• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4628136)   Today's Articles (4200)   Subscriber (49621)
For: Reynoso FJ, Tailor R, Wang CKC, Cho SH. Comparison of filtered x-ray spectra and depth doses derived from a hybrid Monte Carlo model of an orthovoltage x-ray unit with experimental measurements. Biomed Phys Eng Express 2016. [DOI: 10.1088/2057-1976/2/4/045011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Number Cited by Other Article(s)
1
Simiele EA, Breitkreutz DY, Capaldi DPI, Liu W, Bush KK, Skinner LB. Precision radiotherapy using monochromatic inverse Compton x-ray sources. Med Phys 2020;48:366-375. [PMID: 33107049 DOI: 10.1002/mp.14552] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2020] [Revised: 09/28/2020] [Accepted: 10/02/2020] [Indexed: 11/10/2022]  Open
2
Manohar N, Reynoso F, Jayarathna S, Moktan H, Ahmed MF, Diagaradjane P, Krishnan S, Cho SH. High-sensitivity imaging and quantification of intratumoral distributions of gold nanoparticles using a benchtop x-ray fluorescence imaging system. OPTICS LETTERS 2019;44:5314-5317. [PMID: 31674996 PMCID: PMC7041486 DOI: 10.1364/ol.44.005314] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Accepted: 09/24/2019] [Indexed: 06/10/2023]
3
Manohar N, Reynoso FJ, Cho SH. Technical Note: A benchtop cone-beam x-ray fluorescence computed tomography (XFCT) system with a high-power x-ray source and transmission CT imaging capability. Med Phys 2018;45:4652-4659. [PMID: 30125950 DOI: 10.1002/mp.13138] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2018] [Revised: 07/22/2018] [Accepted: 08/07/2018] [Indexed: 11/11/2022]  Open
4
Radiosensitization of Prostate Cancers In Vitro and In Vivo to Erbium-filtered Orthovoltage X-rays Using Actively Targeted Gold Nanoparticles. Sci Rep 2017;7:18044. [PMID: 29273727 PMCID: PMC5741750 DOI: 10.1038/s41598-017-18304-y] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Accepted: 12/07/2017] [Indexed: 01/04/2023]  Open
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA