1
|
Riis HL, Chick J, Dunlop A, Tilly D. The Quality Assurance of a 1.5 T MR-Linac. Semin Radiat Oncol 2024; 34:120-128. [PMID: 38105086 DOI: 10.1016/j.semradonc.2023.10.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
The recent introduction of a commercial 1.5 T MR-linac system has considerably improved the image quality of the patient acquired in the treatment unit as well as enabling online adaptive radiation therapy (oART) treatment strategies. Quality Assurance (QA) of this new technology requires new methodology that allows for the high field MR in a linac environment. The presence of the magnetic field requires special attention to the phantoms, detectors, and tools to perform QA. Due to the design of the system, the integrated megavoltage imager (MVI) is essential for radiation beam calibrations and QA. Additionally, the alignment between the MR image system and the radiation isocenter must be checked. The MR-linac system has vendor-supplied phantoms for calibration and QA tests. However, users have developed their own routine QA systems to independently check that the machine is performing as required, as to ensure we are able to deliver the intended dose with sufficient certainty. The aim of this work is therefore to review the MR-linac specific QA procedures reported in the literature.
Collapse
Affiliation(s)
- Hans Lynggaard Riis
- Department of Oncology, Odense University Hospital, Odense, Denmark; Department of Clinical Research, University of Southern Denmark, Odense, Denmark.
| | - Joan Chick
- The Joint Department of Physics, The Royal Marsden Hospital and the Institute of Cancer Research, London, UK
| | - Alex Dunlop
- The Joint Department of Physics, The Royal Marsden Hospital and the Institute of Cancer Research, London, UK
| | - David Tilly
- Department of Immunology, Genetics and Pathology, Medical Radiation Physics, Uppsala University, Uppsala, Sweden; Medical Physics, Uppsala University Hospital, Uppsala, Sweden
| |
Collapse
|
2
|
Mönnich D, Winter J, Nachbar M, Künzel L, Boeke S, Gani C, Dohm O, Zips D, Thorwarth D. Quality assurance of IMRT treatment plans for a 1.5 T MR-linac using a 2D ionization chamber array and a static solid phantom. Phys Med Biol 2020; 65:16NT01. [PMID: 32663819 DOI: 10.1088/1361-6560/aba5ec] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
MR-guided radiotherapy requires novel quality assurance (QA) methods for intensity-modulated radiotherapy treatment plans (TPs). Here, an optimized method for TPs for a 1.5 T MR-linac was developed and implemented clinically. A static solid phantom and an MR-compatible 2D ionization chamber array were used. The array's response with respect to the incident beam gantry angles was characterized for four different orientations of the array relative to the beam. A lookup table was created identifying the optimum orientation for each gantry angle. For the QA of clinical MR-linac TPs, beams were grouped according to their gantry angles and measured with up to four setups. The method was applied to n = 106 clinical TPs of 54 patients for different tumour entities. Reference plans and plans created in the online adaptive workflow were analysed, using a local 3%/3 mm gamma criterion for dose values larger than 30% of the maximum. Pass rates were averaged over all beam groups. The array's response strongly depends on the beam incidence angle. Optimum angles typically range from -10° to 80° around the phantom setup angle. Consequently, plan verification required up to four setups. For clinical MR-linac TPs, the overall median pass rate was 98.5% (range 88.6%-100%). Pass rates depended on the tumour entity. Median pass rates were for liver metastases stereotactic body radiotherapy 99.2%, prostate cancer 99%, pancreatic cancer 98.9%, lymph node metastases 98.7%, partial breast irradiation (PBI) 98%, head-and-neck cancer 97.7%, rectal cancer 94% and others 96.6%. 85% of plans were accepted straightaway, with pass rates above 95%. A single plan with a pass rate below 90% was subsequently verified with a modified method. Off-axis target volumes, e.g. PBI, were verified successfully using a lateral shift of the phantom. The method is suitable to verify reference and online adapted TPs for a 1.5 T MR-linac, including plans for off-axis target volumes.
