1
|
de Oliveira TF, Cavalheiro ACM, Buiochi F, Tsuzuki MSG, Leão-Neto JP, Silva GC, Silva GT, Henrique Lopes J. Ultrasonic characterization of 3D-printed polymer objects. ULTRASONICS 2025; 149:107572. [PMID: 39837083 DOI: 10.1016/j.ultras.2025.107572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2024] [Revised: 04/23/2024] [Accepted: 01/09/2025] [Indexed: 01/23/2025]
Abstract
3D printing technology, also known as Additive Manufacturing (AM), has revolutionized object prototyping, offering a simple, cost-effective, and efficient approach to creating structures with diverse spatial features. However, the mechanical properties of 3D-printed structures are highly dependent on the material type and manufacturing technique employed. In this study, ultrasonic testing methods were used to comprehensively characterize standard samples produced using two popular printing techniques: material extrusion and vat photopolymerization. The investigation focuses on seven commonly used 3D printing polymer materials, namely nylon, PET-G, flexible polymer, polycarbonate, acrylonitrile butadiene styrene (ABS), polylactic acid (PLA), and photopolymer resin. Through ultrasonic testing, the mechanical parameters of objects made of different polymer materials were found. Some of these parameters are Young's modulus, shear modulus, acoustic impedance, and absorption. A comparative analysis of these parameters in different objects provides insights about their respective performance and behavior. This information may be useful to enhance the design and performance of ultrasonic lenses and lab-on-a-chip devices. Findings indicate that the vat photopolymerization printing process yields high-quality samples that exhibit minimal deviations in thickness, diameter, and surface parallelism. Moreover, microscopic analysis of the vat photopolymerization samples revealed low levels of porosity, which suggests that the material can be considered homogeneous. In contrast, the material extrusion samples showed significant porosity in the form of gaps between the deposited filaments, which had a direct impact on their mechanical and acoustic properties.
Collapse
Affiliation(s)
- Timoteo F de Oliveira
- Department of Mechatronics and Mechanical Systems Engineering, University of Sao Paulo, Brazil
| | - André C M Cavalheiro
- Department of Mechatronics and Mechanical Systems Engineering, University of Sao Paulo, Brazil
| | - F Buiochi
- Department of Mechatronics and Mechanical Systems Engineering, University of Sao Paulo, Brazil
| | - Marcos S G Tsuzuki
- Department of Mechatronics and Mechanical Systems Engineering, University of Sao Paulo, Brazil
| | - José P Leão-Neto
- Acoustic and Application Group, Federal University of Alagoas, Campus Arapiraca, Brazil
| | | | - Glauber T Silva
- Physical Acoustics Group, Institute of Physics, Federal University of Alagoas, Brazil
| | - J Henrique Lopes
- Acoustic and Application Group, Federal University of Alagoas, Campus Arapiraca, Brazil.
| |
Collapse
|
2
|
Manuel TJ, Bancel T, Tiennot T, Didier M, Santin M, Daniel M, Attali D, Tanter M, Lehéricy S, Pyatigorskaya N, Aubry JF. Ultra-short time-echo based ray tracing for transcranial focused ultrasound aberration correction in human calvaria. Phys Med Biol 2025; 70:075006. [PMID: 38776944 DOI: 10.1088/1361-6560/ad4f44] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/22/2024] [Indexed: 05/25/2024]
Abstract
Objective.Magnetic resonance guided transcranial focused ultrasound holds great promises for treating neurological disorders. This technique relies on skull aberration correction which requires computed tomography (CT) scans of the skull of the patients. Recently, ultra-short time-echo (UTE) magnetic resonance (MR) sequences have unleashed the MRI potential to reveal internal bone structures. In this study, we measure the efficacy of transcranial aberration correction using UTE images.Approach.We compare the efficacy of transcranial aberration correction using UTE scans to CT based correction on four skulls and two targets using a clinical device (Exablate Neuro, Insightec, Israel). We also evaluate the performance of a custom ray tracing algorithm using both UTE and CT estimates of acoustic properties and compare these against the performance of the manufacturer's proprietary aberration correction software.Main results.UTE estimated skull maps in Hounsfield units (HU) had a mean absolute error of 242 ± 20 HU (n= 4). The UTE skull maps were sufficiently accurate to improve pressure at the target (no correction: 0.44 ± 0.10, UTE correction: 0.79 ± 0.05, manufacturer CT: 0.80 ± 0.05), pressure confinement ratios (no correction: 0.45 ± 0.10, UTE correction: 0.80 ± 0.05, manufacturer CT: 0.81 ± 0.05), and targeting error (no correction: 1.06 ± 0.42 mm, UTE correction 0.30 ± 0.23 mm, manufacturer CT: 0.32 ± 0.22) (n= 8 for all values). When using CT, our ray tracing algorithm performed slightly better than UTE based correction with pressure at the target (UTE: 0.79 ± 0.05, CT: 0.84 ± 0.04), pressure confinement ratios (UTE: 0.80 ± 0.05, CT: 0.84 ± 0.04), and targeting error (UTE: 0.30 ± 0.23 mm, CT: 0.17 ± 0.15).Significance.These 3D transcranial measurements suggest that UTE sequences could replace CT scans in the case of MR guided focused ultrasound with minimal reduction in performance which will avoid ionizing radiation exposure to the patients and reduce procedure time and cost.
Collapse
Affiliation(s)
- Thomas J Manuel
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8361, PSL University, Paris, France
| | - Thomas Bancel
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8361, PSL University, Paris, France
| | - Thomas Tiennot
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8361, PSL University, Paris, France
| | - Mélanie Didier
- Centre de Neuro-imagerie de Recherche (CENIR), Inserm U 1127, CNRS UMR 7225, Sorbonne Université, UPMC Univ Paris 06, UMR S 1127, Institut du Cerveau et de la Moelle (ICM), F-75013 Paris, France
| | - Mathieu Santin
- Centre de Neuro-imagerie de Recherche (CENIR), Inserm U 1127, CNRS UMR 7225, Sorbonne Université, UPMC Univ Paris 06, UMR S 1127, Institut du Cerveau et de la Moelle (ICM), F-75013 Paris, France
| | - Maxime Daniel
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8361, PSL University, Paris, France
| | - David Attali
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8361, PSL University, Paris, France
- GHU-Paris Psychiatrie et Neurosciences, Hôpital Sainte Anne, Université Paris Cité, 75014 Paris, France
| | - Mickael Tanter
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8361, PSL University, Paris, France
| | - Stéphane Lehéricy
- Centre de Neuro-imagerie de Recherche (CENIR), Inserm U 1127, CNRS UMR 7225, Sorbonne Université, UPMC Univ Paris 06, UMR S 1127, Institut du Cerveau et de la Moelle (ICM), F-75013 Paris, France
| | - Nadya Pyatigorskaya
- Centre de Neuro-imagerie de Recherche (CENIR), Inserm U 1127, CNRS UMR 7225, Sorbonne Université, UPMC Univ Paris 06, UMR S 1127, Institut du Cerveau et de la Moelle (ICM), F-75013 Paris, France
| | - Jean-François Aubry
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8361, PSL University, Paris, France
| |
Collapse
|
3
|
Burstow R, Andrés D, Jiménez N, Camarena F, Thanou M, Pouliopoulos AN. Acoustic holography in biomedical applications. Phys Med Biol 2025; 70:06TR01. [PMID: 39978080 DOI: 10.1088/1361-6560/adb89a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2024] [Accepted: 02/20/2025] [Indexed: 02/22/2025]
Abstract
Acoustic holography can be used to construct an arbitrary wavefront at a desired 2D plane or 3D volume by beam shaping an emitted field and is a relatively new technique in the field of biomedical applications. Acoustic holography was first theorized in 1985 following Gabor's work in creating optical holograms in the 1940s. Recent developments in 3D printing have led to an easier and faster way to manufacture monolithic acoustic holographic lenses that can be attached to single-element transducers. As ultrasound passes through the lens material, a phase shift is applied to the waves, causing an interference pattern at the 2D image plane or 3D volume, which forms the desired pressure field. This technology has many applications already in use and has become of increasing interest for the biomedical community, particularly for treating regions that are notoriously difficult to operate on, such as the brain. Acoustic holograms could provide a non-invasive, precise, and patient specific way to deliver drugs, induce hyperthermia, or create tissue cell patterns. However, there are still limitations in acoustic holography, such as the difficulties in creating 3D holograms and the passivity of monolithic lenses. This review aims to outline the biomedical applications of acoustic holograms reported to date and discuss their current limitations and the future work that is needed for them to reach their full potential in the biomedical community.
Collapse
Affiliation(s)
- Rachel Burstow
- Department of Surgical & Interventional Engineering, School of Biomedical Engineering Imaging Sciences, King's College London, London, United Kingdom
| | - Diana Andrés
- Instituto de Instrumentación para Imagen Molecular (I3M), CSIC-Universitat Politècnica de València, Valencia, Spain
| | - Noé Jiménez
- Instituto de Instrumentación para Imagen Molecular (I3M), CSIC-Universitat Politècnica de València, Valencia, Spain
| | - Francisco Camarena
- Instituto de Instrumentación para Imagen Molecular (I3M), CSIC-Universitat Politècnica de València, Valencia, Spain
| | - Maya Thanou
- Institute of Pharmaceutical Science, School of Cancer & Pharmaceutical Sciences, King's College London, London, United Kingdom
| | - Antonios N Pouliopoulos
- Department of Surgical & Interventional Engineering, School of Biomedical Engineering Imaging Sciences, King's College London, London, United Kingdom
| |
Collapse
|
4
|
Moonen CT, Kilroy JP, Klibanov AL. Focused Ultrasound: Noninvasive Image-Guided Therapy. Invest Radiol 2025; 60:205-219. [PMID: 39163359 PMCID: PMC11801465 DOI: 10.1097/rli.0000000000001116] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Accepted: 06/27/2024] [Indexed: 08/22/2024]
Abstract
ABSTRACT Invasive open surgery used to be compulsory to access tumor mass to perform excision or resection. Development of minimally invasive laparoscopic procedures followed, as well as catheter-based approaches, such as stenting, endovascular surgery, chemoembolization, brachytherapy, which minimize side effects and reduce the risks to patients. Completely noninvasive procedures bring further benefits in terms of reducing risk, procedure time, recovery time, potential of infection, or other side effects. Focusing ultrasound waves from the outside of the body specifically at the disease site has proven to be a safe noninvasive approach to localized ablative hyperthermia, mechanical ablation, and targeted drug delivery. Focused ultrasound as a medical intervention was proposed decades ago, but it only became feasible to plan, guide, monitor, and control the treatment procedures with advanced radiological imaging capabilities. The purpose of this review is to describe the imaging capabilities and approaches to perform these tasks, with the emphasis on magnetic resonance imaging and ultrasound. Some procedures already are in clinical practice, with more at the clinical trial stage. Imaging is fully integrated in the workflow and includes the following: (1) planning, with definition of the target regions and adjacent organs at risk; (2) real-time treatment monitoring via thermometry imaging, cavitation feedback, and motion control, to assure targeting and safety to adjacent normal tissues; and (3) evaluation of treatment efficacy, via assessment of ablation and physiological parameters, such as blood supply. This review also focuses on sonosensitive microparticles and nanoparticles, such as microbubbles injected in the bloodstream. They enable ultrasound energy deposition down to the microvascular level, induce vascular inflammation and shutdown, accelerate clot dissolution, and perform targeted drug delivery interventions, including focal gene delivery. Especially exciting is the ability to perform noninvasive drug delivery via opening of the blood-brain barrier at the desired areas within the brain. Overall, focused ultrasound under image guidance is rapidly developing, to become a choice noninvasive interventional radiology tool to treat disease and cure patients.
Collapse
|
5
|
Murphy KR, Nandi T, Kop B, Osada T, Lueckel M, N'Djin WA, Caulfield KA, Fomenko A, Siebner HR, Ugawa Y, Verhagen L, Bestmann S, Martin E, Butts Pauly K, Fouragnan E, Bergmann TO. A practical guide to transcranial ultrasonic stimulation from the IFCN-endorsed ITRUSST consortium. Clin Neurophysiol 2025; 171:192-226. [PMID: 39933226 DOI: 10.1016/j.clinph.2025.01.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 01/05/2025] [Accepted: 01/09/2025] [Indexed: 02/13/2025]
Abstract
Low-intensity Transcranial Ultrasonic Stimulation (TUS) is a non-invasive brain stimulation technique enabling cortical and deep brain targeting with unprecedented spatial accuracy. Given the high rate of adoption by new users with varying levels of expertise and interdisciplinary backgrounds, practical guidelines are needed to ensure state-of-the-art TUS application and reproducible outcomes. Therefore, the International Transcranial Ultrasonic Stimulation Safety and Standards (ITRUSST) consortium has formed a subcommittee, endorsed by the International Federation of Clinical Neurophysiology (IFCN), to develop recommendations for best practices in human TUS applications. The practical guide presented here provides a brief introduction into ultrasound physics and sonication parameters. It explains the requirements of TUS lab equipment and transducer selection and discusses experimental design and procedures alongside potential confounds and control conditions. Finally, the guide elaborates on essential steps of application planning for stimulation safety and efficacy, as well as considerations when combining TUS with neuroimaging, electrophysiology, or other brain stimulation techniques. We hope that this practical guide to TUS will assist both novice and experienced users in planning and conducting high-quality studies and provide a solid foundation for further advancements in this promising field.
Collapse
Affiliation(s)
- Keith R Murphy
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Tulika Nandi
- Neuroimaging Center, Focus Program Translational Neuroscience, Johannes Gutenberg University Medical Center, Mainz, Germany; Donders Institute for Brain, Cognition, and Behavior, Radboud University, Nijmegen, Netherlands
| | - Benjamin Kop
- Donders Institute for Brain, Cognition, and Behavior, Radboud University, Nijmegen, Netherlands
| | - Takahiro Osada
- Department of Neurophysiology, Juntendo University School of Medicine, Tokyo, Japan
| | - Maximilian Lueckel
- Neuroimaging Center, Focus Program Translational Neuroscience, Johannes Gutenberg University Medical Center, Mainz, Germany; Leibniz Institute for Resilience Research (LIR), Mainz, Germany
| | - W Apoutou N'Djin
- LabTAU, INSERM, Centre Léon Bérard, Université Claude Bernard Lyon 1, F-69003 Lyon, France
| | - Kevin A Caulfield
- Medical University of South Carolina, Department of Psychiatry & Behavioral Sciences, Charleston, SC, USA
| | - Anton Fomenko
- Krembil Research Institute, University Health Network, Toronto, Canada
| | - Hartwig R Siebner
- Danish Research Centre for Magnetic Resonance, Centre for Functional and Diagnostic Imaging and Research, Copenhagen University Hospital Amager and Hvidovre, Hvidovre, Denmark; Department of Neurology, Copenhagen University Hospital Bispebjerg and Frederiksberg, Copenhagen, Denmark; Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark
| | - Yoshikazu Ugawa
- Department of Human Neurophysiology, Fukushima Medical University, Fukushima, Japan
| | - Lennart Verhagen
- Donders Institute for Brain, Cognition, and Behavior, Radboud University, Nijmegen, Netherlands
| | - Sven Bestmann
- Department of Clinical and Movement Neuroscience, UCL Queen Square Institute of Neurology, University College London, UK
| | - Eleanor Martin
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK; Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London, UK
| | - Kim Butts Pauly
- Department of Radiology, Stanford University, Stanford, CA, USA
| | - Elsa Fouragnan
- School of Psychology, Faculty of Health, University of Plymouth, Plymouth, UK
| | - Til Ole Bergmann
- Neuroimaging Center, Focus Program Translational Neuroscience, Johannes Gutenberg University Medical Center, Mainz, Germany; Leibniz Institute for Resilience Research (LIR), Mainz, Germany.
| |
Collapse
|
6
|
Krokhmal A, Simcock IC, Treeby BE, Martin E. A comparative study of experimental and simulated ultrasound beam propagation through cranial bones. Phys Med Biol 2025; 70:025007. [PMID: 39700626 PMCID: PMC11734220 DOI: 10.1088/1361-6560/ada19d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2024] [Revised: 12/02/2024] [Accepted: 12/19/2024] [Indexed: 12/21/2024]
Abstract
Objective.Transcranial ultrasound is used in a variety of treatments, including neuromodulation, opening the blood-brain barrier, and high intensity focused ultrasound therapies. To ensure safety and efficacy of these treatments, numerical simulations of the ultrasound field within the brain are used for treatment planning and evaluation. This study investigates the accuracy of numerical modelling of the propagation of focused ultrasound through cranial bones.Approach.Holograms of acoustic fields after propagation through four human skull specimens were measured for frequencies ranging from 270 kHz to 1 MHz, using both quasi-continuous and pulsed modes. The open-source k-Wave toolbox was employed for simulations, using an equivalent-source hologram and a uniform bowl source with parameters that best matched the measured free-field pressure distribution.Main results.The average absolute error in k-Wave simulations with sound speed and density derived from CT scans compared to measurements was 15% for the spatial-peak acoustic pressure amplitude, 2.7 mm for the position of the focus, and 35% for the focal volume. Optimised uniform bowl sources achieved calculation accuracy comparable to that of the hologram sources.Significance.This method is demonstrated as a suitable tool for prediction of focal position, size and overall distribution of transcranial ultrasound fields. The accuracy of the shape and position of the focal region demonstrate the suitability of the sound speed and density mapping used here. However, large errors in pressure amplitude and transmission loss in some individual cases show that alternative methods for mapping individual skull attenuation are needed and the possibility of considerable errors in pressure amplitude should be taken into account when planning focused ultrasound studies or interventions in the human brain, and appropriate safety margins should be used.
Collapse
Affiliation(s)
- Alisa Krokhmal
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
| | - Ian C Simcock
- Great Ormond Street Hospital for Children NHS Foundation Trust, Great Ormond Street, London WC1N 3JH, United Kingdom
- UCL Great Ormond Street Institute of Child Health, 30 Guildford Street, London WC1N 3EH, United Kingdom
- NIHR Great Ormond Street Hospital Biomedical Research Centre, 30 Guildford Street, London WC1N 3EH, United Kingdom
| | - Bradley E Treeby
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
| | - Eleanor Martin
- Department of Medical Physics and Biomedical Engineering, University College London, London WC1E 6BT, United Kingdom
- Wellcome/EPSRC Centre for Interventional and Surgical Sciences, University College London, London WC1E 6BT, United Kingdom
| |
Collapse
|
7
|
Li Y, Wang X, Guo J, Wang Y, Zykov V, Bodenschatz E, Gao X. Sonogenetics is a novel antiarrhythmic mechanism. CHAOS (WOODBURY, N.Y.) 2025; 35:013127. [PMID: 39792701 DOI: 10.1063/5.0224817] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/21/2024] [Accepted: 12/01/2024] [Indexed: 01/12/2025]
Abstract
Arrhythmia of the heart is a dangerous and potentially fatal condition. The current widely used treatment is the implantable cardioverter defibrillator (ICD), but it is invasive and affects the patient's quality of life. The sonogenetic mechanism proposed here focuses ultrasound on a cardiac tissue, controls endogenous stretch-activated Piezo1 ion channels on the focal region's cardiomyocyte sarcolemma, and restores normal heart rhythm. In contrast to anchoring the implanted ICD lead at a fixed position in the myocardium, the size and position of the ultrasound focal region can be selected dynamically by adjusting the signals of every piezoelectric chip on the ultrasonic phased array, and it allows novel and efficient defibrillations. Based on the developed interdisciplinary electro-mechanical model of sonogenetic treatment, our analysis shows that the proposed ultrasound intensity and frequency will be safe and painless for humans and well below the limits established by the U.S. Food and Drug Administration.
Collapse
Affiliation(s)
- Yang Li
- School of Science, Beijing University of Posts and Telecommunications, Beijing 100876, China
- School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, China
| | - Xingang Wang
- School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, China
| | - Jianzhong Guo
- School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, China
| | - Yong Wang
- Laboratory for Fluid Physics, Pattern Formation and Biocomplexity, Max Planck Institute for Dynamics and Self-Organization, Göttingen 37077, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen 37077, Germany
| | - Vladimir Zykov
- Laboratory for Fluid Physics, Pattern Formation and Biocomplexity, Max Planck Institute for Dynamics and Self-Organization, Göttingen 37077, Germany
| | - Eberhard Bodenschatz
- Laboratory for Fluid Physics, Pattern Formation and Biocomplexity, Max Planck Institute for Dynamics and Self-Organization, Göttingen 37077, Germany
- DZHK (German Center for Cardiovascular Research), Partner Site Göttingen, Göttingen 37077, Germany
- Institute for Dynamics of Complex Systems, University of Göttingen, Göttingen 37075, Germany
- Laboratory of Atomic and Solid-State Physics and Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, New York 14853, USA
| | - Xiang Gao
- School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710062, China
- Laboratory for Fluid Physics, Pattern Formation and Biocomplexity, Max Planck Institute for Dynamics and Self-Organization, Göttingen 37077, Germany
| |
Collapse
|
8
|
Martin D, Xu R, Dressler M, O'Reilly MA. Ex vivovalidation of non-invasive phase correction for transspine focused ultrasound: model performance and target feasibility. Phys Med Biol 2024; 69:235001. [PMID: 39509818 DOI: 10.1088/1361-6560/ad8fed] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Accepted: 11/07/2024] [Indexed: 11/15/2024]
Abstract
Objective.To evaluate the feasibility of transspine focused ultrasound using simulation-based phase corrections from a CT-derived ray acoustics model.Approach.Bilateral transspine focusing was performed inex vivohuman vertebrae with a spine-specific ultrasound array. Ray acoustics-derived phase correction was compared to geometric focusing and a hydrophone-corrected gold standard. Planar hydrophone scans were recorded in the spinal canal and three metrics were calculated: target pressure, coronal and sagittal focal shift, and coronal and sagittal Sørensen-Dice similarity to the free-field.Post hocanalysis was performedin silicoto assess the impact of windows between vertebrae on focal shift.Main results.Hydrophone correction reduced mean sagittal plane shift from 1.74 ± 0.82 mm to 1.40 ± 0.82 mm and mean coronal plane shift from 1.07 ± 0.63 mm to 0.54 ± 0.49 mm. Ray acoustics correction reduced mean sagittal plane and coronal plane shift to 1.63 ± 0.83 mm and 0.83 ± 0.60 mm, respectively. Hydrophone correction increased mean sagittal similarity from 0.48 ± 0.22 to 0.68 ± 0.19 and mean coronal similarity from 0.48 ± 0.23 to 0.70 ± 0.19. Ray acoustics correction increased mean sagittal and coronal similarity to 0.53 ± 0.25 and 0.55 ± 0.26, respectively. Target pressure was relatively unchanged across beamforming methods.In silicoanalysis found that, for some targets, unoccluded paths may have increased focal shift.Significance. Gold standard phase correction significantly reduced coronal shift and significantly increased sagittal and coronal Sørensen-Dice similarity (p< 0.05). Ray acoustics-derived phase correction reduced sagittal and coronal shift and increased sagittal and coronal similarity but did not achieve statistical significance. Across beamforming methods, mean focal shift was comparable to MRI resolution, suggesting that transspine focusing is possible with minimal correction in favourable targets. Future work will explore the mitigation of acoustic windows with anti-focus control points.
Collapse
Affiliation(s)
- David Martin
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, ON M4N 3M5, Canada
- Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, 101 College Street Suite 15-701, Toronto, ON M5G 1L7, Canada
| | - Rui Xu
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, ON M4N 3M5, Canada
- Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, 101 College Street Suite 15-701, Toronto, ON M5G 1L7, Canada
| | - Max Dressler
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, ON M4N 3M5, Canada
| | - Meaghan A O'Reilly
- Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, 2075 Bayview Avenue, Toronto, ON M4N 3M5, Canada
- Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, 101 College Street Suite 15-701, Toronto, ON M5G 1L7, Canada
| |
Collapse
|
9
|
Jimenez-Gambin S, Bae S, Ji R, Tsitsos F, Konofagou EE. Feasibility of Hologram-Assisted Bilateral Blood-Brain Barrier Opening in Non-Human Primates. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2024; 71:1172-1185. [PMID: 39196737 PMCID: PMC11656487 DOI: 10.1109/tuffc.2024.3451289] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/30/2024]
Abstract
Focused ultrasound (FUS) and microbubbles facilitate blood-brain barrier opening (BBBO) noninvasively, transiently, and safely for targeted drug delivery. Unlike state-of-the-art approaches, in this study, we demonstrate for the first time the simultaneous, bilateral BBBO in non-human primates (NHPs) using acoustic holograms at caudate and putamen structures. The simple and low-cost system with a single-element FUS transducer and 3-D printed acoustic hologram was guided by neuronavigation and a robotic arm. The advantages of holograms are transcranial aberration correction, simultaneous multifocus and high localization, and target-independent transducer positioning, defining a promising alternative for time- and cost-efficient FUS procedures. Holograms were designed with the k-space method by time-reversal techniques. T1-weighted MRI was used for treatment planning, while the computed tomography (CT) scan provided the head tissues acoustic properties. For the BBBO procedure, a robotic arm allowed transducer positioning errors below 0.1 mm and 0.1°. Following positioning, 0.5-0.6-MPa, 513-kHz microbubble-enhanced FUS was applied for 4 min. For BBBO assessment, Post-FUS T1-weighted MRI was acquired, and contrast enhancement indicated bilateral gadolinium extravasation at both caudate or putamen structures. The two BBBO locations were separated by 13.13 mm with a volume of 91.81 mm3 in the caudate, compared with 9.40 mm with a volume of 124.52 mm3 in simulation, while they were separated by 21.74 mm with a volume of 145.38 mm3 in the putamen and compared with 22.32 mm with a volume of 156.42 mm3 in simulation. No neurological damage was observed through T2-weighted and susceptibility-weighted imaging. This study demonstrates the feasibility and safety of hologram-assisted neuronavigation-guided-FUS for BBBO in NHP, providing thus an avenue for clinical translation.
Collapse
|
10
|
O'Reilly MA. Exploiting the mechanical effects of ultrasound for noninvasive therapy. Science 2024; 385:eadp7206. [PMID: 39265013 DOI: 10.1126/science.adp7206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2024] [Accepted: 08/07/2024] [Indexed: 09/14/2024]
Abstract
Focused ultrasound is a platform technology capable of eliciting a wide range of biological responses with high spatial precision deep within the body. Although focused ultrasound is already in clinical use for focal thermal ablation of tissue, there has been a recent growth in development and translation of ultrasound-mediated nonthermal therapies. These approaches exploit the physical forces of ultrasound to produce a range of biological responses dependent on exposure conditions. This review discusses recent advances in four application areas that have seen particular growth and have immense clinical potential: brain drug delivery, neuromodulation, focal tissue destruction, and endogenous immune system activation. Owing to the maturation of transcranial ultrasound technology, the brain is a major target organ; however, clinical indications outside the brain are also discussed.
Collapse
Affiliation(s)
- Meaghan A O'Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, ON, Canada
- Department of Medical Biophysics, Temerty Faculty of Medicine, University of Toronto, Toronto, ON, Canada
| |
Collapse
|
11
|
Lafond M, Payne A, Lafon C. Therapeutic ultrasound transducer technology and monitoring techniques: a review with clinical examples. Int J Hyperthermia 2024; 41:2389288. [PMID: 39134055 PMCID: PMC11375802 DOI: 10.1080/02656736.2024.2389288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 07/02/2024] [Accepted: 08/01/2024] [Indexed: 09/07/2024] Open
Abstract
The exponential growth of therapeutic ultrasound applications demonstrates the power of the technology to leverage the combinations of transducer technology and treatment monitoring techniques to effectively control the preferred bioeffect to elicit the desired clinical effect.Objective: This review provides an overview of the most commonly used bioeffects in therapeutic ultrasound and describes existing transducer technologies and monitoring techniques to ensure treatment safety and efficacy.Methods and materials: Literature reviews were conducted to identify key choices that essential in terms of transducer design, treatment parameters and procedure monitoring for therapeutic ultrasound applications. Effective combinations of these options are illustrated through descriptions of several clinical indications, including uterine fibroids, prostate disease, liver cancer, and brain cancer, that have been successful in leveraging therapeutic ultrasound to provide effective patient treatments.Results: Despite technological constraints, there are multiple ways to achieve a desired bioeffect with therapeutic ultrasound in a target tissue. Visualizations of the interplay of monitoring modality, bioeffect, and applied acoustic parameters are presented that demonstrate the interconnectedness of the field of therapeutic ultrasound. While the clinical indications explored in this review are at different points in the clinical evaluation path, based on the ever expanding research being conducted in preclinical realms, it is clear that additional clinical applications of therapeutic ultrasound that utilize a myriad of bioeffects will continue to grow and improve in the coming years.Conclusions: Therapeutic ultrasound will continue to improve in the next decades as the combination of transducer technology and treatment monitoring techniques will continue to evolve and be translated in clinical settings, leading to more personalized and efficient therapeutic ultrasound mediated therapies.
Collapse
Affiliation(s)
- Maxime Lafond
- LabTAU, INSERM, Centre Léon Bérard, Université, Lyon, France
| | - Allison Payne
- Department of Radiology and Imaging Sciences, University of UT, Salt Lake City, UT, USA
| | - Cyril Lafon
- LabTAU, INSERM, Centre Léon Bérard, Université, Lyon, France
| |
Collapse
|
12
|
Chesney KM, Keating GF, Patel N, Kilburn L, Fonseca A, Wu CC, Nazarian J, Packer RJ, Donoho DA, Oluigbo C, Myseros JS, Keating RF, Syed HR. The role of focused ultrasound for pediatric brain tumors: current insights and future implications on treatment strategies. Childs Nerv Syst 2024; 40:2333-2344. [PMID: 38702518 DOI: 10.1007/s00381-024-06413-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/10/2024] [Accepted: 04/14/2024] [Indexed: 05/06/2024]
Abstract
INTRODUCTION Focused ultrasound (FUS) is an innovative and emerging technology for the treatment of adult and pediatric brain tumors and illustrates the intersection of various specialized fields, including neurosurgery, neuro-oncology, radiation oncology, and biomedical engineering. OBJECTIVE The authors provide a comprehensive overview of the application and implications of FUS in treating pediatric brain tumors, with a special focus on pediatric low-grade gliomas (pLGGs) and the evolving landscape of this technology and its clinical utility. METHODS The fundamental principles of FUS include its ability to induce thermal ablation or enhance drug delivery through transient blood-brain barrier (BBB) disruption, emphasizing the adaptability of high-intensity focused ultrasound (HIFU) and low-intensity focused ultrasound (LIFU) applications. RESULTS Several ongoing clinical trials explore the potential of FUS in offering alternative therapeutic strategies for pathologies where conventional treatments fall short, specifically centrally-located benign CNS tumors and diffuse intrinsic pontine glioma (DIPG). A case illustration involving the use of HIFU for pilocytic astrocytoma is presented. CONCLUSION Discussions regarding future applications of FUS for the treatment of gliomas include improved drug delivery, immunomodulation, radiosensitization, and other technological advancements.
Collapse
Affiliation(s)
- Kelsi M Chesney
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA
- Department of Neurosurgery, MedStar Georgetown University Hospital, Washington, DC, USA
| | - Gregory F Keating
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA
- Department of Neurosurgery, MedStar Georgetown University Hospital, Washington, DC, USA
| | - Nirali Patel
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA
- Department of Neurosurgery, MedStar Georgetown University Hospital, Washington, DC, USA
| | - Lindsay Kilburn
- Brain Tumor Institute, Children's National Hospital, Washington, DC, USA
| | - Adriana Fonseca
- Brain Tumor Institute, Children's National Hospital, Washington, DC, USA
| | - Cheng-Chia Wu
- Department of Radiation Oncology, Columbia University Irving Medical Center, New York, NY, USA
| | - Javad Nazarian
- Brain Tumor Institute, Children's National Hospital, Washington, DC, USA
| | - Roger J Packer
- Brain Tumor Institute, Children's National Hospital, Washington, DC, USA
| | - Daniel A Donoho
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA
- Department of Neurosurgery, George Washington University School of Medicine & Health Sciences, Washington, DC, USA
| | - Chima Oluigbo
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA
- Department of Neurosurgery, George Washington University School of Medicine & Health Sciences, Washington, DC, USA
| | - John S Myseros
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA
- Department of Neurosurgery, George Washington University School of Medicine & Health Sciences, Washington, DC, USA
| | - Robert F Keating
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA
- Department of Neurosurgery, George Washington University School of Medicine & Health Sciences, Washington, DC, USA
| | - Hasan R Syed
- Department of Neurosurgery, Children's National Hospital, Washington, DC, USA.
- Department of Neurosurgery, George Washington University School of Medicine & Health Sciences, Washington, DC, USA.
| |
Collapse
|
13
|
Antoniou A, Evripidou N, Damianou C. Focused ultrasound heating in brain tissue/skull phantoms with 1 MHz single-element transducer. J Ultrasound 2024; 27:263-274. [PMID: 37517052 PMCID: PMC11178743 DOI: 10.1007/s40477-023-00810-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 07/09/2023] [Indexed: 08/01/2023] Open
Abstract
PURPOSE The study aims to provide insights on the practicality of using single-element transducers for transcranial Focused Ultrasound (tFUS) thermal applications. METHODS FUS sonications were performed through skull phantoms embedding agar-based tissue mimicking gels using a 1 MHz single-element spherically focused transducer. The skull phantoms were 3D printed with Acrylonitrile Butadiene Styrene (ABS) and Resin thermoplastics having the exact skull bone geometry of a healthy volunteer. The temperature field distribution during and after heating was monitored in a 3 T Magnetic Resonance Imaging (MRI) scanner using MR thermometry. The effect of the skull's thickness on intracranial heating was investigated. RESULTS A single FUS sonication at focal acoustic intensities close to 1580 W/cm2 for 60 s in free field heated up the agar phantom to ablative temperatures reaching about 90 °C (baseline of 37 °C). The ABS skull strongly blocked the ultrasonic waves, resulting in zero temperature increase within the phantom. Considerable heating was achieved through the Resin skull, but it remained at hyperthermia levels. Conversely, tFUS through a 1 mm Resin skull showed enhanced ultrasonic penetration and heating, with the focal temperature reaching 70 °C. CONCLUSIONS The ABS skull demonstrated poorer performance in terms of tFUS compared to the Resin skull owing to its higher ultrasonic attenuation and porosity. The thin Resin phantom of 1 mm thickness provided an efficient acoustic window for delivering tFUS and heating up deep phantom areas. The results of such studies could be particularly useful for accelerating the establishment of a wider range of tFUS applications.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, 30 Archbishop Kyprianou Street, 3036, Limassol, Cyprus.
| |
Collapse
|
14
|
Bancel T, Béranger B, Daniel M, Didier M, Santin M, Rachmilevitch I, Shapira Y, Tanter M, Bardinet E, Fernandez Vidal S, Attali D, Galléa C, Dizeux A, Vidailhet M, Lehéricy S, Grabli D, Pyatigorskaya N, Karachi C, Hainque E, Aubry JF. Sustained reduction of essential tremor with low-power non-thermal transcranial focused ultrasound stimulations in humans. Brain Stimul 2024; 17:636-647. [PMID: 38734066 DOI: 10.1016/j.brs.2024.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 05/03/2024] [Accepted: 05/03/2024] [Indexed: 05/13/2024] Open
Abstract
BACKGROUND Transcranial ultrasound stimulation (TUS) is a non-invasive brain stimulation technique; when skull aberrations are compensated for, this technique allows, with millimetric accuracy, circumvention of the invasive surgical procedure associated with deep brain stimulation (DBS) and the limited spatial specificity of transcranial magnetic stimulation. OBJECTIVE /hypothesis: We hypothesize that MR-guided low-power TUS can induce a sustained decrease of tremor power in patients suffering from medically refractive essential tremor. METHODS The dominant hand only was targeted, and two anatomical sites were sonicated in this exploratory study: the ventral intermediate nucleus of the thalamus (VIM) and the dentato-rubro-thalamic tract (DRT). Patients (N = 9) were equipped with MR-compatible accelerometers attached to their hands to monitor their tremor in real-time during TUS. RESULTS VIM neurostimulations followed by a low-duty cycle (5 %) DRT stimulation induced a substantial decrease in the tremor power in four patients, with a minimum of 89.9 % reduction when compared with the baseline power a few minutes after the DRT stimulation. The only patient stimulated in the VIM only and with a low duty cycle (5 %) also experienced a sustained reduction of the tremor (up to 93.4 %). Four patients (N = 4) did not respond. The temperature at target was 37.2 ± 1.4 °C compared to 36.8 ± 1.4 °C for a 3 cm away control point. CONCLUSIONS MR-guided low power TUS can induce a substantial and sustained decrease of tremor power. Follow-up studies need to be conducted to reproduce the effect and better to understand the variability of the response amongst patients. MR thermometry during neurostimulations showed no significant thermal rise, supporting a mechanical effect.
Collapse
Affiliation(s)
- Thomas Bancel
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR 8063, PSL University, Paris, France
| | - Benoît Béranger
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France
| | - Maxime Daniel
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR 8063, PSL University, Paris, France
| | - Mélanie Didier
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France
| | - Mathieu Santin
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France
| | | | | | - Mickael Tanter
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR 8063, PSL University, Paris, France
| | - Eric Bardinet
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France
| | - Sara Fernandez Vidal
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France
| | - David Attali
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR 8063, PSL University, Paris, France; Université Paris Cité, GHU-Paris Psychiatrie et Neurosciences, Hôpital Sainte Anne, F-75014, Paris, France
| | - Cécile Galléa
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France
| | - Alexandre Dizeux
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR 8063, PSL University, Paris, France
| | - Marie Vidailhet
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France; Department of Neurology, Hôpital de la Pitié Salpêtrière, Sorbonne Université, AP-HP, Paris, France
| | - Stéphane Lehéricy
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France; Department of Neuroradiology, Hôpital de la Pitié Salpêtrière, Sorbonne Université, AP-HP, Paris, France
| | - David Grabli
- Department of Neurology, Hôpital de la Pitié Salpêtrière, Sorbonne Université, AP-HP, Paris, France
| | - Nadya Pyatigorskaya
- ICM-Paris Brain Institute, Centre de NeuroImagerie de Recherche-CENIR, Inserm U 1127, CNRS UMR 7225, Sorbonne Université, F-75013, Paris, France; Department of Neuroradiology, Hôpital de la Pitié Salpêtrière, Sorbonne Université, AP-HP, Paris, France
| | - Carine Karachi
- Department of Neurosurgery, Hôpital de la Pitié Salpêtrière, Sorbonne Université, AP-HP, Paris, France
| | - Elodie Hainque
- Department of Neurology, Hôpital de la Pitié Salpêtrière, Sorbonne Université, AP-HP, Paris, France
| | - Jean-François Aubry
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR 8063, PSL University, Paris, France.
| |
Collapse
|
15
|
Xu R, Treeby BE, Martin E. Safety Review of Therapeutic Ultrasound for Spinal Cord Neuromodulation and Blood-Spinal Cord Barrier Opening. ULTRASOUND IN MEDICINE & BIOLOGY 2024; 50:317-331. [PMID: 38182491 DOI: 10.1016/j.ultrasmedbio.2023.11.007] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2023] [Revised: 11/07/2023] [Accepted: 11/10/2023] [Indexed: 01/07/2024]
Abstract
New focused ultrasound spinal cord applications have emerged, particularly those improving therapeutic agent delivery to the spinal cord via blood-spinal cord barrier opening and the neuromodulation of spinal cord tracts. One hurdle in the development of these applications is safety. It may be possible to use safety trends from seminal and subsequent works in focused ultrasound to guide the development of safety guidelines for spinal cord applications. We collated data from decades of pre-clinical studies and illustrate a clear relationship between damage, time-averaged spatial peak intensity and exposure duration. This relationship suggests a thermal mechanism underlies ultrasound-induced spinal cord damage. We developed minimum and mean thresholds for damage from these pre-clinical studies. When these thresholds were plotted against the parameters used in recent pre-clinical ultrasonic spinal cord neuromodulation studies, the majority of the neuromodulation studies were near or above the minimum threshold. This suggests that a thermal neuromodulatory effect may exist for ultrasonic spinal cord neuromodulation, and that the thermal dose must be carefully controlled to avoid damage to the spinal cord. By contrast, the intensity-exposure duration threshold had no predictive value when applied to blood-spinal cord barrier opening studies that employed injected contrast agents. Most blood-spinal cord barrier opening studies observed slight to severe damage, except for small animal studies that employed an active feedback control method to limit pressures based on measured bubble oscillation behavior. The development of new focused ultrasound spinal cord applications perhaps reflects the recent success in the development of focused ultrasound brain applications, and recent work has begun on the translation of these technologies from brain to spinal cord. However, a great deal of work remains to be done, particularly with respect to developing and accepting safety standards for these applications.
Collapse
Affiliation(s)
- Rui Xu
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK.
| | - Bradley E Treeby
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| | - Eleanor Martin
- Department of Medical Physics and Biomedical Engineering, University College London, London, UK
| |
Collapse
|
16
|
Reinhardt N, Schmitz C, Milz S, de la Fuente M. Influence of the skull bone and brain tissue on the sound field in transcranial extracorporeal shock wave therapy: an ex vivo study. BIOMED ENG-BIOMED TE 2024; 69:27-37. [PMID: 37732512 DOI: 10.1515/bmt-2022-0332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 08/21/2023] [Indexed: 09/22/2023]
Abstract
OBJECTIVES Focused ultrasound is mainly known for focal ablation and localized hyperthermia of tissue. During the last decade new treatment options were developed for neurological indications based on blood-brain-barrier opening or neuromodulation. Recently, the transcranial application of shock waves has been a subject of research. However, the mechanisms of action are not yet understood. Hence, it is necessary to know the energy that reaches the brain during the treatment and the focusing characteristics within the tissue. METHODS The sound field of a therapeutic extracorporeal shock wave transducer was investigated after passing human skull bone (n=5) or skull bone with brain tissue (n=2) in this ex vivo study. The maximum and minimum pressure distribution and the focal pressure curves were measured at different intensity levels and penetration depths, and compared to measurements in water. RESULTS Mean peak negative pressures of up to -4.97 MPa were reached behind the brain tissue. The positive peak pressure was attenuated by between 20.85 and 25.38 dB/cm by the skull bone. Additional damping by the brain tissue corresponded to between 0.29 and 0.83 dB/cm. Compared to the measurements in water, the pulse intensity integral in the focal spot was reduced by 84 % by the skull bone and by additional 2 % due to the brain tissue, resulting in a total damping of up to 86 %. The focal position was shifted up to 8 mm, whereas the basic shape of the pressure curves was preserved. CONCLUSIONS Positive effects may be stimulated by transcranial shock wave therapy but damage cannot be excluded.
