1
|
Hopstock KS, Perraud V, Dalton AB, Barletta B, Meinardi S, Weltman RM, Mirkhanian MA, Rakosi KJ, Blake DR, Edwards RD, Nizkorodov SA. Chemical Analysis of Exhaled Vape Emissions: Unraveling the Complexities of Humectant Fragmentation in a Human Trial Study. Chem Res Toxicol 2024. [PMID: 38769630 DOI: 10.1021/acs.chemrestox.4c00088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/22/2024]
Abstract
Electronic cigarette smoking (or vaping) is on the rise, presenting questions about the effects of secondhand exposure. The chemical composition of vape emissions was examined in the exhaled breath of eight human volunteers with the high chemical specificity of complementary online and offline techniques. Our study is the first to take multiple exhaled puff measurements from human participants and compare volatile organic compound (VOC) concentrations between two commonly used methods, proton-transfer-reaction time-of-flight mass spectrometry (PTR-ToF-MS) and gas chromatography (GC). Five flavor profile groups were selected for this study, but flavor compounds were not observed as the main contributors to the PTR-ToF-MS signal. Instead, the PTR-ToF-MS mass spectra were overwhelmed by e-liquid thermal decomposition and fragmentation products, which masked other observations regarding flavorings and other potentially toxic species associated with secondhand vape exposure. Compared to the PTR-ToF-MS, GC measurements reported significantly different VOC concentrations, usually below those from PTR-ToF-MS. Consequently, PTR-ToF-MS mass spectra should be interpreted with caution when reporting quantitative results in vaping studies, such as doses of inhaled VOCs. Nevertheless, the online PTR-ToF-MS analysis can provide valuable qualitative information by comparing relative VOCs in back-to-back trials. For example, by comparing the mass spectra of exhaled air with those of direct puffs, we can conclude that harmful VOCs present in the vape emissions are largely absorbed by the participants, including large fractions of nicotine.
Collapse
Affiliation(s)
- Katherine S Hopstock
- Department of Chemistry, University of California, Irvine, California 92697, United States
| | - Véronique Perraud
- Department of Chemistry, University of California, Irvine, California 92697, United States
| | - Avery B Dalton
- Department of Chemistry, University of California, Irvine, California 92697, United States
| | - Barbara Barletta
- Department of Chemistry, University of California, Irvine, California 92697, United States
| | - Simone Meinardi
- Department of Chemistry, University of California, Irvine, California 92697, United States
| | - Robert M Weltman
- Program in Public Health, University of California, Irvine, California 92697, United States
| | - Megan A Mirkhanian
- Program in Public Health, University of California, Irvine, California 92697, United States
| | - Krisztina J Rakosi
- Department of Chemistry, University of California, Irvine, California 92697, United States
| | - Donald R Blake
- Department of Chemistry, University of California, Irvine, California 92697, United States
| | - Rufus D Edwards
- Program in Public Health, University of California, Irvine, California 92697, United States
| | - Sergey A Nizkorodov
- Department of Chemistry, University of California, Irvine, California 92697, United States
| |
Collapse
|
2
|
Vivaldi FM, Reale S, Ghimenti S, Biagini D, Lenzi A, Lomonaco T, Di Francesco F. A low-cost internal standard loader for solid-phase sorbing tools. J Breath Res 2023; 17:046008. [PMID: 37567168 DOI: 10.1088/1752-7163/acef4b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2023] [Accepted: 08/11/2023] [Indexed: 08/13/2023]
Abstract
Solid-phase sorption is widely used for the analysis of gaseous specimens as it allows at the same time to preconcentrate target analytes and store samples for relatively long periods. The addition of internal standards (ISs) in the analytical workflow can greatly reduce the variability of the analyses and improve the reliability of the protocols. In this work, we describe the development and testing of a portable system for the reliable production of gaseous mixture of8D-Toluene in a 1L Silonite canister as well as its reproducible loading into solid-phase sorbing tools as ISs. The portable system was tested using needle trap microextraction, solid-phase extraction, and thin-film microextraction techniques commonly employed for the analysis of gaseous samples. Even though our specific interest is in breath analysis, the system can also be used for the collection of any kind of gaseous specimen. A microcontroller allows the fine control of the sampling flow by a digital mass flow controller. Flow rate and sample volume could be set either through a rotary encoder mounted onto the control board or through a dedicated android app. The variability of the airflow is in the range 5-200 ml min-1and it is lower than 1%, whereas the variability of the IS (8D-Toluene) concentration dispensed over time by the loader measured by selected-ion flow-tube mass spectrometry (MS) is <3%. This combination resulted in intra- and inter-day precision of the amount loaded in the sorbent tools lower than 15%. No carry-over was detected in the loader after the delivery of the8D-Toluene measured by gas chromatography-MS. The8D-Toluene concentration in the canister was stable for up to three weeks at room temperature.