Collapse
Affiliation(s)
- David Mönnich
- Section for Biomedical Physics, Department of Radiation Oncology, Eberhard Karls University Tübingen, Germany. German Cancer Consortium (DKTK) and German Cancer Research Center (DKFZ), Heidelberg, Germany. Author to whom any correspondence should be addressed
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Esposito M, Villaggi E, Bresciani S, Cilla S, Falco MD, Garibaldi C, Russo S, Talamonti C, Stasi M, Mancosu P. Estimating dose delivery accuracy in stereotactic body radiation therapy: A review of in-vivo measurement methods. Radiother Oncol 2020; 149:158-167. [PMID: 32416282 DOI: 10.1016/j.radonc.2020.05.014] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2019] [Revised: 05/08/2020] [Accepted: 05/10/2020] [Indexed: 12/25/2022]
Abstract
Stereotactic body radiation therapy (SBRT) has been recognized as a standard treatment option for many anatomical sites. Sophisticated radiation therapy techniques have been developed for carrying out these treatments and new quality assurance (QA) programs are therefore required to guarantee high geometrical and dosimetric accuracy. This paper focuses on recent advances on in-vivo measurements methods (IVM) for SBRT treatment. More specifically, all of the online QA methods for estimating the effective dose delivered to patients were compared. Determining the optimal IVM for performing SBRT treatments would reduce the risk of errors that could jeopardize treatment outcome. A total of 89 papers were included. The papers were subdivided into the following topics: point dosimeters (PD), transmission detectors (TD), log file analysis (LFA), electronic portal imaging device dosimetry (EPID), dose accumulation methods (DAM). The detectability capability of the main IVM detectors/devices were evaluated. All of the systems have some limitations: PD has no spatial data, EPID has limited sensitivity towards set-up errors and intra-fraction motion in some anatomical sites, TD is insensitive towards patient related errors, LFA is not an independent measure, DAMs are not always based on measures. In order to minimize errors in SBRT dose delivery, we recommend using synergic combinations of two or more of the systems described in our review: on-line tumor position and patient information should be combined with MLC position and linac output detection accuracy. In this way the effects of SBRT dose delivery errors will be reduced.
Collapse
Affiliation(s)
- Marco Esposito
- S.C. Fisica Sanitaria Firenze-Empoli, Azienda Sanitaria USL Toscana Centro, Italy.
| | | | - Sara Bresciani
- Medical Physics, Candiolo Cancer Institute - FPO IRCCS, Turin, Italy
| | - Savino Cilla
- Medical Physics Unit, Gemelli Molise Hospital, Campobasso, Italy
| | - Maria Daniela Falco
- Department of Radiation Oncology "G. D'Annunzio", University of Chieti, SS. Annunziata Hospital, Chieti, Italy
| | - Cristina Garibaldi
- Radiation Research Unit, European Institute of Oncology IRCCS, Milan, Italy
| | - Serenella Russo
- S.C. Fisica Sanitaria Firenze-Empoli, Azienda Sanitaria USL Toscana Centro, Italy
| | - Cinzia Talamonti
- University of Florence, Dept Biomedical Experimental and Clinical Science, "Mario Serio", Medical Physics Unit, AOU Careggi, Florence, Italy
| | - Michele Stasi
- Medical Physics, Candiolo Cancer Institute - FPO IRCCS, Turin, Italy
| | - Pietro Mancosu
- Medical Physics Unit of Radiotherapy Dept., Humanitas Clinical and Research Hospital - IRCCS, Rozzano, Italy
| |
Collapse
|
4
|
Torres-Xirau I, Olaciregui-Ruiz I, Kaas J, Nowee ME, van der Heide UA, Mans A. 3D dosimetric verification of unity MR-linac treatments by portal dosimetry. Radiother Oncol 2020; 146:161-166. [PMID: 32182503 DOI: 10.1016/j.radonc.2020.02.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2019] [Revised: 02/11/2020] [Accepted: 02/12/2020] [Indexed: 11/16/2022]
Abstract
