1
|
Lu C, Wang H, Yang P, Liu Y, Zhang Y, Xu Z, Xie Y, Hu J. Early Results of the Newly-Designed Flowdynamics Dense Mesh Stent for Residual Dissection After Proximal Repair of Stanford Type A or Type B Aortic Dissection: A Preliminary Single-Center Report From a Multicenter, Prospective, and Randomized Study. J Endovasc Ther 2024; 31:984-994. [PMID: 36978288 DOI: 10.1177/15266028231163057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/30/2023]
Abstract
BACKGROUND Negative remodeling of the distal aorta due to residual dissection significantly impacts the long-term outcomes of dissection patients after proximal repair of acute aortic dissection. Branched/fenestrated aortic stents are technically demanding, and studies of the first generation of multilayer flow modulators for tackling this clinical scenario are few and limited. The single-center results from a multicenter, prospective, and randomized controlled study aimed to verify the safety and effectiveness of a newly-designed flowdynamics dense mesh stent for treating residual dissection after proximal repair. METHODS Patients with nonchronic residual dissection involving visceral branches were prospectively enrolled in 3 centers (ChiCTR1900023638). Eligible patients were randomly assigned to the flowdynamics dense mesh stent (FDMS) group and control group. Follow-up visits were arranged at 1, 3, 6, and 12 months after recruitment. The primary endpoints were all-cause and aortic-related mortality. The secondary endpoints included visceral branch occlusion, reintervention, and severe adverse events. Morphological changes were analyzed to exhibit the therapeutic effect. Our center participated in the multicenter prospective randomized controlled trial, and the preliminary single-center experience was reported. RESULTS Thirty-six patients were enrolled in our center, and the baseline characteristics of the 2 groups were comparable. Thirty-four patients completed the 12 month follow-up. Freedom from all-cause and aortic-related death were 94.4% and 100%. All visceral branches remained patent in the FDMS group. Increased area of the true lumen (1.03±0.38 vs 0.48±0.63 cm2 at the plane below renal arteries, p=0.006; 1.27±0.80 vs 0.32±0.50 cm2 at the plane 5 cm below renal arteries, p<0.001) and decreased area of the false lumen at the plane below renal arteries (-1.03±0.84 vs -0.15±1.21 cm2, p=0.023) were observed in the FDMS group compared with those parameters in the control group. The FDMS group showed a significant increase in true lumen volume (p<0.001) and a significant decrease in false lumen volume (p=0.018). CONCLUSIONS This newly-designed FDMS for endovascular repair of residual dissection after the proximal repair is safe and effective at 12 months. CLINICAL IMPACT One-year results of the randomized controlled clinical trial indicated the short-term safety and promising effect of FDMS on treating non-chronic residual dissection after proximal repair. At the 12th-month follow-up, the true lumen expanded, the false lumen shrunk and all visceral arteries kept patent. As far as I'm concerned, this is the first randomized controlled study concerning utilizing multilayer flow mesh stent treating aortic dissection. Despite a preliminary single-center report, our results are supposed to provide high-quality evidence to guide clinical practice and fill the gap in the application of FDMS.
