Klintström E, Klintström B, Smedby Ö, Moreno R. Automated region growing-based segmentation for trabecular bone structure in fresh-frozen human wrist specimens. BMC Med Imaging 2024; 24:101. [PMID: 38693510 PMCID: PMC11061919 DOI: 10.1186/s12880-024-01281-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 04/23/2024] [Indexed: 05/03/2024] Open
Abstract
Bone strength depends on both mineral content and bone structure. Measurements of bone microstructure on specimens can be performed by micro-CT. In vivo measurements are reliably performed by high-resolution peripheral computed tomography (HR-pQCT) using dedicated software. In previous studies from our research group, trabecular bone properties on CT data of defatted specimens from many different CT devices have been analyzed using an Automated Region Growing (ARG) algorithm-based code, showing strong correlations to micro-CT.The aim of the study was to validate the possibility of segmenting and measuring trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens. Data from micro-CT was used as reference. The hypothesis was that the ARG-based in-house built software could be used for such measurements.HR-pQCT image data at two resolutions (61 and 82 µm isotropic voxels) from 23 fresh-frozen human forearms were analyzed. Correlations to micro-CT were strong, varying from 0.72 to 0.99 for all parameters except trabecular termini and nodes. The bone volume fraction had correlations varying from 0.95 to 0.98 but was overestimated compared to micro-CT, especially at the lower resolution. Trabecular separation and spacing were the most stable parameters with correlations at 0.80-0.97 and mean values in the same range as micro-CT.Results from this in vitro study show that an ARG-based software could be used for segmenting and measuring 3D trabecular bone structure from clinical CT data of fresh-frozen human wrist specimens using micro-CT data as reference. Over-and underestimation of several of the bone structure parameters must however be taken into account.
Collapse
Affiliation(s)
- Eva Klintström
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, SE-58185, Sweden.
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, SE-58185, Sweden.
| | - Benjamin Klintström
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden
| | - Örjan Smedby
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden
| | - Rodrigo Moreno
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, Huddinge, SE-14157, Sweden
| |
Collapse
|
2
|
Kasaeian A, Roemer FW, Ghotbi E, Ibad HA, He J, Wan M, Zbijewski WB, Guermazi A, Demehri S. Subchondral bone in knee osteoarthritis: bystander or treatment target? Skeletal Radiol 2023; 52:2069-2083. [PMID: 37646795 DOI: 10.1007/s00256-023-04422-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2022] [Revised: 08/01/2023] [Accepted: 08/01/2023] [Indexed: 09/01/2023]
Abstract
The subchondral bone is an important structural component of the knee joint relevant for osteoarthritis (OA) incidence and progression once disease is established. Experimental studies have demonstrated that subchondral bone changes are not simply the result of altered biomechanics, i.e., pathologic loading. In fact, subchondral bone alterations have an impact on joint homeostasis leading to articular cartilage loss already early in the disease process. This narrative review aims to summarize the available and emerging imaging techniques used to evaluate knee OA-related subchondral bone changes and their potential role in clinical trials of disease-modifying OA drugs (DMOADs). Radiographic fractal signature analysis has been used to quantify OA-associated changes in subchondral texture and integrity. Cross-sectional modalities such as cone-beam computed tomography (CT), contrast-enhanced cone beam CT, and micro-CT can also provide high-resolution imaging of the subchondral trabecular morphometry. Magnetic resonance imaging (MRI) has been the most commonly used advanced imaging modality to evaluate OA-related subchondral bone changes such as bone marrow lesions and altered trabecular bone texture. Dual-energy X-ray absorptiometry can provide insight into OA-related changes in periarticular subchondral bone mineral density. Positron emission tomography, using physiological biomarkers of subchondral bone regeneration, has provided additional insight into OA pathogenesis. Finally, artificial intelligence algorithms have been developed to automate some of the above subchondral bone measurements. This paper will particularly focus on semiquantitative methods for assessing bone marrow lesions and their utility in identifying subjects at risk of symptomatic and structural OA progression, and evaluating treatment responses in DMOAD clinical trials.
