Lekx KS, deKemp RA, Beanlands RS, Wisenberg G, Wells RG, Stodilka RZ, Lortie M, Klein R, Zabel P, Kovacs MS, Sykes J, Prato FS. Quantification of regional myocardial blood flow in a canine model of stunned and infarcted myocardium: comparison of rubidium-82 positron emission tomography with microspheres.
Nucl Med Commun 2010;
31:67-74. [PMID:
19823095 DOI:
10.1097/MNM.0b013e328332b32a]
[Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND
Myocardial viability and quantification of regional myocardial blood flow (MBF) are important for the diagnosis of heart disease. Positron emission tomography is the current gold standard for determining myocardial viability, but most positron-emitting perfusion tracers require an on-site cyclotron. Rubidium-82 ((82)Rb) is a myocardial perfusion tracer that is produced using an on-site generator. This study investigates (82)Rb-measured MBF in canine models of stunned and infarcted myocardium compared with selected measurements obtained concurrently using microspheres.
METHODS
Myocardial stunning and infarction were created in canines by occluding the left anterior descending for 15 min and 2 h, respectively. Stunning was produced in all animals; six animals were reperfused after the 2 h occlusion, whereas the other six animals remained occluded permanently. Regional MBF was measured in each group during rest and dobutamine stress at acute and chronic (8 weeks postinsult) time points using dynamic (82)Rb perfusion imaging and radioactively labeled microspheres.
RESULTS
Average resting MBF with microspheres and Rb was 0.68+/-0.02 versus 0.73+/-0.01 (P<0.001) in nonischemic tissue, and 0.53+/-0.03 versus 0.42+/-0.02 (P<0.001) in the region-at-risk tissue, respectively. Average MBF during stress with microspheres and Rb was 2.78+/-0.15 versus 3.53+/-0.16 (P<0.05) in the nonischemic tissue, and 1.90+/-0.20 versus 2.31+/-0.26 (P = NS) in the region-at-risk tissue, respectively.
CONCLUSION
Despite the small significant differences, the dynamic (82)Rb measurements provide estimates of MBF in stunned and acutely and chronically infarcted tissue at rest and during hyperemia that correspond with clinical interpretation.