Feng X, Muhashi A, Onishi Y, Ota R, Liu H. Transformer-CNN hybrid network for improving PET time of flight prediction. Phys Med Biol 2024; 69:115047. [PMID: 38749457 DOI: 10.1088/1361-6560/ad4c4d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Accepted: 05/15/2024] [Indexed: 05/31/2024]
Abstract
Objective.In positron emission tomography (PET) reconstruction, the integration of time-of-flight (TOF) information, known as TOF-PET, has been a major research focus. Compared to traditional reconstruction methods, the introduction of TOF enhances the signal-to-noise ratio of images. Precision in TOF is measured by full width at half maximum (FWHM) and the offset from ground truth, referred to as coincidence time resolution (CTR) and bias.Approach.This study proposes a network combining transformer and convolutional neural network (CNN) to utilize TOF information from detector waveforms, using event waveform pairs as inputs. This approach integrates the global self-attention mechanism of Transformer, which focuses on temporal relationships, with the local receptive field of CNN. The combination of global and local information allows the network to assign greater weight to the rising edges of waveforms, thereby extracting valuable temporal information for precise TOF predictions. Experiments were conducted using lutetium yttrium oxyorthosilicate (LYSO) scintillators and silicon photomultiplier (SiPM) detectors. The network was trained and tested using the waveform datasets after cropping.Main results.Compared to the constant fraction discriminator (CFD), CNN, CNN with attention, long short-term memory (LSTM) and Transformer, our network achieved an average CTR of 189 ps, reducing it by 82 ps (more than 30%), 13 ps (6.4%), 12 ps (6.0%), 16 ps (7.8%) and 9 ps (4.6%), respectively. Additionally, a reduction of 10.3, 8.7, 6.7 and 4 ps in average bias was achieved compared to CNN, CNN with attention, LSTM and Transformer.Significance.This work demonstrates the potential of applying the Transformer for PET TOF estimation using real experimental data. Through the integration of both CNN and Transformer with local and global attention, it achieves optimal performance, thereby presenting a novel direction for future research in this field.
Collapse
Affiliation(s)
- Xuhui Feng
- The State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Amanjule Muhashi
- The State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| | - Yuya Onishi
- The Central Research Laboratory, Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu 434-8601, Japan
| | - Ryosuke Ota
- The Central Research Laboratory, Hamamatsu Photonics K.K., 5000 Hirakuchi, Hamakita-ku, Hamamatsu 434-8601, Japan
| | - Huafeng Liu
- The State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou 310027, People's Republic of China
| |
Collapse
|
2
|
Piller M, Castilla AM, Terragni G, Alozy J, Auffray E, Ballabriga R, Campbell M, Deutschmann B, Gascon D, Gola A, Merzi S, Michalowska-Forsyth A, Penna M, Gómez S, Kratochwil N. Performance evaluation of the FastIC readout ASIC with emphasis on Cherenkov emission in TOF-PET. Phys Med Biol 2024; 69:115014. [PMID: 38657637 DOI: 10.1088/1361-6560/ad42fe] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2023] [Accepted: 04/24/2024] [Indexed: 04/26/2024]
Abstract
Objective.The efficient usage of prompt photons like Cherenkov emission is of great interest for the design of the next generation, cost-effective, and ultra-high-sensitivity time-of-flight positron emission tomography (TOF-PET) scanners. With custom, high power consuming, readout electronics and fast digitization the prospect of sub-300 ps FWHM with PET-sized BGO crystals have been shown. However, these results are not scalable to a full system consisting of thousands of detector elements.Approach.To pave the way toward a full TOF-PET scanner, we examine the performance of the FastIC ASIC with Cherenkov-emitting scintillators (BGO), together with one of the most recent SiPM detector developments based on metal trenching from FBK. The FastIC is a highly configurable ASIC with 8 input channels, a power consumption of 12 mW ch-1and excellent linearity on the energy measurement. To put the timing performance of the FastIC into perspective, comparison measurements with high-power consuming readout electronics are performed.Main results.We achieve a best CTR FWHM of 330 ps for 2 × 2 × 3 mm3and 490 ps for 2 × 2 × 20 mm3BGO crystals with the FastIC. In addition, using 20 mm long LSO:Ce:Ca crystals, CTR values of 129 ps FWHM have been measured with the FastIC, only slightly worse to the state-of-the-art of 95 ps obtained with discrete HF electronics.Significance.For the first time, the timing capability of BGO with a scalable ASIC has been evaluated. The findings underscore the potential of the FastIC ASIC in the development of cost-effective TOF-PET scanners with excellent timing characteristics.
Collapse
Affiliation(s)
- Markus Piller
- CERN, Esplanade des Particules 1, 1211 Meyrin, Switzerland
- Graz University of Technology, Institute of Electronics, A-8010 Graz, Austria
| | | | - Giulia Terragni
- CERN, Esplanade des Particules 1, 1211 Meyrin, Switzerland
- Technical University of Vienna, Austria
| | - Jerome Alozy
- CERN, Esplanade des Particules 1, 1211 Meyrin, Switzerland
| | | | - Rafael Ballabriga
- CERN, Esplanade des Particules 1, 1211 Meyrin, Switzerland
- University of Barcelona, Spain
| | | | - Bernd Deutschmann
- Graz University of Technology, Institute of Electronics, A-8010 Graz, Austria
| | | | - Alberto Gola
- Fondazione Bruno Kessler, Via Sommarive, 18 I-38123, Trento, Italy
| | - Stefano Merzi
- Fondazione Bruno Kessler, Via Sommarive, 18 I-38123, Trento, Italy
| | | | - Michele Penna
- Fondazione Bruno Kessler, Via Sommarive, 18 I-38123, Trento, Italy
| | - Sergio Gómez
- University of Barcelona, Spain
- Serra Hunter Fellow at Polytechnic University of Catalonia, Spain
| | - Nicolaus Kratochwil
- CERN, Esplanade des Particules 1, 1211 Meyrin, Switzerland
- Department of Biomedical Engineering, University of California, Davis, United States of America
| |
Collapse
|
3
|
He W, Zhao Y, Huang W, Zhao X, Niu M, Yang H, Zhang L, Ren Q, Gu Z. A multi-resolution TOF-DOI detector for human brain dedicated PET scanner. Phys Med Biol 2024; 69:025023. [PMID: 38181423 DOI: 10.1088/1361-6560/ad1b6b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Accepted: 01/05/2024] [Indexed: 01/07/2024]
Abstract
Objective. We propose a single-ended readout, multi-resolution detector design that can achieve high spatial, depth-of-interaction (DOI), and time-of-flight (TOF) resolutions, as well as high sensitivity for human brain-dedicated positron emission tomography (PET) scanners.Approach. The detector comprised two layers of LYSO crystal arrays and a lightguide in between. The top (gamma ray entrance) layer consisted of a 16 × 16 array of 1.53 × 1.53 × 6 mm3LYSO crystals for providing high spatial resolution. The bottom layer consisted of an 8 × 8 array of 3.0 × 3.0 × 15 mm3LYSO crystals that were one-to-one coupled to an 8 × 8 multipixel photon counter (MPPC) array for providing high TOF resolution. The 2 mm thick lightguide introduces inter-crystal light sharing that causes variations of the light distribution patterns for high DOI resolution. The detector was read out by a PETsys TOFPET2 application-specific integrated circuit.Main result. The top and bottom layers were distinguished by a convolutional neural network with 97% accuracy. All crystals in the top and bottom layers were resolved. The inter-crystal scatter (ICS) events in the bottom layer were identified, and the measured average DOI resolution of the bottom layer was 4.1 mm. The coincidence time resolution (CTR) for the top-top, top-bottom, and bottom-bottom coincidences was 476 ps, 405 ps, and 298 ps, respectively. When ICS events were excluded from the bottom layer, the CTR of the bottom-bottom coincidence was 277 ps.Significance. The top layer of the proposed two-layer detector achieved a high spatial resolution and the bottom layer achieved a high TOF resolution. Together with its high DOI resolution and detection efficiency, the proposed detector is well suited for next-generation high-performance brain-dedicated PET scanners.
Collapse
Affiliation(s)
- Wen He
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
- Peking University Shenzhen Graduate School, Shenzhen, People's Republic of China
| | - Yangyang Zhao
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
| | - Wenjie Huang
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
| | - Xin Zhao
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
| | - Ming Niu
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
| | - Hang Yang
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
| | - Lei Zhang
- Peking University Shenzhen Graduate School, Shenzhen, People's Republic of China
- Institute of Cancer Research, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
| | - Qiushi Ren
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
- Peking University Shenzhen Graduate School, Shenzhen, People's Republic of China
| | - Zheng Gu
- Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Shenzhen, People's Republic of China
- Peking University Shenzhen Graduate School, Shenzhen, People's Republic of China
| |
Collapse
|
4
|
Lee JS, Lee MS. Advancements in Positron Emission Tomography Detectors: From Silicon Photomultiplier Technology to Artificial Intelligence Applications. PET Clin 2024; 19:1-24. [PMID: 37802675 DOI: 10.1016/j.cpet.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/08/2023]
Abstract
This review article focuses on PET detector technology, which is the most crucial factor in determining PET image quality. The article highlights the desired properties of PET detectors, including high detection efficiency, spatial resolution, energy resolution, and timing resolution. Recent advancements in PET detectors to improve these properties are also discussed, including the use of silicon photomultiplier technology, advancements in depth-of-interaction and time-of-flight PET detectors, and the use of artificial intelligence for detector development. The article provides an overview of PET detector technology and its recent advancements, which can significantly enhance PET image quality.
Collapse
Affiliation(s)
- Jae Sung Lee
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 03080, South Korea; Brightonix Imaging Inc., Seoul 04782, South Korea
| | - Min Sun Lee
- Environmental Radioactivity Assessment Team, Nuclear Emergency & Environmental Protection Division, Korea Atomic Energy Research Institute, Daejeon 34057, South Korea.
| |
Collapse
|
5
|
Nadig V, Hornisch M, Oehm J, Herweg K, Schulz V, Gundacker S. 16-channel SiPM high-frequency readout with time-over-threshold discrimination for ultrafast time-of-flight applications. EJNMMI Phys 2023; 10:76. [PMID: 38044383 PMCID: PMC10694125 DOI: 10.1186/s40658-023-00594-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2023] [Accepted: 11/20/2023] [Indexed: 12/05/2023] Open
Abstract
BACKGROUND Over the past five years, ultrafast high-frequency (HF) readout concepts have advanced the timing performance of silicon photomultipliers (SiPMs). The shown impact in time-of-flight (TOF) techniques can further push the limits in light detection and ranging (LiDAR), time-of-flight positron-emission tomography (TOF-PET), time-of-flight computed tomography (TOF-CT) or high-energy physics (HEP). However, upscaling these electronics to a system-applicable, multi-channel readout, has remained a challenging task, posed by the use of discrete components and a high power consumption. To this day, there are no means to exploit the high TOF resolution of these electronics on system scale or to measure the actual timing performance limits of a full detector block. METHODS In this work, we present a 16-channel HF readout board, including leading-edge discrimination and a linearized time-over-threshold (TOT) method, which is fully compatible with a high-precision time-to-digital converters (TDCs), such as the picoTDC developed at CERN. The discrete implementation allows ideal adaptation of this readout to a broad range of detection tasks. As a first step, the functionality of the circuit has been tested using the TOFPET2 ASIC as back-end electronics to emulate the TDC, also in view of its properties as a highly scalable data acquisition solution. RESULTS The produced board is able to mitigate influences of baseline shifts in the TOFPET2 front end, which has been shown in experiments with a pulsed laser, increasing the achievable intrinsic coincidence timing resolution (CTR) of the TOFPET2 readout electronics from 70 ps (FWHM) to 62 ps (FWHM). Single-channel coincidence experiments including a [Formula: see text]-source, 2[Formula: see text]2[Formula: see text]3 mm[Formula: see text] LYSO:Ce,Ca crystals and Broadcom NUV-MT SiPMs resulted in a CTR of 118 ps (FWHM). For a 4[Formula: see text]4 matrix of 3.88[Formula: see text]3.88[Formula: see text]19 mm[Formula: see text] LYSO:Ce,Ca crystals one-to-one coupled to a 4[Formula: see text]4 array of Broadcom NUV-MT SiPMs, an average CTR of 223 ps (FWHM) was obtained. CONCLUSION The implemented 16-channel HF electronics are fully functionall and have a negligible influence on the timing performance of the back-end electronics used, here the TOFPET2 ASIC. The ongoing integration of the picoTDC with the 16-channel HF board is expected to further set the path toward sub-100 ps TOF-PET and sub-30ps TOF resolution for single-photon detection.
