1
|
Hayashi K, Callahan T, Rickard J, Younis A, Baranowski B, Martin D, Nakhla S, Tabaja C, Wilkoff BL. Extraction outcomes of implantable cardioverter-defibrillator leads vary by manufacturer and model family. Europace 2023; 25:euad345. [PMID: 38000893 PMCID: PMC10751850 DOI: 10.1093/europace/euad345] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Accepted: 11/15/2023] [Indexed: 11/26/2023] Open
Abstract
AIMS Transvenous lead extraction (TLE) of implantable cardioverter-defibrillator (ICD) leads is considered challenging. The structure of each ICD leads is variable between manufacturer and model families. The net impact of lead family on the safety and effectiveness of TLE is poorly characterized. We assessed the safety and efficacy of ICD TLE and the impact of manufacturer ICD model family on the outcomes. METHODS AND RESULTS The study cohort included all consecutive patients with ICD who underwent TLE between 2013 and 2022 and are enrolled in the Cleveland Clinic Prospective TLE Registry. A total of 885 ICD leads (median implant duration 8 years) in 810 patients were included. Complete ICD TLE success was achieved in 97.2% of the leads (n = 860) and in 98.0% of the patients (n = 794). Major complications occurred in 22 patients (2.7%). Complete procedural success rate varied by manufacturer and lead family; Medtronic 98.9%, Abbott 95.9%, Boston Scientific 95.0%, Biotronik 91.2%, P = 0.03, and Linox family leads had the lowest, 89.7% P = 0.02. Multivariable predictors of incomplete ICD lead removal included ICD lead age > 10 years and Linox family lead. Multivariable predictors of major complications included ICD lead age > 15 years and longer lead extraction time, and predictors of all-cause mortality within 30 days included lead extraction for infection, end-stage renal disease, and higher New York Heart Association functional class. CONCLUSION Complete and safe ICD lead removal rate by TLE is extremely high but varied by manufacturer and lead family. Linox family lead and >10 years lead age were independent predictors of incomplete lead removal.
Collapse
Affiliation(s)
- Katsuhide Hayashi
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - Thomas Callahan
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - John Rickard
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - Arwa Younis
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - Bryan Baranowski
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - David Martin
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - Shady Nakhla
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - Chadi Tabaja
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| | - Bruce L Wilkoff
- Cardiac Electrophysiology and Pacing Section, Department of Cardiovascular Medicine, Cleveland Clinic, 9500 Euclid Avenue Desk J2-2, Cleveland, OH 44195, USA
| |
Collapse
|
2
|
Przybylowicz R, Jessel PM, Henrikson CA. Abandon one, get away mostly free, abandon two... Heart Rhythm 2023; 20:1647-1648. [PMID: 37625472 DOI: 10.1016/j.hrthm.2023.08.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/20/2023] [Accepted: 08/21/2023] [Indexed: 08/27/2023]
Affiliation(s)
- Ryle Przybylowicz
- Division of Cardiology, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon
| | - Peter M Jessel
- Division of Cardiology, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon; Division of Cardiology, Portland Veterans Administration Medical Center, Portland, Oregon
| | - Charles A Henrikson
- Division of Cardiology, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon.