Collapse
Affiliation(s)
- Arta Kasaeian
- Musculoskeletal Radiology, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Frank W Roemer
- Department of Radiology, Boston University School of Medicine, Boston, MA, USA
- Department of Radiology, University of Erlangen-Nuremberg, Erlangen, Germany
| | - Elena Ghotbi
- Musculoskeletal Radiology, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Hamza Ahmed Ibad
- Musculoskeletal Radiology, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Jianwei He
- Department of Orthopedic Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Mei Wan
- Department of Orthopedic Surgery, Johns Hopkins University School of Medicine, Baltimore, MD, USA
| | - Wojciech B Zbijewski
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA
| | - Ali Guermazi
- Department of Radiology, Boston University School of Medicine, Boston, MA, USA
| | - Shadpour Demehri
- Musculoskeletal Radiology, Russell H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
| |
Collapse
|
3
|
Fertaki S, Giannoutsou P, Orkoula MG. Combining Raman Microspectroscopy and X-ray Microcomputed Tomography for the Study of Bone Quality in Apolipoprotein-Deficient Animal Models. Molecules 2023; 28:7196. [PMID: 37894675 PMCID: PMC10609250 DOI: 10.3390/molecules28207196] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2023] [Revised: 10/04/2023] [Accepted: 10/16/2023] [Indexed: 10/29/2023] Open
Abstract
Raman microspectroscopy and X-ray microcomputed tomography (micro-CT) were used for assessment of the quality of the femur and tibia bones in apolipoprotein-deficient mice compared to control littermates. The cortical and trabecular bone was investigated separately. Raman spectra revealed no differences in the bioapatite-to-collagenous matrix ratio of the cortical bone. The quantities of calcium and collagen, which were measured using atomic absorption spectrometry and thermogravimetric analysis, respectively, were also found to be equal in the two groups. Density and morphometric parameters, which were measured using micro-CT, verified the cortical mineral stability. Bone quality indices were measured using Raman spectra. A decreased collagen crosslink (trivalent-to-divalent) ratio revealed delayed maturation of the collagen network. Such a decrease has been reported in the literature to be connected to decreased bone strength. For the trabecular bone, micro-CT revealed severe osteoporosis in the knock-out group, which was evident from a decreased mineral density, trabecular thickness and increased bone surface/volume ratio. The trabecular bone was not accessible for Raman spectroscopy. According to these results, the cortical and trabecular femur bone is expected to exhibit proneness to fracturing, each for a different reason. A combination of the two techniques was regarded as necessary for an overall assessment of bone quality.
Collapse
Affiliation(s)
- Stefani Fertaki
- Department of Pharmacy, University of Patras, 265 04 Patras, Greece
- Foundation for Research and Technology, Institute of Chemical Engineering and High Temperatures, FORTH/ICE-HT, 265 04 Patras, Greece
| | - Panagiota Giannoutsou
- Department of Pharmacy, University of Patras, 265 04 Patras, Greece
- Foundation for Research and Technology, Institute of Chemical Engineering and High Temperatures, FORTH/ICE-HT, 265 04 Patras, Greece
| | | |
Collapse
|
4
|
Poiana IR, Dobre R, Popescu RI, Pituru SM, Bucur A. Utility of Cone-Beam Computed Tomography in the Detection of Low Bone Mass-A Systematic Review. J Clin Med 2023; 12:5890. [PMID: 37762831 PMCID: PMC10531931 DOI: 10.3390/jcm12185890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2023] [Revised: 09/05/2023] [Accepted: 09/06/2023] [Indexed: 09/29/2023] Open
Abstract
INTRODUCTION Cone-beam computed tomography (CBCT) is widely used in the preoperative qualitative and quantitative assessment of dental implant sites, offering dimensional accuracy, spatial resolution, gray density, and contrast comparable to those of classical CT scan, yet with disputable ability to determine bone mass density. MATERIALS AND METHODS A systematic review of the literature was performed using the PubMed and SCOPUS databases, with terms referring to low bone mass and cone-beam computed tomography (CBCT). RESULTS Sixteen studies were included in the review. The results show different perspectives, but the evidence favors the use of CBCT, combined with dual-energy X-ray absorptiometry bone density scan (DXA) evaluation, for the assessment of the osteoporosis status of the aging population and, more specifically, in postmenopausal women. Radiographic density (RD) values of the dens and the left part of the first cervical vertebra show the strongest correlation coefficients and the highest sensitivity, specificity, and accuracy for predicting osteoporosis (OP) in the lumbar vertebrae and the femoral neck. CONCLUSIONS Our review suggests the potential of CBCT as a screening tool for patients with low bone mass using different radiomorphometric indices. Linear measurements of the inferior mandibular cortex were lower in osteoporotic individuals, indicating the perspective of CBCT also as a diagnostic tool for this disease.
Collapse
Affiliation(s)
- Ioana Ruxandra Poiana
- Faculty of Medicine, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (I.R.P.); (R.-I.P.); (S.-M.P.); (A.B.)
| | - Ramona Dobre
- Faculty of Medicine, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (I.R.P.); (R.-I.P.); (S.-M.P.); (A.B.)
- Department of Endocrinology, National Institute of Endocrinology C. I. Parhon, 011853 Bucharest, Romania
| | - Razvan-Ionut Popescu
- Faculty of Medicine, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (I.R.P.); (R.-I.P.); (S.-M.P.); (A.B.)
- Department of Endocrinology, National Institute of Endocrinology C. I. Parhon, 011853 Bucharest, Romania
- Department of Urology, “Prof. Dr. Th. Burghele” Clinical Hospital, 050659 Bucharest, Romania
| | - Silviu-Mirel Pituru
- Faculty of Medicine, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (I.R.P.); (R.-I.P.); (S.-M.P.); (A.B.)
| | - Alexandru Bucur
- Faculty of Medicine, “Carol Davila” University of Medicine and Pharmacy, 050474 Bucharest, Romania; (I.R.P.); (R.-I.P.); (S.-M.P.); (A.B.)
| |
Collapse
|
5
|
Hasegawa H, Nango N, Machida M. Evaluation of Trabecular Microstructure of Cancellous Bone Using Quarter-Detector Computed Tomography. Diagnostics (Basel) 2023; 13:diagnostics13071240. [PMID: 37046458 PMCID: PMC10093188 DOI: 10.3390/diagnostics13071240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2023] [Revised: 03/22/2023] [Accepted: 03/23/2023] [Indexed: 03/29/2023] Open
Abstract
Quarter-detector computed tomography (QDCT) is an ultra-high-spatial-resolution imaging technique. This study aimed to verify the validity of trabecular structure evaluation using a QDCT scanner in the diagnosis of osteoporosis. We used a cancellous bone specimen image of the second lumbar vertebrae of an adult male with moderate osteoporosis. To obtain QDCT images, we created a three-dimensional model from micro-CT images of the specimen. Statistical analysis was performed on the relationship between micro-CT and QDCT imaging modalities. The differences between micro-CT and QDCT were assessed based on their significance with respect to the calculated mean measurements using the Mann–Whitney test. Single regression analysis was performed using linear regression, with micro-CT and QDCT as the explanatory and objective variables, respectively, to determine the relationship of the measured values between the two modalities. By applying the necessary correction to the micro-CT measured values, it is possible to perform an analysis equivalent to micro-CT, which offers higher spatial resolution than QDCT. We found evidence that if QDCT can be used, trabecular structure evaluation may contribute to image diagnosis to evaluate practical bone fragility.
Collapse
|
6
|
Huflage H, Grunz JP, Kunz AS, Patzer TS, Sauer ST, Christner SA, Petritsch B, Ergün S, Bley TA, Luetkens KS. Potential of employing a quantum iterative reconstruction algorithm for ultra-high-resolution photon-counting detector CT of the hip. Radiography (Lond) 2023; 29:44-49. [PMID: 36274316 DOI: 10.1016/j.radi.2022.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2022] [Revised: 09/14/2022] [Accepted: 09/26/2022] [Indexed: 11/06/2022]
Abstract
INTRODUCTION This study investigated the image quality of a new quantum iterative reconstruction algorithm (QIR) for high resolution photon-counting CT of the hip. METHODS Using a first-generation photon-counting CT scanner, five cadaveric specimens were examined with ultra-high-resolution protocols matched for radiation dose. Images were post-processed with a sharp convolution kernel and five different strength levels of iterative reconstruction (QIR 0 - QIR 4). Subjective image quality was rated independently by three radiologists on a five-point scale. Intraclass correlation coefficients (ICC) were computed for assessing interrater agreement. Objective image quality was evaluated by means of contrast-to-noise-ratios (CNR) in bone and muscle tissue. RESULTS For osseous tissue, subjective image quality was rated best for QIR 2 reformatting (median 5 [interquartile range 5-5]). Contrarily, for soft tissue, QIR 4 received the highest ratings among compared strength levels (3 [3-4]). Both ICCbone (0.805; 95% confidence interval 0.711-0.877; p < 0.001) and ICCmuscle (0.885; 0.824-0.929; p < 0.001) suggested good interrater agreement. CNR in bone and muscle tissue increased with ascending strength levels of iterative reconstruction with the highest results recorded for QIR 4 (CNRbone 29.43 ± 2.61; CNRmuscle 8.09 ± 0.77) and lowest results without QIR (CNRbone 3.90 ± 0.29; CNRmuscle 1.07 ± 0.07) (all p < 0.001). CONCLUSION Reconstructing photon-counting CT data with an intermediate QIR strength level appears optimal for assessment of osseous tissue, whereas soft tissue analysis benefitted from applying the highest strength level available. IMPLICATIONS FOR PRACTICE Quantum iterative reconstruction technique can enhance image quality by significantly reducing noise and improving CNR in ultra-high resolution CT imaging of the hip.
Collapse
Affiliation(s)
- H Huflage
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - J-P Grunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - A S Kunz
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - T S Patzer
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - S T Sauer
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - S A Christner
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - B Petritsch
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - S Ergün
- Institute of Anatomy and Cell Biology, University of Würzburg, Koellikerstraße 6, 97070 Würzburg, Germany.
| | - T A Bley
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| | - K S Luetkens
- Department of Diagnostic and Interventional Radiology, University Hospital Würzburg, Oberdürrbacher Straße 6, 97080 Würzburg, Germany.
| |
Collapse
|
7
|
Klintström E, Klintström B, Spångeus A, Sandborg M, Woisetschläger M. Trabecular bone microstructure analysis on data from a novel twin robotic X-ray device. Acta Radiol 2022; 64:1566-1572. [PMID: 36373570 PMCID: PMC10088033 DOI: 10.1177/02841851221134973] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background Bone strength is related to both mineral density (BMD) and the bone microstructure. However, only the assessment of BMD is available in clinical routine care today. Purpose To analyze and study the correlation of trabecular bone microstructure from the imaging data of a prototype Multitom Rax system, using micro-computed tomography (CT) data as the reference method (Skyscan 1176). Material and Methods Imaging data from 14 bone samples from the human radius were analyzed regarding six bone structure parameters, i.e. trabecular nodes, separation, spacing, and thickness as well as bone volume (BV/TV) and structural model index (SMI). Results All six structure parameters showed strong correlations to micro-CT with Spearman correlation coefficients in the range of 0.83–0.93. BV/TV and SMI had a correlation >0.90. Two of the parameters, namely, separation and number, had mean values in the same range as micro-CT. The other four were either over- or underestimated. Conclusion The strong correlation between micro-CT and the clinical imaging system, indicates the possibility for analyzing bone microstructure with potential to add value in fracture assessment using the studied device in a clinical workflow.
