1
|
Karchoud JF, Hoeboer CM, Piwanski G, Haagsma JA, Olff M, van de Schoot R, van Zuiden M. Towards accurate screening and prevention for PTSD (2-ASAP): protocol of a longitudinal prospective cohort study. BMC Psychiatry 2024; 24:688. [PMID: 39407131 PMCID: PMC11476939 DOI: 10.1186/s12888-024-06110-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 09/23/2024] [Indexed: 10/20/2024] Open
Abstract
BACKGROUND Effective preventive interventions for PTSD rely on early identification of individuals at risk for developing PTSD. To establish early post-trauma who are at risk, there is a need for accurate prognostic risk screening instruments for PTSD that can be widely implemented in recently trauma-exposed adults. Achieving such accuracy and generalizability requires external validation of machine learning classification models. The current 2-ASAP cohort study will perform external validation on both full and minimal feature sets of supervised machine learning classification models assessing individual risk to follow an adverse PTSD symptom trajectory over the course of 1 year. We will derive these models from the TraumaTIPS cohort, separately for men and women. METHOD The 2-ASAP longitudinal cohort will include N = 863 adults (N = 436 females, N = 427 males) who were recently exposed to acute civilian trauma. We will include civilian victims of accidents, crime and calamities at Victim Support Netherlands; and who were presented for medical evaluation of (suspected) traumatic injuries by emergency transportation to the emergency department. The baseline assessment within 2 months post-trauma will include self-report questionnaires on demographic, medical and traumatic event characteristics; potential risk and protective factors for PTSD; PTSD symptom severity and other adverse outcomes; and current best-practice PTSD screening instruments. Participants will be followed at 3, 6, 9, and 12 months post-trauma, assessing PTSD symptom severity and other adverse outcomes via self-report questionnaires. DISCUSSION The ultimate goal of our study is to improve accurate screening and prevention for PTSD in recently trauma-exposed civilians. To enable future large-scale implementation, we will use self-report data to inform the prognostic models; and we will derive a minimal feature set of the classification models. This can be transformed into a short online screening instrument that is user-friendly for recently trauma-exposed adults to fill in. The eventual short online screening instrument will classify early post-trauma which adults are at risk for developing PTSD. Those at risk can be targeted and may subsequently benefit from preventive interventions, aiming to reduce PTSD and relatedly improve psychological, functional and economic outcomes.
Collapse
Affiliation(s)
- Jeanet F Karchoud
- Amsterdam UMC, University of Amsterdam, Psychiatry, Amsterdam Public Health, Amsterdam, The Netherlands
| | - Chris M Hoeboer
- Amsterdam UMC, University of Amsterdam, Psychiatry, Amsterdam Public Health, Amsterdam, The Netherlands
| | - Greta Piwanski
- Amsterdam UMC, University of Amsterdam, Psychiatry, Amsterdam Public Health, Amsterdam, The Netherlands
| | | | - Miranda Olff
- Amsterdam UMC, University of Amsterdam, Psychiatry, Amsterdam Public Health, Amsterdam, The Netherlands
- ARQ National Psychotrauma Centre, Diemen, The Netherlands
| | - Rens van de Schoot
- Department of Methods and Statistics, Utrecht University, Utrecht, The Netherlands
| | - Mirjam van Zuiden
- Amsterdam UMC, University of Amsterdam, Psychiatry, Amsterdam Public Health, Amsterdam, The Netherlands.
- Department of Clinical Psychology, Utrecht University, Utrecht, The Netherlands.
| |
Collapse
|
2
|
Chen G, Zou L, Ji Z. A review: Blood pressure monitoring based on PPG and circadian rhythm. APL Bioeng 2024; 8:031501. [PMID: 39049850 PMCID: PMC11268918 DOI: 10.1063/5.0206980] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Accepted: 06/26/2024] [Indexed: 07/27/2024] Open
Abstract
The demand for ambulatory blood pressure monitoring (ABPM) is increasing due to the global rise in cardiovascular disease patients. However, conventional ABPM methods are discontinuous and can disrupt daily activities and sleep patterns. Photoplethysmography (PPG) is gaining attention from researchers due to its simplicity, portability, affordability, and ease of signal acquisition. This paper critically examines the advancements achieved in the technology of PPG-guided noninvasive blood pressure (BP) monitoring and explores future opportunities. We have performed a literature search using the Web of Science and PubMed search engines, from January 2018 to October 2023, for PPG signal quality assessment (SQA), cuffless BP estimation using single PPG, and associations between circadian rhythm and BP. Based on this foundation, we first examine the impact of PPG signal quality on blood pressure estimation results while focusing on methods for assessing PPG signal quality. Subsequently, the methods documented for estimating cuff-free BP from PPG signals are summarized. Furthermore, the study examines how individual differences affect the accuracy of BP estimation, incorporating the factors that influence arterial blood pressure (ABP) and elucidating the impact of circadian rhythm on blood pressure. Finally, there will be a summary of the study's findings and suggestions for future research directions.
Collapse
Affiliation(s)
- Gang Chen
- College of Bioengineering, Chongqing University, Chongqing 400030, China
| | - Linglin Zou
- Department of oncology, Affiliated Hospital of Southwest Medical University, Luzhou 646000, China
| | - Zhong Ji
- Author to whom correspondence should be addressed:
| |
Collapse
|
3
|
Fonseca P, Ross M, Cerny A, Anderer P, Schipper F, Grassi A, van Gilst M, Overeem S. Estimating the Severity of Obstructive Sleep Apnea Using ECG, Respiratory Effort and Neural Networks. IEEE J Biomed Health Inform 2024; 28:3895-3906. [PMID: 38551823 DOI: 10.1109/jbhi.2024.3383240] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/03/2024]
Abstract
OBJECTIVE wearable sensor technology has progressed significantly in the last decade, but its clinical usability for the assessment of obstructive sleep apnea (OSA) is limited by the lack of large and representative datasets simultaneously acquired with polysomnography (PSG). The objective of this study was to explore the use of cardiorespiratory signals common in standard PSGs which can be easily measured with wearable sensors, to estimate the severity of OSA. METHODS an artificial neural network was developed for detecting sleep disordered breathing events using electrocardiogram (ECG) and respiratory effort. The network was combined with a previously developed cardiorespiratory sleep staging algorithm and evaluated in terms of sleep staging classification performance, apnea-hypopnea index (AHI) estimation, and OSA severity estimation against PSG on a cohort of 653 participants with a wide range of OSA severity. RESULTS four-class sleep staging achieved a κ of 0.69 versus PSG, distinguishing wake, combined N1-N2, N3 and REM. AHI estimation achieved an intraclass correlation coefficient of 0.91, and high diagnostic performance for different OSA severity thresholds. CONCLUSIONS this study highlights the potential of using cardiorespiratory signals to estimate OSA severity, even without the need for airflow or oxygen saturation (SpO2), traditionally used for assessing OSA. SIGNIFICANCE while further research is required to translate these findings to practical and unobtrusive sensors, this study demonstrates how existing, large datasets can serve as a foundation for wearable systems for OSA monitoring. Ultimately, this approach could enable long-term assessment of sleep disordered breathing, facilitating new avenues for clinical research in this field.
Collapse
|
4
|
Xie J, Fonseca P, van Dijk J, Overeem S, Long X. A multi-task learning model using RR intervals and respiratory effort to assess sleep disordered breathing. Biomed Eng Online 2024; 23:45. [PMID: 38705982 PMCID: PMC11070105 DOI: 10.1186/s12938-024-01240-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Accepted: 04/23/2024] [Indexed: 05/07/2024] Open
Abstract
BACKGROUND Sleep-disordered breathing (SDB) affects a significant portion of the population. As such, there is a need for accessible and affordable assessment methods for diagnosis but also case-finding and long-term follow-up. Research has focused on exploiting cardiac and respiratory signals to extract proxy measures for sleep combined with SDB event detection. We introduce a novel multi-task model combining cardiac activity and respiratory effort to perform sleep-wake classification and SDB event detection in order to automatically estimate the apnea-hypopnea index (AHI) as severity indicator. METHODS The proposed multi-task model utilized both convolutional and recurrent neural networks and was formed by a shared part for common feature extraction, a task-specific part for sleep-wake classification, and a task-specific part for SDB event detection. The model was trained with RR intervals derived from electrocardiogram and respiratory effort signals. To assess performance, overnight polysomnography (PSG) recordings from 198 patients with varying degree of SDB were included, with manually annotated sleep stages and SDB events. RESULTS We achieved a Cohen's kappa of 0.70 in the sleep-wake classification task, corresponding to a Spearman's correlation coefficient (R) of 0.830 between the estimated total sleep time (TST) and the TST obtained from PSG-based sleep scoring. Combining the sleep-wake classification and SDB detection results of the multi-task model, we obtained an R of 0.891 between the estimated and the reference AHI. For severity classification of SBD groups based on AHI, a Cohen's kappa of 0.58 was achieved. The multi-task model performed better than a single-task model proposed in a previous study for AHI estimation, in particular for patients with a lower sleep efficiency (R of 0.861 with the multi-task model and R of 0.746 with single-task model with subjects having sleep efficiency < 60%). CONCLUSION Assisted with automatic sleep-wake classification, our multi-task model demonstrated proficiency in estimating AHI and assessing SDB severity based on AHI in a fully automatic manner using RR intervals and respiratory effort. This shows the potential for improving SDB screening with unobtrusive sensors also for subjects with low sleep efficiency without adding additional sensors for sleep-wake detection.
Collapse
Affiliation(s)
- Jiali Xie
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.
- Department of Electrical Engineering, Eindhoven University of Technology, PO Box 513, 5600 MB, Eindhoven, The Netherlands.
- Eindhoven MedTech Innovaton Center (e/MTIC), P.O. Box 513, 5600 MB, Eindhoven, The Netherlands.
| | - Pedro Fonseca
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Philips Research, High Tech Campus, 5656 AE, Eindhoven, The Netherlands
- Eindhoven MedTech Innovaton Center (e/MTIC), P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
| | - Johannes van Dijk
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE, Heeze, The Netherlands
- Department of Orthodontics, Ulm University, 89081, Ulm, Germany
- Eindhoven MedTech Innovaton Center (e/MTIC), P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
| | - Sebastiaan Overeem
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE, Heeze, The Netherlands
- Eindhoven MedTech Innovaton Center (e/MTIC), P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
| | - Xi Long
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Eindhoven MedTech Innovaton Center (e/MTIC), P.O. Box 513, 5600 MB, Eindhoven, The Netherlands
| |
Collapse
|
5
|
Xie J, Fonseca P, van Dijk JP, Long X, Overeem S. The Use of Respiratory Effort Improves an ECG-Based Deep Learning Algorithm to Assess Sleep-Disordered Breathing. Diagnostics (Basel) 2023; 13:2146. [PMID: 37443540 DOI: 10.3390/diagnostics13132146] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2023] [Revised: 06/14/2023] [Accepted: 06/19/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND Sleep apnea is a prevalent sleep-disordered breathing (SDB) condition that affects a large population worldwide. Research has demonstrated the potential of using electrocardiographic (ECG) signals (heart rate and ECG-derived respiration, EDR) to detect SDB. However, EDR may be a suboptimal replacement for respiration signals. METHODS We evaluated a previously described ECG-based deep learning algorithm in an independent dataset including 198 patients and compared performance for SDB event detection using thoracic respiratory effort versus EDR. We also evaluated the algorithm in terms of apnea-hypopnea index (AHI) estimation performance, and SDB severity classification based on the estimated AHI. RESULTS Using respiratory effort instead of EDR, we achieved an improved performance in SDB event detection (F1 score = 0.708), AHI estimation (Spearman's correlation = 0.922), and SDB severity classification (Cohen's kappa of 0.62 was obtained based on AHI). CONCLUSION Respiratory effort is superior to EDR to assess SDB. Using respiratory effort and ECG, the previously described algorithm achieves good performance in a new dataset from an independent laboratory confirming its adequacy for this task.
Collapse
Affiliation(s)
- Jiali Xie
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
| | - Pedro Fonseca
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Philips Research, High Tech Campus, 5656 AE Eindhoven, The Netherlands
| | - Johannes P van Dijk
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE Heeze, The Netherlands
- Department of Orthodontics, Ulm University, 89081 Ulm, Germany
| | - Xi Long
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Philips Research, High Tech Campus, 5656 AE Eindhoven, The Netherlands
| | - Sebastiaan Overeem
- Biomedical Diagnostics Lab, Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ Eindhoven, The Netherlands
- Sleep Medicine Center Kempenhaeghe, 5591 VE Heeze, The Netherlands
| |
Collapse
|
6
|
Lombardi S, Francia P, Deodati R, Calamai I, Luchini M, Spina R, Bocchi L. COVID-19 Detection Using Photoplethysmography and Neural Networks. SENSORS (BASEL, SWITZERLAND) 2023; 23:2561. [PMID: 36904763 PMCID: PMC10007577 DOI: 10.3390/s23052561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/23/2023] [Accepted: 02/23/2023] [Indexed: 06/18/2023]
Abstract
The early identification of microvascular changes in patients with Coronavirus Disease 2019 (COVID-19) may offer an important clinical opportunity. This study aimed to define a method, based on deep learning approaches, for the identification of COVID-19 patients from the analysis of the raw PPG signal, acquired with a pulse oximeter. To develop the method, we acquired the PPG signal of 93 COVID-19 patients and 90 healthy control subjects using a finger pulse oximeter. To select the good quality portions of the signal, we developed a template-matching method that excludes samples corrupted by noise or motion artefacts. These samples were subsequently used to develop a custom convolutional neural network model. The model accepts PPG signal segments as input and performs a binary classification between COVID-19 and control samples. The proposed model showed good performance in identifying COVID-19 patients, achieving 83.86% accuracy and 84.30% sensitivity (hold-out validation) on test data. The obtained results indicate that photoplethysmography may be a useful tool for microcirculation assessment and early recognition of SARS-CoV-2-induced microvascular changes. In addition, such a noninvasive and low-cost method is well suited for the development of a user-friendly system, potentially applicable even in resource-limited healthcare settings.
Collapse
Affiliation(s)
- Sara Lombardi
- Department of Information Engineering, University of Florence, 50139 Florence, Italy
| | - Piergiorgio Francia
- Department of Information Engineering, University of Florence, 50139 Florence, Italy
| | | | | | | | | | - Leonardo Bocchi
- Department of Information Engineering, University of Florence, 50139 Florence, Italy
| |
Collapse
|
7
|
Charlton PH, Kyriacou PA, Mant J, Marozas V, Chowienczyk P, Alastruey J. Wearable Photoplethysmography for Cardiovascular Monitoring. PROCEEDINGS OF THE IEEE. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 2022; 110:355-381. [PMID: 35356509 PMCID: PMC7612541 DOI: 10.1109/jproc.2022.3149785] [Citation(s) in RCA: 48] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2021] [Revised: 01/06/2022] [Accepted: 01/27/2022] [Indexed: 05/29/2023]
Abstract
Smart wearables provide an opportunity to monitor health in daily life and are emerging as potential tools for detecting cardiovascular disease (CVD). Wearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram signal, an optical measure of the arterial pulse wave that is strongly influenced by the heart and blood vessels. In this survey, we summarize the fundamentals of wearable photoplethysmography and its analysis, identify its potential clinical applications, and outline pressing directions for future research in order to realize its full potential for tackling CVD.
Collapse
Affiliation(s)
- Peter H. Charlton
- Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging SciencesKing’s College London, King’s Health PartnersLondonSE1 7EUU.K.
- Research Centre for Biomedical Engineering, CityUniversity of LondonLondonEC1V 0HBU.K.
- Department of Public Health and Primary CareUniversity of CambridgeCambridgeCB1 8RNU.K.
| | - Panicos A. Kyriacou
- Research Centre for Biomedical Engineering, CityUniversity of LondonLondonEC1V 0HBU.K.
| | - Jonathan Mant
- Department of Public Health and Primary CareUniversity of CambridgeCambridgeCB1 8RNU.K.
| | - Vaidotas Marozas
- Department of Electronics Engineering and the Biomedical Engineering Institute, Kaunas University of Technology44249KaunasLithuania
| | - Phil Chowienczyk
- Department of Clinical PharmacologyKing’s College LondonLondonSE1 7EHU.K.
| | - Jordi Alastruey
- Department of Biomedical EngineeringSchool of Biomedical Engineering and Imaging SciencesKing’s College London, King’s Health PartnersLondonSE1 7EUU.K.
| |
Collapse
|
8
|
Park J, Seok HS, Kim SS, Shin H. Photoplethysmogram Analysis and Applications: An Integrative Review. Front Physiol 2022; 12:808451. [PMID: 35300400 PMCID: PMC8920970 DOI: 10.3389/fphys.2021.808451] [Citation(s) in RCA: 77] [Impact Index Per Article: 25.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2021] [Accepted: 12/21/2021] [Indexed: 12/03/2022] Open
Abstract
Beyond its use in a clinical environment, photoplethysmogram (PPG) is increasingly used for measuring the physiological state of an individual in daily life. This review aims to examine existing research on photoplethysmogram concerning its generation mechanisms, measurement principles, clinical applications, noise definition, pre-processing techniques, feature detection techniques, and post-processing techniques for photoplethysmogram processing, especially from an engineering point of view. We performed an extensive search with the PubMed, Google Scholar, Institute of Electrical and Electronics Engineers (IEEE), ScienceDirect, and Web of Science databases. Exclusion conditions did not include the year of publication, but articles not published in English were excluded. Based on 118 articles, we identified four main topics of enabling PPG: (A) PPG waveform, (B) PPG features and clinical applications including basic features based on the original PPG waveform, combined features of PPG, and derivative features of PPG, (C) PPG noise including motion artifact baseline wandering and hypoperfusion, and (D) PPG signal processing including PPG preprocessing, PPG peak detection, and signal quality index. The application field of photoplethysmogram has been extending from the clinical to the mobile environment. Although there is no standardized pre-processing pipeline for PPG signal processing, as PPG data are acquired and accumulated in various ways, the recently proposed machine learning-based method is expected to offer a promising solution.
Collapse
Affiliation(s)
- Junyung Park
- Department of Biomedical Engineering, Chonnam National University, Yeosu, South Korea
| | - Hyeon Seok Seok
- Department of Biomedical Engineering, Chonnam National University, Yeosu, South Korea
| | - Sang-Su Kim
- Department of Biomedical Engineering, Chonnam National University, Yeosu, South Korea
| | - Hangsik Shin
- Department of Convergence Medicine, University of Ulsan College of Medicine, Asan Medical Center, Seoul, South Korea
| |
Collapse
|
9
|
Betz K, van der Velden R, Gawalko M, Hermans A, Pluymaekers N, Hillmann HAK, Hendriks J, Duncker D, Linz D. [Interpretation of photoplethysmography: a step-by-step guide]. Herzschrittmacherther Elektrophysiol 2021; 32:406-411. [PMID: 34304276 PMCID: PMC8310409 DOI: 10.1007/s00399-021-00795-y] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Accepted: 06/30/2021] [Indexed: 11/05/2022]
Abstract
By applying photoplethysmography (PPG), the camera of the mobile phone can be used to remotely assess heart rate and rhythm, which was widely used in conjunction with teleconsultations within the TeleCheck-AF project during the coronavirus disease 2019 (COVID-19) pandemic. Herein, we provide an educational, structured, stepwise practical guide on how to interpret PPG signals. A better understanding of PPG recordings is critical for the implementation of this widely available technology into clinical practice.
Collapse
Affiliation(s)
- Konstanze Betz
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht UMC+, 6202 AZ, Maastricht, Niederlande
| | - Rachel van der Velden
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht UMC+, 6202 AZ, Maastricht, Niederlande
| | - Monika Gawalko
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht UMC+, 6202 AZ, Maastricht, Niederlande
| | - Astrid Hermans
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht UMC+, 6202 AZ, Maastricht, Niederlande
| | - Nikki Pluymaekers
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht UMC+, 6202 AZ, Maastricht, Niederlande
| | - Henrike A K Hillmann
- Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Hannover, Deutschland
| | - Jeroen Hendriks
- Caring Futures Institute, College of Nursing and Health Sciences, Flinders University, Adelaide, Australien
- Department of Cardiology, Radboud University Medical Centre, Nijmegen, Niederlande
| | - David Duncker
- Hannover Heart Rhythm Center, Department of Cardiology and Angiology, Hannover Medical School, Hannover, Deutschland
| | - Dominik Linz
- Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht UMC+, 6202 AZ, Maastricht, Niederlande.
- Department of Cardiology, Radboud University Medical Centre, Nijmegen, Niederlande.
- Centre for Heart Rhythm Disorders, University of Adelaide and Royal Adelaide Hospital, Adelaide, Australien.
- Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Kopenhagen, Dänemark.
| |
Collapse
|
10
|
Recurrence Plot and Machine Learning for Signal Quality Assessment of Photoplethysmogram in Mobile Environment. SENSORS 2021; 21:s21062188. [PMID: 33804794 PMCID: PMC8004064 DOI: 10.3390/s21062188] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Revised: 03/17/2021] [Accepted: 03/18/2021] [Indexed: 11/17/2022]
Abstract
The purpose of this study was to develop a machine learning model that could accurately evaluate the quality of a photoplethysmogram based on the shape of the photoplethysmogram and the phase relevance in a pulsatile waveform without requiring complicated pre-processing. Photoplethysmograms were recorded for 76 participants (5 min for each participant). All recorded photoplethysmograms were segmented for each beat to obtain a total of 49,561 pulsatile segments. These pulsatile segments were manually labeled as ‘good’ and ‘poor’ classes and converted to a two-dimensional phase space trajectory image using a recurrence plot. The classification model was implemented using a convolutional neural network with a two-layer structure. As a result, the proposed model correctly classified 48,827 segments out of 49,561 segments and misclassified 734 segments, showing a balanced accuracy of 0.975. Sensitivity, specificity, and positive predictive values of the developed model for the test dataset with a ‘poor’ class classification were 0.964, 0.987, and 0.848, respectively. The area under the curve was 0.994. The convolutional neural network model with recurrence plot as input proposed in this study can be used for signal quality assessment as a generalized model with high accuracy through data expansion. It has an advantage in that it does not require complicated pre-processing or a feature detection process.
Collapse
|
11
|
Shin H, Park J, Seok HS, Kim SS. Photoplethysmogram analysis and applications: An Integrative Review (Preprint). JMIR BIOMEDICAL ENGINEERING 2020. [DOI: 10.2196/25567] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
|
12
|
Han D, Bashar SK, Mohagheghian F, Ding E, Whitcomb C, McManus DD, Chon KH. Premature Atrial and Ventricular Contraction Detection using Photoplethysmographic Data from a Smartwatch. SENSORS (BASEL, SWITZERLAND) 2020; 20:E5683. [PMID: 33028000 PMCID: PMC7582300 DOI: 10.3390/s20195683] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 09/19/2020] [Accepted: 09/30/2020] [Indexed: 12/12/2022]
Abstract
We developed an algorithm to detect premature atrial contraction (PAC) and premature ventricular contraction (PVC) using photoplethysmographic (PPG) data acquired from a smartwatch. Our PAC/PVC detection algorithm is composed of a sequence of algorithms that are combined to discriminate various arrhythmias. A novel vector resemblance method is used to enhance the PAC/PVC detection results of the Poincaré plot method. The new PAC/PVC detection algorithm with our automated motion and noise artifact detection approach yielded a sensitivity of 86% for atrial fibrillation (AF) subjects while the overall sensitivity was 67% when normal sinus rhythm (NSR) subjects were also included. The specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy values for the combined data consisting of both NSR and AF subjects were 97%, 81%, 94% and 92%, respectively, for PAC/PVC detection combined with our automated motion and noise artifact detection approach. Moreover, when AF detection was compared with and without PAC/PVC, the sensitivity and specificity increased from 94.55% to 98.18% and from 95.75% to 97.90%, respectively. For additional independent testing data, we used two datasets: a smartwatch PPG dataset that was collected in our ongoing clinical study, and a pulse oximetry PPG dataset from the Medical Information Mart for Intensive Care III database. The PAC/PVC classification results of the independent testing on these two other datasets are all above 92% for sensitivity, specificity, PPV, NPV, and accuracy. The proposed combined approach to detect PAC and PVC can ultimately lead to better accuracy in AF detection. This is one of the first studies involving detection of PAC and PVC using PPG recordings from a smartwatch. The proposed method can potentially be of clinical importance as this enhanced capability can lead to fewer false positive detections of AF, especially for those NSR subjects with frequent episodes of PAC/PVC.
Collapse
Affiliation(s)
- Dong Han
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (D.H.); (S.K.B.); (F.M.)
| | - Syed Khairul Bashar
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (D.H.); (S.K.B.); (F.M.)
| | - Fahimeh Mohagheghian
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (D.H.); (S.K.B.); (F.M.)
| | - Eric Ding
- Division of Cardiology, University of Massachusetts Medical School, Worcester, MA 01655, USA; (E.D.); (C.W.); (D.D.M.)
| | - Cody Whitcomb
- Division of Cardiology, University of Massachusetts Medical School, Worcester, MA 01655, USA; (E.D.); (C.W.); (D.D.M.)
| | - David D. McManus
- Division of Cardiology, University of Massachusetts Medical School, Worcester, MA 01655, USA; (E.D.); (C.W.); (D.D.M.)
| | - Ki H. Chon
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT 06269, USA; (D.H.); (S.K.B.); (F.M.)
| |
Collapse
|
13
|
Papini GB, Fonseca P, van Gilst MM, Bergmans JWM, Vullings R, Overeem S. Wearable monitoring of sleep-disordered breathing: estimation of the apnea-hypopnea index using wrist-worn reflective photoplethysmography. Sci Rep 2020; 10:13512. [PMID: 32782313 PMCID: PMC7421543 DOI: 10.1038/s41598-020-69935-7] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 07/14/2020] [Indexed: 12/15/2022] Open
Abstract
A large part of the worldwide population suffers from obstructive sleep apnea (OSA), a disorder impairing the restorative function of sleep and constituting a risk factor for several cardiovascular pathologies. The standard diagnostic metric to define OSA is the apnea-hypopnea index (AHI), typically obtained by manually annotating polysomnographic recordings. However, this clinical procedure cannot be employed for screening and for long-term monitoring of OSA due to its obtrusiveness and cost. Here, we propose an automatic unobtrusive AHI estimation method fully based on wrist-worn reflective photoplethysmography (rPPG), employing a deep learning model exploiting cardiorespiratory and sleep information extracted from the rPPG signal trained with 250 recordings. We tested our method with an independent set of 188 heterogeneously disordered clinical recordings and we found it estimates the AHI with a good agreement to the gold standard polysomnography reference (correlation = 0.61, estimation error = 3±10 events/h). The estimated AHI was shown to reliably assess OSA severity (weighted Cohen's kappa = 0.51) and screen for OSA (ROC-AUC = 0.84/0.86/0.85 for mild/moderate/severe OSA). These findings suggest that wrist-worn rPPG measurements that can be implemented in wearables such as smartwatches, have the potential to complement standard OSA diagnostic techniques by allowing unobtrusive sleep and respiratory monitoring.
