Ravagli E, Ardell J, Holder D, Aristovich K. A combined cuff electrode array for organ-specific selective stimulation of vagus nerve enabled by Electrical Impedance Tomography. FRONTIERS IN MEDICAL TECHNOLOGY 2023; 5:1122016. [PMID: 37138728 PMCID: PMC10149952 DOI: 10.3389/fmedt.2023.1122016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2022] [Accepted: 03/20/2023] [Indexed: 05/05/2023] Open
Abstract
Previously developed spatially-selective Vagus Nerve Stimulation (sVNS) allows the targeting of specific nerve fascicles through current steering in a multi-electrode nerve cuff but relies on a trial-and-error strategy to identify the relative orientation between electrodes and fascicles. Fast Neural Electrical Impedance Tomography (FN-EIT) has been recently used for imaging neural traffic in the vagus nerves of pigs in a cross-correlation study with sVNS and MicroCT fascicle tracking. FN-EIT has the potential for allowing targeted sVNS; however, up to now, stimulation and imaging have been performed with separate electrode arrays. In this study, different options were evaluated in-silico to integrate EIT and stimulation into a single electrode array without affecting spatial selectivity. The original pig vagus EIT electrode array geometry was compared with a geometry integrating sVNS and EIT electrodes, and with direct use of sVNS electrodes for EIT imaging. Modelling results indicated that both new designs could achieve image quality similar to the original electrode geometry in all tested markers (e.g., co-localisation error <100 µm). The sVNS array was considered to be the simplest due to the lower number of electrodes. Experimental results from testing evoked EIT imaging of recurrent laryngeal activity using electrodes from the sVNS cuff returned a signal-to-noise ratio similar to our previous study (3.9 ± 2.4 vs. 4.1 ± 1.5, N = 4 nerves from 3 pigs) and a lower co-localisation error (≈14% nerve diameter vs. ≈25%, N = 2 nerves from 2 pigs). Performing FN-EIT and sVNS on the same nerve cuff will facilitate translation to humans, simplify surgery and enable targeted neuromodulation strategies.
Collapse
Affiliation(s)
- Enrico Ravagli
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
- Correspondence: Enrico Ravagli
| | - Jeffrey Ardell
- Department of Medicine, CardiacArrhythmia Centre, University of California Los Angeles, Los Angeles, CA, United States
| | - David Holder
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | - Kirill Aristovich
- Department of Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| |
Collapse
|
2
|
Wang L, Zhu W, Wang R, Li W, Liang G, Ji Z, Dong X, Shi X. Suppressing interferences of EIT on synchronous recording EEG based on comb filter for seizure detection. Front Neurol 2022; 13:1070124. [DOI: 10.3389/fneur.2022.1070124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Accepted: 11/18/2022] [Indexed: 12/03/2022] Open
Abstract
Background and objectiveThe purpose of this study was to eliminate the interferences of electrical impedance tomography (EIT) on synchronous recording electroencephalography (EEG) for seizure detection.MethodsThe simulated EIT signal generated by COMSOL Multiphysics was superimposed on the clinical EEG signal obtained from the CHB-MIT Scalp EEG Database, and then the spectrum features of superimposed mixed signals were analyzed. According to the spectrum analysis, in addition to high-frequency interference at 51.2 kHz related to the drive current, there was also low-frequency interference caused by switching of electrode pairs, which were used to inject drive current. A low pass filter and a comb filter were used to suppress the high-frequency interference and low-frequency interference, respectively. Simulation results suggested the low-pass filter and comb filter working together effectively filtered out the interference of EIT on EEG in the process of synchronous monitoring.ResultsAs a result, the normal EEG and epileptic EEG could be recognized effectively. Pearson correlation analysis further confirmed the interference of EIT on EEG was effectively suppressed.ConclusionsThis study provides a simple and effective interference suppression method for the synchronous monitoring of EIT and EEG, which could be served as a reference for the synchronous monitoring of EEG and other medical electromagnetic devices.