Collapse
Affiliation(s)
- Eva Klintström
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Benjamin Klintström
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Stockholm, Sweden
| | - Anna Spångeus
- Department of Acute Internal Medicine and Geriatrics/Department of Endocrinology, Linköping University Hospital, Linköping, Sweden
- Division of Diagnostics and Specialist Medicine, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Michael Sandborg
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
- Department of Medical Radiation Physics, Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
| | - Mischa Woisetschläger
- Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, Linköping, Sweden
- Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| |
Collapse
|
8
|
Klintström B, Henriksson L, Moreno R, Malusek A, Smedby Ö, Woisetschläger M, Klintström E. Photon-counting detector CT and energy-integrating detector CT for trabecular bone microstructure analysis of cubic specimens from human radius. Eur Radiol Exp 2022; 6:31. [PMID: 35882679 PMCID: PMC9325937 DOI: 10.1186/s41747-022-00286-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2022] [Accepted: 05/23/2022] [Indexed: 12/03/2022] Open
Abstract
Background As bone microstructure is known to impact bone strength, the aim of this in vitro study was to evaluate if the emerging photon-counting detector computed tomography (PCD-CT) technique may be used for measurements of trabecular bone structures like thickness, separation, nodes, spacing and bone volume fraction. Methods Fourteen cubic sections of human radius were scanned with two multislice CT devices, one PCD-CT and one energy-integrating detector CT (EID-CT), using micro-CT as a reference standard. The protocols for PCD-CT and EID-CT were those recommended for inner- and middle-ear structures, although at higher mAs values: PCD-CT at 450 mAs and EID-CT at 600 (dose equivalent to PCD-CT) and 1000 mAs. Average measurements of the five bone parameters as well as dispersion measurements of thickness, separation and spacing were calculated using a three-dimensional automated region growing (ARG) algorithm. Spearman correlations with micro-CT were computed. Results Correlations with micro-CT, for PCD-CT and EID-CT, ranged from 0.64 to 0.98 for all parameters except for dispersion of thickness, which did not show a significant correlation (p = 0.078 to 0.892). PCD-CT had seven of the eight parameters with correlations ρ > 0.7 and three ρ > 0.9. The dose-equivalent EID-CT instead had four parameters with correlations ρ > 0.7 and only one ρ > 0.9. Conclusions In this in vitro study of radius specimens, strong correlations were found between trabecular bone structure parameters computed from PCD-CT data when compared to micro-CT. This suggests that PCD-CT might be useful for analysing bone microstructure in the peripheral human skeleton.
Collapse
Affiliation(s)
- Benjamin Klintström
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, SE-14157, Huddinge, Sweden.
| | - Lilian Henriksson
- Center for Medical Image Science and Visualization (CMIV), Linköping University, SE-58185, Linköping, Sweden.,Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, SE-58185, Linköping, Sweden
| | - Rodrigo Moreno
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, SE-14157, Huddinge, Sweden
| | - Alexandr Malusek
- Center for Medical Image Science and Visualization (CMIV), Linköping University, SE-58185, Linköping, Sweden.,Radiation Physics, Department of Health, Medicine and Caring Sciences, Linköping University, SE-58183, Linköping, Sweden
| | - Örjan Smedby
- Department of Biomedical Engineering and Health Systems, KTH Royal Institute of Technology, Hälsovägen 11C, SE-14157, Huddinge, Sweden
| | - Mischa Woisetschläger
- Center for Medical Image Science and Visualization (CMIV), Linköping University, SE-58185, Linköping, Sweden.,Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, SE-58185, Linköping, Sweden
| | - Eva Klintström
