1
|
Lacombe J, Zenhausern F. Effect of mechanical forces on cellular response to radiation. Radiother Oncol 2022; 176:187-198. [PMID: 36228760 DOI: 10.1016/j.radonc.2022.10.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 08/08/2022] [Accepted: 10/05/2022] [Indexed: 12/14/2022]
Abstract
While the cellular interactions and biochemical signaling has been investigated for long and showed to play a major role in the cell's fate, it is now also evident that mechanical forces continuously applied to the cells in their microenvironment are as important for tissue homeostasis. Mechanical cues are emerging as key regulators of cellular drug response and we aimed to demonstrate in this review that such effects should also be considered vital for the cellular response to radiation. In order to explore the mechanobiology of the radiation response, we reviewed the main mechanoreceptors and transducers, including integrin-mediated adhesion, YAP/TAZ pathways, Wnt/β-catenin signaling, ion channels and G protein-coupled receptors and showed their implication in the modulation of cellular radiosensitivity. We then discussed the current studies that investigated a direct effect of mechanical stress, including extracellular matrix stiffness, shear stress and mechanical strain, on radiation response of cancer and normal cells and showed through preliminary results that such stress effectively can alter cell response after irradiation. However, we also highlighted the limitations of these studies and emphasized some of the contradictory data, demonstrating that the effect of mechanical cues could involve complex interactions and potential crosstalk with numerous cellular processes also affected by irradiation. Overall, mechanical forces alter radiation response and although additional studies are required to deeply understand the underlying mechanisms, these effects should not be neglected in radiation research as they could reveal new fundamental knowledge for predicting radiosensitivity or understanding resistance to radiotherapy.
Collapse
Affiliation(s)
- Jerome Lacombe
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, 475 North 5th Street, Phoenix, AZ 85004, USA; Department of Basic Medical Sciences, College of Medicine Phoenix, University of Arizona, 425 N 5th St, Phoenix, AZ 85004, USA.
| | - Frederic Zenhausern
- Center for Applied NanoBioscience and Medicine, College of Medicine Phoenix, University of Arizona, 475 North 5th Street, Phoenix, AZ 85004, USA; Department of Basic Medical Sciences, College of Medicine Phoenix, University of Arizona, 425 N 5th St, Phoenix, AZ 85004, USA; Department of Biomedical Engineering, College of Engineering, University of Arizona, 1127 E. James E. Rogers Way, Tucson, AZ 85721, USA.
| |
Collapse
|
2
|
Pumping the Periosteum: A Feasibility Study: Periosteal Distraction Osteogenesis in a Rat Model. Ann Plast Surg 2022; 89:218-224. [PMID: 35276708 DOI: 10.1097/sap.0000000000003108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
PURPOSE Gradual elevation of periosteum from the bone surface is known to promote the adaptation of soft tissues and the formation of hard tissues. The aim of our study was to estimate the benefit of periosteal distraction osteogenesis (PDO) on de novo bone formation in a rat model. MATERIALS AND METHODS After device placement, animals were allowed for a latency period of 7 days. Animals in the PDO group were subjected to distraction at a rate of 0.1 mm/d for 10 days. In the periosteal pumping (PP) group, the animals were subjected to distraction at a rate of 0.1 mm/d. The direction of distraction was alternated every 2 days. The animals were euthanized at 17, 31, and 45 days after surgery, and the samples were analyzed histologically and by microcomputed tomography. RESULTS In both groups, the new bone was characterized as primary woven bone that was located at the leading edge of bone apposition. Bone volumes significantly increased throughout the observation period both in the PP group (P = 0.018) and in the PDO group (P < 0.001). The new bone was denser and more mature in the PP group than in the PDO group, and the difference was significant at the 31-day time point (P = 0.024). However, the volume of the new bone was higher in the PDO at the 45-day time point (P < 0.001). CONCLUSIONS We propose that the PP may be applied to enhance the osteogenic capacity of periosteum without plate elevation. Because this is only a proof-of-principle study, the alternated protocol of periosteal distraction warrants evaluation in the future studies.
