1
|
Li J, Zhou G, Li X, Huang S, Lin H, Lin S, Tan L, Chen W, Huang X, Wang Y. Comparisons of procedural characteristics and clinical outcomes between SMARTTOUCH SURROUNDFLOW catheter and other catheters for atrial fibrillation radiofrequency catheter ablation: a systematic literature review. BMJ Open 2023; 13:e075579. [PMID: 37848300 PMCID: PMC10582897 DOI: 10.1136/bmjopen-2023-075579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 09/14/2023] [Indexed: 10/19/2023] Open
Abstract
BACKGROUND SMARTTOUCH SURROUNDFLOW (STSF) catheter is the new generation of SMARTTOUCH (ST) catheter with an upgraded irrigation system for radiofrequency catheter ablation (RFCA) in patients with atrial fibrillation (AF). METHODS This systematic literature review searched the major English and Chinese bibliographic databases from 2016 to 2022 for any original clinical studies assessing the STSF catheter for RFCA in AF patients. Meta-analysis with a random effects model was used for evidence synthesis. RESULTS Pooled outcomes from 19 included studies indicated that STSF catheter was associated with a significantly shorter procedure time (weighted mean difference (WMD): -17.4 min, p<0.001), shorter ablation time (WMD: -6.6 min, p<0.001) and lower catheter irrigation fluid volume (WMD: -492.7 mL, p<0.001) than ST catheter. Pooled outcomes from four included studies with paroxysmal AF patients reported that using the STSF catheter for RFCA was associated with a significantly shorter ablation time (WMD: -5.7 min, p<0.001) and a lower risk of 1-year postablation arrhythmia recurrence (rate ratio: 0.504, p<0.001) than the SURROUNDFLOW (SF) catheter. Significant reductions in procedure time and ablation time associated with the STSF catheter were also reported in the other four studies using non-ST/SF catheters as the control. Overall complications of STSF catheter and control catheters were comparable. CONCLUSIONS Using the STSF catheter was superior to using the ST catheter to conduct RFCA for AF by significantly reducing procedure time, ablation time, fluoroscopy time and irrigation fluid volume. The superiority of the STSF catheter over the SF catheter and other non-ST/SF catheters for RFCA needs further confirmation.
Collapse
Affiliation(s)
- Jianyong Li
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| | - Guifang Zhou
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| | - Xinzhong Li
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| | - Senlin Huang
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| | - Hairuo Lin
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| | - Shaopeng Lin
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| | - Liang Tan
- Changsha Normin Health Technology Ltd, Changsha, China
| | - Wendong Chen
- Normin Health Consulting Ltd, Mississauga, Ontario, Canada
- THETA Collaborative, University of Toronto, Toronto, Ontario, Canada
| | - Xiaobo Huang
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| | - Yuegang Wang
- Department of Cardioloqy, Southern Medical University Nanfang Hospital, Guangzhou, Guangdong, China
| |
Collapse
|
2
|
Costea A, Haile B, Barone A, Schenthal M, Romanowicz K, Rajsheker S, Boo LM, Hunter TD. Porous tip radiofrequency ablation catheter reduced heart failure-related complications and healthcare resource utilization in paroxysmal atrial fibrillation patients. J Arrhythm 2023; 39:352-358. [PMID: 37324763 PMCID: PMC10264747 DOI: 10.1002/joa3.12830] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 01/18/2023] [Accepted: 02/02/2023] [Indexed: 03/18/2023] Open
Abstract
Introduction A 56-hole porous tip radiofrequency catheter was developed to provide more uniform cooling with less fluid delivery than a prior 6-hole irrigated design. This study aimed to evaluate the impact of contact force (CF) ablation with the porous tip on complications (congestive heart failure [CHF] and non-CHF related), healthcare resource utilization, and procedural efficiency in patients undergoing de novo paroxysmal atrial fibrillation (PAF) ablations in a real-world setting. Methods Consecutive de novo PAF ablations were performed between February 2014 and March 2019 by six operators at a single US academic center. The 6-hole design was used through December 2016 with the 56-hole porous tip adopted in October 2016. The outcomes of interest included symptomatic CHF presentation and CHF-related complications. Results Of 174 patients who were included, mean age was 61.1 ± 10.8 years, 67.8% were male, and 25.3% had a history of CHF. Ablation with the porous tip catheter significantly decreased fluid delivery (1177 vs. 1912 mL with the 6-hole design; p < .0001). CHF-related complications within 7 days, particularly fluid overload, were substantially reduced with the porous tip (15.2% vs. 5.3% of patients; p = .0281) and the proportion of patients with symptomatic CHF presentation within 30 days postablation was significantly lower (14.7% vs. 32.5%; p = .0058). Conclusion The 56-hole porous tip led to significantly reduced CHF-related complications and healthcare utilization in PAF patients undergoing CF catheter ablation when compared to the prior 6-hole design. This reduction likely results from the significant decrease in fluid delivery during the procedure.
