1
|
Tamura R, Doi T, Hirashio S, Sasaki K, Masuda Y, Shimizu A, Masaki T. A case report of atypical anti-glomerular basement membrane disease. BMC Nephrol 2022; 23:373. [PMID: 36402968 PMCID: PMC9675149 DOI: 10.1186/s12882-022-03007-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/24/2022] [Accepted: 11/14/2022] [Indexed: 11/20/2022] Open
Abstract
Background Anti-glomerular basement membrane (anti-GBM) disease is characterized by crescentic necrotizing glomerulonephritis, with linear deposits of immunoglobulin G (IgG) in the GBM. Classic anti-GBM disease is clinically associated with rapidly progressive glomerulonephritis with or without pulmonary hemorrhage. Some patients have a better renal prognosis and milder symptoms than those with classic anti-GBM disease, which is termed atypical anti-GBM disease. Case presentation A 43-year-old Japanese woman was admitted to our hospital complaining of hematuria that had persisted for more than one month. Serological examination revealed negativity for anti-nuclear, anti-neutrophilic cytoplasmic, and anti-GBM antibodies. However, renal biopsy showed cellular crescents. Immunofluorescence revealed strong diffuse linear capillary loop staining for IgG. An indirect immunofluorescence antibody method was performed by applying the patient serum to normal kidney tissue to confirm the presence of autoantibodies binding to the GBM. Using this method, anti-GBM antibodies were detected. The patient was treated with high-dose steroids, cyclophosphamide, and plasma exchange. Aggressive treatment resolved proteinuria and hematuria and improved renal function. Conclusions Renal biopsy is crucial in the diagnosis of anti-GBM disease, especially when serological tests are negative. Accurately identifying the presence of anti-GBM disease is important to initiate optimal treatment.
Collapse
|
2
|
Shiroshita A, Oda Y, Takenouchi S, Hagino N, Kataoka Y. Accuracy of Anti-GBM Antibodies in Diagnosing Anti-Glomerular Basement Membrane Disease: A Systematic Review and Meta-Analysis. Am J Nephrol 2021; 52:531-538. [PMID: 34515033 DOI: 10.1159/000518362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 07/06/2021] [Indexed: 02/01/2023]
Abstract
BACKGROUND The sensitivity and specificity of anti-glomerular basement membrane (GBM) antibodies have not been systematically analyzed. In this systematic review, we aimed to evaluate the diagnostic accuracy of anti-GBM antibodies for anti-GBM disease. SUMMARY Potential studies were searched using MEDLINE, Embase, the Cochrane Library, and the International Clinical Trials Registry Platform based on the index test and target condition. The inclusion criteria were prospective or retrospective cohort studies or case-control studies assessing the sensitivity and specificity of anti-GBM antibodies, and the reference standard was clinical diagnosis including biopsy results. The exclusion criteria were review articles, case reports, animal studies, and in vitro studies. Quality assessment was conducted based on the Quality Assessment of Diagnostic Accuracy Studies-2. The pooled estimates of sensitivity and specificity were calculated using a bivariate random-effects model. The overall quality was evaluated using the Grades of Recommendation, Assessment, Development, and Evaluation. Six studies (1,691 patients) and 11 index tests were included in our systematic review. A high risk of bias and concerns regarding the applicability of patient selection were noted because of the case-control design in 67% of the included studies. The pooled sensitivity and specificity were 93% (95% CI: 84-97%) and 97% (95% CI: 94-99%), respectively. The certainty of evidence was low because of the high risk of bias and indirectness. Key Messages: Anti-GBM antibodies may exhibit high sensitivity and specificity in the diagnosis of anti-GBM disease. Further cohort studies are needed to confirm their precise diagnostic accuracy and compare diagnostic accuracies among different immunoassays.
Collapse
Affiliation(s)
- Akihiro Shiroshita
- Department of Respiratory Medicine, Ichinomiyanishi Hospital, Ichinomiya, Japan
- Systematic Review Workshop Peer Support Group (SRWS-PSG), Osaka, Japan
| | - Yasuhiro Oda
- Division of Nephrology and Endocrinology, the University of Tokyo Graduate School of Medicine, Tokyo, Japan
| | - Seiji Takenouchi
- Department of Rheumatology, Ichinomiyanishi Hospital, Ichinomiya, Japan
| | - Noboru Hagino
- Department of Rheumatology, Teikyo University Chiba Medical Center, Chiba, Japan
| | - Yuki Kataoka
- Systematic Review Workshop Peer Support Group (SRWS-PSG), Osaka, Japan
- Department of Respiratory Medicine, Hyogo Prefectural Amagasaki General Medical Center, Amagasaki, Japan
- Department of Hospital Care Research Unit, Hyogo Prefectural Amagasaki General Medical Center, Amagasaki, Japan
| |
Collapse
|
3
|
Marino C, Grimaldi M, Sabatini P, Amato P, Pallavicino A, Ricciardelli C, D’Ursi AM. Fibromyalgia and Depression in Women: An 1H-NMR Metabolomic Study. Metabolites 2021; 11:429. [PMID: 34209136 PMCID: PMC8304744 DOI: 10.3390/metabo11070429] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2021] [Revised: 06/15/2021] [Accepted: 06/23/2021] [Indexed: 12/18/2022] Open
Abstract
Fibromyalgia is a chronic and systemic syndrome characterized by muscle, bone, and joint pain. It is a gender-specific condition with a 9:1 incidence ratio between women and men. Fibromyalgia is frequently associated with psychic disorders affecting the cognitive and emotional spheres. In the reported work, we compared 31 female fibromyalgia patients to 31 female healthy controls. They were analyzed for biochemical clinical parameters, for autoimmune markers, and were subjected to 1H-NMR metabolomics analysis. To identify a correlation between the metabolomic profile and the psychic condition, a subset of 19 fibromyalgia patients was subjected to HAM-A and HAM-D Hamilton depression tests. Multivariate statistical analysis showed the dysmetabolism of several metabolites involved in energy balance that are associated with systemic inflammatory conditions. The severity of depression worsens dysmetabolic conditions; conversely, glycine and glutamate, known for their critical role as neuromodulators, appear to be potential biomarkers of fibromyalgia and are associated with different severity depression conditions.