Collapse
|
3
|
Saulacic N, García-González M, Muñoz Guzon FM, Garcia Garcia A, Sadath-Marashi Z, Rohrer U, Ferrari SL. Regeneration of Craniofacial Bone Induced by Periosteal Pumping. Tissue Eng Part C Methods 2022; 28:61-72. [PMID: 35107342 DOI: 10.1089/ten.tec.2022.0001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
A variety of surgical techniques and tissue engineering strategies utilizing osteogenic potential of the periosteum have been developed for the repair of extended bone deficiencies. The aim of the present study was to assess the impact of an alternating protocol of periosteal distraction osteogenesis (PDO) on bone regeneration in an intraoral model. Eight adult, male Beagle dogs were used for the study. Two distraction devices were placed on each side of the mandible. After a 7-day latency period, distraction devices in all animals were manipulated at the rate of 0.5 mm for a total of 8 days. The pumping protocol in two test groups proceeded twice daily by alternating activation with relaxation. In the periosteal pumping/distraction (PPDO) group, the distraction screws were activated two times (at 12 and 24 h) and then turned back (at 36 h), and in the periosteal pumping (PP) group repeatedly activated and turned back (at 12 h). In the PDO group, only activation was performed once daily (positive control). Devices were left inactivated in the negative control (NC) group. The samples were harvested after 8 weeks of consolidation period and investigated by micro-CT and histological analysis. New mature, lamellar bone was formed over the pristine bone in all groups. PPDO and PDO groups showed more new bone area (NBA) compared to the PP (p < 0.001 and p < 0.001, respectively) and to the NC group (p = 0.032 and p = 0.031, respectively). Furthermore, greater NBA was found in the PP group than the NC group (p = 0.006). PDO demonstrated higher relative connective tissue area than the PPDO group (p = 0.005) and lower relative new bone volume than the NC group (p = 0.025). Pumping protocol of periosteal distraction may successfully induce the endogenous regeneration of the mandibular bone in dogs. Impact Statement Repair of extended bone defects impose a significant challenge to oral and maxillofacial surgeons. In this article, a principle of distraction osteogenesis was applied to stimulate bone regeneration in the mandible. A periosteum-based regeneration approach may represent a valuable step toward creating a significant volume of hard and soft tissues, without need for autogenous bone harvesting or application of biomaterials.
Collapse
Affiliation(s)
- Nikola Saulacic
- Department of Cranio-Maxillofacial Surgery, Inselspital, University Hospital Bern, University of Bern, Bern, Switzerland
| | - Mario García-González
- Department of Veterinary Clinical Sciences, Faculty of Veterinary, University of Santiago de Compostela, Lugo, Spain
| | - Fernando M Muñoz Guzon
- Department of Veterinary Clinical Sciences, Faculty of Veterinary, University of Santiago de Compostela, Lugo, Spain
| | - Abel Garcia Garcia
- Department of Maxillofacial Surgery, Complejo Hospitalario Universitario de Santiago de Compostela and Oral Surgery Unit, School of Dentistry, University of Santiago de Compostela, Santiago de Compostela, Spain
| | - Zahra Sadath-Marashi
- Department of Cranio-Maxillofacial Surgery, Inselspital, University Hospital Bern, University of Bern, Bern, Switzerland
| | - Urs Rohrer
- ARTORG Center for Biomedical Engineering, University of Bern, Bern, Switzerland
| | - Serge L Ferrari
- Division of Bone Diseases, Department of Internal Medicine Specialties, Geneva University Hospital and Faculty of Medicine, Genève, Switzerland
| |
Collapse
|
4
|