PURPOSE AND BACKGROUND 3D dosimetric verification of online adaptive workflows is essential as their complexity is unprecedented in radiation oncology. The aim of this work is to demonstrate the feasibility of back-projection portal dosimetry for 3D dosimetric verification of Unity MR-linac treatments. MATERIAL AND METHODS An earlier presented 2D back-projection algorithm for the Unity MR-linac geometry was extended for 3D dose reconstruction and comparison against planned dose distributions. 'In-air' as well as in-vivo portal EPID images can be used as input. The method was validated using data from treatments of 5 patients (2 rectal, 2 prostate cancer and one oligo metastasis). 3D pre-treatment verification of the reference plan using 'in-air' EPID images was performed and compared against measured (with the Octavius 4D system) and planned (in the planning CT) dose distributions. In-vivo EPID dose distributions were compared to the TPS for the first three adaptations of all treatments. For all comparisons, dose difference values at the reference point and γ-parameters were reported. RESULTS The comparison against the OCTAVIUS 4D system (3%, 2 mm, local) showed y-mean = 0.52 ± 0.10 and y-passrate = 91.9%, 95% CI [85.4, 98.4], and ΔDRP = -0.1 ± 1.1%. Pre-treatment verification against TPS data (3%, 2 mm, global) showed y-mean = 0.52 ± 0.04, y-passrate = 93.5%, 95% CI [92.4, 94.6] and ΔDRP = -0.9 ± 1.5%. The averaged y-results for the in-vivo 3D verification were y-mean = 0.52 ± 0.05, y-passrate = 92.5%, 95% CI [90.2, 94.8] and ΔDRP = 0.8 ± 2.1%. CONCLUSION 3D dosimetric verification of Unity MR-linac treatments using portal dosimetry is feasible, pre-treatment as well as in-vivo.
Collapse
Affiliation(s)
- Iban Torres-Xirau
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
| | - Igor Olaciregui-Ruiz
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
| | - Jochem Kaas
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Marlies E Nowee
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Uulke A van der Heide
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| | - Anton Mans
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands
| |
Collapse
|
5
|
|
6
|
Torres-Xirau I, Olaciregui-Ruiz I, van der Heide UA, Mans A. Two-dimensional EPID dosimetry for an MR-linac: Proof of concept. Med Phys 2019; 46:4193-4203. [PMID: 31199521 DOI: 10.1002/mp.13664] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 05/29/2019] [Accepted: 05/29/2019] [Indexed: 12/14/2022] Open
Abstract
PURPOSE At our institute, in vivo patient dose distributions are reconstructed for all treatments delivered using conventional linacs from electronic portal imaging device (EPID) transit images acquired during treatment using a simple back-projection model. Currently, the clinical implementation of MRI-guided radiotherapy systems, which aims for online and real-time adaptation of the treatment plan, is progressing. In our department, the MR-linac (Unity, Elekta AB, Stockholm, Sweden) is now in clinical use. The aim of this work is to demonstrate the feasibility of two-dimensional (2D) EPID dosimetric verification for the magnetic resonance (MR)-linac by comparing back-projected EPID doses to ionization chamber (IC) array dose distributions. MATERIALS AND METHODS Our conventional back-projection algorithm was adapted for the MR-linac. The most important changes involve modeling of the attenuation by and scatter from the cryostat. The commissioning process involved the acquisition of square field EPID measurements using various phantom setups (varying SSD, phantom thickness, and field size). Commissioning models were created for gantry 0°, 90°, and 180° and verified by comparing EPID-reconstructed 2D dose distributions to measurements made with the OCTAVIUS 1500 IC array (PTW, Freiburg, Germany) for two prostate and one rectum IMRT plans (25 beams total). The average of the γ parameters (y-mean and y-pass rate) and the dose difference at a reference point were reported. Due to their construction, the attenuation of couch, bridge, and cryostat shows a much stronger dependence on gantry angle in the