Collapse
Affiliation(s)
- Gabriele B Papini
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands.
- Philips Research, High Tech Campus, 5656 AE, Eindhoven, The Netherlands.
- Sleep Medicine Centre Kempenhaeghe, 5591 VE, Heeze, The Netherlands.
| | - Pedro Fonseca
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Philips Research, High Tech Campus, 5656 AE, Eindhoven, The Netherlands
| | - Merel M van Gilst
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Sleep Medicine Centre Kempenhaeghe, 5591 VE, Heeze, The Netherlands
| | - Jan W M Bergmans
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Philips Research, High Tech Campus, 5656 AE, Eindhoven, The Netherlands
| | - Rik Vullings
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
| | - Sebastiaan Overeem
- Department of Electrical Engineering, Eindhoven University of Technology, 5612 AZ, Eindhoven, The Netherlands
- Sleep Medicine Centre Kempenhaeghe, 5591 VE, Heeze, The Netherlands
| |
Collapse
|
14
|
Papini GB, Fonseca P, Gilst MMV, Bergmans JW, Vullings R, Overeem S. Respiratory activity extracted from wrist-worn reflective photoplethysmography in a sleep-disordered population. Physiol Meas 2020; 41:065010. [PMID: 32428875 DOI: 10.1088/1361-6579/ab9481] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Respiratory activity is an essential parameter to monitor healthy and disordered sleep, and unobtrusive measurement methods have important clinical applications in diagnostics of sleep-related breathing disorders. We propose a respiratory activity surrogate extracted from wrist-worn reflective photoplethysmography validated on a heterogeneous dataset of 389 sleep recordings. APPROACH The surrogate was extracted by interpolating the amplitude of the PPG pulses after evaluation of pulse morphological quality. Subsequent multistep post-processing was applied to remove parts of the surrogate with low quality and high motion levels. In addition to standard respiration rate performance, we evaluated the similarity between surrogate respiratory activity and reference inductance plethysmography of the thorax, using Spearman's correlations and spectral coherence, and assessed the influence of PPG signal quality, motion levels, sleep stages and obstructive sleep apnea. MAIN RESULTS Prior to post-processing, the surrogate already had a strong similarity with the reference (correlation = 0.54, coherence = 0.81), and reached respiration rate estimation performance in line with the literature (estimation error = 0.76± 2.11 breaths/min). Detrimental effects of low PPG quality, high motion levels and sleep-dependent physiological phenomena were significantly mitigated by the proposed post-processing steps (correlation = 0.62, coherence = 0.88, estimation error = 0.53± 1.85 breaths/min). SIGNIFICANCE Wrist-worn PPG can be used to extract respiratory activity, thus allowing respiration monitoring in real-world sleep medicine applications using (consumer) wearable devices.
Collapse
Affiliation(s)
- Gabriele B Papini
- Department of Electrical Engineering, Eindhoven University of Technology, Den Dolech 2, 5612 AZ Eindhoven, The Netherlands. Philips Research, High Tech Campus, 5656 AE Eindhoven, The Netherlands. Sleep Medicine Center Kempenhaeghe, P.O. Box 61, 5590 AB Heeze, The Netherlands
| | | | | | | | | | | |
Collapse
|
15
|
van Gilst MM, van Dijk JP, Krijn R, Hoondert B, Fonseca P, van Sloun RJG, Arsenali B, Vandenbussche N, Pillen S, Maass H, van den Heuvel L, Haakma R, Leufkens TR, Lauwerijssen C, Bergmans JWM, Pevernagie D, Overeem S. Protocol of the SOMNIA project: an observational study to create a neurophysiological database for advanced clinical sleep monitoring. BMJ Open 2019; 9:e030996. [PMID: 31772091 PMCID: PMC6886950 DOI: 10.1136/bmjopen-2019-030996] [Citation(s) in RCA: 36] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
INTRODUCTION Polysomnography (PSG) is the primary tool for sleep monitoring and the diagnosis of sleep disorders. Recent advances in signal analysis make it possible to reveal more information from this rich data source. Furthermore, many innovative sleep monitoring techniques are being developed that are less obtrusive, easier to use over long time periods and in the home situation. Here, we describe the methods of the Sleep and Obstructive Sleep Apnoea Monitoring with Non-Invasive Applications (SOMNIA) project, yielding a database combining clinical PSG with advanced unobtrusive sleep monitoring modalities in a large cohort of patients with various sleep disorders. The SOMNIA database will facilitate the validation and assessment of the diagnostic value of the new techniques, as well as the development of additional indices and biomarkers derived from new and/or traditional sleep monitoring methods. METHODS AND ANALYSIS We aim to include at least 2100 subjects (both adults and children) with a variety of sleep disorders who undergo a PSG as part of standard clinical care in a dedicated sleep centre. Full-video PSG will be performed according to the standards of the American Academy of Sleep Medicine. Each recording will be supplemented with one or more new monitoring systems, including wrist-worn photoplethysmography and actigraphy, pressure sensing mattresses, multimicrophone recording of respiratory sounds including snoring, suprasternal pressure monitoring and multielectrode electromyography of the diaphragm. ETHICS AND DISSEMINATION The study was reviewed by the medical ethical committee of the Maxima Medical Center (Eindhoven, the Netherlands, File no: N16.074). All subjects provide informed consent before participation.The SOMNIA database is built to facilitate future research in sleep medicine. Data from the completed SOMNIA database will be made available for collaboration with researchers outside the institute.
Collapse
Affiliation(s)
- Merel M van Gilst
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
| | - Johannes P van Dijk
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
| | - Roy Krijn
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
| | - Bertram Hoondert
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
| | - Pedro Fonseca
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Philips Research, Eindhoven, North Brabant, The Netherlands
| | - Ruud J G van Sloun
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
| | - Bruno Arsenali
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
| | - Nele Vandenbussche
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
| | - Sigrid Pillen
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
- Industrial Design, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
| | - Henning Maass
- Philips Research, Eindhoven, North Brabant, The Netherlands
| | | | - Reinder Haakma
- Philips Research, Eindhoven, North Brabant, The Netherlands
| | - Tim R Leufkens
- Philips Research, Eindhoven, North Brabant, The Netherlands
- Industrial Design, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
| | | | - Jan W M Bergmans
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Philips Research, Eindhoven, North Brabant, The Netherlands
| | - Dirk Pevernagie
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
| | - Sebastiaan Overeem
- Electrical Engineering, Technische Universiteit Eindhoven, Eindhoven, The Netherlands
- Center for Sleep Medicine, Kempenhaeghe Foundation, Heeze, Noord Brabant, The Netherlands
| |
Collapse
|
16
|
Eerikainen LM, Bonomi AG, Schipper F, Dekker LRC, de Morree HM, Vullings R, Aarts RM. Detecting Atrial Fibrillation and Atrial Flutter in Daily Life Using Photoplethysmography Data. IEEE J Biomed Health Inform 2019; 24:1610-1618. [PMID: 31689222 DOI: 10.1109/jbhi.2019.2950574] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Photoplethysmography (PPG) enables unobtrusive heart rate monitoring, which can be used in wrist-worn applications. Its potential for detecting atrial fibrillation (AF) has been recently presented. Besides AF, another cardiac arrhythmia increasing stroke risk and requiring treatment is atrial flutter (AFL). Currently, the knowledge about AFL detection with PPG is limited. The objective of our study was to develop a model that classifies AF, AFL, and sinus rhythm with or without premature beats from PPG and acceleration data measured at the wrist in daily life. METHODS A dataset of 40 patients was collected by measuring PPG and accelerometer data, as well as electrocardiogram as a reference, during 24-hour monitoring. The dataset was split into 75%-25% for training and testing a Random Forest (RF) model, which combines features from PPG, inter-pulse intervals (IPI), and accelerometer data, to classify AF, AFL, and other rhythms. The performance was compared to an AF detection algorithm combining traditional IPI features for determining the robustness of the accuracy in presence of AFL. RESULTS The RF model classified AF/AFL/other with sensitivity and specificity of 97.6/84.5/98.1% and 98.2/99.7/92.8%, respectively. The results with the IPI-based AF classifier showed that the majority of false detections were caused by AFL. CONCLUSION The PPG signal contains information to classify AFL in the presence of AF, sinus rhythm, or sinus rhythm with premature contractions. SIGNIFICANCE PPG could indicate presence of AFL, not only AF.
Collapse
|