1
|
Xie N, Zhou Z, Fröch JE, Carson MD, Majumdar A, Seibel EJ, Böhringer KF. Inverse-designed large field-of-view polychromatic metalens for tri-color scanning fiber endoscopy. COMMUNICATIONS ENGINEERING 2025; 4:53. [PMID: 40108330 PMCID: PMC11923133 DOI: 10.1038/s44172-025-00377-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2024] [Accepted: 02/17/2025] [Indexed: 03/22/2025]
Abstract
Metalenses, with their ultrathin thicknesses and their ease for achieving ultra small diameters, offer a promising alternative to refractive lenses in miniaturized imaging systems, such as endoscopes, potentially enabling applications in tightly confined spaces. However, traditional metalenses suffer from strong chromatic aberrations, limiting their utility in multi-color imaging. To address this limitation, here we present an inverse-designed polychromatic metalens with a diameter of 680 μm, focal length of 400 μm, and low dispersion across 3 distinct wavelengths at 643 nm, 532 nm, and 444 nm. The metalens collimates and steers light emitted from a scanning fiber tip, generating scanning beams across a 70° field-of-view to provide illumination for a scan-based imaging. The metalens provides a close-to-diffraction-limited 0.5° angular resolution, only restricted by the effective aperture of the system. The average relative efficiency among three design wavelengths is around 32% for on-axis angle and 13% averaged across the entire field-of-view. This work holds promise for the application of metalenses in endoscopes and other miniaturized imaging systems.
Collapse
Affiliation(s)
- Ningzhi Xie
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA, USA
| | - Zhihao Zhou
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA, USA
| | - Johannes E Fröch
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA, USA
- Department of Physics, Seattle, Washington, USA
| | - Matthew D Carson
- Human Photonics Lab, Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Arka Majumdar
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA, USA.
- Department of Physics, Seattle, Washington, USA.
| | - Eric J Seibel
- Human Photonics Lab, Department of Mechanical Engineering, University of Washington, Seattle, WA, USA
| | - Karl F Böhringer
- Department of Electrical and Computer Engineering, University of Washington, Seattle, WA, USA
- Department of Bioengineering, University of Washington, Seattle, WA, USA
- Institute for Nano-Engineered Systems, University of Washington, Seattle, WA, USA
| |
Collapse
|
2
|
Lawson J, Veliky M, Abah CP, Dietrich MS, Chitale R, Simaan N. Endovascular Detection of Catheter-Thrombus Contact by Vacuum Excitation. IEEE Trans Biomed Eng 2024; 71:1926-1936. [PMID: 38241109 PMCID: PMC11232506 DOI: 10.1109/tbme.2024.3356390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2024]
Abstract
OBJECTIVE The objective of this work is to introduce and demonstrate the effectiveness of a novel sensing modality for contact detection between an off-the-shelf aspiration catheter and a thrombus. METHODS A custom robotic actuator with a pressure sensor was used to generate an oscillatory vacuum excitation and sense the pressure inside the extracorporeal portion of the catheter. Vacuum pressure profiles and robotic motion data were used to train a support vector machine (SVM) classification model to detect contact between the aspiration catheter tip and a mock thrombus. Validation consisted of benchtop accuracy verification, as well as user study comparison to the current standard of angiographic presentation. RESULTS Benchtop accuracy of the sensing modality was shown to be 99.67%. The user study demonstrated statistically significant improvement in identifying catheter-thrombus contact compared to the current standard. The odds ratio of successful detection of clot contact was 2.86 (p = 0.03) when using the proposed sensory method compared to without it. CONCLUSION The results of this work indicate that the proposed sensing modality can offer intraoperative feedback to interventionalists that can improve their ability to detect contact between the distal tip of a catheter and a thrombus. SIGNIFICANCE By offering a relatively low-cost technology that affords off-the-shelf aspiration catheters as clot-detecting sensors, interventionalists can improve the first-pass effect of the mechanical thrombectomy procedure while reducing procedural times and mental burden.
