1
|
Akbari F, Liu X, Hamedi F, Mohtasebi M, Chen L, Chen L, Yu G. Programmable scanning diffuse speckle contrast imaging of cerebral blood flow. NEUROPHOTONICS 2025; 12:015006. [PMID: 39872020 PMCID: PMC11770344 DOI: 10.1117/1.nph.12.1.015006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/19/2024] [Revised: 12/19/2024] [Accepted: 01/06/2025] [Indexed: 01/29/2025]
Abstract
Significance Cerebral blood flow (CBF) imaging is crucial for diagnosing cerebrovascular diseases. However, existing large neuroimaging techniques with high cost, low sampling rate, and poor mobility make them unsuitable for continuous and longitudinal CBF monitoring at the bedside. Aim We aimed to develop a low-cost, portable, programmable scanning diffuse speckle contrast imaging (PS-DSCI) technology for fast, high-density, and depth-sensitive imaging of CBF in rodents. Approach The PS-DSCI employed a programmable digital micromirror device (DMD) for remote line-shaped laser (785 nm) scanning on tissue surface and synchronized a 2D camera for capturing boundary diffuse laser speckle contrasts. New algorithms were developed to address deformations of line-shaped scanning, thus minimizing CBF reconstruction artifacts. The PS-DSCI was examined in head-simulating phantoms and adult mice. Results The PS-DSCI enables resolving intralipid particle flow contrasts at different tissue depths. In vivo experiments in adult mice demonstrated the capability of PS-DSCI to image global/regional CBF variations induced by 8%CO 2 inhalation and transient carotid artery ligations. Conclusions Compared with conventional point scanning, line scanning in PS-DSCI significantly increases spatiotemporal resolution. The high sampling rate of PS-DSCI is crucial for capturing rapid CBF changes while high spatial resolution is important for visualizing brain vasculature.
Collapse
Affiliation(s)
- Faezeh Akbari
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Xuhui Liu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Fatemeh Hamedi
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Mehrana Mohtasebi
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Li Chen
- University of Kentucky, Biostatistics and Bioinformatics Shared Resource Facility, Markey Cancer Center, Lexington, Kentucky, United States
| | - Lei Chen
- University of Kentucky, Spinal Cord and Brain Injury Research Center, Department of Physiology, Lexington, Kentucky, United States
| | - Guoqiang Yu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| |
Collapse
|
2
|
Mohtasebi M, Singh D, Liu X, Fathi F, Haratbar SR, Saatman KE, Chen L, Yu G. Depth-sensitive diffuse speckle contrast topography for high-density mapping of cerebral blood flow in rodents. NEUROPHOTONICS 2023; 10:045007. [PMID: 38076725 PMCID: PMC10704187 DOI: 10.1117/1.nph.10.4.045007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 10/26/2023] [Accepted: 10/27/2023] [Indexed: 02/12/2024]
Abstract
Significance Frequent assessment of cerebral blood flow (CBF) is crucial for the diagnosis and management of cerebral vascular diseases. In contrast to large and expensive imaging modalities, such as nuclear medicine and magnetic resonance imaging, optical imaging techniques are portable and inexpensive tools for continuous measurements of cerebral hemodynamics. The recent development of an innovative noncontact speckle contrast diffuse correlation tomography (scDCT) enables three-dimensional (3D) imaging of CBF distributions. However, scDCT requires complex and time-consuming 3D reconstruction, which limits its ability to achieve high spatial resolution without sacrificing temporal resolution and computational efficiency. Aim We investigate a new diffuse speckle contrast topography (DSCT) method with parallel computation for analyzing scDCT data to achieve fast and high-density two-dimensional (2D) mapping of CBF distributions at different depths without the need for 3D reconstruction. Approach A new moving window method was adapted to improve the sampling rate of DSCT. A fast computation method utilizing MATLAB functions in the Image Processing Toolbox™ and Parallel Computing Toolbox™ was developed to rapidly generate high-density CBF maps. The new DSCT method was tested for spatial resolution and depth sensitivity in head-simulating layered phantoms and in-vivo rodent models. Results DSCT enables 2D mapping of the particle flow in the phantom at different depths through the top layer with varied thicknesses. Both DSCT and scDCT enable the detection of global and regional CBF changes in deep brains of adult rats. However, DSCT achieves fast and high-density 2D mapping of CBF distributions at different depths without the need for complex and time-consuming 3D reconstruction. Conclusions The depth-sensitive DSCT method has the potential to be used as a noninvasive, noncontact, fast, high resolution, portable, and inexpensive brain imager for basic neuroscience research in small animal models and for translational studies in human neonates.
