1
|
Trimboli P, Bini F, Marinozzi F, Baek JH, Giovanella L. High-intensity focused ultrasound (HIFU) therapy for benign thyroid nodules without anesthesia or sedation. Endocrine 2018; 61:210-215. [PMID: 29453658 DOI: 10.1007/s12020-018-1560-1] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2017] [Accepted: 02/04/2018] [Indexed: 01/07/2023]
Abstract
BACKGROUND Thermal ablation of thyroid nodules has gained momentum due to the possibility to avoid surgery. High-intensity focused ultrasound (HIFU) allows thermal treatment by energy ultrasound beam inside the targeted zone. Aim of our study was to evaluate the effects of HIFU treatment using Beamotion mode without anesthesia. METHODS Since 2016, patients with normal thyroid function, benign thyroid nodules with diameter no larger than 4 cm, and presenting local discomfort and/or compressive symptoms were treated by HIFU. We performed Beamotion HIFU and did not use anesthesia. Nodule size and thyroid function were evaluated before HIFU and 6 and 12 months later. Complications to therapy and tolerability of patients were also recorded. According to local ethical committee, for this retrospective study formal consent was not required. RESULTS The final series included 26 nodules from 26 patients with estimated volume of 2.81 ± 2.04 mL, treated by a power of 33.3 ± 10.3 W/site and energy of 2.1 ± 1.1 kJ. Nodules volume was significantly (p < 0.0001) reduced at 6 months of follow-up (1.83 ± 1.63 mL), and further at 1 year (1.57 ± 1.47 mL). Mean percentage of reduction over time of nodules was 48%. A 73% of patients described good comfort during treatment, 100% experienced good comfort just after therapy, and tolerability was high. No complications were recorded. At one 1 year of follow-up, 85% of subjects reported a reduction of local symptoms. CONCLUSIONS HIFU therapy is effective in reducing size of thyroid nodules with major diameter below 4 cm and can be performed without anesthesia.
Collapse
Affiliation(s)
- Pierpaolo Trimboli
- Department of Nuclear Medicine and Thyroid Centre, Oncology Institute of Southern Switzerland, Bellinzona, 6500, Switzerland.
| | - Fabiano Bini
- Department of Mechanical and Aerospace Engineering, "Sapienza" University of Rome, Rome, 00184, Italy
| | - Franco Marinozzi
- Department of Mechanical and Aerospace Engineering, "Sapienza" University of Rome, Rome, 00184, Italy
| | - Jung Hwan Baek
- Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, 05505, Korea
| | - Luca Giovanella
- Department of Nuclear Medicine and Thyroid Centre, Oncology Institute of Southern Switzerland, Bellinzona, 6500, Switzerland
| |
Collapse
|
2
|
Multimodal Approach for Treating Horizontal Neck Wrinkles Using Intensity Focused Ultrasound, Cohesive Polydensified Matrix Hyaluronic Acid, and IncobotulinumtoxinA. Dermatol Surg 2018; 44:421-431. [DOI: 10.1097/dss.0000000000001312] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
3
|
Bini F, Trimboli P, Marinozzi F, Giovanella L. Treatment of benign thyroid nodules by high intensity focused ultrasound (HIFU) at different acoustic powers: a study on in-silico phantom. Endocrine 2018. [PMID: 28638983 DOI: 10.1007/s12020-017-1350-1] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
BACKGROUND The non-surgical therapies of benign thyroid nodules are gaining momentum due to the possibility to reduce the nodule's volume and avoid surgery. As the last technique introduced, high intensity focused ultrasound allows the thermal tissue treatment by directing energy inside the targeted nodule with no invasive instruments. In the present study we applied the Food and Drug Administration high intensity focused ultrasound simulator to in-silico phantom to evaluate the effects obtained by different acoustic powers. METHODS The simulated layers were water and thyroid tissue. The source was a spherically curved circular transducer with radius r = 2.3 cm generating a continuous wave beam at a frequency of 3 MHz. The focal distance was 6.5 cm. The sequence included a pulse (8 s) with acoustic power at different value from 5 to 50 W, and a cooling-off interval (32 s). RESULTS The use of acoustic power of 5 W allowed to achieve the threshold of temperature for coagulative necrosis (55 °C) at 1 s. The simulation with 50 W showed that temperature was significantly higher (above 300 °C) at 1 s and is maintained at high levels for a long interval. CONCLUSION Since 2016, we treated patients according to the present experience, and a significant reduction of nodule's volume was observed with good patent's comfort and no complications (unpublished data). Also, no anesthesia was practiced. We feel that the present data could contribute to develop a high intensity focused ultrasound therapy of benign thyroid nodules free from potential complications.
Collapse
Affiliation(s)
- Fabiano Bini
- Department of Nuclear Medicine and Thyroid Centre, Oncology Institute of Southern Switzerland, Via Ospedale 12, 6500, Bellinzona, Switzerland
- Department of Mechanical and Aerospace Engineering, "Sapienza" University of Rome, Rome, Italy
| | - Pierpaolo Trimboli
- Department of Nuclear Medicine and Thyroid Centre, Oncology Institute of Southern Switzerland, Via Ospedale 12, 6500, Bellinzona, Switzerland.
| | - Franco Marinozzi
- Department of Mechanical and Aerospace Engineering, "Sapienza" University of Rome, Rome, Italy
| | - Luca Giovanella
- Department of Nuclear Medicine and Thyroid Centre, Oncology Institute of Southern Switzerland, Via Ospedale 12, 6500, Bellinzona, Switzerland
| |
Collapse
|
4
|
Lang BHH, Woo YC, Wong IYH, Chiu KWH. Single-Session High-Intensity Focused Ultrasound Treatment for Persistent or Relapsed Graves Disease: Preliminary Experience in a Prospective Study. Radiology 2017; 285:1011-1022. [PMID: 28727542 DOI: 10.1148/radiol.2017162776] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Purpose To evaluate the safety and efficacy of ultrasonography (US)-guided high-intensity focused ultrasound (HIFU) ablation as a treatment for medically refractory Graves disease (GD). Materials and Methods After ethics approval, a prospective trial (NCT02685514) was performed from November 2015 to February 2016. Thirty patients underwent ablation of the entire right and left thyroid lobes, with areas near the tracheal-esophageal groove and common carotid artery left unablated. Serum thyroid-stimulating hormone (TSH), free T4 (FT4), antithyroid autoantibodies, and TSH receptor (TSHR) antibody levels were evaluated afterward, and US color Doppler, US volumetry, and eye assessment were performed. The primary outcome was the 12-month relapse rate. Relapse referred to hyperthyroidism (FT4 > 23 pmol/L) afterward. Variables associated with relapse were analyzed by using binary logistic regression. Results The technical success rate was 96.7%. The cohort comprised entirely women, with a median age of 38.2 years (interquartile range, 29.5-49.0 years). After 12 months, eight patients (26.7%; 95% confidence interval [CI]: 14.19%, 44.95%) experienced relapse. One patient (3.3%; 95% CI: 0.59%, 16.67%) experienced vocal cord palsy, while two patients (6.7%; 95% CI: 1.85%, 21.33%) experienced Horner syndrome, but none of these conditions were permanent. No changes in gland volume, antithyroid autoantibody levels, and ophthalmic parameters were found at 12-month follow-up. Baseline TSHR was found to have decreased significantly at 6- and 12-month follow-up (P < .001 for both). TSHR antibody (odds ratio [OR] = 1.414; 95% CI: 1.018, 1.965; P = .039) and gland volume (OR = 0.557; 95% CI: 0.353, 0.880; P = .012) were associated with 12-month relapse, with higher antibody levels conferring a higher likelihood and smaller gland volumes conferring a lower likelihood. Conclusion US-guided HIFU of the thyroid may be a safe and efficacious treatment in patients with persistent or relapsed GD. However, further study is warranted before it can become mainstream for this indication. © RSNA, 2017 Online supplemental material is available for this article.
Collapse
Affiliation(s)
- Brian Hung-Hin Lang
- From the Departments of Surgery (B.H.H.L.), Medicine (Y.C.W.), Ophthalmology (I.Y.H.W.), and Radiology (K.W.H.C.), The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong Special Administrative Region, China
| | - Yu-Cho Woo
- From the Departments of Surgery (B.H.H.L.), Medicine (Y.C.W.), Ophthalmology (I.Y.H.W.), and Radiology (K.W.H.C.), The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong Special Administrative Region, China
| | - Ian Yat-Hin Wong
- From the Departments of Surgery (B.H.H.L.), Medicine (Y.C.W.), Ophthalmology (I.Y.H.W.), and Radiology (K.W.H.C.), The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong Special Administrative Region, China
| | - Keith Wan-Hang Chiu
- From the Departments of Surgery (B.H.H.L.), Medicine (Y.C.W.), Ophthalmology (I.Y.H.W.), and Radiology (K.W.H.C.), The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong Special Administrative Region, China
| |
Collapse
|
5
|
Lang BHH, Wu ALH. High intensity focused ultrasound (HIFU) ablation of benign thyroid nodules - a systematic review. J Ther Ultrasound 2017; 5:11. [PMID: 28523127 PMCID: PMC5434558 DOI: 10.1186/s40349-017-0091-1] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2017] [Accepted: 02/09/2017] [Indexed: 12/13/2022] Open
Abstract
Background With an increasing number of imaging studies being done nowadays, the number of incidentally discovered thyroid nodules is expected to rise. Although many of these nodules are small and benign in nature, some do grow and may cause pressure and/or thyrotoxic symptoms. Surgical resection has traditionally been recommended for symptomatic nodules but is associated with risk of hypothyroidism, bleeding, infection, and nerve damage. High intensity focused ultrasound (HIFU) is one of the non-surgical thermal ablation techniques that may serve as an alternative in the treatment of benign thyroid nodules. The present review is to systematically evaluate the efficacy and safety of HIFU ablation. Methods We comprehensively searched all studies that evaluated the use of HIFU ablation as a treatment of benign thyroid nodules from Medline (PubMed) and Cochrane Library electronic databases using specific keywords. All titles identified by the search strategy were independently screened by two authors. Case reports, animal studies, editorials, expert opinions, reviews without original data and studies on pediatric population were excluded. Multiple reports of the same dataset were assessed and the most representative and updated report of a study was included. Results Five original studies were found. All treated thyroid nodules were confirmed to be benign cytologically and either appeared solid or predominantly (>70%) solid on ultrasonography. Only one type of commercially available US-guided device with an extracorporeal probe (3 MHz) was used in all the reported treatments. No major complications including recurrent laryngeal nerve injury, skin burn or haematoma were reported in all of the studies. The overall nodule volume reduction after single session of HIFU ablation ranged between 45 and 68%, depending on nodule size and length of follow-up. Conclusions Despite the few number of studies, our review appeared to suggest that HIFU is a safe and efficacious method of treating symptomatic benign thyroid nodules. However, larger-scale, prospective trials with longer follow-up period are indeed required to confirm this. In terms of the ablation itself, relative to other ablation techniques, there are still much room for improvements in shortening treatment duration and expanding the range of treatable nodules.
Collapse
Affiliation(s)
- Brian Hung-Hin Lang
- Department of Surgery, The University of Hong Kong, Hong Kong, SAR China.,Department of Surgery, Division of Endocrine Surgery, Queen Mary Hospital, 102 Pokfulam Road, Hong Kong, SAR China
| | - Arnold L H Wu
- Department of Surgery, The University of Hong Kong, Hong Kong, SAR China
| |
Collapse
|
6
|
Lang BHH, Woo YC, Wong CKH. High-Intensity Focused Ultrasound for Treatment of Symptomatic Benign Thyroid Nodules: A Prospective Study. Radiology 2017; 284:897-906. [PMID: 28419814 DOI: 10.1148/radiol.2017161640] [Citation(s) in RCA: 49] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Purpose To evaluate first-year efficacy and changes in pressure symptoms and health-related quality of life (HRQOL) after ultrasonographically (US) guided high-intensity focused ultrasound (HIFU) ablation of symptomatic benign thyroid nodules. Materials and Methods After ethics approval and informed consent were obtained, a prospective trial was conducted. Patients with a symptomatic benign thyroid nodule were given a choice of HIFU treatment or active surveillance. Clinical and US examinations, pressure symptom scores (visual analog scale), and HRQOL questionnaires (short form-12 survey) were evaluated at baseline and at 3, 6, and 12 months. The primary outcome was change in nodule volume after 12 months. The percentage of change in nodule volume was defined as the baseline volume minus the volume at 12 months divided by the baseline volume times 100. Ablation success was defined as a reduction in volume of greater than 50%. Nodule volume was compared by using the paired t test. Continuous variables were compared by using the Mann-Whitney U test, and categorical variables were compared by using χ2 tests. Results Twenty-two patients underwent HIFU and 22 underwent active surveillance. Mean age was 53.11 years (range, 28-76 years) and 55.19 years (range, 41-70 years), respectively. The ratio of men to women was 2:20 and 1:21, respectively. The 12-month mean volume reduction ± standard deviation in the HIFU group was significant (68.87% ± 15.27 [range, 47.35%-94.89%], P < .001) but not in the surveillance group (-2.11% ± 6.29 [range, -15.64% to 12.70%], P > .05). Preablation nodule volume was the only determinant of ablation success (odds ratio, 1.877; 95% confidence interval [CI]: 1.085, 3.249; P = .024). At 12 months, patients in the HIFU group had less swelling (P < .001), lower pressure symptom scores (P < .001), and higher physical composite scores (P = .006). Physical composite scores significantly correlated with 6-month reduction in nodule size (r = 0.768; 95% CI: 0.660, 0.930; P < .001) and 12-month reduction in nodule size (r = 0.704; 95% CI: 0.680, 940; P < .001). Conclusion HIFU ablation of symptomatic benign thyroid nodules not only induced significant shrinkage but also improved pressure symptom scores and HRQOL throughout a 12-month period. © RSNA, 2017.
Collapse
Affiliation(s)
- Brian Hung-Hin Lang
- From the Departments of Surgery (B.H.H.L.), Medicine (Y.C.W.), and Family Medicine and Primary Care (C.K.H.W.), The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Rd, Hong Kong SAR, China
| | - Yu-Cho Woo
- From the Departments of Surgery (B.H.H.L.), Medicine (Y.C.W.), and Family Medicine and Primary Care (C.K.H.W.), The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Rd, Hong Kong SAR, China
| | - Carlos K H Wong
- From the Departments of Surgery (B.H.H.L.), Medicine (Y.C.W.), and Family Medicine and Primary Care (C.K.H.W.), The University of Hong Kong, Queen Mary Hospital, 102 Pokfulam Rd, Hong Kong SAR, China
| |
Collapse
|
7
|
Ellens NPK, Partanen A. Preclinical MRI-Guided Focused Ultrasound: A Review of Systems and Current Practices. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2017; 64:291-305. [PMID: 27662675 DOI: 10.1109/tuffc.2016.2609238] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Effective preclinical research is a vital component in the development of MRI-guided focused ultrasound (MRgFUS) and its translation to clinic. In this review, we seek to outline the challenges at hand for effective preclinical research, survey different solutions, and underline best practices. Furthermore, we summarize efforts to build and characterize dedicated preclinical MRgFUS equipment, including lab prototypes and available commercial products. Finally, we discuss constraints and considerations specific to using clinical MRgFUS equipment in preclinical research. Specifically, we examine additional hardware that has been used to adapt clinical MRgFUS equipment to better position, constrain, and image preclinical subjects, as well as software solutions that have been used to extend the potential and capabilities of clinical devices.
Collapse
|
8
|
Mainini AP, Monaco C, Pescatori LC, De Angelis C, Sardanelli F, Sconfienza LM, Mauri G. Image-guided thermal ablation of benign thyroid nodules. J Ultrasound 2016; 20:11-22. [PMID: 28298940 DOI: 10.1007/s40477-016-0221-6] [Citation(s) in RCA: 81] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2016] [Accepted: 08/22/2016] [Indexed: 12/22/2022] Open
Abstract
Benign thyroid nodules are a common disease in the general population. Most often, they are completely asymptomatic and discovered occasionally during routine ultrasound examinations, and do not require any treatment. When thyroid nodules become symptomatic, surgical excision is still considered standard treatment. In the last few years, several experiences in the treatment of benign thyroid nodules through image-guided percutaneous thermal ablation have been reported with encouraging results, so that currently, these treatments are often proposed as first-choice options for patients with symptomatic benign thyroid nodules. In this paper, we discuss the present literature on the topic, focusing on different techniques available for image-guided percutaneous ablation, particularly radiofrequency (RFA), laser (LA), microwave (MWA), and high-intensity-focus ultrasound (HIFU). Little evidence about the efficacy of MWA and HIFU is now available. According to the literature, good results have been obtained with RFA and LA. Regarding RFA, volume reduction after ablative treatment has been found to range from 47 to 84 % at 3-6 months, and from 62 to 93 % at 1 year; LA also seems to be effective in achieving shrinkage of thyroid nodules, with volume reduction from 37 to 81 % at 3-6 months, and from 13 to 82 % at 1-year follow-up. Moreover, applications of advanced image-guidance modality, such as contrast-enhanced ultrasound and virtual navigation with fusion imaging, are discussed.
Collapse
Affiliation(s)
- Anna Pisani Mainini
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy
| | - Cristian Monaco
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy
| | - Lorenzo Carlo Pescatori
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy
| | - Chiara De Angelis
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122 Milan, Italy
| | - Francesco Sardanelli
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20100 Milan, Italy.,Unità di Radiologia, IRCCS Policlinico San Donato, Via Morandi 30, San Donato Milanese, 20097 Milan, Italy
| | - Luca Maria Sconfienza
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20100 Milan, Italy.,Radiologia/Diagnostica per immagini con servizio di radiologia Interventistica, IRCCS Istituto Ortopedico Galeazzi, via Riccardo Galeazzi 4, 20161 Milan, Italy
| | - Giovanni Mauri
- Dipartimento di Radiologia Interventistica, Istituto Europeo di Oncologia, Via Ripamonti 435, 20100 Milan, Italy
| |
Collapse
|
9
|
Kovatcheva RD, Vlahov JD, Stoinov JI, Zaletel K. Benign Solid Thyroid Nodules: US-guided High-Intensity Focused Ultrasound Ablation—Initial Clinical Outcomes. Radiology 2015; 276:597-605. [DOI: 10.1148/radiol.15141492] [Citation(s) in RCA: 64] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
|
10
|
Korkusuz H, Fehre N, Sennert M, Happel C, Grünwald F. Volume reduction of benign thyroid nodules 3 months after a single treatment with high-intensity focused ultrasound (HIFU). J Ther Ultrasound 2015; 3:4. [PMID: 25763185 PMCID: PMC4355001 DOI: 10.1186/s40349-015-0024-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2014] [Accepted: 01/06/2015] [Indexed: 01/06/2023] Open
Abstract
Background High-intensity focused ultrasound (HIFU) is a promising, non-invasive technique in treating benign thyroid nodules (TNs). The aim of this study was to evaluate the efficacy of HIFU to induce clinically meaningful shrinkage in benign predominantly solid TNs and to identify variables that influence or predict the magnitude of TN volume reduction. Methods For each of ten subjects, HIFU treatment was conducted on a single nodule. Nodular volume was measured sonographically at baseline and at 3 months post-procedure. Nodular function and early treatment assessment was done scintigraphically. Results Median nodular volume reduction was 0.7 ml absolute and 48.8% relative to pre-interventional size (p < 0.05). Absolute shrinkage was negatively correlated with the average treatment depth (τ = −0.61, p < 0.05). Absolute nodular volume was positively correlated with the scintigraphic nodular uptake reduction (τ = 0.66, p < 0.05). Conclusions HIFU treatment of benign predominantly solid TNs appears to be safe and effective for inducing nodular shrinkage. Despite potential for improvement, a single treatment session with HIFU is already a viable alternative to more standard methods. The feasibility of multiple HIFU treatments requires further investigation. Due to the small sample size, the findings of this analysis need conformation by larger studies.
Collapse
Affiliation(s)
- Huedayi Korkusuz
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.,German Center for Thermoablation of Thyroid Nodules (Deutsches Zentrum für Thermoablation von Schilddrüsenknoten), 60590 Frankfurt am Main, Germany
| | - Niklas Fehre
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Michael Sennert
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Christian Happel
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.,German Center for Thermoablation of Thyroid Nodules (Deutsches Zentrum für Thermoablation von Schilddrüsenknoten), 60590 Frankfurt am Main, Germany
| | - Frank Grünwald
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany.,German Center for Thermoablation of Thyroid Nodules (Deutsches Zentrum für Thermoablation von Schilddrüsenknoten), 60590 Frankfurt am Main, Germany
| |
Collapse
|
11
|
Kovatcheva R, Guglielmina JN, Abehsera M, Boulanger L, Laurent N, Poncelet E. Ultrasound-guided high-intensity focused ultrasound treatment of breast fibroadenoma-a multicenter experience. J Ther Ultrasound 2015; 3:1. [PMID: 25635224 PMCID: PMC4310188 DOI: 10.1186/s40349-014-0022-3] [Citation(s) in RCA: 54] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2014] [Accepted: 12/08/2014] [Indexed: 01/20/2023] Open
Abstract
Background The aim of our multicenter study was to assess the clinical outcome and safety of ultrasound (US)-guided high-intensity focused ultrasound (HIFU) in patients with breast fibroadenoma (FA). Methods From May 2011 to February 2013, 42 women with 51 FA in one or both breasts were selected for treatment with US-guided HIFU. Eight of 51 FA were treated twice. Patients’ age ranged from 16 to 52 years (mean 32 years). All patients with FA underwent core needle biopsy with histological confirmation. HIFU treatment was performed as an outpatient procedure under conscious sedation. Exclusion criteria were pregnant or lactating women, microcalcifications within the lesion at mammogram, history of breast cancer, previous laser or radiation therapy, and breast implant in the same breast. All patients signed written informed consent. After the treatment, follow-up US with volume evaluation was performed at 2, 6, and 12 months. Results The FA mean baseline volume was 3.89 ml (0.34–19.66 ml). At 2-month follow-up, the mean volume reduction was 33.2% ± 19.1% and achieved significance at 6-month (59.2% ± 18.2%, p < 0.001) and 12-month (72.5% ± 16.7%, p < 0.001) follow-up. Related side effects as superficial skin burn with blister-like aspect in three patients and hyperpigmentation over the treated area in one patient were transient and resolved spontaneously. In one patient, asymptomatic subcutaneous induration persisted at the end of the study. Conclusions US-guided HIFU treatment is an effective noninvasive method for the treatment of breast FA and well tolerated by the patients. Preliminary results are encouraging and show that HIFU could be an alternative to surgery for breast FA.
Collapse
Affiliation(s)
- Roussanka Kovatcheva
- Department of Thyroid and Metabolic Bone Disorders, University Hospital of Endocrinology, Medical University of Sofia, 2 Zdrave Street, 1431 Sofia, Bulgaria
| | - Jean-Noël Guglielmina
- Department of Gynecological Surgery, American Hospital of Paris, 63 Bld Victor Hugo, 92200 Neuilly-sur-Seine, France
| | - Marc Abehsera
- Department of Medical Imaging, American Hospital of Paris, 63 Bld Victor Hugo, 92200 Neuilly-sur-Seine, France
| | - Loïc Boulanger
- Department of Gynecological and Breast Surgery, University Hospital of Lille, Ave Eugène Avinée, 59037 Lille, France
| | - Nicolas Laurent
- Department of Imaging, Regional Hospital of Valenciennes, Ave Désandrouin - BP 479, 59322 Valenciennes, France
| | - Edouard Poncelet
- Department of Imaging, Regional Hospital of Valenciennes, Ave Désandrouin - BP 479, 59322 Valenciennes, France
| |
Collapse
|
12
|
Korkusuz H, Sennert M, Fehre N, Happel C, Grünwald F. Local thyroid tissue ablation by high-intensity focused ultrasound: effects on thyroid function and first human feasibility study with hot and cold thyroid nodules. Int J Hyperthermia 2014; 30:480-5. [PMID: 25313977 DOI: 10.3109/02656736.2014.962626] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
OBJECTIVE The aim of this study was to assess whether high-intensity focused ultrasound (HIFU), a new and promising method for the treatment of benign hot and cold thyroid nodules using thermal ablation, has an impact on thyroid function, and to evaluate its feasibility in outpatient settings. Additionally, a possible difference in the treatment of solid and complex thyroid nodules was evaluated. METHOD Ten patients with one thyroid nodule each (six cold and four hot nodules) underwent HIFU in January 2014. Four nodules were solid and six nodules were complex. Serum levels of triiodothyronine (T3), thyroxine (T4), thyrotropin (TSH), thyroglobulin (hTg) and additionally antibodies against hTg (TAK), TSH receptors (TRAK) and thyroid peroxidase (TPO) were measured at enrolment and 24 h after the HIFU treatment. The pre- and post-thyroglobulin reduction was measured to evaluate the scale of ablation. In addition, patients' pain was recorded on a numeric rating scale from 0 to 10. RESULTS The HIFU treatment did not affect thyroid function, since hormone levels stayed stable (p < 0.05). No serious immune reaction was induced. Thyroglobulin serum levels increased significantly (p < 0.05) and were correlated to the total energy emitted by HIFU (p < 0.1). The results of complex thyroid nodules did not differ from solid thyroid nodules. Similarly, the results of hot thyroid nodules did not differ from cold thyroid nodules. All patients tolerated the whole treatment and no severe complications were observed. CONCLUSION HIFU is a safe and effective method to treat benign, solid, complex, hot and cold thyroid nodules preserving thyroid function. Further developments of the system are needed to gain suitability for daily use.
Collapse
Affiliation(s)
- Hüdayi Korkusuz
- Department of Nuclear Medicine, University Hospital Frankfurt , Frankfurt am Main , Germany
| | | | | | | | | |
Collapse
|
13
|
Korkusuz H, Fehre N, Sennert M, Happel C, Grünwald F. Early assessment of high-intensity focused ultrasound treatment of benign thyroid nodules by scintigraphic means. J Ther Ultrasound 2014; 2:18. [PMID: 25276352 PMCID: PMC4179864 DOI: 10.1186/2050-5736-2-18] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2014] [Accepted: 09/03/2014] [Indexed: 12/16/2022] Open
Abstract
Background High-intensity focused ultrasound (HIFU) allows to inflict intracorporal thermal lesions without penetrating the skin or damaging the surrounding tissue. This analysis intends to assess the magnitude of HIFU-induced ablations within benign thyroid nodules using scintigraphic imaging with 99mTc. Methods Ten cold, hot, or indifferent nodules were treated using multiple pulses of HIFU to induce temperatures of around 85°C within the ablation zone. Pre- and posttreatment, uptake values of 99mTc-pertechnetate or 99mTc-MIBI were recorded. The pre-post reduction of nodular uptake was evaluated to assess ablation magnitude. Results Relative nodular uptake in relation to total thyroidal uptake decreased after one session of HIFU in all cases. Median 99mTc-MIBI uptake reduction was 35.5% (ranging from 11% to 57%; p < 0.1), while 99mTc-pertechnetate scintigraphy showed a median uptake reduction of 27% (range 10% to 44%; p < 0.1). No major complications were observed. Conclusions HIFU appears to be safe and is an easy to perform means of thermal ablation. This study shows that HIFU treatment in thyroidal nodules can be evaluated by scintigraphic means shortly after the intervention. Due to small sample size, the exact magnitude of HIFU ablation efficiency in thyroidal nodules remains a value to be assessed in a larger study.
Collapse
Affiliation(s)
- Huedayi Korkusuz
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Niklas Fehre
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Michael Sennert
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Christian Happel
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| | - Frank Grünwald
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, 60590 Frankfurt am Main, Germany
| |
Collapse
|
14
|
Chen D, Xia R, Corry PM, Moros EG, Shafirstein G. SonoKnife for ablation of neck tissue: in vivo verification of a computer layered medium model. Int J Hyperthermia 2012; 28:698-705. [PMID: 22946601 DOI: 10.3109/02656736.2012.706730] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE This study aimed to determine which treatment parameters of the SonoKnife device can be used to safely and effectively perform non-invasive thermal ablation of subcutaneous tissue. METHODS A three-dimensional computational layered medium model was constructed to simulate thermal ablation treatment of the SonoKnife device. The acoustic and thermal fields were calculated with the Fast Object-Oriented C++ Ultrasound-Simulator software and a finite difference code, respectively. Subcutaneous tissue was represented as layers of skin, fat and muscle. The simulations were conducted for ultrasound frequencies of 1 or 3.5 MHz. The thermal dose model was used to predict the size and location of the ablated regions. The computer simulations were verified by using the SonoKnife to perform subcutaneous ablations in the neck area of healthy pigs, in vivo. Triphenyltetrazolium chloride viability stain was used to differentiate viable tissue from ablated regions ex vivo. RESULTS The simulations for the layered medium model suggest that operating the SonoKnife at frequency of 1 MHz is more effective and safer than 3.5 MHz providing skin cooling is applied prior to ablation. These predictions were in agreement with the results observed in the animal studies. The required sonication time for ablation increased from 50 to 300 s by using 1 MHz. CONCLUSION Our modelling and animal studies suggest that 1 MHz with pretreatment skin cooling are the optimal settings to operate the SonoKnife to safely and effectively perform subcutaneous thermal ablation of porcine skin. More work is needed to optimise skin cooling and define the optimal sonication time.
Collapse
Affiliation(s)
- Duo Chen
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas, USA
| | | | | | | | | |
Collapse
|
15
|
Fan Z, Luo W, Song Z, Zheng W, Hu H, Du L, Zhou X. Effect of healthy tissue ablation surrounding VX2 rabbit liver tumors by high-intensity focused ultrasound combined with an ultrasound contrast agent. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2012; 31:863-871. [PMID: 22644682 DOI: 10.7863/jum.2012.31.6.863] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
OBJECTIVES The purpose of this study was to determine the minimum amount of healthy peripheral tissue that should be ablated when treating VX2 liver tumors with high-intensity focused ultrasound combined with an ultrasound contrast agent. METHODS Fifty-one rabbits with hepatic tumors were established and randomly divided into the following groups: group A, which only had their tumors ablated; group B, which had their tumors and 2 mm of healthy adjacent tissue ablated; and group C, which had their tumors and 4 mm of healthy adjacent tissue ablated. The pathologic characteristics of the target tissue, serum alanine aminotransferase (ALT) level, presence of intrahepatic and distant metastases, and survival time between different groups were compared after high-intensity focused ultrasound treatment. RESULTS After ablation, coagulative necrosis was observed in all targeted tissue. The serum ALT level in group C was the highest and the level in group A was the lowest on the third and fifth days after ablation (P < .05), respectively. Fourteen days later, the serum ALT level in groups B and C decreased to normal, whereas the level in group A was abnormal and significantly higher (P < .05). Compared with group A, the prevalence of metastases in groups B and C was significantly lower (P < .05), and the survival time was significantly longer (P < .05); there appeared to be no statistically significant difference between groups B and C (P > .05). CONCLUSIONS Ablation of a tumor along with 2 mm of healthy surrounding tissue is a more effective strategy for treating hepatic cancer with high-intensity focused ultrasound coupled with an ultrasound contrast agent.
Collapse
Affiliation(s)
- Zhiyong Fan
- Department of Hepatobiliary Surgery, Shaanxi Provincial People’s Hospital, Xi’an, China
| | | | | | | | | | | | | |
Collapse
|
16
|
Chen D, Xia R, Chen X, Shafirstein G, Corry PM, Griffin RJ, Penagaricano JA, Tulunay-Ugur OE, Moros EG. SonoKnife: feasibility of a line-focused ultrasound device for thermal ablation therapy. Med Phys 2011; 38:4372-85. [PMID: 21859038 DOI: 10.1118/1.3601017] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
Abstract
PURPOSE To evaluate the feasibility of line-focused ultrasound for thermal ablation of superficially located tumors. METHODS A SonoKnife is a cylindrical-section ultrasound transducer designed to radiate from its concave surface. This geometry generates a line-focus or acoustic edge. The motivation for this approach was the noninvasive thermal ablation of advanced head and neck tumors and positive neck nodes in reasonable treatment times. Line-focusing may offer advantages over the common point-focusing of spherically curved radiators such as faster coverage of a target volume by scanning of the acoustic edge. In this paper, The authors report studies using numerical models and phantom and ex vivo experiments using a SonoKnife prototype. RESULTS Acoustic edges were generated by cylindrical-section single-element ultrasound transducers numerically, and by the prototype experimentally. Numerically, simulations were performed to characterize the acoustic edge for basic design parameters: transducer dimensions, line-focus depth, frequency, and coupling thickness. The dimensions of the acoustic edge as a function of these parameters were determined. In addition, a step-scanning simulation produced a large thermal lesion in a reasonable treatment time. Experimentally, pressure distributions measured in degassed water agreed well with acoustic simulations, and sonication experiments in gel phantoms and ex vivo porcine liver samples produced lesions similar to those predicted with acoustic and thermal models. CONCLUSIONS Results support the feasibility of noninvasive thermal ablation with a SonoKnife.
Collapse
Affiliation(s)
- Duo Chen
- Department of Radiation Oncology, University of Arkansas for Medical Sciences, Little Rock, Arkansas 72205, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Esnault O, Franc B, Ménégaux F, Rouxel A, De Kerviler E, Bourrier P, Lacoste F, Chapelon JY, Leenhardt L. High-intensity focused ultrasound ablation of thyroid nodules: first human feasibility study. Thyroid 2011; 21:965-73. [PMID: 21834683 DOI: 10.1089/thy.2011.0141] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Thyroid surgery is common, but complications may occur. High-intensity focused ultrasound (HIFU) is a minimally invasive alternative to surgery. We hypothesized that an optimized HIFU device could be safe and effective for ablating benign thyroid nodules without affecting neighboring structures. METHODS In this open, single-center feasibility study, 25 patients were treated with HIFU with real-time ultrasound imaging 2 weeks before a scheduled thyroidectomy for multinodular goiter. Thyroid ultrasonography imaging, thyroid function, were evaluated before and after treatment. Adverse events were carefully recorded. Each patient received HIFU for one thyroid nodule, solid or mixed, with mean diameter ≥8 mm, and no suspicion of malignancy. The HIFU device was progressively adjusted with stepwise testing. The energy level for ablation ranged from 35 to 94 J/pulse for different groups of patients. One pathologist examined all removed thyroids. RESULTS Three patients discontinued treatment due to pain or skin microblister. Among the remaining 22 patients, 16 showed significant changes by ultrasound. Macroscopic and histological examinations showed that all lesions were confined to the targeted nodule without affecting neighboring structures. At pathological analysis, the extent of nodule destruction ranged from 2% to 80%. Five out of 22 patients had over 20% pathological lesions unmistakably attributed to HIFU. Seventeen cases had putative lesions including nonspecific necrosis, hemorrhage, nodule detachment, cavitations, and cysts. Among these 17 cases, 12 had both ultrasound changes and cavitation at histology that may be expected for an HIFU effect. In the last three patients ablated at the highest energy level, significant ultrasound changes and complete coagulative necrosis were observed in 80%, 78%, and 58% of the targeted area, respectively. There were no major complications of ablation. CONCLUSION This study showed the potential efficacy of HIFU for human thyroid nodule ablation. Lesions were clearly visible by histology and ultrasound after high energy treatments, and safety and tolerability were good. We identified a power threshold for optimal necrosis of the target thyroid tissue. Further studies are ongoing to assess nodule changes at longer follow-up times.
Collapse
Affiliation(s)
- Olivier Esnault
- ENT & Cervicofacial Surgery (Private Practice), Paris, France.
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Guide de bonnes pratiques pour l’usage de l’échographie cervicale et des techniques écho-guidées dans la prise en charge des cancers thyroïdiens différenciés de souche vésiculaire. ANNALES D'ENDOCRINOLOGIE 2011; 72:H1-26. [DOI: 10.1016/s0003-4266(11)70001-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
19
|
Leenhardt L, Borson-Chazot F, Calzada M, Carnaille B, Charrié A, Cochand-Priollet B, Do Cao C, Leboulleux S, Le Clech G, Mansour G, Menegaux F, Monpeyssen H, Orgiazzi J, Rouxel A, Sadoul JL, Schlumberger M, Tramalloni J, Tranquart F, Wemeau JL. Good practice guide for cervical ultrasound scan and echo-guided techniques in treating differentiated thyroid cancer of vesicular origin. ANNALES D'ENDOCRINOLOGIE 2011; 72:173-97. [PMID: 21641577 DOI: 10.1016/j.ando.2011.04.001] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/04/2010] [Accepted: 02/05/2010] [Indexed: 12/30/2022]
Abstract
Good practice guide for cervical ultrasound scan and echo-guided techniques in treating differentiated thyroid cancer of vesicular origin. American, European and French Recommendations for the treatment of differentiated vesicular thyroid cancer were recently published. Cervical ultrasound scanning is now considered a key examination in the follow-up of these cancers. This examination is noninvasive, easy to perform and to obtain, is not costly, but remains operator-dependent. To date, there are no recommendations published that assemble all the technical aspects, results, indications and the limits of this examination in the initial medical report and the follow-up of these cancers. In order to standardise the procedure and validate the quality of the examination, a workgroup made up of a panel of experts particularly involved in carrying out ultrasound scans was set up. The aim was to draw up a good practice guide for performing cervical ultrasound scans and echo-guided techniques in treating patients with differentiated thyroid cancer of vesicular origin. The main objectives are to: (a) standardise the procedure and reports, (b) define the criteria for establishing whether lesions identified during a cervical ultrasound scan are malignant or benign, (c) standardise the indications for carrying out cytological tests and an in situ assay of markers, (d) help doctors to select the patients who ought to receive a cervical ultrasound scan and or cytological tests, (e) discuss how frequently the examinations should be carried out depending on the risk of recurrence.
Collapse
Affiliation(s)
- L Leenhardt
- Department of Nuclear Medicine, Pitié Salpêtrière Hospital, Paris cedex, France.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Haller J, Wilkens V, Jenderka KV, Koch C. Characterization of a fiber-optic displacement sensor for measurements in high-intensity focused ultrasound fields. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 129:3676-3681. [PMID: 21682392 DOI: 10.1121/1.3583538] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A fiber-optic sensor is presented that is capable of measuring the particle displacement in high-intensity focused ultrasound (HIFU) fields. For this probe, a secondary calibration was performed, and the resulting complex frequency response is discussed. As a first practical application, the setup was used to measure the pressure in the field of a weakly focusing ultrasound transducer. The result is compared with that of a membrane hydrophone measurement. The feasibility of measurements in HIFU fields is demonstrated by means of measurements of the spatial distribution of the peak particle velocity within the focus of a HIFU transducer and of the dependence of the peak values on the acoustical power level.
Collapse
Affiliation(s)
- Julian Haller
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany.
| | | | | | | |
Collapse
|
21
|
Valcavi R, Riganti F, Bertani A, Formisano D, Pacella CM. Percutaneous laser ablation of cold benign thyroid nodules: a 3-year follow-up study in 122 patients. Thyroid 2010; 20:1253-61. [PMID: 20929405 DOI: 10.1089/thy.2010.0189] [Citation(s) in RCA: 175] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
BACKGROUND Percutaneous laser ablation (PLA) is a proposed therapeutic procedure for the management of benign thyroid nodules. However, long-term results are unknown. The aim of this study was to evaluate retrospectively the safety and effects of PLA treatment in patients with benign nonfunctioning thyroid nodules in a 3-year follow-up. METHODS One hundred twenty-two patients (95 women and 27 men; age 52.2 ± 12.3 years) with benign cold thyroid solitary nodules or a dominant nodule within a normo-functioning multinodular goiter (volume range: 2.6-86.4 mL) underwent thermal Nd:YAG laser ablation of thyroid nodular tissue by 1-4 optical fibers positioned into the tissue by 21-gauge needles under ultrasound real-time assistance. The setting was an interventional suite and outpatient endocrine clinics in a community hospital in Italy. Nodule volume, ablation volume, side effects, serum thyroid-stimulating hormone (TSH), free triiodothyronine, free thyroxine (fT4), thyroglobulin (Tg), anti-Tg, anti-thyroperoxidase antibodies, symptoms, and cosmetic signs were recorded. RESULTS Data are mean ± standard deviation. Energy delivered was 8522 ± 5365 J with an output power of 3.1 ± 0.5 W. Three years after PLA, nodule volume decreased from 23.1 ± 21.3 to 12.5 ± 18.8 mL (-47.8% ± 33.1% of initial volume, p ≤ 0.001). At day 1, TSH and fT4 values significantly changed (time 0 vs. day 1: TSH = 1.16 ± 1.06 vs. 0.62 ± 0.81 μU/mL, p ≤ 0.001; fT4 = 11.68 ± 1.88 vs. 13.20 ± 3.32 pg/mL, p ≤ 0.01) and normalized within 1 month. No change in free triiodothyronine, thyroperoxidase antibodies, and Tg antibodies values was observed. Symptoms improved in 89 patients (73.0%), were unchanged in 28 (22.9%), and worsened in 5 (4.1%). Cosmetic signs improved in 87 patients (71.3%), were unchanged in 29 (23.8%), and worsened in 6 (4.9%). In 11 patients (9%), nodules regrew above baseline. Two patients (1.6%) experienced delayed (12-24 hours) laryngeal dysfunction with vocal cord motility recovery after 6-10 weeks. Two patients (1.6%) became hypothyroid and two patients (1.6%) hyperthyroid after PLA. CONCLUSIONS After 3 years, the PLA technique achieved shrinkage of about 50% of the initial volume in a wide size range of benign cold thyroid nodules, with an improvement in local symptoms and signs. Side effects and failures were few although not negligible. PLA may be a new option for the management of benign cold thyroid nodules. Long-term controlled studies are required to establish the eligibility of patients for routine PLA.
Collapse
Affiliation(s)
- Roberto Valcavi
- Endocrinology Division and Thyroid Disease Center, Arcispedale Santa Maria Nuova, Reggio Emilia, Italy.
| | | | | | | | | |
Collapse
|
22
|
High-intensity focused ultrasound to treat primary hyperparathyroidism: a feasibility study in four patients. AJR Am J Roentgenol 2010; 195:830-5. [PMID: 20858805 DOI: 10.2214/ajr.09.3932] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE Many patients with primary hyperparathyroidism either decline or are not candidates for surgical parathyroidectomy. There are drawbacks to medical therapy as well as percutaneous ethanol injection as alternative therapies for primary hyperparathyroidism. Therefore, in this pilot study, our aim was to test the feasibility, safety, and efficacy of a newly developed noninvasive high-intensity focused ultrasound (HIFU) technique for the nonsurgical management of primary hyperparathyroidism. SUBJECTS AND METHODS We treated four menopausal women with biochemical, sonographic, and cytologic evidence of benign primary hyperparathyroidism. HIFU treatment was performed in two sessions using TH-One under sonographic guidance and with the patient under conscious sedation. Parathyroid volume and function were evaluated at baseline and repeatedly until 12 months after the second HIFU session. RESULTS Serum parathyroid hormone levels decreased in all four patients and normalized 1 and 8 months after the second HIFU session in two patients. Serum calcium levels decreased in all patients and normalized in three patients. Three of four parathyroid tumors had decreased in size by 11%, 43%, and 79%, respectively, 12 months after the second HIFU session. All adverse events related to HIFU were transient: mild subcutaneous edema in three patients and impaired vocal cord mobility in one patient that resolved 40 days later. CONCLUSION HIFU is a promising procedure for patients with primary hyperparathyroidism that may become an alternative to established options, especially in elderly patients with comorbidities, or in patients who decline surgery. Large-scale long-term studies including patients with secondary and tertiary hyperparathyroidism are warranted.
Collapse
|