1
|
Zhang Y, Jiang Z, Zhang Y, Ren L. A review on 4D cone-beam CT (4D-CBCT) in radiation therapy: Technical advances and clinical applications. Med Phys 2024; 51:5164-5180. [PMID: 38922912 PMCID: PMC11321939 DOI: 10.1002/mp.17269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 03/05/2024] [Accepted: 06/01/2024] [Indexed: 06/28/2024] Open
Abstract
Cone-beam CT (CBCT) is the most commonly used onboard imaging technique for target localization in radiation therapy. Conventional 3D CBCT acquires x-ray cone-beam projections at multiple angles around the patient to reconstruct 3D images of the patient in the treatment room. However, despite its wide usage, 3D CBCT is limited in imaging disease sites affected by respiratory motions or other dynamic changes within the body, as it lacks time-resolved information. To overcome this limitation, 4D-CBCT was developed to incorporate a time dimension in the imaging to account for the patient's motion during the acquisitions. For example, respiration-correlated 4D-CBCT divides the breathing cycles into different phase bins and reconstructs 3D images for each phase bin, ultimately generating a complete set of 4D images. 4D-CBCT is valuable for localizing tumors in the thoracic and abdominal regions where the localization accuracy is affected by respiratory motions. This is especially important for hypofractionated stereotactic body radiation therapy (SBRT), which delivers much higher fractional doses in fewer fractions than conventional fractionated treatments. Nonetheless, 4D-CBCT does face certain limitations, including long scanning times, high imaging doses, and compromised image quality due to the necessity of acquiring sufficient x-ray projections for each respiratory phase. In order to address these challenges, numerous methods have been developed to achieve fast, low-dose, and high-quality 4D-CBCT. This paper aims to review the technical developments surrounding 4D-CBCT comprehensively. It will explore conventional algorithms and recent deep learning-based approaches, delving into their capabilities and limitations. Additionally, the paper will discuss the potential clinical applications of 4D-CBCT and outline a future roadmap, highlighting areas for further research and development. Through this exploration, the readers will better understand 4D-CBCT's capabilities and potential to enhance radiation therapy.
Collapse
Affiliation(s)
- Yawei Zhang
- University of Florida Proton Therapy Institute, Jacksonville, FL 32206, USA
- Department of Radiation Oncology, University of Florida College of Medicine, Gainesville, FL 32608, USA
| | - Zhuoran Jiang
- Medical Physics Graduate Program, Duke University, Durham, NC 27710, USA
| | - You Zhang
- Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX 75390, USA
| | - Lei Ren
- Department of Radiation Oncology, University of Maryland, Baltimore, MD 21201, USA
| |
Collapse
|
2
|
Ukon K, Arai Y, Takao S, Matsuura T, Ishikawa M, Shirato H, Shimizu S, Umegaki K, Miyamoto N. Prediction of target position from multiple fiducial markers by partial least squares regression in real-time tumor-tracking radiation therapy. JOURNAL OF RADIATION RESEARCH 2021; 62:926-933. [PMID: 34196697 PMCID: PMC8438269 DOI: 10.1093/jrr/rrab054] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/19/2021] [Revised: 03/24/2021] [Indexed: 06/13/2023]
Abstract
The purpose of this work is to show the usefulness of a prediction method of tumor location based on partial least squares regression (PLSR) using multiple fiducial markers. The trajectory data of respiratory motion of four internal fiducial markers inserted in lungs were used for the analysis. The position of one of the four markers was assumed to be the tumor position and was predicted by other three fiducial markers. Regression coefficients for prediction of the position of the tumor-assumed marker from the fiducial markers' positions is derived by PLSR. The tracking error and the gating error were evaluated assuming two possible variations. First, the variation of the position definition of the tumor and the markers on treatment planning computed tomograhy (CT) images. Second, the intra-fractional anatomical variation which leads the distance change between the tumor and markers during the course of treatment. For comparison, rigid predictions and ordinally multiple linear regression (MLR) predictions were also evaluated. The tracking and gating errors of PLSR prediction were smaller than those of other prediction methods. Ninety-fifth percentile of tracking/gating error in all trials were 3.7/4.1 mm, respectively in PLSR prediction for superior-inferior direction. The results suggested that PLSR prediction was robust to variations, and clinically applicable accuracy could be achievable for targeting tumors.
Collapse
Affiliation(s)
- Kanako Ukon
- Graduate School of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan
| | - Yohei Arai
- Graduate School of Engineering, Hokkaido University, North 13, West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan
| | - Seishin Takao
- Department of Medical Physics, Hokkaido University Hospital, North 14, West 5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan
- Faculty of Engineering, Hokkaido University, North13, West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan
| | - Taeko Matsuura
- Department of Medical Physics, Hokkaido University Hospital, North 14, West 5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan
- Faculty of Engineering, Hokkaido University, North13, West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan
| | - Masayori Ishikawa
- Faculty of Health Sciences, Hokkaido University, North12, West 5, Kita-ku, Sapporo, Hokkaido 060-0812, Japan
| | - Hiroki Shirato
- Faculty of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan
| | - Shinichi Shimizu
- Department of Medical Physics, Hokkaido University Hospital, North 14, West 5, Kita-ku, Sapporo, Hokkaido 060-8648, Japan
- Faculty of Medicine, Hokkaido University, North 15, West 7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan
| | - Kikuo Umegaki
- Faculty of Engineering, Hokkaido University, North13, West 8, Kita-ku, Sapporo, Hokkaido 060-8628, Japan
| | - Naoki Miyamoto
- Corresponding author: Faculty of Engineering, Hokkaido University, North 13, West 8, Kita-ku, Sapporo, Hokkaido 060-8638, Japan. Tel: +81-11-706-6673, E-mail address:
| |
Collapse
|
3
|
Vergalasova I, Cai J. A modern review of the uncertainties in volumetric imaging of respiratory-induced target motion in lung radiotherapy. Med Phys 2020; 47:e988-e1008. [PMID: 32506452 DOI: 10.1002/mp.14312] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2019] [Revised: 05/15/2020] [Accepted: 05/26/2020] [Indexed: 12/25/2022] Open
Abstract
Radiotherapy has become a critical component for the treatment of all stages and types of lung cancer, often times being the primary gateway to a cure. However, given that radiation can cause harmful side effects depending on how much surrounding healthy tissue is exposed, treatment of the lung can be particularly challenging due to the presence of moving targets. Careful implementation of every step in the radiotherapy process is absolutely integral for attaining optimal clinical outcomes. With the advent and now widespread use of stereotactic body radiation therapy (SBRT), where extremely large doses are delivered, accurate, and precise dose targeting is especially vital to achieve an optimal risk to benefit ratio. This has largely become possible due to the rapid development of image-guided technology. Although imaging is critical to the success of radiotherapy, it can often be plagued with uncertainties due to respiratory-induced target motion. There has and continues to be an immense research effort aimed at acknowledging and addressing these uncertainties to further our abilities to more precisely target radiation treatment. Thus, the goal of this article is to provide a detailed review of the prevailing uncertainties that remain to be investigated across the different imaging modalities, as well as to highlight the more modern solutions to imaging motion and their role in addressing the current challenges.
Collapse
Affiliation(s)
- Irina Vergalasova
- Department of Radiation Oncology, Rutgers Cancer Institute of New Jersey, Rutgers University, New Brunswick, NJ, USA
| | - Jing Cai
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Kowloon, Hong Kong
| |
Collapse
|
4
|
Wang C, Hunt M, Zhang L, Rimner A, Yorke E, Lovelock M, Li X, Li T, Mageras G, Zhang P. Technical Note: 3D localization of lung tumors on cone beam CT projections via a convolutional recurrent neural network. Med Phys 2020; 47:1161-1166. [PMID: 31899807 DOI: 10.1002/mp.14007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2019] [Revised: 12/16/2019] [Accepted: 12/28/2019] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To design a convolutional recurrent neural network (CRNN) that calculates three-dimensional (3D) positions of lung tumors from continuously acquired cone beam computed tomography (CBCT) projections, and facilitates the sorting and reconstruction of 4D-CBCT images. METHOD Under an IRB-approved clinical lung protocol, kilovoltage (kV) projections of the setup CBCT were collected in free-breathing. Concurrently, an electromagnetic signal-guided system recorded motion traces of three transponders implanted in or near the tumor. Convolutional recurrent neural network was designed to utilize a convolutional neural network (CNN) for extracting relevant features of the kV projections around the tumor, followed by a recurrent neural network for analyzing the temporal patterns of the moving features. Convolutional recurrent neural network was trained on the simultaneously collected kV projections and motion traces, subsequently utilized to calculate motion traces solely based on the continuous feed of kV projections. To enhance performance, CRNN was also facilitated by frequent calibrations (e.g., at 10° gantry rotation intervals) derived from cross-correlation-based registrations between kV projections and templates created from the planning 4DCT. Convolutional recurrent neural network was validated on a leave-one-out strategy using data from 11 lung patients, including 5500 kV images. The root-mean-square error between the CRNN and motion traces was calculated to evaluate the localization accuracy. RESULT Three-dimensional displacement around the simulation position shown in the Calypso traces was 3.4 ± 1.7 mm. Using motion traces as ground truth, the 3D localization error of CRNN with calibrations was 1.3 ± 1.4 mm. CRNN had a success rate of 86 ± 8% in determining whether the motion was within a 3D displacement window of 2 mm. The latency was 20 ms when CRNN ran on a high-performance computer cluster. CONCLUSIONS CRNN is able to provide accurate localization of lung tumors with aid from frequent recalibrations using the conventional cross-correlation-based registration approach, and has the potential to remove reliance on the implanted fiducials.
Collapse
Affiliation(s)
- Chuang Wang
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Margie Hunt
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Lei Zhang
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Andreas Rimner
- Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Ellen Yorke
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Michael Lovelock
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Xiang Li
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Tianfang Li
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Gig Mageras
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| | - Pengpeng Zhang
- Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, 10065, USA
| |
Collapse
|
5
|
Haga A. [Visualization of Organ Motion Using Four Dimensional Cone-beam CT and Its Applications]. Nihon Hoshasen Gijutsu Gakkai Zasshi 2018; 74:1337-1342. [PMID: 30464102 DOI: 10.6009/jjrt.2018_jsrt_74.11.1337] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Affiliation(s)
- Akihiro Haga
- Department of Medical Image Informatics, Tokushima University
| |
Collapse
|