Gülcher OJ, Vis A, Peirlinck M, Kluin J. Balancing the ventricular outputs of pulsatile total artificial hearts. Artif Organs 2023; 47:1809-1817. [PMID: 37702086 DOI: 10.1111/aor.14641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2023] [Revised: 08/15/2023] [Accepted: 08/28/2023] [Indexed: 09/14/2023]
Abstract
BACKGROUND Maintaining balanced left and right cardiac outputs in a total artificial heart (TAH) is challenging due to the need for continuous adaptation to changing hemodynamic conditions. Proper balance in ventricular outputs of the left and right ventricles requires a preload-sensitive response and mechanisms to address the higher volumetric efficiency of the right ventricle. METHODS This review provides a comprehensive overview of various methods used to balance left and right ventricular outputs in pulsatile total artificial hearts, categorized based on their actuation mechanism. RESULTS Reported strategies include incorporating compliant materials and/or air cushions inside the ventricles, employing active control mechanisms to regulate ventricular filling state, and utilizing various shunts (such as hydraulic or intra-atrial shunts). Furthermore, reducing right ventricular stroke volume compared to the left often serves to balance the ventricular outputs. Individually controlled actuation of both ventricles in a pulsatile TAH seems to be the simplest and most effective way to achieve proper preload sensitivity and left-right output balance. Pneumatically actuated TAHs have the advantage to respond passively to preload changes. CONCLUSION Therefore, a pneumatic TAH that comprises two individually actuated ventricles appears to be a more desirable option-both in terms of simplicity and efficacy-to respond to changing hemodynamic conditions.
Collapse
Affiliation(s)
- Oskar J Gülcher
- Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, Location University of Amsterdam, Amsterdam, The Netherlands
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Annemijn Vis
- Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, Location University of Amsterdam, Amsterdam, The Netherlands
| | - Mathias Peirlinck
- Department of Biomechanical Engineering, Delft University of Technology, Delft, The Netherlands
| | - Jolanda Kluin
- Department of Cardiothoracic Surgery, Amsterdam University Medical Centers, Location University of Amsterdam, Amsterdam, The Netherlands
- Department of Cardiothoracic Surgery, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
| |
Collapse
|
2
|
Hildebrand S, Diedrich M, Brockhaus M, Finocchiaro T, Cuenca E, De Ben H, Steinseifer U, Schmitz-Rode T, Jansen SV. Controlling the flow balance: In vitro characterization of a pulsatile total artificial heart in preload and afterload sensitivity. Artif Organs 2021; 46:71-82. [PMID: 34287976 DOI: 10.1111/aor.14042] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 06/08/2021] [Accepted: 07/12/2021] [Indexed: 12/01/2022]
Abstract
The objective of this study is to identify the preload and afterload sensitivity of the ReinHeart TAH 2.0. For adequate left-right flow balance, the concept of a reduced right stroke volume (by about 10%) and active adaption of the right diastole duration are evaluated concerning the controllability of the flow balance. This study used an active mock circulation loop to test a wide range of preload and afterload conditions. Preload sensitivity was tested at atrial pressures (APs) between 4 and 20 mm Hg. Left afterload was varied in a range of 60-140 mm Hg mean aortic pressure (MAP), right afterload was simulated between 15 and 40 mm Hg. Four scenarios were developed to verify that the flow difference fully covers the defined target range of 0-1.5 L/min. Although a positive correlation between inlet pressure and flow is identified for the right pump chamber, the left pump chamber already fills completely at an inlet pressure of 8-10 mm Hg. With increasing afterload, both the left and right flow decrease. A positive flow balance (left flow exceeds right flow) is achieved over the full range of tested afterloads. At high APs, the flow difference is limited to a maximum of 0.7 L/min. The controllability of flow balance was successfully evaluated in four scenarios, revealing that a positive flow difference can be achieved over the full range of MAPs. Under physiological test conditions, the linear relationship between flow and heart rate was confirmed, ensuring good controllability of the TAH.
Collapse
Affiliation(s)
- Stephan Hildebrand
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Mario Diedrich
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Moritz Brockhaus
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | | | | | | | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Sebastian Victor Jansen
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
3
|
In vitro performance investigation of SynCardia™ Freedom® driver via patient simulator mock loop. Int J Artif Organs 2016; 39:502-508. [PMID: 27768204 DOI: 10.5301/ijao.5000524] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/22/2016] [Indexed: 12/31/2022]
Abstract
PURPOSE The gold standard therapy for patients with advanced heart failure is heart transplant. The gap between donors and patients in waiting lists promoted the development of circulatory support devices, such as the total artificial heart (TAH). Focusing on in vitro tests performed with CardioWest™ TAH (CW) driven by the SynCardia Freedom® portable driver (FD) the present study goals are: i) prove the reliability of a hydraulic circuit used as patient simulator to replicate a quasi-physiological scenario for various hydrodynamic conditions, ii) investigate the hydrodynamic performance of the CW FD, iii) help clinicians in possible interpretation of clinical cases outcomes. METHODS In vitro tests were performed using a mechanic-hydraulic patient simulator. Cardiac output (CO), CW ventricles filling, atrial, ventricles, aortic and pulmonary artery pressures were measured for different values of vascular resistance in both systemic (SVR) and pulmonary (PVR) physiological range. RESULTS After increasing the PVR, the left atrial pressure decreased according to the expected physiological trend, while aortic pressure remained almost stable, proving the ability of the simulator to mimic a physiological scenario. Unexpectedly, the mean pulmonary artery pressure (PPA) was found to increase above 30 mmHg in the range of physiological PVR (2.6 WU) and for constant CO. CONCLUSIONS The increase in PPA is probably associated with the pre-set driving setup of the FD. The finding suggests a possible explanation of the clinical course of a patient who experienced complications soon after being supported by the FD, with the occurrence of dyspnea and pulmonary edema despite a high cardiac index.
Collapse
|
4
|
Fukamachi K, Shiose A, Massiello A, Horvath DJ, Golding LAR, Lee S, Starling RC. Preload sensitivity in cardiac assist devices. Ann Thorac Surg 2012; 95:373-80. [PMID: 23272869 DOI: 10.1016/j.athoracsur.2012.07.077] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/05/2012] [Revised: 07/20/2012] [Accepted: 07/26/2012] [Indexed: 11/18/2022]
Abstract
With implantable cardiac assist devices increasingly proving their effectiveness as therapeutic options for end-stage heart failure, it is important for clinicians to understand the unique physiology of device-assisted circulation. Preload sensitivity as it relates to cardiac assist devices is derived from the Frank-Starling relationship between human ventricular filling pressures and ventricular stroke volume. In this review, we stratify the preload sensitivity of 17 implantable cardiac assist devices relative to the native heart and discuss the effect of preload sensitivity on left ventricular volume unloading, levels of cardiac support, and the future development of continuous-flow total artificial heart technology.
Collapse
Affiliation(s)
- Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA.
| | | | | | | | | | | | | |
Collapse
|
5
|
Fukamachi K, Horvath DJ, Massiello AL, Fumoto H, Horai T, Rao S, Golding LAR. An innovative, sensorless, pulsatile, continuous-flow total artificial heart: device design and initial in vitro study. J Heart Lung Transplant 2009; 29:13-20. [PMID: 19782599 DOI: 10.1016/j.healun.2009.05.034] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2009] [Revised: 05/27/2009] [Accepted: 05/27/2009] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND We are developing a very small, innovative, continuous-flow total artificial heart (CFTAH) that passively self-balances left and right pump flows and atrial pressures without sensors. This report details the CFTAH design concept and our initial in vitro data. METHODS System performance of the CFTAH was evaluated using a mock circulatory loop to determine the range of systemic and pulmonary vascular resistance (SVR and PVR) levels over which the design goal of a maximum absolute atrial pressure difference of 10 mm Hg is achieved for a steady-state flow condition. Pump speed was then modulated at 2,600 +/- 900 rpm to induce flow and arterial pressure pulsation to evaluate the effects of speed pulsations on the system performance. An automatic control mode was also evaluated. RESULTS Using only passive self-regulation, pump flows were balanced and absolute atrial pressure differences were maintained at <10 mm Hg over a range of SVR (750 to 2,750 dyne.sec.cm(-5)) and PVR (135 to 600 dyne.sec.cm(-5)) values far exceeding normal levels. The magnitude of induced speed pulsatility affected relative left/right performance, allowing for an additional active control to improve balanced flow and pressure. The automatic control mode adjusted pump speed to achieve targeted pump flows based on sensorless calculations of SVR and CFTAH flow. CONCLUSIONS The initial in vitro testing of the CFTAH with a single, valveless, continuous-flow pump demonstrated its passive self-regulation of flows and atrial pressures and a new automatic control mode.
Collapse
Affiliation(s)
- Kiyotaka Fukamachi
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio 44195, USA
| | | | | | | | | | | | | |
Collapse
|
6
|
Abstract
Incompetent inflow valves have been reported with clinical pulsatile left ventricular assist devices that use bioprosthetic valves. Suspected as the cause of premature valve failure within these devices, absolute pressures and instantaneous pressure changes were evaluated in the MagScrew total artificial heart (TAH). The MagScrew TAH is a passively filling pulsatile pump which uses a reciprocating magnetic actuating mechanism under various control modes to propel blood into circulation. Both right and left ejection speeds were modulated and optimized at the onset of hydraulic eject. These various speed profiles were evaluated in vitro at 220 beats per minute (bpm), 100% pump fill, mean aortic pressure of 100 mm Hg and mean pulmonary artery pressure of 20 mm Hg. The pressure inside the left and right pump chambers was measured with Millar Mikro-Tip catheter and captured using Power Lab at a rate of 40 kHz. The pump chamber peak pressure, operating with unmodified eject speeds, measured on average 183 mm Hg for the left and 133 mm Hg for the right. Eject speed profiling for both pumps reduced the peak pressure by 10% and 28% for the left and right pump, respectively. Future studies will assess software controlled optimization of the eject speed profiles under any operating condition and how effective it is in vivo.
Collapse
|
7
|
Casas F, Weber S, Klatte R, Luangphakdy V, Smith WA. Cycle testing of the MagScrew total artificial heart external battery pack. Artif Organs 2007; 31:698-702. [PMID: 17725697 DOI: 10.1111/j.1525-1594.2007.00444.x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
MagScrew total artificial heart (TAH) external battery pack (EBP) cycle bench testing was conducted on two Wilson Greatbatch (Clarence, NY, USA) lithium ion EBPs over a period of 22 months during continuous charge and discharge cycles under a simulated TAH system current requirement. A custom electronic load was developed to simulate the MagScrew current waveforms typically observed during nominal operation. These current load profiles were applied to the EBP under test during a voltage-defined discharge cycle. EBP endurance indicated a 240-min discharge cycle on a new battery diminishing linearly to 175 min after 800 cycles. A second linear trend started at this knee with 150 min of discharge time at 850 cycles until 10 min at 1600 cycles. Even at 1300 cycles, the EBP could still provide enough power for 60 min of nominal operation. In conclusion, the endurance performance of this EBP was satisfactory while exhibiting a predictable wear-out trend.
Collapse
Affiliation(s)
- Fernando Casas
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic Foundation, Cleveland, OH 44195, USA.