Collapse
Affiliation(s)
- Carmen Marino
- Department of Pharmacy, University of Salerno, Via Giovanni Paolo II, 84084 Fisciano, Italy; (C.M.); (M.G.); (A.P.); (C.R.)
| | - Manuela Grimaldi
- Department of Pharmacy, University of Salerno, Via Giovanni Paolo II, 84084 Fisciano, Italy; (C.M.); (M.G.); (A.P.); (C.R.)
| | - Paola Sabatini
- U.O.C. Clinical Pathology D.E.A. III Umberto I, Viale S. Francesco D’Assisi, 84014 Nocera Inferiore, Italy;
| | - Patrizia Amato
- ASL Ser. T Cava de’ Tirreni, Piazza Matteo Galdi 1/3, 84013 Pregiato, Italy;
| | - Arianna Pallavicino
- Department of Pharmacy, University of Salerno, Via Giovanni Paolo II, 84084 Fisciano, Italy; (C.M.); (M.G.); (A.P.); (C.R.)
| | - Carmen Ricciardelli
- Department of Pharmacy, University of Salerno, Via Giovanni Paolo II, 84084 Fisciano, Italy; (C.M.); (M.G.); (A.P.); (C.R.)
| | - Anna Maria D’Ursi
- Department of Pharmacy, University of Salerno, Via Giovanni Paolo II, 84084 Fisciano, Italy; (C.M.); (M.G.); (A.P.); (C.R.)
| |
Collapse
|
4
|
Busch MH, Aendekerk JP, van Beers JJBC, van Paassen P, Damoiseaux JGMC. Evaluation of the diagnostic performance of an immunoblot for ANCA and anti-GBM antibody detection. Autoimmunity 2020; 54:45-50. [PMID: 33215537 DOI: 10.1080/08916934.2020.1846185] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
The use of high-quality antigen-specific immunoassays for detecting anti-neutrophil cytoplasmic antibodies (ANCA) and anti-glomerular basement membrane (GBM) autoantibodies is recommended in patients with suspected ANCA vasculitis and/or anti-GBM disease. We analysed the diagnostic performance of a semi-quantitative and rapid immunoblot (EUROIMMUN AG, Lübeck, Germany) in two settings. Patient sera from different cohorts (ANCA vasculitis n = 187, anti-GBM disease n = 19, and disease controls n = 51) were used. The diagnostic performance of the immunoblot was assessed when used as a confirmatory test for the presence of ANCA in suspected ANCA vasculitis and when evaluating the presence of ANCA and/or anti-GBM antibodies in AAV and/or anti-GBM disease patients with a rapidly progressive glomerulonephritis (RPGN). In a confirmatory test setting, the immunoblot had an optimal sensitivity and specificity of 97.4 and 98.1% for PR3-ANCA and 98.5 and 96.4% for MPO-ANCA, respectively. With increasing test result ranges, a higher interval likelihood ratio (LR) was found for both ANCA entities. When evaluating for ANCA in patients with RPGN, the highest diagnostic accuracy (sensitivity 92.9% and specificity 100%) was obtained by using different cut-off values of positivity for PR3- (>5) and MPO-ANCA (>10). Also, the diagnostic performance for detecting anti-GBM was good (sensitivity 100% and specificity 100%). There are advantages over other assays in terms of time, costs, and interpretation of results. The immunoblot is a useful addition to current guidelines, particularly when a rapid diagnosis is necessary.
Collapse
Affiliation(s)
- Matthias H Busch
- Department of Nephrology and Clinical Immunology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Joop P Aendekerk
- Department of Nephrology and Clinical Immunology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Joyce J B C van Beers
- Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Pieter van Paassen
- Department of Nephrology and Clinical Immunology, Maastricht University Medical Center, Maastricht, The Netherlands
| | - Jan G M C Damoiseaux
- Central Diagnostic Laboratory, Maastricht University Medical Center, Maastricht, The Netherlands
| |
Collapse
|
5
|
Tan Y, Pang W, Jia X, Zhao MH. Comparison of the performance of a chemiluminescence assay and an ELISA for detection of anti-GBM antibodies. Ren Fail 2020; 42:48-53. [PMID: 31885301 PMCID: PMC6968565 DOI: 10.1080/0886022x.2019.1702056] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Objective Autoantibodies to the α3 chain noncollagen 1 domain of type IV collagen (α3(IV)NC1) are a serological hallmark in the diagnosis of anti-glomerular basement membrane (GBM) disease. The objective of our study was to compare the performance of anti-glomerular basement membrane (GBM) antibody detection by chemiluminescence immunoassay (CIA) and by enzyme-linked immunosorbent assays (ELISAs). Methods Sera from outpatients who were suspected to have anti-GBM disease and 31 patients with biopsy-proven anti-GBM disease were collected. Thirty normal controls were also included. All samples were tested for anti-GBM antibodies by CIA and commercial ELISA. The anti-GBM antibody-positive samples were confirmed by a homemade ELISA coated with recombinant human α3(IV)NC1. Results Compared with detection of anti-GBM antibodies with ELISA, detection of anti-GBM antibodies with CIA showed a positivity agreement of 70% and a negativity agreement of 98.6%. Among the 4 patients with different results, the anti-GBM antibody detection by CIA was in agreement with the homemade ELISA coated with recombinant human α3(IV)NC1 and the clinical diagnosis. In 31 patients with anti-GBM disease, good agreement was achieved in the detection of anti-GBM antibodies with CIA, commercial ELISA and the homemade ELISA (100%, 100%). The AUC for CIA and commercial ELISA was 0.987 and 0.966, respectively. Conclusions The detection of anti-GBM antibodies with CIA demonstrated good sensitivity and specificity and was in good agreement with our homemade ELISA, which seems better than the commercial ELISA in suspected anti-GBM disease patients. The three assays performed in parallel in the diagnosis of anti-GBM disease patients.
Collapse
Affiliation(s)
- Ying Tan
- Renal Division, Department of Medicine, Peking University First Hospital, Beijing, PR. China.,Institute of Nephrology, Peking University, Beijing, PR. China.,Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, PR China.,Key Laboratory of Chronic Kidney Disease Prevention and Treatment, Ministry of Education, Beijing, China
| | - Wei Pang
- Renal Division, Department of Medicine, Peking University First Hospital, Beijing, PR. China.,Institute of Nephrology, Peking University, Beijing, PR. China.,Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, PR China.,Key Laboratory of Chronic Kidney Disease Prevention and Treatment, Ministry of Education, Beijing, China
| | - Xiaoyu Jia
- Renal Division, Department of Medicine, Peking University First Hospital, Beijing, PR. China.,Institute of Nephrology, Peking University, Beijing, PR. China.,Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, PR China.,Key Laboratory of Chronic Kidney Disease Prevention and Treatment, Ministry of Education, Beijing, China
| | - Ming-Hui Zhao
- Renal Division, Department of Medicine, Peking University First Hospital, Beijing, PR. China.,Institute of Nephrology, Peking University, Beijing, PR. China.,Key Laboratory of Renal Disease, Ministry of Health of China, Beijing, PR China.,Key Laboratory of Chronic Kidney Disease Prevention and Treatment, Ministry of Education, Beijing, China.,Peking-Tsinghua Center for Life Sciences, Beijing, PR China
| |
Collapse
|
6
|
Albesa R, Sachs U, Infantino M, Manfredi M, Benucci M, Baus Y, Lutterbeck S, Andrade L, Morris K, Friedenberg A, Casas S, Bossuyt X, Mahler M. Increased prevalence of anti-DFS70 antibodies in young females: experience from a large international multi-center study on blood donors. Clin Chem Lab Med 2019; 57:999-1005. [PMID: 30739097 DOI: 10.1515/cclm-2018-1233] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2018] [Accepted: 12/27/2018] [Indexed: 08/02/2024]
Abstract
Background Isolated antibodies to DFS70 have been described in healthy individuals and are rarely found in patients with antinuclear antibody-associated autoimmune rheumatic diseases (AARD). However, no data is available on geographic differences in the prevalence of anti-DFS70 antibodies. We aimed to study the prevalence of anti-DFS70 antibodies in blood donor samples from several countries representing various ethnical backgrounds and geographic regions in the world. Methods Sera from apparently healthy blood donors (n≥300 per site) were collected in seven countries (USA, Italy, Spain, Germany, UK, Belgium and Brazil). All samples (n=2628) were tested for anti-DFS70 antibodies by QUANTA Flash DFS70 (Inova Diagnostics, Inc., San Diego, CA, USA). Results The prevalence of anti-DFS70 antibodies varied from 4/321 (1.2%, Italy) to 42/497 (8.5%, USA). Consequently, the prevalence of the antibodies was significantly higher in USA compared to all other countries (p<0.05). In addition, the prevalence in the combined cohort (all sites) was higher in young blood donors (<35 years; 5.0% vs. 2.7%; p=0.0017) and among females (4.5% vs. 3.0%; p=0.0446). However, when cohorts from different countries were corrected for age and gender, no significant difference between the countries were found. Conclusions This is the first study to analyze the prevalence of anti-DFS70 antibodies in different geographic areas using a standardized assay. Our findings show that the antibodies are most prevalent in young females.
Collapse
Affiliation(s)
| | - Ulrich Sachs
- Institute for Clinical Immunology and Transfusion Medicine, Justus Liebig University, Giessen, Germany
| | - Maria Infantino
- Immunology and Allergology Laboratory Unit, S. Giovanni di Dio Hospital, Laboratory Medicine, Florence, Italy
| | - Mariangela Manfredi
- Immunology and Allergology Laboratory Unit, S. Giovanni di Dio Hospital, Laboratory Medicine, Florence, Italy
| | - Maurizio Benucci
- Rheumatology Unit, S. Giovanni di Dio Hospital, Medicine Department, Florence, Italy
| | | | | | - Luis Andrade
- Rheumatology Division, Universidade Federal de Sao Paulo, São Paulo, Brazil
| | - Kieran Morris
- Northern Ireland Blood Transfusion Service, BCH Complex, Belfast, UK
| | | | | | - Xavier Bossuyt
- KU Leuven Department of Microbiology and Immunology, Leuven, Belgium
- University Hospitals Leuven, Department of Laboratory Medicine, Leuven, Belgium
| | - Michael Mahler
- Inova Diagnostics, INC, 9900 Old Grove Road, San Diego, CA 32131-1638, USA, Phone/Fax: +858 586 9900/858 586 9911
| |
Collapse
|
7
|
Adapa S, Konala VM, Hou J, Naramala S, Agrawal N, Dhingra H, Aronow WS. Seronegative atypical anti-glomerular basement membrane crescentic glomerulonephritis. ANNALS OF TRANSLATIONAL MEDICINE 2019; 7:246. [PMID: 31317016 DOI: 10.21037/atm.2019.04.60] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A 46-year-old female presented with a chief complaint of fatigue and intermittent painless gross hematuria for one month. The patient was fluid overloaded on physical examination and noted to be in acute renal failure with a serum creatinine of 10.8 mg/dL. The patient was emergently started on hemodialysis. Serologies were negative for antinuclear antibody (ANA), anti-neutrophilic cytoplasmic antibody (ANCA), and anti-glomerular basement membrane (anti-GBM) antibody. However, renal biopsy revealed 90% glomerular involvement by temporally heterogeneous crescents ranging from cellular to fibrous. Immunofluorescence studies revealed strong, linear glomerular capillary wall staining for immunoglobulin G (IgG). Although the patient was treated with pulse dose steroids and cyclophosphamide, the patient ultimately developed infectious complications from immunosuppression, and treatment was terminated. This case highlights the atypical presentation of anti-GBM disease diagnosed based on renal biopsy with negative serologies. Although rare, the possibility of atypical anti-GBM antibodies which are not detected by standard commercial assays should be considered in such cases.
Collapse
Affiliation(s)
- Sreedhar Adapa
- Division of Nephrology, The Nephrology Group, Fresno, CA, USA
| | - Venu Madhav Konala
- Department of Internal Medicine/Division of Medical Oncology, Ashland Bellefonte Cancer Center, Ashland, KY, USA
| | - Jean Hou
- Department of Pathology, Cedars-Sinai Medical Center, Los Angeles, CA, USA
| | - Srikanth Naramala
- Division of Rheumatology, Adventist Medical Center, Hanford, CA, USA
| | - Nikhil Agrawal
- Division of Nephrology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA, USA
| | - Hemant Dhingra
- Department of Medicine, St Agnes Medical Center, Fresno, CA, USA
| | - Wilbert S Aronow
- Division of Cardiology, Westchester Medical Center and New York Medical College, Valhalla, NY, USA
| |
Collapse
|
8
|
Mahroum N, Perez D, Shovman O, Watad A, Gilburd B, Amital H, Levy I, Shoenfeld Y. Anti-DFS70 among HIV-positive individuals - A prospective study. Best Pract Res Clin Rheumatol 2019; 32:605-609. [PMID: 31174828 DOI: 10.1016/j.berh.2019.01.009] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Anti-DFS70 is an anti-nuclear antibody directed against the DFS70 protein, which is produced in response to several stressful events. Since its discovery, this autoantigen-antibody complex has drawn the attention of many researchers, yet many questions remain unanswered. The DFS70 protein is crucial for HIV integration into the host DNA; however, the relationship between anti-DFS70 and HIV is unknown. A protective role of anti-DFS70 against HIV is possible due to the competition between the HIV integrase and the anti-DFS70 antibody on the same target site on DFS70. The current study aimed to assess the prevalence of anti-DFS70 in HIV-positive individuals seeking for possible interrelation. A total of 100 HIV-positive individuals followed up at the HIV unit at Sheba Medical Center were tested for the detection of anti-DFS70. A total of 92 non-HIV subjects, randomly selected, were tested and compared as controls. Chemiluminescence assay by QUANTA Flash was performed to evaluate the presence of anti-DFS70 antibodies. None of the HIV-positive individuals had a positive test result for anti-DFS70 (0%) compared to 10 out of 92 non-HIV individuals (10.9%). This is the first study addressing the prevalence of anti-DFS70 in HIV-positive patients. The rate of anti-DFS70 positivity was found to be significantly lower in HIV-positive individuals than in non-HIV individuals (p = 0.002). The absence of anti-DFS70 in HIV-positive subjects might imply that individuals who lack these antibodies are more susceptible to HIV infection. Further studies with large populations are needed to confirm this hypothesis.
