1
|
Hart A, Dudzic JP, Clarke JW, Eby J, Perlman SJ, Bazalova-Carter M. High-throughput, low-cost FLASH: irradiation of Drosophila melanogaster with low-energy X-rays using time structures spanning conventional and ultrahigh dose rates. JOURNAL OF RADIATION RESEARCH 2024; 65:836-844. [PMID: 39422537 PMCID: PMC11629999 DOI: 10.1093/jrr/rrae079] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2024] [Revised: 08/16/2024] [Indexed: 10/19/2024]
Abstract
FLASH radiotherapy is an emerging technique in radiation oncology that may improve clinical outcomes by reducing normal tissue toxicities. The physical radiation characteristics needed to induce the radiobiological benefits of FLASH are still an active area of investigation. To determine the dose rate, range of doses and delivery time structure necessary to trigger the FLASH effect, Drosophila melanogaster were exposed to ultrahigh dose rate (UHDR) or conventional radiotherapy dose rate (CONV) 120-kVp X-rays. A conventional X-ray tube outfitted with a shutter system was used to deliver 17- to 44-Gy doses to third-instar D. melanogaster larvae at both UHDR (210 Gy/s) and CONV (0.2-0.4 Gy/s) dose rates. The larvae were then tracked through development to adulthood and scored for eclosion and lifespan. Larvae exposed to UHDR eclosed at higher rates and had longer median survival as adults compared to those treated with CONV at the same doses. Eclosion rates at 24 Gy were 68% higher for the UHDR group (P < 0.05). Median survival from 22 Gy was >22 days for UHDR and 17 days for CONV (P < 0.01). Two normal tissue-sparing effects were observed for D. melanogaster irradiated with UHDR 120-kVp X-rays. The effects appeared only at intermediate doses and may be useful in establishing the dose range over which the benefits of FLASH can be obtained. This work also demonstrates the usefulness of a high-throughput fruit fly model and a low-cost X-ray tube system for radiobiological FLASH research.
Collapse
Affiliation(s)
- Alexander Hart
- Department of Physics and Astronomy, University of Victoria, 3800 Finnerty Road, Victoria, BC V8P 5C2, Canada
| | - Jan P Dudzic
- Department of Biology, University of Victoria, 3800 Finnerty Road, Victoria, BC V8P 5C2, Canada
| | - Jameson W Clarke
- Department of Biology, University of Victoria, 3800 Finnerty Road, Victoria, BC V8P 5C2, Canada
| | - Jonathan Eby
- Institute of Biomedical Engineering, University of Toronto, 164 College St. Toronto, Ontario M5S 3E2, Canada
| | - Steve J Perlman
- Department of Biology, University of Victoria, 3800 Finnerty Road, Victoria, BC V8P 5C2, Canada
| | - Magdalena Bazalova-Carter
- Department of Physics and Astronomy, University of Victoria, 3800 Finnerty Road, Victoria, BC V8P 5C2, Canada
| |
Collapse
|
2
|
Nakano H, Shiinoki T, Tanabe S, Utsunomiya S, Kaidu M, Nishio T, Ishikawa H. Assessing tumor volumetric reduction with consideration for setup errors based on mathematical tumor model and microdosimetric kinetic model in single-isocenter VMAT for brain metastases. Phys Eng Sci Med 2024; 47:1385-1396. [PMID: 38884671 DOI: 10.1007/s13246-024-01451-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/21/2024] [Indexed: 06/18/2024]
Abstract
The volumetric reduction rate (VRR) was evaluated with consideration for six degrees-of-freedom (6DoF) patient setup errors based on a mathematical tumor model in single-isocenter volumetric modulated arc therapy (SI-VMAT) for brain metastases. Simulated gross tumor volumes (GTV) of 1.0 cm and dose distribution were created (27 Gy/3 fractions). The distance between the GTV center and isocenter (d) was set at 0-10 cm. The GTV was translated within 0-1.0 mm (Trans) and rotated within 0-1.0° (Rot) in the three axis directions using affine transformation. The tumor growth volume was calculated using a multicomponent mathematical model (MCTM), and lethal effects of irradiation and repair from damage during irradiation were calculated by a microdosimetric kinetic model (MKM) for non-small cell lung cancer (NSCLC) A549 and NCI-H460 (H460) cells. The VRRs were calculated 5 days after the end of irradiation using the physical dose to the GTV for varying d and 6DoF setup errors. The tolerance value of VRR, the GTV volume reduction rate, was set at 5%, based on the pre-irradiation GTV volume. With the exception of the only one A549 condition where (Trans, Rot) = (1.0 mm, 1.0°) was repeated for 3 fractions, all conditions met all the tolerance VRR values for A549 and H460 cells with varying d from 0 to 10 cm. Evaluation based on the mathematical tumor model suggested that if the 6DoF setup errors at each irradiation could be kept within 1.0 mm and 1.0°, there would be little effect on tumor volume regardless of the distance from the isocenter in SI-VMAT.
Collapse
Affiliation(s)
- Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan.
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan.
| | - Takehiro Shiinoki
- Department of Radiation Oncology, Yamaguchi University, Minamikogushi 1-1-1 Ube, Yamaguchi, Japan
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Motoki Kaidu
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| |
Collapse
|
3
|
Özer Simsek Z, Aras S, Cikrikcioglu M, Baydili KN, Cortuk M. Melatonin as a radioprotective agent against flattening filter and flattening filter-free beam in radiotherapy-induced lung tissue damage. Int J Radiat Biol 2024; 101:28-34. [PMID: 39074356 DOI: 10.1080/09553002.2024.2381492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 03/09/2024] [Accepted: 07/11/2024] [Indexed: 07/31/2024]
Abstract
BACKGROUND Radiotherapy is a widely used treatment method in oncology, applied by delivering high-energy particles or waves to the tumor tissue. Although tumor cells are targeted with radiotherapy, it can cause acute or long-term damage to healthy tissues. Therefore, the preservation of healthy tissues has been an important subject of various scientific researches. Melatonin has been shown to have a radioprotective effect on many tissues and organs such as liver, parotid gland, brain, and testicles. This study aimed to evaluate the protective effect of melatonin against the radiation at various doses and rates administered to the lung tissue of healthy mice. METHODS This study was a randomized case-control study conducted with 80 rats comprising 10 groups with eight animals per group. Of the 10 groups, first is the control group, which is not given any melatonin, and second is the group that does not receive RT, which is given only melatonin, and the other eight groups are RT groups, four with melatonin and four without melatonin. RESULTS There was no statistical difference in terms of histopathological findings in the lung tissue between the second group, which did not receive radiotherapy and received only melatonin, and the control group. Lung damage due to radiotherapy was statistically significantly higher in the groups that did not receive melatonin compared to the groups that received melatonin. CONCLUSIONS This study revealed that melatonin has a protective effect against the cytotoxic damage of RT in rats receiving RT.
Collapse
Affiliation(s)
- Zuhal Özer Simsek
- Department of Chest Intensive Care Unit, Kayseri City Hospitals, Kayseri, Turkey
| | - Serhat Aras
- Department of Radiation Oncology, Haydarpasa Numune Training and Research Hospital, University of Health Sciences Turkey, Istanbul, Turkey
| | - Makbule Cikrikcioglu
- Department of Pathology, Haydarpasa Numune Training and Research Hospital, University of Health Sciences Turkey, Istanbul, Turkey
| | - Kursad Nuri Baydili
- Department of Biostatistics, University of Health Sciences Turkey, Istanbul, Turkey
| | - Mustafa Cortuk
- Department of Chest Diseases, Health Science University Yedikule Chest Diseases and Thoracic Surgery Hospital, İstanbul, Turkey
| |
Collapse
|
4
|
Manna S, Singh S, Gupta PK, T R. Dosimetric and Radiobiological Impact of Flattening Filter-Free Beam and Dose Calculation Algorithm Using RapidArc Plans for Cervical Cancer Treatment. PRECISION RADIATION ONCOLOGY 2023; 7:197-206. [PMID: 40337206 PMCID: PMC11935009 DOI: 10.1002/pro6.1207] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 04/28/2023] [Accepted: 05/15/2023] [Indexed: 05/09/2025] Open
Abstract
Purpose The aim of this study is to quantify the potential benefits of a flattening filter-free (FFF) beam and implement a dose-computation algorithm for cervical radiotherapy through dosimetric and radiobiological analyses using RapidArc. Methods Thirty-three patients were enrolled, and four RapidArc plans were created for each patient using a dual-arc flattening filter and 6-MV FFF photon beams for the two calculation algorithms. Homogeneity index (HI), conformity index (CI), target coverage, monitor units (MUs), and organ-at-risk (OAR) dosimetric characteristics were compared between the plans. Radiobiological characteristics and normal tissue complication probability (NTCP) scores were computed for the OAR using different biological models. Results No significant differences were observed in the Dmax, D98%, and CI in the planning target volume (PTV). Both computations estimated a significant difference in V95%, D2%, and HI for the PTV. Furthermore, the FFF beam showed a significant increase in the MUs and a significant reduction in V30% for the femoral heads. The NTCP score showed a significant increase in the late effects on the bladder, rectum, and bowel with FFF beams. Conclusion The current study recommends FFF beams for better conformity, comparable dose coverage for the target, and OAR sparing invariable to the dose computation algorithm. The difference in the NTCP score for OAR was minimal with the FFF beam.
Collapse
Affiliation(s)
- Sumanta Manna
- Medical PhysicsKalyan Singh Super Specialty Cancer InstituteLucknowUttar PradeshINDIA
| | - Sharad Singh
- Radiation OncologyKalyan Singh Super Specialty Cancer InstituteLucknowUttar PradeshINDIA
| | - Pramod Kumar Gupta
- Radiation OncologyKalyan Singh Super Specialty Cancer InstituteLucknowUttar PradeshINDIA
| | - Ragul T
- Medical PhysicsKalyan Singh Super Specialty Cancer InstituteLucknowUttar PradeshINDIA
| |
Collapse
|
5
|
Nakano H, Shiinoki T, Tanabe S, Utsunomiya S, Takizawa T, Kaidu M, Nishio T, Ishikawa H. Mathematical model combined with microdosimetric kinetic model for tumor volume calculation in stereotactic body radiation therapy. Sci Rep 2023; 13:10981. [PMID: 37414844 PMCID: PMC10326039 DOI: 10.1038/s41598-023-38232-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 07/05/2023] [Indexed: 07/08/2023] Open
Abstract
We proposed a new mathematical model that combines an ordinary differential equation (ODE) and microdosimetric kinetic model (MKM) to predict the tumor-cell lethal effect of Stereotactic body radiation therapy (SBRT) applied to non-small cell lung cancer (NSCLC). The tumor growth volume was calculated by the ODE in the multi-component mathematical model (MCM) for the cell lines NSCLC A549 and NCI-H460 (H460). The prescription doses 48 Gy/4 fr and 54 Gy/3 fr were used in the SBRT, and the effect of the SBRT on tumor cells was evaluated by the MKM. We also evaluated the effects of (1) linear quadratic model (LQM) and the MKM, (2) varying the ratio of active and quiescent tumors for the total tumor volume, and (3) the length of the dose-delivery time per fractionated dose (tinter) on the initial tumor volume. We used the ratio of the tumor volume at 1 day after the end of irradiation to the tumor volume before irradiation to define the radiation effectiveness value (REV). The combination of MKM and MCM significantly reduced REV at 48 Gy/4 fr compared to the combination of LQM and MCM. The ratio of active tumors and the prolonging of tinter affected the decrease in the REV for A549 and H460 cells. We evaluated the tumor volume considering a large fractionated dose and the dose-delivery time by combining the MKM with a mathematical model of tumor growth using an ODE in lung SBRT for NSCLC A549 and H460 cells.
Collapse
Affiliation(s)
- Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan.
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan.
| | - Takehiro Shiinoki
- Department of Radiation Oncology, Yamaguchi University, Minamikogushi 1-1-1 Ube, Yamaguchi, Japan
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-Dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Takeshi Takizawa
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, 3057 Yamada, Nishi-ku, Niigata-shi, Niigata, Japan
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Motoki Kaidu
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| | - Teiji Nishio
- Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, 1-7 Yamadaoka, Suita-shi, Osaka, Japan
| | - Hiroyuki Ishikawa
- Department of Radiology and Radiation Oncology, Niigata University Graduate School of Medical and Dental Sciences, 1-757 Asahimachi-dori, Chuo-ku, Niigata-shi, Niigata, Japan
| |
Collapse
|
6
|
Kouris P, Moutsatsos A, Pappas EP, Beli I, Pantelakos P, Karaiskos P, Pantelis E. Assessing the dose rate delivery of helical TomoTherapy prostate and head & neck treatments. Biomed Phys Eng Express 2021; 8. [PMID: 34755680 DOI: 10.1088/2057-1976/ac37cb] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 11/09/2021] [Indexed: 11/11/2022]
Abstract
The dose rate distributions delivered to 55 prostate and head & neck (H&N) cancer patients treated with a helical TomoTherapy (HT) system were resolved and assessed with regard to pitch and field width defined during treatment planning. Statistical analysis of the studied cases showed that the median treatment delivery time was 4.4 min and 6.3 min for the prostate and H&N cases, respectively. Dose rate volume histogram data for the studied cases showed that the 25% and 12% of the volume of the planning target volumes of the prostate and H&N cases are irradiated with a dose rate of greater or equal to 1 Gy min-1. Quartile dose rate (QDR) data confirmed that in HT, where the target is irradiated in slices, most of the dose is delivered to each voxel of the target when it travels within the beam. Analysis of the planning data from all cases showed that this lasts for 68 s (median value). QDRs results showed that using the 2.5 cm field width, 75% of the prescribed dose is delivered to target voxels with a median dose rate of at least 3.2 Gy min-1and 4.5 Gy min-1, for the prostate and H&N cases, respectively. Systematically higher dose rates were observed for the H&N cases due to the shallower depths of the lesions in this anatomical site. Delivered dose rates were also found to increase with field width and pitch setting, due to the higher output of the system which, in general, results in accordingly decreased total treatment time. The biological effect of the dose rate findings of this work needs to be further investigated using in-vitro studies and clinical treatment data.
Collapse
Affiliation(s)
- P Kouris
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece
| | - A Moutsatsos
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece.,Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - E P Pappas
- Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - I Beli
- Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - P Pantelakos
- Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| | - P Karaiskos
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece
| | - E Pantelis
- Medical Physics Laboratory, Medical School, National and Kapodistrian University of Athens, 75 Mikras Asias, 11527 Athens, Greece.,Radiotherapy and Radiosurgery Department, Latropolis Clinic, 54-56 Ethnikis Antistaseos, 15231 Athens, Greece
| |
Collapse
|
7
|
Dosimetric impact of FFF over FF beam using VMAT for brain neoplasms treated with radiotherapy. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2021. [DOI: 10.2478/pjmpe-2021-0023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Abstract
Background: This study was conducted to assess the dosimetric impact of FFF beam plans on high-grade brain neoplasms using the VMAT technique when compared with FF beam plans.
Material and Methods: Thirty patients with high-grade brain neoplasms, who had received radiotherapy using VMAT technique retrospectively were selected for this study. All the patients were planned for VMAT using 6MV_FF beam and the same plan was re-optimized using 6MV_FFF beam keeping the same dose constraint. Radiotherapy dose distribution on planning target volume (PTV) and organs at risk (OAR), target conformity index (CI), Homogeneity Index (HI), Low dose volume in the patient (V5, V10, V20, and V30), and Integral dose to the whole body in both plans were compared.
Results: The PTV coverage and OAR’s showed no significant differences in dose distribution between the FFF and FF beam VMAT planning. There was a reduction of the average maximum dose in the right eye, left eye, right optic nerve, and left optic nerve using FFF beams. The reduction in average low dose volume was observed in V5, V10, V20, V30, and Mean Dose. Also, a significant reduction was observed in the integral dose to the whole body using the FFF beam.
Conclusions: Using FFF beams with VMAT is doable for the treatment of high-grade brain neoplasms, and the delivery mode of the FFF beam in VMAT may yield similar results to FF beam which should be confirmed in a large scale prospective clinical trial.
Collapse
|
8
|
Nakano H, Kawahara D, Tanabe S, Utsunomiya S, Takizawa T, Sakai M, Nakano T, Ohta A, Kaidu M, Ishikawa H. Calculated relative biological effectiveness (RBE) for initial DNA double-strand breaks (DSB) from flattening filter and flattening filter-free 6 MV X-ray fields. BJR Open 2021; 3:20200072. [PMID: 34286177 PMCID: PMC8256801 DOI: 10.1259/bjro.20200072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2020] [Accepted: 02/25/2021] [Indexed: 12/14/2022] Open
Abstract
Objectives We evaluated the radiobiological effectiveness based on the yields of DNA double-strand breaks (DSBs) of field induction with flattening filter (FF) and FF-free (FFF) photon beams. Methods We used the particle and heavy ion transport system (PHITS) and a water equivalent phantom (30 × 30 × 30 cm3) to calculate the physical qualities of the dose-mean lineal energy (yD) with 6 MV FF and FFF. The relative biological effectiveness based on the yields of DNA-DSBs (RBEDSB) was calculated for standard radiation such as 220 kVp X-rays by using the estimating yields of SSBs and DSBs. The measurement points used to calculate the in-field yD and RBEDSB were located at a depth of 3, 5, and 10 cm in the water equivalent phantom on the central axis. Measurement points at 6, 8, and 10 cm in the lateral direction of each of the three depths from the central axis were set to calculate the out-of-field yD and RBEDSB. Results The RBEDSB of FFF in-field was 1.7% higher than FF at each measurement depth. The RBEDSB of FFF out-of-field was 1.9 to 6.4% higher than FF at each depth measurement point. As the distance to out-of-field increased, the RBEDSB of FFF rose higher than those of FF. FFF has a larger RBEDSB than FF based on the yields of DNA-DSBs as the distance to out-of-field increased. Conclusions The out-of-field radiobiological effect of FFF could thus be greater than that of FF since the spreading of the radiation dose out-of-field with FFF could be a concern compared to the FF. Advances in knowledge The RBEDSB of FFF of out-of-field might be larger than FF.
Collapse
Affiliation(s)
- Hisashi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Daisuke Kawahara
- Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University, 1-2-3 Kasumi, Minami-ku, Hiroshima-shi, Hiroshima, Japan
| | - Satoshi Tanabe
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Satoru Utsunomiya
- Department of Radiological Technology, Niigata University Graduate School of Health Sciences, 2-746 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | | | - Madoka Sakai
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Toshimichi Nakano
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Atsushi Ohta
- Department of Radiation Oncology, Niigata University Medical and Dental Hospital, 1-757 Asahimachi-dori, Chuo-ku, Niigata, Japan
| | - Motoki Kaidu
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, Niigata, 3057 Yamada, Nishi-ku, Niigata, Japan
| | - Hiroyuki Ishikawa
- Department of Radiation Oncology, Niigata Neurosurgical Hospital, Niigata, 3057 Yamada, Nishi-ku, Niigata, Japan
| |
Collapse
|
9
|
Effect of Flattening Filter and Flattening Filter Free beams on radiotherapy-induced peripheral blood cell damage. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109383] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
10
|
Aras S, Tanzer İO, Can Ü, Sümer E, Baydili KN. The role of melatonin on acute thyroid damage induced by high dose rate X-ray in head and neck radiotherapy. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2020.109206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
11
|
Cerviño LI, Soultan D, Advani SJ, Cornell M, Yock A, Pettersson N, Song WY, Aguilera J, Murphy J, Hoh C, James C, Paravati A, Coope R, Gill B, Moiseenko V. An in vitro study for the dosimetric and radiobiological validation of respiratory gating in conventional and hypofractionated radiotherapy of the lung: effect of dose, dose rate, and breathing pattern. Phys Med Biol 2019; 64:135009. [PMID: 31189137 DOI: 10.1088/1361-6560/ab2940] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Stereotactic body radiotherapy (SBRT) of the lung has become a standard of care for early-stage inoperable non-small cell lung cancer (NSCLC). A common strategy to manage respiratory motion is gating, which inevitably results in an increase in treatment time, especially in irregularly-breathing patients. Flattening-filter free (FFF) beams allow for delivery of the treatment at a higher dose rate, therefore counteracting the lengthened treatment time due to frequent interruption of the beam during gated radiotherapy. In this study, we perform our in vitro evaluation of the dosimetric and radiobiological effect of gated lung SBRT with simultaneous integrated boost (SIB) using both flattened and FFF beams. A moving thorax-shaped phantom with inserts and applicators was used for simulation, planning, gated treatment delivery measurements and in vitro tests. The effects of gating window, dose rate, and breathing pattern were evaluated. Planned doses represented a typical conventional fractionation, 200 cGy per fraction with SIB to 240 cGy, flattened beam only, and SBRT, 800 cGy with SIB to 900 cGy, flattened and FFF beams. Ideal, as well as regular and irregular patient-specific breathing patterns with and without gating were used. A survival assay for lung adenocarcinoma A549 cell line was performed. Delivered dose was within 6% for locations planned to receive 200 and 800 cGy and within 4% for SIB locations. Time between first beam-on and last beam-off varied from approximately 1.5 min for conventional fractionation, 200/240 cGy, to 10.5 min for gated SBRT, 800/900 cGy doses, flattened beam and irregular breathing motion pattern. With FFF beams dose delivery time was shorter by a factor of 2-3, depending on the gating window and breathing pattern. We have found that, for the most part, survival depended on dose and not on dose rate, gating window, or breathing regularity.
Collapse
Affiliation(s)
- Laura I Cerviño
- Department of Radiation Medicine and Applied Sciences, University of California San Diego, La Jolla, CA 92093, United States of America. Author to whom correspondence should be addressed
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|