Collapse
Affiliation(s)
- Alexandru Costea
- Internal Medicine DepartmentUniversity of CincinnatiCincinnatiOhioUSA
| | - Bereket Haile
- College of MedicineUniversity of CincinnatiCincinnatiOhioUSA
| | - Adam Barone
- Heritage College of Osteopathic MedicineOhio UniversityAthensOhioUSA
| | | | | | | | - Lee Ming Boo
- Clinical Science and External Research, Biosense Webster, Inc.IrvineCaliforniaUSA
| | - Tina D. Hunter
- Real World Evidence, CTI Clinical Trial & ConsultingCovingtonKentuckyUSA
| |
Collapse
|
3
|
Alvarez CK, Zweibel S, Stangle A, Panza G, May T, Marieb M. Anesthetic Considerations in the Electrophysiology Laboratory: A Comprehensive Review. J Cardiothorac Vasc Anesth 2023; 37:96-111. [PMID: 36357307 DOI: 10.1053/j.jvca.2022.10.013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2022] [Revised: 10/02/2022] [Accepted: 10/10/2022] [Indexed: 11/06/2022]
Abstract
Catheter ablation procedures for arrhythmias or implantation and/or extraction of cardiac pacemakers can present many clinical challenges. It is imperative that there is clear communication and understanding between the anesthesiologist and electrophysiologist during the perioperative period regarding the mode of ventilation, hemodynamic considerations, and various procedural complications. This article provides a comprehensive narrative review of the anesthetic techniques and considerations for catheter ablation procedures, ventilatory modes using techniques such as high-frequency jet ventilation, and strategies such as esophageal deviation and luminal temperature monitoring to decrease the risk of esophageal injury during catheter ablation. Various hemodynamic considerations, such as the intraprocedural triaging of cardiac tamponade and fluid administration during catheter ablation, also are discussed. Finally, this review briefly highlights the early research findings on pulse-field ablation, a new and evolving ablation modality.
Collapse
Affiliation(s)
- Chikezie K Alvarez
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; University of Connecticut, Farmington, CT.
| | - Steven Zweibel
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT
| | - Alexander Stangle
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; University of Connecticut, Farmington, CT
| | - Gregory Panza
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; University of Connecticut, Farmington, CT
| | - Thomas May
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT
| | - Mark Marieb
- Hartford HealthCare Heart and Vascular Institute, Hartford, CT; Griffin Hospital, Derby, CT
| |
Collapse
|
4
|
Procedural Efficiency, Efficacy, and Safety of High-Power, Short-Duration Radiofrequency Ablation Delivered by STSF Catheter for Paroxysmal Atrial Fibrillation. EVIDENCE-BASED COMPLEMENTARY AND ALTERNATIVE MEDICINE 2022; 2022:6009275. [PMID: 35979002 PMCID: PMC9377865 DOI: 10.1155/2022/6009275] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Revised: 07/04/2022] [Accepted: 07/14/2022] [Indexed: 11/17/2022]
Abstract
Objectives To investigate the procedural efficiency, efficacy, and safety of high-power, short-term radiofrequency ablation delivered by the SmartTouch Surround Flow (STSF) catheter for paroxysmal atrial fibrillation (AF). Methods We retrospectively analyzed a total of 72 patients who were admitted with paroxysmal AF, and who underwent radiofrequency catheter ablation (RFCA) for the first time. Of these patients, 36 cases underwent low-power, long-duration (LPLD, (30–35 W/20–40 s) pulmonary vein isolation (PVI) delivered by an SmartTouch (ST) catheter (control group), and the other 36 cases underwent high-power, short-duration (HPSD, (45–50 W/10–20 s) PVI delivered by a STSF catheter (study group). The baseline data, duration of PVI, procedural time, fluoroscopy time, the rate of first-pass isolation, irrigation perfusion, eschar and steam pop occurrences, intraoperative complications, and the rate of stable sinus rhythm maintenance following a blanking period of three months were analyzed between the two groups. Results The isolation time of bilateral PVI and procedural time in the study group were markedly less than in controls (p < 0.01). The rate of first-pass isolation in the study group was significantly higher than in the control group (95.8% vs. 84.7%, p = 0.023), while the fluid perfusion in the study group was approximately 20% less than that in the control group (767 ± 171 vs. 966 ± 227 ml, p < 0.001). We observed no severe complications in any patients. The rate of freedom from AF recurrences following a blanking period of three months showed a tendency to be higher than in controls (93.9% vs. 87.1%, p = 0.348). Conclusions The HPSD strategy delivered by the STSF catheter was superior to conventional LPLD ablation through the ST catheter with respect to efficiency, acute procedural effectiveness, short-term safety, and the risk of heart failure in patients with paroxysmal AF.
Collapse
|
5
|
Comparison of two catheters measuring local impedance: local impedance variation vs lesion characteristics and steam pops. J Interv Card Electrophysiol 2022; 65:419-428. [PMID: 35438394 DOI: 10.1007/s10840-022-01214-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 03/31/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE The size of the distal electrode and the method of measuring local impedance (LI) are different between the IntellaNav MiFi-OI™ (MiFi-OI) and IntellaNav STABLE POINT™ (SP) catheters. We investigated the impact of these differences on LI, efficacy, and safety of radiofrequency (RF) applications. METHODS RF applications at a range of powers (30 W, 40 W, and 50 W), contact forces (10 g and 20 g), and durations (10-120 s) were performed in excised porcine hearts (N = 48). LI variation was defined by δLI-drop (= initial LI - post-RF LI) and %LI-drop (= δLI-drop/initial LI) × 100, and the relationship between lesion characteristics and LI variation was compared. RESULTS A total of 576 lesions were examined. Although absolute δLI-drop during RF applications was significantly larger for the SP than MiFi-OI catheter (47[31-65]ohm for SP vs 37[24-51]ohm for MiFi-OI, p < 0.0001), %LI-drop was similar (23.3 [15.5-30.6]% in SP vs 24.9[17.3-32.5]% in MiFi-OI, p = 0.10). Although lesions produced by both catheters were similarly correlated with LI variation, the SP catheter produced generally larger lesions (depth; 5.0 [3.7-6.1]mm vs 4.7 [3.3-6.0]mm, p = 0.06; surface areas, 46.9 [36.8-58.8]mm2 vs 44.7 [34.3-55.5]mm2, p = 0.02; volume, 321 [165-533]mm3 vs 265[141-471]mm3, p = 0.02). Steam pops were similarly observed with both catheters. In both catheters, %LI-drop was superior to δLI-drop in correlation to lesion size (p < 0.0001) and in predicting steam pops (p < 0.01). CONCLUSIONS Although no difference in safety profile is observed between MiFi-OI and SP catheters, the SP catheter produces larger lesions. %LI-drop is superior to δLI-drop in correlation to lesion size and in predicting steam pops as well as in normalizing the difference between catheters.