Collapse
Affiliation(s)
- Mehrana Mohtasebi
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Dara Singh
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Xuhui Liu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | - Faraneh Fathi
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| | | | - Kathryn E. Saatman
- University of Kentucky, Spinal Cord and Brain Injury Research Center, Department of Physiology, Lexington, Kentucky, United States
| | - Lei Chen
- University of Kentucky, Spinal Cord and Brain Injury Research Center, Department of Physiology, Lexington, Kentucky, United States
| | - Guoqiang Yu
- University of Kentucky, Department of Biomedical Engineering, Lexington, Kentucky, United States
| |
Collapse
|
3
|
Zhou W, Zhao M, Srinivasan VJ. Interferometric diffuse optics: recent advances and future outlook. NEUROPHOTONICS 2023; 10:013502. [PMID: 36284601 PMCID: PMC9587754 DOI: 10.1117/1.nph.10.1.013502] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Accepted: 09/26/2022] [Indexed: 06/16/2023]
Abstract
The field of diffuse optics has provided a rich set of neurophotonic tools to measure the human brain noninvasively. Interferometric detection is a recent, exciting methodological development in this field. The approach is especially promising for the measurement of diffuse fluctuation signals related to blood flow. Benefitting from inexpensive sensor arrays, the interferometric approach has already dramatically improved throughput, enabling the measurement of brain blood flow faster and deeper. The interferometric approach can also achieve time-of-flight resolution, improving the accuracy of acquired signals. We provide a historical perspective and summary of recent work in the nascent area of interferometric diffuse optics. We predict that the convergence of interferometric technology with existing economies of scale will propel many advances in the years to come.
Collapse
Affiliation(s)
- Wenjun Zhou
- China Jiliang University, College of Optical and Electronic Technology, Hangzhou, China
- University of California Davis, Department of Biomedical Engineering, Davis, California, United States
| | - Mingjun Zhao
- University of California Davis, Department of Biomedical Engineering, Davis, California, United States
- New York University Langone Health, Department of Radiology, New York, New York, United States
| | - Vivek J. Srinivasan
- University of California Davis, Department of Biomedical Engineering, Davis, California, United States
- New York University Langone Health, Department of Radiology, New York, New York, United States
- New York University Langone Health, Department of Ophthalmology, New York, New York, United States
- New York University Langone Health, Tech4Health Institute, New York, New York, United States
| |
Collapse
|
4
|
Intraoperative Optical and Fluorescence Imaging of Blood Flow Distributions in Mastectomy Skin Flaps for Identifying Ischemic Tissues. Plast Reconstr Surg 2022; 150:282-287. [PMID: 35653513 PMCID: PMC9334221 DOI: 10.1097/prs.0000000000009333] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/03/2023]
Abstract
SUMMARY Insufficient blood flow causes mastectomy skin flap necrosis in 5 to 30 percent of cases. Fluorescence angiography with the injection of indocyanine green dye has shown high sensitivities (90 to 100 percent) but moderate specificities (72 to 50 percent) in predicting mastectomy skin flap necrosis. However, a number of challenging issues limit its wide acceptance in clinical settings, including allergic reaction, short time-window for observation, and high cost for equipment and supplies. An emerging inexpensive speckle contrast diffuse correlation tomography technology enables noninvasive, noncontact, and continuous three-dimensional imaging of blood flow distributions in deep tissues. This preliminary study tested the hypothesis that speckle contrast diffuse correlation tomography and indocyanine green-fluorescence angiography measurements of blood flow distributions in mastectomy skin flaps are consistent. Eleven female patients undergoing skin-sparing or nipple-sparing mastectomies were imaged sequentially by the dye-free speckle contrast diffuse correlation tomography and dye-based commercial fluorescence angiography (SPY-PHI). Resulting images from these two imaging modalities were co-registered based on the ischemic areas with the lowest blood flow values. Because the ischemic areas have irregular shapes, a novel contour-based algorithm was used to compare three-dimensional images of blood flow distribution and two-dimensional maps of indocyanine green perfusion. Significant correlations were observed between the two measurements in all contours from a selected area of 10 × 10 mm 2 with the lowest blood flow ( r ≥ 0.78; p < 0.004), suggesting that speckle contrast diffuse correlation tomography provides the information for identifying ischemic tissues in mastectomy skin flaps. With further optimization and validation in large populations, speckle contrast diffuse correlation tomography may ultimately be used as a noninvasive and inexpensive imaging tool for intraoperative assessment of skin flap viability to predict mastectomy skin flap necrosis. CLINICAL QUESTION/LEVEL OF EVIDENCE Diagnostic, II.
