• Reference Citation Analysis
  • v
  • v
  • Find an Article
For: Solen KA, Mohammad SF, Burns GL, Pantalos GM, Kim J, Peng Y, Pitt WG, Reynolds LO, Olsen DB. Markers of thromboembolization in a bovine ex vivo left ventricular assist device model. ASAIO J 1994;40:M602-8. [PMID: 8555586 DOI: 10.1097/00002480-199407000-00070] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]  Open
Number Cited by Other Article(s)
1
Early Blood Clot Detection Using Forward Scattering Light Measurements Is Not Superior to Delta Pressure Measurements. BIOSENSORS 2023;13:1012. [PMID: 38131772 PMCID: PMC10741584 DOI: 10.3390/bios13121012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2023] [Revised: 11/30/2023] [Accepted: 12/02/2023] [Indexed: 12/23/2023]
2
Development of a real-time and quantitative thrombus sensor for an extracorporeal centrifugal blood pump by near-infrared light. BIOMEDICAL OPTICS EXPRESS 2018;9:190-201. [PMID: 29359096 PMCID: PMC5772574 DOI: 10.1364/boe.9.000190] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2017] [Revised: 11/07/2017] [Accepted: 12/07/2017] [Indexed: 06/07/2023]
3
Optical Dynamic Analysis of Thrombus Inside a Centrifugal Blood Pump During Extracorporeal Mechanical Circulatory Support in a Porcine Model. Artif Organs 2017;41:893-903. [DOI: 10.1111/aor.12862] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2016] [Revised: 07/07/2016] [Accepted: 08/19/2016] [Indexed: 12/25/2022]
4
Development of an Optical Detector of Thrombus Formation on the Pivot Bearing of a Rotary Blood Pump. Artif Organs 2016;40:834-41. [DOI: 10.1111/aor.12819] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2016] [Revised: 06/14/2016] [Accepted: 07/06/2016] [Indexed: 11/30/2022]
5
Feasibility of the Optical Imaging of Thrombus Formation in a Rotary Blood Pump by Near-Infrared Light. Artif Organs 2014;38:733-40. [DOI: 10.1111/aor.12377] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
6
Evaluation of optical propagation in blood for noninvasive detection of prethrombus blood condition. ASAIO J 2010;55:550-5. [PMID: 19812478 DOI: 10.1097/mat.0b013e3181be2e44] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]  Open
7
Doppler microembolic load predicts risk of thromboembolic complications in Novacor patients. J Thorac Cardiovasc Surg 2003;126:160-7. [PMID: 12878951 DOI: 10.1016/s0022-5223(03)00019-9] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
8
Light-scattering instrument to detect thromboemboli in blood. JOURNAL OF BIOMEDICAL OPTICS 2003;8:70-79. [PMID: 12542382 DOI: 10.1117/1.1527934] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2001] [Revised: 04/01/2002] [Accepted: 07/15/2002] [Indexed: 05/24/2023]
9
Mechanical Circulatory Support Sources of Emboli and Neurological Outcome. Semin Cardiothorac Vasc Anesth 2000. [DOI: 10.1053/vc.2000.6501] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
10
Clinical relevance of intracranial microembolic signals in patients with left ventricular assist devices. A prospective study. Stroke 1996;27:891-6. [PMID: 8623109 DOI: 10.1161/01.str.27.5.891] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA