Aigner P, Sella Bart E, Panfili S, Körner T, Mach M, Andreas M, Königshofer M, Saitta S, Redaelli A, Schmid A, Moscato F. Quantification of paravalvular leaks associated with TAVI implants using 4D MRI in an aortic root phantom made possible by the use of 3D printing. Front Cardiovasc Med 2023; 10:1083300. [PMID: 36742071 PMCID: PMC9894656 DOI: 10.3389/fcvm.2023.1083300] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2022] [Accepted: 01/02/2023] [Indexed: 01/21/2023] Open
Abstract
Introduction Transcatheter aortic valve implantation (TAVI) has become an alternative to surgical replacement of the aortic valve elderly patients. However, TAVI patients may suffer from paravalvular leaks (PVL). Detecting and grading is usually done by echocardiography, but is limited by resolution, 2D visualization and operator dependency. 4D flow magnetic resonance imaging (MRI) is a promising alternative, which did not reach clinical application in TAVI patients. The aim of this study was applying 3D printing technologies in order to evaluate flow patterns and hemodynamics of PVLs following TAVI, exploiting 4D flow MRI and standard ultrasound. Materials and methods An MR-compatible, anatomically left ventricle, aortic root, and ascending aorta model was fabricated by combining 3D-printed parts and various soft silicone materials to match physiological characteristics. An Abbott Portico™ valve was used in continuous antegrade flow (12-22 l/min), retrograde flow with varying transvalvular pressures (60-110 mmHg), and physiological pulsatile hemodynamics (aortic pressure: 120/80 mmHg, cardiac output: 5 l/min) Time-resolved MR measurements were performed above and below the TAVI stent and compared with color Doppler ultrasound measurements in exactly the same setup. Results The continuous antegrade flow measurements from MRI largely agreed with the flowmeter measurements, and a maximum error of only 7% was observed. In the retrograde configuration, visualization of the paravalvular leaks was possible from the MR measurements, but flow was overestimated by up to 33%. The 4D MRI measurement in the pulsatile setup revealed a single main PVL, which was also confirmed by the color Doppler measurements, and velocities were similar (2.0 m/s vs. 1.7 m/s). Discussion 4D MRI techniques were used to qualitatively assess flow in a patient-specific, MR-compatible and flexible model, which only became possible through the use of 3D printing techniques. Flow patterns in the ascending aorta, identification and quantification of PVLs was possible and the location and extent of PVLs were confirmed by ultrasound measurements. The 4D MRI flow technique allowed evaluation of flow patterns in the ascending aorta and the left ventricle below the TAVI stent with good results in identifying PVLs, demonstrating its capabilities over ultrasound by providing the ability to visualize the paravalvular jets in three dimensions at however, additional expenditure of time and money.
