1
|
Clinical benchmarking of a commercial software for skin dose estimation in cardiac, abdominal, and neurology interventional procedures. Med Phys 2024; 51:3687-3697. [PMID: 38277471 DOI: 10.1002/mp.16956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Revised: 01/09/2024] [Accepted: 01/16/2024] [Indexed: 01/28/2024] Open
Abstract
BACKGROUND Radiation exposure from interventional radiology (IR) could lead to potential risk of skin injury in patients. Several dose monitoring software like radiation dose monitor (RDM) were developed to estimate the patient skin dose (PSD) distribution in IR. PURPOSE This study benchmarked the accuracy of RDM software in estimating PSD as compared to GafChromic film baseline in-vivo measurements on patients during cardiac, abdominal, and neurology IR procedures. METHODS The prospective study conducted in four IR departments included 81 IR procedures (25 cardiac, 31 abdominal, and 25 neurology procedures) on three angiographic systems. PSD and field geometry were measured by placing GafChromic film under the patient's back. Statistical analyses were performed to compare the software estimation and film measurement results in terms of PSD and geometric accuracy. RESULTS Median values of measured/calculated PSD were 1140/1005, 591/655.9, and 538/409.7 mGy for neurology, cardiac, and abdominal procedures, respectively. For all angiographic systems, the median (InterQuartile Range, IQR) difference between calculated and measured PSD was -10.2% (-21.8%-5.7%) for neurology, -4.5% (-19.5%-15.5%) for cardiac, and -21.9% (-38.7%--3.6%) for abdominal IR procedures. These differences were not significant for all procedures (p > 0.05). Discrepancies increased up to -82% in lower dose regions where the measurement uncertainties are higher. Regarding the geometric accuracy, RDM correctly reproduced the skin dose map and estimated PSD area dimensions closely matched those registered on films with a median (IQR) difference of 0 cm (-1-0.8 cm). CONCLUSIONS RDM is proved to be a useful solution for the estimation of PSD and skin dose distribution during abdominal, cardiac and neurology IR procedures despite a geometry phantom which is not specific to the latter type of IR procedures.
Collapse
|
2
|
Patient skin dose measurement and risk of deterministic effect during fluoroscopy cardiac procedures. RADIATION PROTECTION DOSIMETRY 2023; 199:2053-2060. [PMID: 37491996 DOI: 10.1093/rpd/ncad206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 06/19/2023] [Accepted: 06/25/2023] [Indexed: 07/27/2023]
Abstract
This study aimed at assessing patient's peak skin doses (PSD) during fluoroscopy cardiac procedures and proposed a look up table to enhance patient's dose management. Perspex phantom and thermoluminescent dosemeters (TLD) were irradiated for different dose levels with X-ray equipment (Philips Azurion 7). It was found that PSD measures were higher than the kerma at the interventional reference point [K (IRP)] reported with factors 1.55, 1.75 and 2.88 for anterior posterior (AP0o), left anterior oblique (LAO45o) and right anterior oblique (RAO45o), respectively. The equations describing the correlation between the PSD measured kerma area product and cumulative air kerma were found with R-square values of 0.98 and 0.99, respectively. The statistical analysis shows a strong linear correlation between PSD and K (IRP) (P-value = 0.05). It was also found that 27% of the patients population considered in this work, received a skin dose higher than the threshold of deterministic effect of 2 Gy and a look up table with the equation of fitness were proposed to be implemented in the facility for K (IRP) higher than 500 mGy.
Collapse
|
3
|
On-line estimated peak skin dose during percutaneous coronary intervention for chronic total occlusion using new patient dose mapping technology. Arch Cardiovasc Dis 2022; 115:436-447. [PMID: 35840491 DOI: 10.1016/j.acvd.2022.04.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Revised: 04/20/2022] [Accepted: 04/25/2022] [Indexed: 11/29/2022]
Abstract
BACKGROUND X-ray exposure during complex percutaneous coronary intervention is a very important issue. AIM To reduce patient peak skin dose during percutaneous coronary intervention procedures for chronic total occlusion using on-line estimated peak skin dose software (Dose Map). METHODS Throughout the procedure, Dose Map provided a map of local cumulative peak skin dose. This map was displayed in-room from 1Gy cumulative air kerma, and was updated every 0.5Gy. The operator's actions to minimize deterministic risks following map notification were collected. Skin reaction was evaluated 3 months after the procedure. A comparison with our historical X-ray exposure data (207 patients from January 2013 to July 2014) was performed. RESULTS From November 2015 to October 2016, 97 patients (Japanese chronic total occlusion score 2.1±1.1; 100 percutaneous coronary intervention procedures for chronic total occlusion) were prospectively enrolled. Fluoroscopy time was 40.8 (21.6-60.3) minutes, cumulative air kerma 1884 (1144-3231) mGy, estimated peak skin dose 962 (604-1474) mGy and kerma area product 115.8 (71.5-206.7) Gy.cm2. Cumulative air kerma was>3Gy in 28% of cases, and>5Gy in 11% of cases. In 68% of cases, at least one action was taken by the operator after map notification to optimize skin dose distribution. Main changes included: gantry angulation (52%); field of view (25%); and collimation (13%). No skin injuries were observed at follow-up. In comparison with our chronic total occlusion historical radiation data, median cumulative air kerma and kerma area product were reduced by 31% and 33%, respectively (P<0.005. CONCLUSION Online skin dose mapping software allows the distribution of patient skin dose during complex percutaneous coronary intervention procedures, and may minimize X-ray exposure.