Collapse
Affiliation(s)
- F M Vivaldi
- Department of Chemistry and Industrial Chemistry, University of Pisa, via Giuseppe Moruzzi 13, 56124 Pisa, Italy
| | - S Reale
- Department of Chemistry and Industrial Chemistry, University of Pisa, via Giuseppe Moruzzi 13, 56124 Pisa, Italy
| | - S Ghimenti
- Department of Chemistry and Industrial Chemistry, University of Pisa, via Giuseppe Moruzzi 13, 56124 Pisa, Italy
| | - D Biagini
- Department of Chemistry and Industrial Chemistry, University of Pisa, via Giuseppe Moruzzi 13, 56124 Pisa, Italy
| | - A Lenzi
- Department of Chemistry and Industrial Chemistry, University of Pisa, via Giuseppe Moruzzi 13, 56124 Pisa, Italy
| | - T Lomonaco
- Department of Chemistry and Industrial Chemistry, University of Pisa, via Giuseppe Moruzzi 13, 56124 Pisa, Italy
| | - F Di Francesco
- Department of Chemistry and Industrial Chemistry, University of Pisa, via Giuseppe Moruzzi 13, 56124 Pisa, Italy
| |
Collapse
|
3
|
Paleczek A, Grochala D, Rydosz A. Artificial Breath Classification Using XGBoost Algorithm for Diabetes Detection. SENSORS 2021; 21:s21124187. [PMID: 34207196 PMCID: PMC8234852 DOI: 10.3390/s21124187] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/06/2021] [Revised: 06/13/2021] [Accepted: 06/17/2021] [Indexed: 11/16/2022]
Abstract
Exhaled breath analysis has become more and more popular as a supplementary tool for medical diagnosis. However, the number of variables that have to be taken into account forces researchers to develop novel algorithms for proper data interpretation. This paper presents a system for analyzing exhaled air with the use of various sensors. Breath simulations with acetone as a diabetes biomarker were performed using the proposed e-nose system. The XGBoost algorithm for diabetes detection based on artificial breath analysis is presented. The results have shown that the designed system based on the XGBoost algorithm is highly selective for acetone, even at low concentrations. Moreover, in comparison with other commonly used algorithms, it was shown that XGBoost exhibits the highest performance and recall.
Collapse
|
4
|
Slingers G, Goossens R, Janssens H, Spruyt M, Goelen E, Vanden EM, Raes M, Koppen G. Real-time selected ion flow tube mass spectrometry to assess short- and long-term variability in oral and nasal breath. J Breath Res 2020; 14:036006. [PMID: 32422613 DOI: 10.1088/1752-7163/ab9423] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Breath-based non-invasive diagnostics have the potential to provide valuable information about a person's health status. However, they are not yet widely used in clinical practice due to multiple factors causing variability and the lack of standardized procedures. This study focuses on the comparison of oral and nasal breathing, and on the variability of volatile metabolites over the short and long term. Selected ion flow tube mass spectrometry (SIFT-MS) was used for online analysis of selected volatile metabolites in oral and nasal breath of 10 healthy individuals five times in one day (short-term) and six times spread over three weeks (long-term), resulting in nearly 100 breath samplings. Intra-class correlation coefficients (ICCs) were used to assess short- and long-term biological variability. Additionally, the composition of ambient air was analyzed at different samplings. The selected volatiles common in exhaled breath were propanol, 2,3-butanedione, acetaldehyde, acetone, ammonia, dimethyl sulfide, isoprene, pentane, and propanal. Additionally, environmental compounds benzene and styrene were analyzed as well. Volatile metabolite concentrations in ambient air were not correlated with those in exhaled breath and were significantly lower than in breath samples. All volatiles showed significant correlation between oral and nasal breath. Five were significantly higher in oral breath compared to nasal breath, while for acetone, propanal, dimethyl sulfide, and ammonia, concentrations were similar in both matrices. Variability depended on the volatile metabolite. Most physiologically relevant volatiles (acetone, isoprene, propanol, acetaldehyde) showed good to very good biological reproducibility (ICC > 0.61) mainly in oral breath and over a short-term period of one day. Both breathing routes showed relatively similar patterns; however, bigger differences were expected. Therefore, since sampling from the mouth is practically more easy, the latter might be preferred.
Collapse
Affiliation(s)
- G Slingers
- Hasselt University, Faculty of Medicine and Life Sciences, LCRC, Agoralaan 3590, Diepenbeek, Belgium. Flemish Institute for Technological Research, Unit Health, Industriezone Vlasmeer 2400, Mol, Belgium. Paediatrics, Jessa Hospital, Hasselt, Stadsomvaart 3500, Belgium
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Brůhová Michalčíková R, Dryahina K, Smith D, Španěl P. Volatile compounds released by Nalophan; implications for selected ion flow tube mass spectrometry and other chemical ionisation mass spectrometry analytical methods. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8602. [PMID: 31756780 DOI: 10.1002/rcm.8602] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 09/12/2019] [Accepted: 09/13/2019] [Indexed: 06/10/2023]
Abstract
UNLABELLED Nalophan bags are commonly used to collect breath samples for volatile metabolite analysis. Volatile organic compounds (VOCs) released from the polymer can, however, be mistaken as breath metabolites when analyses are performed by selected ion flow tube mass spectrometry, SIFT-MS, or techniques that depend on a proper understanding of ion chemistry. METHODS Three analytical techniques were used to analyse the VOCs released into the nitrogen used to expand Nalophan bags, viz. gas chromatography/mass spectrometry (GC/MS), secondary electrospray ionization mass spectrometry (SESI-MS) and selected ion flow tube mass spectrometry (SIFT-MS). The most significant VOCs were identified and quantified by SIFT-MS as a function of storage time, temperature and humidity. RESULTS The consistent results obtained by these three analytical methods identify 1,2-ethanediol (ethylene glycol) and 2-methyl-1,3-dioxolane as the major VOCs released by the Nalophan. Their concentrations are enhanced by increasing the bag storage temperature and time, reaching 170 parts-per-billion by volume (ppbv) for ethylene glycol and 34 ppbv for 2-methyl-1,3-dioxolane in humid nitrogen (absolute humidity of 5%) contained in an 8-L Nalophan bag stored at 37°C for 160 min. CONCLUSIONS Using H3 O+ reagent ions for SIFT-MS and SESI-MS analyses, the following analyte ions (m/z values) are affected by the Nalophan impurities: 45, 63, 81, 89 and 99, which can compromise analyses of acetaldehyde, ethylene glycol, monoterpenes, acetoin, butyric acid, hexanal and heptane.