Fereidoonnezhad B, Moerman KM, Johnson S, McCarthy R, McGarry PJ. A new compressible hyperelastic model for the multi-axial deformation of blood clot occlusions in vessels. Biomech Model Mechanobiol 2021; 20:1317-1335. [PMID: 33818678 DOI: 10.1007/s10237-021-01446-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Accepted: 03/06/2021] [Indexed: 10/21/2022]
Abstract
Mechanical thrombectomy can be significantly affected by the mechanical properties of the occluding thrombus. In this study, we provide the first characterisation of the volumetric behaviour of blood clots. We propose a new hyperelastic model for the volumetric and isochoric deformation of clot. We demonstrate that the proposed model provides significant improvements over established models in terms of accurate prediction of nonlinear stress-strain and volumetric behaviours of clots with low and high red blood cell compositions. We perform a rigorous investigation of the factors that govern clot occlusion of a tapered vessel. The motivation for such an analysis is twofold: (i) the role of clot composition on the in vivo occlusion location is an open clinical question that has significant implications for thrombectomy procedures; (ii) in vitro measurement of occlusion location in an engineered tapered tube can be used as a quick and simple methodology to assess the mechanical properties/compositions of clots. Simulations demonstrate that both isochoric and volumetric behaviours of clots are key determinants of clot lodgement location, in addition to clot-vessel friction. The proposed formulation is shown to provide accurate predictions of in vitro measurement of clot occlusion location in a silicone tapered vessel, in addition to accurately predicting the deformed shape of the clot.
Collapse
Affiliation(s)
| | - Kevin M Moerman
- Biomedical Engineering, National University of Ireland Galway, Galway, Ireland
| | - Sarah Johnson
- Cerenovus Galway Neuro-Technology Centre, Johnson & Johnson, Galway, Ireland
| | - Ray McCarthy
- Cerenovus Galway Neuro-Technology Centre, Johnson & Johnson, Galway, Ireland
| | - Patrick J McGarry
- Biomedical Engineering, National University of Ireland Galway, Galway, Ireland.
| |
Collapse
|
5
|
Reynolds NH, McEvoy E, Panadero Pérez JA, Coleman RJ, McGarry JP. Influence of multi-axial dynamic constraint on cell alignment and contractility in engineered tissues. J Mech Behav Biomed Mater 2020; 112:104024. [PMID: 33007624 DOI: 10.1016/j.jmbbm.2020.104024] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2019] [Revised: 07/29/2020] [Accepted: 08/01/2020] [Indexed: 10/23/2022]
Abstract
In this study an experimental rig is developed to investigate the influence of tissue constraint and cyclic loading on cell alignment and active cell force generation in uniaxial and biaxial engineered tissues constructs. Addition of contractile cells to collagen hydrogels dramatically increases the measured forces in uniaxial and biaxial constructs under dynamic loading. This increase in measured force is due to active cell contractility, as is evident from the decreased force after treatment with cytochalasin D. Prior to dynamic loading, cells are highly aligned in uniaxially constrained tissues but are uniformly distributed in biaxially constrained tissues, demonstrating the importance of tissue constraints on cell alignment. Dynamic uniaxial stretching resulted in a slight increase in cell alignment in the centre of the tissue, whereas dynamic biaxial stretching had no significant effect on cell alignment. Our active modelling framework accurately predicts our experimental trends and suggests that a slightly higher (3%) total SF formation occurs at the centre of a biaxial tissue compared to the uniaxial tissue. However, high alignment of SFs and lateral compaction in the case of the uniaxially constrained tissue results in a significantly higher (75%) actively generated cell contractile stress, compared to the biaxially constrained tissue. These findings have significant implications for engineering of contractile tissue constructs.
Collapse
Affiliation(s)
- Noel H Reynolds
- Department of Biomedical Engineering, National University of Ireland, Galway, Ireland
| | - Eoin McEvoy
- Department of Biomedical Engineering, National University of Ireland, Galway, Ireland
| | | | - Ryan J Coleman
- Department of Biomedical Engineering, National University of Ireland, Galway, Ireland
| | - J Patrick McGarry
- Department of Biomedical Engineering, National University of Ireland, Galway, Ireland.
| |
Collapse
|
6
|
Dissaux C, Wagner D, George D, Spingarn C, Rémond Y. Mechanical impairment on alveolar bone graft: A literature review. J Craniomaxillofac Surg 2019; 47:149-157. [DOI: 10.1016/j.jcms.2018.10.020] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Revised: 10/08/2018] [Accepted: 10/30/2018] [Indexed: 10/27/2022] Open
|
7
|
Wang M, Yang N. A review of bioregulatory and coupled mechanobioregulatory mathematical models for secondary fracture healing. Med Eng Phys 2017; 48:90-102. [DOI: 10.1016/j.medengphy.2017.06.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Revised: 05/18/2017] [Accepted: 06/18/2017] [Indexed: 01/09/2023]
|
8
|
A review of computational models of bone fracture healing. Med Biol Eng Comput 2017; 55:1895-1914. [DOI: 10.1007/s11517-017-1701-3] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2017] [Accepted: 07/25/2017] [Indexed: 12/22/2022]
|
9
|
Single cell active force generation under dynamic loading - Part I: AFM experiments. Acta Biomater 2015; 27:236-250. [PMID: 26360596 DOI: 10.1016/j.actbio.2015.09.006] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 08/14/2015] [Accepted: 09/06/2015] [Indexed: 12/27/2022]
Abstract
A novel series of experiments are performed on single cells using a bespoke AFM system where the response of cells to dynamic loading at physiologically relevant frequencies is uncovered. Measured forces for the untreated cells are dramatically different to cytochalasin-D (cyto-D) treated cells, indicating that the contractile actin cytoskeleton plays a critical role in the response of cells to dynamic loading. Following a change in applied strain magnitude, while maintaining a constant applied strain rate, the compression force for contractile cells recovers to 88.9±7.8% of the steady state force. In contrast, cyto-D cell compression forces recover to only 38.0±6.7% of the steady state force. Additionally, untreated cells exhibit strongly negative (pulling) forces during unloading half-cycles when the probe is retracted. In comparison, negligible pulling forces are measured for cyto-D cells during probe retraction. The current study demonstrates that active contractile forces, generated by actin-myosin cross-bridge cycling, dominate the response of single cells to dynamic loading. Such active force generation is shown to be independent of applied strain magnitude. Passive forces generated by the applied deformation are shown to be of secondary importance, exhibiting a high dependence on applied strain magnitude, in contrast to the active forces in untreated cells. STATEMENT OF SIGNIFICANCE A novel series of experiments are performed on single cells using a bespoke AFM system where the response of cells to dynamic loading at physiologically relevant frequencies is uncovered. Contractile cells, which contain the active force generation machinery of the actin cytoskeleton, are shown to be insensitive to applied strain magnitude, exhibiting high resistance to dynamic compression and stretching. Such trends are not observed for cells in which the actin cytoskeleton has been chemically disrupted. These biomechanical insights have not been previously reported. This detailed characterisation of single cell active and passive stress during dynamic loading has important implications for tissue engineering strategies, where applied deformation has been reported to significantly affect cell mechanotransduction and matrix synthesis.