MR-linac compared to conventional linacs. We present a method to correct for these effects. This method is validated by dose reconstruction of the 25 intensity-modulated radiation therapy beams recorded at a certain gantry angle using the model of another gantry angle, combined with the correction method. RESULTS For dose verification performed at a gantry angle identical to the commissioned model, the average y-mean and y-pass rate values (3% global dose, 2 mm, 10% isodose) were 0.37 ± 0.07 and 98.1, 95% CI [98.1 ± 2.4], respectively. The average dose difference at the reference point was -0.5% ± 1.8%. Verification at gantry angles different from the commissioned model (i.e., using the gantry angle dependent correction) reported 0.39 ± 0.08 and 97.6, 95% CI [96.9, 98.3] average y-mean and y-pass rate values. The average dose difference at the reference point was -0.1% ± 1.8%. CONCLUSION The EPID dosimetry back-projection model was successfully adapted for the MR-linac at gantry 0°, 90°, and 180°, accounting for the presence of the MRI housing between phantom (or patient) and the EPID. A method to account for the gantry angle dependence was also tested reporting similar results.
Collapse
Affiliation(s)
- Iban Torres-Xirau
- Department of Radiation Oncology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands
| | - Igor Olaciregui-Ruiz
- Department of Radiation Oncology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands
| | - Uulke A van der Heide
- Department of Radiation Oncology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands
| | - Anton Mans
- Department of Radiation Oncology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands
| |
Collapse
|
7
|
Pasler M, Hernandez V, Jornet N, Clark CH. Novel methodologies for dosimetry audits: Adapting to advanced radiotherapy techniques. Phys Imaging Radiat Oncol 2018; 5:76-84. [PMID: 33458373 PMCID: PMC7807589 DOI: 10.1016/j.phro.2018.03.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 03/08/2018] [Accepted: 03/08/2018] [Indexed: 11/25/2022] Open
Abstract
With new radiotherapy techniques, treatment delivery is becoming more complex and accordingly, these treatment techniques require dosimetry audits to test advanced aspects of the delivery to ensure best practice and safe patient treatment. This review of novel methodologies for dosimetry audits for advanced radiotherapy techniques includes recent developments and future techniques to be applied in dosimetry audits. Phantom-based methods (i.e. phantom-detector combinations) including independent audit equipment and local measurement equipment as well as phantom-less methods (i.e. portal dosimetry, transmission detectors and log files) are presented and discussed. Methodologies for both conventional linear accelerator (linacs) and new types of delivery units, i.e. Tomotherapy, stereotactic devices and MR-linacs, are reviewed. Novel dosimetry audit techniques such as portal dosimetry or log file evaluation have the potential to allow parallel auditing (i.e. performing an audit at multiple institutions at the same time), automation of data analysis and evaluation of multiple steps of the radiotherapy treatment chain. These methods could also significantly reduce the time needed for audit and increase the information gained. However, to maximise the potential, further development and harmonisation of dosimetry audit techniques are required before these novel methodologies can be applied.
Collapse
Affiliation(s)
- Marlies Pasler
- Lake Constance Radiation Oncology Center Singen-Friedrichshafen, Germany
| | - Victor Hernandez
- Department of Medical Physics, Hospital Sant Joan de Reus, IISPV, Tarragona, Spain
| | - Núria Jornet
- Servei de RadiofísicaiRadioprotecció, Hospital de la Santa CreuiSant Pau, Spain
| | - Catharine H. Clark
- Department of Medical Physics, Royal Surrey County Hospital, Guildford, Surrey, UK
- Metrology for Medical Physics (MEMPHYS), National Physical Laboratory, Teddington, Middlesex, UK
| |
Collapse
|