Collapse
Affiliation(s)
- Naim Mahroum
- Department of Medicine 'B', Sheba Medical Center, Tel-Hashomer, Israel; HIV Unit, Sheba Medical Center, Tel-Hashomer, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
| | - Dolores Perez
- Zabludowicz Center for Autoimmune Diseases, Sheba Medical Center, Tel- Hashome, Israel.
| | - Ora Shovman
- Department of Medicine 'B', Sheba Medical Center, Tel-Hashomer, Israel; Zabludowicz Center for Autoimmune Diseases, Sheba Medical Center, Tel- Hashome, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
| | - Abdulla Watad
- Department of Medicine 'B', Sheba Medical Center, Tel-Hashomer, Israel; Zabludowicz Center for Autoimmune Diseases, Sheba Medical Center, Tel- Hashome, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
| | - Boris Gilburd
- Zabludowicz Center for Autoimmune Diseases, Sheba Medical Center, Tel- Hashome, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
| | - Howard Amital
- Department of Medicine 'B', Sheba Medical Center, Tel-Hashomer, Israel; Zabludowicz Center for Autoimmune Diseases, Sheba Medical Center, Tel- Hashome, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
| | - Itzchak Levy
- HIV Unit, Sheba Medical Center, Tel-Hashomer, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
| | - Yehuda Shoenfeld
- Zabludowicz Center for Autoimmune Diseases, Sheba Medical Center, Tel- Hashome, Israel; Sackler Faculty of Medicine, Tel-Aviv University, Tel-Aviv, Israel.
| |
Collapse
|
9
|
Abstract
Autoimmune diseases are very diverse and include many common diseases of unknown etiology.Diagnosis can be challenging but can be facilitated by the identification of characteristic autoantibodies (AuAbs), which are present in varying frequencies. Identification of such AuAbs requires a range of different techniques, depending on the autoantigens in question. Each individual AuAb assay is characterized by analytical sensitivity and specificity, which in turn determines clinical sensitivity and specificity in relation to diseases. Clinical sensitivities and specificities vary much, but many AuAb analyses can be of significant help in establishing correct diagnoses. It remains unsettled whether AuAbs are generally pathogenic, but it is generally agreed that autoimmune diseases are caused by a combination of genetic and environmental factors, and that early and correct diagnosis facilitates treatment.
Collapse
|
10
|
Clavarino G, Gauthier A, Hellmark T, Carron PL, Giovannini D, Colliard S, Dragon-Durey MA, Segelmark M, Cesbron JY, Dumestre-Pérard C. Routinely used immunoassays do not detect circulating anti-GBM antibodies against native NC1 hexamer and EA epitope of the α3 chain of type IV collagen. Eur J Immunol 2018; 48:1082-1084. [PMID: 29644627 DOI: 10.1002/eji.201747324] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2017] [Revised: 01/29/2018] [Accepted: 03/06/2018] [Indexed: 11/09/2022]
Abstract
Detection of circulating anti-GBM antibodies has a key role for the diagnosis of Goodpasture syndrome but immunoassays using purified or recombinant alpha3(IV)NC1 as antigen do not recognize all anti-GBM antibodies. We show that anti-GBM antibodies directed against epitopes in their native conformation or cryptic epitopes are detected by indirect immunofluorescence.
Collapse
Affiliation(s)
- Giovanna Clavarino
- Laboratoire d'Immunologie, Pôle de Biologie, Centre Hospitalier Universitaire Grenoble Alpes, Grenoble, Cedex 9, France.,BNI team, TIMC-IMAG UMR5525 Université Grenoble Alpes - CNRS, Grenoble, Cedex 9, France
| | - Arnaud Gauthier
- Laboratoire d'Immunologie, Pôle de Biologie, Centre Hospitalier Universitaire Grenoble Alpes, Grenoble, Cedex 9, France
| | | | - Pierre-Louis Carron
- Service de Néphrologie, Pôle Digestif Dune, Centre Hospitalier Universitaire Grenoble Alpes, Grenoble, Cedex 9, France
| | - Diane Giovannini
- Département d'Anatomie et de Cytologie Pathologiques, Pôle de Biologie, Centre Hospitalier Universitaire Grenoble Alpes, Grenoble, Cedex 9, France
| | - Sophie Colliard
- Laboratoire d'Immunologie, Pôle de Biologie, Centre Hospitalier Universitaire Grenoble Alpes, Grenoble, Cedex 9, France
| | | | - Mårten Segelmark
- Division of Drug Research, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Jean-Yves Cesbron
- Laboratoire d'Immunologie, Pôle de Biologie, Centre Hospitalier Universitaire Grenoble Alpes, Grenoble, Cedex 9, France.,BNI team, TIMC-IMAG UMR5525 Université Grenoble Alpes - CNRS, Grenoble, Cedex 9, France
| | - Chantal Dumestre-Pérard
- Laboratoire d'Immunologie, Pôle de Biologie, Centre Hospitalier Universitaire Grenoble Alpes, Grenoble, Cedex 9, France.,BNI team, TIMC-IMAG UMR5525 Université Grenoble Alpes - CNRS, Grenoble, Cedex 9, France
| |
Collapse
|
11
|
Bentow C, Rosenblum R, Correia P, Karayev E, Karayev D, Williams D, Kulczycka J, Fritzler MJ, Mahler M. Development and multi-center evaluation of a novel immunoadsorption method for anti-DFS70 antibodies. Lupus 2017; 25:897-904. [PMID: 27252267 DOI: 10.1177/0961203316641773] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
OBJECTIVE Antinuclear antibodies (ANA) represent a hallmark in the diagnosis of ANA-associated rheumatic diseases (AARD). However, anti-DFS70 antibodies are present in a higher portion of the healthy individuals (HI) than in patients with AARD. Consequently, we developed a novel, highly specific indirect immunofluorescence (IIF) method that blocks anti-DFS70 antibodies from binding to HEp-2 cells and to evaluate the method in a multi-center study. METHODS A total of 18 samples from systemic lupus erythematosus patients (SLE, n = 7) and HI (n = 11) were used for the initial development of the immunoadsorption method. For the multi-center evaluation, samples with a dense fine speckled (DFS) pattern (n = 99) were collected at three different sites based on their established IIF screening procedure at the respective laboratories. Additionally, four characterized samples with established clinically relevant IIF patterns (centromere, nucleolar, speckled, homogeneous) were blended in five different ratios (10%, 25%, 50%, 75%, 90%) with a sample positive for anti-DFS70 antibodies, which by itself showed a dense fine speckled (DFS) IIF pattern. All samples were tested by IIF with NOVA Lite HEp-2 ANA and NOVA Lite HEp-2 Select on the NOVA View® instrument, and also tested by QUANTA Flash DFS70 chemiluminescent immunoassay (CIA) for confirmation of anti-DFS70 antibodies (Inova Diagnostics, San Diego, CA, USA). RESULTS For the development of the immunoadsorption method, only 1/7 ANA-positive samples from SLE patients, but 8/10 ANA-positive samples from healthy individuals turned negative using the immunoadsorption. Subsequently, 73/99 (73.7%) of the DFS pattern samples were positive by CIA for anti-DFS70 antibodies showing a strong quantitative Spearman's correlation (rho = 0.57 (95% CI, 0.39-0.71, p < 0.0001)) between light intensity units (LIU) measured by NOVA View and CIA. Intensities measured with NOVA Lite HEp-2 and NOVA Lite HEp-2 Select demonstrated significantly lower intensity values after inhibition with DFS70 antigen (p < 0.0001). When samples were processed to mimic samples with mixed patterns (DFS + clinically relevant pattern), the new immunoadsorption method demonstrated that all clinically relevant patterns remained unchanged whereas the LIUs from NOVA View analysis significantly decreased after inhibition (p < 0.0001). CONCLUSION The data showed that the NOVA Lite HEp-2 Select kit effectively inhibits anti-DFS70 antibody binding to its cellular target antigen.