Collapse
Affiliation(s)
- Chen Lu
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Haiyue Wang
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Peng Yang
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Yu Liu
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Yu Zhang
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Zhenyuan Xu
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Yi Xie
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
| | - Jia Hu
- Department of Cardiovascular Surgery, West China Hospital, Sichuan University, Chengdu, People's Republic of China
- Department of Cardiothoracic Surgery, Guang'an Hospital, West China Hospital, Sichuan University, Guang'an, People's Republic of China
| |
Collapse
|
2
|
Bontinis V, Antonopoulos CN, Bontinis A, Sfyroeras GS, Kontopodis N, Ioannou CV, Ktenidis K, Geroulakos G. A systematic review and meta-analysis of the streamliner multilayer flow modulator stent for treatment of complex aortic lesions. J Vasc Surg 2021; 74:646-656.e9. [PMID: 34019986 DOI: 10.1016/j.jvs.2021.03.031] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 03/14/2021] [Indexed: 11/24/2022]
Abstract
OBJECTIVE We evaluated the safety and efficacy of multilayer flow modulator (MFM) stents (Cardiatis, Isnes, Belgium) for the treatment of complex aortic lesions. METHODS A systematic electronic research was conducted for studies reported from December 2008 to May 2020. Data extracted from 15 eligible case series (CS) were appropriately pooled and analyzed in a meta-analysis. The patient baseline characteristics were recorded, and 16 outcomes of interest were studied. The primary end points included 30-day all-cause and aneurysm-related mortality, aneurysm-related mortality at 1 year, vessel patency, and any endoleaks, ruptures, reinterventions, and aneurysm exclusion at the end of follow-up. RESULTS A total of 39 studies (15 CS and 24 case reports), involving 429 patients, met the inclusion criteria. Overall, 436 lesions were treated, and 1521 aortic branches were covered by the multilayer stent. The mean follow-up for the 15 CS with 404 patients was 14.6 months. Compliance with the instructions for use was reported by eight CS, with 75% of the procedures performed within the instructions for use. However, 41% of the patients reported by 12 CS had undergone a previous aortic intervention. The pooled 30-day all-cause and 30-day aneurysm-related mortality rates were 0.56% (95% confidence interval [CI], 0.00%-2.54%) and 0.00% (95% CI, 0.00%-0.80%), respectively. The pooled aneurysm-related mortality at 1 year of follow-up was 5.25% (95% CI, 0.07%-14.91%). The pooled vessel patency at the end of follow-up was 99.12% (95% CI, 97.73%-99.93%). The pooled reintervention and endoleak rates at the end of follow-up were 10.94% (95% CI, 3.64%-20.67%) and 10.70% (95% CI, 4.45%-18.66%), respectively. The crude spinal cord ischemia and renal failure rates were 0.69% and 1.8%, respectively. CONCLUSIONS The results from the present review and meta-analysis have indicated the safety and efficacy of MFM stents for treating challenging aortic pathologic lesions when used as first-line treatment and within the instructions for use. The almost zero pooled 30-day all-cause and aneurysm-related mortality rates combined with the low crude spinal cord ischemia and renal failure rates indicate the use of MFM stents is a good treatment option for complex aortic lesions in the short- and mid-term periods. The lack of long-term follow-up warrants further research concerning the efficacy of the device in the long term.
Collapse
Affiliation(s)
- Vangelis Bontinis
- Department of Vascular Surgery, Aristotle University of Thessaloniki, AHEPA University General Hospital, Thessaloniki, Greece.
| | - Constantine N Antonopoulos
- Department of Vascular Surgery, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Alkis Bontinis
- Department of Vascular Surgery, Aristotle University of Thessaloniki, AHEPA University General Hospital, Thessaloniki, Greece
| | - George S Sfyroeras
- Department of Vascular Surgery, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| | - Nikolaos Kontopodis
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion, University of Crete Medical School, Heraklion, Greece
| | - Christos V Ioannou
- Vascular Surgery Unit, Department of Cardiothoracic and Vascular Surgery, University Hospital Heraklion, University of Crete Medical School, Heraklion, Greece
| | - Kiriakos Ktenidis
- Department of Vascular Surgery, Aristotle University of Thessaloniki, AHEPA University General Hospital, Thessaloniki, Greece
| | - George Geroulakos
- Department of Vascular Surgery, National and Kapodistrian University of Athens, Attikon University Hospital, Athens, Greece