Collapse
|
4
|
Comparison of peak skin dose and dose map obtained with real-time software and radiochromic films in patients undergoing abdominopelvic embolization. Diagn Interv Imaging 2022; 103:338-344. [DOI: 10.1016/j.diii.2022.01.010] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2022] [Revised: 01/24/2022] [Accepted: 01/25/2022] [Indexed: 11/29/2022]
|
5
|
MEASUREMENT OF SKIN DOSE AND RADIATION-INDUCED CHANGES IN SKIN MICROCIRCULATION IN CHRONIC TOTAL OCCLUSION PERCUTANEOUS CARDIAC INTERVENTIONS (CTO-PCI). RADIATION PROTECTION DOSIMETRY 2021; 195:257-263. [PMID: 33709133 DOI: 10.1093/rpd/ncab024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Revised: 02/01/2021] [Accepted: 02/05/2021] [Indexed: 06/12/2023]
Abstract
Skin injuries may occur when radiation doses to the skin exceed 2 Gy. This study aimed to measure changes in skin microcirculation in patients undergoing chronic total occlusion percutaneous coronary interventions (CTO-PCI). In 14 patients, peak skin dose (PSD) was estimated with radiographic films and skin microcirculation was assessed with laser speckle contrast imaging (LSCI), before, 1 day after the intervention, and 4-6 weeks later. The mean PSD was 1.8 ± 0.9 Gy. Peak skin microcirculation increased by 12% from 45 ± 6 PU before to 50 ± 9 PU 1 day after the intervention (p = 0.01), and returned to 46 ± 8 PU after 4-6 weeks (p = 0.15). There was no significant correlation between PSD and the change in perfusion, neither 1 day (r = -0.13, p = 0.69) nor 4-6 weeks after the intervention (r = 0.33, p = 0.35). These results suggest that there are no radiation-induced microvascular changes in the skin after CTO-PCI at skin doses below 2 Gy.
Collapse
|
6
|
Estimation of patient skin dose in fluoroscopy: summary of a joint report by AAPM TG357 and EFOMP. Med Phys 2021; 48:e671-e696. [PMID: 33930183 DOI: 10.1002/mp.14910] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2021] [Revised: 04/04/2021] [Accepted: 04/23/2021] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Physicians use fixed C-arm fluoroscopy equipment with many interventional radiological and cardiological procedures. The associated effective dose to a patient is generally considered low risk, as the benefit-risk ratio is almost certainly highly favorable. However, X-ray-induced skin injuries may occur due to high absorbed patient skin doses from complex fluoroscopically guided interventions (FGI). Suitable action levels for patient-specific follow-up could improve the clinical practice. There is a need for a refined metric regarding follow-up of X-ray-induced patient injuries and the knowledge gap regarding skin dose-related patient information from fluoroscopy devices must be filled. The most useful metric to indicate a risk of erythema, epilation or greater skin injury that also includes actionable information is the peak skin dose, that is, the largest dose to a region of skin. MATERIALS AND METHODS The report is based on a comprehensive review of best practices and methods to estimate peak skin dose found in the scientific literature and situates the importance of the Digital Imaging and Communication in Medicine (DICOM) standard detailing pertinent information contained in the Radiation Dose Structured Report (RDSR) and DICOM image headers for FGI devices. Furthermore, the expertise of the task group members and consultants have been used to bridge and discuss different methods and associated available DICOM information for peak skin dose estimation. RESULTS The report contributes an extensive summary and discussion of the current state of the art in estimating peak skin dose with FGI procedures with regard to methodology and DICOM information. Improvements in skin dose estimation efforts with more refined DICOM information are suggested and discussed. CONCLUSIONS The endeavor of skin dose estimation is greatly aided by the continuing efforts of the scientific medical physics community, the numerous technology enhancements, the dose-controlling features provided by the FGI device manufacturers, and the emergence and greater availability of the DICOM RDSR. Refined and new dosimetry systems continue to evolve and form the infrastructure for further improvements in accuracy. Dose-related content and information systems capable of handling big data are emerging for patient dose monitoring and quality assurance tools for large-scale multihospital enterprises.