Collapse
Affiliation(s)
- Jared Lawson
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN 37235, USA
| | - Madison Veliky
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN 37235, USA
| | | | - Mary S. Dietrich
- Department of Biostatistics, Vanderbilt University Medical Center, Nashville, TN 37235, USA
| | - Rohan Chitale
- Department of Neurological Surgery, Vanderbilt University Medical Center, Nashville, TN 37235, USA
| | - Nabil Simaan
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN 37235, USA
| |
Collapse
|
3
|
Srinivasan VM, Lazaro TT, Srivatsan A, Cooper P, Phillips M, Garcia R, Chen SR, Johnson JN, Burkhardt JK, Collins DE, Kan P. Applications of a Novel Microangioscope for Neuroendovascular Intervention. AJNR Am J Neuroradiol 2020; 42:347-353. [PMID: 33361372 DOI: 10.3174/ajnr.a6900] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2020] [Accepted: 09/05/2020] [Indexed: 11/07/2022]
Abstract
BACKGROUND AND PURPOSE Visualization in neuroendovascular intervention currently relies on biplanar fluoroscopy and contrast administration. With the advent of endoscopy, direct visualization of the intracranial intravascular space has become possible with microangioscopes. We analyzed the efficacy of our novel microangioscope to enable direct observation and inspection of the cerebrovasculature, complementary to a standard fluoroscopic technique. MATERIALS AND METHODS Iterations of microangioscopes were systematically evaluated for use in neurodiagnostics and neurointerventions in both live animal and human cadaveric models. Imaging quality, trackability, and navigability were assessed. Diagnostic procedures assessed included clot identification and differentiation, plaque identification, inspection for vessel wall injury, and assessment of stent apposition. Interventions performed included angioscope-assisted stent-retriever thrombectomy, clot aspiration, and coil embolization. RESULTS The microangioscope was found helpful in both diagnosis and interventions by independent evaluators. Mean ratings of the imaging quality on a 5-point scale ranged from 3.0 (clot identification) to 4.7 (Pipeline follow-up). Mean ratings for clinical utility ranged from 3.0 (aspiration thrombectomy) to 4.7 (aneurysm treatment by coil embolization and WEB device). CONCLUSIONS This fiber optic microangioscope can safely navigate and visualize the intravascular space in human cadaveric and in vivo animal models with satisfactory resolution. It has potential value in diagnostic and neurointerventional applications.
Collapse
Affiliation(s)
- V M Srinivasan
- From the Department of Neurosurgery (V.M.S., T.T.L., A.S., R.G., J.N.J., J.-K.B., P.K.)
| | - T T Lazaro
- From the Department of Neurosurgery (V.M.S., T.T.L., A.S., R.G., J.N.J., J.-K.B., P.K.)
| | - A Srivatsan
- From the Department of Neurosurgery (V.M.S., T.T.L., A.S., R.G., J.N.J., J.-K.B., P.K.)
| | - P Cooper
- Vena Medical (P.C., M.P.), Kitchener, Ontario, Canada
| | - M Phillips
- Vena Medical (P.C., M.P.), Kitchener, Ontario, Canada
| | - R Garcia
- From the Department of Neurosurgery (V.M.S., T.T.L., A.S., R.G., J.N.J., J.-K.B., P.K.)
| | - S R Chen
- Department of Interventional Radiology (S.R.C.), The MD Anderson Cancer Center, Houston, Texas
| | - J N Johnson
- From the Department of Neurosurgery (V.M.S., T.T.L., A.S., R.G., J.N.J., J.-K.B., P.K.)
| | - J-K Burkhardt
- From the Department of Neurosurgery (V.M.S., T.T.L., A.S., R.G., J.N.J., J.-K.B., P.K.)
| | - D E Collins
- Center for Comparative Medicine (D.E.C.) Baylor College of Medicine, Houston, Texas
| | - P Kan
- From the Department of Neurosurgery (V.M.S., T.T.L., A.S., R.G., J.N.J., J.-K.B., P.K.)
| |
Collapse
|
4
|
Lazaro T, Srinivasan VM, Cooper P, Phillips M, Garcia R, Chen SR, Johnson J, Collins DE, Kan P. A new set of eyes: development of a novel microangioscope for neurointerventional surgery. J Neurointerv Surg 2019; 11:1036-1039. [PMID: 30878951 DOI: 10.1136/neurintsurg-2018-014610] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 02/07/2019] [Accepted: 02/09/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND Endovascular technological advances have revolutionized the field of neurovascular surgery and have become the mainstay of treatment for many cerebrovascular pathologies. Digital subtraction angiography (DSA) is the 'gold standard' for visualization of the vasculature and deployment of endovascular devices. Nonetheless, with recent technological advances in optics, angioscopy has emerged as a potentially important adjunct to DSA. Angioscopy can offer direct visualization of the intracranial vasculature, and direct observation and inspection of device deployment. However, previous iterations of this technology have not been sufficiently miniaturized or practical for modern neurointerventional practice. OBJECTIVE To describe the evolution, development, and design of a microangioscope that offers both high-quality direct visualization and the miniaturization necessary to navigate in the small intracranial vessels and provide examples of its potential applications in the diagnosis and treatment of cerebrovascular pathologies using an in vivo porcine model. METHODS In this proof-of-concept study we introduce a novel microangioscope, designed from coherent fiber bundle technology. The microangioscope is smaller than any previously described angioscope, at 1.7 F, while maintaining high-resolution images. A porcine model is used to demonstrate the resolution of the images in vivo. RESULTS Video recordings of the microangioscope show the versatility of the camera mounted on different microcatheters and its ability to navigate external carotid artery branches. The microangioscope is also shown to be able to resolve the subtle differences between red and white thrombi in a porcine model. CONCLUSION A new microangioscope, based on miniaturized fiber optic technology, offers a potentially revolutionary way to visualize the intracranial vascular space.
Collapse
Affiliation(s)
- Tyler Lazaro
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| | | | | | | | - Robert Garcia
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| | - Stephen R Chen
- Radiology, Baylor College of Medicine, Houston, Texas, USA
| | - Jeremiah Johnson
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| | - Dalis E Collins
- Center for Comparative Medicine, Baylor College of Medicine, Houston, Texas, USA
| | - Peter Kan
- Department of Neurosurgery, Baylor College of Medicine, Houston, Texas, USA
| |
Collapse
|
5
|
Savastano LE, Seibel EJ. Scanning Fiber Angioscopy: A Multimodal Intravascular Imaging Platform for Carotid Atherosclerosis. Neurosurgery 2017; 64:188-198. [PMID: 28899060 DOI: 10.1093/neuros/nyx322] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2017] [Accepted: 08/01/2017] [Indexed: 01/28/2023] Open
Affiliation(s)
- Luis E Savastano
- Department of Neurosurgery, University of Michigan, Ann Arbor, Michigan
| | - Eric J Seibel
- Department of Mechanical Engineering, University of Washington, Seattle, Washington
| |
Collapse
|
6
|
Multimodal laser-based angioscopy for structural, chemical and biological imaging of atherosclerosis. Nat Biomed Eng 2017. [PMID: 28555172 DOI: 10.1038/s41551-016-0023.] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The complex nature of atherosclerosis demands high-resolution approaches to identify subtle thrombogenic lesions and define the risk of plaque rupture. Here, we report the proof-of-concept use of a multimodal scanning fiber endoscope (SFE) consisting of a single optical fiber scanned by a piezoelectric drive that illuminates tissue with red, blue, and green laser beams, and digitally reconstructs images at 30 Hz with high resolution and large fields-of-view. By combining laser-induced reflectance and fluorescence emission of intrinsic fluorescent constituents in arterial tissues, the SFE allowed us to co-generate endoscopic videos with a label-free biochemical map to derive a morphological and spectral classifier capable of discriminating early, intermediate, advanced, and complicated atherosclerotic plaques. We demonstrate the capability of scanning fiber angioscopy for the molecular imaging of vulnerable atherosclerosis by targeting proteolytic activity with a fluorescent probe activated by matrix metalloproteinases. We also show that the SFE generates high-quality spectral images in vivo in an animal model with medium-sized arteries. Multimodal laser-based angioscopy could become a platform for the diagnosis, prognosis, and image-guided therapy of atherosclerosis.
Collapse
|
7
|
Multimodal laser-based angioscopy for structural, chemical and biological imaging of atherosclerosis. Nat Biomed Eng 2017; 1. [PMID: 28555172 DOI: 10.1038/s41551-016-0023] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
The complex nature of atherosclerosis demands high-resolution approaches to identify subtle thrombogenic lesions and define the risk of plaque rupture. Here, we report the proof-of-concept use of a multimodal scanning fiber endoscope (SFE) consisting of a single optical fiber scanned by a piezoelectric drive that illuminates tissue with red, blue, and green laser beams, and digitally reconstructs images at 30 Hz with high resolution and large fields-of-view. By combining laser-induced reflectance and fluorescence emission of intrinsic fluorescent constituents in arterial tissues, the SFE allowed us to co-generate endoscopic videos with a label-free biochemical map to derive a morphological and spectral classifier capable of discriminating early, intermediate, advanced, and complicated atherosclerotic plaques. We demonstrate the capability of scanning fiber angioscopy for the molecular imaging of vulnerable atherosclerosis by targeting proteolytic activity with a fluorescent probe activated by matrix metalloproteinases. We also show that the SFE generates high-quality spectral images in vivo in an animal model with medium-sized arteries. Multimodal laser-based angioscopy could become a platform for the diagnosis, prognosis, and image-guided therapy of atherosclerosis.
Collapse
|