Collapse
|
6
|
Gallagher MM, Yi G, Gonna H, Leung LWM, Harding I, Evranos B, Bastiaenen R, Sharma R, Wright S, Norman M, Zuberi Z, Camm AJ. Multi-catheter cryotherapy compared with radiofrequency ablation in long-standing persistent atrial fibrillation: a randomized clinical trial. Europace 2021; 23:370-379. [PMID: 33188692 DOI: 10.1093/europace/euaa289] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Accepted: 09/04/2020] [Indexed: 11/14/2022] Open
Abstract
AIMS Restoring sinus rhythm (SR) by ablation alone is an endpoint used in radiofrequency (RF) ablation for long-standing persistent atrial fibrillation (AF) but not with cryotherapy. The simultaneous use of two cryotherapy catheters can improve ablation efficiency; we compared this with RF ablation in chronic persistent AF aiming for termination to SR by ablation alone. METHODS AND RESULTS Consecutive patients undergoing their first ablation for persistent AF of >6 months duration were screened. A total of 100 participants were randomized 1:1 to multi-catheter cryotherapy or RF. For cryotherapy, a 28-mm Arctic Front Advance was used in tandem with focal cryoablation catheters. Open-irrigated, non-force sensing catheters were used in the RF group with a 3D mapping system. Pulmonary vein (PV) isolation and non-PV triggers were targeted. Participants were followed up at 6 and 12 months, then yearly. Acute PVI was achieved in all cases. More patients in the multi-catheter cryotherapy group were restored to SR by ablation alone, with a shorter procedure duration. Sinus rhythm continued to the last available follow-up in 16/49 patients (33%) in the multi-catheter at 3.0 ± 1.6 years post-ablation and in 12/50 patients (24%) in the RF group at 4.0 ± 1.2 years post-ablation. The yearly rate of arrhythmia recurrence was similar. CONCLUSION Multi-catheter cryotherapy can restore SR by ablation alone in more cases and more quickly than RF ablation. Long-term success is difficult to achieve by either methods and is similar with both.
Collapse
Affiliation(s)
- Mark M Gallagher
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Gang Yi
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Hanney Gonna
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Lisa W M Leung
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Idris Harding
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Banu Evranos
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Rachel Bastiaenen
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Rajan Sharma
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Sue Wright
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Mark Norman
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - Zia Zuberi
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| | - A John Camm
- Cardiology Clinical Academic Group, St. George's University Hospitals NHS Foundation Trust, St. George's University of London, Blackshaw Road, London SW17 0QT, UK
| |
Collapse
|
7
|
Mehta N, Morgaenko K, Sauer W, Stevenson W, Haines D. Impact of Variableorientation and Flow Rates on Radiofrequency Ablation Lesions Created by Externally Irrigated Catheters: An Ex-Vivo Study. J Atr Fibrillation 2020; 13:2353. [PMID: 34950307 DOI: 10.4022/jafib.2353] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2020] [Revised: 06/03/2020] [Accepted: 07/09/2020] [Indexed: 11/10/2022]
Abstract
The impact of variability in irrigation rates and catheter orientation on radiofrequency ablation (RF) lesion creation has not been studied systematically for the uniformly irrigated 56-pore (56P) catheter. This study aimed to analyze the impact of irrigation flow rates (IFRs) and catheter orientation (CO) settings on RF lesions sizes produced by a 56P irrigation catheter in a power-controlled mode using an ex-vivo model. RF lesions were created in strips of chicken muscle in a saline bath heated to 37°C with 56P and 6P catheters using low flow rate (LFR) at 2 cc/min and standard flow (SFR) irrigation rates at 8 cc/min for 56P and 17 cc/min for 6P with horizontal (HO) and vertical (VO) catheter orientations. Ablation power of 20W was delivered for 30 seconds with a mean contact force of 10 g. Sixty RF lesions were analyzed. For the 56P catheter, in contrast to the 6P catheter lesion geometry was independent of CO and IFR in our model. Although 6P catheter had slightly deeper lesions, the overall lesion volumes were similar for 6P and 56P catheters. CO and IFR appeared to have minimal impact on lesion volume creation with 56P catheter. In head-to-head comparison the 6P and 56P irrigated catheters performed similarly.
Collapse
Affiliation(s)
- Nishaki Mehta
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia
| | - Katerina Morgaenko
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia
| | - William Sauer
- Brigham and Women's Hospital, Boston, Massachusetts, Vanderbilt Health System, Nashville, Tennessee
| | - William Stevenson
- Division of Cardiovascular Medicine, University of Virginia Health System, Charlottesville, Virginia.,Brigham and Women's Hospital, Boston, Massachusetts, Vanderbilt Health System, Nashville, Tennessee.,Beaumont Hospital, Oakland University of Medicine, Michigan
| | - David Haines
- Beaumont Hospital, Oakland University of Medicine, Michigan
| |
Collapse
|
8
|
Right Ventricular Electrogram Characteristics in a T1 Mapping-Validated Normal Population. JACC Clin Electrophysiol 2020; 6:711-721. [DOI: 10.1016/j.jacep.2019.12.011] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 11/26/2019] [Accepted: 12/19/2019] [Indexed: 11/20/2022]
|
9
|
Contact force sensing in ablation of ventricular arrhythmias using a 56-hole open-irrigation catheter: a propensity-matched analysis. J Interv Card Electrophysiol 2020; 60:543-553. [PMID: 32440943 PMCID: PMC8134314 DOI: 10.1007/s10840-020-00756-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/06/2020] [Accepted: 03/25/2020] [Indexed: 11/18/2022]
Abstract
Purpose The effect of adding contact force (CF) sensing to 56-hole tip irrigation in ventricular arrhythmia (VA) ablation has not been previously studied. We aimed to compare outcomes with and without CF sensing in VA ablation using a 56-hole radiofrequency (RF) catheter. Methods A total of 164 patients who underwent first-time VA ablation using Thermocool SmartTouch Surround Flow (TC-STSF) catheter (Biosense-Webster, Diamond Bar, CA, USA) were propensity-matched in a 1:1 fashion to 164 patients who had first-time ablation using Thermocool Surround Flow (TC-SF) catheter. Patients were matched for age, gender, cardiac aetiology, ejection fraction and approach. Acute success, complications and long-term follow-up were compared. Results There was no difference between procedures utilising either TC-SF or TC-STSF in acute success (TC-SF: 134/164 (82%), TC-STSF: 141/164 (86%), p = 0.3), complications (TC-SF: 11/164 (6.7%), TC-STSF: 11/164 (6.7%), p = 1.0) or VA-free survival (TC-SF: mean arrhythmia-free survival time = 5.9 years, 95% CI = 5.4–6.4, TC-STSF: mean = 3.2 years, 95% CI = 3–3.5, log-rank p = 0.74). Fluoroscopy time was longer in normal hearts with TC-SF (19 min, IQR: 14–30) than TC-STSF (14 min, IQR: 8–25; p = 0.04). Conclusion Both TC-SF and TC-STSF catheters are safe and effective in treating VAs. The use of CF sensing catheters did not improve safety or acute and long-term outcomes, but reduced fluoroscopy time in normal heart VA.