Collapse
|
7
|
Accuracy of skin dose mapping in interventional cardiology: Comparison of 10 software products following a common protocol. Phys Med 2021; 82:279-294. [PMID: 33706118 DOI: 10.1016/j.ejmp.2021.02.016] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Revised: 02/19/2021] [Accepted: 02/20/2021] [Indexed: 10/21/2022] Open
Abstract
PURPOSE Online and offline software products can estimate the maximum skin dose (MSD) delivered to the patient during interventional cardiology procedures. The capabilities and accuracy of several skin dose mapping (SDM) software products were assessed on X-ray systems from the main manufacturers following a common protocol. METHODS Skin dose was measured on four X-ray systems following a protocol composed of nine fundamental irradiation set-ups and three set-ups simulating short, clinical procedures. Dosimeters/multimeters with semiconductor-based detectors, radiochromic films and thermoluminescent dosimeters were used. Results were compared with up to eight of 10 SDM products, depending on their compatibility. RESULTS The MSD estimates generally agreed with the measurements within ± 40% for fundamental irradiation set-ups and simulated procedures. Only three SDM products provided estimates within ± 40% for all tested configurations on at least one compatible X-ray system. No SDM product provided estimates within ± 40% for all combinations of configurations and compatible systems. The accuracy of the MSD estimate for lateral irradiations was variable and could be poor (up to 66% underestimation). Most SDM products produced maps which qualitatively represented the dimensions, the shape and the relative position of the MSD region. Some products, however, missed the MSD region when situated at the intersection of multiple fields, which is of radiation protection concern. CONCLUSIONS It is very challenging to establish a common protocol for quality control (QC) and acceptance testing because not all information necessary for accurate MSD calculation is available or standardised in the radiation dose structured reports (RDSRs).
Collapse
|
8
|
Validation of the MC-GPU Monte Carlo code against the PENELOPE/penEasy code system and benchmarking against experimental conditions for typical radiation qualities and setups in interventional radiology and cardiology. Phys Med 2021; 82:64-71. [PMID: 33588229 DOI: 10.1016/j.ejmp.2021.01.075] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/28/2020] [Revised: 01/20/2021] [Accepted: 01/24/2021] [Indexed: 11/23/2022] Open
Abstract
INTRODUCTION Interventional procedures are associated with potentially high radiation doses to the skin. The 2013/59/EURATOM Directive establishes that the equipment used for interventional radiology must have a device or a feature informing the practitioner of relevant parameters for assessing patient dose at the end of the procedure. Monte Carlo codes of radiation transport are considered to be one of the most reliable tools available to assess doses. However, they are usually too time consuming for use in clinical practice. This work presents the validation of the fast Monte Carlo code MC-GPU for application in interventional radiology. METHODOLOGIES MC-GPU calculations were compared against the well-validated Monte Carlo simulation code PENELOPE/penEasy by simulating the organ dose distribution in a voxelized anthropomorphic phantom. In a second phase, the code was compared against thermoluminescent measurements performed on slab phantoms, both in a calibration laboratory and at a hospital. RESULTS The results obtained from the two simulation codes show very good agreement, differences in the output were within 1%, whereas the calculation time on the MC-GPU was 2500 times shorter. Comparison with measurements is of the order of 10%, within the associated uncertainty. CONCLUSIONS It has been verified that MC-GPU provides good estimates of the dose when compared to PENELOPE program. It is also shown that it presents very good performance when assessing organ doses in very short times, less than one minute, in real clinical set-ups. Future steps would be to simulate complex procedures with several projections.
Collapse
|
9
|
Vendor-independent skin dose mapping application for interventional radiology and cardiology. J Appl Clin Med Phys 2021; 22:145-157. [PMID: 33440056 PMCID: PMC7882120 DOI: 10.1002/acm2.13167] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2020] [Revised: 08/24/2020] [Accepted: 10/09/2020] [Indexed: 11/22/2022] Open
Abstract
PURPOSE The purpose of this paper is to present and validate an originally developed application SkinCare used for skin dose mapping in interventional procedures, which are associated with relatively high radiation doses to the patient's skin and possible skin reactions. METHODS SkinCare is an application tool for generating skin dose maps following interventional radiology and cardiology procedures using the realistic 3D patient models. Skin dose is calculated using data from Digital Imaging and Communications in Medicine (DICOM) Radiation Dose Structured Reports (RDSRs). SkinCare validation was performed by using the data from the Siemens Artis Zee Biplane fluoroscopy system and conducting "Acceptance and quality control protocols for skin dose calculating software solutions in interventional cardiology" developed and tested in the frame of the VERIDIC project. XR-RV3 Gafchromic films were used as dosimeters to compare peak skin doses (PSDs) and dose maps obtained through measurements and calculations. DICOM RDSRs from four fluoroscopy systems of different vendors (Canon, GE, Philips, and Siemens) were used for the development of the SkinCare and for the comparison of skin dose maps generated using SkinCare to skin dose maps generated by different commercial software tools (Dose Tracking System (DTS) from Canon, RadimetricsTM from Bayer and RDM from MEDSQUARE). The same RDSRs generated during a cardiology clinical procedure (percutaneous coronary intervention-PCI) were used for comparison. RESULTS Validation performed using VERIDIC's protocols for skin dose calculation software showed that PSD calculated by SkinCare is within 17% and 16% accuracy compared to measurements using XR-RV3 Gafchromic films for fundamental irradiation setups and simplified clinical procedures, respectively. Good visual agreement between dose maps generated by SkinCare and DTS, RadimetricsTM and RDM was obtained. CONCLUSIONS SkinCare is proved to be very convenient solution that can be used for monitoring delivered dose following interventional procedures.