| | | | | | | | | |
Collapse
|
8
|
Kamohara K, Weber S, Klatte RS, Ootaki Y, Akiyama M, Kopcak MW, Luangphakdy V, Flick CR, Chen JF, Navia JL, Smith WA, Fukamachi K. Replacement of the left-side valves of an implanted total artificial heart. ASAIO J 2006; 52:368-72. [PMID: 16883114 DOI: 10.1097/01.mat.0000227731.46835.1e] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The MagScrew total artificial heart (TAH) is under development. Despite its anticipated durability and reliability, the possibility of a bioprosthetic valve malfunction exists. As a result, the potential for valve replacement surgery, instead of device replacement, would be desirable after a TAH implant. In two of our 90-day animal experiments, we successfully replaced the left-side valves through a left thoracotomy opposite to the right-sided incision site for the initial TAH implant. The results of these cases suggest that the left-side valves could also be replaced through a left thoracotomy approach in humans. To confirm the ability to access the left-side valves in humans, four human cadaver studies were performed with the use of a mock pump designed for human application. This report describes the operative techniques for left-side valve replacement in animals and discusses the advantages of a left thoracotomy in clinical situations, based on results from the human cadaver studies.
Collapse
Affiliation(s)
- Keiji Kamohara
- Department of Biomedical Engineering, Lerner Research Institute, Cleveland Clinic, Cleveland, Ohio, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
9
|
Weber S, Kamohara K, Klatte RS, Luangphakdy V, Flick C, Chen JF, Casas F, Ootaki Y, Kopcak M, Akiyama M, Hirschman GB, Chapman PA, Donahue A, Wetterau W, Prisco C, Mast R, Sherman C, Fukamachi K, Smith WA. MagScrew TAH: an update. ASAIO J 2006; 51:xxxvi-xlvi. [PMID: 16340348 DOI: 10.1097/01.mat.0000187395.29817.36] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
The MagScrew Total Artificial Heart (TAH) system is the result of a close collaboration among the Cleveland Clinic Foundation, Foster Miller Technologies, Wilson Greatbatch Ltd, and Whalen Biomedical Inc. The system components are the thoracic blood pumping unit with attached compliance chamber and refill port, implantable electronic control unit, implantable battery pack, transcutaneous energy transmission system, external battery pack, and a telemetry system for communication with the electronic control unit. System in vitro tests are underway for system characterization and durability demonstration, whereas in vivo tests were conducted to evaluate system performance and biocompatibility under physiologic conditions. The passively filling pump uses a left master alternate left and right ejection control mode and has a Starling law-like response to venous pressure. The in vitro tests documented excellent hydraulic pump performance with high device output of over 9 l/min at left atrial pressures below 12 mm Hg. Atrial balance was well maintained under all test conditions. The in vivo tests demonstrated good biocompatibility without use of anticoagulant therapy. Experimental durations have ranged between 0 and 92 days. Postexplant evaluation of tissue samples did not reveal any sign of thromboembolic events or tissue damage due to device operation.
Collapse
Affiliation(s)
- Stephan Weber
- The Cleveland Clinic Foundation, Cleveland, OH 44195, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Patel SM, Throckmorton AL, Untaroiu A, Allaire PE, Wood HG, Olsen DB. The Status of Failure and Reliability Testing of Artificial Blood Pumps. ASAIO J 2005; 51:440-51. [PMID: 16156311 DOI: 10.1097/01.mat.0000169083.90253.3c] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Artificial blood pumps are today's most promising bridge-to-transplant, bridge-to-recovery, and destination therapy solutions for patients with congestive heart failure. There is a critical need for increased reliability and safety as the next generation of artificial blood pumps approach final development for long-term destination therapy. To date, extensive failure and reliability studies of these devices are considered intellectual property and thus remain unpublished. Presently, the Novacor N100PC, Thoratec VAD, and HeartMate LVAS (IP and XVE) comprise the only four artificial blood pumps commercially available for the treatment of congestive heart failure in the United States. The CardioWest TAH recently received premarket approval from the US Food and Drug Administration. With investigational device exemptions, the AB-180, AbioCor, LionHeart, DeBakey, and Flowmaker are approved for clinical testing. Other blood pumps, such as the American BioMed-Baylor TAH, CorAide, Cleveland Clinic-Nimbus TAH, HeartMate III, Hemadyne, and MagScrew TAH are currently in various stages of mock loop and animal testing, as indicated in published literature. This article extensively reviews in vitro testing, in vivo testing, and the early clinical testing of artificial blood pumps in the United States, as it relates to failure and reliability. This detailed literature review has not been published before and provides a thorough documentation of available data and testing procedures regarding failure and reliability of these various pumps.