Collapse
|
3
|
Ke XY, Hou W, Huang Q, Hou X, Bao XY, Kong WX, Li CX, Qiu YQ, Hu SY, Dong LH. Advances in electrical impedance tomography-based brain imaging. Mil Med Res 2022; 9:10. [PMID: 35227324 PMCID: PMC8883715 DOI: 10.1186/s40779-022-00370-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2021] [Accepted: 02/08/2022] [Indexed: 11/10/2022] Open
Abstract
Novel advances in the field of brain imaging have enabled the unprecedented clinical application of various imaging modalities to facilitate disease diagnosis and treatment. Electrical impedance tomography (EIT) is a functional imaging technique that measures the transfer impedances between electrodes on the body surface to estimate the spatial distribution of electrical properties of tissues. EIT offers many advantages over other neuroimaging technologies, which has led to its potential clinical use. This qualitative review provides an overview of the basic principles, algorithms, and system composition of EIT. Recent advances in the field of EIT are discussed in the context of epilepsy, stroke, brain injuries and edema, and other brain diseases. Further, we summarize factors limiting the development of brain EIT and highlight prospects for the field. In epilepsy imaging, there have been advances in EIT imaging depth, from cortical to subcortical regions. In stroke research, a bedside EIT stroke monitoring system has been developed for clinical practice, and data support the role of EIT in multi-modal imaging for diagnosing stroke. Additionally, EIT has been applied to monitor the changes in brain water content associated with cerebral edema, enabling the early identification of brain edema and the evaluation of mannitol dehydration. However, anatomically realistic geometry, inhomogeneity, cranium completeness, anisotropy and skull type, etc., must be considered to improve the accuracy of EIT modeling. Thus, the further establishment of EIT as a mature and routine diagnostic technique will necessitate the accumulation of more supporting evidence.
Collapse
Affiliation(s)
- Xi-Yang Ke
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Qi Huang
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China
| | - Xue Hou
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Xue-Ying Bao
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Wei-Xuan Kong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China
| | - Cheng-Xiang Li
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Yu-Qi Qiu
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China.,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China.,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China
| | - Si-Yi Hu
- CAS Key Laboratory of Bio-Medical Diagnostics, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, 215163, Jiangsu, China.
| | - Li-Hua Dong
- Department of Radiation Oncology and Therapy, The First Hospital of Jilin University, 130021, Changchun, China. .,Jilin Provincial Key Laboratory of Radiation Oncology and Therapy, The First Hospital of Jilin University, Changchun, 130021, China. .,NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, 130021, China.
| |
Collapse
|
5
|
Evaluation of Thoracic Equivalent Multiport Circuits Using an Electrical Impedance Tomography Hardware Simulation Interface. TECHNOLOGIES 2021. [DOI: 10.3390/technologies9030058] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Electrical impedance tomography is a low-cost, safe, and high temporal resolution medical imaging modality which finds extensive application in real-time thoracic impedance imaging. Thoracic impedance changes can reveal important information about the physiological condition of patients’ lungs. In this way, electrical impedance tomography can be a valuable tool for monitoring patients. However, this technique is very sensitive to measurement noise or possible minor signal errors, coming from either the hardware, the electrodes, or even particular biological signals. Thus, the design of a good performance electrical impedance tomography hardware setup which properly interacts with the tissue examined is both an essential and a challenging concept. In this paper, we adopt an extensive simulation approach, which combines the system’s analogue and digital hardware, along with equivalent circuits of 3D finite element models that represent thoracic cavities. Each thoracic finite element model is created in MATLAB based on existing CT images, while the tissues’ conductivity and permittivity values for a selected frequency are acquired from a database using Python. The model is transferred to a multiport RLC network, embedded in the system’s hardware which is simulated at LT SPICE. The voltage output data are transferred to MATLAB where the electrical impedance tomography signal sampling and digital processing is also simulated. Finally, image reconstructions are performed in MATLAB, using the EIDORS library tool and considering the signal noise levels and different electrode and signal sampling configurations (ADC bits, sampling frequency, number of taps).
Collapse
|
6
|
Witkowska-Wrobel A, Aristovich K, Crawford A, Perkins JD, Holder D. Imaging of focal seizures with Electrical Impedance Tomography and depth electrodes in real time. Neuroimage 2021; 234:117972. [PMID: 33757909 PMCID: PMC8204270 DOI: 10.1016/j.neuroimage.2021.117972] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2020] [Revised: 01/31/2021] [Accepted: 03/12/2021] [Indexed: 11/26/2022] Open
Abstract
Intracranial EEG is the current gold standard technique for localizing seizures for surgery, but it can be insensitive to tangential dipole or distant sources. Electrical Impedance Tomography (EIT) offers a novel method to improve coverage and seizure onset localization. The feasibility of EIT has been previously assessed in a computer simulation, which revealed an improved accuracy of seizure detection with EIT compared to intracranial EEG. In this study, slow impedance changes, evoked by cell swelling occurring over seconds, were reconstructed in real time by frequency division multiplexing EIT using depth and subdural electrodes in a swine model of epilepsy. EIT allowed to generate repetitive images of ictal events at similar time course to fMRI but without its significant limitations. EIT was recorded with a system consisting of 32 parallel current sources and 64 voltage recorders. Seizures triggered with intracranial injection of benzylpenicillin (BPN) in five pigs caused a repetitive peak impedance increase of 3.4 ± 1.5 mV and 9.5 ± 3% (N =205 seizures); the impedance signal change was seen already after a single, first seizure. EIT enabled reconstruction of the seizure onset 9 ± 1.5 mm from the BPN cannula and 7.5 ± 1.1 mm from the closest SEEG contact (p<0.05, n =37 focal seizures in three pigs) and it could address problems with sampling error in intracranial EEG. The amplitude of the impedance change correlated with the spread of the seizure on the SEEG (p <<0.001, n =37). The results presented here suggest that combining a parallel EIT system with intracranial EEG monitoring has a potential to improve the diagnostic yield in epileptic patients and become a vital tool in improving our understanding of epilepsy.
Collapse
Affiliation(s)
| | - Kirill Aristovich
- Medical Physics and Biomedical Engineering, University College London, UK
| | - Abbe Crawford
- Royal Veterinary College, Hawkshead Lane, North Mymms, Hatfield, Hertfordshire AL9 7TA, UK
| | - Justin D Perkins
- Royal Veterinary College, Hawkshead Lane, North Mymms, Hatfield, Hertfordshire AL9 7TA, UK
| | - David Holder
- Medical Physics and Biomedical Engineering, University College London, UK
| |
Collapse
|
7
|
Hannan S, Aristovich K, Faulkner M, Avery J, Walker MC, Holder DS. Imaging slow brain activity during neocortical and hippocampal epileptiform events with electrical impedance tomography. Physiol Meas 2021; 42:014001. [PMID: 33361567 DOI: 10.1088/1361-6579/abd67a] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
OBJECTIVE Electrical impedance tomography (EIT) is an imaging technique that produces tomographic images of internal impedance changes within an object using surface electrodes. It can be used to image the slow increase in cerebral tissue impedance that occurs over seconds during epileptic seizures, which is attributed to cell swelling due to disturbances in ion homeostasis following hypersynchronous neuronal firing and its associated metabolic demands. In this study, we characterised and imaged this slow impedance response during neocortical and hippocampal epileptiform events in the rat brain and evaluated its relationship to the underlying neural activity. APPROACH Neocortical or hippocampal seizures, comprising repeatable series of high-amplitude ictal spikes, were induced by electrically stimulating the sensorimotor cortex or perforant path of rats anaesthetised with fentanyl-isoflurane. Transfer impedances were measured during ≥30 consecutive seizures, by applying a sinusoidal current through independent electrode pairs on an epicortical array, and combined to generate an EIT image of slow activity. MAIN RESULTS The slow impedance responses were consistently time-matched to the end of seizures and EIT images of this activity were reconstructed reproducibly in all animals (p < 0.03125, N = 5). These displayed foci of activity that were spatially confined to the facial somatosensory cortex and dentate gyrus for neocortical and hippocampal seizures, respectively, and encompassed a larger volume as the seizure progressed. Centre-of-mass analysis of reconstructions revealed that this activity corresponded to the true location of the epileptogenic zone, as determined by EEG recordings and fast neural EIT measurements which were obtained simultaneously. SIGNIFICANCE These findings suggest that the slow impedance response presents a reliable marker of hypersynchronous neuronal activity during epileptic seizures and can thus be utilised for investigating the mechanisms of epileptogenesis in vivo and for aiding localisation of the epileptogenic zone during presurgical evaluation of patients with refractory epilepsies.
Collapse
Affiliation(s)
- Sana Hannan
- Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| | - Kirill Aristovich
- Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| | - Mayo Faulkner
- Wolfson Institute for Biomedical Research, University College London, United Kingdom
| | - James Avery
- Department of Surgery and Cancer, Imperial College London, United Kingdom
| | - Matthew C Walker
- UCL Queen Square Institute of Neurology, University College London, United Kingdom
| | - David S Holder
- Department of Medical Physics and Biomedical Engineering, University College London, United Kingdom
| |
Collapse
|
9
|
Abstract
In this paper a number of LT Spice simulations have been carried out on an Electrical Impedance Tomography (EIT) system, which includes the whole analog and digital circuitry as well as the subject to be examined (phantom model). The aim of this study is to show how the analog and digital parts, the electrodes and the subject’s physical properties may impact the measurements and the quality of the reconstructed image. This could provide a useful tool for designing an EIT system. Special attention has been given to the current source’s output impedance and swing, to the noise produced by the circuits and to the Analog to Digital Converters (ADCs) resolution and sampling rate. Furthermore, some 3D phantom subjects have been modeled and simulated as equivalent circuits, merged with the EIT simulated hardware, in order to observe how changes on their properties interact with the whole circuitry and affect the final result. Observations show that mirrored current sources with z o u t > 350 k Ω and sufficiently high ADC acquisition sampling rate ( f s a m p l e ≥ 16 f i n ) can result to accurate impedance measurements and therefore quality image reconstruction within a frequency span of at least 10 to 100 kHz. Moreover, possible hardware failures (electrode disconnections and imbalanced contact impedances) can be detected with a simple examination of the first extracted image and measurement set, so that by direct modification of the reconstruction process, a corrected result can be obtained.