Collapse
|
10
|
Skin dose assessment in interventional radiology. Phys Med 2021; 81:170-172. [DOI: 10.1016/j.ejmp.2020.12.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2020] [Revised: 12/17/2020] [Accepted: 12/18/2020] [Indexed: 02/05/2023] Open
|
11
|
Pressure distribution analysis of X-Ray table mattresses. J Med Imaging Radiat Sci 2020; 52:97-103. [PMID: 33339756 DOI: 10.1016/j.jmir.2020.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 11/03/2020] [Accepted: 11/06/2020] [Indexed: 10/22/2022]
Abstract
BACKGROUND There is a risk of developing pressure ulcers from lying on an X-ray table mattress, if the mattress pressure redistribution properties are poor. AIM To assess the pressure redistribution properties of 'new' and 'in current clinical use' X-ray table mattresses. METHODS AND MATERIALS Twenty one X-ray table mattresses, each of 2.5 cm thickness, were evaluated. An anthropomorphic human phantom of adult stature with five different weights (minimum, first quartile, mean, third quartile and maximum) was used to simulate human head, pelvis and heels (pressure ulcer jeopardy areas). Using Xsensor technology, peak pressure was measured and Interface Pressure Ratio was calculated for the three pressure ulcer jeopardy areas 'with' and 'without' an X-ray table mattress. RESULTS For all mattresses, statistically significant differences (p < 0.05) were found between the peak pressure values with and without using an X-ray table mattress for the three pressure ulcer jeopardy areas; similarly, for all mattresses, statistically significant differences (p < 0.05) were found between the Interface Pressure Ratio values with and without using x-ray table mattress. The type and age of the mattress was observed to have an impact on peak pressure values and Interface Pressure Ratios, with older mattresses performing worse. CONCLUSION Peak pressure values and Interface Pressure Ratios are reduced significantly when using newer X-ray table mattresses. This could be because newer mattresses use more appropriate materials in their construction and/or older mattresses have lost their pressure redistribution properties. Radiology departments should consider assessing mattresses pressure redistribution properties, perhaps on an annual basis.
Collapse
|
12
|
Review of skin dose calculation software in interventional cardiology. Phys Med 2020; 80:75-83. [DOI: 10.1016/j.ejmp.2020.09.023] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 09/16/2020] [Accepted: 09/25/2020] [Indexed: 11/16/2022] Open
|
13
|
Report of AAPM Task Group 235 Radiochromic Film Dosimetry: An Update to TG‐55. Med Phys 2020; 47:5986-6025. [DOI: 10.1002/mp.14497] [Citation(s) in RCA: 64] [Impact Index Per Article: 16.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2020] [Revised: 09/15/2020] [Accepted: 09/17/2020] [Indexed: 12/12/2022] Open
|
14
|
BENCHMARKING THE DOSE MAP SOFTWARE FOR CLINICAL IMPLEMENTATION AND ESTABLISHMENT OF A LOCAL FOLLOW-UP PROTOCOL FOR THE MANAGEMENT OF SKIN INJURES FOLLOWING COMPLEX INTERVENTIONAL CARDIOLOGY PROCEDURES. RADIATION PROTECTION DOSIMETRY 2020; 190:392-399. [PMID: 32909041 DOI: 10.1093/rpd/ncaa119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Revised: 06/25/2020] [Accepted: 08/15/2020] [Indexed: 06/11/2023]
Abstract
This paper aims to validate the accuracy of the peak skin dose (Dskin,max) computed by the Dose Map software (DMS)-general electric and establish a local follow-up protocol for the management of patient skin injuries following complex interventional cardiology procedures (ICPs). Dskin,max was computed by the DMS and was simultaneously measured by a dense mesh of 72 thermoluminescent dosemeters for 20 ICP. Measured and computed Dskin,max were compared using Lin's concordance coefficient (${\rho}_c$). The implementation of a local follow-up strategy was based on a computed Dskin,max of 2 Gy. After eliminating 2 outliers, the average deviation between the two methods was 6% (range: -36 to +40%). Concordance between the two methods was moderate with ${\rho}_c$ (confidence interval) of 0.9128 (0.8541-0.9486). DMS computes Dskin,max with an acceptable accuracy and can be used to setup an individual follow-up process for patients with high skin exposure and risks.