| |
Collapse
|
3
|
Costache VS, Meekel JP, Costache A, Melnic T, Bucurenciu C, Chitic A, Candea G, Solomon C, Yeung KK. One-Year Single-Center Results of the Multilayer Flow Modulator Stents for the Treatment of Type B Aortic Dissection. J Endovasc Ther 2020; 28:20-31. [PMID: 32873130 PMCID: PMC7816551 DOI: 10.1177/1526602820950720] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Purpose To report a single-center series of patients with type B aortic dissection treated with the Multilayer Flow Modulator (MFM). Materials and Methods Over a 36-month period, 23 patients (median age 53 years; 20 men) with complicated type B aortic dissections (2 acute, 5 subacute, and 16 chronic) were treated with the MFM. Primary endpoints of rupture or dissection-related death, overall mortality, and reintervention were evaluated using the Kaplan-Meier method; estimates for freedom from the endpoints are reported with the 95% confidence interval (CI). Secondary outcomes included technical success, adverse events, and aortic remodeling. Clinical and imaging data were collected preoperatively, directly postoperatively, and annually to 36 months for analysis using computational fluid dynamics (CFD). Results Initial technical success was 91.3%. The estimates of the endpoints at 12 months were 100% for freedom from rupture or aortic-related death, 95.7% for freedom from overall mortality, and 91.3% for freedom from reintervention. No device-related neurological or systemic complications occurred, and no additional reinterventions were needed during follow-up. A total of 144 branches overstented by the MFM remained patent. Morphologic analysis of the aortic dissection showed progressive true lumen volume increase (75.9%, p<0.001) with concomitant false lumen volume decrease (42.8%, p<0.001); the CFD analyses showed increased laminar flow. Conclusion In the current series, the MFM provided a safe and feasible treatment option for complicated acute, subacute, and chronic type B aortic dissections, with high technical success, low mortality, and active aortic remodeling. Further studies should elucidate the long-term safety of the MFM and its effectiveness in a larger patient cohort.
Collapse
Affiliation(s)
- Victor S Costache
- NEXTcardio Project, Lucian Blaga University, Sibiu, Romania.,Cardiovascular Department, Polisano European Hospital, Sibiu, Romania
| | - Jorn P Meekel
- NEXTcardio Project, Lucian Blaga University, Sibiu, Romania.,Department of Vascular Surgery, Amsterdam University Medical Centers, Amsterdam, the Netherlands.,Department of Surgery, Zaans Medisch Centrum, Zaandam, the Netherlands.,Amsterdam Cardiovascular Sciences, VU University Medical Center Amsterdam, the Netherlands
| | - Andreea Costache
- NEXTcardio Project, Lucian Blaga University, Sibiu, Romania.,Cardiovascular Department, Polisano European Hospital, Sibiu, Romania
| | - Tatiana Melnic
- NEXTcardio Project, Lucian Blaga University, Sibiu, Romania.,Cardiovascular Department, Polisano European Hospital, Sibiu, Romania
| | | | - Anca Chitic
- NEXTcardio Project, Lucian Blaga University, Sibiu, Romania.,Cardiovascular Department, Polisano European Hospital, Sibiu, Romania
| | | | - Crina Solomon
- NEXTcardio Project, Lucian Blaga University, Sibiu, Romania
| | - Kak K Yeung
- NEXTcardio Project, Lucian Blaga University, Sibiu, Romania.,Department of Vascular Surgery, Amsterdam University Medical Centers, Amsterdam, the Netherlands.,Amsterdam Cardiovascular Sciences, VU University Medical Center Amsterdam, the Netherlands
| |
Collapse
|
4
|
Sultan S, Acharya Y, Hynes N. Commentary: When Promising Innovators Lack Strategic Vision: The Concept of Flow Modulation in Aortic Dissection. J Endovasc Ther 2020; 28:32-35. [DOI: 10.1177/1526602820954450] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Sherif Sultan
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University Hospital Galway, National University of Ireland, Galway, Ireland
- Department of Vascular and Endovascular Surgery, Galway Clinic, Doughiska, Royal College of Surgeons in Ireland, and National University of Ireland, Galway Affiliated Hospital, Galway, Ireland
| | - Yogesh Acharya
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University Hospital Galway, National University of Ireland, Galway, Ireland
- Department of Vascular and Endovascular Surgery, Galway Clinic, Doughiska, Royal College of Surgeons in Ireland, and National University of Ireland, Galway Affiliated Hospital, Galway, Ireland
| | - Niamh Hynes
- Department of Vascular and Endovascular Surgery, Galway Clinic, Doughiska, Royal College of Surgeons in Ireland, and National University of Ireland, Galway Affiliated Hospital, Galway, Ireland
| |
Collapse
|