Collapse
Affiliation(s)
- Regina Brůhová Michalčíková
- J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova, Czech Republic
- Department of Physical and Macromolecular Chemistry, Faculty of Science, Charles University, Albertov, Czech Republic
| | - Kseniya Dryahina
- J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova, Czech Republic
| | - David Smith
- J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova, Czech Republic
| | - Patrik Španěl
- J. Heyrovský Institute of Physical Chemistry, Academy of Sciences of the Czech Republic, Dolejškova, Czech Republic
| |
Collapse
|
6
|
Li B, Zou X, Wang H, Lu Y, Shen C, Chu Y. Standardization study of expiratory conditions for on-line breath testing by proton transfer reaction mass spectrometry. Anal Biochem 2019; 581:113344. [DOI: 10.1016/j.ab.2019.113344] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2019] [Revised: 06/19/2019] [Accepted: 06/19/2019] [Indexed: 12/14/2022]
|
7
|
Germanese D, Colantonio S, D'Acunto M, Romagnoli V, Salvati A, Brunetto M. An E-Nose for the Monitoring of Severe Liver Impairment: A Preliminary Study. SENSORS 2019; 19:s19173656. [PMID: 31443499 PMCID: PMC6749560 DOI: 10.3390/s19173656] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 07/25/2019] [Accepted: 08/09/2019] [Indexed: 11/16/2022]
Abstract
Biologically inspired to mammalian olfactory system, electronic noses became popular during the last three decades. In literature, as well as in daily practice, a wide range of applications are reported. Nevertheless, the most pioneering one has been (and still is) the assessment of the human breath composition. In this study, we used a prototype of electronic nose, called Wize Sniffer (WS) and based it on an array of semiconductor gas sensor, to detect ammonia in the breath of patients suffering from severe liver impairment. In the setting of severely impaired liver, toxic substances, such as ammonia, accumulate in the systemic circulation and in the brain. This may result in Hepatic Encephalopathy (HE), a spectrum of neuro-psychiatric abnormalities which include changes in cognitive functions, consciousness, and behaviour. HE can be detected only by specific but time-consuming and burdensome examinations, such as blood ammonia levels assessment and neuro-psychological tests. In the presented proof-of-concept study, we aimed at investigating the possibility of discriminating the severity degree of liver impairment on the basis of the detected breath ammonia, in view of the detection of HE at its early stage.
Collapse
Affiliation(s)
- Danila Germanese
- Institute of Information Science and Technology (ISTI), National Research Council (CNR), 56127 Pisa, Italy.
| | - Sara Colantonio
- Institute of Information Science and Technology (ISTI), National Research Council (CNR), 56127 Pisa, Italy
| | - Mario D'Acunto
- Institute of Biophysics (IBF), National Research Council (CNR), 56127 Pisa, Italy
| | - Veronica Romagnoli
- Gastroenterology and Hepatology Unit, University Hospital of Pisa, 56127 Pisa, Italy
| | - Antonio Salvati
- Gastroenterology and Hepatology Unit, University Hospital of Pisa, 56127 Pisa, Italy
| | - Maurizia Brunetto
- Gastroenterology and Hepatology Unit, University Hospital of Pisa, 56127 Pisa, Italy
| |
Collapse
|
8
|
Isensee K, Kröger-Lui N, Petrich W. Biomedical applications of mid-infrared quantum cascade lasers - a review. Analyst 2019; 143:5888-5911. [PMID: 30444222 DOI: 10.1039/c8an01306c] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Mid-infrared spectroscopy has been applied to research in biology and medicine for more than 20 years and conceivable applications have been identified. More recently, these applications have been shown to benefit from the use of quantum cascade lasers due to their specific properties, namely high spectral power density, small beam parameter product, narrow emission spectrum and, if needed, tuning capabilities. This review provides an overview of the achievements and illustrates some applications which benefit from the key characteristics of quantum cascade laser-based mid-infrared spectroscopy using examples such as breath analysis, the investigation of serum, non-invasive glucose monitoring in bulk tissue and the combination of spectroscopy and microscopy of tissue thin sections for rapid histopathology.
Collapse
Affiliation(s)
- Katharina Isensee
- Kirchhoff-Institute for Physics, Heidelberg University, INF 277, 69120 Heidelberg, Germany.
