1
|
Turuban M, Kromhout H, Vila J, de Vocht F, Vallbona-Vistós M, Baldi I, Cardis E, Turner MC. Comparison of a radiofrequency electric and magnetic field source-based job-exposure matrix with personal radiofrequency exposure measurements. Ann Work Expo Health 2024; 68:951-966. [PMID: 39326006 DOI: 10.1093/annweh/wxae072] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2024] [Accepted: 09/02/2024] [Indexed: 09/28/2024] Open
Abstract
OBJECTIVES Assessing occupational exposure to radiofrequency electromagnetic fields (RF-EMF) presents significant challenges due to the considerable variability in exposure levels within and between occupations. This spatial and temporal variability complicates the reliable evaluation of potential health risks associated with RF-EMF exposure in the workplace. Accurate assessment methods are crucial to understand the extent of exposure and to evaluate potential health risks, especially given the potential for higher exposures in occupational settings compared to the general population. This study compares the historical RF-EMF exposure estimates in the INTEROCC RF-EMF job-exposure matrix (RF-JEM) with recent personal measurement data collected in 2 countries as part of the OccRF-Health study, to assess the broader applicability of the RF-JEM. METHODS Weighted kappa (kw) coefficients and Spearman rank correlation tests were performed to assess the alignment between RF-JEM estimates and measurements for 8 h time-weighted average exposure intensity and prevalence estimates across various occupations. The comparisons were mainly based on 22 jobs having ≥5 measured workers in the OccRF-Health study. RESULTS Poor agreement was found for both exposure prevalence and intensity between both methods (kw < 0.1). RF-JEM values likely overestimated exposure levels for both electric (E) and magnetic (H) fields (mean percentage difference >194%) compared to current personal measurements. CONCLUSIONS Findings suggest that the INTEROCC-JEM likely overestimates current exposure intensity levels in the measured jobs. Adopting a semiquantitative JEM could also mitigate misclassification errors due to exposure variability, improving accuracy in exposure assessment. These findings indicate the need for more targeted personal measurements, including among highly exposed workers, and for potentially considering new exposure metrics to more accurately assess occupational RF-EMF exposures in occupational epidemiological research.
Collapse
Affiliation(s)
- Maxime Turuban
- Barcelona Institute for Global Health (ISGlobal), C/ del Rosselló, 132, L'Eixample, 08036, Barcelona, Spain
- Universitat Pompeu Fabra (UPF), Facultat de Medicina i Ciències de la Vida, C/ del Dr. Aiguader, 80, Ciutat Vella, 08003, Barcelona, Spain
| | - Hans Kromhout
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Yalelaan 2, 3584 CM, Utrecht, The Netherlands
| | - Javier Vila
- Environmental Protection Agency (EPA), Office of Radiation Protection and Environmental Monitoring, Johnstown Castle, Y35 W821, Wexford, Ireland
| | - Frank de Vocht
- Population Health Sciences, Bristol Medical School, University of Bristol, Canynge Hall, 39 Whatley Road, BS8 2PS, Bristol, United Kingdom
- NIHR Applied Research Collaboration West (NIHR ARC West), Bristol, United Kingdom
| | - Miquel Vallbona-Vistós
- Barcelona Institute for Global Health (ISGlobal), C/ del Rosselló, 132, L'Eixample, 08036, Barcelona, Spain
| | - Isabelle Baldi
- INSERM UMR 1219 Epicene Team, Bordeaux Population Health Research Center, 146 Rue Léo Saignat, 33076, Bordeaux, France
- Service Santé Travail Environnement, CHU de Bordeaux, 33000, Bordeaux, France
| | - Elisabeth Cardis
- Barcelona Institute for Global Health (ISGlobal), C/ del Rosselló, 132, L'Eixample, 08036, Barcelona, Spain
- Universitat Pompeu Fabra (UPF), Facultat de Medicina i Ciències de la Vida, C/ del Dr. Aiguader, 80, Ciutat Vella, 08003, Barcelona, Spain
- Spanish Consortium for Research and Public Health (CIBERESP), Instituto de Salud Carlos III, 28029, Madrid, Spain
| | - Michelle C Turner
- Barcelona Institute for Global Health (ISGlobal), C/ del Rosselló, 132, L'Eixample, 08036, Barcelona, Spain
- Universitat Pompeu Fabra (UPF), Facultat de Medicina i Ciències de la Vida, C/ del Dr. Aiguader, 80, Ciutat Vella, 08003, Barcelona, Spain
- Spanish Consortium for Research and Public Health (CIBERESP), Instituto de Salud Carlos III, 28029, Madrid, Spain
| |
Collapse
|
2
|
Turuban M, Kromhout H, Vila J, Vallbona-Vistós M, Baldi I, Turner MC. Personal exposure to radiofrequency electromagnetic fields in various occupations in Spain and France. ENVIRONMENT INTERNATIONAL 2023; 180:108156. [PMID: 37722304 DOI: 10.1016/j.envint.2023.108156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2023] [Revised: 08/15/2023] [Accepted: 08/16/2023] [Indexed: 09/20/2023]
Abstract
