Gaio NM, Kruse LM. Closed Reduction Percutaneous Pinning Versus Open Reduction With Plate and Screw Fixation in Management of Unstable Proximal Phalangeal Fractures: A Systematic Review and Meta-analysis. Hand (N Y) 2023:15589447231189762. [PMID: 37599408 DOI: 10.1177/15589447231189762] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 08/22/2023]
Abstract
BACKGROUND Proximal phalanx fractures are common, with surgical fixation indicated for unstable fractures. Traditionally, closed reduction percutaneous pinning (CRPP) resulted in decreased stiffness and tendon irritation compared to open reduction internal fixation (ORIF). We hypothesized that more recent studies would have more similar outcomes to CRPP. The purpose of this study was to compare CRPP and ORIF in terms of range of motion, Disabilities of the Arm, Shoulder, and Hand (DASH) scores, and complications. METHODS Four electronic databases were queried from 2010 to present. Following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, two independent reviewers performed a two-step review process to identify relevant articles. Patient demographics, total active motion (TAM), DASH, and complications were extracted. The methodological quality of each study included was assessed independently. Meta-analysis was performed for comparative trials. RESULTS Fourteen studies met inclusion criteria including four comparative studies: Thirteen studies included TAM. The weighted average TAM was 228 ± 34° for CRPP and 223 ± 32° for ORIF (P = .07 with 95% confidence interval (CI), -0.5 to 10.5). Seven studies evaluated DASH scores; weighted average was 8.2 ± 8.9 for CRPP and 11.7 ± 6.5 for ORIF (P < .01 with 95% CI, 1.8-5.2). Two studies directly compared CRPP to ORIF, favoring ORIF for both TAM with d = 1.07 and DASH with d = 0.23. Rates of tenolysis or hardware removal were higher for ORIF (P < .01). CONCLUSIONS New literature suggests more equipoise with regard to treatment of proximal phalanx fracture with CRPP versus ORIF. TYPE OF STUDY/LEVEL OF EVIDENCE Meta-analysis, Level II.
Collapse
|
2
|
Biehl C, Stötzel S, Schock L, Szalay G, Heiss C. Treatment of hand and finger fractures with the Stryker Hand Plating System. GERMAN MEDICAL SCIENCE : GMS E-JOURNAL 2022; 20:Doc03. [PMID: 35465637 PMCID: PMC9006317 DOI: 10.3205/000305] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/26/2021] [Revised: 11/01/2021] [Indexed: 11/18/2022]
Abstract
Objectives: 10% of all fractures occur in the fingers and metacarpal region. Early mobilization with preservation of grip function is the goal of any therapy for these injuries. Osteosyntheses with plates are used in complex fractures that do not allow any other treatment. The aim of this retrospective study was to evaluate the performance and safety of the Stryker Hand System. Patients and methods: Between 2010 and 2019, 190 patients underwent surgical treatment with plates for fractures of the fingers and metacarpal region. Of these, 140 operations could be analyzed according to the inclusion criteria based on clinical and radiological parameters. Results: Three-quarters of the patients were male. The mean age at the time of surgery was 39.3±16 years. Falling was the leading cause for hand fractures, and the most common were fractures of the shaft (>52%). More than 15% were complex hand injuries with more than one fractured finger. The majority of patients were healthy non-smokers without systemic diseases and relevant medical history. Conclusion: The Stryker Finger Plates are safe implants with good results that are consistent with those reported in the literature. The trend is also toward stable-angle implants for fracture treatment of the finger, in order to enable the earliest possible functional, safe mobilization. Level of Evidence: Level: IV; outcome-study, retrospective.
