1
|
Moreno-Paz M, dos Santos Severino RS, Sánchez-García L, Manchado JM, García-Villadangos M, Aguirre J, Fernández-Martínez MA, Carrizo D, Kobayashi L, Dave A, Warren-Rhodes K, Davila A, Stoker CR, Glass B, Parro V. Life Detection and Microbial Biomarker Profiling with Signs of Life Detector-Life Detector Chip During a Mars Drilling Simulation Campaign in the Hyperarid Core of the Atacama Desert. ASTROBIOLOGY 2023; 23:1259-1283. [PMID: 37930382 PMCID: PMC10825288 DOI: 10.1089/ast.2021.0174] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2021] [Accepted: 07/02/2023] [Indexed: 11/07/2023]
Abstract
The low organic matter content in the hyperarid core of the Atacama Desert, together with abrupt temperature shifts and high ultraviolet radiation at its surface, makes this region one of the best terrestrial analogs of Mars and one of the best scenarios for testing instrumentation devoted to in situ planetary exploration. We have operated remotely and autonomously the SOLID-LDChip (Signs of Life Detector-Life Detector Chip), an antibody microarray-based sensor instrument, as part of a rover payload during the 2019 NASA Atacama Rover Astrobiology Drilling Studies (ARADS) Mars drilling simulation campaign. A robotic arm collected drilled cuttings down to 80 cm depth and loaded SOLID to process and assay them with LDChip for searching for molecular biomarkers. A remote science team received and analyzed telemetry data and LDChip results. The data revealed the presence of microbial markers from Proteobacteria, Acidobacteria, Bacteroidetes, Actinobacteria, Firmicutes, and Cyanobacteria to be relatively more abundant in the middle layer (40-50 cm). In addition, the detection of several proteins from nitrogen metabolism indicates a pivotal role in the system. These findings were corroborated and complemented on "returned samples" to the lab by a comprehensive analysis that included DNA sequencing, metaproteomics, and a metabolic reconstruction of the sampled area. Altogether, the results describe a relatively complex microbial community with members capable of nitrogen fixation and denitrification, sulfur oxidation and reduction, or triggering oxidative stress responses, among other traits. This remote operation demonstrated the high maturity of SOLID-LDChip as a powerful tool for remote in situ life detection for future missions in the Solar System.
Collapse
Affiliation(s)
- Mercedes Moreno-Paz
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
| | - Rita Sofia dos Santos Severino
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
- Departament of Física y Matemáticas y de Automática, University of Alcalá de Henares (UAH), Madrid, Spain
| | - Laura Sánchez-García
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
| | - Juan Manuel Manchado
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
| | | | - Jacobo Aguirre
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
| | - Miguel Angel Fernández-Martínez
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
- Department of Natural Resource Sciences, McGill University, Québec, Canada
| | - Daniel Carrizo
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
| | - Linda Kobayashi
- Space Science Division and Astrobiology Division, NASA Ames Research Center, Moffett Field, California, USA
| | - Arwen Dave
- Space Science Division and Astrobiology Division, NASA Ames Research Center, Moffett Field, California, USA
| | - Kim Warren-Rhodes
- Space Science Division and Astrobiology Division, NASA Ames Research Center, Moffett Field, California, USA
- Carl Sagan Center, SETI Institute, Mountain View, California, USA
| | - Alfonso Davila
- Space Science Division and Astrobiology Division, NASA Ames Research Center, Moffett Field, California, USA
| | - Carol R. Stoker
- Space Science Division and Astrobiology Division, NASA Ames Research Center, Moffett Field, California, USA
| | - Brian Glass
- Space Science Division and Astrobiology Division, NASA Ames Research Center, Moffett Field, California, USA
| | - Víctor Parro
- Department of Molecular Evolution, Centro de Astrobiología (CAB), INTA-CSIC, Madrid, Spain
| |
Collapse
|
2
|
Billi D, Blanco Y, Ianneo A, Moreno-Paz M, Aguirre J, Baqué M, Moeller R, de Vera JP, Parro V. Mars-like UV Flux and Ionizing Radiation Differently Affect Biomarker Detectability in the Desert Cyanobacterium Chroococcidiopsis as Revealed by the Life Detector Chip Antibody Microarray. ASTROBIOLOGY 2022; 22:1199-1209. [PMID: 36194868 DOI: 10.1089/ast.2022.0013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
The effect of a Mars-like UV flux and γ-radiation on the detectability of biomarkers in dried cells of Chroococcidiopsis sp. CCMEE 029 was investigated using a fluorescence sandwich microarray immunoassay. The production of anti-Chroococcidiopsis antibodies allowed the immunoidentification of a reduced, though still detectable, signal in dried cells mixed with phyllosilicatic and sulfatic Mars regolith simulants after exposure to 6.8 × 105 kJ/m2 of a Mars-like UV flux. No signal was detected in dried cells that were not mixed with minerals after 1.4 × 105 kJ/m2. For γ-radiation (60Co), no detectable variations of the fluorescence signal occurred in dried cells exposed to 113 kGy compared to non-irradiated dried cells. Our results suggest that immunoassay-based techniques could be used to detect life tracers eventually present in the martian subsurface in freshly excavated materials only if shielded from solar UV. The high structural integrity of biomarkers irradiated with γ-radiation that mimics a dose accumulated in 13 Myr at 2 m depth from the martian surface has implications for the potential detectability of similar organic molecules/compounds by future life-detection missions such as the ExoMars Rosalind Franklin rover.