Collapse
|
10
|
McDermott B, O'Halloran M, Avery J, Porter E. Bi-Frequency Symmetry Difference EIT-Feasibility and Limitations of Application to Stroke Diagnosis. IEEE J Biomed Health Inform 2019; 24:2407-2419. [PMID: 31869810 DOI: 10.1109/jbhi.2019.2960862] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE Bi-Frequency Symmetry Difference (BFSD)-EIT can detect, localize and identify unilateral perturbations in symmetric scenes. Here, we test the viability and robustness of BFSD-EIT in stroke diagnosis. METHODS A realistic 4-layer Finite Element Method (FEM) head model with and without bleed and clot lesions is developed. Performance is assessed with test parameters including: measurement noise, electrode placement errors, contact impedance errors, deviations in assumed tissue conductivity, deviations in assumed anatomy, and a frequency-dependent background. A final test is performed using ischemic patient data. Results are assessed using images and quantitative metrics. RESULTS BFSD-EIT may be feasible for stroke diagnosis if a signal-to-noise ratio (SNR) of ≥60 dB is achievable. Sensitivity to errors in electrode positioning is seen with a tolerance of only ±5 mm, but a tolerance of up to ±30 mm is possible if symmetry is maintained between symmetrically opposite partner electrodes. The technique is robust to errors in contact impedance and assumed tissue conductivity up to at least ±50%. Asymmetric internal anatomy affects performance but may be tolerable for tissues with frequency-dependent conductivity. Errors in assumed external geometry marginally affect performance. A frequency-dependent background does not affect performance with carefully chosen frequency points or use of multiple frequency points across a band. The Global Left-Hand Side (LHS) & Right-Hand Side (RHS) Mean Intensity metric is particularly robust to errors. CONCLUSION BFSD-EIT is a promising technique for stroke diagnosis, provided parameters are within the tolerated ranges. SIGNIFICANCE BFSD-EIT may prove an important step forward in imaging of static scenes such as stroke.
Collapse
|
11
|
Ravagli E, Mastitskaya S, Thompson N, Aristovich K, Holder D. Optimization of the electrode drive pattern for imaging fascicular compound action potentials in peripheral nerve with fast neural electrical impedance tomography. Physiol Meas 2019; 40:115007. [PMID: 31694004 PMCID: PMC7214787 DOI: 10.1088/1361-6579/ab54eb] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVE The main objective of this study was to investigate which injection pattern led to the best imaging of fascicular compound activity in fast neural EIT of peripheral nerve using an external cylindrical 2 × 14-electrodes cuff. Specifically, the study addressed the identification of the optimal injection pattern and of the optimal region of the reconstructed volume to image fascicles. APPROACH The effect of three different measurement protocol features (transversal/longitudinal injection, drive electrode spacing, referencing configuration) over imaging was investigated in simulation with the use of realistic impedance changes and noise levels. Image-based metrics were employed to evaluate the quality of the reconstructions over the reconstruction domain. The optimal electrode addressing protocol suggested by the simulations was validated in vivo on the tibial and peroneal fascicles of rat sciatic peripheral nerves (N = 3) against MicroCT reference images. MAIN RESULTS Injecting current transversally, with spacing of ⩾4 electrodes apart (⩾100°) and single-ring referencing of measurements, led to the best overall localization when reconstructing on the edge of the electrode array closest to the reference. Longitudinal injection protocols led to a higher SNR of the reconstructed image but poorer localization. All in vivo EIT recordings had statistically significant impedance variations (p < 0.05). Overall, fascicle center-of-mass (CoM) localization error was estimated at 141 ± 56 µm (-26 ± 94 µm and 5 ± 29° in radial coordinates). Significant difference was found (p < 0.05) between mean angular location of the tibial and peroneal CoMs. SIGNIFICANCE This study gives the reader recommendations for performing fast neural EIT of fascicular compound activity using the most effective protocol features.
Collapse
Affiliation(s)
- Enrico Ravagli
- Medical Physics and Biomedical Engineering, University College London, London, United Kingdom
| | | | | | | | | |