1
|
Wang Y, Jian W, Zhu L, Cai C, Zhang B, Wang X. Attention-Gated Deep-Learning-Based Automatic Digitization of Interstitial Needles in High-Dose-Rate Brachytherapy for Cervical Cancer. Adv Radiat Oncol 2024; 9:101340. [PMID: 38260236 PMCID: PMC10801665 DOI: 10.1016/j.adro.2023.101340] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Accepted: 07/31/2023] [Indexed: 01/24/2024] Open
Abstract
Purpose Deep learning can be used to automatically digitize interstitial needles in high-dose-rate (HDR) brachytherapy for patients with cervical cancer. The aim of this study was to design a novel attention-gated deep-learning model, which may further improve the accuracy of and better differentiate needles. Methods and Materials Seventeen patients with cervical cancer with 56 computed tomography-based interstitial HDR brachytherapy plans from the local hospital were retrospectively chosen with the local institutional review board's approval. Among them, 50 plans were randomly selected as the training set and the rest as the validation set. Spatial and channel attention gates (AGs) were added to 3-dimensional convolutional neural networks (CNNs) to highlight needle features and suppress irrelevant regions; this was supposed to facilitate convergence and improve accuracy of automatic needle digitization. Subsequently, the automatically digitized needles were exported to the Oncentra treatment planning system (Elekta Solutions AB, Stockholm, Sweden) for dose evaluation. The geometric and dosimetric accuracy of automatic needle digitization was compared among 3 methods: (1) clinically approved plans with manual needle digitization (ground truth); (2) the conventional deep-learning (CNN) method; and (3) the attention-added deep-learning (CNN + AG) method, in terms of the Dice similarity coefficient (DSC), tip and shaft positioning errors, dose distribution in the high-risk clinical target volume (HR-CTV), organs at risk, and so on. Results The attention-gated CNN model was superior to CNN without AGs, with a greater DSC (approximately 94% for CNN + AG vs 89% for CNN). The needle tip and shaft errors of the CNN + AG method (1.1 mm and 1.8 mm, respectively) were also much smaller than those of the CNN method (2.0 mm and 3.3 mm, respectively). Finally, the dose difference for the HR-CTV D90 using the CNN + AG method was much more accurate than that using CNN (0.4% and 1.7%, respectively). Conclusions The attention-added deep-learning model was successfully implemented for automatic needle digitization in HDR brachytherapy, with clinically acceptable geometric and dosimetric accuracy. Compared with conventional deep-learning neural networks, attention-gated deep learning may have superior performance and great clinical potential.
Collapse
Affiliation(s)
- Yuenan Wang
- Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, Connecticut
| | - Wanwei Jian
- Department of Radiation Therapy, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Lin Zhu
- Department of Radiation Therapy, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Chunya Cai
- Department of Radiation Therapy, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Bailin Zhang
- Department of Radiation Therapy, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, China
| | - Xuetao Wang
- Department of Radiation Therapy, The Second Affiliated Hospital, Guangzhou University of Chinese Medicine, Guangzhou, China
| |
Collapse
|
2
|
Li Z, Yang Z, Lu J, Zhu Q, Wang Y, Zhao M, Li Z, Fu J. Deep learning-based dose map prediction for high-dose-rate brachytherapy. Phys Med Biol 2023; 68:175015. [PMID: 37589292 DOI: 10.1088/1361-6560/acecd2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 08/02/2023] [Indexed: 08/18/2023]
Abstract
Background. Creating a clinically acceptable plan in the time-sensitive clinic workflow of brachytherapy is challenging. Deep learning-based dose prediction techniques have been reported as promising solutions with high efficiency and accuracy. However, current dose prediction studies mainly target EBRT which are inappropriate for brachytherapy, the model designed specifically for brachytherapy has not yet well-established.Purpose. To predict dose distribution in brachytherapy using a novel Squeeze and Excitation Attention Net (SE_AN) model.Method. We hypothesized the tracks of192Ir inside applicators are essential for brachytherapy dose prediction. To emphasize the applicator contribution, a novel SE module was integrated into a Cascaded UNet to recalibrate informative features and suppress less useful ones. The Cascaded UNet consists of two stacked UNets, with the first designed to predict coarse dose distribution and the second added for fine-tuning 250 cases including all typical clinical applicators were studied, including vaginal, tandem and ovoid, multi-channel, and free needle applicators. The developed SE_AN was subsequently compared to the classic UNet and classic Cascaded UNet (without SE module) models. The model performance was evaluated by comparing the predicted dose against the clinically approved plans using mean absolute error (MAE) of DVH metrics, includingD2ccandD90%.Results. The MAEs of DVH metrics demonstrated that SE_AN accurately predicted the dose with 0.37 ± 0.25 difference for HRCTVD90%, 0.23 ± 0.14 difference for bladderD2cc, and 0.28 ± 0.20 difference for rectumD2cc. In comparison studies, UNet achieved 0.34 ± 0.24 for HRCTV, 0.25 ± 0.20 for bladder, 0.25 ± 0.21 for rectum, and Cascaded UNet achieved 0.42 ± 0.31 for HRCTV, 0.24 ± 0.19 for bladder, 0.23 ± 0.19 for rectum.Conclusion. We successfully developed a method specifically for 3D brachytherapy dose prediction. Our model demonstrated comparable performance to clinical plans generated by experienced dosimetrists. The developed technique is expected to improve the standardization and quality control of brachytherapy treatment planning.