Collapse
Affiliation(s)
- Philipp Aigner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria,*Correspondence: Philipp Aigner,
| | - Eleonora Sella Bart
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Sebastiano Panfili
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Tito Körner
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Markus Mach
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Martin Andreas
- Department of Cardiac Surgery, Medical University of Vienna, Vienna, Austria
| | - Markus Königshofer
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Simone Saitta
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Alberto Redaelli
- Department of Electronics, Information, and Bioengineering, Politecnico di Milano, Milan, Italy
| | - Albrecht Schmid
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
| | - Francesco Moscato
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria,Ludwig Boltzmann Institute for Cardiovascular Research, Vienna, Austria,Austrian Cluster for Tissue Regeneration, Vienna, Austria
| |
Collapse
|
2
|
Choe YH, Kim SM, Park SJ. Computed tomography and magnetic resonance imaging assessment of aortic valve stenosis: an update. PRECISION AND FUTURE MEDICINE 2020. [DOI: 10.23838/pfm.2020.00093] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023] Open
|
3
|
Randomised comparison of a balloon-expandable and self-expandable valve with quantitative assessment of aortic regurgitation using magnetic resonance imaging. Neth Heart J 2020; 28:253-265. [PMID: 32246266 PMCID: PMC7190770 DOI: 10.1007/s12471-020-01414-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022] Open
Abstract
Introduction Transcatheter aortic valve implantation (TAVI) is a safe and effective treatment for inoperable, intermediate- or high-risk patients with severe symptomatic aortic stenosis and has been associated with excellent clinical outcomes. A clinically relevant remaining problem is aortic regurgitation (AR) post-TAVI, which is associated with increased mortality. Therefore, we conducted a prospective randomised trial to assess the safety and efficacy of a first-generation self-expandable valve (SEV; CoreValve) and a third-generation balloon-expandable valve (BEV; Sapien 3) with respect to clinical outcomes and AR as determined quantitatively by magnetic resonance imaging (MRI). Methods The ELECT study was an investigator-initiated, single-centre trial involving patients with severe symptomatic aortic stenosis and with a clinical indication for transfemoral TAVI. Fifty-six patients were randomly assigned to the BEV or SEV group. Results AR determined quantitatively by MRI was lower in the BEV than in the SEV group [regurgitant fraction: 1.1% (0–8.0) vs 8.7% (3.0–14.8) for SEV; p = 0.01]. Secondary endpoints according to the criteria of the Second Valve Academic Research Consortium (VARC-2) showed BEV to have better early safety [0 (0%) vs 8 (30%); p = 0.002] at 30 days and a lower risk of stroke [0 (0%) vs 5 (21%); p = 0.01], major adverse cardiac and cerebrovascular events [0 (0%) vs 10 (38%); p < 0.001] or death [0 (0%) vs 5 (19%); p = 0.02] in the 1st year compared with SEV. Conclusions The use of the latest generation of BEV was associated with less AR as quantitatively assessed by MRI. Although the use of MRI to quantify AR is not feasible in daily clinical practice, it should be considered as a surrogate endpoint for clinical outcomes in comparative studies of valves for TAVI. ClinicalTrials.gov number NCT01982032.
Collapse
|
4
|
Mao W, Wang Q, Kodali S, Sun W. Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root. J Biomech Eng 2019; 140:2683660. [PMID: 30029247 DOI: 10.1115/1.4040457] [Citation(s) in RCA: 32] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2017] [Indexed: 11/08/2022]
Abstract
Paravalvular leak (PVL) is a relatively frequent complication after transcatheter aortic valve replacement (TAVR) with increased mortality. Currently, there is no effective method to pre-operatively predict and prevent PVL. In this study, we developed a computational model to predict the severity of PVL after TAVR. Nonlinear finite element (FE) method was used to simulate a self-expandable CoreValve deployment into a patient-specific aortic root, specified with human material properties of aortic tissues. Subsequently, computational fluid dynamics (CFD) simulations were performed using the post-TAVR geometries from the FE simulation, and a parametric investigation of the impact of the transcatheter aortic valve (TAV) skirt shape, TAV orientation, and deployment height on PVL was conducted. The predicted PVL was in good agreement with the echocardiography data. Due to the scallop shape of CoreValve skirt, the difference of PVL due to TAV orientation can be as large as 40%. Although the stent thickness is small compared to the aortic annulus size, we found that inappropriate modeling of it can lead to an underestimation of PVL up to 10 ml/beat. Moreover, the deployment height could significantly alter the extent and the distribution of regurgitant jets, which results in a change of leaking volume up to 70%. Further investigation in a large cohort of patients is warranted to verify the accuracy of our model. This study demonstrated that a rigorously developed patient-specific computational model can provide useful insights into underlying mechanisms causing PVL and potentially assist in pre-operative planning for TAVR to minimize PVL.