Collapse
|
10
|
Chen CF, Gao XF, Liu MJ, Jin CL, Xu YZ. Safety and efficacy of the ThermoCool SmartTouch SurroundFlow catheter for atrial fibrillation ablation: A meta-analysis. Clin Cardiol 2019; 43:267-274. [PMID: 31743474 PMCID: PMC7068067 DOI: 10.1002/clc.23297] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 11/01/2019] [Accepted: 11/07/2019] [Indexed: 12/22/2022] Open
Abstract
Background The ThermoCool Smarttouch Surroundflow catheter (STSFc) is an advanced catheter, which integrating contact force sensing and surroundflow technology. However, comparative data between STSFc and contact force sensing catheter (Thermocool SmartTouch catheter [STc]) are limited. Hypothesis We thought that STSFc might bring more clinical benefits. The aim of this meta‐analysis was to compare the safety and efficiency between the STSFc and the STc for treatment of atrial fibrillation (AF). Methods The Medline, PubMed, Embase, and Cochrane Library databases were searched for studies comparing STSFc and STc. Results Four trials involving 727 patients were included in the study. Pool‐analyses demonstrated that, as compared STc ablation, STSFc ablation was more beneficial in terms of procedural times (standard mean difference [SMD]: −0.22; 95% confidence interval [CI], −0.37 to −0.07, P = .005) and irrigation fluid volume (SMD: −1.94; 95% CI, −2.65 to −1.22, P < .0001). There was no significant difference between STSFc and STc (risk ratio [RR]: 1.02; 95% CI: 0.86 to 1.21, P = .79) for free from AF. Evidence of complications were low and similar for both groups (RR: 0.83; 95% CI: 0.19‐3.55, P = .80). Additionally, patients administered STSFc ablation tended to have shorter fluoroscopic times (SMD: −0.20; 95% CI, −0.63‐0.23, P = .21). Conclusions STSFc ablation was associated with reducing procedural times and irrigation fluid volume. Further, STSFc ablation tended to shorten fluoroscopic times. Therefore, STSFc ablation would be a better choice for AF patients especially in patients with heart failure.
Collapse
Affiliation(s)
- Chao-Feng Chen
- Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou City, Zhejiang Province, China
| | - Xiao-Fei Gao
- Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou City, Zhejiang Province, China
| | - Mei-Jun Liu
- Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou City, Zhejiang Province, China
| | - Chao-Lun Jin
- Nanjing Medical University, Hangzhou City, Zhejiang Province, China
| | - Yi-Zhou Xu
- Hangzhou First People's Hospital, Zhejiang University School of Medicine, Hangzhou City, Zhejiang Province, China
| |
Collapse
|
11
|
Porous tip contact force–sensing catheters for pulmonary vein isolation: performance in a clinical routine setting. J Interv Card Electrophysiol 2019; 57:251-259. [DOI: 10.1007/s10840-019-00591-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 07/10/2019] [Indexed: 01/09/2023]
|
12
|
Solimene F, Lepillier A, Ruvo E, Scaglione M, Anselmino M, Sebag FA, Pecora D, Gallagher MM, Rillo M, Viola G, Rossi L, Santis V, Landolina M, Castro A, Grimaldi M, Badenco N, Del Greco M, Simone A, Bertaglia E, Stabile G. Reproducibility of acute pulmonary vein isolation guided by the ablation index. PACING AND CLINICAL ELECTROPHYSIOLOGY: PACE 2019; 42:874-881. [DOI: 10.1111/pace.13710] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/16/2019] [Revised: 04/16/2019] [Accepted: 04/27/2019] [Indexed: 10/26/2022]
Affiliation(s)
| | | | | | | | | | | | | | | | | | | | - Luca Rossi
- Ospedale Civili Guglielmo da Saliceto Piacenza Italy
| | | | | | | | | | | | | | | | - Emanuele Bertaglia
- Department of Cardiac, Thoracic, and Vascular SciencesUniversity of Padova Italy
| | - Giuseppe Stabile
- Clinica Montevergine Mercogliano (AV) Italy
- Clinica San Michele Maddaloni (CE) Italy
| |
Collapse
|
13
|
Zei PC, Hunter TD, Gache LM, O'Riordan G, Baykaner T, Brodt CR. Low-fluoroscopy atrial fibrillation ablation with contact force and ultrasound technologies: a learning curve. Pragmat Obs Res 2019; 10:1-7. [PMID: 30666175 PMCID: PMC6330962 DOI: 10.2147/por.s181220] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/03/2022] Open
Abstract
