Wilson-Stewart KS, Fontanarosa D, Malacova E, Trapp JV. Fluoroscopically guided vascular and cardiac transcatheter procedures: a comparison of occupational and patient dose by anatomical region. Phys Eng Sci Med 2023; 46:353-365. [PMID: 36877360 PMCID: PMC10030543 DOI: 10.1007/s13246-023-01226-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/15/2022] [Accepted: 01/27/2023] [Indexed: 03/07/2023]
Abstract
X-ray guided procedures are being performed by an increasing variety of medical specialties. Due to improvements in vascular transcatheter therapies, there is an increasing overlap of imaged anatomy between medical specialties. There is concern that non-radiology fluoroscopic operators may not have sufficient training to be well informed of the potential implications of radiation exposure and mitigation strategies to reduce dose. This was a prospective, observational, single center study to compare occupational and patient dose levels when imaging different anatomical regions during fluoroscopically guided cardiac and endovascular procedures. Occupational radiation dose was measured at the level of the temple of 24 cardiologists and 3 vascular surgeons (n = 1369), 32 scrub nurses (n = 1307) and 35 circulating nurses (n = 885). The patient dose was recorded for procedures (n = 1792) performed in three angiography suites. Abdominal imaging during endovascular aneurysm repair (EVAR) procedures was associated with a comparatively high average patient, operator and scrub nurse dose despite additional table-mounted lead shields. Air kerma was relatively high for procedures performed in the chest, and chest + pelvis. Higher dose area product and staff eye dose were recorded during procedures of the chest + pelvis due to the use of digital subtraction angiography to evaluate access route prior to/during transaortic valve implantation. Scrub nurses were exposed to higher average radiation levels than the operator during some procedures. Staff should be cognizant of the potentially higher radiation burden to patients and exposed personnel during EVAR procedures and cardiac procedures using digital subtraction angiography.
Collapse
Affiliation(s)
- Kelly S Wilson-Stewart
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia.
- Cardiovascular Suites, Greenslopes Private Hospital, Ramsay Health Care, Newdegate Street, Greenslopes, Brisbane, QLD, 4120, Australia.
- Centre for Biomedical Technologies (CBT), Queensland University of Technology, 149 Victoria Park Road, Kelvin Grove, Brisbane, QLD, 4059, Australia.
| | - Davide Fontanarosa
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia
- Centre for Biomedical Technologies (CBT), Queensland University of Technology, 149 Victoria Park Road, Kelvin Grove, Brisbane, QLD, 4059, Australia
| | - Eva Malacova
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia
- QIMR Berghofer Medical Research Institute, 300 Herston Road, Herston, QLD, 4006, Australia
| | - Jamie V Trapp
- School of Chemistry and Physics, Faculty of Science, Queensland University of Technology, 2 George Street, Brisbane, QLD, 4000, Australia
- Centre for Biomedical Technologies (CBT), Queensland University of Technology, 149 Victoria Park Road, Kelvin Grove, Brisbane, QLD, 4059, Australia
| |
Collapse
|
2
|
Wilson-Stewart KS, Fontanarosa D, Malacova E, Trapp JV. Radiation dose to nurses, cardiologists, and patients during coronary angiography: a comparison of femoral and radial access. Eur J Cardiovasc Nurs 2021; 21:325-331. [PMID: 34718509 DOI: 10.1093/eurjcn/zvab096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 08/26/2021] [Accepted: 10/03/2021] [Indexed: 11/13/2022]
Abstract
BACKGROUND Exposure to radiation during fluoroscopically guided cardiac procedures is a cause for concern for both the patient and staff. AIMS This study sought to compare the occupational and patient radiation dose during femoral and radially accessed invasive coronary angiography (CA). METHODS AND RESULTS Occupational dose (µSv) was measured at the left temple of the cardiologist (n = 17), scrub (n = 27), and circulator nurse (n = 27) during 761 femoral and 671 radially accessed diagnostic coronary angiograms and percutaneous coronary intervention (PCI) procedures. Patient dose parameters of dose area product (DAP) (Gy.cm2) and air kerma (AK) (Gy) were also measured. Coronary angiography performed via the radial artery is associated with greater mean dose to the cardiologist, with the exception of procedures including only PCI. Results demonstrated that scrub nurses are exposed to higher mean doses than the cardiologist when using femoral access and similar doses during radial cases. Both AK and DAP were associated with a higher average dose for femoral PCI than radial, with DAP being significantly higher. CONCLUSIONS Awareness of factors that increase the dose to staff and patients is vital to inform and improve practice. This study has demonstrated that access route during diagnostic CA and PCI influences both patient and staff dose. Radiation dose to in-room staff other than the fluoroscopic operator should be a focus of future research. In addition, all staff present during X-ray guided procedures should be provided with radiation education and adopt dose minimization strategies to reduce occupational exposures.
Collapse
Affiliation(s)
- Kelly S Wilson-Stewart
- School of Chemistry and Physics, Faulty of Science and Engineering, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia.,Greenslopes Private Hospital, Ramsay Health Care, Newdegate Street, Greenslopes, Brisbane, QLD 4120 Australia
| | - Davide Fontanarosa
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia.,Centre for Biomedical Technologies (CBT), Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia
| | - Eva Malacova
- School of Clinical Sciences, Faculty of Health, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia.,QMIR Berghofer Medical Research Institute, 200 Herston Road, Herston, QLD 4006 Australia
| | - Jamie V Trapp
- School of Chemistry and Physics, Faulty of Science and Engineering, Queensland University of Technology, 2 George Street, Brisbane, QLD 4000 Australia
| |
Collapse
|
3
|
Betti M, Mazzoni LN, Belli G, Bernardi L, Bicchi S, Busoni S, Fedele D, Fedeli L, Gasperi C, Gori C, Quattrocchi M, Taddeucci A, Vigliotti M, Vaiano A, Rossi F. Surgeon eye lens dose monitoring in catheterization lab: A multi-center survey: Invited for ECMP 2018 Focus Issue. Phys Med 2019; 60:127-131. [PMID: 31000072 DOI: 10.1016/j.ejmp.2019.03.027] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/03/2018] [Revised: 03/27/2019] [Accepted: 03/27/2019] [Indexed: 01/04/2023] Open
Abstract
PURPOSE To perform a multi-centre survey on the eye lens equivalent dose absorbed by primary interventionalist during catheterization procedures, using a personal dosimeter placed close to the eye lens. METHODS 15 different cardiologists working in 3 different centers, for a total of 5 operating rooms were enrolled. All of them were provided with a single thermoluminescent dosimeter positioned on the inner side of the temples of eyeglasses. The dose monitoring, performed on a two-months basis, started in 2016 and is still running. All dose measurements were performed by a ISO 17025 standard accredited dosimetry service thus providing certified uncertainties as well. Correlation of eye lens and wrist dose with KAP was also investigated. RESULTS A total number of 101 eye lens measurements were performed. Annual eye lens dose estimation was obtained for all 15 surgeons (mean, mode, range, standard deviation: 10.8, 8, 4.9-27.3, 5.6 mSv, respectively). Uncertainties on annual eye lens dose estimations ranged between 10% and 20%. No significant correlation was found between eye lens dose and KAP. CONCLUSIONS Cardiologists involved in catheterization procedures may receive annual eye lens doses close to the ICRP 118 dose limit and thus individual monitoring with a dedicated dosimeter should be carried out. Uncertainty assessment play a relevant role in eye lens equivalent dose estimation to ensure not to exceed dose limit.
Collapse
Affiliation(s)
- Margherita Betti
- Azienda Usl Toscana Centro, Medical Physics Unit Pistoia Prato, Italy
| | | | - Giacomo Belli
- Azienda Ospedaliero-Universitaria Careggi, Medical Physics Unit, Firenze, Italy
| | - Luca Bernardi
- Azienda Usl Toscana Centro, Medical Physics Unit Pistoia Prato, Italy
| | - Sara Bicchi
- Azienda Usl Toscana Centro, Medical Physics Unit Pistoia Prato, Italy
| | - Simone Busoni
- Azienda Ospedaliero-Universitaria Careggi, Medical Physics Unit, Firenze, Italy
| | - David Fedele
- Azienda Usl Toscana Centro, Medical Physics Unit Pistoia Prato, Italy
| | - Luca Fedeli
- Università degli Studi di Firenze, Dipartimento di Fisica e Astronomia, Sesto Fiorentino, Firenze, Italy
| | - Chiara Gasperi
- Azienda Usl Toscana Sud-Est, Medical Physics Unit, Arezzo, Italy
| | - Cesare Gori
- Università degli Studi di Firenze, Dipartimento di Fisica e Astronomia, Sesto Fiorentino, Firenze, Italy; INFN, Sezione di Firenze, Sesto Fiorentino, Italy
| | | | - Adriana Taddeucci
- Azienda Ospedaliero-Universitaria Careggi, Medical Physics Unit, Firenze, Italy
| | | | - Angela Vaiano
- Azienda Usl Toscana Centro, Medical Physics Unit Pistoia Prato, Italy
| | - Francesco Rossi
- Azienda Ospedaliero-Universitaria Careggi, Medical Physics Unit, Firenze, Italy
| |
Collapse
|