Collapse
|
10
|
Slack GC, Fan KL, Tabit C, Andrews B, Hindin DI, Kawamoto HK, Bradley JP. Necessity of latency period in craniofacial distraction: Investigations with in vitro microdistractor and clinical outcomes. J Plast Reconstr Aesthet Surg 2015; 68:1206-14. [PMID: 26261092 DOI: 10.1016/j.bjps.2015.04.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2013] [Revised: 02/10/2015] [Accepted: 04/13/2015] [Indexed: 11/26/2022]
Abstract
BACKGROUND To determine the need for latency period in membranous bone distraction, we performed 1) in vitro comparison of preosteoblasts suspended in a 3D microdistraction model and 2) a clinical study comparing mandibular distraction cases with/without latency. METHODS In the In Vitro study, Preosteoblasts polymerized in 3D-collagen gel were placed in a microdistractor and separated into three groups: 1) distraction with latency, 2) distraction without latency, and 3) static. After 2, 4, 6, and 8 days, cell proliferation, total protein levels, alkaline phosphatase activity, and osteogenic gene expression were assessed through RT-PCR. In the clinical study, patients underwent mandibular distraction in two groups: 1) latency and 2) no latency (n = 45). The rest of the distraction protocol was identical. Outcome was based on clinical examination, radiographs at six months, and 3D CT scans. RESULTS In the In Vitro study, The distraction without latency group compared to the latency group had delays in: proliferation, total protein count, alkaline phosphatase activity, osteogenic gene expression in CBFA-1 (fourfold vs. eighteenfold), and in osteocalcin (twofold vs. sixfold). The distraction without latency group had higher apoptotic levels during the first four days compared to the latency group (68% vs. 14%). For the clinical study, similar perioperative complications (5% vs. 6%), X-ray mineralization (93% vs. 94%), bone volume, (8.6 vs. 9.1 cc) and bone density of central distraction zone (78% vs. 81%) were observed with or without latency. CONCLUSIONS In vitro studies showed poorer results in cell survival, proliferation and osteogenic activity compared to distraction with latency; yet, clinically, there were no differences in distraction with latency versus without.
Collapse
Affiliation(s)
- Ginger C Slack
- Division of Plastic and Reconstructive Surgery, David Geffen School of Medicine, Los Angeles, CA, USA
| | - Kenneth L Fan
- Division of Plastic and Reconstructive Surgery, David Geffen School of Medicine, Los Angeles, CA, USA
| | - Christina Tabit
- Division of Plastic and Reconstructive Surgery, David Geffen School of Medicine, Los Angeles, CA, USA
| | - Brian Andrews
- Division of Plastic and Reconstructive Surgery, David Geffen School of Medicine, Los Angeles, CA, USA
| | - David I Hindin
- Division of Plastic and Reconstructive Surgery, David Geffen School of Medicine, Los Angeles, CA, USA
| | - Henry K Kawamoto
- Division of Plastic and Reconstructive Surgery, David Geffen School of Medicine, Los Angeles, CA, USA
| | - James P Bradley
- Division of Plastic and Reconstructive Surgery, David Geffen School of Medicine, Los Angeles, CA, USA.
| |
Collapse
|
11
|
Wehner T, Gruchenberg K, Bindl R, Recknagel S, Steiner M, Ignatius A, Claes L. Temporal delimitation of the healing phases via monitoring of fracture callus stiffness in rats. J Orthop Res 2014; 32:1589-95. [PMID: 25183200 DOI: 10.1002/jor.22721] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Accepted: 07/22/2014] [Indexed: 02/04/2023]
Abstract
The healing process consists of at least three phases: inflammatory, repair, and remodeling phase. Because callus stiffness correlates with the healing phases, it is suitable for evaluating the fracture healing process. Our aim was to develop a method which allows determination of callus stiffness in vivo, the healing time and the duration of the repair phase. The right femurs of 16 Wistar rats were osteotomized and stabilized with either more rigid or more flexible external fixation. Fixator deformation was measured using strain gauges during gait analysis. The strains were recalculated as the callus stiffness over the time course of healing, and the healing phases were identified based on stiffness thresholds. Our hypothesis was that stabilization with more flexible external fixation prolongs the repair phase, therefore resulting in an extended healing time. Confirming our hypothesis, the duration of the repair phase (rigid: approximately 15 days, flexible: approximately 41 days) and the healing time (rigid: approximately 27 days, flexible: approximately 62 days) were significantly longer for more flexible external fixation. Our method allows the quantitative detection of differences in the healing time and duration of the repair phase without multiple time-point sacrifices, which reduces the number of animals in experimental studies.