Collapse
Affiliation(s)
- Christoph Biehl
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Gießen, Germany,Experimental Trauma Surgery, Justus Liebig University of Gießen, Germany,*To whom correspondence should be addressed: Christoph Biehl, Department of Trauma, Hand and Reconstructive Surgery, University Hospital Gießen, Rudolf-Buchheim-Str. 7, 35392 Gießen, Germany, E-mail:
| | - Sabine Stötzel
- Experimental Trauma Surgery, Justus Liebig University of Gießen, Germany
| | - Lydia Schock
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Gießen, Germany,Experimental Trauma Surgery, Justus Liebig University of Gießen, Germany
| | - Gabor Szalay
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Gießen, Germany,Experimental Trauma Surgery, Justus Liebig University of Gießen, Germany
| | - Christian Heiss
- Department of Trauma, Hand and Reconstructive Surgery, University Hospital Gießen, Germany,Experimental Trauma Surgery, Justus Liebig University of Gießen, Germany
| |
Collapse
|
3
|
Baumgartner RE, Federer AE, Guerrero EM, Mithani SK, Ruch DS, Richard MJ. Complications of Low-Profile Plate Fixation in Metacarpal Fractures. Orthopedics 2021; 44:e91-e94. [PMID: 33002179 DOI: 10.3928/01477447-20200925-02] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/07/2019] [Accepted: 01/28/2020] [Indexed: 02/03/2023]
Abstract
High complication rates have been reported using conventional plating systems to treat metacarpal fractures. This study investigated complication rates in metacarpal fractures treated with low-profile anatomic plates. A retrospective chart review was performed of patients with metacarpal fractures who were treated with open reduction and internal fixation using low-profile anatomic plates at a single institution from January 2010 to February 2017. Patients with concomitant tendon injury, open fractures, prior same metacarpal fracture, or thumb metacarpal fracture were excluded. A total of 79 patients with 110 metacarpal fractures were included. The primary outcome was the presence of a complication, defined as superficial or deep infection, delayed wound healing, delayed union, nonunion, major or minor extensor lag or stiffness 90 days postoperatively, or return to the operating room. Eleven fractures (10%) had 1 or more complications. Complications included 6 fractures (5%) with major extensor lag or stiffness, 4 fractures (4%) with minor extensor lag or stiffness, 1 fracture (1%) with delayed radiographic union that did not require operative intervention, and 1 fracture (1%) with return to the operating room for removal of hardware. In this retrospective study, treatment of metacarpal fractures with low-profile plate fixation resulted in a 10% overall complication rate and a 1% reoperation rate; this rate is significantly less than reported in previous literature prior to the widespread use of low-profile plates. This study suggests treatment of patients with metacarpal fractures using low-profile plating systems provides a reliable solution with acceptable complication rates. [Orthopedics. 2021;44(1):e91-e94.].
Collapse
|
4
|
Timing for Surgical Stabilization with K-wires after Open Fractures of Proximal and Middle Phalangeal Shaft. Sci Rep 2017; 7:11359. [PMID: 28900294 PMCID: PMC5595815 DOI: 10.1038/s41598-017-11918-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2017] [Accepted: 08/31/2017] [Indexed: 12/02/2022] Open
Abstract
The optimal timing for surgical stabilization after open fractures of proximal and middle phalangeal shaft remained unclear. Total 147 patients with single open fracture in proximal or middle phalangeal shaft (arrived within 8 hours) who received K-wire fixation from June 2012 to June 2015 were included for analysis. The timing for surgical stabilization of fractures (immediate or delayed) was decided according to the surgeons’ preferences. The Michigan hand outcomes questionnaire (MHQ) scores, grip strength and total active motion (TAM) one year after the initial surgery were similar between the two groups. There was no significant difference in the incidence of tenosynovitis, bone nonunion. The overall infection rate in immediate fixation group was slightly but not significantly higher compared with the delayed fixation group (29.2% versus 20.7% P = 0.212). However, patients with both palmar and dorsal wounds who received immediate fixation had much higher infection rate compared with delayed fixation (52.6% versus 22.7%, P = 0.047). The immediate fixation could reduce costs and the period of hospitalization. Open fractures with both palmar and dorsal wounds should be treated with delayed fixation of K-wires otherwise stabilized immediately after injury.
Collapse
|
5
|
Extensor tendon splitting versus extensor tendon sparing approach for miniplate fixation of extraarticular proximal phalangeal fractures. CURRENT ORTHOPAEDIC PRACTICE 2016. [DOI: 10.1097/bco.0000000000000428] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
6
|
Li G, Liu S, Chen G, Li Z, Liu Y, Sun G, Lu Q, Li X, Tan J, Guan M. Comparison of Clinical Outcomes of Phalangeal Fracture Treated with Dorsolateral Approach or Post-middle Approach Using AO Mini Titanium Plate. Indian J Surg 2016; 77:657-61. [PMID: 26730082 DOI: 10.1007/s12262-013-0968-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2013] [Accepted: 08/15/2013] [Indexed: 10/26/2022] Open
Abstract
The aim of this study is to investigate the clinical outcomes of various fixation methods for proximal phalangeal fractures with Arbeitsgemeinschaft für Osteosynthesefragen (AO) mini titanium plate by dorsolateral approach or post-middle approach. Clinical results of 62 fingers of 53 patients with proximal phalangeal fracture were evaluated. For dorsolateral approach, the lateral bundle of the extensor tendon was drawn away to expose the fracture part of the bone. After reduction, the plate was located at the dorsolateral side of the bone. For post-middle approach, the extensor tendon was split to expose the fracture part of the bone. After reduction, the plate was fixed to the proximal phalangeal side of the bone, and the extensor tendon was repaired with 3-0 nonabsorbable silk sutures. We found low overall complication rates in both groups. The mean total active motion (TAM) for the dorsolateral group and post-middle group was 234.60° ± 22.63° and 221.08° ± 25.69°, respectively. There was a statistical significance between the two groups (P = 0.037 < 0.05), indicating that TAM was notably affected by various fixation methods. With AO mini titanium plate, movement in dorsolateral approach group was significantly higher than in post-middle approach group. Dorsolateral approach is an acceptable technique of incision for proximal phalangeal fractures.
