1
|
Multi-lead pacing for cardiac resynchronization therapy in heart failure: a meta-analysis of randomized controlled trials. EUROPEAN HEART JOURNAL OPEN 2022; 2:oeac013. [PMID: 35919119 PMCID: PMC9242027 DOI: 10.1093/ehjopen/oeac013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 01/25/2022] [Accepted: 02/25/2022] [Indexed: 11/13/2022]
Abstract
Aims Multi-lead pacing is a potential therapy to improve response to cardiac resynchronization therapy (CRT) by providing rapid activation of the myocardium from multiple sites. Here, we perform a meta-analysis of randomized controlled trials to assess the efficacy of multi-lead pacing. Methods and results A literature search was performed which identified 251 unique records. After screening, 6 studies were found to meet inclusion criteria, with 415 patients included in the meta-analysis. Four studies performed multi-lead pacing with two left ventricular (LV) leads and one right ventricular (RV) lead. One study used two RV leads and one LV lead, and one study used both configurations. There was no difference between multi-lead pacing and conventional CRT in LV end-systolic volume [mean difference (MD) -0.54 mL, P = 0.93] or LV ejection fraction (MD 1.42%, P = 0.40). There was a borderline significant improvement in Minnesota Living With Heart Failure Questionnaire score for multi-lead pacing vs. conventional CRT (MD -4.46, P = 0.05), but the difference was not significant when only patients receiving LV-only multi-lead pacing were included (MD -3.59, P = 0.25). There was also no difference between groups for 6-min walk test (MD 15.06 m, P = 0.38) or New York Heart Association class at follow-up [odds ratio (OR) 1.49, P = 0.24]. There was no difference in mortality between groups (OR 1.11, P = 0.77). Conclusion This meta-analysis does not support the use of multi-lead pacing for CRT delivery. However, significant variation between studies was noted, and therefore a benefit for multi-lead pacing in select patients cannot be excluded, and further investigation may be warranted.
Collapse
|
2
|
Amulet™ Shines and Protects; Pacing Battle Intensifies with "More Leads or No Leads"? J Innov Card Rhythm Manag 2022; 13:4833-4839. [PMID: 35127236 PMCID: PMC8812483 DOI: 10.19102/icrm.2022.130110] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
3
|
Rationale and design of a randomized clinical trial to assess the safety and efficacy of multipoint pacing therapy: MOre REsponse on Cardiac Resynchronization Therapy with MultiPoint Pacing (MORE-CRT MPP-PHASE II). Am Heart J 2019; 209:1-8. [PMID: 30616009 DOI: 10.1016/j.ahj.2018.12.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/25/2017] [Accepted: 12/03/2018] [Indexed: 11/22/2022]
Abstract
BACKGROUND Although cardiac resynchronization therapy (CRT) is beneficial in most heart failure patients, up to 40% do not respond to CRT. Data from the MultiPoint Pacing (MPP) IDE trial and MORE-CRT MPP-PHASE I study suggest improved response in subjects in the MPP arm-programmed with wide left ventricular (LV) electrode anatomical separation (≥30 mm) and shortest timing delays of 5 milliseconds (MPP-AS)-compared with quadripolar biventricular (BiV) pacing. STUDY DESIGN The MORE-CRT MPP-PHASE II trial is a prospective, randomized, multicenter study to assess the 6-month impact of MPP programmed to mandated MPP-AS settings in subjects who do not respond to 6 months of BiV pacing (MPP OFF). Approximately 5,000 subjects with a standard CRT indication will be enrolled and implanted with a quadripolar CRT system (Abbott) capable of delivering MPP. Only BiV pacing is activated at implant. At 6 months, subjects classified as CRT nonresponders (<15% reduction in LV end-systolic volume) are randomized (1:1) to MPP or continued BiV pacing. The mandated MPP parameters (eg, MPP-AS) are programmed to subjects randomized to the MPP arm. At 12 months, the 2 groups will be compared to determine if there is a difference in CRT response rate. CONCLUSIONS This trial will evaluate whether MPP programmed to mandated MPP-AS settings improves LV reverse remodeling and clinical response to CRT in patients who fail to respond to 6 months of BiV pacing (www.clinicaltrials.gov identifier NCT02006069).
Collapse
|
4
|
Abstract
Cardiac resynchronization therapy (CRT) reduces morbidity and mortality in patients with broad QRS complex ≥130 ms and heart failure with reduced ejection fraction despite optimal guideline-directed medical therapy. However, approximately 30% of the patients implanted with a CRT system do not show clinical benefit. Reasons for nonresponse are complex and some aspects can be addressed during follow-up. Based on quadripolar lead technology, multipoint pacing (MPP) allows left ventricular stimulation at two different sites along the lead. In particular, in scarred and fibrotic ventricular myocardium stimulation at two different sites may overcome conduction barriers and lead to homogeneous ventricular depolarization. Especially for patients that do not respond to conventional CRT, activation of MPP may present an option to increase clinical response. On the other hand, MPP may significantly decrease battery longevity.This review offers an overview of the current knowledge and data on MPP balancing the potential clinical benefit and the possible disadvantages of this therapy.