Collapse
Affiliation(s)
- C Bentow
- Department of Research, Inova Diagnostics, Inc., San Diego, USA
| | - R Rosenblum
- Department of Research, Inova Diagnostics, Inc., San Diego, USA
| | - P Correia
- RDL Reference Laboratory, Los Angeles, USA
| | - E Karayev
- RDL Reference Laboratory, Los Angeles, USA
| | - D Karayev
- RDL Reference Laboratory, Los Angeles, USA
| | - D Williams
- Immunology Department, Southampton General Hospital, Southampton, UK
| | - J Kulczycka
- Department of Clinical Immunology and Transplantation, Center of Laboratory Medicine, Medical University of Gdansk, Gdansk, Poland
| | - M J Fritzler
- Cumming School of Medicine, University of Calgary, Calgary, Canada
| | - M Mahler
- Department of Research, Inova Diagnostics, Inc., San Diego, USA
| |
Collapse
|
12
|
Glassock RJ. Atypical anti-glomerular basement membrane disease: lessons learned. Clin Kidney J 2016; 9:653-6. [PMID: 27679709 PMCID: PMC5036901 DOI: 10.1093/ckj/sfw068] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2016] [Accepted: 06/29/2016] [Indexed: 11/12/2022] Open
Abstract
Anti-glomerular basement membrane (GBM) disease usually pursues a self-limited course, at least from the immunological perspective. In addition, circulating antibodies to cryptic, conformational epitopes within the NC1 domain of the alpha 3 chain of Type IV Collagen are commonly found at the zenith of the clinical disease. However, exceptions to these general rules do occur, as exemplified by two remarkable cases reported in this issue of the Clinical Kidney Journal. The possible explanations for and the lessons learned from these uncommon occurrences are discussed in this short commentary.
Collapse
Affiliation(s)
- Richard J Glassock
- David Geffen School of Medicine at UCLA , Laguna Niguel, Los Angeles, CA , USA
| |
Collapse
|
13
|
Bentow C, Fritzler MJ, Mummert E, Mahler M. Recognition of the dense fine speckled (DFS) pattern remains challenging: results from an international internet-based survey. AUTOIMMUNITY HIGHLIGHTS 2016; 7:8. [PMID: 27395414 PMCID: PMC4939145 DOI: 10.1007/s13317-016-0081-2] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2016] [Accepted: 06/23/2016] [Indexed: 01/16/2023]
Abstract
PURPOSE The dense fine speckled (DFS) pattern as detected by indirect immunofluorescence (IIF) on HEp-2 cells has been associated with several inflammatory diseases but is most commonly observed in individuals that do not have an antinuclear antibody (ANA)-associated rheumatic disease and even in apparently healthy individuals. Consequently, the accurate identification and correct reporting of this IIF pattern is of utmost importance and accordingly has been recognized by several international study groups for the detection of ANA. Furthermore, the DFS IIF pattern has recently been recommended as a competency level recognition pattern by the International Consensus on Antinuclear Antibody (ANA) Pattern (ICAP, http://www.anapatterns.org/ ) Committee. The objective of this study was to use an internet-based survey to assess how accurately the DFS IIF pattern was recognized by experienced technologists. METHODS High-resolution digital IIF images were captured using the automated IIF NOVA View instrument (Inova Diagnostics, San Diego, CA). Ten images were posted in an anonymous, international, internet-based interpretive survey. Two hundred and thirty IIF technologists were invited to participate. Four of the images in the survey were from previously characterized serum samples with classical ANA IIF patterns (nucleolar, centromere, homogeneous, and speckled) and two of the images were from samples with a DFS IIF ANA pattern and isolated anti-DFS70 antibodies as determined by a chemiluminescence immunoassay. The remaining four images were from sera with the classic IIF ANA patterns referred to above and mixed with a monospecific anti-DFS70-positive sample. The survey included multiple choice selections: homogeneous, DFS, centromere, nucleolar, speckled, other, or unrecognizable. RESULTS 125 of the 230 participants who completed the survey had diverse levels of experience in IIF pattern recognition on HEp-2 cells ranging from <1 year to >10 years of experience (average >10 years). Participants had a high concordance in correctly classifying the classical ANA IIF patterns: ranging from 95.2 % for centromere to 74.4 % for nucleolar patterns. The unmixed DFS pattern was recognized with significantly lower accuracy (~50 %; p < 0.05). However, less than 10 % correctly identified mixed patterns derived from the sera containing both clinically relevant ANA and anti-DFS70 antibodies. CONCLUSIONS Recognizing the DFS ANA IIF pattern and mixed IIF patterns composed of DFS + clinically relevant ANA patterns poses a significant challenge. Consequently, it seems imperative that DFS-specific immunoassays should be used to confirm the presence of anti-DFS70 antibodies before definitive results are reported to physicians.
Collapse
Affiliation(s)
- Chelsea Bentow
- Department of Research and Development, Inova Diagnostics, 9900 Old Grove Road, San Diego, CA, 92131-1638, USA
| | - Marvin J Fritzler
- Cumming School of Medicine, University of Calgary, Calgary, T2N 4N1, Canada
| | - Eckart Mummert
- Department of Research and Development, Inova Diagnostics, 9900 Old Grove Road, San Diego, CA, 92131-1638, USA
| | - Michael Mahler
- Department of Research and Development, Inova Diagnostics, 9900 Old Grove Road, San Diego, CA, 92131-1638, USA.
| |
Collapse
|
14
|
Troxell ML, Houghton DC. Atypical anti-glomerular basement membrane disease. Clin Kidney J 2015; 9:211-21. [PMID: 26985371 PMCID: PMC4792615 DOI: 10.1093/ckj/sfv140] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2015] [Accepted: 11/17/2015] [Indexed: 12/23/2022] Open
Abstract
Background Anti-glomerular basement membrane (anti-GBM) disease classically presents with aggressive necrotizing and crescentic glomerulonephritis, often with pulmonary hemorrhage. The pathologic hallmark is linear staining of GBMs for deposited immunoglobulin G (IgG), usually accompanied by serum autoantibodies to the collagen IV alpha-3 constituents of GBMs. Methods Renal pathology files were searched for cases with linear anti-GBM to identify cases with atypical or indolent course. Histopathology, laboratory studies, treatment and outcome of those cases was reviewed in detail. Results Five anti-GBM cases with atypical clinicopathologic features were identified (accounting for ∼8% of anti-GBM cases in our laboratory). Kidney biopsies showed minimal glomerular changes by light microscopy; one patient had monoclonal IgG deposits in an allograft (likely recurrent). Three patients did not have detectable serum anti-GBM by conventional assays. Three patients had indolent clinical courses after immunosuppressive treatment. One patient, untreated after presenting with brief mild hematuria, re-presented after a short interval with necrotizing and crescentic glomerulonephritis. Conclusions Thorough clinicopathologic characterization and close follow-up of patients with findings of atypical anti-GBM on renal biopsy are needed. Review of the literature reveals only rare well-documented atypical anti-GBM cases to date, only one of which progressed to end-stage kidney disease.
Collapse
Affiliation(s)
- Megan L Troxell
- Department of Pathology , Oregon Health & Science University , Portland, OR , USA
| | - Donald C Houghton
- Department of Pathology , Oregon Health & Science University , Portland, OR , USA
| |
Collapse
|
15
|
Mahler M, Bentow C, Serra J, Fritzler MJ. Detection of autoantibodies using chemiluminescence technologies. Immunopharmacol Immunotoxicol 2015; 38:14-20. [PMID: 26525648 PMCID: PMC4819877 DOI: 10.3109/08923973.2015.1077461] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Context: Although autoantibody detection methods such as indirect immunofluorescence (IIF) and enzyme-linked immunosorbent assays (ELISAs) have been available for many years and are still in use the innovation of fast, fully automated instruments using chemiluminescence technology in recent years has led to rapid adoption in autoimmune disease diagnostics. In 2009, BIO-FLASH, a fully automated, random access chemiluminescent analyzer, was introduced, proceeded by the development of the QUANTA Flash chemiluminescent immunoassays (CIA) for autoimmune diagnostics. Objective: To summarize the evolution of CIAs for the detection of autoantibodies and to review their performance characteristics. Methods: Pubmed was screened for publications evaluating novel QUANTA Flash assays and how they compare to traditional methods for the detection of autoantibodies. In addition, comparative studies presented at scientific meetings were summarized. Results: Several studies were identified that compared the novel CIAs with conventional methods for autoantibody detection. The agreements ranged from moderate to excellent depending on the assay. The studies show how the CIA technology has enhanced the analytical and clinical performance characteristics of many autoantibody assays supporting both diagnosis and follow-up testing. Conclusion: CIA has started to improve the diagnostic testing of autoantibodies as an aid in the diagnosis of a broad range of autoimmune diseases.
Collapse
Affiliation(s)
| | | | - Josep Serra
- b Biokit Research & Development, Lliçà d'Amunt , Barcelona , Spain , and
| | - Marvin J Fritzler
- c Cumming School of Medicine, University of Calgary , Calgary , Canada
| |
Collapse
|
16
|
Takeuchi Y, Takeuchi E, Kamata K. A possible clue for the production of anti-glomerular basement membrane antibody associated with ureteral obstruction and hydronephrosis. Case Rep Nephrol Dial 2015; 5:87-95. [PMID: 25960997 PMCID: PMC4410589 DOI: 10.1159/000381396] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
Background Anti-glomerular basement membrane (anti-GBM) antibody-mediated glomerulonephritis (anti-GBM GN) is an autoimmune disease with rapidly progressive glomerulonephritis. Based on a case report of anti-GBM GN following hydronephrosis, we hypothesized that hydronephrosis may act as a trigger for the development of anti-GBM antibodies. Patients and Methods We evaluated 11 patients who were diagnosed with hydronephrosis. It was measured with serum anti-GBM antibody. These patients’ medical histories as well as risk factors for the development of anti-GBM antibodies and causes of hydronephrosis were reviewed. Renal function and hematuria were also considered. The serum anti-GBM antibody was measured with enzyme-linked immunosorbent assays (ELISA) or chemiluminescent enzyme immunoassays (CLEIA). Histopathological findings of renal biopsy specimens were also evaluated. Results No patient had a medical history of renal disease. Five patients had a history of smoking. Ten of the 11 patients had renal dysfunction as evidenced by serum creatinine levels of 0.85–13.8 mg/dl, while 8 patients had RBCs in their urinary sediment at the time of diagnosis for hydronephrosis. Two of the patients assessed by ELISA and CLEIA were positive for anti-GBM antibodies. In 1 of these 3 patients, anti-GBM antibodies and renal dysfunction improved upon treatment for hydronephrosis. Another of the 3 patients developed anti-GBM GN, but anti-GBM antibodies and renal dysfunction improved dramatically upon treatment. In the 3rd patient without improved hydronephrosis, anti-GBM antibodies and renal dysfunction remained unchanged. Conclusion Our results provide insights into the development of anti-GBM antibodies in patients with ureteral obstruction and hydronephrosis.
Collapse
Affiliation(s)
- Yasuo Takeuchi
- Division of Nephrology, Department of Internal Medicine, Sagamihara, Japan
| | - Emiko Takeuchi
- Department of Immunology, Kitasato University School of Medicine, Sagamihara, Japan
| | - Kouju Kamata
- Division of Nephrology, Department of Internal Medicine, Sagamihara, Japan
| |
Collapse
|
17
|
Rawn S, Miettunen P, Brown HA, Schmeling H. Purpura, petechiae, and bullae as first signs of juvenile granulomatosis with polyangiitis. Eur J Pediatr 2014; 173:1685-9. [PMID: 24677133 DOI: 10.1007/s00431-014-2298-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/22/2014] [Revised: 03/12/2014] [Accepted: 03/14/2014] [Indexed: 10/25/2022]
Abstract
UNLABELLED We present a case of a 14-year-old girl who had a severe form of granulomatosis with polyangiitis (GPA) with extensive dermatological involvement, whose initial presentation was nonspecific leading to diagnostic confusion and initial consideration of infectious and other vasculitis causes. The patient presented with fever, congestion, malaise, and sinus pain. She was diagnosed with bacterial sinusitis and treated with antibiotics. Within weeks, she developed abdominal pain, hematuria, migratory arthritis, and palpable purpura and was diagnosed with Henoch-Schonlein purpura. She went on to develop hemoptysis and progression of the rash into erosive bullae. Investigations revealed that she was ANCA positive and had pauci-immune glomerulonephritis. Given her upper airway, pulmonary and renal involvement, and antineutrophil cytoplasmic antibodies positivity, a definitive diagnosis of a severe form of GPA was made. GPA is a chronic relapsing, life threatening vasculitis that predominantly affects small vessels. CONCLUSION Our case demonstrates that GPA can present initially with nonspecific symptoms, including extensive dermatological involvement, leading to diagnostic confusion, and delays in treatment. In the case of a severe peripheral rash in the juvenile population and/or resistant upper airway symptoms, it is vital to consider a diagnosis of GPA to avoid serious organ or life threatening consequences.
Collapse
Affiliation(s)
- Saara Rawn
- Northern Ontario School of Medicine, Sudbury, Canada,
| | | | | | | |
Collapse
|
18
|
Novel clinical and diagnostic aspects of antineutrophil cytoplasmic antibodies. J Immunol Res 2014; 2014:185416. [PMID: 24995343 PMCID: PMC4068101 DOI: 10.1155/2014/185416] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2014] [Accepted: 03/06/2014] [Indexed: 12/18/2022] Open
Abstract
Antineutrophil cytoplasmic antibodies (ANCA) are the serological hallmark of some idiopathic systemic vasculitides. Besides the investigation of ANCA-associated vasculitis (AAV) and constant effort for a standardized nomenclature and classification of the AAV, a main focus of research during the last few years has been to constantly improve the performance of enzyme immunoassays. With the latest so called third generation ELISA, this goal seemed to be fulfilled. The International Consensus Statement on Testing and Reporting of ANCA gave recommendations for standardized strategies for the serological diagnosis of ANCA. New developments now target the system immanent drawbacks of the respective diagnostic methods, be it the need for batching and the long time to result for ELISA, or the high likelihood of error and subjectivity of indirect immunofluorescence (IIF). Random access technology and multiplexing for solid phase assays as well as digital imaging for IIF are tools which may help to expedite and simplify routine diagnostics in the lab and in emergency settings. Recent findings indicate that PR3-ANCA have clinical utility beyond the diagnosis of AAV. PR3-ANCA can also serve as an aid for the differentiation between ulcerative colitis (UC) and Crohn's disease (CrD) and the stratification of UC patients. This review provides a detailed review of what is known about ANCA and highlights the latest research and state-of-the-art developments in this area.
Collapse
|
19
|
Abstract
The recently concluded Tenth International Congress on Systemic Lupus Erythematosus (SLE) held in Buenos Aires was a resounding success. This overview summarizes some of the origins of the First International Congress held in Calgary, Canada in 1986, predictions offered by past Congress Presidents, and a perspective on the trends in autoantibody testing, which remains one of the key approaches to the early and accurate diagnosis of SLE. The last few decades have witnessed a remarkable proliferation of new diagnostic technologies including addressable laser bead immunoassays and, more recently, chemiluminescence and lateral flow technologies that could find a clinical niche in point-of-care diagnostics. Against the backdrop of these constantly emerging technologies, indirect immunofluorescence has remained the platform of choice for many laboratories and diagnosticians. The notion that autoantibodies are pathogenic has been challenged by evidence that some autoantibodies are protective, some may have catalytic capacity while others may be neutral or have no function at all. The latter notion of functionless or "junk" autoantibodies needs to be taken under some advisement, because there was a time when a great proportion of the human genome was considered to include "junk DNA". The butterfly as a symbol of hope and progress in SLE research over the past 27 years since the First International Congress on SLE is almost certainly to be even more appropriate when future Congresses are held in Geneva (2015), Melbourne (2017) and eventually one in 2050.
Collapse
|
20
|
|
21
|
Miyara M, Albesa R, Charuel JL, El Amri M, Fritzler MJ, Ghillani-Dalbin P, Amoura Z, Musset L, Mahler M. Clinical phenotypes of patients with anti-DFS70/LEDGF antibodies in a routine ANA referral cohort. Clin Dev Immunol 2013; 2013:703759. [PMID: 23476678 PMCID: PMC3580898 DOI: 10.1155/2013/703759] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2012] [Accepted: 12/19/2012] [Indexed: 11/25/2022]
Abstract
OBJECTIVE To analyze the clinical value of anti-DFS70 antibodies in a cohort of patients undergoing routine antinuclear antibodies (ANAs) testing. METHODS Sera with a dense fine speckled (DFS) indirect immunofluorescence (IIF) pattern from 100 consecutive patients and 100 patients with other IIF patterns were tested for anti-DFS70 antibodies by a novel chemiluminescence immunoassay (CIA) and for ANA by ANA Screen ELISA (both INOVA). RESULTS Among the 100 patients with a DFS IIF pattern, 91% were anti-DFS70 positive by CIA compared to 3% in the comparator group (P < 0.0001). The CIA and IIF titers of anti-DFS antibodies were highly correlated (rho = 0.89). ANA by ELISA was positive in 35% of patients with the DFS IIF pattern as compared to 67% of patients with other patterns (P < 0.0001). Only 12.0% of patients with DFS pattern and 13.4% with DFS pattern and anti-DFS70 antibodies detected by CIA had systemic autoimmune rheumatic disease (SARD). Only 5/91 (5.5%) patients with anti-DFS70 antibodies had SARD and their sera were negative on the ANA Screen ELISA. CONCLUSION Although anti-DFS70 antibodies cannot exclude the presence of SARD, the likelihood is significantly lower than in patients with other IIF patterns and should be included in test algorithms for ANA testing.
