1
|
Martin JR, Gabriel P, Gold J, Haas R, Davis S, Gonda D, Sharpe C, Wilson S, Nierenberg N, Scheuer M, Wang S. Optical Flow Estimation Improves Automated Seizure Detection in Neonatal EEG. J Clin Neurophysiol 2022; 39:235-239. [PMID: 32810002 PMCID: PMC7887141 DOI: 10.1097/wnp.0000000000000767] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
PURPOSE Existing automated seizure detection algorithms report sensitivities between 43% and 77% and specificities between 56% and 90%. The algorithms suffer from false alarms when applied to neonatal EEG because of the high degree of nurse handling and rhythmic patting used to soothe neonates. Computer vision technology that quantifies movement in real time could distinguish artifactual motion and improve automated neonatal seizure detection algorithms. METHODS The authors used video EEG recordings from 43 neonates undergoing monitoring for seizures as part of the NEOLEV2 clinical trial. The Persyst neonatal automated seizure detection algorithm ran in real time during study EEG acquisitions. Computer vision algorithms were applied to extract detailed accounts of artifactual movement of the neonate or people near the neonate though dense optical flow estimation. RESULTS Using the methods mentioned above, 197 periods of patting activity were identified and quantified, of which 45 generated false-positive automated seizure detection events. A binary patting detection algorithm was trained with a subset of 470 event videos. This supervised detection algorithm was applied to a testing subset of 187 event videos with 8 false-positive events, which resulted in a 24% reduction in false-positive automated seizure detections and a 50% reduction in false-positive events caused by neonatal care patting, while maintaining 11 of 12 true-positive seizure detection events. CONCLUSIONS This work presents a novel approach to improving automated seizure detection algorithms used during neonatal video EEG monitoring. This artifact detection mechanism can improve the ability of a seizure detector algorithm to distinguish between artifact and true seizure activity.
Collapse
Affiliation(s)
- Joel R Martin
- Department of Electrical Engineering, University of California, San Diego, La Jolla, CA
| | - Paolo Gabriel
- Department of Electrical Engineering, University of California, San Diego, La Jolla, CA
| | - Jeffrey Gold
- Department of Neurosciences, University of California, San Diego, La Jolla, CA
| | - Richard Haas
- Department of Pediatrics, University of California, San Diego, La Jolla, CA
| | - Sue Davis
- Auckland District Health Board, Auckland, New Zealand
| | - David Gonda
- Department of Surgery, University of California, San Diego, La Jolla, CA
| | - Cia Sharpe
- Department of Pediatrics, University of California, San Diego, La Jolla, CA
| | | | | | | | - Sonya Wang
- Department of Neurology, University of Minnesota, Minneapolis, MN
| |
Collapse
|
2
|
Webb L, Kauppila M, Roberts JA, Vanhatalo S, Stevenson NJ. Automated detection of artefacts in neonatal EEG with residual neural networks. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2021; 208:106194. [PMID: 34118491 DOI: 10.1016/j.cmpb.2021.106194] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Accepted: 05/17/2021] [Indexed: 06/12/2023]
Abstract
BACKGROUND AND OBJECTIVE To develop a computational algorithm that detects and identifies different artefact types in neonatal electroencephalography (EEG) signals. METHODS As part of a larger algorithm, we trained a Residual Deep Neural Network on expert human annotations of EEG recordings from 79 term infants recorded in a neonatal intensive care unit (112 h of 18-channel recording). The network was trained using 10 fold cross validation in Matlab. Artefact types included: device interference, EMG, movement, electrode pop, and non-cortical biological rhythms. Performance was assessed by prediction statistics and further validated on a separate independent dataset of 13 term infants (143 h of 3-channel recording). EEG pre-processing steps, and other post-processing steps such as averaging probability over a temporal window, were also included in the algorithm. RESULTS The Residual Deep Neural Network showed high accuracy (95%) when distinguishing periods of clean, artefact-free EEG from any kind of artefact, with a median accuracy for individual patient of 91% (IQR: 81%-96%). The accuracy in identifying the five different types of artefacts ranged from 57%-92%, with electrode pop being the hardest to detect and EMG being the easiest. This reflected the proportion of artefact available in the training dataset. Misclassification as clean was low for each artefact type, ranging from 1%-11%. The detection accuracy was lower on the validation set (87%). We used the algorithm to show that EEG channels located near the vertex were the least susceptible to artefact. CONCLUSION Artefacts can be accurately and reliably identified in the neonatal EEG using a deep learning algorithm. Artefact detection algorithms can provide continuous bedside quality assessment and support EEG review by clinicians or analysis algorithms.