Collapse
Affiliation(s)
- Nina Reinhardt
- Chair of Medical Engineering, RWTH Aachen University, Aachen, Germany
| | - Christoph Schmitz
- Chair of Neuroanatomy, Institute of Anatomy, Faculty of Medicine, LMU Munich, Munich, Germany
| | - Stefan Milz
- Chair of Neuroanatomy, Institute of Anatomy, Faculty of Medicine, LMU Munich, Munich, Germany
| | | |
Collapse
|
17
|
Antoniou A, Damianou C. Feasibility of Ultrasonic Heating through Skull Phantom Using Single-element Transducer. J Med Ultrasound 2024; 32:32-40. [PMID: 38665339 PMCID: PMC11040484 DOI: 10.4103/jmu.jmu_3_23] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2023] [Revised: 03/14/2023] [Accepted: 03/31/2023] [Indexed: 04/28/2024] Open
Abstract
BACKGROUND Noninvasive neurosurgery has become possible through the use of transcranial focused ultrasound (FUS). This study assessed the heating ability of single element spherically focused transducers operating at 0.4 and 1.1 MHz through three-dimensional (3D) printed thermoplastic skull phantoms. METHODS Phantoms with precise skull bone geometry of a male patient were 3D printed using common thermoplastic materials following segmentation on a computed tomography head scan image. The brain tissue was mimicked by an agar-based gel phantom developed in-house. The selection of phantom materials was mainly based on transmission-through attenuation measurements. Phantom sonications were performed through water, and then, with the skull phantoms intervening the beam path. In each case, thermometry was performed at the focal spot using thermocouples. RESULTS The focal temperature change in the presence of the skull phantoms was reduced to less than 20 % of that recorded in free field when using the 0.4 MHz transducer, whereas the 1.1 MHz trans-skull sonication produced minimal or no change in focal temperature. The 0.4 MHz transducer showed better performance in trans-skull transmission but still not efficient. CONCLUSION The inability of both tested single element transducers to steer the beam through the high attenuating skull phantoms and raise the temperature at the focus was confirmed, underlying the necessity to use a correction technique to compensate for energy losses, such those provided by phased arrays. The proposed phantom could be used as a cost-effective and ergonomic tool for trans-skull FUS preclinical studies.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering and Informatics, Cyprus University of Technology, Limassol, Cyprus
| |
Collapse
|
18
|
Kim J, Kasoji S, Durham PG, Dayton PA. Nanoparticle-Epoxy Composite Molding for Undeformed Acoustic Holograms With Tailored Acoustic Properties. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2023; 70:1554-1562. [PMID: 37561617 DOI: 10.1109/tuffc.2023.3303894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/12/2023]
Abstract
Acoustic hologram (AH) lenses are typically produced by high-resolution 3-D printing methods, such as stereolithography (SLA) printing. However, SLA printing of thin, plate-shaped lens structures has major limitations, including vulnerability to deformation during photocuring and limited control of acoustic impedance. To overcome these limitations, we demonstrated a nanoparticle-epoxy composite (NPEC) molding technique, and we tested its feasibility for AH lens fabrication. The characterized acoustic impedance of the 22.5% NPEC was 4.64 MRayl, which is 55% higher than the clear photopolymer (2.99 MRayl) used by SLA. Simulations demonstrated that the improved pressure transmission by the higher acoustic impedance of the NPEC resulted in 21% higher pressure amplitude in the region of interest (ROI, -6-dB pressure amplitude pixels) than the photopolymer. This improvement was experimentally demonstrated after prototyping NPEC lenses through a molding process. The NPEC lens showed no significant deformation and 72% lower thickness profile errors than the photopolymer, which otherwise experienced deformed edges due to thermal bending. Beam mapping results using the NPEC lens validated the predicted improvement, demonstrating 24% increased pressure amplitude on average and 10% improved structural similarity (SSIM) with the simulated pressure pattern compared to the photopolymer lens. This method can be used for AH lens applications with improved pressure output and accurate pressure field formation.
Collapse
|
19
|
Yoo SS, Kim E, Kowsari K, Van Reet J, Kim HC, Yoon K. Non-invasive enhancement of intracortical solute clearance using transcranial focused ultrasound. Sci Rep 2023; 13:12339. [PMID: 37524783 PMCID: PMC10390479 DOI: 10.1038/s41598-023-39640-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Accepted: 07/28/2023] [Indexed: 08/02/2023] Open
Abstract
Transport of interstitial fluid and solutes plays a critical role in clearing metabolic waste from the brain. Transcranial application of focused ultrasound (FUS) has been shown to promote localized cerebrospinal fluid solute uptake into the brain parenchyma; however, its effects on the transport and clearance of interstitial solutes remain unknown. We demonstrate that pulsed application of low-intensity FUS to the rat brain enhances the transport of intracortically injected fluorescent tracers (ovalbumin and high molecular-weight dextran), yielding greater parenchymal tracer volume distribution compared to the unsonicated control group (ovalbumin by 40.1% and dextran by 34.6%). Furthermore, FUS promoted the drainage of injected interstitial ovalbumin to both superficial and deep cervical lymph nodes (cLNs) ipsilateral to sonication, with 78.3% higher drainage observed in the superficial cLNs compared to the non-sonicated hemisphere. The application of FUS increased the level of solute transport visible from the dorsal brain surface, with ~ 43% greater area and ~ 19% higher fluorescence intensity than the unsonicated group, especially in the pial surface ipsilateral to sonication. The sonication did not elicit tissue-level neuronal excitation, measured by an electroencephalogram, nor did it alter the molecular weight of the tracers. These findings suggest that nonthermal transcranial FUS can enhance advective transport of interstitial solutes and their subsequent removal in a completely non-invasive fashion, offering its potential non-pharmacological utility in facilitating clearance of waste from the brain.
Collapse
Affiliation(s)
- Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA.
| | - Evgenii Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
| | - Kavin Kowsari
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
| | - Jared Van Reet
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
| | - Hyun-Chul Kim
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, MA, 02115, Boston, USA
- Department of Artificial Intelligence, Kyungpook National University, Daegu, Republic of Korea
| | - Kyungho Yoon
- School of Computational Science and Engineering, Yonsei University, Seoul, Republic of Korea
| |
Collapse
|
20
|
Hughes A, Khan DS, Alkins R. Current and Emerging Systems for Focused Ultrasound-Mediated Blood-Brain Barrier Opening. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1479-1490. [PMID: 37100672 DOI: 10.1016/j.ultrasmedbio.2023.02.017] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Revised: 02/09/2023] [Accepted: 02/23/2023] [Indexed: 05/17/2023]
Abstract
With an ever-growing list of neurological applications of focused ultrasound (FUS), there has been a consequent increase in the variety of systems for delivering ultrasound energy to the brain. Specifically, recent successful pilot clinical trials of blood-brain barrier (BBB) opening with FUS have generated substantial interest in the future applications of this relatively novel therapy, with divergent, purpose-built technologies emerging. With many of these technologies at various stages of pre-clinical and clinical investigation, this article seeks to provide an overview and analysis of the numerous medical devices in active use and under development for FUS-mediated BBB opening.
Collapse
Affiliation(s)
- Alec Hughes
- School of Medicine, Faculty of Health Sciences, Queen's University, Kingston, ON, Canada
| | - Dure S Khan
- Centre for Neuroscience Studies, Queen's University, Kingston, ON, Canada
| | - Ryan Alkins
- Centre for Neuroscience Studies, Queen's University, Kingston, ON, Canada; Division of Neurosurgery, Department of Surgery, Kingston Health Sciences Centre, Queen's University, Kingston, ON, Canada.
| |
Collapse
|
21
|
Brinker ST, Yoon K, Benveniste H. Global sonication of the human intracranial space via a jumbo planar transducer. ULTRASONICS 2023; 134:107062. [PMID: 37343366 DOI: 10.1016/j.ultras.2023.107062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 05/25/2023] [Accepted: 05/30/2023] [Indexed: 06/23/2023]
Abstract
Contrary to conditioning a Focused Ultrasound (FUS) beam to sonicate a localized region of the human brain, the goal of this investigation was to explore the prospect of distributing homogeneous ultrasound energy over the entire brain space with a large cranium-wide ultrasound beam. Recent ultrasound preclincal studies utilizing large or whole brain stimulation regions create a demand for expanding the treatment envelope of transcranial pulsed-low intensity ultrasound towards Global Brain Sonication (GBS) for potential human investigation. Here, we conduct ultrasound field characterizations when transmitting pulsed ultrasound through human skull specimens using a 1-3 piezocomposite planar transducer operating at 464 kHz with an active single-element surface of 30 × 30 cm. Through computational simulation and hydrophone scanning methodology, ultrasound wave behavior and dose homogeneity in the brain space were evaluated under various trajectories of sonication using the planar transducer. Clinically relevant pulse parameters used for transcranial therapeutic ultrasound applications were used in the experiments. Simulations and empirical testing revealed that dose homogeneity and acoustic intensity over the brain space are influenced by sonication trajectory, skull lens effects, and acoustic wave reflections. The transducer can emit a spatial peak pulse average intensity of 4.03 W/cm2 (0.24 MPa) measured in the free-field at 464 kHz with electrical power of 1 kW. The simulation showed that approximately 99 % of the cranial volume was exposed with <30 % of the maximum external acoustic intensity being transmitted into the skull. The transmission loss across all sonication trajectories is similar to previously reported FUS studies. A marker for GBS dose homogeneity is introduced to score the ultrasound pressure field uniformity in the intracranial space. Results of this study identify the initial challenges of exposing the entire human brain space with ultrasound using a large cranium-wide sonication beam intended for global brain therapeutic modulation.
Collapse
Affiliation(s)
- Spencer T Brinker
- Department of Anesthesiology, Yale School of Medicine, New Haven, CT, USA.
| | - Kyungho Yoon
- School of Mathematics and Computing (Computational Science and Engineering), Yonsei University, Seoul, South Korea
| | - Helene Benveniste
- Department of Anesthesiology, Yale School of Medicine, New Haven, CT, USA
| |
Collapse
|
22
|
Hong Park J, Lee S, Jeon H, Hoon Kim J, Jung Kim D, Im M, Chul Lee B. A novel convex acoustic lens-attached ultrasound drug delivery system and its testing in a murine melanoma subcutaneous modelo. Int J Pharm 2023:123118. [PMID: 37302671 DOI: 10.1016/j.ijpharm.2023.123118] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 05/18/2023] [Accepted: 06/06/2023] [Indexed: 06/13/2023]
Abstract
Target-specific drug release is indispensable to improve chemotherapeutic efficacy as it enhances drug uptake and penetration into tumors. Sono-responsive drug-loaded nano-/micro-particles are a promising solution for achieving target specificity by exposing them to ultrasound near tumors. However, the complicated synthetic processes and limited ultrasound (US) exposure conditions, such as limited control of ultrasound focal depth and acoustic power, prevent the practical application of this approach in clinical practice. Here, we propose a convex acoustic lens-attached US (CALUS) as a simple, economic, and efficient alternative of focused US for drug delivery system (DDS) application. The CALUS was characterized both numerically and experimentally using a hydrophone. In vitro, microbubbles (MBs) inside microfluidic channels were destroyed using the CALUS with various acoustic parameters (acoustic pressure [P], pulse repetition frequency [PRF], and duty cycle) and flow velocity. In vivo, tumor inhibition was evaluated using melanoma-bearing mice by characterizing tumor growth rate, animal weight, and intratumoral drug concentration with/without CALUS DDS. US beams were measured to be efficiently converged by CALUS, which was consistent with our simulation results. The acoustic parameters were optimized through the CALUS-induced MB destruction test (P = 2.34 MPa, PRF = 100 kHz, and duty cycle = 9%); this optimal parameter combination successfully induced MB destruction inside the microfluidic channel with an average flow velocity of up to 9.6 cm/s. The CALUS also enhanced the therapeutic effects of an antitumor drug (doxorubicin) in vivo in a murine melanoma model. The combination of the doxorubicin and the CALUS inhibited tumor growth by ∼55% more than doxorubicin alone, clearly indicating synergistic antitumor efficacy. Our tumor growth inhibition performance was better than other methods based on drug carriers, even without a time-consuming and complicated chemical synthesis process. This result suggests that our novel, simple, economic, and efficient target-specific DDS may offer a transition from preclinical research to clinical trials and a potential treatment approach for patient-centered healthcare.