| |
Collapse
|
3
|
Rexha E, Chung DU, Burger H, Ghaffari N, Madej T, Ziaukas V, Hassan K, Reichenspurner H, Gessler N, Willems S, Butter C, Pecha S, Hakmi S. Procedural outcome & risk prediction in young patients undergoing transvenous lead extraction-a GALLERY subgroup analysis. Front Cardiovasc Med 2023; 10:1251055. [PMID: 37745113 PMCID: PMC10511873 DOI: 10.3389/fcvm.2023.1251055] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 08/09/2023] [Indexed: 09/26/2023] Open
Abstract
Background The prevalence of young patients with cardiac implantable electronic devices (CIED) is steadily increasing, accompanied by a rise in the occurrence of complications related to CIEDs. Consequently, transvenous lead extraction (TLE) has become a crucial treatment approach for such individuals. Objective The purpose of this study was to examine the characteristics and procedural outcomes of young patients who undergo TLE, with a specific focus on identifying independent risk factors associated with adverse events. Methods All patients in the GALLERY (GermAn Laser Lead Extraction RegistrY) were categorized into two groups based on their age at the time of enrollment: 45 years or younger, and over 45 years. A subgroup analysis was conducted specifically for the younger population. In this analysis, predictor variables for all-cause mortality, procedural complications, and procedural failure were evaluated using multivariable analyses. Results We identified 160 patients aged 45 years or younger with a mean age of 35.3 ± 7.6 years and 42.5% (n = 68) female patients. Leading extraction indication was lead dysfunction in 51.3% of cases, followed by local infections in 20.6% and systemic infections in 16.9%. The most common device to be extracted were implantable cardioverter-defibrillators (ICD) with 52.5%. Mean number of leads per patient was 2.2 ± 1.0. Median age of the oldest indwelling lead was 91.5 [54.75-137.5] months. Overall complication rate was 3.8% with 1.9% minor and 1.9% major complications. Complete procedural success was achieved in 90.6% of cases. Clinical procedural success rate was 98.1%. Procedure-related mortality was 0.0%. The all-cause in-hospital mortality rate was 2.5%, with septic shock identified as the primary cause of mortality. Multivariable analysis revealed CKD (OR: 19.0; 95% CI: 1.84-194.9; p = 0.018) and systemic infection (OR: 12.7; 95% CI: 1.14-142.8; p = 0.039) as independent predictor for all-cause mortality. Lead age ≥ 10 years (OR: 14.58, 95% CI: 1.36-156.2; p = 0.027) was identified as sole independent risk factor for procedural complication. Conclusion TLE in young patients is safe and effective with a procedure-related mortality rate of 0.0%. CKD and systemic infection are predictors for all-cause mortality, whereas lead age ≥ 10 years was identified as independent risk factor for procedural complications in young patients undergoing TLE.
Collapse
Affiliation(s)
- Enida Rexha
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Da-Un Chung
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Heiko Burger
- Department of Cardiac Surgery, Kerckhoff Klinik, Bad Nauheim, Germany
| | - Naser Ghaffari
- Department of Cardiovascular Surgery, Helios Clinic for Heart Surgery, Karlsruhe, Germany
| | - Tomas Madej
- Department of Cardiac Surgery, University Heart Center Dresden, Dresden, Germany
| | - Virgilijus Ziaukas
- Department of Cardiac Surgery, Schüchtermann-Klinik, Bad Rothenfelde, Germany
| | - Kambiz Hassan
- Department of Cardiac Surgery, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Hermann Reichenspurner
- Department of Cardiovascular Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Hamburg/Kiel/Luebeck, Hamburg, Germany
| | - Nele Gessler
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Hamburg/Kiel/Luebeck, Hamburg, Germany
| | - Stephan Willems
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Hamburg/Kiel/Luebeck, Hamburg, Germany
| | - Christian Butter
- Department of Cardiology, Heart Center Brandenburg Bernau, Neuruppin, Germany
| | - Simon Pecha
- Department of Cardiovascular Surgery, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Samer Hakmi
- Department of Cardiac Surgery, Asklepios Klinik St. Georg, Hamburg, Germany
- DZHK (German Centre for Cardiovascular Research), Partner Site Hamburg/Kiel/Luebeck, Hamburg, Germany
| |
Collapse
|
4
|
Bracke FA, Rademakers LM, van Veghel D. Extraction of non-infected redundant pacing and defibrillator leads does not result in better patient outcomes. Neth Heart J 2023; 31:327-329. [PMID: 37010738 PMCID: PMC10444728 DOI: 10.1007/s12471-023-01770-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/09/2023] [Indexed: 04/04/2023] Open
Abstract
The introduction of dedicated tools for pacing and defibrillator lead extraction has resulted in relatively high success and low complication rates. The confidence this elicits has broadened the indications from device infections to non-functional or redundant leads and the latter make up an increasing share of extraction procedures. Proponents of extracting these leads point to the higher complication burden of lead extraction in patients with longstanding abandoned leads when compared one-to-one with extraction when these leads become redundant. However, this does not translate into better patient outcomes on a population level: complications are rare with properly abandoned leads and thus most patients will never be subjected to an extraction procedure and the ensuing complications. Therefore, not extracting redundant leads minimises the risk for the patients and avoids many expensive procedures.
Collapse
Affiliation(s)
- Frank A Bracke
- Department of Cardiology and Cardiothoracic Surgery, Catharina Hospital, Eindhoven, The Netherlands.
| | - Leonard M Rademakers
- Department of Cardiology and Cardiothoracic Surgery, Catharina Hospital, Eindhoven, The Netherlands
| | - Dennis van Veghel
- Department of Cardiology and Cardiothoracic Surgery, Catharina Hospital, Eindhoven, The Netherlands
| |
Collapse
|
5
|
Chung DU, Burger H, Kaiser L, Osswald B, Bärsch V, Nägele H, Knaut M, Reichenspurner H, Gessler N, Willems S, Butter C, Pecha S, Hakmi S. Transvenous lead extraction in patients with systemic cardiac device-related infection-Procedural outcome and risk prediction: A GALLERY subgroup analysis. Heart Rhythm 2023; 20:181-189. [PMID: 36240993 DOI: 10.1016/j.hrthm.2022.10.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/18/2022] [Revised: 09/28/2022] [Accepted: 10/03/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND Transvenous lead extraction (TLE) has evolved as one of the most crucial treatment options for patients with cardiac device-related systemic infection (CDRSI). OBJECTIVE The aim of this study was to characterize the procedural outcome and risk factors of patients with CDRSI undergoing TLE. METHODS A subgroup analysis of patients with CDRSI of the GALLERY (GermAn Laser Lead Extraction RegistrY) database was performed. Predictors for complications, procedural failure, and all-cause mortality were evaluated. RESULTS A total of 722 patients (28.6%) in the GALLERY had "systemic infection" as extraction indication. Patients with CDRSI were older (70.1 ± 12.2 years vs 67.3 ± 14.3 years; P < .001) and had more comorbidities than patients with local infections or noninfectious extraction indications. There were no differences in complete procedural success (90.6% vs 91.7%; P = .328) or major complications (2.5% vs 1.9%; P = .416) but increased procedure-related (1.4% vs 0.3%; P = .003) and all-cause in-hospital mortality (11.1% vs 0.6%; P < .001) for patients with CDRSI. Multivariate analyses revealed lead age ≥10 years as a predictor for procedural complications (odds ratio [OR] 3.23; 95% confidence interval [CI] 1.58-6.60; P = .001). Lead age ≥10 years (OR 2.57; 95% CI 1.03-6.46; P = .04) was also a predictor for procedural failure. We identified left ventricular ejection fraction <30% (OR 1.70; 95% CI 1.00-2.99; P = .049), age ≥75 years (OR 2.1; 95% CI 1.27-3.48; P = .004), chronic kidney disease (OR 1.92; 95% CI 1.17-3.14; P = .01), and overall procedural complications (OR 5.15; 95% CI 2.44-10.84; P < .001) as predictors for all-cause mortality. CONCLUSION Patients with CDRSI undergoing TLE demonstrate an increased rate of all-cause in-hospital, as well as procedure-related mortality, despite having comparable procedural success rates. Given these data, it seems paramount to develop preventive strategies to detect and treat CDRSI in its earliest stages.
Collapse
Affiliation(s)
- Da-Un Chung
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany.