Collapse
Affiliation(s)
- Lachlan Webb
- Brain Modelling Group, QIMR Berghofer Medical Research Institute, Brisbane, QLD, Australia; Faculty of Medicine, University of Queensland, Brisbane, QLD, Australia.
| | - Minna Kauppila
- BABA center, Department of Children's Clinical Neurophysiology, Children's hospital, HUS Medical Imaging center, Neuroscience center, Helsinki Institute of Life Science, Helsinki University Central Hospital and University of Helsinki, Finland; Medical Imaging and Radiation Therapy, Kymenlaakso Central Hospital, Kotka, Finland
| | - James A Roberts
- Brain Modelling Group, QIMR Berghofer Medical Research Institute, Brisbane, QLD, Australia; Faculty of Medicine, University of Queensland, Brisbane, QLD, Australia.
| | - Sampsa Vanhatalo
- BABA center, Department of Children's Clinical Neurophysiology, Children's hospital, HUS Medical Imaging center, Neuroscience center, Helsinki Institute of Life Science, Helsinki University Central Hospital and University of Helsinki, Finland.
| | - Nathan J Stevenson
- Brain Modelling Group, QIMR Berghofer Medical Research Institute, Brisbane, QLD, Australia; BABA center, Department of Children's Clinical Neurophysiology, Children's hospital, HUS Medical Imaging center, Neuroscience center, Helsinki Institute of Life Science, Helsinki University Central Hospital and University of Helsinki, Finland.
| |
Collapse
|
3
|
Abbasi H, Unsworth CP. Applications of advanced signal processing and machine learning in the neonatal hypoxic-ischemic electroencephalogram. Neural Regen Res 2020; 15:222-231. [PMID: 31552887 PMCID: PMC6905345 DOI: 10.4103/1673-5374.265542] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Accepted: 05/24/2019] [Indexed: 01/15/2023] Open
Abstract
Perinatal hypoxic-ischemic-encephalopathy significantly contributes to neonatal death and life-long disability such as cerebral palsy. Advances in signal processing and machine learning have provided the research community with an opportunity to develop automated real-time identification techniques to detect the signs of hypoxic-ischemic-encephalopathy in larger electroencephalography/amplitude-integrated electroencephalography data sets more easily. This review details the recent achievements, performed by a number of prominent research groups across the world, in the automatic identification and classification of hypoxic-ischemic epileptiform neonatal seizures using advanced signal processing and machine learning techniques. This review also addresses the clinical challenges that current automated techniques face in order to be fully utilized by clinicians, and highlights the importance of upgrading the current clinical bedside sampling frequencies to higher sampling rates in order to provide better hypoxic-ischemic biomarker detection frameworks. Additionally, the article highlights that current clinical automated epileptiform detection strategies for human neonates have been only concerned with seizure detection after the therapeutic latent phase of injury. Whereas recent animal studies have demonstrated that the latent phase of opportunity is critically important for early diagnosis of hypoxic-ischemic-encephalopathy electroencephalography biomarkers and although difficult, detection strategies could utilize biomarkers in the latent phase to also predict the onset of future seizures.
Collapse
Affiliation(s)
- Hamid Abbasi
- Department of Engineering Science, The University of Auckland, Auckland, New Zealand
| | - Charles P. Unsworth
- Department of Engineering Science, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
4
|
Pillay K, Dereymaeker A, Jansen K, Naulaers G, Van Huffel S, De Vos M. Automated EEG sleep staging in the term-age baby using a generative modelling approach. J Neural Eng 2018; 15:036004. [DOI: 10.1088/1741-2552/aaab73] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
|
5
|
Abbasi H, Bennet L, Gunn AJ, Unsworth CP. Robust Wavelet Stabilized 'Footprints of Uncertainty' for Fuzzy System Classifiers to Automatically Detect Sharp Waves in the EEG after Hypoxia Ischemia. Int J Neural Syst 2016; 27:1650051. [PMID: 27760476 DOI: 10.1142/s0129065716500519] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Currently, there are no developed methods to detect sharp wave transients that exist in the latent phase after hypoxia-ischemia (HI) in the electroencephalogram (EEG) in order to determine if these micro-scale transients are potential biomarkers of HI. A major issue with sharp waves in the HI-EEG is that they possess a large variability in their sharp wave profile making it difficult to build a compact 'footprint of uncertainty' (FOU) required for ideal performance of a Type-2 fuzzy logic system (FLS) classifier. In this paper, we develop a novel computational EEG analysis method to robustly detect sharp waves using over 30[Formula: see text]h of post occlusion HI-EEG from an equivalent, in utero, preterm fetal sheep model cohort. We demonstrate that initial wavelet transform (WT) of the sharp waves stabilizes the variation in their profile and thus permits a highly compact FOU to be built, hence, optimizing the performance of a Type-2 FLS. We demonstrate that this method leads to higher overall performance of [Formula: see text] for the clinical [Formula: see text] sampled EEG and [Formula: see text] for the high resolution [Formula: see text] sampled EEG that is improved upon over conventional standard wavelet [Formula: see text] and [Formula: see text], respectively, and fuzzy approaches [Formula: see text] and [Formula: see text], respectively, when performed in isolation.