Collapse
|
15
|
SKIN DOSE MAPPING IN INTERVENTIONAL CARDIOLOGY: A PRACTICAL SOLUTION. RADIATION PROTECTION DOSIMETRY 2020; 188:508-515. [PMID: 32614065 DOI: 10.1093/rpd/ncaa002] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Revised: 11/25/2019] [Accepted: 01/06/2020] [Indexed: 06/11/2023]
Abstract
Numerous cases of radiation-induced tissue reactions following interventional cardiology (IC) procedures have been reported, resulting in the need for an optimized and personalized dosimetry. At present, there are many fluoroscopy units without Digital Imaging and Communications in Medicine (DICOM) Radiation Dose Structured Report globally installed. Many of these have not been updated yet, and may never be, therefore, the main objectives of this paper are to develop an offline skin dose mapping application, which uses DICOM headers for the peak skin dose (PSD) assessment and to compare the PSD assessment results to XR-RV3 Gafchromic film for common IC procedures. The mean deviation between the measured and the calculated PSD was 8.7 ± 26.3%. Simulated skin dose map showed good matching with XR-RV3 Gafchromic film. The skin dose mapping application presented in this paper is an elegant solution and a suitable alternative to XR-RV3 Gafchromic film.
Collapse
|
16
|
Clinical evaluation of a dose management system-integrated 3D skin dose map by comparison with radiochromic films. Eur Radiol 2020; 30:5071-5081. [DOI: 10.1007/s00330-020-06877-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2019] [Revised: 03/17/2020] [Accepted: 04/08/2020] [Indexed: 01/28/2023]
|
17
|
Experimental evaluation of a radiation dose management system-integrated 3D skin dose map by comparison with XR-RV3 Gafchromic® films. Phys Med 2019; 66:77-87. [DOI: 10.1016/j.ejmp.2019.09.234] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 09/10/2019] [Accepted: 09/14/2019] [Indexed: 11/22/2022] Open
|
18
|
Technical Note: Characterization of x‐ray beam profiles for a fluoroscopic system incorporating copper filtration. Med Phys 2019; 46:4918-4922. [DOI: 10.1002/mp.13774] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2019] [Revised: 07/08/2019] [Accepted: 07/25/2019] [Indexed: 11/06/2022] Open
|
19
|
Physics‐driven learning of x‐ray skin dose distribution in interventional procedures. Med Phys 2019; 46:4654-4665. [DOI: 10.1002/mp.13758] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2018] [Revised: 07/16/2019] [Accepted: 07/29/2019] [Indexed: 11/09/2022] Open
|
20
|
MEASUREMENT OF PATIENT SKIN DOSE DISTRIBUTIONS IN THREE LEBANESE INTERVENTIONAL CARDIOLOGY SUITES. RADIATION PROTECTION DOSIMETRY 2019; 183:375-385. [PMID: 30165531 DOI: 10.1093/rpd/ncy152] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2018] [Revised: 06/28/2018] [Accepted: 08/02/2018] [Indexed: 06/08/2023]
Abstract
Using a mesh of 30 thermoluminescent dosemeters, adults' patient skin doses were measured for 99 coronary angiography (CA) and 89 percutaneous coronary interventions (PCI) performed in three Lebanese hospitals. Average peak skin dose (Dskin,max) were 152 mGy (range: 16-1144) for CAs and 576 mGy (range: 7-3361) for PCIs. While only four patients had a Dskin,max value exceeding the 2 Gy threshold for skin injuries, several patients had skin dose values above 1 Gy at several distinct locations proving that Dskin,max alone is not sufficient for repetitive procedures; 2D dose maps are required instead. Dskin,max correlated well with total air kerma-area product (PKA,T) for PCI in Hospitals 1 and 2 (R = 0.91 and 0.76, respectively) enabling the setup of an alert level at PKA,T = 240 and 210 Gy cm2, respectively, corresponding to a Dskin,max of 2 Gy. This was not possible for Hospital 3 due to weak correlations between Dskin,max and PKA,T.
