1
|
Dziadosz M. Direct analysis of ethylene glycol in human serum on the basis of analyte adduct formation and liquid chromatography–tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1072:100-104. [DOI: 10.1016/j.jchromb.2017.11.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2017] [Revised: 11/02/2017] [Accepted: 11/03/2017] [Indexed: 10/18/2022]
|
2
|
Van Hee P, Neels H, De Doncker M, Vrydags N, Schatteman K, Uyttenbroeck W, Hamers N, Himpe D, Lambert W. Analysis of γ-hydroxybutyric acid, DL-lactic acid, glycolic acid, ethylene glycol and other glycols in body fluids by a direct injection gas chromatography-mass spectrometry assay for wide use. ACTA ACUST UNITED AC 2004; 42:1341-5. [PMID: 15576294 DOI: 10.1515/cclm.2004.252] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
AbstractAnalysis of blood of severely intoxicated patients always requires prompt investigation. Diagnosis of intoxication with ethylene glycol, γ-hydroxybutyric acid or D-lactic acid takes hours, since several different procedures are required. Rapid derivatization of the common hydroxyl function may resolve this analytical problem.Here we describe a fast method for the simultaneous measurement of ethylene glycol, glycolic acid, γ-hydroxybutyric acid and racemic lactic acid. Only 20 µl of serum, plasma or urine are required for immediate derivatization at 70°C with 750 µl of bis-N,O-trimethylsilyl trifluoroacetamide after adding 20 µl of internal standard solution (1,3-propylene glycol) and 20 µl of the catalyst dimethylformamide. After centrifugation an aliquot is transferred to a gas chromatographic system and analyzed with electron-impact mass spectrometry in selective ion monitoring mode.The derivatized acids and ethylene glycol are well separated and detected with a limit of detection ranging from 0.12 mg/l for ethylene glycol to 0.95 mg/l for γ-hydroxybutyric acid, while the limit of quantification ranged from 0.4 mg/l for ethylene glycol to 3.15 mg/l for γ-hydroxybutyric acid. The method is linear from 0.5 to 1800 mg/l blood for ethylene glycol, from 0.7 to 1200 mg/l for lactic acid, from 1.2 to 1800 mg/l for glycolic acid, and from 3.2 to 200 mg/l for γ-hydroxybutyric acid, with analytical recoveries, accuracy, day-to-day and within-day precision well within the required limits. Total analysis time with one calibrator was 30 min, derivatization time included.This method is very suitable for emergency toxicology, since several toxic substances can be quantified simultaneously in a fast and sensitive manner.
Collapse
Affiliation(s)
- Paul Van Hee
- Laboratory of Biochemistry and Toxicology, Ziekenhuis Netwerk Antwerpen Stuivenberg, Antwerp, Belgium
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2003; 38:1117-1124. [PMID: 14595863 DOI: 10.1002/jms.413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
|