Collapse
Affiliation(s)
- Sonna M Patel
- Department of Biomedical Engineering University of Virginia, Charlottesville, VA, USA
| | | | | | | | | | | |
Collapse
|
11
|
Schenk S, Weber S, Luangphakdy V, Klatte RS, Flick CR, Chen JF, Kopcak MW, Ootaki Y, Kamohara K, Hirschman GB, Vitale NG, Chapman PA, Smith WA, Fukamachi K. Magscrew Total Artificial Heart In Vivo Performance Above 200 Beats Per Minute. Ann Thorac Surg 2005; 79:1378-83; discussion 1383. [PMID: 15797082 DOI: 10.1016/j.athoracsur.2004.03.064] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 03/15/2004] [Indexed: 10/25/2022]
Abstract
PURPOSE Downsizing pulsatile devices requires an increase of beat rate if flow capacity is to be maintained. We applied this concept to the preclinical MagScrew total artificial heart (TAH). DESCRIPTION The device fills passively with a stroke volume of 45 ml and beat rates up to 250 beats per minute (bpm). EVALUATION Stable hemodynamics were observed during a 30-day bovine implant with a flow of 8.7 +/- 1.2 L/min at beat rates of 204 +/- 18 bpm. Device filling was exceptional up to 250 bpm generating flow of greater than 12 L/min. Beat rate adapted to preload in a way similar to a Frank-Starling response. Left and right atrial pressures were balanced. The aortic pulse pressure was 49-70 mm Hg, which translates to a pulsatility index of 0.49-0.77. Organ functions were preserved and blood damage did not occur. CONCLUSIONS Increasing the beat rate while downsizing the MagScrew TAH was successful with strong flow generation by passive filling. Pulsatility was maintained at high beat rates. This innovative approach may be used to develop small pulsatile pumps.
Collapse
Affiliation(s)
- Soren Schenk
- Department of Biomedical Engineering, The Cleveland Clinic Foundation, Cleveland, Ohio 44195, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Schenk S, Weber S, Luangphakdy V, Flick CR, Chen JF, Inoue M, Kopcak MW, Ootaki Y, Doi K, Dessoffy R, Hirschman GB, Vitale NG, Chapman PA, Smith WA, Fukamachi K. In vivo performance and biocompatibility of the MagScrew ventricular assist device. ASAIO J 2004; 49:594-8. [PMID: 14524571 DOI: 10.1097/01.mat.0000084107.46300.21] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Currently available ventricular assist devices (VADs) have limitations in long-term durability and blood compatibility. We evaluated a prototype of a pulsatile MagScrew VAD for in vivo hemodynamic performance and biocompatibility. The device is composed of an actuator, blood pump housing, diaphragm, pusher plate, and bioprosthetic valves. Its protein-coated ("biolized") blood-contacting surface inhibits clot formation. Forces between moving parts of the actuator are transmitted magnetically, eliminating a primary source of friction and wear. The pump fills passively and is highly preload sensitive. The device was implanted into three calves for 90, 10, and 57 days, respectively. No anticoagulants were given postoperatively. The device functioned without technical problems during the entire course of each experiment, with mean device flow ranging between 5.4 and 9.0 L/min. Autopsy of the first two calves revealed no sign of embolization and clean blood-contacting surfaces of the devices. The third experiment was complicated by a prosthetic valve endocarditis with infectious embolization, and a few small depositions were found in the pump. In conclusion, the MagScrew VAD has demonstrated a high level of performance and biocompatibility in three calves studied for 10-90 days. Vigorous development is in progress to bring this device to preclinical readiness and thus provide surgeons with the VAD of choice for permanent implantation.
Collapse
Affiliation(s)
- Soren Schenk
- Department of Biomedical Engineering, Lerner Research Institute, The Cleveland Clinic Foundation, 9500 Euclid Avenue, Cleveland, OH 44195, USA
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|