Collapse
Affiliation(s)
- Wenbin Mao
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30313-2412
| | - Qian Wang
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, GA 30313-2412
| | - Susheel Kodali
- Division of Cardiology, Columbia University Medical Center, New York 10032
| | - Wei Sun
- Tissue Mechanics Laboratory, The Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, 206 Technology Enterprise Park, Georgia Institute of Technology, 387 Technology Circle, Atlanta, GA 30313-2412 e-mail:
| |
Collapse
|
5
|
Kooistra NHM, Nijhoff F, Abawi M, Agostoni P, Araya Roos DM, van Tuijl S, Blanken N, Voskuil M, Doevendans PAFM, Stella PR, Leiner T. Ex Vivo Pilot Study of Cardiac Magnetic Resonance Velocity Mapping for Quantification of Aortic Regurgitation in a Porcine Model in the Presence of a Transcatheter Heart Valve. J Cardiovasc Transl Res 2019; 12:310-320. [PMID: 30877562 PMCID: PMC6708050 DOI: 10.1007/s12265-019-09878-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/09/2018] [Accepted: 02/22/2019] [Indexed: 11/02/2022]
Abstract
Accuracy of aortic regurgitation (AR) quantification by magnetic resonance (MR) imaging in the presence of a transcatheter heart valve (THV) remains to be established. We evaluated the accuracy of cardiac MR velocity mapping for quantification of antegrade flow (AF) and retrograde flow (RF) across a THV and the optimal slice position to use in cardiac MR imaging. In a systematic and fully controlled laboratory ex vivo setting, two THVs (Edwards SAPIEN XT, Medtronic CoreValve) were tested in a porcine model (n = 1) under steady flow conditions. Results showed a high level of accuracy and precision. For both THVs, AF was best measured at left ventricular outflow tract level, and RF at ascending aorta level. At these levels, MR had an excellent repeatability (ICC > 0.99), with a tendency to overestimate (4.6 ± 2.4% to 9.4 ± 7.0%). Quantification of AR by MR velocity mapping in the presence of a THV was accurate, precise, and repeatable in this pilot study, when corrected for the systematic error and when the best MR slice position was used. Confirmation of these results in future clinical studies would be a step forward in increasing the accuracy of the assessment of paravalvular AR severity.
Collapse
Affiliation(s)
- Nynke H M Kooistra
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Heidelberglaan 100, 3508 GA, Utrecht, The Netherlands
| | - Freek Nijhoff
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Heidelberglaan 100, 3508 GA, Utrecht, The Netherlands
| | - Masieh Abawi
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Heidelberglaan 100, 3508 GA, Utrecht, The Netherlands
| | - Pierfrancesco Agostoni
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Heidelberglaan 100, 3508 GA, Utrecht, The Netherlands.,Department of Cardiology, Hartcentrum ZNA Middelheim, Antwerp, Belgium
| | - Daniël M Araya Roos
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | | | - Niels Blanken
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Michiel Voskuil
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Heidelberglaan 100, 3508 GA, Utrecht, The Netherlands
| | - Pieter A F M Doevendans
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Heidelberglaan 100, 3508 GA, Utrecht, The Netherlands
| | - Pieter R Stella
- Department of Cardiology, University Medical Center Utrecht, Utrecht, Heidelberglaan 100, 3508 GA, Utrecht, The Netherlands.
| | - Tim Leiner
- Department of Radiology, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
6
|
Bollache E, Fedak PWM, van Ooij P, Rahman O, Malaisrie SC, McCarthy PM, Carr JC, Powell A, Collins JD, Markl M, Barker AJ. Perioperative evaluation of regional aortic wall shear stress patterns in patients undergoing aortic valve and/or proximal thoracic aortic replacement. J Thorac Cardiovasc Surg 2017; 155:2277-2286.e2. [PMID: 29248286 DOI: 10.1016/j.jtcvs.2017.11.007] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 10/11/2017] [Accepted: 11/06/2017] [Indexed: 10/18/2022]
Abstract
OBJECTIVES To assess in patients with aortopathy perioperative changes in thoracic aortic wall shear stress (WSS), which is known to affect arterial remodeling, and the effects of specific surgical interventions. METHODS Presurgical and postsurgical aortic 4D flow MRI were performed in 33 patients with aortopathy (54 ± 14 years; 5 women; sinus of Valsalva (d_SOV)/midascending aortic (d_MAA) diameters = 44 ± 5/45 ± 6 mm) scheduled for aortic valve (AVR) and/or root (ARR) replacement. Control patients with aortopathy who did not have surgery were matched for age, sex, body size, and d_MAA (n = 20: 52 ± 14 years; 3 women; d_SOV/d_MAA = 42 ± 4/42 ± 4 mm). Regional aortic 3D systolic peak WSS was calculated. An atlas of WSS normal values was used to quantify the percentage of at-risk tissue area with abnormally high WSS, excluding the area to be resected/graft. RESULTS Peak WSS and at-risk area showed low interobserver variability (≤0.09 [-0.3; 0.5] Pa and 1.1% [-7%; 9%], respectively). In control patients, WSS was stable over time (follow-up-baseline differences ≤0.02 Pa and 0.0%, respectively). Proximal aortic WSS decreased after AVR (n = 5; peak WSS difference ≤-0.41 Pa and at-risk area ≤-10%, P < .05 vs controls). WSS was increased after ARR in regions distal to the graft (peak WSS difference ≥0.16 Pa and at-risk area ≥4%, P < .05 vs AVR). Follow-up duration had no significant effects on these WSS changes, except when comparing ascending aortic peak WSS between ARR and AVR (P = .006). CONCLUSIONS Serial perioperative 4D flow MRI investigations showed distinct patterns of postsurgical changes in aortic WSS, which included both reductions and translocations. Larger longitudinal studies are warranted to validate these findings with clinical outcomes and prediction of risk of future aortic events.
Collapse
Affiliation(s)
- Emilie Bollache
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Paul W M Fedak
- Department of Cardiac Sciences, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada; Division of Surgery-Cardiac Surgery, Northwestern University, Chicago, Ill
| | - Pim van Ooij
- Department of Radiology, Academic Medical Center, Amsterdam, The Netherlands
| | - Ozair Rahman
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - S Chris Malaisrie
- Division of Surgery-Cardiac Surgery, Northwestern University, Chicago, Ill
| | - Patrick M McCarthy
- Division of Surgery-Cardiac Surgery, Northwestern University, Chicago, Ill
| | - James C Carr
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Alex Powell
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Jeremy D Collins
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill
| | - Michael Markl
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill; Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Chicago, Ill
| | - Alex J Barker
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Ill.
| |
Collapse
|
7
|
Lee JC, Branch KR, Hamilton-Craig C, Krieger EV. Evaluation of aortic regurgitation with cardiac magnetic resonance imaging: a systematic review. Heart 2017; 104:103-110. [PMID: 28822982 DOI: 10.1136/heartjnl-2016-310819] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Revised: 07/31/2017] [Indexed: 11/03/2022] Open
Abstract
This review summaries the utility, application and data supporting use of cardiac magnetic resonance imaging (CMR) to evaluate and quantitate aortic regurgitation. We systematically searched Medline and PubMed for original research articles published since 2000 that provided data on the quantitation of aortic regurgitation by CMR and identified 11 articles for review. Direct aortic measurements using phase contrast allow quantitation of volumetric flow across the aortic valve and are highly reproducible and accurate compared with echocardiography. However, this technique requires diligence in prescribing the correct imaging planes in the aorta. Volumetric analytic techniques using differences in ventricular volumes are also highly accurate but less than phase contrast techniques and only accurate when concomitant valvular disease is absent. Comparison of both aortic and ventricular data for internal data verification ensures fidelity of aortic regurgitant data. CMR data can be applied to many types of aortic valve regurgitation including combined aortic stenosis with regurgitation, congenital valve diseases and post-transcatheter valve placement. CMR also predicts those patients who progress to surgery with high overall sensitivity and specificity. Future studies of CMR in patients with aortic regurgitation to quantify the incremental benefit over echocardiography as well as prediction of cardiovascular events are warranted.
Collapse
Affiliation(s)
- James C Lee
- Division of Cardiology, Department of Medicine, University of Washington, Seattle, Washington, USA
| | - Kelley R Branch
- Division of Cardiology, Department of Medicine, University of Washington, Seattle, Washington, USA
| | - Christian Hamilton-Craig
- Division of Cardiology, Department of Medicine, University of Washington, Seattle, Washington, USA.,Centre for Advanced Imaging, University of Queensland, Brisbane, Queensland, Australia.,Department of Cardiology, Heart & Lung Institute, The Prince Charles Hospital, Brisbane, Queensland, Australia
| | - Eric V Krieger
- Division of Cardiology, Department of Medicine, University of Washington, Seattle, Washington, USA.,Seattle Adult Congenital Heart Service, University of Washington School of Medicine, Seattle, Washington, USA
| |
Collapse
|
8
|
Abstract
OPINION STATEMENT Chronic aortic regurgitation can result from various congenital and acquired anomalies and can be associated with proximal aortic disease. As the number of aortic valve procedures is growing, the incidence of post-procedural regurgitation also increases with associated morbidity. Typical evolution is characterized by a clinically silent phase of variable duration followed by a rather rapid decline with high incidence of adverse events. A challenge remains to find the optimal timing for an intervention: Patients are exposed to unnecessary surgical risks if treated prematurely, but peri- and post-operative prognosis is worse when the intervention is performed too late. Clinical evaluation and serial imaging tests can optimize the timing for intervention. Clinical follow-up should try to elucidate associated symptoms, with quantitative measurement of functional capacity as needed. Serial imaging examinations are required to identify sub-clinical left ventricular dysfunction or severe dilatation that should prompt a surgery. At least in selected cases, newer imaging modalities (MRI, 3D echocardiography) and/or biomarkers can help for the management of these patients, and more research is needed to determine if their systematic use can be beneficial. Medical treatment with vasodilators and anti-remodeling drugs can be helpful in some patients but should not replace or delay aortic valve surgery when indicated. Most patients will eventually be treated with surgical aortic valve replacement. Although possible in selected cases, transcatheter aortic valve replacement is not commonly used for patients with pure aortic regurgitation. For patients with prior aortic valve replacement and aortic regurgitation (paravalvular or intravalvular), emerging percutaneous approaches can be considered when available, especially for those at high surgical risk.
Collapse
|
9
|
Lancellotti P, Piazza N, Modine T. Quantification of paravalvular regurgitation after transcatheter aortic valve implantation: improved accuracy means better standardization. Eur Heart J Cardiovasc Imaging 2016; 17:861-2. [PMID: 27252487 DOI: 10.1093/ehjci/jew110] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Patrizio Lancellotti
- Department of Cardiology, University of Liège Hospital, GIGA Cardiovascular Sciences, Heart Valve Clinic, CHU Sart Tilman, Liège 4000, Belgium Gruppo Villa Maria Care and Research, Anthea Hospital, Bari, Italy
| | - Nicolo Piazza
- McGill University Health Center, Interventional Cardiology, Montreal, Canada
| | - Thomas Modine
- Service de chirurgie cardiovasculaire, Institut cardiopulmonaire, CHRU de Lille, Liège, France
| |
Collapse
|
10
|
Abdelghani M, Soliman OI, Schultz C, Vahanian A, Serruys PW. Adjudicating paravalvular leaks of transcatheter aortic valves: a critical appraisal. Eur Heart J 2016; 37:2627-44. [DOI: 10.1093/eurheartj/ehw115] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/07/2015] [Accepted: 03/01/2016] [Indexed: 12/18/2022] Open
|