1
|
Liu XY, Wang WL, Liu M, Chen MY, Pereira T, Doda DY, Ke YF, Wang SY, Wen D, Tong XG, Li WG, Yang Y, Han XD, Sun YL, Song X, Hao CY, Zhang ZH, Liu XY, Li CY, Peng R, Song XX, Yasi A, Pang MJ, Zhang K, He RN, Wu L, Chen SG, Chen WJ, Chao YG, Hu CG, Zhang H, Zhou M, Wang K, Liu PF, Chen C, Geng XY, Qin Y, Gao DR, Song EM, Cheng LL, Chen X, Ming D. Recent applications of EEG-based brain-computer-interface in the medical field. Mil Med Res 2025; 12:14. [PMID: 40128831 PMCID: PMC11931852 DOI: 10.1186/s40779-025-00598-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Accepted: 02/21/2025] [Indexed: 03/26/2025] Open
Abstract
Brain-computer interfaces (BCIs) represent an emerging technology that facilitates direct communication between the brain and external devices. In recent years, numerous review articles have explored various aspects of BCIs, including their fundamental principles, technical advancements, and applications in specific domains. However, these reviews often focus on signal processing, hardware development, or limited applications such as motor rehabilitation or communication. This paper aims to offer a comprehensive review of recent electroencephalogram (EEG)-based BCI applications in the medical field across 8 critical areas, encompassing rehabilitation, daily communication, epilepsy, cerebral resuscitation, sleep, neurodegenerative diseases, anesthesiology, and emotion recognition. Moreover, the current challenges and future trends of BCIs were also discussed, including personal privacy and ethical concerns, network security vulnerabilities, safety issues, and biocompatibility.
Collapse
Affiliation(s)
- Xiu-Yun Liu
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
- Haihe Laboratory of Brain-Computer Interaction and Human-Machine Integration, Tianjin, 300380, China
- School of Pharmaceutical Science and Technology, Tianjin University, Tianjin, 300072, China
| | - Wen-Long Wang
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Miao Liu
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Ming-Yi Chen
- Department of Micro/Nano Electronics, Shanghai Jiaotong University, Shanghai, 200240, China
| | - Tânia Pereira
- Institute for Systems and Computer Engineering, Technology and Science, 4099-002, Porto, Portugal
| | - Desta Yakob Doda
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Yu-Feng Ke
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Shou-Yan Wang
- Institute of Science and Technology for Brain-Inspired Intelligence, Fudan University, Shanghai, 200433, China
| | - Dong Wen
- School of Intelligence Science and Technology, University of Sciences and Technology Beijing, Beijing, 100083, China
| | | | - Wei-Guang Li
- The State Key Laboratory of Brain and Cognitive Sciences, The University of Hong Kong, Hong Kong SAR, 999077, China
- State Key Laboratory for Quality Ensurance and Sustainable Use of Dao-Di Herbs, Artemisinin Research Center, and Institute of Chinese Materia Medica, China Academy of Chinese Medical Sciences, Beijing, 100700, China
| | - Yi Yang
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China
- China National Clinical Research Center for Neurological Diseases, Beijing, 100070, China
- Medical Research Council Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, OX1 3TH, UK
| | - Xiao-Di Han
- Department of Neurosurgery, Beijing Tiantan Hospital, Capital Medical University, Beijing, 100070, China
| | - Yu-Lin Sun
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Xin Song
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Cong-Ying Hao
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Zi-Hua Zhang
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Xin-Yang Liu
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Chun-Yang Li
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Rui Peng
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Xiao-Xin Song
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Abi Yasi
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Mei-Jun Pang
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Kuo Zhang
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Run-Nan He
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Le Wu
- Department of Electric Engineering and Information Science, University of Science and Technology of China, Hefei, 230026, China
| | - Shu-Geng Chen
- Department of Rehabilitation, Huashan Hospital, Fudan University, Shanghai, 200040, China
| | - Wen-Jin Chen
- Xuanwu Hospital of Capital Medical University, Beijing, 100053, China
| | - Yan-Gong Chao
- The First Hospital of Tsinghua University, Beijing, 100016, China
| | - Cheng-Gong Hu
- Department of Critical Care Medicine, West China Hospital of Sichuan University, Chengdu, 610041, China
| | - Heng Zhang
- Department of Neurosurgery, The First Hospital of China Medical University, Beijing, 110122, China
| | - Min Zhou
- Department of Critical Care Medicine, Division of Life Sciences and Medicine, The First Affiliated Hospital of University of Science and Technology of China, University of Science and Technology of China, Hefei, 230031, China
| | - Kun Wang
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Peng-Fei Liu
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China
| | - Chen Chen
- School of Computer Science, Fudan University, Shanghai, 200438, China
| | - Xin-Yi Geng
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - Yun Qin
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - Dong-Rui Gao
- School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, 611731, China
| | - En-Ming Song
- Shanghai Frontiers Science Research Base of Intelligent Optoelectronics and Perception, Institute of Optoelectronics, Fudan University, Shanghai, 200433, China
| | - Long-Long Cheng
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China.
| | - Xun Chen
- Department of Electric Engineering and Information Science, University of Science and Technology of China, Hefei, 230026, China.
| | - Dong Ming
- State Key Laboratory of Advanced Medical Materials and Devices, Medical School, Tianjin University, Tianjin, 300072, China.