Collapse
Affiliation(s)
- Hamid Abbasi
- 1 Department of Engineering Science, The University of Auckland, Auckland, New Zealand
| | - Laura Bennet
- 2 Department of Physiology, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Alistair J Gunn
- 2 Department of Physiology, Faculty of Medical and Health Sciences, The University of Auckland, Auckland, New Zealand
| | - Charles P Unsworth
- 1 Department of Engineering Science, The University of Auckland, Auckland, New Zealand
| |
Collapse
|
6
|
Nagaraj SB, Stevenson NJ, Marnane WP, Boylan GB, Lightbody G. Neonatal seizure detection using atomic decomposition with a novel dictionary. IEEE Trans Biomed Eng 2015; 61:2724-32. [PMID: 25330152 DOI: 10.1109/tbme.2014.2326921] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Atomic decomposition (AD) can be used to efficiently decompose an arbitrary signal. In this paper, we present a method to detect neonatal electroencephalogram (EEG) seizure based on AD via orthogonal matching pursuit using a novel, application-specific, dictionary. The dictionary consists of pseudoperiodic Duffing oscillator atoms which are designed to be coherent with the seizure epochs. The relative structural complexity (a measure of the rate of convergence of AD) is used as the sole feature for seizure detection. The proposed feature was tested on a large clinical dataset of 826 h of EEG data from 18 full-term newborns with 1389 seizures. The seizure detection system using the proposed dictionary was able to achieve a median receiver operator characteristic area of 0.91 (IQR 0.87-0.95) across 18 neonates.
Collapse
|
7
|
Temko A, Marnane W, Boylan G, Lightbody G. Clinical implementation of a neonatal seizure detection algorithm. DECISION SUPPORT SYSTEMS 2015; 70:86-96. [PMID: 25892834 PMCID: PMC4394138 DOI: 10.1016/j.dss.2014.12.006] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/23/2014] [Revised: 12/09/2014] [Accepted: 12/20/2014] [Indexed: 06/04/2023]
Abstract
Technologies for automated detection of neonatal seizures are gradually moving towards cot-side implementation. The aim of this paper is to present different ways to visualize the output of a neonatal seizure detection system and analyse their influence on performance in a clinical environment. Three different ways to visualize the detector output are considered: a binary output, a probabilistic trace, and a spatio-temporal colormap of seizure observability. As an alternative to visual aids, audified neonatal EEG is also considered. Additionally, a survey on the usefulness and accuracy of the presented methods has been performed among clinical personnel. The main advantages and disadvantages of the presented methods are discussed. The connection between information visualization and different methods to compute conventional metrics is established. The results of the visualization methods along with the system validation results indicate that the developed neonatal seizure detector with its current level of performance would unambiguously be of benefit to clinicians as a decision support system. The results of the survey suggest that a suitable way to visualize the output of neonatal seizure detection systems in a clinical environment is a combination of a binary output and a probabilistic trace. The main healthcare benefits of the tool are outlined. The decision support system with the chosen visualization interface is currently undergoing pre-market European multi-centre clinical investigation to support its regulatory approval and clinical adoption.
Collapse
Affiliation(s)
- Andriy Temko
- Neonatal Brain Research Group, INFANT Research Centre, Dept. Electrical and Electronic Engineering, University College Cork, Cork, Ireland
| | - William Marnane
- Neonatal Brain Research Group, INFANT Research Centre, Dept. Electrical and Electronic Engineering, University College Cork, Cork, Ireland
| | - Geraldine Boylan
- Neonatal Brain Research Group, INFANT Research Centre, Dept. Pediatrics and Child Health, University College Cork, Cork, Ireland
| | - Gordon Lightbody
- Neonatal Brain Research Group, INFANT Research Centre, Dept. Electrical and Electronic Engineering, University College Cork, Cork, Ireland
| |
Collapse
|
8
|
Temko A, Sarkar A, Lightbody G. Detection of seizures in intracranial EEG: UPenn and Mayo Clinic's Seizure Detection Challenge. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2015; 2015:6582-6585. [PMID: 26737801 DOI: 10.1109/embc.2015.7319901] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
A system for detection of seizures in intracranial EEG is presented that is based on a combination of generative, discriminative and hybrid approaches. We present a methodology to effectively benefit from the advantages each classifier offers. In particular, Gaussian mixture models, Support Vector Machines, hybrid likelihood ratio and Gaussian supervector approaches are developed and combined for the task. This system participated in the UPenn and Mayo Clinic's Seizure Detection Challenge, ranking in the top 5 of over 200 participants. The drawbacks of the proposed method with respect to the winning solutions are critically assessed.
