1
|
Yuan H, Wu Z, Lu T, Wei T, Zeng Y, Liu Y, Huang C. Comparison of biodegradable and durable polymer drug-eluting stents in acute coronary syndrome: a meta-analysis. BMJ Open 2022; 12:e058075. [PMID: 35676012 PMCID: PMC9185674 DOI: 10.1136/bmjopen-2021-058075] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Abstract
OBJECTIVE To compare the safety and effectiveness between biodegradable polymer drug-eluting stents (BP-DES) and durable polymer drug-eluting stents (DP-DES) in patients with acute coronary syndrome (ACS). DESIGN Meta-analysis of randomised controlled trials (RCTs). PRIMARY AND SECONDARY OUTCOME MEASURES Major adverse cardiovascular events (MACEs) were considered the primary endpoint. Efficacy endpoints included target vessel revascularisation (TVR) and target lesion revascularisation (TLR). Safety endpoints included all-cause death, cardiac death, target vessel myocardial infarction and stent thrombosis (ST). METHODS We searched PubMed, Medline, Embase and the Cochrane Controlled Register of Trials for comparative studies of BP-DES and DP-DES in patients with ACS from January 2000 to July 2021. Statistical pooling was performed to estimate incidence using a random-effects model with generic inverse-variance weighting. Risk estimates were computed with 95% CIs. RESULTS Eight articles with seven RCTs that compared BP-DES and DP-DES in patients with ACS were identified and included in the qualitative and quantitative analyses. There was no difference in the baseline characteristics, except for the number of smoking patients (OR: 1.13, 95% CI 1.03 to 1.24; p=0.008, I2=29%), which was significantly lower in the BP-DES group. The meta-analysis demonstrated that MACEs, efficacy endpoints and safety endpoints were similar between the groups at 1 year. However, the incidence of total ST was significantly different between the BP-DES and DP-DES groups in the follow-up period (p=0.0001). Further analysis showed a statistically significant difference in MACEs (OR: 0.71, 95% CI 0.57 to 0.88; p=0.002, I2=0 %), TLR (OR: 0.71, 95% CI 0.51 to 1.01; p=0.05, I2=0%), TVR (OR: 0.70, 95% CI 0.52 to 0.94; p=0.002, I2=15%), total ST incidence (OR: 0.59, 95% CI 0.46 to 0.77; p=0.0001, I2=48%) and ST incidence (OR: 0.63, 95% CI 0.47 to 0.85; p=0.002, I2=0%) over 2 years. CONCLUSION This meta-analysis revealed that both stent types demonstrated excellent safety and efficacy profiles at 12 months. However, a slight increase in MACEs, TLR, TVR and ST incidence was observed in the DP-DES group over the 2-year follow-up period, suggesting that BP-DES may be more favourable when treating patients with ACS. TRIAL REGISTRATION NUMBER NCT00389220.
Collapse
Affiliation(s)
- Haoyong Yuan
- Department of Cardiovascular Surgery, The second xiangya hospital of Central South University, Changsha, Hunan, China
- Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, Hunan, China
| | - Zhongshi Wu
- Department of Cardiovascular Surgery, The second xiangya hospital of Central South University, Changsha, Hunan, China
- Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, Hunan, China
| | - Ting Lu
- Department of Cardiovascular Surgery, The second xiangya hospital of Central South University, Changsha, Hunan, China
- Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, Hunan, China
| | - Tingting Wei
- Department of Paediatrics, Hunan Provincial Maternal and Child Health Care Hospital, Changsha, Hunan, China
| | - Yifan Zeng
- Department of Cardiovascular Surgery, The second xiangya hospital of Central South University, Changsha, Hunan, China
| | - Yalin Liu
- Department of Cardiovascular Surgery, The second xiangya hospital of Central South University, Changsha, Hunan, China
- Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, Hunan, China
| | - Can Huang
- Department of Cardiovascular Surgery, The second xiangya hospital of Central South University, Changsha, Hunan, China
- Engineering Laboratory of Hunan Province for Cardiovascular Biomaterials, Changsha, Hunan, China
| |
Collapse
|
2
|