Collapse
Affiliation(s)
- Jun Hong Park
- Bionics Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Seunghyun Lee
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Republic of Korea; Department of Radiology, Seoul National University College of Medicine, Seoul 03080, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea
| | - Hoyoon Jeon
- Bionics Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea
| | - Jung Hoon Kim
- Department of Radiology, Seoul National University Hospital, Seoul 03080, Republic of Korea; Department of Radiology, Seoul National University College of Medicine, Seoul 03080, Republic of Korea; Institute of Radiation Medicine, Seoul National University Medical Research Center, Seoul 03080, Republic of Korea
| | - Da Jung Kim
- Metabolomics Core Facility, Department of Transdisciplinary Research and Collaboration, Biomedical Research Institute, Seoul National University Hospital, Seoul 03080, Republic of Korea
| | - Maesoon Im
- Brain Science Institute, KIST, Seoul 02792, Republic of Korea; Division of Bio-Medical Science & Technology, KIST School, University of Science & Technology (UST), Seoul 02792, Republic of Korea
| | - Byung Chul Lee
- Bionics Research Center, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea; Division of Bio-Medical Science & Technology, KIST School, University of Science & Technology (UST), Seoul 02792, Republic of Korea; KHU-KIST Department of Converging Science and Technology, Kyung Hee University, Seoul 02447, Republic of Korea.
| |
Collapse
|
23
|
Xu L, Pacia CP, Gong Y, Hu Z, Chien CY, Yang L, Gach HM, Hao Y, Comron H, Huang J, Leuthardt EC, Chen H. Characterization of the Targeting Accuracy of a Neuronavigation-Guided Transcranial FUS System In Vitro, In Vivo, and In Silico. IEEE Trans Biomed Eng 2023; 70:1528-1538. [PMID: 36374883 PMCID: PMC10176741 DOI: 10.1109/tbme.2022.3221887] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Focused ultrasound (FUS)-enabled liquid biopsy (sonobiopsy) is an emerging technique for the noninvasive and spatiotemporally controlled diagnosis of brain cancer by inducing blood-brain barrier (BBB) disruption to release brain tumor-specific biomarkers into the blood circulation. The feasibility, safety, and efficacy of sonobiopsy were demonstrated in both small and large animal models using magnetic resonance-guided FUS devices. However, the high cost and complex operation of magnetic resonance-guided FUS devices limit the future broad application of sonobiopsy in the clinic. In this study, a neuronavigation-guided sonobiopsy device is developed and its targeting accuracy is characterized in vitro, in vivo, and in silico. The sonobiopsy device integrated a commercially available neuronavigation system (BrainSight) with a nimble, lightweight FUS transducer. Its targeting accuracy was characterized in vitro in a water tank using a hydrophone. The performance of the device in BBB disruption was verified in vivo using a pig model, and the targeting accuracy was quantified by measuring the offset between the target and the actual locations of BBB opening. The feasibility of the FUS device in targeting glioblastoma (GBM) tumors was evaluated in silico using numerical simulation by the k-Wave toolbox in glioblastoma patients. It was found that the targeting accuracy of the neuronavigation-guided sonobiopsy device was 1.7 ± 0.8 mm as measured in the water tank. The neuronavigation-guided FUS device successfully induced BBB disruption in pigs with a targeting accuracy of 3.3 ± 1.4 mm. The targeting accuracy of the FUS transducer at the GBM tumor was 5.5 ± 4.9 mm. Age, sex, and incident locations were found to be not correlated with the targeting accuracy in GBM patients. This study demonstrated that the developed neuronavigation-guided FUS device could target the brain with a high spatial targeting accuracy, paving the foundation for its application in the clinic.
Collapse
|
24
|
Gattin M, Bochud N, Rosi G, Grossman Q, Ruffoni D, Naili S. Ultrasonic bandgaps in viscoelastic 1D-periodic media: Mechanical modeling and experimental validation. ULTRASONICS 2023; 131:106951. [PMID: 36796203 DOI: 10.1016/j.ultras.2023.106951] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Revised: 12/29/2022] [Accepted: 02/06/2023] [Indexed: 06/18/2023]
Abstract
Multi-material additive manufacturing is receiving increasing attention in the field of acoustics, in particular towards the design of micro-architectured periodic media used to achieve programmable ultrasonic responses. To unravel the effect of the material properties and spatial arrangement of the printed constituents, there is an unmet need in developing wave propagation models for prediction and optimization purposes. In this study, we propose to investigate the transmission of longitudinal ultrasound waves through 1D-periodic biphasic media, whose constituent materials are viscoelastic. To this end, Bloch-Floquet analysis is applied in the frame of viscoelasticity, with the aim of disentangling the relative contributions of viscoelasticity and periodicity on ultrasound signatures, such as dispersion, attenuation, and bandgaps localization. The impact of the finite size nature of these structures is then assessed by using a modeling approach based on the transfer matrix formalism. Finally, the modeling outcomes, i.e., frequency-dependent phase velocity and attenuation, are confronted with experiments conducted on 3D-printed samples, which exhibit a 1D periodicity at length-scales of a few hundreds of micrometers. Altogether, the obtained results shed light on the modeling characteristics to be considered when predicting the complex acoustic behavior of periodic media in the ultrasonic regime.
Collapse
Affiliation(s)
- Max Gattin
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010, Créteil, France
| | - Nicolas Bochud
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010, Créteil, France.
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010, Créteil, France
| | - Quentin Grossman
- Mechanics of Biological and Bioinspired Materials Laboratory, Department of Aerospace and Mechanical Engineering, University of Liège, Quartier Polytech 1, Allée de la Découverte, B-4000 Liège, Belgium
| | - Davide Ruffoni
- Mechanics of Biological and Bioinspired Materials Laboratory, Department of Aerospace and Mechanical Engineering, University of Liège, Quartier Polytech 1, Allée de la Découverte, B-4000 Liège, Belgium
| | - Salah Naili
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010, Créteil, France
| |
Collapse
|
25
|
Andrés D, Rivens I, Mouratidis P, Jiménez N, Camarena F, ter Haar G. Holographic Focused Ultrasound Hyperthermia System for Uniform Simultaneous Thermal Exposure of Multiple Tumor Spheroids. Cancers (Basel) 2023; 15:2540. [PMID: 37174005 PMCID: PMC10177503 DOI: 10.3390/cancers15092540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/23/2023] [Accepted: 04/26/2023] [Indexed: 05/15/2023] Open
Abstract
Hyperthermia is currently used to treat cancer due to its ability to radio- and chemo-sensitize and to stimulate the immune response. While ultrasound is non-ionizing and can induce hyperthermia deep within the body non-invasively, achieving uniform and volumetric hyperthermia is challenging. This work presents a novel focused ultrasound hyperthermia system based on 3D-printed acoustic holograms combined with a high-intensity focused ultrasound (HIFU) transducer to produce a uniform iso-thermal dose in multiple targets. The system is designed with the aim of treating several 3D cell aggregates contained in an International Electrotechnical Commission (IEC) tissue-mimicking phantom with multiple wells, each holding a single tumor spheroid, with real-time temperature and thermal dose monitoring. System performance was validated using acoustic and thermal methods, ultimately yielding thermal doses in three wells that differed by less than 4%. The system was tested in vitro for delivery of thermal doses of 0-120 cumulative equivalent minutes at 43 °C (CEM43) to spheroids of U87-MG glioma cells. The effects of ultrasound-induced heating on the growth of these spheroids were compared with heating using a polymerase chain reaction (PCR) thermocycler. Results showed that exposing U87-MG spheroids to an ultrasound-induced thermal dose of 120 CEM43 shrank them by 15% and decreased their growth and metabolic activity more than seen in those exposed to a thermocycler-induced heating. This low-cost approach of modifying a HIFU transducer to deliver ultrasound hyperthermia opens new avenues for accurately controlling thermal dose delivery to complex therapeutic targets using tailored acoustic holograms. Spheroid data show that thermal and non-thermal mechanisms are implicated in the response of cancer cells to non-ablative ultrasound heating.
Collapse
Affiliation(s)
- Diana Andrés
- Instituto de Instrumentación para Imagen Molecular (I3M), CSIC—Universitat Politècnica de València, Camino de Vera S/N, 46011 Valencia, Spain; (D.A.); (N.J.); (F.C.)
| | - Ian Rivens
- Institute for Cancer Research (ICR), London SM2 5NG, UK; (I.R.); (P.M.)
| | - Petros Mouratidis
- Institute for Cancer Research (ICR), London SM2 5NG, UK; (I.R.); (P.M.)
| | - Noé Jiménez
- Instituto de Instrumentación para Imagen Molecular (I3M), CSIC—Universitat Politècnica de València, Camino de Vera S/N, 46011 Valencia, Spain; (D.A.); (N.J.); (F.C.)
| | - Francisco Camarena
- Instituto de Instrumentación para Imagen Molecular (I3M), CSIC—Universitat Politècnica de València, Camino de Vera S/N, 46011 Valencia, Spain; (D.A.); (N.J.); (F.C.)
| | - Gail ter Haar
- Institute for Cancer Research (ICR), London SM2 5NG, UK; (I.R.); (P.M.)
| |
Collapse
|
26
|
Kook G, Jo Y, Oh C, Liang X, Kim J, Lee SM, Kim S, Choi JW, Lee HJ. Multifocal skull-compensated transcranial focused ultrasound system for neuromodulation applications based on acoustic holography. MICROSYSTEMS & NANOENGINEERING 2023; 9:45. [PMID: 37056421 PMCID: PMC10085992 DOI: 10.1038/s41378-023-00513-3] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/09/2022] [Revised: 01/20/2023] [Accepted: 02/14/2023] [Indexed: 06/05/2023]
Abstract
Transcranial focused ultrasound stimulation is a promising therapeutic modality for human brain disorders because of its noninvasiveness, long penetration depth, and versatile spatial control capability through beamforming and beam steering. However, the skull presents a major hurdle for successful applications of ultrasound stimulation. Specifically, skull-induced focal aberration limits the capability for accurate and versatile targeting of brain subregions. In addition, there lacks a fully functional preclinical neuromodulation system suitable to conduct behavioral studies. Here, we report a miniature ultrasound system for neuromodulation applications that is capable of highly accurate multiregion targeting based on acoustic holography. Our work includes the design and implementation of an acoustic lens for targeting brain regions with compensation for skull aberration through time-reversal recording and a phase conjugation mirror. Moreover, we utilize MEMS and 3D-printing technology to implement a 0.75-g lightweight neuromodulation system and present in vivo characterization of the packaged system in freely moving mice. This preclinical system is capable of accurately targeting the desired individual or multitude of brain regions, which will enable versatile and explorative behavior studies using ultrasound neuromodulation to facilitate widespread clinical adoption.
Collapse
Affiliation(s)
- Geon Kook
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Yehhyun Jo
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Chaerin Oh
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Xiaojia Liang
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Jaewon Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Sang-Mok Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Subeen Kim
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Jung-Woo Choi
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
| | - Hyunjoo Jenny Lee
- School of Electrical Engineering, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 South Korea
- KAIST Institute for NanoCentury (KINC), 291 Daehak-ro, Yuseong-gu, Daejeon, 34141 Republic of Korea
| |
Collapse
|
27
|
Jing B, Strassle Rojas S, Lindsey BD. Effect of skull porosity on ultrasound transmission and wave mode conversion at large incidence angles. Med Phys 2023; 50:3092-3102. [PMID: 36810723 DOI: 10.1002/mp.16318] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Revised: 01/19/2023] [Accepted: 02/06/2023] [Indexed: 02/24/2023] Open
Abstract
BACKGROUND Transcranial ultrasound imaging and therapy depend on the efficient transmission of acoustic energy through the skull. Multiple previous studies have concluded that a large incidence angle should be avoided during transcranial-focused ultrasound therapy to ensure transmission through the skull. Alternatively, some other studies have shown that longitudinal-to-shear wave mode conversion might improve transmission through the skull when the incidence angle is increased above the critical angle (i.e., 25° to 30°). PURPOSE The effect of skull porosity on the transmission of ultrasound through the skull at varying incidence angles was investigated for the first time to elucidate why transmission through the skull at large angles of incidence is decreased in some cases but improved in other cases. METHODS Transcranial ultrasound transmission at varying incidence angles (0°-50°) was investigated in phantoms and ex vivo skull samples with varying bone porosity (0% to 28.54% ± 3.36%) using both numerical and experimental methods. First, the elastic acoustic wave transmission through the skull was simulated using micro-computed tomography data of ex vivo skull samples. The trans-skull pressure was compared between skull segments having three levels of porosity, that is, low porosity (2.65% ± 0.03%), medium porosity (13.41% ± 0.12%), and high porosity (26.9%). Next, transmission through two 3D-printed resin skull phantoms (compact vs. porous phantoms) was experimentally measured to test the effect of porous microstructure alone on ultrasound transmission through flat plates. Finally, the effect of skull porosity on ultrasound transmission was investigated experimentally by comparing transmission through two ex vivo human skull segments having similar thicknesses but different porosities (13.78% ± 2.05% vs. 28.54% ± 3.36%). RESULTS Numerical simulations indicated that an increase in transmission pressure occurs at large incidence angles for skull segments having low porosities but not for those with high porosity. In experimental studies, a similar phenomenon was observed. Specifically, for the low porosity skull sample (13.78% ± 2.05%), the normalized pressure was 0.25 when the incidence angle increased to 35°. However, for the high porosity sample (28.54% ± 3.36%), the pressure was no more than 0.1 at large incidence angles. CONCLUSIONS These results indicate that the skull porosity has an evident effect on the transmission of ultrasound at large incidence angles. The wave mode conversion at large, oblique incidence angles could enhance the transmission of ultrasound through parts of the skull having lower porosity in the trabecular layer. However, for transcranial ultrasound therapy in the presence of highly porous trabecular bone, transmission at a normal incidence angle is preferable relative to oblique incidence angles due to the higher transmission efficiency.
Collapse
Affiliation(s)
- Bowen Jing
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA
| | - Stephan Strassle Rojas
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Brooks D Lindsey
- Wallace H Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA.,School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA
| |
Collapse
|
28
|
Kleven RT, Huang S, Ford SM, Sakthivel K, Thomas SR, Zuccarello M, Herr AB, Holland CK. Effect of Recombinant Tissue Plasminogen Activator and 120-kHz Ultrasound on Porcine Intracranial Thrombus Density. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:539-548. [PMID: 36336551 DOI: 10.1016/j.ultrasmedbio.2022.10.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2022] [Revised: 10/04/2022] [Accepted: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Surgical intervention for the treatment of intracerebral hemorrhage (ICH) has been limited by inadequate lysis of the target thrombus. Adjuvant transcranial ultrasound exposure is hypothesized to improve thrombolysis, expedite hematoma evacuation and improve clinical outcomes. A juvenile porcine intracerebral hemorrhage model was established by direct infusion of autologous blood into the porcine white matter. Thrombi were either not treated (sham) or treated with recombinant tissue plasminogen activator alone (rt-PA only) or in combination with pulsed transcranial 120-kHz ultrasound (sonothrombolysis). After treatment, pigs were euthanized, the heads frozen and sectioned and the thrombi extracted. D-Dimer and thrombus density assays were used to assess degree of lysis. Both porcine and human D-dimer assays tested did not have sufficient sensitivity to detect porcine D-dimer. Thrombi treated with rt-PA with or without 120-kHz ultrasound had a significantly lower density compared with sham-treated thrombi. No enhancement of rt-PA-mediated thrombolysis was noted with the addition of 120-kHz ultrasound (sonothrombolysis). The thrombus density assay revealed thrombolytic efficacy caused by rt-PA in an in vivo juvenile porcine model of intracerebral hemorrhage. Transcranial sonothrombolysis did not enhance rt-PA-induced thrombolysis, likely because of the lack of exogenous cavitation nuclei.