Collapse
Affiliation(s)
- Guang Li
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Shen Liu
- Department of Orthopaedics, Shanghai 6th People's Hospital, Shanghai Jiaotong University, Shanghai, 200233 China
| | - Guoting Chen
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Zengchun Li
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Yangzhou Liu
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Guixin Sun
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Qingyou Lu
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Xia Li
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Jun Tan
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| | - Ming Guan
- Department of Emergency Trauma, Shanghai East Hospital, Tongji University School of Medicine, No. 150 Jimo Road, Shanghai, 200120 China
| |
Collapse
|
7
|
Shimizu T, Omokawa S, Akahane M, Murata K, Nakano K, Kawamura K, Tanaka Y. Predictors of the postoperative range of finger motion for comminuted periarticular metacarpal and phalangeal fractures treated with a titanium plate. Injury 2012; 43:940-5. [PMID: 22459897 DOI: 10.1016/j.injury.2012.02.011] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2011] [Revised: 01/26/2012] [Accepted: 02/13/2012] [Indexed: 02/02/2023]
Abstract
BACKGROUND Plate and screw fixation was introduced for complex fractures of the hand. Several risk factors for a poor functional outcome have been identified, but there is a paucity of evidence regarding predictors of finger stiffness in difficult hand fractures. The purpose of this prospective cohort study was to identify independent prognostic factors of the postoperative total active motion (%TAM) in the treatment of metacarpal and phalangeal fractures. METHODS Seventy-two patients (62 males, 10 females; 37±15 years) with periarticular fractures involving metaphyseal comminution and displacement were evaluated at a minimum of 1 year following surgery. There were 49 phalangeal bone fractures, 30 intra-articular fractures and 20 associated soft-tissue injuries. The locations of plate placement were lateral in 42 patients and dorsal in 30. The mean duration from injury to surgery was 7.6 days (range, 0-40 days). There were eight examined variables related to patient characteristics (age, gender and hand dominance), fracture characteristics (fracture location, joint involvement and associated soft-tissue injury) and surgical variables (location of plate placement and duration from injury to surgery). Univariate and multivariate linear regression analysis were used to identify the degree to which variables affect %TAM at the final follow-up. RESULTS Univariate analysis indicated moderate correlations of %TAM with fracture location, associated soft-tissue injury and age. Multiple linear regression modelling including fracture location, age and associated soft-tissue injury resulted in formulae that could account for 46.3% of the variability in %TAM: fracture location (β=-0.388, p<0.001), age (β=-0.339, p<0.001) and associated soft-tissue injury (β=-0.296, p=0.002). CONCLUSION Phalangeal fracture, increasing age and associated soft-tissue injury were important risk factors to identify the postoperative %TAM in the treatment of comminuted periarticular metacarpal or phalangeal fracture with a titanium plate.
