1
|
Sethia N, Rao JS, Khashim Z, Schornack AMR, Etheridge ML, Peterson QP, Finger EB, Bischof JC, Dutcher CS. On Chip Sorting of Stem Cell-Derived β Cell Clusters Using Traveling Surface Acoustic Waves. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2024; 40:3453-3462. [PMID: 38318799 PMCID: PMC10883307 DOI: 10.1021/acs.langmuir.3c02934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2023] [Revised: 12/05/2023] [Accepted: 01/04/2024] [Indexed: 02/07/2024]
Abstract
There is a critical need for sorting complex materials, such as pancreatic islets of Langerhans, exocrine acinar tissues, and embryoid bodies. These materials are cell clusters, which have highly heterogeneous physical properties (such as size, shape, morphology, and deformability). Selecting such materials on the basis of specific properties can improve clinical outcomes and help advance biomedical research. In this work, we focused on sorting one such complex material, human stem cell-derived β cell clusters (SC-β cell clusters), by size. For this purpose, we developed a microfluidic device in which an image detection system was coupled to an actuation mechanism based on traveling surface acoustic waves (TSAWs). SC-β cell clusters of varying size (∼100-500 μm in diameter) were passed through the sorting device. Inside the device, the size of each cluster was estimated from their bright-field images. After size identification, larger clusters, relative to the cutoff size for separation, were selectively actuated using TSAW pulses. As a result of this selective actuation, smaller and larger clusters exited the device from different outlets. At the current sample dilutions, the experimental sorting efficiency ranged between 78% and 90% for a separation cutoff size of 250 μm, yielding sorting throughputs of up to 0.2 SC-β cell clusters/s using our proof-of-concept design. The biocompatibility of this sorting technique was also established, as no difference in SC-β cell cluster viability due to TSAW pulse usage was found. We conclude the proof-of-concept sorting work by discussing a few ways to optimize sorting of SC-β cell clusters for potentially higher sorting efficiency and throughput. This sorting technique can potentially help in achieving a better distribution of islets for clinical islet transplantation (a potential cure for type 1 diabetes). Additionally, the use of this technique for sorting islets can help in characterizing islet biophysical properties by size and selecting suitable islets for improved islet cryopreservation.
Collapse
Affiliation(s)
- Nikhil Sethia
- Department
of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Joseph Sushil Rao
- Division
of Solid Organ Transplantation, Department of Surgery, University of Minnesota, Minneapolis, Minnesota 55455, United States
- Schulze
Diabetes Institute, Department of Surgery, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - Zenith Khashim
- Department
of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Anna Marie R. Schornack
- Department
of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Michael L. Etheridge
- Department
of Mechanical Engineering, University of
Minnesota, Minneapolis, Minnesota 55455, United States
| | - Quinn P. Peterson
- Department
of Physiology and Biomedical Engineering, Mayo Clinic, Rochester, Minnesota 55905, United States
- Center for
Regenerative Biotherapeutics, Mayo Clinic, Rochester, Minnesota 55905, United States
| | - Erik B. Finger
- Division
of Solid Organ Transplantation, Department of Surgery, University of Minnesota, Minneapolis, Minnesota 55455, United States
| | - John C. Bischof
- Department
of Mechanical Engineering, University of
Minnesota, Minneapolis, Minnesota 55455, United States
- Department
of Biomedical Engineering, University of
Minnesota, Minneapolis, Minnesota 55455, United States
| | - Cari S. Dutcher
- Department
of Chemical Engineering and Materials Science, University of Minnesota, Minneapolis, Minnesota 55455, United States
- Department
of Mechanical Engineering, University of
Minnesota, Minneapolis, Minnesota 55455, United States
| |
Collapse
|
2
|