- Haihe Laboratory of Brain-Computer Interaction and Human-Machine Integration, Tianjin, 300380, China.
| |
Collapse
|
4
|
Lucas A, Revell A, Davis KA. Artificial intelligence in epilepsy - applications and pathways to the clinic. Nat Rev Neurol 2024; 20:319-336. [PMID: 38720105 DOI: 10.1038/s41582-024-00965-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/16/2024] [Indexed: 06/06/2024]
Abstract
Artificial intelligence (AI) is rapidly transforming health care, and its applications in epilepsy have increased exponentially over the past decade. Integration of AI into epilepsy management promises to revolutionize the diagnosis and treatment of this complex disorder. However, translation of AI into neurology clinical practice has not yet been successful, emphasizing the need to consider progress to date and assess challenges and limitations of AI. In this Review, we provide an overview of AI applications that have been developed in epilepsy using a variety of data modalities: neuroimaging, electroencephalography, electronic health records, medical devices and multimodal data integration. For each, we consider potential applications, including seizure detection and prediction, seizure lateralization, localization of the seizure-onset zone and assessment for surgical or neurostimulation interventions, and review the performance of AI tools developed to date. We also discuss methodological considerations and challenges that must be addressed to successfully integrate AI into clinical practice. Our goal is to provide an overview of the current state of the field and provide guidance for leveraging AI in future to improve management of epilepsy.
Collapse
Affiliation(s)
- Alfredo Lucas
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Andrew Revell
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA
| | - Kathryn A Davis
- Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.
- Department of Neurology, University of Pennsylvania, Philadelphia, PA, USA.
| |
Collapse
|
5
|
Chung YG, Cho A, Kim H, Kim KJ. Single-channel seizure detection with clinical confirmation of seizure locations using CHB-MIT dataset. Front Neurol 2024; 15:1389731. [PMID: 38836000 PMCID: PMC11148866 DOI: 10.3389/fneur.2024.1389731] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2024] [Accepted: 05/03/2024] [Indexed: 06/06/2024] Open
Abstract
Introduction Long-term electroencephalography (EEG) monitoring is advised to patients with refractory epilepsy who have a failure of anti-seizure medication and therapy. However, its real-life application is limited mainly due to the use of multiple EEG channels. We proposed a patient-specific deep learning-based single-channel seizure detection approach using the long-term scalp EEG recordings of the Children's Hospital Boston-Massachusetts Institute of Technology (CHB-MIT) dataset, in conjunction with neurologists' confirmation of spatial seizure characteristics of individual patients. Methods We constructed 18-, 4-, and single-channel seizure detectors for 13 patients. Neurologists selected a specific channel among four channels, two close to the behind-the-ear and two at the forehead for each patient, after reviewing the patient's distinctive seizure locations with seizure re-annotation. Results Our multi- and single-channel detectors achieved an average sensitivity of 97.05-100%, false alarm rate of 0.22-0.40/h, and latency of 2.1-3.4 s for identification of seizures in continuous EEG recordings. The results demonstrated that seizure detection performance of our single-channel approach was comparable to that of our multi-channel ones. Discussion We suggest that our single-channel approach in conjunction with clinical designation of the most prominent seizure locations has a high potential for wearable seizure detection on long-term EEG recordings for patients with refractory epilepsy.
Collapse
Affiliation(s)
- Yoon Gi Chung
- Department of Pediatrics, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Anna Cho
- Department of Pediatrics, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam-si, Gyeonggi-do, Republic of Korea
| | - Hunmin Kim
- Department of Pediatrics, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam-si, Gyeonggi-do, Republic of Korea
- Department of Pediatrics, Seoul National University College of Medicine, Seoul, Republic of Korea
| | - Ki Joong Kim
- Department of Pediatrics, Seoul National University Children's Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea
| |
Collapse
|
6
|
Ali E, Angelova M, Karmakar C. Epileptic seizure detection using CHB-MIT dataset: The overlooked perspectives. ROYAL SOCIETY OPEN SCIENCE 2024; 11:230601. [PMID: 39076791 PMCID: PMC11286169 DOI: 10.1098/rsos.230601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 11/23/2023] [Accepted: 03/28/2024] [Indexed: 07/31/2024]
Abstract
Epilepsy is a life-threatening neurological condition. Manual detection of epileptic seizures (ES) is laborious and burdensome. Machine learning techniques applied to electroencephalography (EEG) signals are widely used for automatic seizure detection. Some key factors are worth considering for the real-world applicability of such systems: (i) continuous EEG data typically has a higher class imbalance; (ii) higher variability across subjects is present in physiological signals such as EEG; and (iii) seizure event detection is more practical than random segment detection. Most prior studies failed to address these crucial factors altogether for seizure detection. In this study, we intend to investigate a generalized cross-subject seizure event detection system using the continuous EEG signals from the CHB-MIT dataset that considers all these overlooked aspects. A 5-second non-overlapping window is used to extract 92 features from 22 EEG channels; however, the most significant 32 features from each channel are used in experimentation. Seizure classification is done using a Random Forest (RF) classifier for segment detection, followed by a post-processing method used for event detection. Adopting all the above-mentioned essential aspects, the proposed event detection system achieved 72.63% and 75.34% sensitivity for subject-wise 5-fold and leave-one-out analyses, respectively. This study presents the real-world scenario for ES event detectors and furthers the understanding of such detection systems.
Collapse
Affiliation(s)
- Emran Ali
- School of Information Technology, Deakin University, Melbourne Burwood Campus, Melbourne, Victoria3125, Australia
| | - Maia Angelova
- School of Information Technology, Deakin University, Melbourne Burwood Campus, Melbourne, Victoria3125, Australia
- Aston Digital Futures Institute, EPS, Aston University, Birmingham, UK
- Institute of Biophysics and Biomedical Engineering, Bulgarian Academy of Sciences, Sofia, Bulgaria
| | - Chandan Karmakar
- School of Information Technology, Deakin University, Melbourne Burwood Campus, Melbourne, Victoria3125, Australia
| |
Collapse
|