Collapse
|
21
|
In vivo validation of Dosemap software use in interventional cardiology with dosimetrics indicators and peak skin dose evaluation. Catheter Cardiovasc Interv 2019; 94:216-222. [DOI: 10.1002/ccd.28097] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/24/2018] [Revised: 12/18/2018] [Accepted: 01/02/2019] [Indexed: 11/12/2022]
|
22
|
Benchmarking the DACS-integrated Radiation Dose Monitor® skin dose mapping software using XR-RV3 Gafchromic® films. Med Phys 2018; 45:4683-4692. [DOI: 10.1002/mp.13125] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2018] [Revised: 08/01/2018] [Accepted: 08/03/2018] [Indexed: 11/07/2022] Open
|
23
|
Patient Radiation Dose Reduction Considerations in a Contemporary Interventional Radiology Suite. Cardiovasc Intervent Radiol 2018; 41:1925-1934. [PMID: 30132101 DOI: 10.1007/s00270-018-2052-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Accepted: 08/01/2018] [Indexed: 02/07/2023]
Abstract
PURPOSE We sought to evaluate patient radiation exposure during complex liver interventional procedures performed with newer angiography equipment. MATERIALS AND METHODS We conducted a retrospective study of transjugular intrahepatic portosystemic shunt (TIPS) creations and liver tumor embolizations performed in our new angiography suite (Discovery IGS740, GE Healthcare). T tests were used to compare air kerma-area product (PKA) and reference plane air kerma (Ka,r) in the new room versus data from historical rooms and previous studies (including the RAD IR study). Results were expressed as medians [interquartile ranges (Q1, Q3)]. RESULTS From February 2015 to June 2016, 134 complex liver interventional procedures were performed in the new room, including 14 TIPS creations, 60 hepatic tumor arterial embolizations (HAEs), 26 Y90 mappings (Y90m), and 34 Y90 radioembolizations (Y90). Ka,r (Gy) values were as follows: TIPS, 0.65 (0.24, 1.15); HAE, 0.89 (0.49, 1.49); Y90m, 0.54 (0.38, 0.94); Y90, 0.46 (0.21, 1.06). PKA (Gy·cm2) values were as follows: TIPS, 148.2 (66.7, 326.5); HAE, 142.6 (88, 217.8); Y90m, 148.3 (98.2, 247); Y90, 90.8 (43.9, 161.5). Ka,r and PKA were lower in the new room than in historical rooms [Ka,r and PKA reductions: TIPS, 58 and 49%; HAE, 31 and 39%; Y90m, 58 and 52%; Y90, 49 and 56% (p < 0.05)] and versus the RAD IR study [Ka,r and PKA reductions: TIPS, 64 and 43%; HAE, 26 and 40% (p < 0.05)]. CONCLUSIONS Using the latest technology and image processing tools enables significant reduction in radiation exposure during complex liver interventional procedures.
Collapse
|
24
|
Assessment of patient's peak skin dose during abdominopelvic embolization using radiochromic (Gafchromic) films. Diagn Interv Imaging 2018; 99:321-329. [DOI: 10.1016/j.diii.2017.12.008] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2017] [Revised: 11/23/2017] [Accepted: 12/04/2017] [Indexed: 12/11/2022]
|
25
|
Developing a database of 3-D scattered radiation distributions for a c-arm fluoroscope as a function of exposure parameters and phantom. PROCEEDINGS OF SPIE--THE INTERNATIONAL SOCIETY FOR OPTICAL ENGINEERING 2018; 10573. [PMID: 29899589 DOI: 10.1117/12.2293788] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
The purpose of this work is to develop a database of 3D scattered radiation dose-rate distributions to estimate the staff dose by location around a C-Arm fluoroscopic system in an interventional procedure room. The primary x-ray beam of a Toshiba Infinix fluoroscopy machine was modeled using EGSnrc Monte Carlo code and the scattered radiation distributions were calculated using 5 × 109 photons per simulation. These 3D distributions were determined over the volume of the room as a function of various parameters such as the beam kVp and beam filter, the size and shape of the field, the angulation of the C-arm, and the phantom size and shape. Two phantom shapes were used in this study: cylindrical and super-ellipses. The results show that shape of the phantom will affect the dose-rate distribution at distances less than 100 cm, with a higher intensity for the super-ellipse. The scatter intensity per entrance air kerma is seen to be approximately proportional to field area and to increase with increasing kVp. The scatter changes proportionally with increases in primary entrance air kerma for factors such as pulse rate, mA and pulse width. This database will allow estimation of the scatter distribution in the procedure room and, when displayed to the staff during a procedure, may facilitate a reduction of occupational dose.
Collapse
|
26
|
Comparison of Patient Skin Dose Evaluated Using Radiochromic Film and Dose Calculation Software. Cardiovasc Intervent Radiol 2018; 41:762-771. [PMID: 29417266 DOI: 10.1007/s00270-018-1888-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Accepted: 01/22/2018] [Indexed: 10/18/2022]
Abstract
PURPOSE To compare, in an interventional radiology setting, peak skin doses (PSDs) delivered as calculated using a dedicated software tool and as measured using radiochromic film. To assess the utility of this dose calculation software tool in routine clinical practice. MATERIALS AND METHODS First, radiochromic films were positioned on the examination table in the back of an adult anthropomorphic phantom to measure PSD, and X-ray examinations were simulated. Then, films were again positioned in the patient's back for 59 thoracic or abdominopelvic endovascular interventions. The results obtained with the radiochromic films were taken as a reference and were statistically compared with those of the software. RESULTS With measured PSDs ranging from 100 to 7000 mGy, the median software-film difference was 8.5%. Lin's concordance coefficient was 0.98 [0.97; 0.99] (p < 0.001), meaning that concordance was excellent between the two methods. For the films where PSD exceeded 1000 mGy, the median difference in the measured value was 8.7% [- 1.3; 21.1], with a maximum discrepancy of 34%. Lin's concordance coefficient was 0.98 [0.96; 1] (p < 0.001), meaning that concordance was excellent between the two methods. CONCLUSION Comparison between radiochromic films and the software tool showed that the software is a suitable tool for a simple and reliable estimation of PSD. The software seems to be a good alternative to films, whose use remains complex.