Collapse
Affiliation(s)
- Zhen Li
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Zhenyu Yang
- Duke University, Durham, NC, United States of America
| | - Jiayu Lu
- Boston University, Boston, MA, United States of America
| | - Qingyuan Zhu
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Yanxiao Wang
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Mengli Zhao
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Zhaobin Li
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| | - Jie Fu
- Shanghai Sixth People's Hospital, Shanghai, People's Republic of China
| |
Collapse
|
3
|
Kallis K, Moore LC, Cortes KG, Brown D, Mayadev J, Moore KL, Meyers SM. Automated treatment planning framework for brachytherapy of cervical cancer using 3D dose predictions. Phys Med Biol 2023; 68:10.1088/1361-6560/acc37c. [PMID: 36898161 PMCID: PMC10101723 DOI: 10.1088/1361-6560/acc37c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2022] [Accepted: 03/10/2023] [Indexed: 03/12/2023]
Abstract
Objective. To lay the foundation for automated knowledge-based brachytherapy treatment planning using 3D dose estimations, we describe an optimization framework to convert brachytherapy dose distributions directly into dwell times (DTs).Approach. A dose rate kernelḋ(r,θ,φ)was produced by exporting 3D dose for one dwell position from the treatment planning system and normalizing by DT. By translating and rotating this kernel to each dwell position, scaling by DT and summing over all dwell positions, dose was computed (Dcalc). We used a Python-coded COBYLA optimizer to iteratively determine the DTs that minimize the mean squared error betweenDcalcand reference doseDref, computed using voxels withDref80%-120% of prescription. As validation of the optimization, we showed that the optimizer replicates clinical plans whenDref= clinical dose in 40 patients treated with tandem-and-ovoid (T&O) or tandem-and-ring (T&R) and 0-3 needles. Then we demonstrated automated planning in 10 T&O usingDref= dose predicted from a convolutional neural network developed in past work. Validation and automated plans were compared to clinical plans using mean absolute differences (MAD=1N∑n=1Nabsxn-xn') over all voxels (xn= Dose,N= #voxels) and DTs (xn= DT,N= #dwell positions), mean differences (MD) in organD2ccand high-risk CTV D90 over all patients (where positive indicates higher clinical dose), and mean Dice similarity coefficients (DSC) for 100% isodose contours.Main results. Validation plans agreed well with clinical plans (MADdose= 1.1%, MADDT= 4 s or 0.8% of total plan time,D2ccMD = -0.2% to 0.2% and D90 MD = -0.6%, DSC = 0.99). For automated plans, MADdose= 6.5% and MADDT= 10.3 s (2.1%). The slightly higher clinical metrics in automated plans (D2ccMD = -3.8% to 1.3% and D90 MD = -5.1%) were due to higher neural network dose predictions. The overall shape of the automated dose distributions were similar to clinical doses (DSC = 0.91).Significance. Automated planning with 3D dose predictions could provide significant time savings and standardize treatment planning across practitioners, regardless of experience.
Collapse
Affiliation(s)
- Karoline Kallis
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA, United States of America
| | - Lance C Moore
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA, United States of America
| | - Katherina G Cortes
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA, United States of America
| | - Derek Brown
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA, United States of America
| | - Jyoti Mayadev
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA, United States of America
| | - Kevin L Moore
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA, United States of America
| | - Sandra M Meyers
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA, United States of America
| |
Collapse
|
4
|
|
5
|
Li Z, Zhu Q, Zhang L, Yang X, Li Z, Fu J. A deep learning-based self-adapting ensemble method for segmentation in gynecological brachytherapy. Radiat Oncol 2022; 17:152. [PMID: 36064571 PMCID: PMC9446699 DOI: 10.1186/s13014-022-02121-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2022] [Accepted: 08/29/2022] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Fast and accurate outlining of the organs at risk (OARs) and high-risk clinical tumor volume (HRCTV) is especially important in high-dose-rate brachytherapy due to the highly time-intensive online treatment planning process and the high dose gradient around the HRCTV. This study aims to apply a self-configured ensemble method for fast and reproducible auto-segmentation of OARs and HRCTVs in gynecological cancer. MATERIALS AND METHODS We applied nnU-Net (no new U-Net), an automatically adapted deep convolutional neural network based on U-Net, to segment the bladder, rectum and HRCTV on CT images in gynecological cancer. In nnU-Net, three architectures, including 2D U-Net, 3D U-Net and 3D-Cascade U-Net, were trained and finally ensembled. 207 cases were randomly chosen for training, and 30 for testing. Quantitative evaluation used well-established image segmentation metrics, including dice similarity coefficient (DSC), 95% Hausdorff distance (HD95%), and average surface distance (ASD). Qualitative analysis of automated segmentation results was performed visually by two radiation oncologists. The dosimetric evaluation was performed by comparing the dose-volume parameters of both predicted segmentation and human contouring. RESULTS nnU-Net obtained high qualitative and quantitative segmentation accuracy on the test dataset and performed better than previously reported methods in bladder and rectum segmentation. In quantitative evaluation, 3D-Cascade achieved the best performance in the bladder (DSC: 0.936 ± 0.051, HD95%: 3.503 ± 1.956, ASD: 0.944 ± 0.503), rectum (DSC: 0.831 ± 0.074, HD95%: 7.579 ± 5.857, ASD: 3.6 ± 3.485), and HRCTV (DSC: 0.836 ± 0.07, HD95%: 7.42 ± 5.023, ASD: 2.094 ± 1.311). According to the qualitative evaluation, over 76% of the test data set had no or minor visually detectable errors in segmentation. CONCLUSION This work showed nnU-Net's superiority in segmenting OARs and HRCTV in gynecological brachytherapy cases in our center, among which 3D-Cascade shows the highest accuracy in segmentation across different applicators and patient anatomy.
Collapse
Affiliation(s)
- Zhen Li
- Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Xuhui District, Shanghai, China
| | - Qingyuan Zhu
- Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Xuhui District, Shanghai, China
| | - Lihua Zhang
- Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Xuhui District, Shanghai, China
| | - Xiaojing Yang
- Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Xuhui District, Shanghai, China
| | - Zhaobin Li
- Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Xuhui District, Shanghai, China
| | - Jie Fu
- Shanghai Jiao Tong University Affiliated Sixth People’s Hospital, Xuhui District, Shanghai, China
| |
Collapse
|
6
|
Song WY, Robar JL, Morén B, Larsson T, Carlsson Tedgren Å, Jia X. Emerging technologies in brachytherapy. Phys Med Biol 2021; 66. [PMID: 34710856 DOI: 10.1088/1361-6560/ac344d] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Accepted: 10/28/2021] [Indexed: 01/15/2023]
Abstract
Brachytherapy is a mature treatment modality. The literature is abundant in terms of review articles and comprehensive books on the latest established as well as evolving clinical practices. The intent of this article is to part ways and look beyond the current state-of-the-art and review emerging technologies that are noteworthy and perhaps may drive the future innovations in the field. There are plenty of candidate topics that deserve a deeper look, of course, but with practical limits in this communicative platform, we explore four topics that perhaps is worthwhile to review in detail at this time. First, intensity modulated brachytherapy (IMBT) is reviewed. The IMBT takes advantage ofanisotropicradiation profile generated through intelligent high-density shielding designs incorporated onto sources and applicators such to achieve high quality plans. Second, emerging applications of 3D printing (i.e. additive manufacturing) in brachytherapy are reviewed. With the advent of 3D printing, interest in this technology in brachytherapy has been immense and translation swift due to their potential to tailor applicators and treatments customizable to each individual patient. This is followed by, in third, innovations in treatment planning concerning catheter placement and dwell times where new modelling approaches, solution algorithms, and technological advances are reviewed. And, fourth and lastly, applications of a new machine learning technique, called deep learning, which has the potential to improve and automate all aspects of brachytherapy workflow, are reviewed. We do not expect that all ideas and innovations reviewed in this article will ultimately reach clinic but, nonetheless, this review provides a decent glimpse of what is to come. It would be exciting to monitor as IMBT, 3D printing, novel optimization algorithms, and deep learning technologies evolve over time and translate into pilot testing and sensibly phased clinical trials, and ultimately make a difference for cancer patients. Today's fancy is tomorrow's reality. The future is bright for brachytherapy.