Collapse
|
5
|
Cardiac resynchronization is pro-arrhythmic in the absence of reverse ventricular remodelling: a systematic review and meta-analysis. Cardiovasc Res 2018; 114:1435-1444. [PMID: 30010807 DOI: 10.1093/cvr/cvy182] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2018] [Accepted: 09/27/2018] [Indexed: 11/14/2022] Open
Abstract
Aims Cardiac resynchronization therapy (CRT) has been shown to reduce mortality and heart failure (HF) hospitalization but its effects on the rate of ventricular arrhythmias (VAs) appears to be neutral. We hypothesize that CRT with LV epicardial stimulation is inherently pro-arrhythmic and increases VA rates in the absence of reverse ventricular remodelling while conferring an anti-arrhythmic effect in mechanical responders. Methods and results In this systematic review and meta-analysis, we considered retrospective cohort, prospective cohort, and randomized controlled trials comparing VA rates between cardiac resynchronization therapy-defibrillator (CRT-D) non-responders, CRT-D responders and those with implantable cardioverter-defibrillator (ICD) only. Studies were eligible if they defined CRT-D responders using a discrete left ventricular volumetric value as assessed by any imaging modality. Studies were identified through searching electronic databases from their inception to July 2017. We identified 2579 citations, of which 23 full-text articles were eligible for final analysis. Our results demonstrated that CRT-D responders were less likely to experience VA than CRT-D non-responders, relative risk (RR) 0.49 [95% confidence interval (CI) 0.41-0.58, P < 0.01] and also less than patients with ICD only: RR 0.59 (95% CI 0.50-0.69, P < 0.01). However, CRT-D mechanical non-responders had a greater likelihood of VA compared with ICD only, RR 0.76 (95% CI 0.63-0.92, P = 0.004). Conclusion CRT-D non-responders experienced more VA than CRT-D responders and also more than those with ICD only, suggesting that CRT with LV epicardial stimulation may be inherently pro-arrhythmic in the absence of reverse remodelling.
Collapse
|
6
|
Triple-site pacing for cardiac resynchronization in permanent atrial fibrillation: follow-up results from a prospective observational study. Europace 2018; 20:986-992. [PMID: 28430960 DOI: 10.1093/europace/eux036] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2016] [Accepted: 02/16/2017] [Indexed: 11/14/2022] Open
Abstract
Aims Cardiac Resynchronization Therapy (CRT) is associated with a particularly high non-response rate in patients with atrial fibrillation (AF). We aimed to assess the effectiveness of triple-site (Tri-V) pacing CRT in this population. Methods and results Prospective observational study of patients with permanent AF who underwent CRT implantation with an additional right ventricle lead in the outflow tract septal wall. After implantation, programming mode (Tri-V or biventricular pacing) was selected based on cardiac output determination. Patients were classified as responders if NYHA class was reduced by at least one level and echocardiographic ejection fraction (EF) increased ≥ 10%, and as super-responders if in NYHA class I and EF ≥ 50%. Forty patients (93% male, mean age 72 ± 10 years) were included. Thirty-three were programmed in Tri-V. The following results pertain to this subgroup. At baseline, 58% were in NYHA class III and 36% NYHA class II. At 1 year follow-up, Minnesota QoL score was reduced (36 ± 23 vs. 8 ± 6; P = 0.001) and the 6MWT distance improved (384 ± 120 m to 462 ± 87 m, P = 0.003). Mean EF increased (26% ± 8 vs. 39 ± 10; P < 0.001 at 6 months and 41 ± 10; P < 0.001 at 12 months). Responder rate was 59% at 6 months and 79% at 12 months. Super-responder rate was 9% at 6 months and 16% at 12 months. One year survival free from heart failure hospitalization was 87.9%. Conclusion Tri-V CRT yielded higher response and super-response rates than usually reported for CRT in patients with permanent AF using clinical and remodeling criteria.
Collapse
|
7
|
Comparison of triple-site ventricular pacing versus conventional cardiac resynchronization therapy in patients with systolic heart failure: A meta-analysis of randomized and observational studies. J Arrhythm 2018; 34:55-64. [PMID: 29721114 PMCID: PMC5828262 DOI: 10.1002/joa3.12018] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Accepted: 11/08/2017] [Indexed: 12/03/2022] Open
Abstract
Background Conventional cardiac resynchronization therapy (CRT, Bi‐V) is associated with no response in about 40% patients due to an insufficient resynchronization. Some studies showed triple‐site ventricular (Tri‐V) pacing had greater benefits compared with Bi‐V pacing, but the results of these studies were conflicting. We hypothesized that Tri‐V pacing had greater benefits on long‐term outcomes compared with Bi‐V pacing in patients with heart failure. Methods PubMed, EMBASE, and the Cochrane Library were searched for clinical studies with related outcomes. Weighted mean differences (WMD) and 95% confidence intervals (CIs) were calculated to compare the change in left ventricular ejection fraction (LVEF), left ventricular geometry, functional capacity, and quality of life between Tri‐V pacing group and control group. Results Five trials with 251 patients were included in the analysis. Patients in the Tri‐V pacing group had a greater improvement in LVEF (WMD 4.04; 95% CI 2.15‐5.92, P < .001) and NYHA classes (WMD −0.27; 95% CI −0.42 to −0.11, P = .001) compared with control group. However, there were no significant differences in left ventricular geometry, six‐min walk distance, or Minnesota Living With Heart Failure Questionnaire score between the two groups. The subgroup analyses showed there might be a greater improvement in LVEF in the Tri‐V pacing group in patients with QRS duration ≥ 155 ms (WMD 5.60; 95% CI 3.09‐8.10, P < .001). Conclusions The present analysis suggests that Tri‐V pacing has greater benefits in terms of an improvement in LVEF and functional capacity in patients with systolic heart failure, especially in patients with the duration of QRS ≥ 155 ms.
Collapse
|
8
|
How to deliver optimal cardiac resynchronisation therapy. Heart 2017; 104:1300-1307. [PMID: 29217631 DOI: 10.1136/heartjnl-2017-311210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2017] [Revised: 08/24/2017] [Accepted: 11/02/2017] [Indexed: 01/06/2023] Open
|
9
|
Safety and Efficacy of Multipoint Pacing in Cardiac Resynchronization Therapy. JACC Clin Electrophysiol 2017; 3:1510-1518. [DOI: 10.1016/j.jacep.2017.06.022] [Citation(s) in RCA: 44] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2017] [Revised: 06/23/2017] [Accepted: 06/26/2017] [Indexed: 10/18/2022]
|
10
|
Updates in Cardiac Resynchronization Therapy for Chronic Heart Failure: Review of Multisite Pacing. Curr Heart Fail Rep 2017; 14:376-383. [DOI: 10.1007/s11897-017-0350-z] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Rationale and design of a randomized trial to assess the safety and efficacy of MultiPoint Pacing (MPP) in cardiac resynchronization therapy: The MPP Trial. Ann Noninvasive Electrocardiol 2017; 22. [PMID: 28517367 DOI: 10.1111/anec.12448] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 03/10/2017] [Indexed: 01/08/2023] Open
Abstract
BACKGROUND Although the majority of Class III congestive heart failure (HF) patients treated with cardiac resynchronization therapy (CRT) show a clinical benefit, up to 40% of patients do not respond to CRT. This paper reports the design of the MultiPoint Pacing (MPP) trial, a prospective, randomized, double-blind, controlled study to evaluate the safety and efficacy of CRT using MPP compared to standard biventricular (Bi-V) pacing. METHODS A maximum of 506 patients with a standard CRT-D indication will be enrolled at up to 50 US centers. All patients will be implanted with a CRT-D system (Quartet LV lead Model 1458Q with a Quadra CRT-D, Abbott) that can deliver both MPP and Bi-V pacing. Standard Bi-V pacing will be activated at implant. At 3 months postimplant, patients in whom the echocardiographic parameters during MPP are equal or better than during Bi-V pacing are randomized (1:1) to either an MPP or Bi-V arm. RESULTS The primary safety endpoint is freedom from system-related complications at 9 months. Each patient's response to CRT will be evaluated using a heart-failure clinical composite score, consisting of a change in NYHA functional class, patient global assessment score, HF events, and cardiovascular death. The primary efficacy endpoint is the proportion of responders in the MPP arm compared with the Bi-V arm between 3 and 9 months. CONCLUSION This trial seeks to evaluate whether MPP via a single quadripolar LV lead improves hemodynamic and clinical responses to CRT, both in clinical responders and nonresponders.
Collapse
|
12
|
|
13
|
Long-Term Results of Triventricular Versus Biventricular Pacing in Heart Failure. JACC Clin Electrophysiol 2016; 2:825-835. [DOI: 10.1016/j.jacep.2016.05.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2016] [Accepted: 05/12/2016] [Indexed: 10/21/2022]
|
14
|
Triventricular Pacing. JACC Clin Electrophysiol 2016; 2:836-837. [DOI: 10.1016/j.jacep.2016.08.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2016] [Revised: 08/15/2016] [Accepted: 08/15/2016] [Indexed: 10/20/2022]
|
15
|
Right bundle branch block and heart failure: Can a bifocal right ventricular pacing be an alternative to biventricular pacing? COR ET VASA 2016. [DOI: 10.1016/j.crvasa.2016.01.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
16
|
Innovative pacing: Recent advances, emerging technologies, and future directions in cardiac pacing. Trends Cardiovasc Med 2016; 26:452-63. [PMID: 27017442 DOI: 10.1016/j.tcm.2016.02.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/22/2015] [Revised: 02/15/2016] [Accepted: 02/17/2016] [Indexed: 11/20/2022]
Abstract
The field of cardiovascular medicine is rapidly evolving as advancements in technology and engineering provide clinicians new and exciting ways to care for an aging population. Cardiac pacing, in particular, has seen a series of game-changing technologies emerge in the past several years spurred by low-power electronics, high density batteries, improved catheter delivery systems and innovative software design. We look at several of these emerging pacemaker technologies, discussing the rationale, current state and future directions of these pioneering developments in electrophysiology.
Collapse
|
17
|
Triple-site pacing for cardiac resynchronization in permanent atrial fibrillation - Acute phase results from a prospective observational study. Rev Port Cardiol 2016; 35:331-8. [PMID: 27255170 DOI: 10.1016/j.repc.2015.12.006] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2015] [Accepted: 12/20/2015] [Indexed: 11/22/2022] Open
Abstract
INTRODUCTION AND AIM Multi-site pacing is emerging as a new method for improving response to cardiac resynchronization therapy (CRT), but has been little studied, especially in patients with atrial fibrillation. We aimed to assess the effects of triple-site (Tri-V) vs. biventricular (Bi-V) pacing on hemodynamics and QRS duration. METHODS This was a prospective observational study of patients with permanent atrial fibrillation and ejection fraction <40% undergoing CRT implantation (n=40). One right ventricular (RV) lead was implanted in the apex and another in the right ventricular outflow tract (RVOT) septal wall. A left ventricular (LV) lead was implanted in a conventional venous epicardial position. Cardiac output (using the FloTrac™ Vigileo™ system), mean QRS and ejection fraction were calculated. RESULTS Mean cardiac output was 4.81±0.97 l/min with Tri-V, 4.68±0.94 l/min with RVOT septal and LV pacing, and 4.68±0.94 l/min with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV). Mean pre-implantation QRS was 170±25 ms, 123±18 ms with Tri-V, 141±25 ms with RVOT septal pacing and LV pacing and 145±19 with RV apical and LV pacing (p<0.001 for Tri-V vs. both BiV and pre-implantation). Mean ejection fraction was significantly higher with Tri-V (30±11%) vs. Bi-V pacing (28±12% with RVOT septal and LV pacing and 28±11 with RV apical and LV pacing) and pre-implantation (25±8%). CONCLUSION Tri-V pacing produced higher cardiac output and shorter QRS duration than Bi-V pacing. This may have a significant impact on the future of CRT.
Collapse
|
18
|
Triple-site pacing for cardiac resynchronization in atrial fibrillation – an opening onto different scenarios. REVISTA PORTUGUESA DE CARDIOLOGIA (ENGLISH EDITION) 2016. [DOI: 10.1016/j.repce.2016.05.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022] Open
|
19
|
Triple-site pacing for cardiac resynchronization in permanent atrial fibrillation – Acute phase results from a prospective observational study. REVISTA PORTUGUESA DE CARDIOLOGIA (ENGLISH EDITION) 2016. [DOI: 10.1016/j.repce.2015.12.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022] Open
|
20
|
Pacing multi‐site para ressincronização cardíaca na fibrilhação auricular – uma janela com cenários diferentes. Rev Port Cardiol 2016; 35:339-41. [DOI: 10.1016/j.repc.2016.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
21
|
|
22
|
Hemodynamic effects of Purkinje potential pacing in the left ventricular endocardium in patients with advanced heart failure. J Arrhythm 2015; 31:371-5. [PMID: 26702317 PMCID: PMC4672074 DOI: 10.1016/j.joa.2015.06.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 06/03/2015] [Accepted: 06/16/2015] [Indexed: 11/14/2022] Open
Abstract
Background Various difficulties can occur in patients who undergo cardiac resynchronization therapy for drug-refractory heart failure with respect to placement of the left ventricular (LV) lead, because of anatomical features, pacing thresholds, twitching, or pacing lead anchoring, possibly requiring other pacing sites. The goal of this study was to determine whether Purkinje potential (PP) pacing could provide better hemodynamics in patients with left bundle branch block and heart failure than biventricular (BiV) pacing. Methods Eleven patients with New York Heart Association functional class II or III heart failure despite optimal medical therapy were selected for this study. All patients underwent left- and right-sided cardiac catheterization for measurement of LV functional parameters in the control state during BiV and PP pacing. Results Maximum dP/dt increased during BiV and PP pacing when compared with control measurements. This study compared parameters measured during BiV pacing with PP pacing and non-paced beats as the control state in each patient (717±171 mmHg/s vs. 917±191 mmHg/s, p<0.05; and 921±199 mmHg/s, p<0.005); however, the difference between PP pacing and BiV pacing was not significant. There was no difference in heart rate, electrocardiographic wave complex duration, minimum dP/dt, left ventricular end-diastolic pressure, left ventricular end-systolic pressure, pulmonary capillary wedge pressure, or cardiac index when comparing BiV pacing and PP pacing to control measurements. Conclusions The hemodynamic outcome of PP pacing was comparable to that of BiV pacing in patients with advanced heart failure.
Collapse
|
23
|
Safety, feasibility, and outcome results of cardiac resynchronization with triple-site ventricular stimulation compared to conventional cardiac resynchronization. Heart Rhythm 2015; 13:183-9. [PMID: 26325531 DOI: 10.1016/j.hrthm.2015.08.036] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2015] [Indexed: 11/26/2022]
Abstract
BACKGROUND The nonresponder rate to cardiac resynchronization therapy (CRT) may be due to incomplete resynchronization, with dyssynchrony persisting in approximately 30% of patients. We hypothesized that CRT with triple-site ventricular stimulation (TRIV) may improve resynchronization and its outcomes. OBJECTIVE The purpose of this study was to assess the feasibility and safety of TRIV and collected data on clinical outcomes to dimension future studies. METHODS Our pilot randomized trial was designed to assess the safety and feasibility of TRIV with 2 right ventricular leads and 1 left ventricular leads compared to conventional CRT. The primary end-point was the rate of severe adverse events at 6 months. Secondary end-points included functional improvement parameters, quality-of-life (QOL) score, and changes of echocardiographic indices at 6 and 12 months in a subset of patients. RESULTS Seventy-six patients were enrolled at 11 centers and randomized to control or TRIV arm. All implant procedures but one were successful. At 6 months, there was no statistical difference between proportions of patients with at least 1 severe adverse event in both groups (34.1% vs 25.7%, P = .425). There also was no difference between functional improvement parameters, 6-minute walking distances (P = .40), QOL scores (P = .27), and echographic indices. At 12 months, the proportions of patients with a left ventricular ejection fraction gain of more than 5%, 10%, or 15% were significantly superior with TRIV. CONCLUSION TRIV pacing is an effective and safe technique and may provide a greater benefit in ventricular remodeling than conventional CRT. Further studies are needed to assess its long-term benefit.
Collapse
|
24
|
Abstract
Cardiac resynchronisation therapy (CRT) is an effective intervention for appropriately selected patients with heart failure, but exactly how it works is uncertain. Recent data suggest that much, or perhaps most, of the benefits of CRT are not delivered by re-coordinating left ventricular dyssynchrony. Atrio-ventricular resynchronization, reduction in mitral regurgitation and prevention of bradycardia are other potential mechanisms of benefit that will vary from one patient to the next and over time. Because there is no single therapeutic target, it is unlikely that any single measure will accurately predict benefit. The only clinical characteristic that appears to be a useful predictor of the benefits of CRT is a QRS duration of >140 ms. Many new approaches are being developed to try to improve the effectiveness of and extend the indications for CRT. These include smart pacing algorithms, better pacing-site targeting, new sensors, multipoint pacing, remote device monitoring and leadless endocardial pacing. Whether CRT is effective in patients with atrial fibrillation or whether adding a defibrillator function to CRT improves prognosis awaits further evidence.
Collapse
|
25
|
Optimizing CRT - Do We Need More Leads and Delivery Methods. J Atr Fibrillation 2015; 7:1202. [PMID: 27957161 DOI: 10.4022/jafib.1202] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2015] [Revised: 04/23/2015] [Accepted: 04/24/2015] [Indexed: 11/10/2022]
Abstract
Cardiac resynchronization therapy (CRT) is an established therapeutic option in symptomatic heart failure with reduced ejection fraction and evidence of left ventricular (LV) conduction delay (QRS width ≥120 ms), especially when typical left bundle branch block is present. The rationale behind CRT is restoration of aberrant LV electrical activation. As there is considerable heterogeneity of the LV electrical activation pattern among CRT candidates, an individualized approach with targeting of the LV lead in the region of latest electrical activation while avoiding scar tissue may enhance CRT response. Echocardiography, electro anatomic mapping, and cardiac magnetic resonance imaging with late gadolinium enhancement are helpful to guide such targeted LV lead placement. However, an important limitation remains the anatomy of the coronary sinus, which often does not allow concordant LV lead placement in the optimal region. Epicardial LV lead placement through minimal invasive surgery or endocardial LV lead placement through transseptal punction may overcome this limitation, obviously with an increased complication risk. Furthermore, recent pacing algorithms suggest superiority of LV-only versus biventricular pacing in patients with preserved atrio ventricular (AV) conduction and a typical LBBB pattern. Finally, pacing from only one LV site might not overcome the wide electrical dispersion often seen in patients with LV conduction delays. Therefore, multisite pacing has gained significant interest to improve CRT response. The use of multiple LV leads may potentially lead to more favorable reverse remodeling, improved functional capacity and quality of life in CRT candidates, but adverse events and a shorter battery span are more frequent because of the extra lead. The use of one multipolar LV lead increases the number of pacing configurations within the same coronary sinus side branch (within small distances from each other) without the use of an additional lead. Small observational studies suggest that more effective resynchronization can be achieved with this approach. Finally, there are many reasons for non effective CRT delivery in carefully selected patients with an adequately implanted device. Multidisciplinary, post implantation care inside a dedicated CRT clinic ensures optimal CRT delivery, improves response rate and should be considered standard of care.
Collapse
|
26
|
|
27
|
Biventricular Pacing With Ventricular Fusion by Intrinsic Activation in Cardiac Resynchronization Therapy. Int Heart J 2015; 56:293-7. [DOI: 10.1536/ihj.14-260] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
28
|
|
29
|
Triventricular pacing improved dyssynchrony in heart failure patient with right-bundle branch block and left anterior fascicular block. J Cardiol Cases 2014; 9:158-161. [PMID: 30546790 DOI: 10.1016/j.jccase.2013.12.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2013] [Revised: 12/23/2013] [Accepted: 12/30/2013] [Indexed: 10/25/2022] Open
Abstract
The present case report describes a 53-year-old man with drug-resistant heart failure. Electrocardiogram showed complete right-bundle branch block and left anterior fascicular block. A cardiac resynchronization therapy (CRT) device was implanted in him because echocardiography showed obvious left ventricular dyssynchrony between septal and lateral walls. After CRT implantation, dyssynchrony was improved and ejection fraction was increased. Evaluation of coexisting left hemiblock and left ventricular dyssynchrony may be needed in patients with atypical indications for CRT. <Learning objective: Cardiac resynchronization therapy (CRT) for patients with complete right-bundle branch block (CRBBB) is still controversial. Presence of hemiblock and left ventricular dyssynchrony between the pacing sites may be essential to determine CRT indication even in patients with CRBBB.>.
Collapse
|
30
|
A randomized double-blind crossover trial of triventricular versus biventricular pacing in heart failure. Eur J Heart Fail 2014; 14:495-505. [DOI: 10.1093/eurjhf/hfs004] [Citation(s) in RCA: 58] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/31/2022] Open
|
31
|
Fusion-Optimized Intervals (FOI): A New Method to Achieve the Narrowest QRS for Optimization of the AV and VV Intervals in Patients Undergoing Cardiac Resynchronization Therapy. J Cardiovasc Electrophysiol 2013; 25:283-92. [DOI: 10.1111/jce.12322] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2013] [Revised: 10/07/2013] [Accepted: 10/14/2013] [Indexed: 01/19/2023]
|
32
|
2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and management. Europace 2013; 14:1236-86. [PMID: 22930717 DOI: 10.1093/europace/eus222] [Citation(s) in RCA: 196] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022] Open
|
33
|
2012 EHRA/HRS expert consensus statement on cardiac resynchronization therapy in heart failure: implant and follow-up recommendations and management. Heart Rhythm 2012; 9:1524-76. [PMID: 22939223 DOI: 10.1016/j.hrthm.2012.07.025] [Citation(s) in RCA: 184] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/26/2012] [Indexed: 11/30/2022]
|
34
|
Electrical storm after cardiac resynchronization therapy suppressed by triple-site biventricular pacing and atrioventricular nodal ablation. Heart Rhythm 2012; 9:2059-62. [PMID: 22863886 DOI: 10.1016/j.hrthm.2012.07.027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2012] [Indexed: 10/28/2022]
|
35
|
Cardiac resynchronization: what's next? Arch Cardiovasc Dis 2012; 105:335-7. [PMID: 22800717 DOI: 10.1016/j.acvd.2012.05.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/14/2012] [Accepted: 05/14/2012] [Indexed: 11/25/2022]
|
36
|
Localization and sub-cellular shuttling of HTLV-1 tax with the miRNA machinery. PLoS One 2012; 7:e40662. [PMID: 22808228 PMCID: PMC3393700 DOI: 10.1371/journal.pone.0040662] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2012] [Accepted: 06/11/2012] [Indexed: 12/18/2022] Open
Abstract
The innate ability of the human cell to silence endogenous retroviruses through RNA sequences encoding microRNAs, suggests that the cellular RNAi machinery is a major means by which the host mounts a defense response against present day retroviruses. Indeed, cellular miRNAs target and hybridize to specific sequences of both HTLV-1 and HIV-1 viral transcripts. However, much like the variety of host immune responses to retroviral infection, the virus itself contains mechanisms that assist in the evasion of viral inhibition through control of the cellular RNAi pathway. Retroviruses can hijack both the enzymatic and catalytic components of the RNAi pathway, in some cases to produce novel viral miRNAs that can either assist in active viral infection or promote a latent state. Here, we show that HTLV-1 Tax contributes to the dysregulation of the RNAi pathway by altering the expression of key components of this pathway. A survey of uninfected and HTLV-1 infected cells revealed that Drosha protein is present at lower levels in all HTLV-1 infected cell lines and in infected primary cells, while other components such as DGCR8 were not dramatically altered. We show colocalization of Tax and Drosha in the nucleus in vitro as well as coimmunoprecipitation in the presence of proteasome inhibitors, indicating that Tax interacts with Drosha and may target it to specific areas of the cell, namely, the proteasome. In the presence of Tax we observed a prevention of primary miRNA cleavage by Drosha. Finally, the changes in cellular miRNA expression in HTLV-1 infected cells can be mimicked by the add back of Drosha or the addition of antagomiRs against the cellular miRNAs which are downregulated by the virus.