| | - Heiko Burger
- Department of Cardiac Surgery, Kerckhoff Klinik, Bad Nauheim, Germany
| | - Lukas Kaiser
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Brigitte Osswald
- Division of Electrophysiological Surgery, Johanniter-Hospital Duisburg-Rheinhausen, Duisburg, Germany
| | - Volker Bärsch
- Department of Cardiology, St. Marien Krankenhaus, Siegen, Germany
| | - Herbert Nägele
- Department for Cardiac Insufficiency and Device Therapy, Albertinen-Hospital, Hamburg, Germany
| | | | - Hermann Reichenspurner
- Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg at University Hospital Hamburg-Eppendorf, Hamburg, Germany; DZHK (German Centre for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Hamburg, Germany
| | - Nele Gessler
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany; DZHK (German Centre for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Hamburg, Germany
| | - Stephan Willems
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany; DZHK (German Centre for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Hamburg, Germany
| | - Christian Butter
- Department of Cardiology, Heart Center Brandenburg Bernau, Neuruppin, Germany
| | - Simon Pecha
- Department of Cardiovascular Surgery, University Heart & Vascular Center Hamburg at University Hospital Hamburg-Eppendorf, Hamburg, Germany; DZHK (German Centre for Cardiovascular Research), partner site Hamburg/Kiel/Lübeck, Hamburg, Germany
| | - Samer Hakmi
- Department of Cardiology and Critical Care Medicine, Asklepios Klinik St. Georg, Hamburg, Germany
| |
Collapse
|
6
|
Russo V, Viani S, Migliore F, Nigro G, Biffi M, Tola G, Bisignani G, Dello Russo A, Sartori P, Rordorf R, Ottaviano L, Perego GB, Checchi L, Segreti L, Bertaglia E, Lovecchio M, Valsecchi S, Bongiorni MG. Lead Abandonment and Subcutaneous Implantable Cardioverter-Defibrillator (S-ICD) Implantation in a Cohort of Patients With ICD Lead Malfunction. Front Cardiovasc Med 2021; 8:692943. [PMID: 34395560 PMCID: PMC8356671 DOI: 10.3389/fcvm.2021.692943] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Accepted: 07/06/2021] [Indexed: 11/17/2022] Open
Abstract
Background: When an implantable-cardioverter defibrillator (ICD) lead becomes non-functional, a recommendation currently exists for either lead abandonment or removal. Lead abandonment and subcutaneous ICD (S-ICD) implantation may represent an additional option for patients who do not require pacing. The aim of this study was to investigate the outcomes of a strategy of lead abandonment and S-ICD implantation in the setting of lead malfunction. Methods: We analyzed all consecutive patients who underwent S-ICD implantation after abandonment of malfunctioning leads and compared their outcomes with those of patients who underwent extraction and subsequent reimplantation of a single-chamber transvenous ICD (T-ICD). Results: Forty-three patients underwent S-ICD implantation after abandonment of malfunctioning leads, while 62 patients underwent extraction and subsequent reimplantation of a new T-ICD. The two groups were comparable. In the extraction group, no major complications occurred during extraction, while the procedure failed and an S-ICD was implanted in 4 patients. During a median follow-up of 21 months, 3 major complications or deaths occurred in the S-ICD group and 11 in the T-ICD group (HR 1.07; 95% CI 0.29–3.94; P = 0.912). Minor complications were 4 in the S-ICD group and 5 in the T-ICD group (HR 2.13; 95% CI 0.49–9.24; P = 0.238). Conclusions: In the event of ICD lead malfunction, extraction avoids the potential long-term risks of abandoned leads. Nonetheless the strategy of lead abandonment and S-ICD implantation was feasible and safe, with no significant increase in adverse outcomes, and may represent an option in selected clinical settings. Further studies are needed to fully understand the potential risks of lead abandonment. Clinical Trial Registration: URL: ClinicalTrials.gov Identifier: NCT02275637
Collapse
Affiliation(s)
- Vincenzo Russo
- Department of Medical Translational Sciences, University of Campania "Luigi Vanvitelli", Monaldi Hospital, Naples, Italy
| | - Stefano Viani
- Second Cardiology Division, Cardio-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy
| | - Federico Migliore
- Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | - Gerardo Nigro
- Department of Medical Translational Sciences, University of Campania "Luigi Vanvitelli", Monaldi Hospital, Naples, Italy
| | - Mauro Biffi
- Institute of Cardiology, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | | | | | - Antonio Dello Russo
- Clinica di Cardiologia e Aritmologia, Università Politecnica delle Marche, Ancona, Italy
| | - Paolo Sartori
- Cardiology Division, Hospital IRCCS San Martino, Genoa, Italy
| | - Roberto Rordorf
- Department of Cardiology, Fondazione IRCCS Policlinico S. Matteo, Pavia, Italy
| | - Luca Ottaviano
- Cardiology Division, Istituto Clinico S. Ambrogio, Milan, Italy
| | | | - Luca Checchi
- Cardiology Division, University of Florence, Florence, Italy
| | - Luca Segreti
- Second Cardiology Division, Cardio-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy
| | - Emanuele Bertaglia
- Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy
| | | | | | - Maria Grazia Bongiorni
- Second Cardiology Division, Cardio-Thoracic and Vascular Department, University Hospital of Pisa, Pisa, Italy
| |
Collapse
|