Tomoi Y, Kuramitsu S, Shinozaki T, Hiramori S, Soga Y, Ando K. Temporal Course of Vascular Response After Fluoropolymer Paclitaxel-Eluting Stent Implantation for Femoropopliteal Artery Lesions. Circ J 2021; 85:2159-2165. [PMID: 33716266 DOI: 10.1253/circj.cj-20-1200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
BACKGROUND Limited data are available regarding the vascular response after fluoropolymer paclitaxel-eluting stent (FP-PES) implantation. This study sought to assess the vascular response at 6 and 12 months after FP-PES implantation for femoropopliteal artery lesions using serial optical coherence tomography (OCT) examination. METHODS AND RESULTS From the IMPERIAL trial, this study evaluated 10 de novo femoropopliteal lesions treated with FP-PES. The primary study endpoint was neointimal tissue coverage at a 6- and 12-month follow up, as assessed by serial OCT examination. The incidence of peri-strut low-intensity area (PLIA) and extra-stent lumen (ESL) was also assessed. A total of 203 matched cross-sectional images were evaluated at 6 and 12 months (5,615 and 5,763 struts, respectively). From 6 to 12 months, the mean neointimal thickness tended to increase from 198 µm to 233 µm, with a significant reduction in the incidence of malapposed struts (0.59% vs. 0.28%, P=0.039). Conversely, uncovered struts and PLIA were more frequently observed at 12 months (4.4% vs. 7.8%, P=0.01; 12.7% vs. 21.0%, P<0.001, respectively). The ESL area significantly increased over time without any difference in its incidence (0.24±0.32 mm2vs. 0.38±0.36 mm2, P=0.009). CONCLUSIONS Neointimal proliferation was markedly inhibited from 6 to 12 months after FP-PES implantation, whereas the incidence of uncovered struts and PLIA significantly increased over time with the enlargement of ESL.
Collapse
Affiliation(s)
- Yusuke Tomoi
- Department of Cardiology, Kokura Memorial Hospital
| | | | - Tomohiro Shinozaki
- Department of Information and Computer Technology, Faculty of Engineering, Tokyo University of Science
| | | | | | - Kenji Ando
- Department of Cardiology, Kokura Memorial Hospital
| |
Collapse
|
3
|
A serial optical frequency-domain imaging study of early and late vascular responses to bioresorbable-polymer sirolimus-eluting stents for the treatment of acute myocardial infarction and stable coronary artery disease patients: results of the MECHANISM-ULTIMASTER study. Cardiovasc Interv Ther 2021; 37:281-292. [PMID: 33895962 PMCID: PMC8926965 DOI: 10.1007/s12928-021-00777-4] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2020] [Accepted: 04/13/2021] [Indexed: 11/04/2022]
Abstract
The purpose of this study was to assess early and late vascular healing in response to bioresorbable-polymer sirolimus-eluting stents (BP-SESs) for the treatment of patients with ST-elevation myocardial infarction (STEMI) and stable coronary artery disease (CAD). A total of 106 patients with STEMI and 101 patients with stable-CAD were enrolled. Optical frequency-domain images were acquired at baseline, at 1- or 3-month follow-up, and at 12-month follow-up. In the STEMI and CAD cohorts, the percentage of uncovered struts (%US) was significantly and remarkably decreased during early two points and at 12-month (the STEMI cohort: 1-month: 18.75 ± 0.78%, 3-month: 10.19 ± 0.77%, 12-month: 1.80 ± 0.72%; p < 0.001, the CAD cohort: 1-month: 9.44 ± 0.78%, 3-month: 7.78 ± 0.78%, 12-month: 1.07 ± 0.73%; p < 0.001 respectively). The average peri-strut low-intensity area (PLIA) score in the STEMI cohort was significantly decreased during follow-up period (1.90 ± 1.14, 1.18 ± 1.25, and 1.01 ± 0.72; p ≤ 0.001), whereas the one in the CAD cohort was not significantly changed (0.89 ± 1.24, 0.67 ± 1.07, and 0.64 ± 0.72; p = 0.59). In comparison with both groups, differences of %US and PLIA score at early two points were almost disappeared or close at 12 months. The strut-coverage and healing processes in the early phase after BP-SES implantation were significantly improved in both cohorts, especially markedly in STEMI patients. At 1 year, qualitatively and quantitatively consistent neointimal coverage was achieved in both pathogenetic groups.