Collapse
Affiliation(s)
- William Y Song
- Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, United States of America
| | - James L Robar
- Department of Radiation Oncology, Dalhousie University, Halifax, Nova Scotia, Canada
| | - Björn Morén
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Torbjörn Larsson
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Åsa Carlsson Tedgren
- Radiation Physics, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Oncology Pathology, Karolinska Institute, Stockholm, Sweden
| | - Xun Jia
- Innovative Technology Of Radiotherapy Computations and Hardware (iTORCH) Laboratory, Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, United States of America
| |
Collapse
|
7
|
Kallis K, Mayadev J, Kisling K, Brown D, Scanderbeg D, Ray X, Cortes K, Simon A, Yashar CM, Einck JP, Mell LK, Moore KL, Meyers SM. Knowledge-based dose prediction models to inform gynecologic brachytherapy needle supplementation for locally advanced cervical cancer. Brachytherapy 2021; 20:1187-1199. [PMID: 34393059 DOI: 10.1016/j.brachy.2021.07.001] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2021] [Revised: 06/16/2021] [Accepted: 07/01/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE The use of interstitial needles, combined with intracavitary applicators, enables customized dose distributions and is beneficial for complex cases, but increases procedure time. Overall, applicator selection is not standardized and depends on physician expertise and preference. The purpose of this study is to determine whether dose prediction models can guide needle supplementation decision-making for cervical cancer. MATERIALS AND METHODS Intracavitary knowledge-based models for organ-at-risk (OAR) dose estimation were trained and validated for tandem-and-ring/ovoids (T&R/T&O) implants. Models were applied to hybrid cases with 1-3 implanted needles to predict OAR dose without needles. As a reference, 70/67 hybrid T&R/T&O cases were replanned without needles, following a standardized procedure guided by dose predictions. If a replanned dose exceeded the dose objective, the case was categorized as requiring needles. Receiver operating characteristic (ROC) curves of needle classification accuracy were generated. Optimal classification thresholds were determined from the Youden Index. RESULTS Needle supplementation reduced dose to OARs. However, 67%/39% of replans for T&R/T&O met all dose constraints without needles. The ROC for T&R/T&O models had an area-under-curve of 0.89/0.86, proving high classification accuracy. The optimal threshold of 99%/101% of the dose limit for T&R/T&O resulted in classification sensitivity and specificity of 78%/86% and 85%/78%. CONCLUSIONS Needle supplementation reduced OAR dose for most cases but was not always required to meet standard dose objectives, particularly for T&R cases. Our knowledge-based dose prediction model accurately identified cases that could have met constraints without needle supplementation, suggesting that such models may be beneficial for applicator selection.
Collapse
Affiliation(s)
- Karoline Kallis
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Jyoti Mayadev
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Kelly Kisling
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Derek Brown
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Daniel Scanderbeg
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Xenia Ray
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Katherina Cortes
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Aaron Simon
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Catheryn M Yashar
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - John P Einck
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Loren K Mell
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Kevin L Moore
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA
| | - Sandra M Meyers
- Department of Radiation Medicine & Applied Sciences, UC San Diego Health, San Diego, CA.
| |
Collapse
|
8
|
Morén B, Larsson T, Tedgren ÅC. Optimization in treatment planning of high dose-rate brachytherapy - Review and analysis of mathematical models. Med Phys 2021; 48:2057-2082. [PMID: 33576027 DOI: 10.1002/mp.14762] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 11/12/2020] [Accepted: 01/22/2021] [Indexed: 12/12/2022] Open
Abstract
Treatment planning in high dose-rate brachytherapy has traditionally been conducted with manual forward planning, but inverse planning is today increasingly used in clinical practice. There is a large variety of proposed optimization models and algorithms to model and solve the treatment planning problem. Two major parts of inverse treatment planning for which mathematical optimization can be used are the decisions about catheter placement and dwell time distributions. Both these problems as well as integrated approaches are included in this review. The proposed models include linear penalty models, dose-volume models, mean-tail dose models, quadratic penalty models, radiobiological models, and multiobjective models. The aim of this survey is twofold: (i) to give a broad overview over mathematical optimization models used for treatment planning of brachytherapy and (ii) to provide mathematical analyses and comparisons between models. New technologies for brachytherapy treatments and methods for treatment planning are also discussed. Of particular interest for future research is a thorough comparison between optimization models and algorithms on the same dataset, and clinical validation of proposed optimization approaches with respect to patient outcome.
