1
|
Velikova T, Mileva N, Naseva E. Method “Monte Carlo” in healthcare. World J Methodol 2024; 14:93930. [DOI: 10.5662/wjm.v14.i3.93930] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2024] [Revised: 05/12/2024] [Accepted: 05/27/2024] [Indexed: 06/25/2024] Open
Abstract
In public health, simulation modeling stands as an invaluable asset, enabling the evaluation of new systems without their physical implementation, experimentation with existing systems without operational adjustments, and testing system limits without real-world repercussions. In simulation modeling, the Monte Carlo method emerges as a powerful yet underutilized tool. Although the Monte Carlo method has not yet gained widespread prominence in healthcare, its technological capabilities hold promise for substantial cost reduction and risk mitigation. In this review article, we aimed to explore the transformative potential of the Monte Carlo method in healthcare contexts. We underscore the significance of experiential insights derived from simulated experimentation, especially in resource-constrained scenarios where time, financial constraints, and limited resources necessitate innovative and efficient approaches. As public health faces increasing challenges, incorporating the Monte Carlo method presents an opportunity for enhanced system construction, analysis, and evaluation.
Collapse
Affiliation(s)
- Tsvetelina Velikova
- Medical Faculty, Sofia University St. Kliment Ohridski, Sofia 1407, Bulgaria
| | - Niya Mileva
- Medical Faculty, Medical University of Sofia, Sofia 1431, Bulgaria
| | - Emilia Naseva
- Faculty of Public Health “Prof. Tsekomir Vodenicharov, MD, Dsc,” Medical University of Sofia, Sofia 1431, Bulgaria
| |
Collapse
|
2
|
Li B, Huang J, Ruan J, Peng Q, Huang S, Li Y, Li F. Dosimetric impact of CT metal artifact reduction for spinal implants in stereotactic body radiotherapy planning. Quant Imaging Med Surg 2023; 13:8290-8302. [PMID: 38106297 PMCID: PMC10721987 DOI: 10.21037/qims-23-442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 09/14/2023] [Indexed: 12/19/2023]
Abstract
Background Metal artifacts due to spinal implants may affect the accuracy of dose calculation for radiotherapy. However, the dosimetric impact of metal artifact reduction (MAR) for spinal implants in stereotactic body radiotherapy (SBRT) plans has not been well studied. The objective of this study was to evaluate the dosimetric impact of MAR in spinal SBRT planning with three clinically common dose calculation algorithms. Methods Gammex phantom and 10 patients' computed tomography (CT) images were studied to investigate the effects of titanium implants. A commercial orthopedic MAR algorithm was employed to reduce artifacts. Dose calculations for SBRT were conducted on both artifact-corrected and uncorrected images using three commercial algorithms [analytical anisotropic algorithm (AAA), Acuros XB (AXB), and Monte Carlo (MC)]. Dose discrepancies between artifact-corrected and uncorrected cases were appraised using a dose-volume histogram (DVH) and 3-dimensional (3D) gamma analysis with different distance to agreement (DTA) and dose difference criteria. The gamma agreement index (GAI) was denoted as G(∆D, DTA). Statistical analysis of t-test was utilized to evaluate the dose differences of different algorithms. Results The phantom study demonstrated that titanium metal artifacts can be effectively reduced. The patient cases study showed that dose differences between the artifact-corrected and uncorrected datasets were small evaluated by gamma index and DVH. Gamma analysis found that even the strict criterion local G(1,1) had average values ≥93.9% for the three algorithms. For all DVH metrics, average differences did not exceed 0.7% in planning target volume (PTV) and 2.1% in planning risk volume of spinal cord (PRV-SC). Statistical analysis showed that the observed dose differences of MC method were significantly larger than those of AAA (P<0.01 for D98% of PTV and P<0.001 for D0.1cc of spinal cord) and AXB methods (P<0.001 for D98% and P<0.0001 for D0.1cc). Conclusions Dosimetric impact of artifacts caused by titanium implants is not significant in spinal SBRT planning, which indicates that dose calculation algorithms might not be very sensitive to CT number variation caused by titanium inserts.
Collapse
Affiliation(s)
- Bin Li
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Jiexing Huang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
- Department of Radiation Oncology, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, China
| | - Junjie Ruan
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Qinghe Peng
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Sijuan Huang
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Yunfei Li
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| | - Fanghua Li
- State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Sun Yat-sen University Cancer Center, Guangzhou, China
| |
Collapse
|
3
|
Wei R, Liu Y, Chen X, Zhu J, Yang B, Men K, Dai J. A projection-domain correction method in CBCT reconstruction for head and neck radiotherapy using cycle-GAN and nonlocal means filter. Med Phys 2023; 50:5045-5060. [PMID: 37006163 DOI: 10.1002/mp.16322] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 02/08/2023] [Accepted: 02/08/2023] [Indexed: 04/04/2023] Open
Abstract
BACKGROUND In radiation treatments for head and neck tumors, cone-beam computed tomography (CBCT) is employed for patient positioning and dose calculation of adaptive radiotherapy. However, the quality of CBCT is degraded by the scatter and noise, majorly impacting the accuracy of patient positioning and dose calculation. PURPOSE To improve the quality of CBCT for patients with head and neck cancer, a projection-domain CBCT correction method was proposed using a cycle-consistent generative adversarial network (cycle-GAN) and a nonlocal means filter (NLMF) based on a reference digitally reconstructed radiograph (DRR). METHODS A cycle-GAN was initially trained to learn mapping from CBCT projections to a DRR using the data obtained from 30 patients. For each patient, 671 CBCT projections were measured for CBCT reconstruction. Moreover, 360 Digital Reconstructed Radiographs (DRR) were computed from each patient's planning computed tomography (CT), whose projection angles ranged from 0° to 359° with an interval of 1°. By applying the trained generator of the cycle-GAN to the unseen CBCT projection, a synthetic DRR with considerably less scatter was obtained. However, annular artifacts were observed in the CBCT reconstructed with synthetic DRR. To address this issue, a NLMF based on reference DRR was used to further correct the synthetic DRR, which corrected the synthetic DRR using the calculated DRR as a reference image. Finally, the CBCT with no annular artifact and little noise was reconstructed with the corrected synthetic DRR. The proposed method was tested using the data of six patients. The corrected synthetic DRR and CBCT were compared with the corresponding real DRR and CT images. The structural preservation ability of the proposed method was evaluated using the Dice coefficients of the automatically extracted nasal cavity. Moreover, the image quality of CBCT corrected with the proposed method was objectively assessed with an five-point human scoring system and compared with CT, original CBCT and CBCT corrected with other strategies. RESULTS The mean absolute value (MAE) of the relative error between the corrected synthetic and real DRR was <8%. The MAE between the corrected CBCT and corresponding CT was <30 HU. Moreover, the Dice coefficient of nasal cavity between the corrected CBCT image and the original image exceeded 98.8 for all the patients. Last but not least, the objective assessment of image quality showed the proposed method had an average score of 4.2 in overall image quality, which was higher than that of the original CBCT, CBCT reconstructed with synthetic DRR, and CBCT reconstructed with projections filtered with NLMF only. CONCLUSIONS The proposed method can considerably improve the CBCT image quality with little anatomical distortion, improving the accuracy of radiotherapy for head and neck patients.
Collapse
Affiliation(s)
- Ran Wei
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- National Cancer Center/National Clinical Research Center for Cancer/Hebei Cancer Hospital, Chinese Academy of Medical Sciences, Langfang, China
| | - Yuxiang Liu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Xinyuan Chen
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- National Cancer Center/National Clinical Research Center for Cancer/Hebei Cancer Hospital, Chinese Academy of Medical Sciences, Langfang, China
| | - Ji Zhu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Bining Yang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Kuo Men
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Jianrong Dai
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| |
Collapse
|
4
|
Ounoughi N, Boukhellout A, Kharfi F. Neutron shielding assessment of a 16O hadron therapy room by means of Monte Carlo simulations with the PHITS code. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2023; 43:011506. [PMID: 36599152 DOI: 10.1088/1361-6498/acaff0] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Accepted: 01/04/2023] [Indexed: 06/17/2023]
Abstract
Hadron radiation therapy is of great interest worldwide. Heavy-ion beams provide ideal therapeutic conditions for deep-seated local tumours. At the Heidelberg Ion Beam Therapy Center (HIT, Germany), protons and carbon ions are already integrated into the clinical routine, while16O ions are still used for research only. To ensure the protection of the technical staff and members of the public, it is required to estimate the neutron dose distribution for optimal working conditions and at different locations. The Particle and Heavy Ion Transport Code System (PHITS) is used in this work to evaluate the dose rate distribution of secondary neutrons in a treatment room at HIT where16O ions are used: an equivalent target in soft tissue is considered in the shielding assessment to simulate the interaction of the beam with patients. The angular dependence of neutron fluences and energy spectra around the considered phantom were calculated. Alongside the spatial distribution of the neutron and photon fluence, a map of the effective dose rate was estimated using the ICRP fluence-to-effective dose conversion coefficients, exploiting the PHITS code's built-in capabilities. The capability of the actual shielding design of the studied HIT treatment room was approved.