Collapse
|
27
|
|
28
|
Assessment of peak skin dose in interventional cardiology: A comparison between Gafchromic film and dosimetric software em.dose. Phys Med 2017; 38:16-22. [DOI: 10.1016/j.ejmp.2017.05.044] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/12/2017] [Revised: 04/08/2017] [Accepted: 05/02/2017] [Indexed: 11/19/2022] Open
|
29
|
Assessment of Patient's Peak Skin Dose Using Gafchromic Films During Interventional Cardiology Procedures: Routine Experience Feedback. RADIATION PROTECTION DOSIMETRY 2017; 174:395-405. [PMID: 27522056 DOI: 10.1093/rpd/ncw191] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2016] [Accepted: 04/22/2016] [Indexed: 06/06/2023]
Abstract
To assess the interest of Gafchromic films in detection of patient's peak skin dose (PSD) in interventional cardiology. A prospective study of 112 patients was conducted (July-December 2015). Three diagnostic and therapeutic procedures were evaluated: coronary angiography (CA), coronary angiography and coronary angioplasty for one or two vessels disease (CA-PTCA) and coronary angioplasty of complex chronic total occlusion (CTO). Dosimetric indicators (DIs) were collected and PSD were measured with Gafchromic films. Dose distribution was evaluated within 10 'Thorax Body-zone' defined by the system. Correlations between PSD and DI or dose distribution were computed. Delivered dose increased in complex procedures. The PSD were 0.121 ± 0.063 Gy for CA, 0.256 ± 0.142 Gy for CA-PTCA and 1.116 ± 0.721 Gy for CTO. High correlations were observed for PSD and DI as well for dose distribution within the 'Thorax Body-zone'. Film dosimetry is suggested for CTO procedures since the threshold of 2 Gy for skin injuries is likely to be exceeded.
Collapse
|
30
|
Unintended and accidental medical radiation exposures in radiology: guidelines on investigation and prevention. JOURNAL OF RADIOLOGICAL PROTECTION : OFFICIAL JOURNAL OF THE SOCIETY FOR RADIOLOGICAL PROTECTION 2017; 37:883-906. [PMID: 28836506 DOI: 10.1088/1361-6498/aa881e] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This paper sets out guidelines for managing radiation exposure incidents involving patients in diagnostic and interventional radiology. The work is based on collation of experiences from representatives of international and national organizations for radiologists, medical physicists, radiographers, regulators, and equipment manufacturers, derived from an International Atomic Energy Agency Technical Meeting. More serious overexposures can result in skin doses high enough to produce tissue reactions, in interventional procedures and computed tomography, most notably from perfusion studies. A major factor involved has been deficiencies in training of staff in operation of equipment and optimization techniques. The use of checklists and time outs before procedures commence, and dose alerts when critical levels are reached during procedures, can provide safeguards to reduce the risks of these effects occurring. However, unintended and accidental overexposures resulting in relatively small additional doses can take place in any diagnostic or interventional x-ray procedure and it is important to learn from errors that occur, as these may lead to increased risks of stochastic effects. Such events may involve the wrong examinations, procedural errors, or equipment faults. Guidance is given on prevention, investigation, and dose calculation for radiology exposure incidents within healthcare facilities. Responsibilities should be clearly set out in formal policies, and procedures should be in place to ensure that root causes are identified and deficiencies addressed. When an overexposure of a patient or an unintended exposure of a foetus occurs, the foetal, organ, skin, and/or effective dose may be estimated from exposure data. When doses are very low, generic values for the examination may be sufficient, but a full assessment of doses to all exposed organs and tissues may sometimes be required. The use of general terminology to describe risks from stochastic effects is recommended rather than the calculation of numerical values, as these are misleading when applied to individuals.
Collapse
|
31
|
A method to reduce patient's eye lens dose in neuro-interventional radiology procedures. Radiat Phys Chem Oxf Engl 1993 2016. [DOI: 10.1016/j.radphyschem.2016.03.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
32
|
VERIFICATION OF INDICATED SKIN ENTRANCE AIR KERMA FOR CARDIAC X-RAY-GUIDED INTERVENTION USING GAFCHROMIC FILM. RADIATION PROTECTION DOSIMETRY 2016; 169:245-248. [PMID: 26541185 DOI: 10.1093/rpd/ncv460] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
The aim of this work was to verify the indicated maximum entrance surface air kerma (ESAK) using a GE Innova IGS 520 imaging system during cardiac interventional procedures. Gafchromic XR RV3 films were used for the patient measurements to monitor the maximum ESAK. The films were scanned and calibrated to measure maximum ESAK. Thermoluminescent dosemeters were used to measure the backscatter factor from an anthropomorphic thorax phantom. The measured backscatter factor, 1.53, was in good agreement with Monte Carlo simulations but higher than the one used by the imaging system, 1.20. The median of the ratio between indicated maximum ESAK and measured maximum ESAK was 0.68. In this work, the indicated maximum ESAK by the imaging system's dose map model underestimates the measured maximum ESAK by 32 %. The threshold ESAK for follow-up procedures for patient with skin dose in excess of 2 Gy will be reduced to 1.4 Gy.