Collapse
Affiliation(s)
- Robert T Kleven
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - Shenwen Huang
- Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - Samantha M Ford
- Neuroscience Program, College of Arts and Sciences, University of Cincinnati, Cincinnati, Ohio, USA
| | - Karthikeyan Sakthivel
- Medical Sciences Program, College of Medicine, University of Cincinnati, Cincinnati, Ohio, USA
| | - Seth R Thomas
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA
| | - Mario Zuccarello
- Department of Neurosurgery, University of Cincinnati, Cincinnati, Ohio, USA
| | - Andrew B Herr
- Division of Immunobiology, Cincinnati Children's Hospital Medical Center, Cincinnati, Ohio, USA
| | - Christy K Holland
- Department of Internal Medicine, Division of Cardiovascular Health and Disease, University of Cincinnati, Cincinnati, Ohio, USA; Department of Biomedical Engineering, College of Engineering and Applied Sciences, University of Cincinnati, Cincinnati, Ohio, USA.
| |
Collapse
|
29
|
Richards LA, Stride E, Cleveland RO. Foam gratings as an alternative to customized acoustic lenses. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2023; 153:17. [PMID: 36732254 DOI: 10.1121/10.0016755] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
This article describes a method of manipulating acoustic fields using transmission through foam gratings. The approach is investigated with an analytical model, a numerical model simulating full wave ultrasound propagation through the gratings, and experimental measurements. A grating is demonstrated that mimics a conventional ultrasound lens, modulating the phase of transmitted ultrasound while maximizing the transmitted amplitude. The performance of a foam grating is compared to a lens made of polydimethylsiloxane or three-dimensional printed resin. Using two gratings, independent control of amplitude and phase is demonstrated, with increased insertion loss. The primary advantages of this technique over conventional lenses are very rapid manufacture (<30 min), high repeatability due to the simplicity of manufacture, and the ability to control the amplitude of the transmitted ultrasound. Potential applications include generation of complex ultrasound fields for patient specific treatments in ultrasound therapy.
Collapse
Affiliation(s)
- Luke A Richards
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Eleanor Stride
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, United Kingdom
| | - Robin O Cleveland
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, United Kingdom
| |
Collapse
|
30
|
Attali D, Tiennot T, Schafer M, Fouragnan E, Sallet J, Caskey CF, Chen R, Darmani G, Bubrick EJ, Butler C, Stagg CJ, Klein-Flügge M, Verhagen L, Yoo SS, Pauly KB, Aubry JF. Three-layer model with absorption for conservative estimation of the maximum acoustic transmission coefficient through the human skull for transcranial ultrasound stimulation. Brain Stimul 2023; 16:48-55. [PMID: 36549480 DOI: 10.1016/j.brs.2022.12.005] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2022] [Revised: 12/05/2022] [Accepted: 12/12/2022] [Indexed: 12/23/2022] Open
Abstract
Transcranial ultrasound stimulation (TUS) has been shown to be a safe and effective technique for non-invasive superficial and deep brain stimulation. Safe and efficient translation to humans requires estimating the acoustic attenuation of the human skull. Nevertheless, there are no international guidelines for estimating the impact of the skull bone. A tissue independent, arbitrary derating was developed by the U.S. Food and Drug Administration to take into account tissue absorption (0.3 dB/cm-MHz) for diagnostic ultrasound. However, for the case of transcranial ultrasound imaging, the FDA model does not take into account the insertion loss induced by the skull bone, nor the absorption by brain tissue. Therefore, the estimated absorption is overly conservative which could potentially limit TUS applications if the same guidelines were to be adopted. Here we propose a three-layer model including bone absorption to calculate the maximum pressure transmission through the human skull for frequencies ranging between 100 kHz and 1.5 MHz. The calculated pressure transmission decreases with the frequency and the thickness of the bone, with peaks for each thickness corresponding to a multiple of half the wavelength. The 95th percentile maximum transmission was calculated over the accessible surface of 20 human skulls for 12 typical diameters of the ultrasound beam on the skull surface, and varies between 40% and 78%. To facilitate the safe adjustment of the acoustic pressure for short ultrasound pulses, such as transcranial imaging or transcranial ultrasound stimulation, a table summarizes the maximum pressure transmission for each ultrasound beam diameter and each frequency.
Collapse
Affiliation(s)
- David Attali
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8063, PSL University, Paris, France; Pôle Paris 16 (Secteurs 17-18) et Pôle Neuro Sainte-Anne, Centre Hospitalier Sainte-Anne, GHU Paris Psychiatrie & Neurosciences, Université Paris Cité, Paris, France
| | - Thomas Tiennot
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8063, PSL University, Paris, France
| | - Mark Schafer
- School of Biomedical Engineering, Science and Health Systems, Drexel University, Philadelphia, PA, USA
| | - Elsa Fouragnan
- Brain Research Imaging Center and School of Psychology, University of Plymouth, Plymouth, UK; School of Psychology, Portland Square, Plymouth PL4 8AA, UK
| | - Jérôme Sallet
- Univ Lyon, Université Lyon 1, Inserm, Stem Cell and Brain Research Institute U1208, Bron, France
| | - Charles F Caskey
- Vanderbilt University Institute of Imaging Sciences, VU Medical Center, Nashville, TN, United States
| | - Robert Chen
- Division of Neurology, Department of Medicine, University of Toronto, Canada; Krembil Research Institute, University Health Network, Toronto, Ontario, Canada
| | - Ghazaleh Darmani
- Krembil Research Institute, University Health Network, Toronto, Ontario, Canada
| | - Ellen J Bubrick
- Brigham and Women's Hospital, Harvard Medical School, Department of Neurology, 75 Francis St., Boston, MA, USA
| | - Christopher Butler
- Department of Brain Sciences, Imperial College London, 9th Floor, Sir Michael Uren Hub, 86 Wood Lane, London, W12 0BZ, UK
| | - Charlotte J Stagg
- Wellcome Centre for Integrative Neuroimaging (WIN), Centre for Functional MRI of the Brain (FMRIB), University of Oxford, Nuffield Department of Clinical Neurosciences, Level 6, West Wing, John Radcliffe Hospital, Oxford OX3 9DU, UK
| | - Miriam Klein-Flügge
- Wellcome Centre for Integrative Neuroimaging (WIN), Centre for Functional MRI of the Brain (FMRIB), University of Oxford, Nuffield Department of Clinical Neurosciences, Level 6, West Wing, John Radcliffe Hospital, Oxford OX3 9DU, UK; Wellcome Centre for Integrative Neuroimaging (WIN), Department of Experimental Psychology, University of Oxford, Tinsley Building, Mansfield Road, Oxford OX1 3TA, UK
| | - Lennart Verhagen
- Donders Institute for Brain, Cognition and Behaviour, Radboud University, 6525 GD Nijmegen, the Netherlands
| | - Seung-Schik Yoo
- Brigham and Women's Hospital, Harvard Medical School, Department of Radiology, 75 Francis St., Boston, MA, USA
| | - Kim Butts Pauly
- Stanford University, Department of Radiology, Stanford CA, 94305, USA
| | - Jean-Francois Aubry
- Physics for Medicine Paris, Inserm U1273, ESPCI Paris, CNRS UMR8063, PSL University, Paris, France.
| |
Collapse
|
31
|
Eames M, Larrabee Z, Hananel A, Padilla F, Aubry JF. Low-Cost Thermochromic Quality Assurance Phantom for Therapeutic Ultrasound Devices: A Proof of Concept. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:269-277. [PMID: 36441031 DOI: 10.1016/j.ultrasmedbio.2022.09.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2022] [Revised: 08/29/2022] [Accepted: 09/01/2022] [Indexed: 06/16/2023]
Abstract
High-intensity focused ultrasound (HIFU) transducer acoustic output can vary over time as a result of an inconsistent power supply, damage to the transducer or deterioration over time. Therefore, easy implementation of a daily quality assurance (DQA) method is of great importance for pre-clinical research and clinical applications. We present here a thermochromic material-based phantom validated by thermal simulations and found to provide repeatable visual power output assessments in fewer than 15 s that are accurate to within 10%. Whereas current available methods such as radiation force balance measurements provide an estimate of the total acoustic power, we explain here that the thermochromic phantom is sensitive to the shape of the acoustic field at focus by changing the aperture of a multi-element transducer with a fixed acoustic power. The proposed phantom allows the end user to visually assess the transducer's functionality without resorting to expensive, time-consuming hydrophone measurements or image analysis.
Collapse
Affiliation(s)
- Matt Eames
- Focused Ultrasound Foundation, Charlottesville, Virginia, USA; Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia, USA
| | | | - Arik Hananel
- Focused Ultrasound Foundation, Charlottesville, Virginia, USA; Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia, USA
| | - Frederic Padilla
- Focused Ultrasound Foundation, Charlottesville, Virginia, USA; Department of Radiology, University of Virginia School of Medicine, Charlottesville, Virginia, USA
| | - Jean-Francois Aubry
- Department of Radiology, University of Virginia School of Medicine, Charlottesville, Virginia, USA; Physics for Medicine Paris, CNRS UMR8063, INSERM U1273, ESPCI Paris, PSL Research University, Paris, France.
| |
Collapse
|
32
|
Barzegar-Fallah A, Gandhi K, Rizwan SB, Slatter TL, Reynolds JNJ. Harnessing Ultrasound for Targeting Drug Delivery to the Brain and Breaching the Blood–Brain Tumour Barrier. Pharmaceutics 2022; 14:pharmaceutics14102231. [PMID: 36297666 PMCID: PMC9607160 DOI: 10.3390/pharmaceutics14102231] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 10/11/2022] [Accepted: 10/17/2022] [Indexed: 11/16/2022] Open
Abstract
Despite significant advances in developing drugs to treat brain tumours, achieving therapeutic concentrations of the drug at the tumour site remains a major challenge due to the presence of the blood–brain barrier (BBB). Several strategies have evolved to enhance brain delivery of chemotherapeutic agents to treat tumours; however, most approaches have several limitations which hinder their clinical utility. Promising studies indicate that ultrasound can penetrate the skull to target specific brain regions and transiently open the BBB, safely and reversibly, with a high degree of spatial and temporal specificity. In this review, we initially describe the basics of therapeutic ultrasound, then detail ultrasound-based drug delivery strategies to the brain and the mechanisms by which ultrasound can improve brain tumour therapy. We review pre-clinical and clinical findings from ultrasound-mediated BBB opening and drug delivery studies and outline current therapeutic ultrasound devices and technologies designed for this purpose.
Collapse
Affiliation(s)
- Anita Barzegar-Fallah
- Department of Anatomy, School of Biomedical Sciences, University of Otago, Dunedin 9016, New Zealand
- Brain Health Research Centre, University of Otago, Dunedin 9016, New Zealand
| | - Kushan Gandhi
- Department of Anatomy, School of Biomedical Sciences, University of Otago, Dunedin 9016, New Zealand
- Brain Health Research Centre, University of Otago, Dunedin 9016, New Zealand
| | - Shakila B. Rizwan
- Brain Health Research Centre, University of Otago, Dunedin 9016, New Zealand
- School of Pharmacy, University of Otago, Dunedin 9016, New Zealand
| | - Tania L. Slatter
- Department of Pathology, Dunedin School of Medicine, University of Otago, Dunedin 9016, New Zealand
| | - John N. J. Reynolds
- Department of Anatomy, School of Biomedical Sciences, University of Otago, Dunedin 9016, New Zealand
- Brain Health Research Centre, University of Otago, Dunedin 9016, New Zealand
- Correspondence: ; Tel.: +64-3-479-5781; Fax: +64-3-479-7254
| |
Collapse
|
33
|
Hu Z, Yang Y, Xu L, Hao Y, Chen H. Binary acoustic metasurfaces for dynamic focusing of transcranial ultrasound. Front Neurosci 2022; 16:984953. [PMID: 36117633 PMCID: PMC9475195 DOI: 10.3389/fnins.2022.984953] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2022] [Accepted: 08/11/2022] [Indexed: 11/30/2022] Open
Abstract
Transcranial focused ultrasound (tFUS) is a promising technique for non-invasive and spatially targeted neuromodulation and treatment of brain diseases. Acoustic lenses were designed to correct the skull-induced beam aberration, but these designs could only generate static focused ultrasound beams inside the brain. Here, we designed and 3D printed binary acoustic metasurfaces (BAMs) for skull aberration correction and dynamic ultrasound beam focusing. BAMs were designed by binarizing the phase distribution at the surface of the metasurfaces. The phase distribution was calculated based on time reversal to correct the skull-induced phase aberration. The binarization enabled the ultrasound beam to be dynamically steered along wave propagation direction by adjusting the operation frequency of the incident ultrasound wave. The designed BAMs were manufactured by 3D printing with two coding bits, a polylactic acid unit for bit "1" and a water unit for bit "0." BAMs for single- and multi-point focusing through the human skull were designed, 3D printed, and validated numerically and experimentally. The proposed BAMs with subwavelength scale in thickness are simple to design, easy to fabric, and capable of correcting skull aberration and achieving dynamic beam steering.
Collapse
Affiliation(s)
- Zhongtao Hu
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO, United States
| | - Yaoheng Yang
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO, United States
| | - Lu Xu
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO, United States
| | - Yao Hao
- Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, MO, United States
| | - Hong Chen
- Department of Biomedical Engineering, Washington University in St. Louis, Saint Louis, MO, United States
- Department of Radiation Oncology, Washington University School of Medicine, Saint Louis, MO, United States
| |
Collapse
|
34
|
Huang Y, Wen P, Song B, Li Y. Numerical investigation of the energy distribution of Low-intensity transcranial focused ultrasound neuromodulation for hippocampus. ULTRASONICS 2022; 124:106724. [PMID: 35299039 DOI: 10.1016/j.ultras.2022.106724] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 03/02/2022] [Accepted: 03/04/2022] [Indexed: 06/14/2023]
Abstract
OBJECTIVE Ultrasonic neuromodulation as a safe and non-invasive brain stimulation method that delivers a low-intensity, focused ultrasound to nervous system tissue in a targeted area of the brain. The objective of this study is to numerically investigate the ultrasound wave propagation and the energy distribution within the brain tissues using customized single element focused ultrasound transducers (SEFT), targeting the hippocampus. METHODS A high resolution detailed human head model with seven tissue types was constructed from magnetic resonance imaging (MRI). A full-wave finite-difference time-domain simulation platform, Sim4life, was then used to simulate a 3D non-linear ultrasound wave equation to the specific region of interest, the hippocampus. Three customized SEFT were used to test the effect of transducer positions, and another customized transducer was used to compare the sensitivity effect on heterogeneous and homogeneous brain models. Finally, the sensitivity and performance of low intensity focusing ultrasound stimulation were evaluated. RESULTS An optimized application of SEFT was customized to deliver 100 W/m2 intensity of energy deposition at the hippocampus region. About 85.65% of the generated volume beam was delivered to the targeted hippocampus region and the beam overlap parameter was affected by different transducer positions. Deflection angle changes of SEFT at the range of ± 5% did not have a significant effect on energy delivery and position displacement. Only 0.5% of peak pressure change was observed between heterogeneous and homogeneous brain models. The sensitivity analysis also showed that the sound speed is the most influential acoustic parameter. SIGNIFICANCE This study demonstrated that ultrasound neuromodulation targeting the depth brain tissue of the hippocampus could be a potential and promising alternative method to some non-acoustic brain stimulation modalities. In the numerical study of ultrasound brain stimulations, ultrasound parameters and the brain model need to be properly determined to simulate the ultrasonic neuromodulations.
Collapse
Affiliation(s)
- Yi Huang
- School of Engineering, University of Southern Queensland, Toowoomba 4350, Australia.
| | - Peng Wen
- School of Engineering, University of Southern Queensland, Toowoomba 4350, Australia
| | - Bo Song
- School of Engineering, University of Southern Queensland, Toowoomba 4350, Australia
| | - Yan Li
- School of Mathematics, Physics and Computing, University of Southern Queensland, Toowoomba 4350, Australia
| |
Collapse
|
35
|
Li L, Diao Y, Wu H, Jiang W. Complementary Acoustic Metamaterial for Penetrating Aberration Layers. ACS APPLIED MATERIALS & INTERFACES 2022; 14:28604-28614. [PMID: 35726703 DOI: 10.1021/acsami.2c06227] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Impedance-matched acoustic materials were developed to improve ultrasound penetration through the aberration layer. The traditional ultrasound layer matching material is called a couplant, which can only enhance ultrasound transmission to soft biological media such as the cartilage and muscle but cannot penetrate hard media such as the bone. Here, we propose a phase-modulated complementary acoustic metamaterial based on the principle of impedance matching, which enables ultrasound to penetrate the bone, and use the equivalent parameter technology of acoustic metamaterials for parameter design. Ultrasonic layer adjustment is performed through 3D printing and corrects bone aberrations. Several configurations were investigated through numerical simulations and experiments in non-reflecting tanks. Specifically, the bone matching layer can be optimally designed for a specific bone thickness and a specific operating frequency of the ultrasound probe, thereby amplifying the ultrasound to penetrate the matching layer and bone. The experimental and simulation results show that the proposed acoustic metamaterial can improve the transmission efficiency of ultrasound through the aberration layer.
Collapse
Affiliation(s)
- Lianchun Li
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Yifan Diao
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Haijun Wu
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| | - Weikang Jiang
- State Key Laboratory of Mechanical System and Vibration, Shanghai Jiao Tong University, Shanghai 200240, P. R. China
| |
Collapse
|
36
|
Andrés D, Jiménez N, Benlloch JM, Camarena F. Numerical Study of Acoustic Holograms for Deep-Brain Targeting through the Temporal Bone Window. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:872-886. [PMID: 35221196 DOI: 10.1016/j.ultrasmedbio.2022.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/24/2021] [Revised: 01/14/2022] [Accepted: 01/16/2022] [Indexed: 06/14/2023]
Abstract
Acoustic holograms can encode complex wavefronts to compensate the aberrations of a therapeutical ultrasound beam propagating through heterogeneous tissues such as the skull, and simultaneously, they can generate diffraction-limited acoustic images, that is, arbitrary shaped focal spots. In this work, we numerically study the performance of acoustic holograms focusing at the thalamic nuclei when the source is located at the temporal bone window. The temporal window is the thinnest area of the lateral skull and it is mainly hairless, so it is a desirable area through which to transmit ultrasonic waves to the deep brain. However, in targeting from this area the bilateral thalamic nuclei are not aligned with the elongated focal spots of conventional focused transducers, and in addition, skull aberrations can distort the focal spot. We found that by using patient-specific holographic lenses coupled to a single-element 650-kHz-frequency 65-mm-aperture source, the focal spot can be sharply adapted to the thalamic nuclei in a bilateral way while skull aberrations are mitigated. Furthermore, the performance of these holograms was studied under misalignment errors between the source and the skull, concluding that for misalignments up to 5°, acoustic images are correctly restored. This work paves the way to designing clinical applications of transcranial ultrasound such as blood-brain barrier opening for drug delivery or deep-brain neuromodulation using this low-cost and personalized technology, presenting desirable aspects for long-term treatments because the patient's head does not need to be shaved completely and skull heating is low.
Collapse
Affiliation(s)
- Diana Andrés
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain
| | - Noé Jiménez
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain.
| | - José M Benlloch
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain
| | - Francisco Camarena
- Instituto de Instrumentación para Imagen Molecular (i3M), Universitat Politècnica de València, Consejo Superior de Investigaciones Científicas (CSIC), València, Spain
| |
Collapse
|
37
|
Iazourene T, Malloul H, Noureddine RM, Oujagir E, Escoffre JM, Bouakaz A. Ultrasound Neurostimulation in Mice: Impact of Ultrasound Settings and Beam Properties. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1053-1063. [PMID: 35041601 DOI: 10.1109/tuffc.2022.3144335] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Ultrasound neurostimulation (USNS) is being investigated as a treatment approach for neuropsychiatric and neurodegenerative disorders. Indeed, unlike the existing methods that use electric or magnetic stimulation, it offers the possibility to modulate brain activity in a noninvasive way, with good spatial specificity and a high penetration capacity. However, there is no consensus yet on ultrasound parameters and beam properties required for efficient neurostimulation. In this context, this preclinical study aimed to elucidate the effect of frequency, peak negative pressure (PNP), pulse duration (PD), and focal spot diameter, on the USNS efficiency. This was done by targeting the motor cortex (M1) of 70 healthy mice and analyzing the elicited motor responses (visually and with electromyography). Also, a further investigation was performed by assessing the corresponding neuronal activity, using c-Fos immunostaining. The results showed that the success rate, a metric that depicts USNS efficacy, increased with PNP in a sigmoidal way, reaching up to 100%. This was verified at different frequencies (0.5, 1, 1.5, and 2.25 MHz) and PDs (53.3, 160, and 320 ms, at 1.5 MHz fixed frequency). Moreover, it was shown that higher PNP values were required to achieve a constant USNS efficacy not only when frequency increased, but also when the focal spot diameter decreased, emphasizing a close link between these acoustic parameters and USNS efficacy. These findings were confirmed with immunohistochemistry (IHC), which showed a strong relationship between neural activation, the applied PNP, and the focal spot diameter.
Collapse
|
38
|
Xu R, O'Reilly MA. Establishing density-dependent longitudinal sound speed in the vertebral lamina. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2022; 151:1516. [PMID: 35364923 DOI: 10.1121/10.0009316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Accepted: 12/26/2021] [Indexed: 06/14/2023]
Abstract
Focused ultrasound treatments of the spinal cord may be facilitated using a phased array transducer and beamforming to correct spine-induced focal aberrations. Simulations can non-invasively calculate aberration corrections using x-ray computed tomography (CT) data that are correlated to density (ρ) and longitudinal sound speed (cL). We aimed to optimize vertebral lamina-specific cL(ρ) functions at a physiological temperature (37 °C) to maximize time domain simulation accuracy. Odd-numbered ex vivo human thoracic vertebrae were imaged with a clinical CT-scanner (0.511 × 0.511 × 0.5 mm), then sonicated with a transducer (514 kHz) focused on the canal via the vertebral lamina. Vertebra-induced signal time shifts were extracted from pressure waveforms recorded within the canals. Measurements were repeated 5× per vertebra, with 2.5 mm vertical vertebra shifts between measurements. Linear functions relating cL with CT-derived density were optimized. The optimized function was cL(ρ)=0.35(ρ-ρw)+ cL,w m/s, where w denotes water, giving the tested laminae a mean bulk density of 1600 ± 30 kg/m3 and a mean bulk cL of 1670 ± 60 m/s. The optimized lamina cL(ρ) function was accurate to λ/16 when implemented in a multi-layered ray acoustics model. This modelling accuracy will improve trans-spine ultrasound beamforming.
Collapse
Affiliation(s)
- Rui Xu
- Department of Medical Biophysics, University of Toronto, 101 College Street, Suite 15-701, Toronto, Ontario, M5G 1L7, Canada
| | - Meaghan A O'Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, 2075 Bayview Avenue, Toronto, Ontario, M4N 3M5, Canada
| |
Collapse
|
39
|
Bancel T, Tiennot T, Aubry JF. Adaptive Ultrasound Focusing Through the Cranial Bone for Non-invasive Treatment of Brain Disorders. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:397-409. [DOI: 10.1007/978-3-030-91979-5_18] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
40
|
Schoen S, Kilinc MS, Lee H, Guo Y, Degertekin FL, Woodworth GF, Arvanitis C. Towards controlled drug delivery in brain tumors with microbubble-enhanced focused ultrasound. Adv Drug Deliv Rev 2022; 180:114043. [PMID: 34801617 PMCID: PMC8724442 DOI: 10.1016/j.addr.2021.114043] [Citation(s) in RCA: 50] [Impact Index Per Article: 16.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2021] [Revised: 09/27/2021] [Accepted: 11/04/2021] [Indexed: 02/06/2023]
Abstract
Brain tumors are particularly challenging malignancies, due to their location in a structurally and functionally distinct part of the human body - the central nervous system (CNS). The CNS is separated and protected by a unique system of brain and blood vessel cells which together prevent most bloodborne therapeutics from entering the brain tumor microenvironment (TME). Recently, great strides have been made through microbubble (MB) ultrasound contrast agents in conjunction with ultrasound energy to locally increase the permeability of brain vessels and modulate the brain TME. As we elaborate in this review, this physical method can effectively deliver a wide range of anticancer agents, including chemotherapeutics, antibodies, and nanoparticle drug conjugates across a range of preclinical brain tumors, including high grade glioma (glioblastoma), diffuse intrinsic pontine gliomas, and brain metastasis. Moreover, recent evidence suggests that this technology can promote the effective delivery of novel immunotherapeutic agents, including immune check-point inhibitors and chimeric antigen receptor T cells, among others. With early clinical studies demonstrating safety, and several Phase I/II trials testing the preclinical findings underway, this technology is making firm steps towards shaping the future treatments of primary and metastatic brain cancer. By elaborating on its key components, including ultrasound systems and MB technology, along with methods for closed-loop spatial and temporal control of MB activity, we highlight how this technology can be tuned to enable new, personalized treatment strategies for primary brain malignancies and brain metastases.
Collapse
Affiliation(s)
- Scott Schoen
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - M. Sait Kilinc
- School of Electrical and Computer Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Hohyun Lee
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Yutong Guo
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - F. Levent Degertekin
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Graeme F. Woodworth
- Department of Neurosurgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA,Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, College Park, MD 20742, USA,Fischell Department of Bioengineering A. James Clarke School of Engineering, University of Maryland
| | - Costas Arvanitis
- Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA,Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30332, USA
| |
Collapse
|
41
|
Badran BW, Caulfield KA, Stomberg-Firestein S, Summers PM, Dowdle LT, Savoca M, Li X, Austelle CW, Short EB, Borckardt JJ, Spivak N, Bystritsky A, George MS. Sonication of the Anterior Thalamus With MRI-Guided Transcranial Focused Ultrasound (tFUS) Alters Pain Thresholds in Healthy Adults: A Double-Blind, Sham-Controlled Study. FOCUS (AMERICAN PSYCHIATRIC PUBLISHING) 2022; 20:90-99. [PMID: 35746940 PMCID: PMC9063607 DOI: 10.1176/appi.focus.20109] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2020] [Revised: 10/12/2020] [Accepted: 10/12/2020] [Indexed: 01/03/2023]
Abstract
(Appeared originally in Brain Stimulation 2020; 13:1805-1812) Reprinted with permission from Elsevier.
Collapse
|
42
|
Adams C, Jones RM, Yang SD, Kan WM, Leung K, Zhou Y, Lee KU, Huang Y, Hynynen K. Implementation of a Skull-Conformal Phased Array for Transcranial Focused Ultrasound Therapy. IEEE Trans Biomed Eng 2021; 68:3457-3468. [PMID: 33950835 PMCID: PMC11979958 DOI: 10.1109/tbme.2021.3077802] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
OBJECTIVE To implement a skull-conformal phased array for ultrasound-guided transcranial focused ultrasound therapy with improved patient comfort. METHODS Using patient-specific computed tomography and MRI neuroimaging data, tightly-conforming helmet scaffolds were designed computationally. The helmet scaffolds were designed to hold reusable transducer modules at near-normal incidence in an optimal configuration for the treatment location(s) of interest. Numerical simulations of trans-skull ultrasound propagation were performed to evaluate different conformal array designs and to compare with hemispherical arrays similar to those employed clinically. A 4096-element phased array was constructed by 3D printing a helmet scaffold optimised for an ex vivo human skullcap, and its performance was evaluated via benchtop and in vivo experiments. RESULTS Acoustic field measurements confirmed the system's ability to focus through human skull bone using simulation-based transcranial aberration corrections. Preliminary in vivo testing demonstrated safe trans-human skull blood-brain barrier (BBB) opening in rodents. CONCLUSION Patient-specific conformal ultrasound phased arrays appear to be a feasible and safe approach for conducting transcranial BBB opening procedures. SIGNIFICANCE Skull-conformal phased arrays stand to improve patient comfort and have the potential to accelerate the adoption of transcranial FUS therapy by improving access to the technology.
