Yu J, Xiao Z, Yu R, Liu X, Chen H. Diagnostic Value of Hounsfield Units for Osteoporotic Thoracolumbar Vertebral Non-Compression Fractures in Elderly Patients with Low-Energy Injuries. Int J Gen Med 2024; 17:3221-3229. [PMID: 39070224 PMCID: PMC11283241 DOI: 10.2147/ijgm.s471770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2024] [Accepted: 07/17/2024] [Indexed: 07/30/2024] Open
Abstract
Background Thoracolumbar vertebral fractures are common pathological fractures caused by osteoporosis in the elderly. These fractures are challenging to detect. This study aimed to evaluate the diagnostic value of Hounsfield units for osteoporotic thoracolumbar vertebral non-compression fractures in elderly patients with low-energy fractures. Methods The retrospective case-control study included elderly patients diagnosed with osteoporotic thoracolumbar vertebral fractures and non-fractured patients who underwent computed tomography examinations for lumbar vertebra issues during July 2017 and June 2020. Results This study included 216 patients with fractures (38 males and 178 females; average age: 77.28±8.68 years) and 124 patients without fractures (21 males and 103 females; average age: 75.35±9.57 years). The difference in Hounsfield units of the target (intermediate) vertebral body significantly differed between the two groups (54.74 ± 21.84 vs 5.86 ± 5.14; p<0.001). The ratios of Hounsfield units were also significantly different between the two groups (1.38 ± 1.60 vs 0.13 ± 0.23; p<0.001). The cut-off value for the difference in Hounsfield units to detect osteoporotic spine fractures was 25.35, with high sensitivity (98.5%), specificity (99.9%), and the area under the curve (AUC) (0.999, 95% CI: 0.999-1). The cut-off value for the odds ratio of Hounsfield units was 0.260, with high sensitivity (99.1%), specificity (92.7%), and AUC (0.970, 95% CI: 0.949-0.992). Conclusion The difference between Hounsfield units and the odds ratio of Hounsfield units might help diagnose osteoporotic thoracolumbar vertebral non-compression fractures in elderly patients with low-energy fractures.
Collapse
Affiliation(s)
- Jiangming Yu
- Department of Orthopedics, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Zhengguang Xiao
- Department of Radiology, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Ronghua Yu
- Department of Orthopedics, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Xiaoming Liu
- Department of Orthopedics, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| | - Haojie Chen
- Department of Orthopedics, Tongren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People’s Republic of China
| |
Collapse
|
2
|
Lāce E, Mohammadian R, Āboltiņš A, Sosārs D, Apine I. Trade-off between the radiation parameters and image quality using iterative reconstruction techniques in head computed tomography: a phantom study. Acta Radiol 2023; 64:2618-2626. [PMID: 37469141 DOI: 10.1177/02841851231185347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/21/2023]
Abstract
BACKGROUND Iterative reconstruction techniques (IRTs) are commonly used in computed tomography (CT) and help to reduce image noise. PURPOSE To determine the minimum radiation dose while preserving image quality in head CT using IRTs. MATERIAL AND METHODS The anthropomorphic phantom was used to scan nine head CT image series with varied radiation parameters. CT dose parameters, including volume CT dose index (CTDIvol [in mGy]) and dose length product (DLP [in mGy/cm]), were recorded for each scan series. Different noise levels (iDoseL1-6) were used in IRT reconstructions for soft and bone tissues. In total, 15 measurements were taken from five regions of interest (ROI) with an area of 10 mm2. The signal-to-noise ratio (SNR) and noise values obtained at different ROIs were compared among various reconstruction methods with repeated measures of statistical analysis. RESULTS In the head CT scan, applying IRT iDoseL5 had the lowest noise and highest SNR for soft tissue (P < 0.05), and increased iDose can decrease CT dose by 54.6% without compromising image quality. While for bone tissue reconstruction, no clear association was found between the level of iDose and noise. However, when CTDIvol is >20 mGy, iDoseL4 is slightly superior to other reconstruction methods (P < 0.065). CONCLUSION Using IRTs in head CTs reduces radiation dose while maintaining image quality. IDoseL5 provided optimal balance for soft tissue.
Collapse
Affiliation(s)
- Elīza Lāce
- Department of Radiology, Riga Stradin's University, Riga, Latvia
| | - Reza Mohammadian
- Department of Radiology, Riga Stradin's University, Riga, Latvia
| | - Ainārs Āboltiņš
- Department of Radiology, Children's Clinical University Hospital, Riga, Latvia
| | - Dāvis Sosārs
- Department of Radiology, Children's Clinical University Hospital, Riga, Latvia
| | - Ilze Apine
- Department of Radiology, Riga Stradin's University, Riga, Latvia
- Department of Radiology, Children's Clinical University Hospital, Riga, Latvia
| |
Collapse
|
3
|
Mehnati P, Malekzadeh R, Hussein HA, Obaid NH, Ebrahimiyan S, Sooteh MY, Refahi S. Trade-off between breast dose and image quality using composite bismuth shields in computed tomography: A phantom study. J Med Imaging Radiat Sci 2023; 54:145-152. [PMID: 36646544 DOI: 10.1016/j.jmir.2022.12.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2022] [Revised: 10/26/2022] [Accepted: 12/07/2022] [Indexed: 01/15/2023]
Abstract
INTRODUCTION Many researchers have suggested that bismuth composite shields (BCS) reduce breast dose remarkably; however, the level of this reduction and its impact on image quality has not been assessed. This study aimed to evaluate the efficiency of nano- and micro- BCS in reducing the dose and image quality during chest computed tomography (CT) scans. MATERIALS AND METHODS Bismuth shields composed of 15 weighting percentage (wt%) and 20 wt% bismuth oxide (Bi2O3) nano- and micro-particles mixed in silicon rubber polymer were constructed in 1 and 1.5 mm thicknesses. The physical properties of nanoparticles were assessed using a scanning electron microscope (SEM), X-ray diffraction (XRD), and energy-dispersive X-ray (EDX). Breast radiation doses were measured experimentally during chest CT using PMMA standard dosimetry phantom (body phantom, 76-419-4150, Fluke Biomedical) in the presence of the shields. The image quality was assessed by calculating signal and noise values in different regions. RESULTS The SEM images showed that the average size of Bi2O3 nano- and micro-particles was about 70 nm and 150 μm, respectively. The breast doses were reduced by increasing the shield thickness/bismuth weight percentage. The maximum dose reduction was related to the 20% weight of Bi2O3 nano-particles and a thickness of 1.5 mm. The minimum dose reduction was related to the 15% weight of Bi2O3 micro-particles with a thickness of 1 mm. The mean noise was higher in nano-particle bismuth shields than in micro-particles. CONCLUSION Composite shields containing bismuth nano- and micro-particles can reduce the breast dose during chest CT examinations while negatively impacting diagnostic image quality. Several critical factors, such as bismuth concentration, particle size, and shield thickness, directly affect the efficiency.
Collapse
Affiliation(s)
- Parinaz Mehnati
- Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Reza Malekzadeh
- Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Noor H Obaid
- Anesthesia Techniques Department, Al-Mustaqbal University College, Babylon, Iraq
| | - Saadat Ebrahimiyan
- Department of Medical Physics and Radiology, School of Medicine, Gonabad University of Medical Sciences, Gonabad, Iran
| | - Mohammad Yousefi Sooteh
- Department of Medical Physics, School of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Soheila Refahi
- Department of Medical Physics, School of Medicine, Ardabil University of Medical Sciences, Ardabil, Iran.
| |
Collapse
|
4
|
Zamani H, Kavousi N, Masjedi H, Omidi R, Rahbar S, Perota G, Razavi E, Zare MH, Abedi-Firouzjah R. ESTIMATION OF DIAGNOSTIC REFERENCE LEVELS AND ACHIEVABLE DOSES FOR PEDIATRIC PATIENTS IN COMMON COMPUTED TOMOGRAPHY EXAMINATIONS: A MULTI-CENTER STUDY. RADIATION PROTECTION DOSIMETRY 2021; 194:214-222. [PMID: 34244802 DOI: 10.1093/rpd/ncab093] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Revised: 05/06/2021] [Accepted: 06/02/2021] [Indexed: 06/13/2023]
Abstract
This study was conducted to determine first local diagnostic reference levels (DRLs) and achievable doses (ADs) for pediatric patients during the most common computed tomography (CT) procedures in Yazd province. The DRL was obtained based on volume CT dose index (CTDIvol) and dose length product (DLP) for four various age groups of children. Data were collected from the most commonly performed pediatric CT scans, including abdomen-pelvis, chest, brain and sinus examinations, at six high-loaded institutes. The patients' data (766 no.) in terms of CTDIvol and DLP were obtained from four age groups: ≤1-, 1-5-, 5-10- and 10-15-y-old. The 75th percentiles of CTDIvol and DLP were considered as DRL values and the 50th percentiles were described as ADs for those parameters. Consequently, the acquired DRLs were compared with other national and international published values. The DRLs in terms of CTDIvol for abdomen-pelvis, chest, brain and sinus examinations were 3, 8, 9 and 10 mGy; 4, 5, 5 and 5 mGy; 25, 28, 29 and 38 mGy; and 23, 24, 26 and 27 mGy for four different age groups of ≤1-, 1-5-, 5-10- and 10-15-y-old, respectively. The DRL values in terms of DLP were 75, 302, 321 and 342 mGy.cm; 109, 112, 135 and 170 mGy.cm, 352, 355, 360 and 481 mGy.cm; and 206, 211, 228 and 245 mGy.cm, respectively, for the mentioned age groups. In this study, the DRL and AD values in the brain examination were greater among the other studied regions. The DRL plays a critical role in the optimization of radiation doses delivered to patients and in improving their protection. This study provides the local DRLs and ADs for the most common pediatric CT scanning in Yazd province to create optimum situation for the clinical practice.
Collapse
Affiliation(s)
- Hamed Zamani
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran
| | - Nasim Kavousi
- Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Mashhad, Iran
| | - Hamidreza Masjedi
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran
| | - Reza Omidi
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran
| | - Shiva Rahbar
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran
| | - Ghazale Perota
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran
| | | | - Mohammad Hosein Zare
- Department of Medical Physics, Faculty of Medicine, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran
- Clinical Research Development Center of Shahid Sadoughi hospital, Shahid Sadoughi University of Medical Sciences, Yazd 8915173160, Iran
| | | |
Collapse
|
5
|
Kiapour M, Ebrahimnejad Gorji K, Mehraeen R, Ghaemian N, Niksirat Sustani F, Abedi-Firouzjah R, Shabestani Monfared A. Can Common Lead Apron in Testes Region Cause Radiation Dose Reduction during Chest CT Scan? A Patient Study. J Biomed Phys Eng 2021; 11:497-504. [PMID: 34458197 PMCID: PMC8385221 DOI: 10.31661/jbpe.v0i0.2104-1307] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 05/31/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND Computed tomography (CT) is a routine procedure for diagnosing using ionization radiation which has hazardous effects especially on sensitive organs. OBJECTIVE The aim of this study was to quantify the dose reduction effect of lead apron shielding on the testicular region during routine chest CT scans. MATERIAL AND METHODS In this measurement study, the routine chest CT examinations were performed for 30 male patients with common lead aprons folded and positioned in testis regions. The patient's mean body mass index (BMI) was 26.2 ± 4.6 kg/m2. To calculate the doses at testis region, three thermoluminescent dosimeters (TLD-100) were attached at the top surface of the apron as an indicator of the doses without shielding, and three TLDs under the apron for doses with shielding. The TLD readouts were compared using SPSS software (Wilcoxon test) version 16. RESULTS The radiation dose in the testicular regions was reduced from 0.46 ± 0.04 to 0.20 ± 0.04 mGy in the presence of lead apron shielding (p < 0.001), the reduction was equal to 56%. Furthermore, the heritable risk probability was obtained at 2.0 ×10-5 % and 4.6 ×10-5 % for the patients using the lead apron shield versus without shield, respectively. CONCLUSION Applying common lead aprons as shielding in the testis regions of male patients undergoing chest CT scans can reduce the radiation doses significantly. Therefore, this shield can be recommended for routine chest CT examinations.
Collapse
Affiliation(s)
- Mohammad Kiapour
- MSc, Student Research Committee, Babol University of Medical Sciences, Babol, Iran
| | - Kourosh Ebrahimnejad Gorji
- PhD, Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran
| | - Rahele Mehraeen
- MD, Department of Pediatric Radiology, Babol University of Medical Sciences, Babol, Iran
| | - Naser Ghaemian
- MD, Department of Radiology and Radiotherapy, School of Medicine, Babol University of Medical Sciences, Babol, Iran
| | - Fatemeh Niksirat Sustani
- MSc, Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran
| | - Razzagh Abedi-Firouzjah
- MSc, Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran
| | - Ali Shabestani Monfared
- PhD, Cancer Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran
| |
Collapse
|
6
|
Azadbakht J, Khoramian D, Lajevardi ZS, Elikaii F, Aflatoonian AH, Farhood B, Najafi M, Bagheri H. A review on chest CT scanning parameters implemented in COVID-19 patients: bringing low-dose CT protocols into play. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2021. [PMCID: PMC7784224 DOI: 10.1186/s43055-020-00400-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
Abstract
Background
This study aims to review chest computed tomography (CT) scanning parameters which are utilized to evaluate patients for COVID-19-induced pneumonia. Also, some of radiation dose reduction techniques in CT would be mentioned, because using these techniques or low-dose protocol can decrease the radiation burden on the population.
Main body
Chest CT scan can play a key diagnostic role in COVID-19 patients. Additionally, it can be useful to monitor imaging changes during treatment. However, CT scan overuse during the COVID-19 pandemic raises concerns about radiation-induced adverse effects, both in patients and healthcare workers.
Conclusion
By evaluating the CT scanning parameters used in several studies, one can find the necessity for optimizing these parameters. It has been found that chest CT scan taken using low-dose CT protocol is a reliable diagnostic tool to detect COVID-19 pneumonia in daily practice. Moreover, the low-dose chest CT protocol results in a remarkable reduction (up to 89%) in the radiation dose compared to the standard-dose protocol, not lowering diagnostic accuracy of COVID-19-induced pneumonia in CT images. Therefore, its employment in the era of the COVID-19 pandemic is highly recommended.
Collapse
|
7
|
Davoudi M, Lotfian Ahangarkolaei S. Image optimization and reduction of radiation dose in CT of the paranasal sinuses. Biomed Phys Eng Express 2020; 6:045021. [PMID: 33444281 DOI: 10.1088/2057-1976/ab9063] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
INTRODUCTION Due to use of ionization radiation in the computed tomography (CT), optimal parameters should be used to reduce the risk of incidence of secondary cancers in patients who are constantly exposed to x-rays. To reduce the dose delivered to patients in each scan, CT technologists can change the image acquisition parameters. However, this reduces image quality. The present study aimed to optimize and reduce radiation dose in a CT of the paranasal sinuses while minimizing deterioration of image quality. METHODS In this study patients were divided in two groups: Group A was scanned axially and coronally using default parameters, while Group B was scanned axially and coronally using new parameters. Common CT dose descriptors including weighted computed tomography dose index (CTDIw), volumetric CTDI (CTDIvol), dose length product (DLP), effective dose (ED) and image noise were measured for each group. The patients' organ doses were estimated using the ImPACT CT patient Dosimetry Calculator. The tube voltage, tube current, pitch, rotation time, and other parameters were then reduced and optimized. After reconstruction and analysis, all of the images were of good diagnostic quality in both groups Results: Using the new parameters, good agreement was found between the direct and reconstructed images. The CT parameters were reduced by the following proportions: kVp-16.6%, mA-75%, rotation time-20%, and mAs-80%. However, these reductions did not obscure any anatomical landmarks. These parameters reduced the CTDIw, CTDIvol and DLP by 88.2%, 91.3%, and 91.3% respectively. CONCLUSION The results suggest that the use of a Bone algorithm reduces the total amount of radiation used during CT of the sinuses. We recommend using these parameters in children, in the evaluation of facial trauma, and in emergency CT of the paranasal sinuses.
Collapse
Affiliation(s)
- Mohammad Davoudi
- Department of Medical Imaging Center, Babol University of Medical Sciences, Babol, Iran
| | | |