Collapse
|
33
|
Characterisation of grids of point detectors in maximum skin dose measurement in fluoroscopically-guided interventional procedures. Phys Med 2015; 31:1112-1117. [DOI: 10.1016/j.ejmp.2015.08.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/29/2015] [Revised: 08/26/2015] [Accepted: 08/28/2015] [Indexed: 10/22/2022] Open
|
34
|
Assessment of Local Dose Reference Values for Recanalization of Chronic Total Occlusions and Other Occlusions in a High-Volume Catheterization Center. Am J Cardiol 2015; 116:1179-84. [PMID: 26275581 DOI: 10.1016/j.amjcard.2015.07.026] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/26/2015] [Revised: 07/16/2015] [Accepted: 07/16/2015] [Indexed: 11/22/2022]
Abstract
The increasing number and complexity of these procedures have led to a higher number of patients at risk for tissue reactions like skin injuries. Monitoring of their dose indicators is essential in recognizing these patients. The aim of this work was to determine local diagnostic reference levels (DRLs) for recanalization of chronic total occlusion (CTO) and other occlusions procedures. All data from patients who underwent cardiac procedures were reviewed and classified according to their complexity. Dose indicators such as fluoroscopy time (FT), dose area product (DAP), and air kerma at patient entrance reference point (AKr) were recorded. Correlations with patient's body mass index, operators, procedure strategy, and complexity were studied. For CTO, the mean DAP, AKr, and FT were 252 ± 234 Gycm(2), 3,985 ± 3,579 mGy, and 47 ± 36 minutes, respectively. To better reflect the non-Gaussian distribution of data, the median and the 75th percentile values were also reported: median DAP, 172 Gycm(2); 75th percentile DAP, 350 Gycm(2); median AKr, 2,714 mGy; and 75th percentile AKr, 5,921 mGy. A tentative new set of values were suggested to take into account the complexity difference in recanalization of total occlusions according to their antegrade or retrograde approach. These approach-specific DRLs for total occlusions were mean DAP (120 ± 114 Gycm(2)), mean AKr (1,789 ± 1,933 mGy), and mean FT (22 ± 18 minutes) for antegrade approach and mean DAP (459 ± 304 Gycm(2)), mean AKr (6,881 ± 4,243 mGy), and mean FT (82 ± 40 minutes) for retrograde approach. The other significant values were median DAP (84 Gycm(2)), 75th percentile DAP (147 Gycm(2)), median AKr (1,160 mGy), and 75th percentile AKr (2,176 mGy) for antegrade approach and median DAP (422 Gycm(2)), 75th percentile DAP (552 Gycm(2)), median AKr (6,295 mGy), and 75th percentile AKr (8,064 mGy) for retrograde approach. In conclusion, a set of local DRL values from a large center were assessed. DRLs were provided for antegrade and retrograde approaches, reflecting the difference in difficulty from these 2 kinds of CTOs. The wide dose estimator values variations were explained through procedure complexity. The values obtained for the other more classic percutaneous coronary interventions were comparable with those found in the literature.
Collapse
|
35
|
Accuracy of a dose map method assessed in clinical and anthropomorphic phantom situations using Gafchromic films. RADIATION PROTECTION DOSIMETRY 2015; 165:244-249. [PMID: 25802467 DOI: 10.1093/rpd/ncv034] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
A dose map method has been integrated on GE x-ray angiographic systems to provide an indication of the local dose distributed on a patient envelope representative of individual patient shapes. Tests have been performed to assess the accuracy of the method by using Gafchromic XR-RV3 films in an anthropomorphic phantom situation and in a clinical situation. Dose values inside different exposed areas have been compared between the film and the dose map method. The dose map results show a good visual agreement for the anthropomorphic phantom situation, and the local doses agreed within better than 15 % compared with the Gafchromic films in both situations.
Collapse
|
36
|
Editor's Choice – Minimizing Radiation Exposure During Endovascular Procedures: Basic Knowledge, Literature Review, and Reporting Standards. Eur J Vasc Endovasc Surg 2015; 50:21-36. [DOI: 10.1016/j.ejvs.2015.01.014] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2014] [Accepted: 01/27/2015] [Indexed: 12/30/2022]
|