Collapse
|
4
|
Tomaniak M, Kołtowski Ł, Pietrasik A, Rdzanek A, Jąkała J, Proniewska K, Malinowski K, Mazurek T, Filipiak KJ, Brugaletta S, Opolski G, Kochman J. A serial 3- and 9-year optical coherence tomography assessment of vascular healing response to sirolimus- and paclitaxel-eluting stents. Int J Cardiovasc Imaging 2018; 35:9-21. [PMID: 30168010 PMCID: PMC6373305 DOI: 10.1007/s10554-018-1437-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/20/2018] [Accepted: 08/06/2018] [Indexed: 11/29/2022]
Abstract
Early-generation drug-eluting stents (DES) have been demonstrated to delay vascular healing. Limited optical coherence tomography (OCT) data on the very long-term neointimal response after DES implantation are available. The aim of this study was a serial OCT assessment of neointimal thickness, stent strut coverage, malapposition, and protrusion as markers of neointimal response at 3 and 9 years after implantation of sirolimus-eluting stents (SES) and paclitaxel-eluting stents (PES). In this single-centre, longitudinal study consecutive patients undergoing elective PCI with SES or PES were included. OCT analysis was performed after 3 and 9 years by the independent core laboratory. A total of 22 subjects (8 SES and 14 PES) underwent an OCT assessment at 3 and 9 years post index procedure. The lumen, neointimal and malapposition area and the neointimal thickness (SES ∆50 µm, p = 0.195, PES ∆10 µm, p = 0.951) did not change significantly over the 6 year follow-up. No differences in the incidence of uncovered, malapposed or protruding struts were found in each type of stent. At 3 and 9 years after PCI, implantation of early-generation SES and PES may be associated with similar neointimal thickness, strut coverage, malapposition and protrusion, as assessed by serial OCT examination among patients with uneventful follow-up at 3 years post procedure. The small size of the study warrants judicious interpretation of our results and confirmation in larger multimodality imaging studies, including patients treated with contemporary stent platforms.
Collapse
Affiliation(s)
- Mariusz Tomaniak
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland.
| | - Łukasz Kołtowski
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland
| | - Arkadiusz Pietrasik
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland
| | - Adam Rdzanek
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland
| | - Jacek Jąkała
- Krakow Cardiovascular Research Institute, Krakow, Poland
| | | | | | - Tomasz Mazurek
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland
| | - Krzysztof J Filipiak
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland
| | - Salvatore Brugaletta
- Institut Clinic Cardiovascular, IDIBAPS, Hospital Clinic, University of Barcelona, Barcelona, Spain
| | - Grzegorz Opolski
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland
| | - Janusz Kochman
- First Department of Cardiology, Medical University of Warsaw, ul. Banacha 1a, 02-097, Warsaw, Poland
| |
Collapse
|
5
|
Kuramitsu S, Sonoda S, Shinozaki T, Jinnouch H, Muraoka Y, Domei T, Hyodo M, Shirai S, Ando K, Otsuji Y. Impact of lesion complexity on long-term vascular response to cobalt-chromium everolimus-eluting stent: five-year follow-up optical coherence tomography study. Heart Vessels 2017; 33:341-350. [PMID: 29051975 DOI: 10.1007/s00380-017-1068-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/11/2017] [Accepted: 10/13/2017] [Indexed: 11/25/2022]
Abstract
The impact of lesion complexity on long-term vascular response to cobalt-chromium everolimus-eluting stent (CoCrEES) remains unclear. We sought to evaluate them using optical coherence tomography (OCT). A total of 47 patients with 58 lesions treated only with CoCrEES and no target-vessel events within 5 years after implantation were prospectively enrolled and underwent 5-year follow-up OCT. Quantitative parameters and qualitative characteristics of the neointima were evaluated using multilevel logistic or linear regression models with random effects at three levels: lesion, cross-section (CS), and strut. According to the lesion complexity, the lesions were classified into the two groups: the complex lesion (CL) and non-CL group. The CL was defined as having at least 1 high-risk feature such as acute coronary syndrome lesion, lesion length > 20 mm, severe calcification requiring rotational atherectomy, and chronic total occlusion at the index procedure. A total of 11,034 struts (CL, n = 6240; non-CL, n = 4794) and 1202 (CL, n = 683; non-CL, n = 519) CSs were analyzed. The percentage of uncovered and malapposed struts did not differ significantly between the CL and non-CL groups (0.90 vs. 0.54%, P = 0.78; 0.56 vs. 0.10%, P = 0.16, respectively). The incidence of neoatherosclerosis was comparable between both groups in the CS- and lesion-level analysis (3.5 vs. 4.6%, P = 0.91; 32.0 vs. 24.2%, P = 0.52, respectively). At 5 years, CoCrEES shows an excellent vascular healing and similar frequency of neoatheroslerosis in patients without target-vessel events, regardless of the lesion complexity.