| | | | | |
Collapse
|
9
|
Hanna GB, Boshier PR, Markar SR, Romano A. Accuracy and Methodologic Challenges of Volatile Organic Compound-Based Exhaled Breath Tests for Cancer Diagnosis: A Systematic Review and Meta-analysis. JAMA Oncol 2019; 5:e182815. [PMID: 30128487 PMCID: PMC6439770 DOI: 10.1001/jamaoncol.2018.2815] [Citation(s) in RCA: 119] [Impact Index Per Article: 23.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2018] [Accepted: 05/08/2018] [Indexed: 12/19/2022]
Abstract
Importance The detection and quantification of volatile organic compounds (VOCs) within exhaled breath have evolved gradually for the diagnosis of cancer. The overall diagnostic accuracy of proposed tests remains unknown. Objectives To determine the diagnostic accuracy of VOC breath tests for the detection of cancer and to review sources of methodologic variability. Data Sources An electronic search (title and abstract) was performed using the Embase and MEDLINE databases (January 1, 2000, to May 28, 2017) through the OVID platform. The search terms cancer, neoplasm, malignancy, volatile organic compound, VOC, breath, and exhaled were used in combination with the Boolean operators AND and OR. A separate MEDLINE search that used the search terms breath AND methodology was also performed for studies that reported factors that influenced the concentration of VOCs within exhaled breath in humans. Study Selection The search was limited to human studies published in the English language. Trials that analyzed named endogenous VOCs within exhaled breath to diagnose or assess cancer were included in this review. Data Extraction and Synthesis Systematic review and pooled analysis were conducted in accordance with the recommendations of the Cochrane Library and Meta-analysis of Observational Studies in Epidemiology guidelines. Bivariate meta-analyses were performed to generate pooled point estimates of the hierarchal summary receiver operating characteristic curve of breath VOC analysis. Included studies were assessed according to the Standards for Reporting of Diagnostic Accuracy Studies checklist and Quality Assessment of Diagnostic Accuracy Studies 2 tool. Main Outcomes and Measures The principal outcome measure was pooled diagnostic accuracy of published VOC breath tests for cancer. Results The review identified 63 relevant publications and 3554 patients. All reports constituted phase 1 biomarker studies. Pooled analysis of findings found a mean (SE) area under the receiver operating characteristic analysis curve of 0.94 (0.01), sensitivity of 79% (95% CI, 77%-81%), and specificity of 89% (95% CI, 88%-90%). Factors that may influence variability in test results included breath collection method, patient physiologic condition, test environment, and method of analysis. Conclusions and Relevance The findings of our review suggest that standardization of breath collection methods and masked validation of breath test accuracy for cancer diagnosis is needed among the intended population in multicenter clinical trials. We propose a framework to guide the conduct of future breath tests in cancer studies.
Collapse
Affiliation(s)
- George B. Hanna
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Piers R. Boshier
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Sheraz R. Markar
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| | - Andrea Romano
- Department of Surgery and Cancer, Imperial College London, London, United Kingdom
| |
Collapse
|
10
|
Fasbender L, Yáñez-Serrano AM, Kreuzwieser J, Dubbert D, Werner C. Real-time carbon allocation into biogenic volatile organic compounds (BVOCs) and respiratory carbon dioxide (CO2) traced by PTR-TOF-MS, 13CO2 laser spectroscopy and 13C-pyruvate labelling. PLoS One 2018; 13:e0204398. [PMID: 30252899 PMCID: PMC6155514 DOI: 10.1371/journal.pone.0204398] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Accepted: 09/07/2018] [Indexed: 01/09/2023] Open
Abstract
Our understanding of biogenic volatile organic compound (BVOC) emissions improved substantially during the last years. Nevertheless, there are still large uncertainties of processes controlling plant carbon investment into BVOCs, of some biosynthetic pathways and their linkage to CO2 decarboxylation at central metabolic branching points. To shed more light on carbon partitioning during BVOC biosynthesis, we used an innovative approach combining δ13CO2 laser spectroscopy, high-sensitivity proton-transfer-reaction time-of-flight mass spectrometry and a multiple branch enclosure system in combination with position-specific 13C-metabolite labelling. Feeding experiments with position-specific 13C-labelled pyruvate, a central metabolite of BVOC synthesis, enabled online detection of carbon partitioning into 13C-BVOCs and respiratory 13CO2. Measurements of trace gas emissions of the Mediterranean shrub Halimium halimifolium revealed a broad range of emitted BVOCs. In general, [2-13C]-PYR was rapidly incorporated into emitted acetic acid, methyl acetate, toluene, cresol, trimethylbenzene, ethylphenol, monoterpenes and sesquiterpenes, indicating de novo BVOC biosynthesis of these compounds. In contrast, [1-13C]-pyruvate labelling substantially increased 13CO2 emissions in the light indicating C1-decarboxylation. Similar labelling patterns of methyl acetate and acetic acid suggested tightly connected biosynthetic pathways and, furthermore, there were hints of possible biosynthesis of benzenoids via the MEP-pathway. Overall, substantial CO2 emission from metabolic branching points during de novo BVOC biosynthesis indicated that decarboxylation of [1-13C]-pyruvate, as a non-mitochondrial source of CO2, seems to contribute considerably to daytime CO2 release from leaves. Our approach, combining synchronised BVOC and CO2 measurements in combination with position-specific labelling opens the door for real-time analysis tracing metabolic pathways and carbon turnover under different environmental conditions, which may enhance our understanding of regulatory mechanisms in plant carbon metabolism and BVOC biosynthesis.
Collapse
Affiliation(s)
- Lukas Fasbender
- Ecosystem Physiology, Institute of Forest Sciences, Faculty of Environment and Natural Resources, Albert-Ludwigs-University Freiburg, Freiburg, Germany
| | - Ana Maria Yáñez-Serrano
- Ecosystem Physiology, Institute of Forest Sciences, Faculty of Environment and Natural Resources, Albert-Ludwigs-University Freiburg, Freiburg, Germany
| | - Jürgen Kreuzwieser
- Ecosystem Physiology, Institute of Forest Sciences, Faculty of Environment and Natural Resources, Albert-Ludwigs-University Freiburg, Freiburg, Germany
| | - David Dubbert
- Ecosystem Physiology, Institute of Forest Sciences, Faculty of Environment and Natural Resources, Albert-Ludwigs-University Freiburg, Freiburg, Germany
| | - Christiane Werner
- Ecosystem Physiology, Institute of Forest Sciences, Faculty of Environment and Natural Resources, Albert-Ludwigs-University Freiburg, Freiburg, Germany
| |
Collapse
|
11
|
Chappuis TH, Pham Ho BA, Ceillier M, Ricoul F, Alessio M, Beche JF, Corne C, Besson G, Vial J, Thiébaut D, Bourlon B. Miniaturization of breath sampling with silicon chip: application to volatile tobacco markers tracking. J Breath Res 2018; 12:046011. [PMID: 30008462 DOI: 10.1088/1752-7163/aad384] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
This work presents the performances of silicon micro-preconcentrators chips for breath sampling. The silicon chips were coupled to a handheld battery powered system for breath sampling and direct injection in a laboratory gas chromatography mass spectrometry system through thermal desorption (TD). Performances of micro-preconcentrators were first compared to commercial TD for benzene trapping. Similar chromatographic peaks after gas chromatographic separation were observed while the volume of sample needed was reduced by a factor of 5. Repeatability and day to day variability of the micro-preconcentrators were then studied for a 500 ppb synthetic model mixture injected three times a day four days in a row: 8% and 12% were measured respectively. Micro-preconcentrator to micro-preconcentrator variability was not significant compared to day to day variability. In addition, micro-preconcentrators were tested for breath samples collected in Tedlar® bags. Three analyses of the same breath sample displayed relative standard deviations values below 16% for eight of the ten most intense peaks. Finally, the performances of micro-preconcentrators for breath sampling on a single expiration were illustrated with the example of volatile tobacco markers tracking. The signals of three smoking markers in breath, benzene, 2,5-dimethylfuran, and toluene were studied. Concentrations of benzene and toluene were found to be 10 to 100 higher in the breath of smokers. 2,5-dimethylfuran was only found in the breath of smokers. The elimination kinetics of the markers were followed as well during 4 h: a fast decrease of the signal of the three markers in breath was observed 20 min after smoking in good agreement with what is described in the literature. Those results demonstrate the efficiency of silicon chips for breath sampling, compared to the state of the art techniques. Thanks to miniaturization and lower sample volumes needed, micro-preconcentrators could be in the future a key technology towards portable breath sampling and analysis.