Collapse
Affiliation(s)
- Björn Morén
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Torbjörn Larsson
- Department of Mathematics, Linköping University, Linköping, Sweden
| | - Åsa Carlsson Tedgren
- Radiation Physics, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden.,Medical Radiation Physics and Nuclear Medicine, Karolinska University Hospital, Stockholm, Sweden.,Department of Oncology Pathology, Karolinska Institute, Stockholm, Sweden
| |
Collapse
|
9
|
Wang X, Wang P, Tang B, Kang S, Hou Q, Wu Z, Gou C, Li L, Orlandini L, Lang J, Li J. An Inverse Dose Optimization Algorithm for Three-Dimensional Brachytherapy. Front Oncol 2020; 10:564580. [PMID: 33194640 PMCID: PMC7606999 DOI: 10.3389/fonc.2020.564580] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 09/30/2020] [Indexed: 12/24/2022] Open
Abstract
PURPOSE To investigate an implementation method and the results of an inverse dose optimization algorithm, Gradient Based Planning Optimization (GBPO), for three-dimensional brachytherapy. METHODS The GBPO used a quadratic objective function, and a dwell time modulation item was added to the objective function to restrict the dwell time variance. We retrospectively studied 4 cervical cancer patients using different applicators and 15 cervical cancer patients using the Fletcher applicator. We assessed the plan quality of GBPO by isodose lines for the patients using different applicators. For the 15 patients using the Fletcher applicator, we utilized dose-volume histogram (DVH) parameters of HR-CTV (D100%, V150%) and organs at risk (OARs) (D0.1cc, D1cc, D2cc) to evaluate the difference between the GBPO plans and the IPSA (Inverse Planning Simulated Annealing) plans, as well as the GBPO plans and the Graphic plans. RESULTS For the 4 patients using different applicators, the dose distributions are conformable. For the 15 patients using the Fletcher applicator, when the dwell time modulation factor (DTMF) is less than 20, the dwell time deviation reduces quickly; however, after the DTMF increased to 100, the dwell time deviation has no remarkable change. The difference in dosimetric parameters between the GBPO plans and the IPSA plans is not statistically significant (P>0.05). The GBPO plans have a higher D100% (3.57 ± 0.36, 3.38 ± 0.34; P<0.01) and a lower V150% (55.73 ± 4.06, 57.75 ± 3.79; P<0.01) than those of the Graphic plans. The differences in other DVH parameters are negligible between the GBPO plans and the Graphic plans. CONCLUSIONS The GBPO plans have a comparable quality as the IPSA plans and the Graphic plans for the studied cervical cancer cases. The GBPO algorithm could be integrated into a three-dimensional brachytherapy treatment planning system after studying more sites.
Collapse
Affiliation(s)
- Xianliang Wang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| | - Pei Wang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| | - Bin Tang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| | - Shengwei Kang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| | - Qing Hou
- Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China
| | - Zhangwen Wu
- Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China
| | - Chengjun Gou
- Key Laboratory of Radiation Physics and Technology, Institute of Nuclear Science and Technology, Sichuan University, Chengdu, China
| | - Lintao Li
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| | - Lucia Orlandini
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| | - Jinyi Lang
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| | - Jie Li
- Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, School of Medicine, University of Electronic Science and Technology of China, Radiation Oncology Key Laboratory Of Sichuan Province, Chengdu, China
| |
Collapse
|
10
|
Yusufaly TI, Kallis K, Simon A, Mayadev J, Yashar CM, Einck JP, Mell LK, Brown D, Scanderbeg D, Hild SJ, Covele B, Moore KL, Meyers SM. A knowledge-based organ dose prediction tool for brachytherapy treatment planning of patients with cervical cancer. Brachytherapy 2020; 19:624-634. [PMID: 32513446 DOI: 10.1016/j.brachy.2020.04.008] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2020] [Revised: 04/03/2020] [Accepted: 04/19/2020] [Indexed: 10/24/2022]
Abstract
PURPOSE The purpose of this study is to explore knowledge-based organ-at-risk dose estimation for intracavitary brachytherapy planning for cervical cancer. Using established external-beam knowledge-based dose-volume histogram (DVH) estimation methods, we sought to predict bladder, rectum, and sigmoid D2cc for tandem and ovoid treatments. METHODS AND MATERIALS A total of 136 patients with loco-regionally advanced cervical cancer treated with 456 (356:100 training:validation ratio) CT-based tandem and ovoid brachytherapy fractions were analyzed. Single fraction prescription doses were 5.5-8 Gy with dose criteria for the high-risk clinical target volume, bladder, rectum, and sigmoid. DVH estimations were obtained by subdividing training set organs-at-risk into high-risk clinical target volume boundary distance subvolumes and computing cohort-averaged differential DVHs. Full DVH estimation was then performed on the training and validation sets. Model performance was quantified by ΔD2cc = D2cc(actual)-D2cc(predicted) (mean and standard deviation). ΔD2cc between training and validation sets were compared with a Student's t test (p < 0.01 significant). Categorical variables (physician, fraction-number, total fractions, and case complexity) that might explain model variance were examined using an analysis of variance test (Bonferroni-corrected p < 0.01 threshold). RESULTS Training set deviations were bladder ΔD2cc = -0.04 ± 0.61 Gy, rectum ΔD2cc = 0.02 ± 0.57 Gy, and sigmoid ΔD2cc = -0.05 ± 0.52 Gy. Model predictions on validation set did not statistically differ: bladder ΔD2cc = -0.02 ± 0.46 Gy (p = 0.80), rectum ΔD2cc = -0.007 ± 0.47 Gy (p = 0.53), and sigmoid ΔD2cc = -0.07 ± 0.47 Gy (p = 0.70). The only significant categorical variable was the attending physician for bladder and rectum ΔD2cc. CONCLUSION: A simple boundary distance-driven knowledge-based DVH estimation exhibited promising results in predicting critical brachytherapy dose metrics. Future work will examine the utility of these predictions for quality control and automated brachytherapy planning.
Collapse
Affiliation(s)
- Tahir I Yusufaly
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Karoline Kallis
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Aaron Simon
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Jyoti Mayadev
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Catheryn M Yashar
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - John P Einck
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Loren K Mell
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Derek Brown
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Daniel Scanderbeg
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Sebastian J Hild
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Brent Covele
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Kevin L Moore
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA
| | - Sandra M Meyers
- Department of Radiation Medicine and Applied Sciences, University of California, San Diego, La Jolla, CA.
| |
Collapse
|
11
|
Simiele SJ, Chen X, Lee C, Rosen BS, Mikell JK, Moran JM, Prisciandaro JI. Development and comprehensive commissioning of an automated brachytherapy plan checker. Brachytherapy 2020; 19:355-361. [DOI: 10.1016/j.brachy.2020.02.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2019] [Revised: 02/13/2020] [Accepted: 02/13/2020] [Indexed: 11/26/2022]
|
12
|
Cunha JAM, Flynn R, Bélanger C, Callaghan C, Kim Y, Jia X, Chen Z, Beaulieu L. Brachytherapy Future Directions. Semin Radiat Oncol 2020; 30:94-106. [DOI: 10.1016/j.semradonc.2019.09.001] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
|
13
|
Jung H, Shen C, Gonzalez Y, Albuquerque K, Jia X. Deep-learning assisted automatic digitization of interstitial needles in 3D CT image based high dose-rate brachytherapy of gynecological cancer. Phys Med Biol 2019; 64:215003. [PMID: 31470425 DOI: 10.1088/1361-6560/ab3fcb] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Digitization of interstitial needles is a complicated and tedious process for the treatment planning of 3D CT image based interstitial high dose-rate brachytherapy (HDRBT) of gynecological cancer. We developed a deep-learning assisted auto-digitization method for interstitial needles. The digitization method consisted of two steps. The first step used a deep neural network with a U-net structure to segment all needles from CT images. The second step simultaneously clustered the segmented voxels into different needle groups and generated the needle central trajectories by solving an optimization problem. We evaluated the effectiveness of the developed method in ten interstitial HDRBT patient cases that were not used in the training of the U-net. Average number of needles per case was 20.7. For the segmentation step, average Dice similarity coefficient between automatic and manual segmentation was 0.93. For the digitization step, Hausdorff distance between needle trajectories determined by our method and manually by qualified medical physicists was ~0.71 mm on average and mean difference of tip positions was ~0.63 mm, which were considered acceptable for HDRBT treatment planning. It took ~5 min to complete the digitization process of an interstitial HDRBT case. The achieved accuracy and efficiency made our method clinically attractive.
Collapse
Affiliation(s)
- Hyunuk Jung
- Medical Artificial Intelligence and Automation (MAIA) Lab, University of Texas Southwestern Medical Center, Dallas, TX 75235, United States of America. Innovative Technology Of Radiotherapy Computation and Hardware (iTORCH) Lab, University of Texas Southwestern Medical Center, Dallas, TX 75235, United States of America. Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX 75235, United States of America
| | | | | | | | | |
Collapse
|
14
|
Deufel CL, Tian S, Yan BB, Vaishnav BD, Haddock MG, Petersen IA. Automated applicator digitization for high-dose-rate cervix brachytherapy using image thresholding and density-based clustering. Brachytherapy 2019; 19:111-118. [PMID: 31594729 DOI: 10.1016/j.brachy.2019.09.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Revised: 08/13/2019] [Accepted: 09/09/2019] [Indexed: 10/25/2022]
Abstract
PURPOSE The purpose of the study was to develop and evaluate an automated digitization algorithm for high-dose-rate cervix brachytherapy, with the goal of reducing the duration of treatment planning, staff resources, variability, and potential for human error. METHODS An automated digitization algorithm was developed and retrospectively evaluated using treatment planning data from 10 patients with cervix cancer who were treated with a titanium tandem and ovoids applicator set. Applicators were segmented, without human interaction, by thresholding CT images to isolate high-density voxels and assigning the voxels to applicator and nonapplicator structures using HDBSCAN, a density-based linkage clustering algorithm. The applicator contours were determined from the centroid of the clustered voxels on each image slice and written to a treatment plan file. Automated contours were evaluated against manual digitization using distance and dosimetric metrics. RESULTS A close agreement between automatic and manual digitization was observed. The mean magnitude of contour disagreement for 10 patients equaled 0.3 mm. Hausdorff distances were ≤1.0 mm. The applicator tip coordinates had submillimeter agreement. The median and mean dose volume histogram parameter differences were less than or equal to 1% for high-risk clinical target volume D90, high-risk clinical target volume D95, bladder D2cc, rectum D2cc, large bowel D2cc, and small bowel D2cc. The average execution time for the automated algorithm was less than 30 s. CONCLUSION The digitization of titanium tandem and ovoids applicators for high-dose-rate brachytherapy treatment planning can be automated using straightforward thresholding and clustering algorithms. The adoption of automated digitization is expected to improve the consistency of treatment plans and reduce the duration of treatment planning.
Collapse
Affiliation(s)
| | - Shulan Tian
- Division of Biomedical Statistics and Informatics, Department of Health Sciences Research, Mayo Clinic, Rochester, MN
| | - Benjamin B Yan
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN
| | | | | | - Ivy A Petersen
- Department of Radiation Oncology, Mayo Clinic, Rochester, MN
| |
Collapse
|
15
|
Hrinivich WT, Morcos M, Viswanathan A, Lee J. Automatic tandem and ring reconstruction using MRI for cervical cancer brachytherapy. Med Phys 2019; 46:4324-4332. [PMID: 31329302 DOI: 10.1002/mp.13730] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2019] [Revised: 06/19/2019] [Accepted: 07/06/2019] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The MRI-guided cervical cancer brachytherapy provides unparalleled soft-tissue contrast for target and normal tissue contouring, but eliminates the ability to use conventional metallic fiducials for radiation source path reconstruction as required for treatment planning. Instead, the source path is reconstructed by manually aligning a library model to the signal void produced by the applicator, which takes time intraoperatively and precludes fully automated treatment planning. The purpose of this study is to present and validate an algorithm to automatically reconstruct tandem and ring applicators using MRI for cervical cancer brachytherapy treatment planning. METHODS Applicators were reconstructed using T2-weighted MR images acquired at 1.5 T from 33 brachytherapy fractions including 10 patients using a model-to-image registration algorithm. The algorithm involves (a) image filtering and maximum intensity projection to highlight the applicator, (b) ring center identification using the circular Hough transform, and (c) three-dimensional surface model registration, optimized by maximizing the image intensity gradient normal to the model surface. Two independent observers manually reconstructed all applicators, enabling the calculation of interobserver variability and establishing a ground truth. Algorithm variability was calculated by comparing algorithm results to each individual observer, and algorithm accuracy was calculated by comparing algorithm results to the ground truth. The algorithm variability and accuracy were compared to the interobserver variability using paired t-tests. RESULTS Mean ± SD interobserver variability was 0.83 ± 0.31 mm and 0.78 ± 0.29 mm for the ring and tandem, respectively. The algorithm had mean ± SD variability and accuracy of 0.72 ± 0.32 mm (P = 0.02) and 0.60 ± 0.24 mm (P = 0.0005) for the ring, and 0.70 ± 0.29 mm (P = 0.11) and 0.58 ± 0.24 mm (P = 0.004) for the tandem, respectively. CONCLUSIONS The algorithm variability and accuracy were within the interobserver variability measured in this study. The algorithm accuracy and mean execution time of 10.0 s are sufficient for clinical tandem and ring reconstruction, and are a step toward fully automated tandem and ring brachytherapy treatment planning.
Collapse
Affiliation(s)
- William T Hrinivich
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, 21287, USA
| | - Marc Morcos
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, 21287, USA
| | - Akila Viswanathan
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, 21287, USA
| | - Junghoon Lee
- Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, MD, 21287, USA
| |
Collapse
|
16
|
Jung H, Gonzalez Y, Shen C, Klages P, Albuquerque K, Jia X. Deep-learning-assisted automatic digitization of applicators in 3D CT image-based high-dose-rate brachytherapy of gynecological cancer. Brachytherapy 2019; 18:841-851. [PMID: 31345749 DOI: 10.1016/j.brachy.2019.06.003] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2019] [Revised: 05/22/2019] [Accepted: 06/07/2019] [Indexed: 11/18/2022]
Abstract
PURPOSE Applicator digitization is one of the most critical steps in 3D high-dose-rate brachytherapy (HDRBT) treatment planning. Motivated by recent advances in deep-learning, we propose a deep-learning-assisted applicator digitization method for 3D CT image-based HDRBT. This study demonstrates its feasibility and potential in gynecological cancer HDRBT. METHODS AND MATERIALS Our method consisted of two steps. The first step used a U-net to segment applicator regions. We trained the U-net using two-dimensional CT images with a tandem-and-ovoid (T&O) applicator and corresponding applicator mask images. The second step applied a spectral clustering method and a polynomial curve fitting method to extract applicator central paths. We evaluated the accuracy, efficiency, and robustness of our method in different scenarios including other T&O cases that were not used in training, a T&O case scanned with cone-beam CT, and Y-tandem and cylinder-applicator cases. RESULTS In test cases with a T&O applicator, average 3D Dice similarity coefficient between automatic and manual segmented applicator regions was 0.93. Average distance between tip positions and average Hausdorff distance between applicator channels determined by our method and manually were 0.64 mm and 0.68 mm, respectively. Although trained only using CT images of T&O cases, our tool can also digitize Y-tandem, cylinder applicator, and T&O applicator scanned in cone-beam CT with error of tip position and Hausdorff distance <1 mm. Computation time was ∼15 s per case. CONCLUSIONS We have developed a deep-learning-assisted applicator digitization tool for 3D CT image-based HDRBT of gynecological cancer. The achieved accuracy, efficiency, and robustness made our tool clinically attractive.
Collapse
Affiliation(s)
- Hyunuk Jung
- Innovation Technology of Radiotherapy Computation and Hardware (iTORCH) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Medical Artificial Intelligence and Automation (MAIA) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Yesenia Gonzalez
- Innovation Technology of Radiotherapy Computation and Hardware (iTORCH) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Medical Artificial Intelligence and Automation (MAIA) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Chenyang Shen
- Innovation Technology of Radiotherapy Computation and Hardware (iTORCH) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Medical Artificial Intelligence and Automation (MAIA) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Peter Klages
- Innovation Technology of Radiotherapy Computation and Hardware (iTORCH) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Medical Artificial Intelligence and Automation (MAIA) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Kevin Albuquerque
- Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX
| | - Xun Jia
- Innovation Technology of Radiotherapy Computation and Hardware (iTORCH) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Medical Artificial Intelligence and Automation (MAIA) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX.
| |
Collapse
|
17
|
Bélanger C, Cui S, Ma Y, Després P, Adam M Cunha J, Beaulieu L. A GPU-based multi-criteria optimization algorithm for HDR brachytherapy. ACTA ACUST UNITED AC 2019; 64:105005. [DOI: 10.1088/1361-6560/ab1817] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
18
|
Cui S, Després P, Beaulieu L. A multi-criteria optimization approach for HDR prostate brachytherapy: II. Benchmark against clinical plans. ACTA ACUST UNITED AC 2018; 63:205005. [DOI: 10.1088/1361-6560/aae24f] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
19
|
Partridge M, Oelfke U. Recent progress in applications of computing to radiotherapy (ICCR 2016). Phys Med Biol 2017. [DOI: 10.1088/1361-6560/aa6b3c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|