Collapse
Affiliation(s)
- Nabil Ounoughi
- Radiation Physics and Applications Laboratory, Mohammed Seddik Benyahia University, Jijel, Algeria
| | - Abdelmalek Boukhellout
- Radiation Physics and Applications Laboratory, Mohammed Seddik Benyahia University, Jijel, Algeria
| | - Faycal Kharfi
- Laboratory of Dosing, Analysis and Characterization in High Resolution (DAC), Ferhat Abbas Setif1 University, Setif, Algeria
| |
Collapse
|
5
|
Monte-Carlo techniques for radiotherapy applications II: equipment and source modelling, dose calculations and radiobiology. JOURNAL OF RADIOTHERAPY IN PRACTICE 2023. [DOI: 10.1017/s1460396923000080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2023]
Abstract
Abstract
Introduction:
This is the second of two papers giving an overview of the use of Monte-Carlo techniques for radiotherapy applications.
Methods:
The first paper gave an introduction and introduced some of the codes that are available to the user wishing to model the different aspects of radiotherapy treatment. It also aims to serve as a useful companion to a curated collection of papers on Monte-Carlo that have been published in this journal.
Results and Conclusions:
This paper focuses on the application of Monte-Carlo to specific problems in radiotherapy. These include radiotherapy and imaging beam production, brachytherapy, phantom and patient dosimetry, detector modelling and track structure calculations for micro-dosimetry, nano-dosimetry and radiobiology.
Collapse
|
6
|
Piruzan E, Vosoughi N, Mahani H. Modeling and optimization of respiratory-gated partial breast irradiation with proton beams - A Monte Carlo study. Comput Biol Med 2022; 147:105666. [DOI: 10.1016/j.compbiomed.2022.105666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 04/24/2022] [Accepted: 05/21/2022] [Indexed: 11/03/2022]
|
7
|
Barnes MP, Sun B, Oborn BM, Lamichhane B, Szwec S, Schmidt M, Cai B, Menk F, Greer P. Determination of the electronic portal imaging device pixel‐sensitivity‐map for quality assurance applications. Part 1: Comparison of methods. J Appl Clin Med Phys 2022; 23:e13603. [PMID: 35429102 PMCID: PMC9195035 DOI: 10.1002/acm2.13603] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 03/08/2022] [Accepted: 03/15/2022] [Indexed: 11/06/2022] Open
Abstract
Purpose Methods Results Conclusion
Collapse
Affiliation(s)
- Michael Paul Barnes
- Department of Radiation Oncology Calvary Mater Hospital Newcastle Newcastle New South Wales Australia
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| | - Baozhou Sun
- Department of Radiation Oncology Washington University in St. Louis St. Louis Missouri USA
| | - Brad Michael Oborn
- Centre for Medical Radiation Physics University of Wollongong Wollongong New South Wales Australia
- Illawarra Cancer Care Centre Wollongong Hospital Wollongong New South Wales Australia
| | - Bishnu Lamichhane
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| | - Stuart Szwec
- School of Medicine and Public Health University of Newcastle Newcastle New South Wales Australia
| | - Matthew Schmidt
- Department of Radiation Oncology Washington University in St. Louis St. Louis Missouri USA
| | - Bin Cai
- Department of Radiation Oncology Washington University in St. Louis St. Louis Missouri USA
| | - Frederick Menk
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| | - Peter Greer
- Department of Radiation Oncology Calvary Mater Hospital Newcastle Newcastle New South Wales Australia
- School of Mathematical and Physical Sciences University of Newcastle Newcastle New South Wales Australia
| |
Collapse
|
8
|
Götz S, Dickmann J, Rit S, Krah N, Khellaf F, Schulte RW, Parodi K, Dedes G, Landry G. Evaluation of the impact of a scanner prototype on proton CT and helium CT image quality and dose efficiency with Monte Carlo simulation. Phys Med Biol 2022; 67. [PMID: 35086073 DOI: 10.1088/1361-6560/ac4fa4] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Accepted: 01/27/2022] [Indexed: 11/12/2022]
