• Reference Citation Analysis
  • v
  • v
  • Find an Article
  • Find an Author
Download
For: Thomas DC, Butler KC, Taylor LP, Le Blanc P, Rintoul TC, Petersen TV, Griffith BP, Kormos RL, Borovetz HS, Litwak P, Kameneva MV, Choi S, Burgreen GW, Wu Z, Antaki JF. Progress on development of the Nimbus-University of Pittsburgh axial flow left ventricular assist system. ASAIO J 1998;44:M521-4. [PMID: 9804485 DOI: 10.1097/00002480-199809000-00040] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
Number Cited by Other Article(s)
1
Wang JX, Smith JR, Bonde P. Energy Transmission and Power Sources for Mechanical Circulatory Support Devices to Achieve Total Implantability. Ann Thorac Surg 2014;97:1467-74. [DOI: 10.1016/j.athoracsur.2013.10.107] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2013] [Revised: 10/06/2013] [Accepted: 10/22/2013] [Indexed: 10/25/2022]
2
Loforte A, Montalto A, Ranocchi F, Casali G, Luzi G, Monica PLD, Sbaraglia F, Polizzi V, Distefano G, Musumeci F. Heartmate II axial-flow left ventricular assist system: management, clinical review and personal experience. J Cardiovasc Med (Hagerstown) 2009;10:765-71. [DOI: 10.2459/jcm.0b013e32832d495e] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
3
Fukunaga K, Funakubo A, Fukui Y. Newly developed ventricular assist device with linear oscillatory actuator. ASAIO J 2003;49:333-9. [PMID: 12790386 DOI: 10.1097/01.mat.0000065372.62948.eb] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]  Open
4
Coats AJ. Making choices in cardiology: difficulties of rationing and equality of access. Int J Cardiol 2001;78:209-12. [PMID: 11376821 DOI: 10.1016/s0167-5273(01)00464-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
5
Li G, Zhao H, Hu S, Zhu X, Wu Q, Ren B, Ma W. Initial hydrodynamic study on a new intraaortic axial flow pump: Dynamic aortic valve. Sci China C Life Sci 2001;44:199-206. [PMID: 18726438 DOI: 10.1007/bf02879326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2000] [Indexed: 05/26/2023]
6
Takatani S, Sakamoto T. Mechanical circulatory support devices for bridge to heart transplantation, bridge to recovery, or destination therapy. J Artif Organs 2000;3:75-84. [DOI: 10.1007/bf02479969] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
7
Clark RE, Zafirelis Z. Future devices and directions. Prog Cardiovasc Dis 2000;43:95-100. [PMID: 10935561 DOI: 10.1053/pcad.2000.7198] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
8
Nakata K, Yoshikawa M, Takano T, Sankai Y, Ohtsuka G, Glueck J, Fujisawa A, Makinouchi K, Yokokawa M, Nosé Y. Estimation of pump flow rate and abnormal condition of implantable rotary blood pumps during long-term in vivo study. Artif Organs 2000;24:315-9. [PMID: 10816208 DOI: 10.1046/j.1525-1594.2000.06534-4.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA