Pabilona C, Gitler B, Lederman JA, Miller D, Keltz TN. Prosthetic valve endocarditis with valvular obstruction after transcatheter aortic valve replacement.
Tex Heart Inst J 2015;
42:172-4. [PMID:
25873834 DOI:
10.14503/thij-13-3961]
[Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Patients with severe aortic stenosis who are at high risk for open-heart surgery might be candidates for transcatheter aortic valve replacement (TAVR). To our knowledge, this is the first report of Streptococcus viridans endocarditis that caused prosthetic valve obstruction after TAVR. A 77-year-old man who had undergone TAVR 17 months earlier was admitted because of evidence of prosthetic valve endocarditis. A transthoracic echocardiogram revealed a substantial increase in the transvalvular peak gradient and mean gradient in comparison with an echocardiogram of 7 months earlier. A transesophageal echocardiogram showed a 1.5-cm vegetation obstructing the valve. Blood cultures yielded penicillin-sensitive S. viridans. The patient was hemodynamically stable and was initially treated with vancomycin because of his previous penicillin allergy. Subsequent therapy with levofloxacin, oral penicillin (after a negative penicillin skin test), and intravenous penicillin eliminated the symptoms of the infection. Transcatheter aortic valve replacement is a relatively new procedure, and sequelae are still being discovered. We recommend that physicians consider obstructive endocarditis as one of these.
Collapse