Collapse
Affiliation(s)
- Tim Wehner
- Institute of Orthopaedic Research and Biomechanics, Center of Musculoskeletal Research, Ulm University, Helmholtzstrasse 14, 89081, Ulm, Germany
| | | | | | | | | | | | | |
Collapse
|
12
|
Wilson CJ, Pearcy MJ, Epari DR. Mechanical tension as a driver of connective tissue growth in vitro. Med Hypotheses 2014; 83:111-5. [DOI: 10.1016/j.mehy.2014.03.031] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2013] [Accepted: 03/27/2014] [Indexed: 10/25/2022]
|
13
|
Weafer PP, Ronan W, Jarvis SP, McGarry JP. Experimental and computational investigation of the role of stress fiber contractility in the resistance of osteoblasts to compression. Bull Math Biol 2013; 75:1284-303. [PMID: 23354930 DOI: 10.1007/s11538-013-9812-y] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2012] [Accepted: 01/08/2013] [Indexed: 10/27/2022]
Abstract
The mechanical behavior of the actin cytoskeleton has previously been investigated using both experimental and computational techniques. However, these investigations have not elucidated the role the cytoskeleton plays in the compression resistance of cells. The present study combines experimental compression techniques with active modeling of the cell's actin cytoskeleton. A modified atomic force microscope is used to perform whole cell compression of osteoblasts. Compression tests are also performed on cells following the inhibition of the cell actin cytoskeleton using cytochalasin-D. An active bio-chemo-mechanical model is employed to predict the active remodeling of the actin cytoskeleton. The model incorporates the myosin driven contractility of stress fibers via a muscle-like constitutive law. The passive mechanical properties, in parallel with active stress fiber contractility parameters, are determined for osteoblasts. Simulations reveal that the computational framework is capable of predicting changes in cell morphology and increased resistance to cell compression due to the contractility of the actin cytoskeleton. It is demonstrated that osteoblasts are highly contractile and that significant changes to the cell and nucleus geometries occur when stress fiber contractility is removed.
Collapse
Affiliation(s)
- P P Weafer
- Department of Mechanical and Biomedical Engineering, National University of Ireland, Galway, Ireland
| | | | | | | |
Collapse
|
14
|
Immediate semi-static loading using compression healing abutments: a stability study in dogs. Res Vet Sci 2011; 93:484-7. [PMID: 21911236 DOI: 10.1016/j.rvsc.2011.07.023] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2011] [Accepted: 07/30/2011] [Indexed: 11/22/2022]
Abstract
Loading in implant dentistry to accelerate prosthodontic treatment has been receiving increasing interest. The aim of this study was to investigate the effect of an early controlled lateral loading (after 7 days) on the establishment of osseointegration by means of resonance frequency analysis. Two groups of six beagle dogs each were used. Group I had implants without loading. Group II had implants loaded with a new prototype compression abutment that created controlled semi-static loading. Loaded implants showed slightly better stability after 5 weeks of healing, but the difference was not significant. We concluded that controlled loading is beneficial to maintain, and even improve, stability during the early critical healing period.
