from pixel values of times needed to exhale 75 and 90% of pixel FVC. Based on spirometric FEV1, significant bronchodilator response was found in 17 patients. These patients exhibited higher postbronchodilator values of all regional EIT-derived lung function measures in contrast to nonresponders. Ventilation distribution was inhomogeneous in both groups. Significant improvements were noted for spatial distribution of pixel FEV1 and tidal volume and temporal distribution in responders. By providing regional data, EIT might increase the diagnostic and prognostic information derived from reversibility testing.
Collapse
Affiliation(s)
- Barbara Vogt
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Zhanqi Zhao
- Department of Biomedical Engineering, Furtwangen University, Villingen-Schwenningen, Germany; and
| | - Peter Zabel
- Department of Pneumology, Medical Clinic, Research Center Borstel, Germany
| | - Norbert Weiler
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| | - Inéz Frerichs
- Department of Anesthesiology and Intensive Care Medicine, University Medical Center Schleswig-Holstein, Campus Kiel, Kiel, Germany
| |
Collapse
|
7
|
Gong B, Krueger-Ziolek S, Moeller K, Schullcke B, Zhao Z. Electrical impedance tomography: functional lung imaging on its way to clinical practice? Expert Rev Respir Med 2015; 9:721-37. [DOI: 10.1586/17476348.2015.1103650] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
8
|
Roth CJ, Ehrl A, Becher T, Frerichs I, Schittny JC, Weiler N, Wall WA. Correlation between alveolar ventilation and electrical properties of lung parenchyma. Physiol Meas 2015; 36:1211-26. [DOI: 10.1088/0967-3334/36/6/1211] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
9
|
Nebuya S, Koike T, Imai H, Iwashita Y, Brown BH, Soma K. Feasibility of using ‘lung density’ values estimated from EIT images for clinical diagnosis of lung abnormalities in mechanically ventilated ICU patients. Physiol Meas 2015; 36:1261-71. [DOI: 10.1088/0967-3334/36/6/1261] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|