Background Fluoroscopy exposure during catheter ablation is a health hazard to patients and operators. This study presents the results of implementing a low-fluoroscopy workflow using modern contact force (CF) technologies in paroxysmal atrial fibrillation (PAF) ablation. Methods A fluoroscopy reduction workflow was implemented and subsequent catheter ablations for PAF were evaluated. After vascular access with ultrasound guidance, a THERMOCOOL SMARTTOUCH® Catheter (ST) was advanced into the right atrium. The decapolar catheter was placed without fluoroscopy. A double-transseptal puncture was performed under intracardiac echocardiography guidance. ST and mapping catheters were advanced into the left atrium. A left atrial map was created, and pulmonary vein (PV) isolation was confirmed via entrance and exit block before and after the administration of isoproterenol or adenosine. Results Forty-three patients underwent PAF ablation with fluoroscopy reduction workflow (mean age: 66±9 years; 70% male), performed by five operators. Acute success rate (PV isolation) was 96.5% of PVs. One case of pericardial effusion, not requiring intervention, was the only acute complication. Mean procedure time was 217±42 minutes. Mean fluoroscopy time was 2.3±3.0 minutes, with 97.7% of patients having < 10 minutes and 86.0% having < 5 minutes. A significant downward trend over time was observed, suggesting a rapid learning curve for fluoroscopy reduction. Freedom from any atrial arrhythmias without reablation was 80.0% after a mean follow-up of 12±3 months. Conclusion Low fluoroscopy time is achievable with CF technologies after a short learning curve, without compromising patient safety or effectiveness.
Collapse
Affiliation(s)
- Paul C Zei
- Cardiac Electrophysiology, Brigham and Women's Hospital, Boston, MA, USA
| | - Tina D Hunter
- Real World Evidence, CTI Clinical Trial and Consulting Services, Covington, KY, USA,
| | - Larry M Gache
- Real World Evidence, CTI Clinical Trial and Consulting Services, Covington, KY, USA,
| | - Gerri O'Riordan
- Cardiovascular Medicine, Stanford University, Stanford, CA, USA
| | - Tina Baykaner
- Cardiovascular Medicine, Stanford University, Stanford, CA, USA
| | - Chad R Brodt
- Cardiovascular Medicine, Stanford University, Stanford, CA, USA
| |
Collapse
|
14
|
Maurer T, Rottner L, Makimoto H, Reissmann B, Heeger CH, Lemes C, Fink T, Riedl J, Santoro F, Wohlmuth P, Volkmer M, Mathew S, Metzner A, Ouyang F, Kuck KH, Sohns C. The best of two worlds? Pulmonary vein isolation using a novel radiofrequency ablation catheter incorporating contact force sensing technology and 56-hole porous tip irrigation. Clin Res Cardiol 2018; 107:1003-1012. [PMID: 29740700 DOI: 10.1007/s00392-018-1270-y] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/04/2018] [Accepted: 05/02/2018] [Indexed: 10/17/2022]
Abstract
AIMS This study aimed to evaluate feasibility and safety as well as 1-year clinical outcome of pulmonary vein isolation (PVI) using a unique radiofrequency ablation catheter ("Thermocool SmartTouch SurroundFlow"; STSF) incorporating both, contact force (CF) sensing technology and enhanced tip irrigation with 56 holes, in one device. METHODS A total of 110 patients suffering from drug-refractory atrial fibrillation underwent wide area circumferential PVI using either the STSF ablation catheter (75 consecutive patients, study group) or a CF catheter with conventional tip irrigation ("Thermocool SmartTouch", 35 consecutive patients, control group). For each ablation lesion, a target CF of ≥ 10-39 g and a force time integral (FTI) of > 400 g s was targeted. RESULTS Acute PVI was achieved in all patients with target CF obtained in > 85% of ablation points when using either device. Mean procedure time (131.3 ± 33.7 min in the study group vs. 133.0 ± 42.0 min in the control group; p = 0.99), mean fluoroscopy time (14.0 ± 6 vs. 13.5 ± 6.6 min; p = 0.56) and total ablation time were not significantly different (1751.0 ± 394.0 vs. 1604.6 ± 287.8 s; p = 0.2). However, there was a marked reduction in total irrigation fluid delivery by 51.7% (265.52 ± 64.4 vs. 539.6 ± 118.2 ml; p < 0.01). The Kaplan-Meier estimate 12-month arrhythmia-free survival after the index procedure following a 3-month blanking period was 79.9% (95% CI 70.4%, 90.4%) for the study group and 66.7% for the control group (95% CI 50.2%, 88.5%). This finding did not reach statistical significance (p = 0.18). Major complications occurred in 2/75 patients (2.7%; one pericardial tamponade and one transient ischemic attack) in the study group and no patient in the control group (p = 18). CONCLUSION PVI using the STSF catheter is safe and effective and results in beneficial 1-year clinical outcome. The improved tip irrigation leads to a significant reduction in procedural fluid burden.