Khan MS, Sahin MA, Destgeer G, Park J. Residue-free acoustofluidic manipulation of microparticles via removal of microchannel anechoic corner. ULTRASONICS SONOCHEMISTRY 2022; 89:106161. [PMID: 36088893 PMCID: PMC9464887 DOI: 10.1016/j.ultsonch.2022.106161] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/15/2022] [Revised: 08/18/2022] [Accepted: 09/03/2022] [Indexed: 06/15/2023]
Abstract
Surface acoustic wave (SAW)-based acoustofluidics has shown significant promise to manipulate micro/nanoscale objects for biomedical applications, e.g. cell separation, enrichment, and sorting. A majority of the acoustofluidic devices utilize microchannels with rectangular cross-section where the acoustic waves propagate in the direction perpendicular to the sample flow. A region with weak acoustic wave intensity, termed microchannel anechoic corner (MAC), is formed inside a rectangular microchannel of the acoustofluidic devices where the ultrasonic waves refract into the fluid at the Rayleigh angle with respect to the normal to the substrate. Due to the absence of a strong acoustic field within the MAC, the microparticles flowing adjacent to the microchannel wall remain unaffected by a direct SAW-induced acoustic radiation force (ARF). Moreover, an acoustic streaming flow (ASF) vortex produced within the MAC pulls the particles further into the corner and away from the direct ARF influence. Therefore, a residue of particles continues to flow past the SAWs without intended deflection, causing a decrease in microparticle manipulation efficiency. In this work, we introduce a cross-type acoustofluidic device composed of a half-circular microchannel, fabricated through a thermal reflow of a positive photoresist mold, to overcome the limitations associated with rectangular microchannels, prone to the MAC formation. We investigated the effects of different microchannel cross-sectional shapes with varying contact angles on the microparticle deflection in a continuous flow and found three distinct regimes of particle deflection. By systematically removing the MAC out of the microchannel cross-section, we achieved residue-free acoustofluidic microparticle manipulation via SAW-induced ARF inside a half-circular microchannel. The proposed method was applied to efficient fluorescent coating of the microparticles in a size-selective manner without any residue particles left undeflected in the MAC.
Collapse
Affiliation(s)
- Muhammad Soban Khan
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea
| | - Mehmet Akif Sahin
- Control and Manipulation of Microscale Living Objects, Central Institute for Translational Cancer Research (TranslaTUM), Department of Electrical and Computer Engineering, Technical University of Munich, Einsteinstraße 25, Munich 81675, Germany
| | - Ghulam Destgeer
- Control and Manipulation of Microscale Living Objects, Central Institute for Translational Cancer Research (TranslaTUM), Department of Electrical and Computer Engineering, Technical University of Munich, Einsteinstraße 25, Munich 81675, Germany.
| | - Jinsoo Park
- Department of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea.
| |
Collapse
|
3
|
Fan Y, Wang X, Ren J, Lin F, Wu J. Recent advances in acoustofluidic separation technology in biology. MICROSYSTEMS & NANOENGINEERING 2022; 8:94. [PMID: 36060525 PMCID: PMC9434534 DOI: 10.1038/s41378-022-00435-6] [Citation(s) in RCA: 22] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2022] [Revised: 06/14/2022] [Accepted: 07/19/2022] [Indexed: 05/30/2023]
Abstract
Acoustofluidic separation of cells and particles is an emerging technology that integrates acoustics and microfluidics. In the last decade, this technology has attracted significant attention due to its biocompatible, contactless, and label-free nature. It has been widely validated in the separation of cells and submicron bioparticles and shows great potential in different biological and biomedical applications. This review first introduces the theories and mechanisms of acoustofluidic separation. Then, various applications of this technology in the separation of biological particles such as cells, viruses, biomolecules, and exosomes are summarized. Finally, we discuss the challenges and future prospects of this field.