Collapse
|
43
|
Bakaric M, Miloro P, Javaherian A, Cox BT, Treeby BE, Brown MD. Measurement of the ultrasound attenuation and dispersion in 3D-printed photopolymer materials from 1 to 3.5 MHz. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 150:2798. [PMID: 34717448 DOI: 10.1121/10.0006668] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Accepted: 09/21/2021] [Indexed: 06/13/2023]
Abstract
Over the past decade, the range of applications in biomedical ultrasound exploiting 3D printing has rapidly expanded. For wavefront shaping specifically, 3D printing has enabled a diverse range of new, low-cost approaches for controlling acoustic fields. These methods rely on accurate knowledge of the bulk acoustic properties of the materials; however, to date, robust knowledge of these parameters is lacking for many materials that are commonly used. In this work, the acoustic properties of eight 3D-printed photopolymer materials were characterised over a frequency range from 1 to 3.5 MHz. The properties measured were the frequency-dependent phase velocity and attenuation, group velocity, signal velocity, and mass density. The materials were fabricated using two separate techniques [PolyJet and stereolithograph (SLA)], and included Agilus30, FLXA9960, FLXA9995, Formlabs Clear, RGDA8625, RGDA8630, VeroClear, and VeroWhite. The range of measured density values across all eight materials was 1120-1180 kg · m-3, while the sound speed values were between 2020 to 2630 m · s-1, and attenuation values typically in the range 3-9 dB · MHz-1· cm-1.
Collapse
Affiliation(s)
- Marina Bakaric
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Piero Miloro
- Ultrasound and Underwater Acoustics, National Physical Laboratory, Hampton Road, Teddington TW11 0LW, United Kingdom
| | - Ashkan Javaherian
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Ben T Cox
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Bradley E Treeby
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| | - Michael D Brown
- Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, United Kingdom
| |
Collapse
|
44
|
Jimenez-Gambin S, Jimenez N, Pouliopoulos A, Benlloch JM, Konofagou E, Camarena F. Acoustic holograms for bilateral blood-brain barrier opening in a mouse model. IEEE Trans Biomed Eng 2021; 69:1359-1368. [PMID: 34570701 DOI: 10.1109/tbme.2021.3115553] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Transcranial focused ultrasound (FUS) in conjunction with circulating microbubbles injection is the sole non-invasive technique that temporally and locally opens the blood-brain barrier (BBB), allowing targeted drug delivery into the central nervous system (CNS). However, single-element FUS technologies do not allow the simultaneous targeting of several brain structures with high-resolution, and multi-element devices are required to compensate the aberrations introduced by the skull. In this work, we present the first preclinical application of acoustic holograms to perform a bilateral BBB opening in two mirrored regions in mice. The system consisted of a single-element focused transducer working at 1.68~MHz, coupled to a 3D-printed acoustic hologram designed to produce two symmetric foci in anesthetized mice \textit{in vivo} and, simultaneously, compensate the aberrations of the wavefront caused by the skull bones. T1-weighed MR images showed gadolinium extravasation at two symmetric quasi-spherical focal spots. By encoding time-reversed fields, holograms are capable of focusing acoustic energy with a resolution near the diffraction limit at multiple spots inside the skull of small preclinical animals. This work demonstrates the feasibility of hologram-assisted BBB opening for low-cost and highly-localized targeted drug delivery in the CNS in symmetric regions of separate hemispheres.
Collapse
|
45
|
McMahon D, O'Reilly MA, Hynynen K. Therapeutic Agent Delivery Across the Blood-Brain Barrier Using Focused Ultrasound. Annu Rev Biomed Eng 2021; 23:89-113. [PMID: 33752471 PMCID: PMC11979953 DOI: 10.1146/annurev-bioeng-062117-121238] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Specialized features of vasculature in the central nervous system greatly limit therapeutic treatment options for many neuropathologies. Focused ultrasound, in combination with circulating microbubbles, can be used to transiently and noninvasively increase cerebrovascular permeability with a high level of spatial precision. For minutes to hours following sonication, drugs can be administered systemically to extravasate in the targeted brain regions and exert a therapeutic effect, after which permeability returns to baseline levels. With the wide range of therapeutic agents that can be delivered using this approach and the growing clinical need, focused ultrasound and microbubble (FUS+MB) exposure in the brain has entered human testing to assess safety. This review outlines the use of FUS+MB-mediated cerebrovascular permeability enhancement as a drug delivery technique, details several technical and biological considerations of this approach, summarizes results from the clinical trials conducted to date, and discusses the future direction of the field.
Collapse
Affiliation(s)
- Dallan McMahon
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada;
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5, Canada
| | - Meaghan A O'Reilly
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada;
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5, Canada
| | - Kullervo Hynynen
- Physical Sciences Platform, Sunnybrook Research Institute, Toronto, Ontario M4N 3M5, Canada;
- Department of Medical Biophysics, University of Toronto, Toronto, Ontario M4N 3M5, Canada
- Institute of Biomaterials and Biomedical Engineering, University of Toronto, Toronto, Ontario M4N 3M5, Canada
| |
Collapse
|
46
|
Bancel T, Houdouin A, Annic P, Rachmilevitch I, Shapira Y, Tanter M, Aubry JF. Comparison Between Ray-Tracing and Full-Wave Simulation for Transcranial Ultrasound Focusing on a Clinical System Using the Transfer Matrix Formalism. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:2554-2565. [PMID: 33651688 DOI: 10.1109/tuffc.2021.3063055] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Only one high-intensity focused ultrasound device has been clinically approved for transcranial brain surgery at the time of writing. The device operates within 650 and 720 kHz and corrects the phase distortions induced by the skull of each patient using a multielement phased array. Phase correction is estimated adaptively using a proprietary algorithm based on computed-tomography (CT) images of the patient's skull. In this article, we assess the performance of the phase correction computed by the clinical device and compare it to: 1) the correction obtained with a previously validated full-wave simulation algorithm using an open-source pseudo-spectral toolbox and 2) a hydrophone-based correction performed invasively to measure the aberrations induced by the skull at 650 kHz. For the full-wave simulation, three different mappings between CT Hounsfield units and the longitudinal speed of sound inside the skull were tested. All methods are compared with the exact same setup due to transfer matrices acquired with the clinical system for N = 5 skulls and T = 2 different targets for each skull. We show that the clinical ray-tracing software and the full-wave simulation restore, respectively, 84% ± 5% and 86% ± 5% of the pressure obtained with hydrophone-based correction for targets located in central brain regions. On the second target (off-center), we also report that the performance of both algorithms degrades when the average incident angles of the acoustic beam at the skull surface increase. When incident angles are higher than 20°, the restored pressure drops below 75% of the pressure restored with hydrophone-based correction.
Collapse
|
47
|
Li Z, Guo R, Chen D, Fei C, Yang X, Li D, Zheng C, Chen J, Wu R, Feng W, Xu Z, Yang Y. An Efficient Optimization Design of Liquid Lens for Acoustic Pattern Control. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:1546-1554. [PMID: 33232228 DOI: 10.1109/tuffc.2020.3040174] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In order to effectively and flexibly control acoustic pattern, an efficient optimization design method of acoustic liquid lens (ALL) is developed by the frame of particle swarm optimization (PSO) algorithm. The ALL is composed of ethanol and dimethicone, and its parameters include ethanol concentration (EC), volume fraction of dimethicone (VFD), and total volume (TV). Based on the established finite element model and orthogonal design method, the data of acoustic pattern and ALL can be obtained by using COMSOL Multiphysics. Based on the simulation data, the neural network models are constructed to characterize the relationship between the parameters of ALL and the performance of acoustic pattern. The optimization design criteria of ALL are constructed based on the performance parameters of acoustic pattern, including focal distance (FD), transverse resolution (TR), and longitudinal resolution (LR). Based on the optimization criteria, the modified PSO algorithm is utilized to optimize the design parameters of ALL in the developed method. According to the desired FD, TR, and LR of acoustic pattern (20, 1, and 17 mm), the optimized EC, VFD, and TV of ALL are about 0.838, 0.165, and 164.4 [Formula: see text]. The performance parameters of acoustic pattern verified by simulation and experiments agree with the desired ones. In addition, using 6 MHz ultrasonic transducer with the optimized ALL, the ultrasonic imaging of tungsten wires and porcine eyeball further demonstrates the effectiveness and feasibility of the developed method.
Collapse
|
48
|
Lee W, Weisholtz DS, Strangman GE, Yoo SS. Safety Review and Perspectives of Transcranial Focused Ultrasound Brain Stimulation. BRAIN & NEUROREHABILITATION 2021; 14:e4. [PMID: 36742103 PMCID: PMC9879416 DOI: 10.12786/bn.2021.14.e4] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Revised: 02/17/2021] [Accepted: 03/04/2021] [Indexed: 11/08/2022] Open
Abstract
Ultrasound is an important theragnostic modality in modern medicine. Technical advancement of both acoustic focusing and transcranial delivery have enabled administration of ultrasound waves to localized brain areas with few millimeters of spatial specificity and penetration depth sufficient to reach the thalamus. Transcranial focused ultrasound (tFUS) given at a low acoustic intensity has been shown to increase or suppress the excitability of region-specific brain areas. The neuromodulatory effects can outlast the sonication, suggesting the possibility of inducing neural plasticity needed for neurorehabilitation. Increasing numbers of studies have shown the efficacy and excellent safety profile of the technique, yet comparisons among the safety-related parameters have not been compiled. This review aims to provide safety information and perspectives of tFUS brain stimulation. First, the acoustic parameters most relevant to thermal/mechanical tissue damage are discussed along with regulated parameters for existing ultrasound therapies/diagnostic imaging. Subsequently, the parameters used in studies of large animals, non-human primates, and humans are surveyed and summarized in terms of the acoustic intensity and the mechanical index. The pulse-mode operation and the use of low ultrasound frequency for tFUS-mediated brain stimulation warrant the establishment of new safety guidelines/recommendations for the use of the technique among healthy volunteers, with additional cautionary requirements for its clinical translation.
Collapse
Affiliation(s)
- Wonhye Lee
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Daniel S. Weisholtz
- Department of Neurology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| | - Gary E. Strangman
- Neural Systems Group, Massachusetts General Hospital, Harvard Medical School, Charlestown, MA, USA
- Center for Space Medicine, Baylor College of Medicine, Houston, TX, USA
- Translational Research Institute, Houston, TX, USA
| | - Seung-Schik Yoo
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
49
|
Lowe KA, Zinke W, Phipps MA, Cosman J, Maddox M, Schall JD, Caskey CF. Visuomotor Transformations Are Modulated by Focused Ultrasound over Frontal Eye Field. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:679-692. [PMID: 33341303 DOI: 10.1016/j.ultrasmedbio.2020.11.022] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2020] [Revised: 11/16/2020] [Accepted: 11/19/2020] [Indexed: 06/12/2023]
Abstract
Neuromodulation with focused ultrasound (FUS) is being widely explored as a non-invasive tool to stimulate focal brain regions because of its superior spatial resolution and coverage compared with other neuromodulation methods. The precise effects of FUS stimulation on specific regions of the brain are not yet fully understood. Here, we characterized the behavioral effects of FUS stimulation directly applied through a craniotomy over the macaque frontal eye field (FEF). In macaque monkeys making directed eye movements to perform visual search tasks with direct or arbitrary responses, focused ultrasound was applied through a craniotomy over the FEF. Saccade response times (RTs) and error rates were determined for trials without or with FUS stimulation with pulses at a peak negative pressure of either 250 or 425 kPa. Both RTs and error rates were affected by FUS. Responses toward a target located contralateral to the FUS stimulation were approximately 3 ms slower in the presence of FUS in both monkeys studied, while only one exhibited a slowing of responses for ipsilateral targets. Error rates were lower in one monkey in this study. In another search task requiring making eye movements toward a target (pro-saccades) or in the opposite direction (anti-saccades), the RT for pro-saccades increased in the presence of FUS stimulation. Our results indicate the effectiveness of FUS to modulate saccadic responses when stimulating FEF in awake, behaving non-human primates.
Collapse
Affiliation(s)
- Kaleb A Lowe
- Center for Integrative and Cognitive Neuroscience, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA; Vanderbilt Vision Research Center, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA
| | - Wolf Zinke
- Center for Integrative and Cognitive Neuroscience, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA; Vanderbilt Vision Research Center, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA
| | - M Anthony Phipps
- Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee, USA; Institute of Imaging Science, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA
| | - Josh Cosman
- Center for Integrative and Cognitive Neuroscience, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA; Vanderbilt Vision Research Center, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA
| | - Micala Maddox
- Center for Integrative and Cognitive Neuroscience, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA; Vanderbilt Vision Research Center, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA
| | - Jeffrey D Schall
- Center for Integrative and Cognitive Neuroscience, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA; Vanderbilt Vision Research Center, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA
| | - Charles F Caskey
- Vanderbilt Vision Research Center, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA; Institute of Imaging Science, Department of Psychology, Vanderbilt University, Nashville, Tennessee, USA.
| |
Collapse
|
50
|
Qu X, Shen G, Wu N, Wu H, Qiao S, Wang E, Chen Y, Wang H. Suppressing Grating Lobes for Transcranial Focused Ultrasound System by Frequency-Modulated Excitation. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2021; 68:341-351. [PMID: 33382650 DOI: 10.1109/tuffc.2020.3047664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
Transcranial focused ultrasound is a novel noninvasive therapeutic modality for glioblastoma and other disorders of the brain. However, because the phase aberrations caused by the skull need to be corrected with computed tomography (CT) images, the transcranial transducer is tightly fixed on the patient's head to avoid any variation in the relative position, and the focus shifting relies mainly on the capacity for electronic beam steering. Due to the presence of grating lobes and the rapid degradation of the focus quality with increasing focus-shifting distance, transcranial focus-shifting sonication may damage healthy brain tissue unintentionally. To reduce the risks associated with transcranial focused ultrasound therapy, linear frequency-modulated (FM) excitation is proposed. The k-space corrected pseudospectral time domain (PSTD) and acoustic holography approach based on the Rayleigh integral are combined to calculate the distribution of the deposited acoustic power. The corresponding simulation was performed with axial/lateral focus shifting at different distances. The distributions of the deposited acoustic power show that linear FM excitation can effectively suppress undesired prefocal grating lobes without compromising focus quality.
Collapse
|