- Center for Medical Image Science and Visualization (CMIV), Linköping University, SE-58185, Linköping, Sweden.,Department of Radiology and Department of Health, Medicine and Caring Sciences, Linköping University, SE-58185, Linköping, Sweden
| |
Collapse
|
9
|
Peña JA, Klein L, Maier J, Damm T, Schlemmer HP, Engelke K, Glüer CC, Kachelrieß M, Sawall S. Dose-efficient assessment of trabecular microstructure using ultra-high-resolution photon-counting CT. Z Med Phys 2022; 32:403-416. [PMID: 35597742 PMCID: PMC9948845 DOI: 10.1016/j.zemedi.2022.04.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2022] [Revised: 03/17/2022] [Accepted: 04/03/2022] [Indexed: 01/23/2023]
Abstract
Photon-counting (PC) detectors for clinical computed tomography (CT) may offer improved imaging capabilities compared to conventional energy-integrating (EI) detectors, e.g. superior spatial resolution and detective efficiency. We here investigate if PCCT can reduce the administered dose in examinations aimed at quantifying trabecular bone microstructure. Five human vertebral bodies were scanned three times in an abdomen phantom (QRM, Germany) using an experimental dual-source CT (Somatom CounT, Siemens Healthineers, Germany) housing an EI detector (0.60 mm pixel size at the iso-center) and a PC detector (0.25 mm pixel size). A tube voltage of 120 kV was used. Tube current-time product for EICT was 355 mAs (23.8 mGy CTDI32 cm). Dose-matched UHR-PCCT (UHRdm, 23.8 mGy) and noise-matched acquisitions (UHRnm, 10.5 mGy) were performed and reconstructed to a voxel size of 0.156 mm using a sharp kernel. Measurements of bone mineral density (BMD) and trabecular separation (Tb.Sp) and Tb.Sp percentiles reflecting the different scales of the trabecular interspacing were performed and compared to a gold-standard measurement using a peripheral CT device (XtremeCT, SCANCO Medical, Switzerland) with an isotropic voxel size of 0.082 mm and 6.6 mGy CTDI10 cm. The image noise was quantified and the relative error with respect to the gold-standard along with the agreement between CT protocols using Lin's concordance correlation coefficient (rCCC) were calculated. The Mean ± StdDev of the measured image noise levels in EICT was 109.6 ± 3.9 HU. UHRdm acquisitions (same dose as EICT) showed a significantly lower noise level of 78.6 ± 4.6 HU (p = 0.0122). UHRnm (44% dose of EICT) showed a noise level of 115.8 ± 3.7 HU, very similar to EICT at the same spatial resolution. For BMD the overall Mean ± StdDev for EI, UHRdm and UHRnm were 114.8 ± 28.6 mgHA/cm3, 121.6 ± 28.8 mgHA/cm3 and 121.5 ± 28.6 mgHA/cm3, respectively, compared to 123.1 ± 25.5 mgHA/cm3 for XtremeCT. For Tb.Sp these values were 1.86 ± 0.54 mm, 1.80 ± 0.56 mm and 1.84 ± 0.52 mm, respectively, compared to 1.66 ± 0.48 mm for XtremeCT. The ranking of the vertebrae with regard to Tb.Sp data was maintained throughout all Tb.Sp percentiles and among the CT protocols and the gold-standard. The agreement between protocols was very good for all comparisons: UHRnm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.998), UHRnm vs. UHRdm (BMD rCCC = 0.998; Tb.Sp rCCC = 0.993) and UHRdm vs. EICT (BMD rCCC = 0.97; Tb.Sp rCCC = 0.991). Consequently, the relative RMS-errors from linear regressions against the gold-standard for EICT, UHRdm and UHRnm were very similar for BMD (7.1%, 5.2% and 5.4%) and for Tb.Sp (3.3%, 3.3% and 2.9%), with a much lower radiation dose for UHRnm. Short-term reproducibility for BMD measurements was similar and below 0.2% for all protocols, but for Tb.Sp showed better results for UHR (about 1/3 of the level for EICT). In conclusion, CT with UHR-PC detectors demonstrated lower image noise and better reproducibility for assessments of bone microstructure at similar dose levels. For UHRnm, radiation exposure levels could be reduced by 56% without deterioration of performance levels in the assessment of bone mineral density and bone microstructure.
Collapse
Affiliation(s)
- Jaime A Peña
- Section Biomedical Imaging, Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Am Botanischen Garten 14, 24118 Kiel, Germany.
| | - Laura Klein
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Department of Physics and Astronomy, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 226, 69120 Heidelberg, Germany
| | - Joscha Maier
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Timo Damm
- Section Biomedical Imaging, Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Am Botanischen Garten 14, 24118 Kiel, Germany
| | - Heinz-Peter Schlemmer
- Radiology, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany
| | - Klaus Engelke
- Institute of Medical Physics, Friedrich-Alexander University Erlangen-Nürnberg, Henkestraße 91, 91052 Erlangen, Germany; Department of Medicine 3, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Claus-Christian Glüer
- Section Biomedical Imaging, Department of Radiology and Neuroradiology, University Hospital Schleswig-Holstein, Am Botanischen Garten 14, 24118 Kiel, Germany
| | - Marc Kachelrieß
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany
| | - Stefan Sawall
- Division of X-Ray Imaging and CT, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120 Heidelberg, Germany; Medical Faculty, Ruprecht-Karls-University Heidelberg, Im Neuenheimer Feld 672, 69120 Heidelberg, Germany
| |
Collapse
|
10
|
Guha I, Zhang X, Rajapakse CS, Chang G, Saha PK. Finite element analysis of trabecular bone microstructure using CT imaging and continuum mechanical modelling. Med Phys 2022; 49:3886-3899. [PMID: 35319784 PMCID: PMC9325403 DOI: 10.1002/mp.15629] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/09/2022] [Accepted: 03/11/2022] [Indexed: 11/16/2022] Open
Abstract
Purpose Osteoporosis is a bone disease associated with enhanced bone loss, microstructural degeneration, and fracture‐risk. Finite element (FE) modeling is used to estimate trabecular bone (Tb) modulus from high‐resolution three‐dimensional (3‐D) imaging modalities including micro‐computed tomography (CT), magnetic resonance imaging (MRI), and high‐resolution peripheral quantitative CT (HR‐pQCT). This paper validates an application of voxel‐based continuum finite element analysis (FEA) to predict Tb modulus from clinical CT imaging under a condition similar to in vivo imaging by comparing with measures derived by micro‐CT and experimental approaches. Method Voxel‐based continuum FEA methods for CT imaging were implemented using linear and nonlinear models and applied on distal tibial scans under a condition similar to in vivo imaging. First, tibial axis in a CT scan was aligned with the coordinate z‐axis at 150 μm isotropic voxels. FEA was applied on an upright cylindrical volume of interests (VOI) with its axis coinciding with the tibial bone axis. Voxel volume, edge, and vertex elements and their connectivity were defined as per the isotropic image grid. A calibration phantom was used to calibrate CT numbers in Hounsfield unit to bone mineral density (BMD) values, which was then converted into calcium hydroxyapatite (CHA) density. Mechanical properties at each voxel volume element was defined using its ash‐density defined on CT‐derived CHA density. For FEA, the bottom surface of the cylindrical VOI was fixed and a constant displacement was applied along the z‐direction at each vertex element on the top surface to simulate a physical axial compressive loading condition. Finally, a Poisson's ratio of 0.3 was applied, and Tb modulus (MPa) was computed as the ratio of average von Mises stress (MPa) of volume elements on the top surface and the applied displacement. FEA parameters including mesh element size, substep number, and different tolerance values were optimized. Results CT‐derived Tb modulus values using continuum FEA showed high linear correlation with the micro‐CT‐derived reference values (r ∈ [0.87 0.90]) as well as experimentally measured values (r ∈ [0.80 0.87]). Linear correlation of computed modulus with their reference values using continuum FEA with linear modeling was comparable with that obtained by nonlinear modeling. Nonlinear continuum FEA‐based modulus values (mean of 1087.2 MPa) showed greater difference from their reference values (mean of 1498.9 MPa using micro‐CT‐based FEA) as compared with linear continuum methods. High repeat CT scan reproducibility (intra‐class correlation [ICC] = 0.98) was observed for computed modulus values using both linear and nonlinear continuum FEA. It was observed that high stress regions coincide with Tb microstructure as fuzzily characterized by BMD values. Distributions of von Mises stress over Tb microstructure and marrow regions were significantly different (p < 10–8). Conclusion Voxel‐based continuum FEA offers surrogate measures of Tb modulus from CT imaging under a condition similar to in vivo imaging that alleviates the need for segmentation of Tb and marrow regions, while accounting for bone distribution at the microstructural level. This relaxation of binary segmentation will extend the scope of FEA application to assess mechanical properties of bone microstructure at relatively low‐resolution imaging.
