1
|
Stadtmann H, Figel M, Grimbergen T, McWhan A, Romero AM. EURADOS intercomparisons on whole-body dosemeters for photons from 2008 to 2020: analysis and comparison of general results. RADIATION PROTECTION DOSIMETRY 2023; 199:1754-1758. [PMID: 37819293 DOI: 10.1093/rpd/ncac242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 09/19/2022] [Accepted: 09/26/2022] [Indexed: 10/13/2023]
Abstract
Starting in 2008 the European Dosimetry Group (EURADOS) has been performing international intercomparisons (ICs) on photon whole-body dosemeters for individual monitoring services. These ICs have been organized (on a biennial basis) starting 2008 up to 2020 now, each time with a similar set-up but with small alterations in the subsequent irradiation plans. The response for Hp(10) and Hp(0.07) was tested for different radiation qualities, angles of incidences (0°-60°) within a wide range of dose values (0.5-500 mSv), to check energy and angular response, linearity, reproducibility and mixed-field response. Within the last 12 years almost 15 000 whole body dosemeters have been irradiated and the corresponding response values evaluated. With an increasing number of participants and participating systems (from 62 to 132), this IC program has become an important tool for individual monitoring services to test their whole-body dosimetry systems, compare their results with other services or systems and to improve the quality of their dosimetry. The paper presents and compares the general results of these seven ICs and analyses the dosimetric results for the participating system types.
Collapse
Affiliation(s)
- Hannes Stadtmann
- Seibersdorf Labor GmbH, Radiation Protection Dosimetry, A-2444 Seibersdorf, Austria
| | - Markus Figel
- Mirion Technologies (AWST) GmbH, Auswertungsstelle, Otto-Hahn-Ring 6, D-81739 München, Germany
| | - Tom Grimbergen
- Mirion Dosimetry Services, PO Box 60067, 6800 JB Arnhem, The Netherlands
| | - Andrew McWhan
- Charthouse Data Management Limited, Unit A17 Admiralty Park, Poole BH16 6HX, UK
| | - Ana Maria Romero
- CIEMAT, Radiation Dosimetry, Avda Complutense 40, 28040 Madrid, Spain
| |
Collapse
|
2
|
Feng CJ, Wu CH, Huang YH, Chu CH, Lien KY, Wang YC, Lee SH, Hsu SM. Results of the performance test for quality assessment of personal radiation dosimetry services including the influence of the dosimeter readout frequency. Sci Rep 2022; 12:20133. [PMID: 36418355 PMCID: PMC9684117 DOI: 10.1038/s41598-022-23942-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 11/08/2022] [Indexed: 11/24/2022] Open
Abstract
This study was to determine the significance of factors considered for the measurement accuracy of personal dosimeter in dosimetry services such as dosimetry service, irradiation category, years of use and readout frequency. The investigation included management information questionnaire, on-site visit and blind test. The blind test with random selected personal badge was used in inter-comparison of eight dosimetry services, and the test results followed ANSI/HPS N13.11 criteria. This study also analyzed the measurement deviations if they felt in the criteria of ICRP 75 or not. One-way ANOVA tests were used to analyze the significant difference of the measurement deviations in different dosimetry services, irradiation categories, and years of use. Simple linear-regression test was performed for the significance of the prediction model between measurement deviations and readout frequencies. All visited dosimetry services followed the proper statue of basic management and passed the performance check of the tolerance level. The average deviations corresponding to category I, category II deep dose, and category II shallow dose were 6.08%, 9.49%, and 10.41% respectively. There had significant differences of measurement deviation in different dosimetry services (p < 0.0001) and irradiation categories (p = 0.016) but no significant difference in years of use (p = 0.498). There was no significance in the linear-regression model between measurement deviation and badge readout frequencies. Based on the regular calibration of the personal dosimeter, the deviation of the measured value is mainly affected by different dosimetry services and irradiation categories; and there shows no significant influence by years of use and readout frequency.
Collapse
Affiliation(s)
- Chen-Ju Feng
- Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan, Republic of China, 112
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, 112, Taiwan, Republic of China
| | - Chin-Hui Wu
- Department of Medical Imaging and Radiological Sciences, Tzu-Chi University of Science and Technology, Hualien, Taiwan, Republic of China, 970
| | - Yi-Hui Huang
- Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan, Republic of China, 112
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, 112, Taiwan, Republic of China
- Department of Radiation Protection, Atomic Energy Commission, New Taipei City, Taiwan, Republic of China, 234
| | - Chien-Hau Chu
- Health Physics Division, Institute of Nuclear Energy Research, Taoyuan City, Taiwan, Republic of China, 325
| | - Ke-Yu Lien
- Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan, Republic of China, 112
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, 112, Taiwan, Republic of China
| | - Yu-Chieh Wang
- Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan, Republic of China, 112
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, 112, Taiwan, Republic of China
| | - Shen-Hao Lee
- Chinese Society of Medical Physics, Taipei, Taiwan, Republic of China, 110
- Department of Radiation Oncology, Chang Gung Memorial Hospital, Taoyuan City, Taiwan, Republic of China, 333
| | - Shih-Ming Hsu
- Medical Physics and Radiation Measurements Laboratory, National Yang Ming Chiao Tung University, Taipei, Taiwan, Republic of China, 112.
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei, 112, Taiwan, Republic of China.
- Chinese Society of Medical Physics, Taipei, Taiwan, Republic of China, 110.
| |
Collapse
|
3
|
Stadtmann H, Grimbergen TWM, Figel M, Romero AM, McWhan AF. Results of the EURADOS extremity dosemeter intercomparison 2009. RADIATION PROTECTION DOSIMETRY 2011; 144:275-281. [PMID: 21196458 DOI: 10.1093/rpd/ncq504] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
This paper presents the results of an intercomparison for extremity dosemeters organised by the European radiation dosimetry group in 2009. In total, 59 systems were tested during this exercise including ring, stall and wrist dosemeters. A total of 1652 dosemeters were irradiated in the selected fields of photons and beta radiation qualities on appropriate phantoms (ISO finger and pillar phantom) in the dose quantity H(p)(0.07). All irradiations were carried out in selected accredited reference dosemetry laboratories (Seibersdorf Laboratories, Austria and IRSN, France). The results show that, especially at low-energy beta radiations ((85)Kr) and for beta irradiations with large angles of incidence (60°), many tested systems show pronounced under responses. On the other hand, for photon irradiations down to energies of 16 keV most systems showed good results. A participants meeting was held at IM2010 with discussion on both general aspects of this intercomparison and specific problems.
Collapse
Affiliation(s)
- H Stadtmann
- Seibersdorf Labor GmbH, Radiation Safety and Applications, Dosimetry, Seibersdorf, Austria.
| | | | | | | | | |
Collapse
|