Collapse
Affiliation(s)
- Vanessa Nadig
- Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - Matthias Hornisch
- Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - Jakob Oehm
- Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - Katrin Herweg
- Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - Volkmar Schulz
- Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Pauwelsstraße 19, 52074, Aachen, Germany
- III. Physikalisches Institut B, RWTH Aachen University, Otto-Blumenthal-Straße, 52074, Aachen, Germany
- Fraunhofer Institute for Digital Medicine MEVIS, Forckenbeckstraße 55, 52074, Aachen, Germany
| | - Stefan Gundacker
- Department of Physics of Molecular Imaging Systems, Experimental Molecular Imaging, RWTH Aachen University, Forckenbeckstraße 55, 52074, Aachen, Germany.
| |
Collapse
|
6
|
Weindel K, Nadig V, Herweg K, Schulz V, Gundacker S. A time-based double-sided readout concept of 100 mm LYSO:Ce,Ca fibres for future axial TOF-PET. EJNMMI Phys 2023; 10:43. [PMID: 37450099 PMCID: PMC10349027 DOI: 10.1186/s40658-023-00563-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 07/05/2023] [Indexed: 07/18/2023] Open
Abstract
BACKGROUND Positron emission tomography (PET) requires a high signal-to-noise ratio (SNR) to improve image quality, with time-of-flight (TOF) being an effective way to boost the SNR. However, the scanner sensitivity and resolution must be maintained. The use of axially aligned 100-mm LYSO:Ce,Ca scintillation crystals with double-sided readout has the potential of ground-breaking TOF and sensitivity, while reducing parallax errors through depth-of-interaction (DOI) estimation, and also allowing a reduction in the number of readout channels required, resulting in cost benefits. Due to orientation, these fibres may also facilitate the integration of TOF-PET with magnetic resonance imaging (MRI) in hybrid imaging systems. The challenge of achieving a good spatial resolution with such long axial fibres is directly related to the achievable TOF resolution. In this study, the timing performance and DOI resolution of emerging high-performance materials were investigated to assess the merits of this approach in organ-dedicated or total-body/large-scale PET imaging systems. METHODS LYSO:Ce,Ca scintillation fibres of 20 mm and 100 mm length were tested in various operating and readout configurations to determine the best achievable coincidence time resolution (CTR) and DOI resolution. The tests were performed using state-of-the-art high-frequency (HF) readout and commercially available silicon photomultipliers (SiPMs) from Broadcom Inc. RESULTS For the 100-mm fibre, an average CTR performance of [Formula: see text] ps FWHM and an average depth-of-interaction resolution within the fibre of [Formula: see text] mm FWHM could be obtained. The 20-mm fibre showed a sub-100 ps CTR of [Formula: see text] ps FWHM and a fibre resolution of [Formula: see text] mm FWHM in the double-sided readout configuration. CONCLUSION With modern SiPMs and crystals, a double-sided readout of long fibres can achieve excellent timing resolution and field-advancing TOF resolution, outperforming commercial PET systems. With 100-mm fibres, an electronic channel reduction of about a factor 2.5 is inherent, with larger reduction factors conceivable, which can lead to lower production costs. The spatial resolution was shown to be limited in the axial direction with 12 mm, but is defined to 3 mm in all other directions. Recent SiPM and scintillator developments are expected to improve on the time and spatial resolution to be investigated in future prototypes.
Collapse
Affiliation(s)
- Konstantin Weindel
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Vanessa Nadig
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Katrin Herweg
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Volkmar Schulz
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
- Physics Institute III B, RWTH Aachen University, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
| | - Stefan Gundacker
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.
| |
Collapse
|