Collapse
|
15
|
Gurkan UA, Krueger A, Akkus O. Ossifying Bone Marrow Explant Culture as a Three-Dimensional MechanoresponsiveIn VitroModel of Osteogenesis. Tissue Eng Part A 2011; 17:417-28. [PMID: 20807016 DOI: 10.1089/ten.tea.2010.0193] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
Affiliation(s)
- Umut Atakan Gurkan
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
| | - Adam Krueger
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
| | - Ozan Akkus
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana
| |
Collapse
|
16
|
Weiss S, Henle P, Roth W, Bock R, Boeuf S, Richter W. Design and characterization of a new bioreactor for continuous ultra-slow uniaxial distraction of a three-dimensional scaffold-free stem cell culture. Biotechnol Prog 2010; 27:86-94. [DOI: 10.1002/btpr.510] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2010] [Revised: 07/14/2010] [Indexed: 01/13/2023]
|
17
|
Prè D, Ceccarelli G, Benedetti L, Magenes G, De Angelis MGC. Effects of low-amplitude, high-frequency vibrations on proliferation and differentiation of SAOS-2 human osteogenic cell line. Tissue Eng Part C Methods 2010; 15:669-79. [PMID: 19257810 DOI: 10.1089/ten.tec.2008.0599] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
The aim of the work was to understand the consequences of low-amplitude, high-frequency vibrations on proliferation and differentiation of SAOS-2 cells (sarcoma osteogenetic), an osteoblastic and tumorigenic cell line. We realized a bioreactor composed of an eccentric motor that produces a displacement of 11 mm at frequencies between 1 and 120 Hz on a plate connected to the motor. The cultures of SAOS-2 cells were fixed on the plate, and the linear acceleration provoked by the motor to the cultures was measured. We used 30 Hz as stimulating frequency after a preliminary test on the effect of different frequencies on differentiation of cells. Afterward, SAOS-2 cells were stimulated with 30 Hz for different durations, every day for 4 days. The expression of some genes involved in the differentiation process was analyzed first with a reverse transcriptase-polymerase chain reaction and afterward with a real-time polymerase chain reaction on the most expressed genes. Moreover, the proliferation of cells was evaluated. The results suggest a strong increase in the expression of the genes involved in tissue differentiation in the treated groups with respect to the controls. On the other hand, the proliferation seems to be slowed down, so probably the acceleration perceived by the mechanosensors of the cells changes the cellular cycle by blocking the duplication to early differentiate toward bone tissue.
Collapse
Affiliation(s)
- Deborah Prè
- Dipartimento di Informatica e Sistemistica, University of Pavia , Pavia, Italy.
| | | | | | | | | |
Collapse
|
18
|
Geris L, Vander Sloten J, Van Oosterwyck H. In silico biology of bone modelling and remodelling: regeneration. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2009; 367:2031-2053. [PMID: 19380324 DOI: 10.1098/rsta.2008.0293] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
Bone regeneration is the process whereby bone is able to (scarlessly) repair itself from trauma, such as fractures or implant placement. Despite extensive experimental research, many of the mechanisms involved still remain to be elucidated. Over the last decade, many mathematical models have been established to investigate the regeneration process in silico. The first models considered only the influence of the mechanical environment as a regulator of the healing process. These models were followed by the development of bioregulatory models where mechanics was neglected and regeneration was regulated only by biological stimuli such as growth factors. The most recent mathematical models couple the influences of both biological and mechanical stimuli. Examples are given to illustrate the added value of mathematical regeneration research, specifically in the in silico design of treatment strategies for non-unions. Drawbacks of the current continuum-type models, together with possible solutions in extending the models towards other time and length scales are discussed. Finally, the demands for dedicated and more quantitative experimental research are presented.
Collapse
Affiliation(s)
- L Geris
- Division of Biomechanics and Engineering Design, Katholieke Universiteit Leuven, Celestijnenlaan 300C, PB 2419, 3001 Leuven, Belgium.
| | | | | |
Collapse
|
19
|
Biological Basis of Bone Formation, Remodeling, and Repair—Part III: Biomechanical Forces. TISSUE ENGINEERING PART B-REVIEWS 2008; 14:285-93. [DOI: 10.1089/ten.teb.2008.0084] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
20
|
Panetta NJ, Gupta DM, Slater BJ, Kwan MD, Liu KJ, Longaker MT. Tissue engineering in cleft palate and other congenital malformations. Pediatr Res 2008; 63:545-51. [PMID: 18427300 DOI: 10.1203/pdr.0b013e31816a743e] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Contributions from multidisciplinary investigations have focused attention on the potential of tissue engineering to yield novel therapeutics. Congenital malformations, including cleft palate, craniosynostosis, and craniofacial skeletal hypoplasias represent excellent targets for the implementation of tissue engineering applications secondary to the technically challenging nature and inherent inadequacies of current reconstructive interventions. Apropos to the search for answers to these clinical conundrums, studies have focused on elucidating the molecular signals driving the biologic activity of the aforementioned maladies. These investigations have highlighted multiple signaling pathways, including Wnt, fibroblast growth factor, transforming growth factor-beta, and bone morphogenetic proteins, that have been found to play critical roles in guided tissue development. Furthermore, a comprehensive knowledge of these pathways will be of utmost importance to the optimization of future cell-based tissue engineering strategies. The scope of this review encompasses a discussion of the molecular biology involved in the development of cleft palate and craniosynostosis. In addition, we include a discussion of craniofacial distraction osteogenesis and how its applied forces influence cell signaling to guide endogenous bone regeneration. Finally, this review discusses the future role of cell-based tissue engineering in the treatment of congenital malformations.
Collapse
Affiliation(s)
- Nicholas J Panetta
- Department of Surgery, Stanford University School of Medicine, Stanford, CA 94305-5148, USA
| | | | | | | | | | | |
Collapse
|
21
|
Rath B, Nam J, Knobloch TJ, Lannutti JJ, Agarwal S. Compressive forces induce osteogenic gene expression in calvarial osteoblasts. J Biomech 2008; 41:1095-103. [PMID: 18191137 DOI: 10.1016/j.jbiomech.2007.11.024] [Citation(s) in RCA: 138] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2007] [Revised: 11/29/2007] [Accepted: 11/29/2007] [Indexed: 11/28/2022]
Abstract
Bone cells and their precursors are sensitive to changes in their biomechanical environment. The importance of mechanical stimuli has been observed in bone homeostasis and osteogenesis, but the mechanisms responsible for osteogenic induction in response to mechanical signals are poorly understood. We hypothesized that compressive forces could exert an osteogenic effect on osteoblasts and act in a dose-dependent manner. To test our hypothesis, electrospun poly(epsilon-caprolactone) (PCL) scaffolds were used as a 3-D microenvironment for osteoblast culture. The scaffolds provided a substrate allowing cell exposure to levels of externally applied compressive force. Pre-osteoblasts adhered, proliferated and differentiated in the scaffolds and showed extensive matrix synthesis by scanning electron microscopy (SEM) and increased Young's modulus (136.45+/-9.15 kPa) compared with acellular scaffolds (24.55+/-8.5 kPa). Exposure of cells to 10% compressive strain (11.81+/-0.42 kPa) resulted in a rapid induction of bone morphogenic protein-2 (BMP-2), runt-related transcription factor 2 (Runx2), and MAD homolog 5 (Smad5). These effects further enhanced the expression of genes and proteins required for extracellular matrix (ECM) production, such as alkaline phosphatase (Akp2), collagen type I (Col1a1), osteocalcin/bone gamma carboxyglutamate protein (OC/Bglap), osteonectin/secreted acidic cysteine-rich glycoprotein (ON/Sparc) and osteopontin/secreted phosphoprotein 1 (OPN/Spp1). Exposure of cell-scaffold constructs to 20% compressive strain (30.96+/-2.82 kPa) demonstrated that these signals are not osteogenic. These findings provide the molecular basis for the experimental and clinical observations that appropriate physical activities or microscale compressive loading can enhance fracture healing due in part to the anabolic osteogenic effects.
Collapse
Affiliation(s)
- Bjoern Rath
- Biomechanics and Tissue Engineering Laboratory, The Ohio State University, 4010 Postle Hall, Columbus, OH 43210, USA
| | | | | | | | | |
Collapse
|