Collapse
Affiliation(s)
- Daniela Billi
- University of Rome Tor Vergata, Department of Biology, Rome, Italy
| | - Yolanda Blanco
- Centro de Astrobiología (CAB), CSIC-INTA, Department of Molecular Evolution, Torrejón de Ardoz, Madrid, Spain
| | - Andrea Ianneo
- University of Rome Tor Vergata, Department of Biology, Rome, Italy
| | - Mercedes Moreno-Paz
- Centro de Astrobiología (CAB), CSIC-INTA, Department of Molecular Evolution, Torrejón de Ardoz, Madrid, Spain
| | - Jacobo Aguirre
- Centro de Astrobiología (CAB), CSIC-INTA, Department of Molecular Evolution, Torrejón de Ardoz, Madrid, Spain
| | - Mickael Baqué
- German Aerospace Center (DLR), Institute of Planetary Research, Planetary Laboratories Department, Berlin, Germany
| | - Ralf Moeller
- German Aerospace Center (DLR), Institute of Aerospace Medicine, Radiation Biology Department, Cologne, Germany
| | - Jean-Pierre de Vera
- German Aerospace Center (DLR), Space Operations and Astronaut Training, Microgravity User Support Center, Cologne, Germany
| | - Victor Parro
- Centro de Astrobiología (CAB), CSIC-INTA, Department of Molecular Evolution, Torrejón de Ardoz, Madrid, Spain
| |
Collapse
|
3
|
Jørgensen MM, Sloth JK, Bæk R. Optimization of High-Throughput Multiplexed Phenotyping of Extracellular Vesicles Performed in 96-Well Microtiter Plates. Polymers (Basel) 2021; 13:polym13142368. [PMID: 34301125 PMCID: PMC8309600 DOI: 10.3390/polym13142368] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 07/02/2021] [Accepted: 07/08/2021] [Indexed: 12/25/2022] Open
Abstract
Extracellular vesicles (EVs) are promising biomarkers for several diseases, however, no simple and robust methods exist to characterize EVs in a clinical setting. The EV Array analysis is based on a protein microarray platform, where antibodies are printed onto a solid surface that enables the capture of small EVs (sEVs) by their surface or surface-associated proteins. The EV Array analysis was transferred to an easily handled microtiter plate (MTP) format and a range of optimization experiments were performed within this study. The optimization was performed in a comprehensive analytical setup where the focus was on the selection of additives added to spotting-, blocking-, and incubation buffers as well as the storage of printed antibody arrays under different temperatures from one day to 12 weeks. After ending the analysis, the stability of the fluorescent signal was investigated at different storage conditions for up to eight weeks. The various parameters and conditions tested within this study were shown to have a high influence on each other. The reactivity of the spots was found to be preserved for up to 12 weeks when stored at room temperature and using blocking procedure IV in combination with trehalose in the spotting buffer. Similar preservation could be obtained using glycerol or sciSPOT D1 in the spotting buffers, but only if stored at 4 °C after blocking procedure I. Conclusively, it was found that immediate scanning of the MTPs after analysis was not critical if stored dried, in the dark, and at room temperature. The findings in this study highlight the necessity of performing optimization experiments when transferring an established analysis to a new technological platform.
Collapse
Affiliation(s)
- Malene Møller Jørgensen
- Department of Clinical Immunology, Aalborg University Hospital, 9000 Aalborg, Denmark; (J.K.S.); (R.B.)
- Department of Clinical Medicine, Aalborg University, 9000 Aalborg, Denmark
- Correspondence:
| | - Jenni Kathrine Sloth
- Department of Clinical Immunology, Aalborg University Hospital, 9000 Aalborg, Denmark; (J.K.S.); (R.B.)
| | - Rikke Bæk
- Department of Clinical Immunology, Aalborg University Hospital, 9000 Aalborg, Denmark; (J.K.S.); (R.B.)