Collapse
Affiliation(s)
- Indranil Guha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, 52242, USA
| | - Xiaoliu Zhang
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, 52242, USA
| | - Chamith S Rajapakse
- Departments of Radiology and Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, 19104, USA
| | - Gregory Chang
- Department of Radiology, New York University Grossman School of Medicine, New York, NY, 10016, USA
| | - Punam K Saha
- Department of Electrical and Computer Engineering, College of Engineering, University of Iowa, Iowa City, IA, 52242, USA.,Department of Radiology, Carver College of Medicine, University of Iowa, Iowa City, IA, 52242, USA
| |
Collapse
|
11
|
Sinzinger F, van Kerkvoorde J, Pahr DH, Moreno R. Predicting the trabecular bone apparent stiffness tensor with spherical convolutional neural networks. Bone Rep 2022; 16:101179. [PMID: 35309107 PMCID: PMC8927924 DOI: 10.1016/j.bonr.2022.101179] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 02/15/2022] [Accepted: 03/03/2022] [Indexed: 12/14/2022] Open
Abstract
The apparent stiffness tensor is relevant for characterizing trabecular bone quality. Previous studies have used morphology-stiffness relationships for estimating the apparent stiffness tensor. In this paper, we propose to train spherical convolutional neural networks (SphCNNs) to estimate this tensor. Information of the edges, trabecular thickness, and spacing are summarized in functions on the unitary sphere used as inputs for the SphCNNs. The concomitant dimensionality reduction makes it possible to train neural networks on relatively small datasets. The predicted tensors were compared to the stiffness tensors computed by using the micro-finite element method (μFE), which was considered as the gold standard, and models based on fourth-order fabric tensors. Combining edges and trabecular thickness yields significant improvements in the accuracy compared to the methods based on fourth-order fabric tensors. From the results, SphCNNs are promising for replacing the more expensive μFE stiffness estimations. Characteristic stiffness tensors are derived from trabecular bone micro-CT samples. Previous approximation methods fall short on heterogeneous data-sets. The gradient, trabecular thickness and spacing are mapped to a spherical domain. Spherical convolutional neural networks are used for the prediction. The prediction error is significantly reduced compared to the state-of-the-art.
Collapse
|
12
|
Jin D, Zheng H, Zhao Q, Wang C, Zhang M, Yuan H. Generation of Vertebra Micro-CT-like Image from MDCT: A Deep-Learning-Based Image Enhancement Approach. Tomography 2021; 7:767-782. [PMID: 34842849 PMCID: PMC8628970 DOI: 10.3390/tomography7040064] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Revised: 11/05/2021] [Accepted: 11/09/2021] [Indexed: 11/26/2022] Open
Abstract
This paper proposes a deep-learning-based image enhancement approach that can generate high-resolution micro-CT-like images from multidetector computed tomography (MDCT). A total of 12,500 MDCT and micro-CT image pairs were obtained from 25 vertebral specimens. Then, a pix2pixHD model was trained and evaluated using the structural similarity index measure (SSIM) and Fréchet inception distance (FID). We performed subjective assessments of the micro-CT-like images based on five aspects. Micro-CT and micro-CT-like image-derived trabecular bone microstructures were compared, and the underlying correlations were analyzed. The results showed that the pix2pixHD method (SSIM, 0.804 ± 0.037 and FID, 43.598 ± 9.108) outperformed the two control methods (pix2pix and CRN) in enhancing MDCT images (p < 0.05). According to the subjective assessment, the pix2pixHD-derived micro-CT-like images showed no significant difference from the micro-CT images in terms of contrast and shadow (p > 0.05) but demonstrated slightly lower noise, sharpness and trabecular bone texture (p < 0.05). Compared with the trabecular microstructure parameters of micro-CT images, those of pix2pixHD-derived micro-CT-like images showed no significant differences in bone volume fraction (BV/TV) (p > 0.05) and significant correlations in trabecular thickness (Tb.Th) and trabecular spacing (Tb.Sp) (Tb.Th, R = 0.90, p < 0.05; Tb.Sp, R = 0.88, p < 0.05). The proposed method can enhance the resolution of MDCT and obtain micro-CT-like images, which may provide new diagnostic criteria and a predictive basis for osteoporosis and related fractures.
Collapse
Affiliation(s)
- Dan Jin
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Han Zheng
- School of Traffic and Transportation, Beijing Jiaotong University, Beijing 100044, China;
| | - Qingqing Zhao
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Chunjie Wang
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Mengze Zhang
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
| | - Huishu Yuan
- Department of Radiology, Peking University Third Hospital, Beijing 100191, China; (D.J.); (Q.Z.); (C.W.); (M.Z.)
- Correspondence:
| |
Collapse
|