Collapse
|
5
|
Zhao M, Huang C, Mazdeyasna S, Yu G. Extraction of tissue optical property and blood flow from speckle contrast diffuse correlation tomography (scDCT) measurements. BIOMEDICAL OPTICS EXPRESS 2021; 12:5894-5908. [PMID: 34692223 PMCID: PMC8515985 DOI: 10.1364/boe.429890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Revised: 07/15/2021] [Accepted: 08/17/2021] [Indexed: 06/13/2023]
Abstract
Measurement of blood flow in tissue provides vital information for the diagnosis and therapeutic monitoring of various vascular diseases. A noncontact, camera-based, near-infrared speckle contrast diffuse correlation tomography (scDCT) technique has been recently developed for 3D imaging of blood flow index (αDB) distributions in deep tissues up to a centimeter. A limitation with the continuous-wave scDCT measurement of blood flow is the assumption of constant and homogenous tissue absorption coefficient (μ a ). The present study took the advantage of rapid, high-density, noncontact scDCT measurements of both light intensities and diffuse speckle contrast at multiple source-detector distances and developed two-step fitting algorithms for extracting both μ a and αDB. The new algorithms were tested in tissue-simulating phantoms with known optical properties and human forearms. Measurement results were compared against established near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS) techniques. The accuracies of our new fitting algorithms with scDCT measurements in phantoms (up to 16% errors) and forearms (up to 23% errors) are comparable to relevant study results (up to 25% errors). Knowledge of μ a not only improved the accuracy in calculating αDB but also provided the potential for quantifying tissue blood oxygenation via spectral measurements. A multiple-wavelength scDCT system with new algorithms is currently developing to fit multi-wavelength and multi-distance data for 3D imaging of both blood flow and oxygenation distributions in deep tissues.
Collapse
|
6
|
Huang C, Mazdeyasna S, Mohtasebi M, Saatman KE, Cheng Q, Yu G, Chen L. Speckle contrast diffuse correlation tomography of cerebral blood flow in perinatal disease model of neonatal piglets. JOURNAL OF BIOPHOTONICS 2021; 14:e202000366. [PMID: 33295142 PMCID: PMC8833087 DOI: 10.1002/jbio.202000366] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 12/05/2020] [Accepted: 12/06/2020] [Indexed: 05/11/2023]
Abstract
We adapted and tested an innovative noncontact speckle contrast diffuse correlation tomography (scDCT) system for 3D imaging of cerebral blood flow (CBF) variations in perinatal disease models utilizing neonatal piglets, which closely resemble human neonates. CBF variations were concurrently measured by the scDCT and an established diffuse correlation spectroscopy (DCS) during global ischemia, intraventricular hemorrhage, and asphyxia; significant correlations were observed. Moreover, CBF variations associated reasonably with vital pathophysiological changes. In contrast to DCS measurements of mixed signals from local scalp, skull and brain, scDCT generates 3D images of CBF distributions at prescribed depths within the head, thus enabling specific determination of regional cerebral ischemia. With further optimization and validation in animals and human neonates, scDCT has the potential to be a noninvasive imaging tool for both basic neuroscience research in laboratories and clinical applications in neonatal intensive care units.
Collapse
Affiliation(s)
- Chong Huang
- Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky
| | - Siavash Mazdeyasna
- Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky
| | - Mehrana Mohtasebi
- Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky
| | - Kathryn E. Saatman
- Department of Physiology, Spinal Cord and Brain Injury Research Center, University of Kentucky, Lexington, Kentucky
| | - Qiang Cheng
- Division of Biomedical Informatics, Department of Internal Medicine, University of Kentucky, Lexington, Kentucky
| | - Guoqiang Yu
- Department of Biomedical Engineering, University of Kentucky, Lexington, Kentucky
| | - Lei Chen
- Department of Physiology, Spinal Cord and Brain Injury Research Center, University of Kentucky, Lexington, Kentucky
| |
Collapse
|