Collapse
Affiliation(s)
- Thomas Hector Chappuis
- Univ. Grenoble Alpes, CEA, LETI, MINATEC Campus, F-38000 Grenoble, France. UMR 8231 CBI, LSABM, ESPCI Paris-CNRS, PSL Institute, Paris, France
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Casas-Ferreira AM, Nogal-Sánchez MD, Pérez-Pavón JL, Moreno-Cordero B. Non-separative mass spectrometry methods for non-invasive medical diagnostics based on volatile organic compounds: A review. Anal Chim Acta 2018; 1045:10-22. [PMID: 30454564 DOI: 10.1016/j.aca.2018.07.005] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2018] [Revised: 05/16/2018] [Accepted: 07/02/2018] [Indexed: 12/18/2022]
Abstract
In this review, an assessment of non-separative methods based on mass spectrometry used to analyse volatile organic compounds in the field of bioanalysis is performed. The use of non-separative methods based on mass spectrometry has been established as an attractive option for analysing compounds. These instrumental configurations are suitable for biomedical applications because of their versatility, rapid output of results, and the wide range of volatile organic compounds that can be determined. Here, techniques such as headspace sampling coupled to mass spectrometry, membrane introduction mass spectrometry, selected ion flow tube mass spectrometry, proton transfer reaction mass spectrometry, secondary electrospray ionization mass spectrometry and ion mobility mass spectrometry, are evaluated. Samples involving non-invasive methods of collection, such as urine, saliva, breath and sweat, are mainly considered. To the best of our knowledge, a comprehensive review of all the non-separative instrumental configurations applied to the analysis of gaseous samples from all matrices non-invasively collected has not yet been carried out. The assessment of non-separative techniques for the analysis of these type of samples can be considered a key issue for future clinical applications, as they allow real-time sample analysis, without patient suffering. Any contribution to the early diagnosis of disease can be considered a priority for the scientific community. Therefore, the identification and determination of volatile organic compounds related to particular diseases has become an important field or research.
Collapse
Affiliation(s)
- Ana María Casas-Ferreira
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain
| | - Miguel Del Nogal-Sánchez
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain.
| | - José Luis Pérez-Pavón
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain
| | - Bernardo Moreno-Cordero
- Departamento de Química Analítica, Nutrición y Bromatología Facultad de Ciencias Químicas, Universidad de Salamanca, 37008 Salamanca, Spain
| |
Collapse
|
13
|
Recent analytical approaches to detect exhaled breath ammonia with special reference to renal patients. Anal Bioanal Chem 2016; 409:21-31. [PMID: 27595582 DOI: 10.1007/s00216-016-9903-3] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2016] [Revised: 07/10/2016] [Accepted: 08/24/2016] [Indexed: 12/15/2022]
Abstract
The ammonia odor from the exhaled breath of renal patients is associated with high levels of blood urea nitrogen. Typically, in the liver, ammonia and ammonium ions are converted into urea through the urea cycle. In the case of renal dysfunction, urea is unable to be removed and that causes a buildup of excessive ammonia. As small molecules, ammonia and ammonium ions can be forced into the blood-lung barrier and occur in exhaled breath. Therefore, people with renal failure have an ammonia (fishy) odor in their exhaled breath. Thus, exhaled breath ammonia can be a potential biomarker for monitoring renal diseases during hemodialyis. In this review, we have summarized the source of ammonia in the breath of end-stage renal disease patient, cause of renal disorders, exhaled breath condensate, and breath sampling. Further, various biosensor approaches to detect exhaled ammonia from renal patients and other ammonia systems are also discussed. We conclude with future perspectives, namely colorimetric-based real-time breathing diagnosis of renal failure, which might be useful for prospective studies.
Collapse
|
14
|
Ghimenti S, Lomonaco T, Bellagambi FG, Tabucchi S, Onor M, Trivella MG, Ceccarini A, Fuoco R, Di Francesco F. Comparison of sampling bags for the analysis of volatile organic compounds in breath. J Breath Res 2015; 9:047110. [DOI: 10.1088/1752-7155/9/4/047110] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
15
|
|
16
|
Alonso M, Sanchez JM. Analytical challenges in breath analysis and its application to exposure monitoring. Trends Analyt Chem 2013. [DOI: 10.1016/j.trac.2012.11.011] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
17
|
White IR, Willis KA, Whyte C, Cordell R, Blake RS, Wardlaw AJ, Rao S, Grigg J, Ellis AM, Monks PS. Real-time multi-marker measurement of organic compounds in human breath: towards fingerprinting breath. J Breath Res 2013; 7:017112. [DOI: 10.1088/1752-7155/7/1/017112] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
18
|
Cumeras R, Figueras E, Gràcia I, Maddula S, Baumbach JI. What is a good control group? ACTA ACUST UNITED AC 2013. [DOI: 10.1007/s12127-012-0116-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
19
|
Influence of operational background emissions on breath analysis using MCC/IMS devices. ACTA ACUST UNITED AC 2012. [DOI: 10.1007/s12127-012-0094-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
20
|
|
21
|
Schmidt FM, Metsälä M, Vaittinen O, Halonen L. Background levels and diurnal variations of hydrogen cyanide in breath and emitted from skin. J Breath Res 2011; 5:046004. [PMID: 21808098 DOI: 10.1088/1752-7155/5/4/046004] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
The hydrogen cyanide (HCN) concentration in exhaled human breath and skin gas samples collected with different sampling techniques was measured using near-infrared cavity ring-down spectroscopy. The median baseline HCN concentrations in samples provided by 19 healthy volunteers 2-4 h after the last meal depended on the employed sampling technique: 6.5 parts per billion by volume (ppbv) in mixed (dead space and end-tidal) mouth-exhaled breath collected to a gas sampling bag, 3.9 ppbv in end-tidal mouth-exhaled breath, 1.3 ppbv in end-tidal nose-exhaled breath, 1.0 ppbv in unwashed skin and 0.6 ppbv in washed skin samples. Diurnal measurements showed that elevated HCN levels are to be expected in mouth-exhaled breath samples after food and drink intake, which suggests HCN generation in the oral cavity. The HCN concentrations in end-tidal nose-exhaled breath and skin gas samples were correlated, and it is concluded that these concentrations best reflect systemic HCN levels.
Collapse
Affiliation(s)
- F M Schmidt
- Laboratory of Physical Chemistry, Department of Chemistry, PO Box 55 (A.I. Virtasen aukio 1), FIN-00014 University of Helsinki, Finland
| | | | | | | |
Collapse
|
22
|
Thekedar B, Oeh U, Szymczak W, Hoeschen C, Paretzke HG. Influences of mixed expiratory sampling parameters on exhaled volatile organic compound concentrations. J Breath Res 2010; 5:016001. [DOI: 10.1088/1752-7155/5/1/016001] [Citation(s) in RCA: 38] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
23
|
One-year time series of investigations of analytes within human breath using ion mobility spectrometry. ACTA ACUST UNITED AC 2010. [DOI: 10.1007/s12127-010-0052-7] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
24
|
|
25
|
Experimental setup and analytical methods for the non-invasive determination of volatile organic compounds, formaldehyde and NO in exhaled human breath. Anal Chim Acta 2010; 669:53-62. [DOI: 10.1016/j.aca.2010.04.049] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2010] [Revised: 04/18/2010] [Accepted: 04/25/2010] [Indexed: 01/11/2023]
|
26
|
Salthammer T, Mentese S, Marutzky R. Formaldehyde in the indoor environment. Chem Rev 2010; 110:2536-72. [PMID: 20067232 PMCID: PMC2855181 DOI: 10.1021/cr800399g] [Citation(s) in RCA: 612] [Impact Index Per Article: 43.7] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2008] [Indexed: 01/24/2023]
Affiliation(s)
- Tunga Salthammer
- Fraunhofer Wilhelm-Klauditz-Institut (WKI), Department of Material Analysis and Indoor Chemistry, 38108 Braunschweig, Germany.
| | | | | |
Collapse
|