Collapse
|
9
|
Abstract
Seizures occur in approximately 1 to 5 per 1000 live births and are among the most common neurologic conditions managed by a neonatal neurocritical care service. There are several, age-specific factors that are particular to the developing brain, which influence excitability and seizure generation, response to medications, and impact of seizures on brain structure and function. Neonatal seizures are often associated with serious underlying brain injury such as hypoxia-ischemia, stroke, or hemorrhage. Conventional, prolonged, continuous video electroencephalogram is the gold standard for detecting seizures, whereas amplitude-integrated EEG is a convenient and useful bedside tool.
Collapse
Affiliation(s)
- Hannah C. Glass
- Departments of Neurology and Pediatrics University of California, San Francisco, United States of America
| |
Collapse
|
10
|
|
11
|
Abstract
Neonatal seizures are a neurological emergency and prompt treatment is required. Seizure burden in neonates can be very high, status epilepticus a frequent occurrence, and the majority of seizures do not have any clinical correlate. Detection of neonatal seizures is only possible with continuous electroencephalogram (EEG) monitoring. EEG interpretation requires special expertise that is not available in most neonatal intensive care units (NICUs). As a result, a simplified method of EEG recording incorporating an easy-to-interpret compressed trend of the EEG output (amplitude integrated EEG) from one of the EEG output from one or two channels has emerged as a popular way to monitor neurological function in the NICU. This is not without limitations; short duration and low amplitude seizures can be missed, artefacts are problematic and may mimic seizure-like activity and only a restricted area of the brain is monitored. Continuous multichannel EEG is the gold standard for detecting seizures and monitoring response to therapy but expert interpretation of the EEG output is generally not available. Some centres have set up remote access for neurophysiologists to the cot-side EEG, but reliable interpretation is wholly dependent on the 24 h availability of experts, an expensive solution. A more practical solution for the NICU without such expertise is an automated seizure detection system. This review outlines the current state of the art regarding cot-side monitoring of neonatal seizures in the NICU.
Collapse
Affiliation(s)
- Geraldine B Boylan
- Neonatal Brain Research Group, Department of Paediatrics & Child Health, University College Cork, Ireland.
| | | | | |
Collapse
|
12
|
TEMKO ANDRIY, BOYLAN GERALDINE, MARNANE WILLIAM, LIGHTBODY GORDON. Robust neonatal EEG seizure detection through adaptive background modeling. Int J Neural Syst 2013; 23:1350018. [PMID: 23746291 PMCID: PMC3957205 DOI: 10.1142/s0129065713500184] [Citation(s) in RCA: 50] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Adaptive probabilistic modeling of the EEG background is proposed for seizure detection in neonates with hypoxic ischemic encephalopathy. The decision is made based on the temporal derivative of the seizure probability with respect to the adaptively modeled level of background activity. The robustness of the system to long duration "seizure-like" artifacts, in particular those due to respiration, is improved. The system was developed using statistical leave-one-patient-out performance assessment, on a large clinical dataset, comprising 38 patients of 1479 h total duration. The developed technique was then validated by a single test on a separate totally unseen randomized prospective dataset of 51 neonates totaling 2540 h of duration. By exploiting the proposed adaptation, the ROC area is increased from 93.4% to 96.1% (41% relative improvement). The number of false detections per hour is decreased from 0.42 to 0.24, while maintaining the correct detection of seizure burden at 70%. These results on the unseen data were predicted from the rigorous leave-one-patient-out validation and confirm the validity of our algorithm development process.
Collapse
Affiliation(s)
- ANDRIY TEMKO
- Neonatal Brain Research Group, Department of Electrical and Electronic Engineering, University College Cork, Ireland
| | - GERALDINE BOYLAN
- Neonatal Brain Research Group, Department of Paediatrics and Child Health, University College Cork, Ireland
| | - WILLIAM MARNANE
- Neonatal Brain Research Group, Department of Electrical and Electronic Engineering, University College Cork, Ireland
| | - GORDON LIGHTBODY
- Neonatal Brain Research Group, Department of Electrical and Electronic Engineering, University College Cork, Ireland
| |
Collapse
|
13
|
|