Collapse
Affiliation(s)
- Shoichi Kuramitsu
- Department of Cardiology, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita-ku, Kitakyushu, 802-8555, Japan.
| | - Shinjo Sonoda
- Department of Internal Medicine, University of Occupational and Environmental Health Japan School of Medicine, Kitakyushu, Japan
| | - Tomohiro Shinozaki
- Department of Biostatistics, School of Public Health, The University of Tokyo, Tokyo, Japan
| | - Hiroyuki Jinnouch
- Department of Cardiology, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita-ku, Kitakyushu, 802-8555, Japan
| | - Yoshitaka Muraoka
- Department of Internal Medicine, University of Occupational and Environmental Health Japan School of Medicine, Kitakyushu, Japan
| | - Takenori Domei
- Department of Cardiology, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita-ku, Kitakyushu, 802-8555, Japan
| | - Makoto Hyodo
- Department of Cardiology, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita-ku, Kitakyushu, 802-8555, Japan
| | - Shinichi Shirai
- Department of Cardiology, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita-ku, Kitakyushu, 802-8555, Japan
| | - Kenji Ando
- Department of Cardiology, Kokura Memorial Hospital, 3-2-1 Asano, Kokurakita-ku, Kitakyushu, 802-8555, Japan
| | - Yutaka Otsuji
- Department of Internal Medicine, University of Occupational and Environmental Health Japan School of Medicine, Kitakyushu, Japan
| |
Collapse
|
6
|
The Ultimaster Biodegradable-Polymer Sirolimus-Eluting Stent: An Updated Review of Clinical Evidence. Int J Mol Sci 2016; 17:ijms17091490. [PMID: 27608017 PMCID: PMC5037768 DOI: 10.3390/ijms17091490] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2016] [Revised: 08/27/2016] [Accepted: 08/31/2016] [Indexed: 01/23/2023] Open
Abstract
The Ultimaster coronary stent system (Terumo Corporation, Tokyo, Japan) represents a new iteration in drug-eluting stent (DES) technology that has recently received the Conformité Européenne (CE) mark approval for clinical use. The Ultimaster is a thin-strut, cobalt chromium, biodegradable-polymer, sirolimus-eluting coronary stent. The high elasticity of the biodegradable-polymer (PDLLA-PCL) and the abluminal gradient coating technology are additional novel features of this coronary device. The Ultimaster DES has undergone extensive clinical evaluation in two studies: The CENTURY I and II trials. Results from these two landmark studies suggested an excellent efficacy and safety profile of the Ultimaster DES across several lesion and patient subsets, with similar clinical outcomes to contemporary, new-generation DES. The aim of this review is to summarize the rationale behind this novel DES technology and to provide an update of available evidence about the clinical performance of the Ultimaster DES.
Collapse
|
7
|
Puricel S, Cook S, Arroyo D. Coronary healing after stenting: wounds, faith, and the quest for the perfect stent. Eur Heart J Cardiovasc Imaging 2015; 17:12-4. [PMID: 26377906 DOI: 10.1093/ehjci/jev226] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Affiliation(s)
- Serban Puricel
- Department of Cardiology, University and Hospital Fribourg, Fribourg CH-1708, Switzerland
| | - Stéphane Cook
- Department of Cardiology, University and Hospital Fribourg, Fribourg CH-1708, Switzerland
| | - Diego Arroyo
- Department of Cardiology, University and Hospital Fribourg, Fribourg CH-1708, Switzerland
| |
Collapse
|