Collapse
|
37
|
Left Ventricular Endocardial Pacing and Multisite Pacing to Improve CRT Response. J Cardiovasc Transl Res 2012; 5:213-8. [DOI: 10.1007/s12265-011-9342-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/03/2011] [Accepted: 12/12/2011] [Indexed: 10/14/2022]
|
38
|
Clinical and procedural characteristics of acute hemodynamic responders undergoing triple-site ventricular pacing for advanced heart failure. Am J Cardiol 2011; 108:1297-304. [PMID: 21855835 DOI: 10.1016/j.amjcard.2011.06.048] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/24/2011] [Revised: 06/13/2011] [Accepted: 06/13/2011] [Indexed: 11/27/2022]
Abstract
The advantages of triple-site ventricular pacing (Tri-V) compared to conventional biventricular site pacing (Bi-V) have been reported. We sought to identify the predictors of acute hemodynamic Tri-V responders. Acute hemodynamic studies were performed in 32 patients with advanced heart failure during Tri-V implantation. After the right ventricular (RV) and left ventricular (LV) leads were implanted for a conventional Bi-V system, an additional pacing lead was implanted in the RV outflow tract for Tri-V. The LV peak +dP/dt and tau were measured during AAI, Bi-V, and Tri-V pacing. A Tri-V responder was defined as a patient whose percentage of increase in the peak +dP/dt during Tri-V was >10% compared to of that during Bi-V. The baseline clinical variables and RV outflow tract lead location were analyzed to identify the characteristics of the Tri-V responders. Of the 32 patients, 10 (31%) were classified as Tri-V responders. The LV end-diastolic volume was greater (246 ± 48 vs 173 ± 53 ml, p <0.01), and the RV outflow tract lead was implanted at a greater outflow tract portion (p <0.05) in the Tri-V responders. Multivariate analysis revealed that only the baseline LV end-diastolic volume (per 50-ml greater) predicted the Tri-V response (odds ratio 2.87, 95% confidence interval 1.03 to 8.00, p <0.05). The area under the receiver operating characteristic curve for the LV end-diastolic volume was 0.84 (p <0.01) and an LV end-diastolic volume of >212 ml had a sensitivity of 80% and specificity of 77% to distinguish Tri-V responders. In conclusion, Tri-V provides greater hemodynamic effect for patients with a larger LV end-diastolic volume owing to its resynchronization effects on the LV anterior wall.
Collapse
|
39
|
|
40
|
Left ventricular lead position and clinical outcome in the multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) trial. Circulation 2011; 123:1159-66. [PMID: 21382893 DOI: 10.1161/circulationaha.110.000646] [Citation(s) in RCA: 409] [Impact Index Per Article: 31.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
BACKGROUND An important determinant of successful cardiac resynchronization therapy for heart failure is the position of the left ventricular (LV) pacing lead. The aim of this study was to analyze the impact of the LV lead position on outcome in patients randomized to cardiac resynchronization-defibrillation in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT) study. METHODS AND RESULTS The location of the LV lead was assessed by means of coronary venograms and chest x-rays recorded at the time of device implantation. The LV lead location was classified along the short axis into an anterior, lateral, or posterior position and along the long axis into a basal, midventricular, or apical region. The primary end point of MADIT-CRT was heart failure (HF) hospitalization or death, whichever came first. The LV lead position was assessed in 799 patients, (55% patients ≥65 years of age, 26% female, 10% LV ejection fraction ≤25%, 55% ischemic cardiomyopathy, and 71% left bundle-branch block) with a follow-up of 29±11 months. The extent of cardiac resynchronization therapy benefit was similar for leads in the anterior, lateral, or posterior position (P=0.652). The apical lead location compared with leads located in the nonapical position (basal or midventricular region) was associated with a significantly increased risk for heart failure/death (hazard ratio=1.72; 95% confidence interval, 1.09 to 2.71; P=0.019) after adjustment for the clinical covariates. The apical lead position was also associated with an increased risk for death (hazard ratio=2.91; 95% confidence interval, 1.42 to 5.97; P=0.004). CONCLUSION LV leads positioned in the apical region were associated with an unfavorable outcome, suggesting that this lead location should be avoided in cardiac resynchronization therapy. Clinical Trial Registration- URL: http://clinicaltrials.gov. Unique identifier: NCT00180271.