Collapse
Affiliation(s)
- Tilman Maurer
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany.
| | - Laura Rottner
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Hisaki Makimoto
- Department of Cardiology, Universitätsklinikum Düsseldorf, Düsseldorf, Germany
| | - Bruno Reissmann
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Christian-H Heeger
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany.,Department of Cardiology, Universitätsklinik Lübeck, Lübeck, Germany
| | - Christine Lemes
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Thomas Fink
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Johannes Riedl
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Francesco Santoro
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Peter Wohlmuth
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Marius Volkmer
- Electrophysiology Bremen, Heart Center Bremen, Klinikum Links der Weser, Bremen, Germany
| | - Shibu Mathew
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Andreas Metzner
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Feifan Ouyang
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Karl-Heinz Kuck
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany
| | - Christian Sohns
- Department of Cardiology, Asklepios Klinik St. Georg, Hamburg, Germany.,Electrophysiology Bremen, Heart Center Bremen, Klinikum Links der Weser, Bremen, Germany
| |
Collapse
|
15
|
Maurer T, Kuck KH. The quest for durable lesions in catheter ablation of atrial fibrillation - technological advances in radiofrequency catheters and balloon devices. Expert Rev Med Devices 2017; 14:621-631. [PMID: 28723304 DOI: 10.1080/17434440.2017.1358086] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION Atrial fibrillation is the most common cardiac arrhythmia and represents a growing clinical, social and economic challenge. Catheter ablation for symptomatic atrial fibrillation has evolved from an experimental procedure into a widespread therapy and offers a safe and effective treatment option. A prerequisite for durable PVI are transmural and contiguous circumferential lesions around the pulmonary veins. However, electrical reconnection of initially isolated pulmonary veins remains a primary concern and is a dominant factor for arrhythmia recurrence during long-term follow up. Areas covered: This article discusses the physiology of lesion formation using radiofrequency-, cryo- or laser- energy for pulmonary vein isolation and provides a detailed review of recent technological advancements in the field of radiofrequency catheters and balloon devices. Finally, future directions and upcoming developments for the interventional treatment of atrial fibrillation are discussed. Expert commentary: Durable conduction block across deployed myocardial lesions is mandatory not only for PVI but for any other cardiac ablation strategy as well. A major improvement urgently expected is the intraprocedural real-time distinction of durable lesions from interposed gaps with only transiently impaired electrical conduction. Furthermore, a simplification of ablation tools used for PVI is required to reduce the high technical complexity of the procedure.
Collapse
Affiliation(s)
- Tilman Maurer
- a Department of Cardiology , Asklepios Klinik St. Georg , Hamburg , Germany
| | - Karl-Heinz Kuck
- a Department of Cardiology , Asklepios Klinik St. Georg , Hamburg , Germany
| |
Collapse
|