Collapse
Affiliation(s)
- Yanping Fan
- School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, 200093 China
| | - Xuan Wang
- School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai, 200093 China
- Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055 China
| | - Jiaqi Ren
- Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055 China
| | - Francis Lin
- Department of Physics and Astronomy, University of Manitoba, Winnipeg, MB R3T 2N2 Canada
| | - Jiandong Wu
- Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, 518055 China
| |
Collapse
|
4
|
Schnitzler LG, Paeger A, Brugger MS, Schneider MF, Westerhausen C. Reversible single cell trapping of Paramecium caudatum to correlate swimming behavior and membrane state. BIOMICROFLUIDICS 2022; 16:024102. [PMID: 35282034 PMCID: PMC8896893 DOI: 10.1063/5.0084084] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 02/15/2022] [Indexed: 06/14/2023]
Abstract
Single cell measurements with living specimen like, for example, the ciliated protozoan Paramecium caudatum can be a challenging task. We present here a microfluidic trapping mechanism for measurements with these micro-organisms that can be used, e.g., for optical measurements to correlate cellular functions with the phase state of the lipid membrane. Here, we reversibly trap single cells in small compartments. Furthermore, we track and analyze the swimming behavior of single cells over several minutes. Before and after reversible trapping the swimming speed is comparable, suggesting that trapping does not have a large effect on cell behavior. Last, we demonstrate the feasibility of membrane order measurements on living cells using the fluorescent dye 6-lauryl-2-dimethylaminonaphthalene (Laurdan).
Collapse
Affiliation(s)
| | - Anne Paeger
- Medical and Biological Physics, Technical University Dortmund, 44227 Dortmund, Germany
| | | | - Matthias F. Schneider
- Medical and Biological Physics, Technical University Dortmund, 44227 Dortmund, Germany
| | | |
Collapse
|
5
|
Afzal M, Park J, Jeon JS, Akmal M, Yoon TS, Sung HJ. Acoustofluidic Separation of Proteins Using Aptamer-Functionalized Microparticles. Anal Chem 2021; 93:8309-8317. [PMID: 34075739 DOI: 10.1021/acs.analchem.1c01198] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
We propose an acoustofluidic method for the triseparation of proteins conjugated with aptamer-coated microparticles inside a microchannel. Traveling surface acoustic waves (TSAWs) produced from a slanted-finger interdigital transducer (SFIT) are used to separate the protein-loaded microparticles of different sizes via the TSAW-driven acoustic radiation force (ARF). The acoustofluidic device consists of an SFIT deposited onto a piezoelectric lithium niobate substrate and a polydimethylsiloxane (PDMS) microfluidic channel on top of the substrate. The TSAWs propagating on the substrate penetrate into the sample fluid flow, where the human protein-conjugated microparticles are suspended, inside the PDMS microchannel. The microparticles are subjected to the TSAW-driven ARF with varying magnitude depending on their size and thus flow along different streamlines, leading to triseparation of the proteins. In this work, we used two different-sized streptavidin-functionalized polystyrene (PS) microparticles to capture two kinds of aptamers (apt15 and aptD17.4), which were labeled with a respective biotin molecule at one end. The biotin ends of the aptamers were attached to the microparticles through streptavidin-biotin linkage, whereas the free ends of the aptamers were used to capture their target proteins of thrombin (th) and immunoglobulin E (IgE). The resultant PS-apt15-th and PS-aptD17.4-IgE complexes, as well as mCardinal2, were used for experimental demonstration of acoustofluidic triseparation of the human proteins. We achieved simultaneous separation of proteins of three kinds (th, IgE, and mCardinal2) for the first time via the TSAW-driven ARF in the proposed acoustofluidic device.
Collapse
Affiliation(s)
- Muhammad Afzal
- Department of Mechanical Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Jinsoo Park
- School of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Korea
| | - Jessie S Jeon
- Department of Mechanical Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Muhammad Akmal
- Department of Materials Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Tae-Sung Yoon
- Department of Proteome Structural Biology, KRIBB, 125 Gwahak-ro, Yuseong-gu, Daejeon 34141, Korea
| | - Hyung Jin Sung
- Department of Mechanical Engineering, KAIST, 291 Daehak-ro, Yuseong-gu, Daejeon 34141, Korea
| |
Collapse
|