Collapse
Affiliation(s)
- Makoto Miyara
- Department of Immunology, (AP-HP) Pitié-Salpêtrière Hospital, Paris, France
| | - Roger Albesa
- Department of Research, INOVA Diagnostics Inc., 9900 Old Grove Road, San Diego, CA 32131-1638, USA
| | - Jean-Luc Charuel
- Department of Immunology, (AP-HP) Pitié-Salpêtrière Hospital, Paris, France
| | - Mohamed El Amri
- Department of Immunology, (AP-HP) Pitié-Salpêtrière Hospital, Paris, France
| | | | | | - Zahir Amoura
- Department of Internal Medicine, (AP-HP) Pitié-Salpêtrière Hospital, Paris, France
| | - Lucile Musset
- Department of Immunology, (AP-HP) Pitié-Salpêtrière Hospital, Paris, France
| | - Michael Mahler
- Department of Research, INOVA Diagnostics Inc., 9900 Old Grove Road, San Diego, CA 32131-1638, USA
| |
Collapse
|
22
|
Mahler M, Parker T, Peebles CL, Andrade LE, Swart A, Carbone Y, Ferguson DJ, Villalta D, Bizzaro N, Hanly JG, Fritzler MJ. Anti-DFS70/LEDGF antibodies are more prevalent in healthy individuals compared to patients with systemic autoimmune rheumatic diseases. J Rheumatol 2012; 39:2104-10. [PMID: 22942262 DOI: 10.3899/jrheum.120598] [Citation(s) in RCA: 110] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
OBJECTIVE Antinuclear antibodies (ANA) are a serological hallmark of systemic autoimmune rheumatic diseases (SARD) such as systemic lupus erythematosus (SLE). While a number of ANA patterns detected by indirect immunofluorescence (IIF) have diagnostic significance, autoantibodies producing the dense fine speckled (DFS) pattern have been reported to be more prevalent in healthy individuals than in SARD. METHODS Sequential samples submitted for ANA testing were screened for anti-DFS antibodies by IIF (n = 3263). Samples with the DFS pattern were tested for anti-DFS70/lens epithelium-derived growth factor (LEDGF) antibodies by ELISA and by a novel chemiluminescence assay (CIA, Quanta Flash DFS70). Sera from patients with various diseases and healthy individuals were tested for anti-DFS70/LEDGF antibodies by CIA. A cohort of 251 patients with SLE was used to analyze serological and clinical associations of anti-DFS70 antibodies. RESULTS The frequency of anti-DFS antibodies by IIF was 1.62%. The prevalence of anti-DFS70/LEDGF antibodies as detected by CIA in the different cohorts was 8.9% in healthy individuals, 2.8% in SLE, 2.6% in rheumatoid arthritis, 4.0% in asthma, 5.0% in interstitial cystitis, 1.7% in Graves' disease, and 6.0% in Hashimoto's thyroiditis. Of note, the prevalence of anti-DFS70/LEDGF antibodies was significantly higher in healthy individuals compared to patients with SARD (p = 0.00085). In SLE results, anti-DFS70/LEDGF antibodies were not significantly associated with clinical features or other autoantibodies typically found in SLE. Only 1/7 SLE sera showed anti-DFS70/LEDGF, but no other autoantibody reactivity. CONCLUSION "Monospecific" anti-DFS70/LEDGF antibodies may represent a biomarker for differentiating SARD from non-SARD individuals, but there is a need for a reliable assay to ensure reactivity to DFS70.
Collapse
Affiliation(s)
- Michael Mahler
- Department of Research, Inova Diagnostics Inc., San Diego, California, USA.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
23
|
Fritzler MJ. Toward a new autoantibody diagnostic orthodoxy: understanding the bad, good and indifferent. AUTO- IMMUNITY HIGHLIGHTS 2012; 3:51-8. [PMID: 26000127 PMCID: PMC4389070 DOI: 10.1007/s13317-012-0030-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 03/04/2012] [Accepted: 03/07/2012] [Indexed: 02/07/2023]
Abstract
Rapid advances in diagnostic technologies used to detect autoantibodies have made it difficult for even the most modern laboratory to keep abreast of the changing approaches and platforms, not to mention the clinicians who are hard pressed to keep abreast of evolving diagnostic paradigms attended by these newer techniques. While autoantibody testing is traditionally considered to be primarily serving the realm of diagnostic medicine, there is little doubt that autoantibodies are also being recognized as an approach to providing prognostic and therapeutic information. Accordingly, along with related proteomics, genomics and metabolomics, it is taking on increasing importance in the realm of personalized medicine. In today's world of autoantibody diagnostics, overarching concerns about false-negative and false-positive autoantibodies tests cannot be summarily dismissed by citing pros or cons of any one technology or diagnostic platform, but often point to persisting gaps in our knowledge about, and understanding of, the origin and roles of autoantibodies. Before we can hope to completely understand the enigmas that attend the results of autoantibody diagnostic tests, perhaps it is time to step back and re-examine long-accepted paradigms and beliefs. This review will address some of the issues that impact on autoantibody detection technologies and some of the considerations and issues that will attend a new orthodoxy of autoantibody diagnostics. These issues will be addressed in the context of "bad" (pathogenic), "good" (protective) or "indifferent" (no apparent role in disease) autoantibodies.
Collapse
Affiliation(s)
- Marvin J. Fritzler
- Faculty of Medicine, University of Calgary, 3330 Hospital Dr. NW, Calgary, AB T2N 4N1 Canada
| |
Collapse
|
24
|
Ghillani P, Dufat L, Himeur S, Miyara M, Amoura Z, Musset L. Routine use of Zenit RA, a novel chemiluminescent immunoanalyzer in autoimmune disease diagnosis. AUTO- IMMUNITY HIGHLIGHTS 2012; 3:27-31. [PMID: 26000125 PMCID: PMC4389018 DOI: 10.1007/s13317-012-0032-5] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/26/2011] [Accepted: 03/09/2012] [Indexed: 12/17/2022]
Abstract
The detection of antibodies is useful to diagnose and/or to classify autoimmune diseases as connective tissue diseases and vasculitis. Zenit RA is a fully automated immunoanalyzer. The aim of this study was to compare the predictive and discriminative performance of the Zenit RA anti-cyclic citrullinated peptide (CCP), anti-cardiolipin (aCL) and anti-β 2 glycoprotein 1 (aB2GP1) tests to conventional ELISAs on clinically well-defined groups of patients and to daily evaluate the determination of anti-extractable nuclear antigen (ENA), anti-double stranded DNA (dsDNA), anti-myeloperoxidase (MPO) and anti-proteinase 3 (PR3) antibodies in a hospital laboratory. Reagents available on Zenit RA analyzer exhibit good diagnostic performances, regarding sensitivity, specificity, positive and negative predictive values. Global agreements between Zenit RA and conventional tests were from 90 to 98 % (Kappa-values ranging 0.56-0.94): 96 % for anti-CCP, 90-94 % for aCL and aB2GP1, 94 % for anti-dsDNA, 97 % for anti-ENA, 98 % for anti-MPO and 95 % for anti-PR3 antibodies. Zenit RA analyzer is easy to rapidly detect the most common autoantibodies in autoimmune diseases. This system has a potential to provide clinically useful data within a short time. Because of the flexibility of its work modalities, it is well adapted to determine antigenic specificities in daily practice.
Collapse
Affiliation(s)
- P. Ghillani
- Department of Immunology, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique–Hôpitaux de Paris, Paris, France
- Laboratoire d’Immunochimie, Département d’Immunologie, Groupe Hospitalier Pitié-Salpêtrière, 83 bld de l’Hôpital, 75013 Paris, France
| | - L. Dufat
- Department of Immunology, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique–Hôpitaux de Paris, Paris, France
| | - S. Himeur
- Department of Immunology, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique–Hôpitaux de Paris, Paris, France
| | - M. Miyara
- Department of Immunology, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique–Hôpitaux de Paris, Paris, France
| | - Z. Amoura
- Department of Internal Medicine, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique–Hôpitaux de Paris, Paris, France
| | - L. Musset
- Department of Immunology, Groupe Hospitalier Pitié-Salpêtrière, Assistance Publique–Hôpitaux de Paris, Paris, France
| |
Collapse
|