1
|
Szabo S, Totka Z, Nagy-Bozsoky J, Pinter I, Bagany M, Bodo M. Rheoencephalography: A non-invasive method for neuromonitoring. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2024; 15:10-25. [PMID: 38482467 PMCID: PMC10936697 DOI: 10.2478/joeb-2024-0003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/07/2023] [Indexed: 04/07/2024]
Abstract
In neurocritical care, the gold standard method is intracranial pressure (ICP) monitoring for the patient's lifesaving. Since it is an invasive method, it is desirable to use an alternative, noninvasive technique. The computerized real-time invasive cerebral blood flow (CBF) autoregulation (AR) monitoring calculates the status of CBF AR, called the pressure reactivity index (PRx). Studies documented that the electrical impedance of the head (Rheoencephalography - REG) can detect the status of CBF AR (REGx) and ICP noninvasively. We aimed to test REG to reflect ICP and CBF AR. For nineteen healthy subjects we recorded bipolar bifrontal and bitemporal REG derivations and arm bioimpedance pulses with a 200 Hz sampling rate. The challenges were a 30-second breath-holding and head-down-tilt (HDT - Trendelenburg) position. Data were stored and processed offline. REG pulse wave morphology and REGx were calculated. The most relevant finding was the significant morphological change of the REG pulse waveform (2nd peak increase) during the HDT position. Breath-holding caused REG amplitude increase, but it was not significant. REGx in male and female group averages have similar trends during HDT by indicating the active status of CBF AR. The morphological change of REG pulse wave during HDT position was identical to ICP waveform change during increased ICP, reflecting decreased intracranial compliance. A correlation study between ICP and REG was initiated in neurocritical care patients. The noninvasive REG monitoring would also be useful in space research as well as in military medicine during the transport of wounded service members as well as for fighter pilots to indicate the loss of CBF and consciousness.
Collapse
Affiliation(s)
- Sandor Szabo
- University of Szeged, Faculty of General Medicine, Department of Aviation and Space Medicine. Kecskemet, Hungary; Hungarian Defence Forces Medical Center, Aeromedical, Military Medical Screening and Healthcare Instituter;Kecskemet, Hungary
| | - Zsolt Totka
- University of Szeged, Faculty of General Medicine, Department of Aviation and Space Medicine. Kecskemet, Hungary; Hungarian Defence Forces Medical Center, Aeromedical, Military Medical Screening and Healthcare Instituter;Kecskemet, Hungary
| | - Jozsef Nagy-Bozsoky
- University of Szeged, Faculty of General Medicine, Department of Aviation and Space Medicine. Kecskemet, Hungary; Hungarian Defence Forces Medical Center, Aeromedical, Military Medical Screening and Healthcare Instituter;Kecskemet, Hungary
| | | | | | - Michael Bodo
- Uniformed Services University of the Health Sciences, Bethesda, MD, USA
| |
Collapse
|
2
|
Cannizzaro LA, Iwuchukwu I, Rahaman V, Hirzallah M, Bodo M. Noninvasive neuromonitoring with rheoencephalography: a case report. J Clin Monit Comput 2023; 37:1413-1422. [PMID: 36934402 PMCID: PMC10024795 DOI: 10.1007/s10877-023-00985-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Accepted: 02/16/2023] [Indexed: 03/20/2023]
Abstract
Cerebral blood flow (CBF) autoregulation (AR) can be monitored using invasive modalities, such as intracranial pressure (ICP) and arterial blood pressure (ABP) to calculate the CBF AR index (PRx). Monitoring PRx can reduce the extent of secondary brain damage in patients. Rheoencephalography (REG) is an FDA-approved non-invasive method to measure CBF. REGx, a CBF AR index, is calculated from REG and arm bioimpedance pulse waves. Our goal was to test REG for neuromonitoring. 28 measurement sessions were performed on 13 neurocritical care patients. REG/arm bioimpedance waveforms were recorded on a laptop using a bioimpedance amplifier and custom-built software. The same program was used for offline data processing. Case #1: The patient's mean REGx increased from - 0.08 on the first day to 0.44 on the second day, indicating worsening intracranial compliance (ICC) (P < 0.0001, CI 0.46-0.58). Glasgow Coma Scale (GCS) was 5 on both days. Case #2: REGx decreased from 0.32 on the first recording to 0.07 on the last (P = 0.0003, CI - 0.38 to - 0.12). GCS was 7 and 14, respectively. Case #3: Within a 36-minute recording, REGx decreased from 0.56 to - 0.37 (P < 0.0001, 95%, CI - 1.10 to - 0.76). Central venous pressure changed from 14 to 9 mmHg. REG pulse wave morphology changed from poor ICC to good ICC morphology. Bioimpedance recording made it possible to quantify the active/passive status of CBF AR, indicate the worsening of ICC, and present it in real time. REGx can be a suitable, non-invasive alternative to PRx for use in head-injured patients.
Collapse
Affiliation(s)
| | | | | | | | - Michael Bodo
- 1Ochsner Medical Center, New Orleans, LA, USA.
- Uniformed Services University of the Health Sciences, Bethesda, MD, USA.
| |
Collapse
|
3
|
He C, Teng C, Xiong Z, Lin X, Li H, Li X. Intracranial pressure monitoring in neurosurgery: the present situation and prospects. Chin Neurosurg J 2023; 9:14. [PMID: 37170383 PMCID: PMC10176793 DOI: 10.1186/s41016-023-00327-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 04/24/2023] [Indexed: 05/13/2023] Open
Abstract
Intracranial pressure (ICP) is one of the most important indexes in neurosurgery. It is essential for doctors to determine the numeric value and changes of ICP, whether before or after an operation. Although external ventricular drainage (EVD) is the gold standard for monitoring ICP, more and more novel monitoring methods are being applied clinically.Invasive wired ICP monitoring is still the most commonly used in practice. Meanwhile, with the rise and development of various novel technologies, non-invasive types and invasive wireless types are gradually being used clinically or in the testing phase, as a complimentary approach of ICP management. By choosing appropriate monitoring methods, clinical neurosurgeons are able to obtain ICP values safely and effectively under particular conditions.This article introduces diverse monitoring methods and compares the advantages and disadvantages of different monitoring methods. Moreover, this review may enable clinical neurosurgeons to have a broader view of ICP monitoring.
Collapse
Affiliation(s)
- Chenqi He
- Department of Neurosurgery, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
- Hunan International Scientific and Technological Cooperation Base of Brain Tumor Research, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
| | - Chubei Teng
- Department of Neurosurgery, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
- Hunan International Scientific and Technological Cooperation Base of Brain Tumor Research, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
- Department of Neurosurgery, the First Affiliated Hospital, University of South China, Hengyang, Hunan, 421001, People's Republic of China
| | - Zujian Xiong
- Department of Neurosurgery, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
- Hunan International Scientific and Technological Cooperation Base of Brain Tumor Research, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
| | - Xuelei Lin
- Department of Neurosurgery, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
- Hunan International Scientific and Technological Cooperation Base of Brain Tumor Research, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
| | - Hongbo Li
- Department of Neurosurgery, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
- Hunan International Scientific and Technological Cooperation Base of Brain Tumor Research, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China
| | - Xuejun Li
- Department of Neurosurgery, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China.
- Hunan International Scientific and Technological Cooperation Base of Brain Tumor Research, Xiangya Hospital, Central South University, Changsha, Hunan, 410008, People's Republic of China.
| |
Collapse
|
4
|
Montgomery LD, Montgomery RW, Bodo M, Mahon RT, Pearce FJ. Thoracic, Peripheral, and Cerebral Volume, Circulatory and Pressure Responses To PEEP During Simulated Hemorrhage in a Pig Model: a Case Study. JOURNAL OF ELECTRICAL BIOIMPEDANCE 2021; 12:103-116. [PMID: 35069946 PMCID: PMC8713386 DOI: 10.2478/joeb-2021-0013] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Indexed: 06/14/2023]
Abstract
Positive end-expiratory pressure (PEEP) is a respiratory/ventilation procedure that is used to maintain or improve breathing in clinical and experimental cases that exhibit impaired lung function. Body fluid shift movement is not monitored during PEEP application in intensive care units (ICU), which would be interesting specifically in hypotensive patients. Brain injured and hypotensive patients are known to have compromised cerebral blood flow (CBF) autoregulation (AR) but currently, there is no non-invasive way to assess the risk of implementing a hypotensive resuscitation strategy and PEEP use in these patients. The advantage of electrical bioimpedance measurement is that it is noninvasive, continuous, and convenient. Since it has good time resolution, it is ideal for monitoring in intensive care units (ICU). The basis of its future use is to establish physiological correlates. In this study, we demonstrate the use of electrical bioimpedance measurement during bleeding and the use of PEEP in pig measurement. In an anesthetized pig, we performed multimodal recording on the torso and head involving electrical bioimpedance spectroscopy (EIS), fixed frequency impedance plethysmography (IPG), and bipolar (rheoencephalography - REG) measurements and processed data offline. Challenges (n=16) were PEEP, bleeding, change of SAP, and CO2 inhalation. The total measurement time was 4.12 hours. Systemic circulatory results: Bleeding caused a continuous decrease of SAP, cardiac output (CO), and increase of heart rate, temperature, shock index (SI), vegetative - Kerdo index (KI). Pulse pressure (PP) decreased only after second bleeding which coincided with loss of CBF AR. Pulmonary arterial pressure (PAP) increased during PEEP challenges as a function of time and bleeding. EIS/IPG results: Body fluid shift change was characterized by EIS-related variables. Electrical Impedance Spectroscopy was used to quantify the intravascular, interstitial, and intracellular volume changes during the application of PEEP and simulated hemorrhage. The intravascular fluid compartment was the primary source of blood during hemorrhage. PEEP produced a large fluid shift out of the intravascular compartment during the first bleeding period and continued to lose more blood following the second and third bleeding. Fixed frequency IPG was used to quantify the circulatory responses of the calf during PEEP and simulated hemorrhage. PEEP reduced the arterial blood flow into the calf and venous outflow from the calf. Head results: CBF AR was evaluated as a function of SAP change. Before bleeding, and after moderate bleeding, intracranial pressure (ICP), REG, and carotid flow pulse amplitudes (CFa) increased. This change reflected vasodilatation and active CBF AR. After additional hemorrhaging during PEEP, SAP, ICP, REG, CFa signal amplitudes decreased, indicating passive CBF AR. 1) The indicators of active AR status by modalities was the following: REG (n=9, 56 %), CFa (n=7, 44 %), and ICP (n=6, 38 %); 2) CBF reactivity was better for REG than ICP; 3) REG and ICP correlation coefficient were high (R2 = 0.81) during CBF AR active status; 4) PRx and REGx reflected active CBF AR status. CBF AR monitoring with REG offers safety for patients by preventing decreased CBF and secondary brain injury. We used different types of bioimpedance instrumentation to identify physiologic responses in the different parts of the body (that have not been discussed before) and how the peripheral responses ultimately lead to decreased cardiac output and changes in the head. These bioimpedance methods can improve ICU monitoring, increase the adequacy of therapy, and decrease mortality and morbidity.
Collapse
Affiliation(s)
| | | | - Michael Bodo
- Walter Reed Army Institute of Research, Silver Spring, MD, USA
- Current position: Ochsner Medical Center, New Orleans, LA, USA
| | | | | |
Collapse
|