BACKGROUND A preliminary job-exposure matrix (JEM) for radiofrequency electromagnetic fields (RF-EMF) was created based on self-reported occupational information from a multi-country population-based study of approximately 10,000 participants combined with available measurement data compiled in a source-exposure matrix (spot measurements). In order to address the limited personal occupational RF-EMF measurement data available in the literature, we performed a measurement campaign among workers in various occupations in Spain and France. METHODS Personal full-shift measurements were conducted using RadMan 2XT™ (Narda) devices. A worker diary was used to capture information on occupational and background sources of RF exposure during the shift. Inclusion of occupations to be measured was initially based on exposure prevalence and level information in the preliminary JEM and expert judgment. RESULTS Personal full-shift measurements were conducted among 333 workers representing 46 ISCO88 occupations. Exposure to electric (E) and magnetic (H) fields was infrequent with >99% of measurements below the detection limit of the device (≥1% of the 1998 ICNIRP standards). A total of 50.2% and 77.2% of workers were ever exposed to E and H fields respectively (having at least one recorded 1-second measurement above the detection limit). Workers in elementary occupations, technicians and associate professionals, plant and machine operators and assemblers had somewhat greater numbers of measurements above the detection limit, higher maximum values and longer exposure durations. A small proportion of measurements were ≥100% of the standards, though these exceedances were brief (generally a few seconds in duration). Female workers and workers reporting use of any RF-EMF emitting source were more likely to have a measured exposure to E and H fields. CONCLUSION We conducted personal RF-EMF measurements among workers in various occupations in Spain and France. Overall, RF-EMF exposure ≥1 % ICNIRP was infrequent, despite some intermittent exposures ≥100% observed among workers in some occupations.
Collapse
Affiliation(s)
- Maxime Turuban
- Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain
| | - Hans Kromhout
- Institute for Risk Assessment Sciences (IRAS), Utrecht University, Utrecht, The Netherlands
| | - Javier Vila
- Environmental Protection Agency (EPA), Office of Radiation Protection and Environmental Monitoring, Wexford, Ireland
| | | | - Isabelle Baldi
- INSERM UMR 1219 Epicene Team, Bordeaux Population Health Research Center, Bordeaux, France; Service Santé Travail Environnement, CHU de Bordeaux, Bordeaux, France
| | - Michelle C Turner
- Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain; Universitat Pompeu Fabra (UPF), Barcelona, Spain; CIBER Epidemiología y Salud Pública (CIBERESP), Madrid, Spain.
| |
Collapse
|
3
|
Occupational Exposure Assessment of the Static Magnetic Field Generated by Nuclear Magnetic Resonance Spectroscopy: A Case Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19137674. [PMID: 35805332 PMCID: PMC9265854 DOI: 10.3390/ijerph19137674] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Revised: 06/09/2022] [Accepted: 06/21/2022] [Indexed: 01/27/2023]
Abstract
Magnetic resonance (MR) systems are used in academic research laboratories and industrial research fields, besides representing one of the most important imaging modalities in clinical radiology. This technology does not use ionizing radiation, but it cannot be considered without risks. These risks are associated with the working principle of the technique, which mainly involves static magnetic fields that continuously increase—namely, the radiofrequency (RF) field and spatial magnetic field gradient. To prevent electromagnetic hazards, the EU and ICNIRP have defined workers’ exposure limits. Several studies that assess health risks for workers and patients of diagnostic MR are reported in the literature, but data on workers’ risk evaluation using nuclear MR (NMR) spectroscopy are very poor. Therefore, the aim of this research is the risk assessment of an NMR environment, paying particular attention to workers with active implantable medical devices (AIMDs). Our perspective study consisted of the measurement of the static magnetic field around a 300 MHz (7 T) NMR research spectrometer and the computation of the electric field induced by the movements of an operator. None of the calculated exposure parameters exceeded the threshold limits imposed by legislation for protection against short-term effects of acute occupational exposure, but our results revealed that the level of exposure exceeded the action level threshold limit for workers with AIMD during the execution of tasks requiring the closest proximity to the spectrometer. Moreover, the strong dependence of the induced electric field results from the walking speed models is shown. This case study represents a snapshot of the NMR risk assessment with the specific goal to increase the interest in the safety of NMR environments.
Collapse
|