Collapse
|
41
|
Triple-site pacing: a new supported therapy approach for bridge to recovery with a left ventricular assist system in a patient with idiopathic dilated cardiomyopathy. J Artif Organs 2010; 13:54-7. [PMID: 20174955 DOI: 10.1007/s10047-010-0494-z] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2008] [Accepted: 01/25/2010] [Indexed: 11/25/2022]
Abstract
Left ventricular assist devices (LVAD) are widely used as bridges to cardiac transplantation or for destination therapy. LVAD support may also function as a bridge to ventricular recovery, but a sufficient rate of recovery has not been obtained, even with various adjuvant therapies. Cardiac resynchronization therapy (CRT) is an effective treatment for heart failure, and there is a report of successful weaning off LVAD with CRT. However, some patients with CRT could not improve their cardiac function because of residual dyssynchrony. Herein, we describe a case of a successful bridge to recovery with triple-site pacing for residual dyssynchrony after biventricular pacing. A 34-year-old woman with heart failure due to dilated cardiomyopathy whose condition deteriorated underwent Toyobo LVAD implantation, resulting in improvement of the left ventricular ejection fraction (LVEF) from 12 to 36%. Because of left ventricular dyssynchrony, we performed CRT, but residual dyssynchrony impeded cardiac recovery. We inserted an additional ventricular lead at the right ventricular outlet to achieve triple-site pacing in order to obtain complete synchronization. The LVEF improved to 45%, and the patient was successfully weaned off the LVAD. In LVAD-supported cases of persistent left ventricular dyssynchrony with CRT, implantation of triple-site pacing could potentially accelerate recovery.
Collapse
|
42
|
Midterm 'super-response' to cardiac resynchronization therapy by biventricular pacing with fusion: insights from electro-anatomical mapping. Europace 2009; 11:1675-82. [PMID: 19880850 PMCID: PMC2780924 DOI: 10.1093/europace/eup333] [Citation(s) in RCA: 40] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
Aims Some authors recommend avoiding fusion with left ventricular (LV) intrinsic depolarization during cardiac resynchronization therapy (CRT). If fusion is still present during optimized biventricular (Biv) pacing and its long-term effects on the response to CRT are currently unknown. The aim of the study was to analyse the endocardial LV activation pattern induced by echocardiographically optimized Biv pacing and its influence on LV reverse remodelling. Methods and results Contact electro-anatomical mapping was performed in 15 heart failure (HF) patients with left bundle branch block and echocardiographically optimized CRT (seven ischaemic aetiology, 64 ± 8 years, three women, New York Heart Association class 3 ± 0.4, LV ejection fraction 25 ± 5%). Left ventricular activation maps were performed in sinus rhythm (SR), during DDD right ventricular apical (RVA) and optimized Biv pacing. Fusion with intrinsic rhythm during pacing was considered when LV septal activation was produced at least partially by intrinsic depolarization, when compared with LV activation map during SR. Patients were considered responders to CRT if they had ≥10% reduction in LV end-systolic volume (LVESV) after 6 months of CRT. During SR, the LV breakthrough was mid-septal (n = 12), basal septum (n = 2), and apical (n = 1). During RVA pacing, LV breakthrough shifted apical in all patients. Right ventricular apical/Biv pacing proved fusion with intrinsic depolarization in 8 of 15 patients. The PR interval was shorter in patients with fusion RVA/Biv pacing (164 ± 24 vs. 234 ± 55 ms, P = 0.006). There was a trend for shorter LV activation time (LVat) in patients with fusion during RVA pacing (87 ± 33 vs. 113 ± 21 ms, P = 0.08) as well as during optimized Biv pacing (83 ± 18 vs. 104 ± 24 ms, P = 0.07), although LVat was similar in SR (100 ± 22 vs. 106 ± 20, P = NS). In patients with fusion, 6 months responder rate was significantly higher (100 vs. 28.5%, P < 0.007) as was the degree of LVESV reduction (39 ± 17 vs. 1.0 ± 14%, P < 0.001). Conclusion Biventricular pacing with fusion may substantially increase the structural responder rate probably by shortening LVat.
Collapse
|
43
|
Is bifocal right ventricular pacing a viable form of cardiac resynchronization? PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2008; 31:789-94. [PMID: 18684274 DOI: 10.1111/j.1540-8159.2008.01093.x] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
44
|
Echocardiographic Aspects of Multisite Pacing in Patients Undergoing Cardiac Resynchronization Therapy. Echocardiography 2008; 25:1056-64. [DOI: 10.1111/j.1540-8175.2008.00786.x] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
|
45
|
|
46
|
Triangle ventricular pacing in a non-responder to conventional bi-ventricular pacing. Europace 2008; 10:502-4. [DOI: 10.1093/europace/eun026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
|