Abstract
Objective.The use of ion computed tomography (CT) promises to yield improved relative stopping power (RSP) estimation as input to particle therapy treatment planning. Recently, proton CT (pCT) has been shown to yield RSP accuracy on par with state-of-the-art x-ray dual energy CT. There are however concerns that the lower spatial resolution of pCT compared to x-ray CT may limit its potential, which has spurred interest in the use of helium ion CT (HeCT). The goal of this study was to investigate image quality of pCT and HeCT in terms of noise, spatial resolution, RSP accuracy and imaging dose using a detailed Monte Carlo (MC) model of an existing ion CT prototype.Approach.Three phantoms were used in simulated pCT and HeCT scans allowing estimation of noise, spatial resolution and the scoring of dose. An additional phantom was used to evaluate RSP accuracy. The imaging dose required to achieve the same image noise in a water and a head phantom was estimated at both native spatial resolution, and in a scenario where the HeCT spatial resolution was reduced and matched to that of pCT using Hann windowing of the reconstruction filter. A variance reconstruction formalism was adapted to account for Hann windowing.Main results.We confirmed that the scanner prototype would produce higher spatial resolution for HeCT than pCT by a factor 1.8 (0.86 lp mm-1versus 0.48 lp mm-1at the center of a 20 cm water phantom). At native resolution, HeCT required a factor 2.9 more dose than pCT to achieve the same noise, while at matched resolution, HeCT required only 38% of the pCT dose. Finally, RSP mean absolute percent error (MAPE) was found to be 0.59% for pCT and 0.67% for HeCT.Significance.This work compared the imaging performance of pCT and HeCT when using an existing scanner prototype, with the spatial resolution advantage of HeCT coming at the cost of increased dose. When matching spatial resolution via Hann windowing, HeCT had a substantial dose advantage. Both modalities provided state-of-the-art RSP MAPE. HeCT might therefore help reduce the dose exposure of patients with comparable image noise to pCT, enhanced spatial resolution and acceptable RSP accuracy at the same time.
Collapse
Affiliation(s)
- S Götz
- Department of Medical Physics, Fakultät für Physik, Ludwig-Maximilians-Universität München (LMU Munich), D-85748 Garching bei München, Germany
| | - J Dickmann
- Department of Medical Physics, Fakultät für Physik, Ludwig-Maximilians-Universität München (LMU Munich), D-85748 Garching bei München, Germany
| | - S Rit
- University of Lyon, INSA-Lyon, Unversité Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS, UMR 5220, U1294 F-69373, Lyon, France
| | - N Krah
- University of Lyon, INSA-Lyon, Unversité Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS, UMR 5220, U1294 F-69373, Lyon, France.,IP2I, UMR 5822 F-69622, Villeurbanne, France
| | - F Khellaf
- University of Lyon, INSA-Lyon, Unversité Claude Bernard Lyon 1, UJM-Saint Etienne, CNRS, Inserm, CREATIS, UMR 5220, U1294 F-69373, Lyon, France
| | - R W Schulte
- Division of Biomedical Engineering Sciences, Loma Linda University, Loma Linda, CA 92354, United States of America
| | - K Parodi
- Department of Medical Physics, Fakultät für Physik, Ludwig-Maximilians-Universität München (LMU Munich), D-85748 Garching bei München, Germany
| | - G Dedes
- Department of Medical Physics, Fakultät für Physik, Ludwig-Maximilians-Universität München (LMU Munich), D-85748 Garching bei München, Germany
| | - G Landry
- Department of Medical Physics, Fakultät für Physik, Ludwig-Maximilians-Universität München (LMU Munich), D-85748 Garching bei München, Germany.,Department of Radiation Oncology, University Hospital, LMU Munich, D-81377 Munich, Germany.,German Cancer Consortium (DKTK), D-81377 Munich, Germany
| |
Collapse
|