| |
Collapse
|
4
|
Creamer JS, Mora MF, Noell AC, Willis PA. Long-term thermal stability of fluorescent dye used for chiral amino acid analysis on future spaceflight missions. Electrophoresis 2019; 40:3117-3122. [PMID: 31599461 DOI: 10.1002/elps.201900268] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 09/24/2019] [Accepted: 09/25/2019] [Indexed: 11/11/2022]
Abstract
Future spaceflight missions focused on life detection will carry with them new, state-of-the-art instrumentation capable of highly selective and sensitive organic analysis. CE-LIF is an ideal candidate for such a mission due to its high separation efficiency and low LODs. One perceived risk of utilizing this technique on a future mission is the stability of the chemical reagents in the spaceflight environment. Here, we present an investigation of the thermal stability of the fluorescent dye (5-carboxyfluorescein succinimidyl ester) used for amino acid analysis. The dye was stored at 4, 25, and 60°C for 1 month, 6 months, 1 year, and 2 years. When stored at 4°C for 2 years, 25°C for 6 months, or 60°C for 1 month there was no effect on CE-LIF assay performance due to dye degradation. Beyond these time points, while the dye degradation begins to interfere with the analysis, it is still possible to perform the analysis and achieve the majority of amino acid biosignature science goals described in the science definition team report for the potential Europa Lander mission. This work indicates that thermal control of the dye at ≤4°C will be needed during transit on future spaceflight missions to maintain dye stability.
Collapse
Affiliation(s)
- Jessica S Creamer
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| | - Maria F Mora
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| | - Aaron C Noell
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| | - Peter A Willis
- Jet Propulsion Laboratory, California Institute of Technology, Pasadena, California
| |
Collapse
|
5
|
Coussot G, Le Postollec A, Faye C, Baqué M, Vandenabeele-Trambouze O, Incerti S, Vigier F, Chaput D, Cottin H, Przybyla B, Berger T, Dobrijevic M. Photochemistry on the Space Station-Antibody Resistance to Space Conditions after Exposure Outside the International Space Station. ASTROBIOLOGY 2019; 19:1053-1062. [PMID: 30817173 DOI: 10.1089/ast.2018.1907] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Antibody-based analytical instruments are under development to detect signatures of life on planetary bodies. Antibodies are molecular recognition reagents able to detect their target at sub-nanomolar concentrations, with high affinity and specificity. Studying antibody binding performances under space conditions is mandatory to convince space agencies of the adequacy of this promising tool for planetary exploration. To complement previous ground-based experiments on antibody resistance to simulated irradiation, we evaluate in this paper the effects of antibody exposure to real space conditions during the EXPOSE-R2 mission outside the International Space Station. The absorbed dose of ionizing radiation recorded during the 588 days of this mission (220 mGy) corresponded to the absorbed dose expected during a mission to Mars. Moreover, samples faced, at the same time as irradiation, thermal cycles, launch constraints, and long-term storage. A model biochip was used in this study with antibodies in freeze-dried form and under two formats: free or covalently grafted to a solid surface. We found that antibody-binding performances were not significantly affected by cosmic radiation, and more than 40% of the exposed antibody, independent of its format, was still functional during all this experiment. We conclude that antibody-based instruments are well suited for in situ analysis on planetary bodies.
Collapse
Affiliation(s)
- Gaëlle Coussot
- 1Institut des Biomolécules Max Mousseron (IBMM), Université de Montpellier, CNRS, ENSCM, Montpellier, France
| | - Aurélie Le Postollec
- 2Laboratoire d'Astrophysique de Bordeaux (LAB), Université de Bordeaux, CNRS, Pessac, France
| | | | - Mickaël Baqué
- 4German Aerospace Center (DLR), Institute of Planetary Research, Management and Infrastructure, Research Group Astrobiological Laboratories, Berlin, Germany
| | - Odile Vandenabeele-Trambouze
- 5Université de Bretagne Occidentale (UBO), IUEM-UMR 6197, Laboratoire de Microbiologie des Environnements Extrêmes (LMEE), Plouzané, France
| | - Sébastien Incerti
- 6Centre d'Etudes Nucléaires de Bordeaux Gradignan (CENBG), UMR 5797, Université de Bordeaux, Gradignan, France
| | | | - Didier Chaput
- 7Centre National d'Etudes Spatiales, DCT/ME/EM, Toulouse, France
| | - Hervé Cottin
- 8Laboratoire Interuniversitaire des Systèmes Atmosphériques (LISA), UMR 7583, Université Paris Est Créteil et Université Paris Diderot, Institut Pierre Simon Laplace, Créteil, France
| | - Bartos Przybyla
- 9German Aerospace Center, Institute of Aerospace Medicine, Cologne, Germany
| | - Thomas Berger
- 9German Aerospace Center, Institute of Aerospace Medicine, Cologne, Germany
| | - Michel Dobrijevic
- 2Laboratoire d'Astrophysique de Bordeaux (LAB), Université de Bordeaux, CNRS, Pessac, France
| |
Collapse
|
6
|
Coussot G, Le Postollec A, Incerti S, Baqué M, Faye C, Vandenabeele-Trambouze O, Cottin H, Ravelet C, Peyrin E, Fiore E, Vigier F, Caron J, Chaput D, Przybyla B, Berger T, Dobrijevic M. Photochemistry on the Space Station-Aptamer Resistance to Space Conditions: Particles Exposure from Irradiation Facilities and Real Exposure Outside the International Space Station. ASTROBIOLOGY 2019; 19:1063-1074. [PMID: 30817199 DOI: 10.1089/ast.2018.1896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Some microarray-based instruments that use bioaffinity receptors such as antibodies or aptamers are under development to detect signatures of past or present life on planetary bodies. Studying the resistance of such instruments against space constraints and cosmic rays in particular is a prerequisite. We used several ground-based facilities to study the resistance of aptamers to various types of particles (protons, electrons, neutrons, and carbon ions) at different energies and fluences. We also tested the resistance of aptamers during the EXPOSE-R2 mission outside the International Space Station (ISS). The accumulated dose measured after the 588 days of this mission (220 mGy) corresponds to the accumulated dose that can be expected during a mission to Mars. We found that the recognition ability of fluorescently labeled aptamers was not significantly affected during short-term exposure experiments taking into account only one type of radiation at a time. However, we demonstrated that the same fluorescent dye was significantly affected by temperature variations (-21°C to +58°C) and storage throughout the entirety of the ISS experiment (60% of signal loss). This induced a large variability of aptamer signal in our analysis. However, we found that >50% of aptamers were still functional after the whole EXPOSE-R2 mission. We conclude that aptamer-based instruments are well suited for in situ analysis on planetary bodies, but the detection step requires additional investigations.
Collapse
Affiliation(s)
- Gaëlle Coussot
- 1Institut des Biomolécules Max Mousseron (IBMM), Université de Montpellier, CNRS, ENSCM, Montpellier, France
| | - Aurélie Le Postollec
- 2Laboratoire d'Astrophysique de Bordeaux (LAB), Université de Bordeaux, CNRS, B18N, Pessac, France
| | - Sébastien Incerti
- 3Centre d'Etudes Nucléaires de Bordeaux Gradignan (CENBG), UMR 5797, Université de Bordeaux, Gradignan, France
| | - Mickaël Baqué
- 4German Aerospace Center (DLR), Institute of Planetary Research, Management and Infrastructure, Research Group Astrobiological Laboratories, Berlin, Germany
| | | | - Odile Vandenabeele-Trambouze
- 6IUEM-UMR 6197, Laboratoire de Microbiologie des Environnements Extrêmes (LMEE), Université de Bretagne Occidentale (UBO), Plouzané, France
| | - Hervé Cottin
- 7Laboratoire Interuniversitaire des Systèmes Atmosphériques (LISA), UMR 7583, Université Paris Est Créteil et Université Paris Diderot, Institut Pierre Simon Laplace, Créteil, France
| | - Corinne Ravelet
- 8Département de Pharmacochimie Moléculaire, UMR 5063, Université Grenoble Alpes, CNRS, St. Martin d'Hères, France
| | - Eric Peyrin
- 8Département de Pharmacochimie Moléculaire, UMR 5063, Université Grenoble Alpes, CNRS, St. Martin d'Hères, France
| | - Emmanuelle Fiore
- 8Département de Pharmacochimie Moléculaire, UMR 5063, Université Grenoble Alpes, CNRS, St. Martin d'Hères, France
| | | | - Jérôme Caron
- 9Département de Radiothérapie, Institut Bergonié, Comprehensive Cancer Center, Bordeaux, France
| | - Didier Chaput
- 10DCT/ME/EM, Centre National d'Etudes Spatiales, Toulouse, France
| | - Bartos Przybyla
- 11German Aerospace Center, Institute of Aerospace Medicine, Cologne, Germany
| | - Thomas Berger
- 11German Aerospace Center, Institute of Aerospace Medicine, Cologne, Germany
| | - Michel Dobrijevic
- 2Laboratoire d'Astrophysique de Bordeaux (LAB), Université de Bordeaux, CNRS, B18N, Pessac, France
| |
Collapse
|
7
|
Blanco Y, de Diego-Castilla G, Viúdez-Moreiras D, Cavalcante-Silva E, Rodríguez-Manfredi JA, Davila AF, McKay CP, Parro V. Effects of Gamma and Electron Radiation on the Structural Integrity of Organic Molecules and Macromolecular Biomarkers Measured by Microarray Immunoassays and Their Astrobiological Implications. ASTROBIOLOGY 2018; 18:1497-1516. [PMID: 30070898 PMCID: PMC6276817 DOI: 10.1089/ast.2016.1645] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2016] [Accepted: 04/10/2018] [Indexed: 05/20/2023]
Abstract
High-energy ionizing radiation in the form of solar energetic particles and galactic cosmic rays is pervasive on the surface of planetary bodies with thin atmospheres or in space facilities for humans, and it may seriously affect the chemistry and the structure of organic and biological material. We used fluorescent microarray immunoassays to assess how different doses of electron and gamma radiations affect the stability of target compounds such as biological polymers and small molecules (haptens) conjugated to large proteins. The radiation effect was monitored by measuring the loss in the immunoidentification of the target due to an impaired ability of the antibodies for binding their corresponding irradiated and damaged epitopes (the part of the target molecule to which antibodies bind). Exposure to electron radiation alone was more damaging at low doses (1 kGy) than exposure to gamma radiation alone, but this effect was reversed at the highest radiation dose (500 kGy). Differences in the dose-effect immunoidentification patterns suggested that the amount (dose) and not the type of radiation was the main factor for the cumulative damage on the majority of the assayed molecules. Molecules irradiated with both types of radiation showed a response similar to that of the individual treatments at increasing radiation doses, although the pattern obtained with electrons only was the most similar. The calculated radiolysis constant did not show a unique pattern; it rather suggested a different behavior perhaps associated with the unique structure of each molecule. Although not strictly comparable with extraterrestrial conditions because the irradiations were performed under air and at room temperature, our results may contribute to understanding the effects of ionizing radiation on complex molecules and the search for biomarkers through bioaffinity-based systems in planetary exploration.
Collapse
Affiliation(s)
- Yolanda Blanco
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Torrejón de Ardoz, Madrid, Spain
| | - Graciela de Diego-Castilla
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Torrejón de Ardoz, Madrid, Spain
| | - Daniel Viúdez-Moreiras
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Torrejón de Ardoz, Madrid, Spain
| | - Erika Cavalcante-Silva
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Torrejón de Ardoz, Madrid, Spain
| | | | - Alfonso F. Davila
- Space Science Division, NASA Ames Research Center, Moffett Field, California, USA
| | - Christopher P. McKay
- Space Science Division, NASA Ames Research Center, Moffett Field, California, USA
| | - Victor Parro
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Torrejón de Ardoz, Madrid, Spain
- Address correspondence to: Victor Parro, Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Carretera de Ajalvir km 4, Torrejón de Ardoz, Madrid 28850, Spain
| |
Collapse
|
8
|
"The Smartphone's Guide to the Galaxy": In Situ Analysis in Space. BIOSENSORS-BASEL 2018; 8:bios8040096. [PMID: 30347742 PMCID: PMC6316803 DOI: 10.3390/bios8040096] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/14/2018] [Revised: 10/05/2018] [Accepted: 10/13/2018] [Indexed: 01/02/2023]
Abstract
A human mission to Mars can be viewed as the apex of human technological achievement. However, to make this dream a reality several obstacles need to be overcome. One is devising practical ways to safeguard the crew health during the mission through the development of easy operable and compact sensors. Lately, several smartphone-based sensing devices (SBDs) with the purpose to enable the immediate sensitive detection of chemicals, proteins or pathogens in remote settings have emerged. In this critical review, the potential to piggyback these systems for in situ analysis in space has been investigated on application of a systematic keyword search whereby the most relevant articles were examined comprehensively and existing SBDs were divided into 4 relevant groups for the monitoring of crew health during space missions. Recently developed recognition elements (REs), which could offer the enhanced ability to tolerate those harsh conditions in space, have been reviewed with recommendations offered. In addition, the potential use of cell free synthetic biology to obtain long-term shelf-stable reagents was reviewed. Finally, a synopsis of the possibilities of combining novel SBD, RE and nanomaterials to create a compact sensor-platform ensuring adequate crew health monitoring has been provided.
Collapse
|
9
|
Creamer JS, Mora MF, Willis PA. Stability of reagents used for chiral amino acid analysis during spaceflight missions in high‐radiation environments. Electrophoresis 2018; 39:2864-2871. [DOI: 10.1002/elps.201800274] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2018] [Revised: 08/28/2018] [Accepted: 08/29/2018] [Indexed: 11/08/2022]
Affiliation(s)
- Jessica S. Creamer
- Jet Propulsion LaboratoryCalifornia Institute of Technology Pasadena CA USA
| | - Maria F. Mora
- Jet Propulsion LaboratoryCalifornia Institute of Technology Pasadena CA USA
| | - Peter A. Willis
- Jet Propulsion LaboratoryCalifornia Institute of Technology Pasadena CA USA
| |
Collapse
|
10
|
Moreno-Paz M, Gómez-Cifuentes A, Ruiz-Bermejo M, Hofstetter O, Maquieira Á, Manchado JM, Morais S, Sephton MA, Niessner R, Knopp D, Parro V. Detecting Nonvolatile Life- and Nonlife-Derived Organics in a Carbonaceous Chondrite Analogue with a New Multiplex Immunoassay and Its Relevance for Planetary Exploration. ASTROBIOLOGY 2018; 18:1041-1056. [PMID: 29638146 PMCID: PMC6225596 DOI: 10.1089/ast.2017.1747] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Accepted: 01/18/2018] [Indexed: 05/05/2023]
Abstract
Potential martian molecular targets include those supplied by meteoritic carbonaceous chondrites such as amino acids and polycyclic aromatic hydrocarbons and true biomarkers stemming from any hypothetical martian biota (organic architectures that can be directly related to once living organisms). Heat extraction and pyrolysis-based methods currently used in planetary exploration are highly aggressive and very often modify the target molecules making their identification a cumbersome task. We have developed and validated a mild, nondestructive, multiplex inhibitory microarray immunoassay and demonstrated its implementation in the SOLID (Signs of Life Detector) instrument for simultaneous detection of several nonvolatile life- and nonlife-derived organic molecules relevant in planetary exploration and environmental monitoring. By utilizing a set of highly specific antibodies that recognize D- or L- aromatic amino acids (Phe, Tyr, Trp), benzo[a]pyrene (B[a]P), pentachlorophenol, and sulfone-containing aromatic compounds, respectively, the assay was validated in the SOLID instrument for the analysis of carbon-rich samples used as analogues of the organic material in carbonaceous chondrites or even Mars samples. Most of the antibodies enabled sensitivities at the 1-10 ppb level and some even at the ppt level. The multiplex immunoassay allowed the detection of B[a]P as well as aromatic sulfones in a water/methanol extract of an Early Cretaceous lignite sample (c.a., 140 Ma) representing type IV kerogen. No L- or D-aromatic amino acids were detected, reflecting the advanced diagenetic stage and the fossil nature of the sample. The results demonstrate the ability of the liquid extraction by ultrasonication and the versatility of the multiplex inhibitory immunoassays in the SOLID instrument to discriminate between organic matter derived from life and nonlife processes, an essential step toward life detection outside Earth.
Collapse
Affiliation(s)
- Mercedes Moreno-Paz
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Madrid, Spain
| | - Ana Gómez-Cifuentes
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Madrid, Spain
| | - Marta Ruiz-Bermejo
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Madrid, Spain
| | - Oliver Hofstetter
- Department of Chemistry and Biochemistry, Northern Illinois University, DeKalb, Illinois
| | - Ángel Maquieira
- Department of Chemistry, Instituto Universitario de Reconocimiento Molecular y Desarrollo Tecnológico, Universidad Politécnica de Valencia, Valencia, Spain
| | - Juan M. Manchado
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Madrid, Spain
| | - Sergi Morais
- Department of Chemistry, Instituto Universitario de Reconocimiento Molecular y Desarrollo Tecnológico, Universidad Politécnica de Valencia, Valencia, Spain
| | - Mark A. Sephton
- Department of Earth Science and Engineering, Imperial College London, London, United Kingdom
| | | | - Dietmar Knopp
- Department Chemie, Technische Universität München, Munich, Germany
| | - Victor Parro
- Department of Molecular Evolution, Centro de Astrobiología (INTA-CSIC), Madrid, Spain
| |
Collapse
|
11
|
Mathies RA, Razu ME, Kim J, Stockton AM, Turin P, Butterworth A. Feasibility of Detecting Bioorganic Compounds in Enceladus Plumes with the Enceladus Organic Analyzer. ASTROBIOLOGY 2017; 17:902-912. [PMID: 28915087 PMCID: PMC5610425 DOI: 10.1089/ast.2017.1660] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
Enceladus presents an excellent opportunity to detect organic molecules that are relevant for habitability as well as bioorganic molecules that provide evidence for extraterrestrial life because Enceladus' plume is composed of material from the subsurface ocean that has a high habitability potential and significant organic content. A primary challenge is to send instruments to Enceladus that can efficiently sample organic molecules in the plume and analyze for the most relevant molecules with the necessary detection limits. To this end, we present the scientific feasibility and engineering design of the Enceladus Organic Analyzer (EOA) that uses a microfluidic capillary electrophoresis system to provide sensitive detection of a wide range of relevant organic molecules, including amines, amino acids, and carboxylic acids, with ppm plume-detection limits (100 pM limits of detection). Importantly, the design of a capture plate that effectively gathers plume ice particles at encounter velocities from 200 m/s to 5 km/s is described, and the ice particle impact is modeled to demonstrate that material will be efficiently captured without organic decomposition. While the EOA can also operate on a landed mission, the relative technical ease of a fly-by mission to Enceladus, the possibility to nondestructively capture pristine samples from deep within the Enceladus ocean, plus the high sensitivity of the EOA instrument for molecules of bioorganic relevance for life detection argue for the inclusion of EOA on Enceladus missions. Key Words: Lab-on-a-chip-Organic biomarkers-Life detection-Planetary exploration. Astrobiology 17, 902-912.
Collapse
Affiliation(s)
- Richard A. Mathies
- Department of Chemistry, University of California at Berkeley, Berkeley, California
| | - Md Enayet Razu
- Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas
| | - Jungkyu Kim
- Department of Mechanical Engineering, Texas Tech University, Lubbock, Texas
| | - Amanda M. Stockton
- Department of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia
| | - Paul Turin
- Berkeley Space Sciences Lab, University of California at Berkeley, Berkeley, California
| | - Anna Butterworth
- Berkeley Space Sciences Lab, University of California at Berkeley, Berkeley, California
| |
Collapse
|
12
|
Karouia F, Peyvan K, Pohorille A. Toward biotechnology in space: High-throughput instruments for in situ biological research beyond Earth. Biotechnol Adv 2017; 35:905-932. [PMID: 28433608 DOI: 10.1016/j.biotechadv.2017.04.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2016] [Revised: 03/27/2017] [Accepted: 04/12/2017] [Indexed: 12/18/2022]
Abstract
Space biotechnology is a nascent field aimed at applying tools of modern biology to advance our goals in space exploration. These advances rely on our ability to exploit in situ high throughput techniques for amplification and sequencing DNA, and measuring levels of RNA transcripts, proteins and metabolites in a cell. These techniques, collectively known as "omics" techniques have already revolutionized terrestrial biology. A number of on-going efforts are aimed at developing instruments to carry out "omics" research in space, in particular on board the International Space Station and small satellites. For space applications these instruments require substantial and creative reengineering that includes automation, miniaturization and ensuring that the device is resistant to conditions in space and works independently of the direction of the gravity vector. Different paths taken to meet these requirements for different "omics" instruments are the subjects of this review. The advantages and disadvantages of these instruments and technological solutions and their level of readiness for deployment in space are discussed. Considering that effects of space environments on terrestrial organisms appear to be global, it is argued that high throughput instruments are essential to advance (1) biomedical and physiological studies to control and reduce space-related stressors on living systems, (2) application of biology to life support and in situ resource utilization, (3) planetary protection, and (4) basic research about the limits on life in space. It is also argued that carrying out measurements in situ provides considerable advantages over the traditional space biology paradigm that relies on post-flight data analysis.
Collapse
Affiliation(s)
- Fathi Karouia
- University of California San Francisco, Department of Pharmaceutical Chemistry, San Francisco, CA 94158, USA; NASA Ames Research Center, Exobiology Branch, MS239-4, Moffett Field, CA 94035, USA; NASA Ames Research Center, Flight Systems Implementation Branch, Moffett Field, CA 94035, USA.
| | | | - Andrew Pohorille
- University of California San Francisco, Department of Pharmaceutical Chemistry, San Francisco, CA 94158, USA; NASA Ames Research Center, Exobiology Branch, MS239-4, Moffett Field, CA 94035, USA.
| |
Collapse
|
13
|
McKay CP, Stoker CR, Glass BJ, Davé AI, Davila AF, Heldmann JL, Marinova MM, Fairen AG, Quinn RC, Zacny KA, Paulsen G, Smith PH, Parro V, Andersen DT, Hecht MH, Lacelle D, Pollard WH. The Icebreaker Life Mission to Mars: a search for biomolecular evidence for life. ASTROBIOLOGY 2013; 13:334-53. [PMID: 23560417 DOI: 10.1089/ast.2012.0878] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The search for evidence of life on Mars is the primary motivation for the exploration of that planet. The results from previous missions, and the Phoenix mission in particular, indicate that the ice-cemented ground in the north polar plains is likely to be the most recently habitable place that is currently known on Mars. The near-surface ice likely provided adequate water activity during periods of high obliquity, ≈ 5 Myr ago. Carbon dioxide and nitrogen are present in the atmosphere, and nitrates may be present in the soil. Perchlorate in the soil together with iron in basaltic rock provides a possible energy source for life. Furthermore, the presence of organics must once again be considered, as the results of the Viking GCMS are now suspect given the discovery of the thermally reactive perchlorate. Ground ice may provide a way to preserve organic molecules for extended periods of time, especially organic biomarkers. The Mars Icebreaker Life mission focuses on the following science goals: (1) Search for specific biomolecules that would be conclusive evidence of life. (2) Perform a general search for organic molecules in the ground ice. (3) Determine the processes of ground ice formation and the role of liquid water. (4) Understand the mechanical properties of the martian polar ice-cemented soil. (5) Assess the recent habitability of the environment with respect to required elements to support life, energy sources, and possible toxic elements. (6) Compare the elemental composition of the northern plains with midlatitude sites. The Icebreaker Life payload has been designed around the Phoenix spacecraft and is targeted to a site near the Phoenix landing site. However, the Icebreaker payload could be supported on other Mars landing systems. Preliminary studies of the SpaceX Dragon lander show that it could support the Icebreaker payload for a landing either at the Phoenix site or at midlatitudes. Duplicate samples could be cached as a target for possible return by a Mars Sample Return mission. If the samples were shown to contain organic biomarkers, interest in returning them to Earth would be high.
Collapse
|
14
|
Carr CE, Rowedder H, Vafadari C, Lui CS, Cascio E, Zuber MT, Ruvkun G. Radiation resistance of biological reagents for in situ life detection. ASTROBIOLOGY 2013; 13:68-78. [PMID: 23330963 DOI: 10.1089/ast.2012.0869] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Life on Mars, if it exists, may share a common ancestry with life on Earth derived from meteoritic transfer of microbes between the planets. One means to test this hypothesis is to isolate, detect, and sequence nucleic acids in situ on Mars, then search for similarities to known common features of life on Earth. Such an instrument would require biological and chemical components, such as polymerase and fluorescent dye molecules. We show that reagents necessary for detection and sequencing of DNA survive several analogues of the radiation expected during a 2-year mission to Mars, including proton (H-1), heavy ion (Fe-56, O-18), and neutron bombardment. Some reagents have reduced performance or fail at higher doses. Overall, our findings suggest it is feasible to utilize space instruments with biological components, particularly for mission durations of up to several years in environments without large accumulations of charged particles, such as the surface of Mars, and have implications for the meteoritic transfer of microbes between planets.
Collapse
Affiliation(s)
- Christopher E Carr
- Department of Earth, Atmospheric and Planetary Sciences, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA
| | | | | | | | | | | | | |
Collapse
|
15
|
Derveni M, Allen M, Sawakuchi GO, Yukihara EG, Richter L, Sims MR, Cullen DC. Survivability of immunoassay reagents exposed to the space radiation environment on board the ESA BIOPAN-6 platform as a prelude to performing immunoassays on Mars. ASTROBIOLOGY 2013; 13:92-102. [PMID: 23286207 DOI: 10.1089/ast.2012.0871] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The Life Marker Chip (LMC) instrument is an immunoassay-based sensor that will attempt to detect signatures of life in the subsurface of Mars. The molecular reagents at the core of the LMC have no heritage of interplanetary mission use; therefore, the design of such an instrument must take into account a number of risk factors, including the radiation environment that will be encountered during a mission to Mars. To study the effects of space radiation on immunoassay reagents, primarily antibodies, a space study was performed on the European Space Agency's 2007 BIOPAN-6 low-Earth orbit (LEO) space exposure platform to complement a set of ground-based radiation studies. Two antibodies were used in the study, which were lyophilized and packaged in the intended LMC format and loaded into a custom-made sample holder unit that was mounted on the BIOPAN-6 platform. The BIOPAN mission went into LEO for 12 days, after which all samples were recovered and the antibody binding performance was measured via enzyme-linked immunosorbent assays (ELISA). The factors expected to affect antibody performance were the physical conditions of a space mission and the exposure to space conditions, primarily the radiation environment in LEO. Both antibodies survived inactivation by these factors, as concluded from the comparison between the flight samples and a number of shipping and storage controls. This work, in combination with the ground-based radiation tests on representative LMC antibodies, has helped to reduce the risk of using antibodies in a planetary exploration mission context.
Collapse
Affiliation(s)
- Mariliza Derveni
- Cranfield Health, Cranfield University, Cranfield, United Kingdom.
| | | | | | | | | | | | | |
Collapse
|
16
|
Derveni M, Hands A, Allen M, Sims MR, Cullen DC. Effects of simulated space radiation on immunoassay components for life-detection experiments in planetary exploration missions. ASTROBIOLOGY 2012; 12:718-729. [PMID: 22897155 DOI: 10.1089/ast.2011.0727] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
The Life Marker Chip (LMC) instrument is part of the proposed payload on the ESA ExoMars rover that is scheduled for launch in 2018. The LMC will use antibody-based assays to detect molecular signatures of life in samples obtained from the shallow subsurface of Mars. For the LMC antibodies, the ability to resist inactivation due to space particle radiation (both in transit and on the surface of Mars) will therefore be a prerequisite. The proton and neutron components of the mission radiation environment are those that are expected to have the dominant effect on the operation of the LMC. Modeling of the radiation environment for a mission to Mars led to the calculation of nominal mission fluences for proton and neutron radiation. Various combinations and multiples of these values were used to demonstrate the effects of radiation on antibody activity, primarily at the radiation levels envisaged for the ExoMars mission as well as at much higher levels. Five antibodies were freeze-dried in a variety of protective molecular matrices and were exposed to various radiation conditions generated at a cyclotron facility. After exposure, the antibodies' ability to bind to their respective antigens was assessed and found to be unaffected by ExoMars mission level radiation doses. These experiments indicated that the expected radiation environment of a Mars mission does not pose a significant risk to antibodies packaged in the form anticipated for the LMC instrument.
Collapse
Affiliation(s)
- Mariliza Derveni
- Cranfield Health, Cranfield University, Cranfield, Bedfordshire, United Kingdom
| | | | | | | | | |
Collapse
|