Collapse
Affiliation(s)
- Takamasa Shimizu
- Department of Orthopedic Surgery, Nara Medical University, Nara, Japan
| | | | | | | | | | | | | |
Collapse
|
8
|
Hing-Cheong W, Hin-Keung W, Kam-Yiu W. Stainless Steel 2.0-mm Locking Compression Plate Osteosynthesis System for the Fixation of Comminuted Hand Fractures in Asian Adults. JOURNAL OF ORTHOPAEDICS, TRAUMA AND REHABILITATION 2011. [DOI: 10.1016/j.jotr.2011.04.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022] Open
Abstract
Objective The aim of this retrospective study was to analyse the clinical outcome of the application of stainless steel 2.0-mm locking compression plate (LCP) system for the treatment of comminuted hand fractures in Asian adults. Methods Six patients who had comminuted hand fractures were treated by open reduction and internal fixation with the application of stainless steel 2.0-mm LCP (AO Compact Hand System; Synthes, Oberdorf, Switzerland) from December 2009 to October 2010. The total arc of motion of fingers, grip power, complications, and additional surgery were recorded. Results Three out of six patients eventually restored good hand functions in terms of the total arc of finger motion (>220°) and grip power. The commonest complication was skin impingement in finger region by the implant (4 cases). Another common complication was restricted range of motion (3 cases). One patient had minimal degree of malrotation of his left little finger. Additional surgery was required in all the patients for implant removal (6 cases), tenolysis (3 cases), and capsulotomy (2 cases). Conclusions The stainless steel 2.0-mm LCP is useful for the fixation of unstable comminuted hand fractures, especially in metacarpal bones, because of its advantage of better stability, which allows more aggressive rehabilitation. However, its design is not very versatile and, therefore, limits its use in the finger region. Its bulkiness frequently causes implant impingement. The patients must be informed about the chance of implant removal later.
Collapse
Affiliation(s)
- Wong Hing-Cheong
- Department of Orthopaedics and Traumatology, Princess Margaret Hospital, Lai Chi Kok, Kowloon, Hong Kong
| | - Wong Hin-Keung
- Department of Orthopaedics and Traumatology, Princess Margaret Hospital, Lai Chi Kok, Kowloon, Hong Kong
| | - Wong Kam-Yiu
- Department of Orthopaedics and Traumatology, Princess Margaret Hospital, Lai Chi Kok, Kowloon, Hong Kong
| |
Collapse
|
9
|
Soni A, Gulati A, Bassi JL, Singh D, Saini UC. Outcome of closed ipsilateral metacarpal fractures treated with mini fragment plates and screws: a prospective study. J Orthop Traumatol 2011; 13:29-33. [PMID: 22080220 PMCID: PMC3284659 DOI: 10.1007/s10195-011-0166-7] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/19/2010] [Accepted: 10/24/2011] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Closed multiple metacarpal fractures are considered highly unstable and are more prone to poor functional outcome. The authors assess the functional outcome of mini fragment plate fixation in closed ipsilateral multiple metacarpal fractures. PATIENTS AND METHODS In 21 patients with closed ipsilateral multiple metacarpal fractures treated with open reduction and internal fixation using mini fragment plate, functional outcome was assessed using the American Society for Surgery of the Hand (ASSH) Total Active Flexion (TAF) score and the Disabilities of the Arm, Shoulder, and Hand (DASH) scoring system. RESULTS Union rate of 100% was achieved. Functional outcome was excellent in 85.71% (18 of 21) and good in 9% (2 of 21) of patients. Average DASH score was 8.47 (range 1-26). Five cases of infection (two deep, three superficial) were reported, which subsided with dressings and antibiotics. CONCLUSIONS Plate fixation is a good option for treating closed ipsilateral multiple metacarpal fractures, providing rigid fixation for early mobilization and good functional outcome.
Collapse
Affiliation(s)
- Ashwani Soni
- Department of Orthopedics, Post Graduate Institute of Medical Education and Research, Chandigarh 160012, India.
| | | | | | | | | |
Collapse
|
10
|
Humane killers, human injury: functional outcome of vole captive bolt injuries. THE JOURNAL OF TRAUMA 2009; 67:617-23. [PMID: 19741410 DOI: 10.1097/ta.0b013e3181823500] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND High-pressure blast injuries to the hand due to vole captive bolt devices are serious injuries that are to a great extent unknown to emergency care operators and trauma surgeons. There is no study on the functional outcome of these patients. METHODS We assessed the functional outcome of patients with injuries inflicted by vole captive bolt devices. Therefore, a protocol consisting of a physical examination and an assessment of static muscle power (grip and pinch strength) was performed. To capture the subjective experience of patients regarding their injury related disability and impairment, the DASH follow-up questionnaire was used. Based on clinical/radiologic findings and outcome, a classification of this unique subgroup of blast injuries was developed. RESULTS The functional outcome of 34 patients suffering hand injuries due to captive bolt devices between 2004 and 2007 was assessed. A significant reduction of static muscle testing parameters compared with the uninjured hand was revealed. Fourteen patients lost a digit. Average time lost from work was 5.4 weeks. CONCLUSION Vole captive bolt device-related hand injuries are followed by deterioration of hand function. The present observations alarmed national authorities. The manufacturers were required to take engineering and teaching measures to rule out handling errors that were identified as leading cause of injury.
Collapse
|
11
|
Orbay JL, Touhami A. The treatment of unstable metacarpal and phalangeal shaft fractures with flexible nonlocking and locking intramedullary nails. Hand Clin 2006; 22:279-86. [PMID: 16843794 DOI: 10.1016/j.hcl.2006.02.017] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Metacarpal and phalangeal shaft fracture fixation can be achieved by closed IM nailing. This technique provides sufficient stability to commence early unsupported joint motion and minimize soft-tissue irritation and scar formation. Stability is enhanced by proximal nail locking; a measure that extends the indications to spiral and comminuted fractures. The surgical technique is simple but requires attention to detail.
Collapse
Affiliation(s)
- Jorge L Orbay
- Miami Hand Center, 8905 SW 87th Avenue, Suite 100, Miami, FL 33176, USA.
| | | |
Collapse
|
12
|
Tratamiento quirúrgico de las fracturas diafisarias de metacarpianos. Rev Esp Cir Ortop Traumatol (Engl Ed) 2006. [DOI: 10.1016/s1888-4415(06)76357-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
13
|
Trevisan C, Morganti A, Casiraghi A, Marinoni EC. Low-severity metacarpal and phalangeal fractures treated with miniature plates and screws. Arch Orthop Trauma Surg 2004; 124:675-80. [PMID: 15602676 DOI: 10.1007/s00402-004-0745-7] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2003] [Indexed: 10/26/2022]
Abstract
INTRODUCTION The results reported in the literature of metacarpal and phalangeal fractures treated with miniature plates and screws are scarce and contradictory. The aim of our study was to evaluate the functional results after low-severity metacarpal and phalangeal fractures treated by miniature plates and screws. MATERIALS AND METHODS We retrospectively reviewed 44 patients of a consecutive series with 56 low-severity metacarpal and/or phalangeal fractures stabilized with miniature plates and screws with a mean follow-up of 24 months to assess objective and subjective outcomes and complications. The objective assessment included measurement of the range of motion (ROM) of the involved finger, prehension, sensory function and strength. The subjective evaluation assessed the impairment and pain felt by the patient. RESULTS At the final check-up, average total active movement of the involved digit was 256 degrees (range 175 degrees -260 degrees ), and average score for prehension was 49.3 (range 30-50), with 41 patients with a full score. The Jamar test pointed to a significant reduction in grip strength (-5.2%) of the injured hand compared with the other hand. Average subjective impairment score for all the fractures was 15.5 (range 10-16), with 39 patients having a score between 16 and 14 (no impairment). Fracture reduction was anatomic in 42 fractures (75%), satisfactory in 11 (19.6%) and unsatisfactory in 3 (5.4%). There were no contractures, non-unions, infections or tendon ruptures. Twenty patients (45%) presented with one or more complications in 23 fractures (41.1%). CONCLUSION These very favourable results suggest that miniature plates and screws are a possible choice in the treatment of these fractures.
Collapse
Affiliation(s)
- Carlo Trevisan
- Clinica Ortopedica Università degli Studi Milano Bicocca, Azienda Ospedale S.Gerardo, Via Donizetti, 106-20052 Monza, Italy.
| | | | | | | |
Collapse
|
14
|
Abstract
Autogenous bone grafting of hand fractures often occurs within the milieu of a complex wound. Risks of infection and/or stiffness increase with injury severity, contamination, and the time interval between injury and successful wound closure or coverage. A clean wound is paramount for successful tissue repair, reconstruction, and closure. Skeletal restoration is an integral component of composite wound management. Fracture stabilization enhances pain control, protects soft tissue repairs and reconstruction, inhibits infection, and facilitates bone graft consolidation and functional recovery. Mini plate fixation provides the sustained stability necessary for hand fractures with bone loss to heal. Bone grafting is an essential element of skeletal restitution for defects due to comminution or actual loss. Cancellous bone grafts heal more rapidly and are more resistant to infection than cortical bone grafts and may be preferable for partial or smaller intercalary defects. Cortical or corticocancellous grafts augment stability and may be especially useful for larger segmental diaphyseal defects and articular bone loss requiring arthrodesis.
Collapse
Affiliation(s)
- Alan E Freeland
- Department of Orthopaedic Surgery and Rehabilitation, University of Mississippi Medical Center, Jackson, MS 39216, USA.
| | | |
Collapse
|
15
|
Abstract
Proximal phalangeal fracture stability is crucial for the initiation of early and effective exercises designed to recover digital and especially proximal interphalangeal joint motion. Active digital flexion and extension exercises are implemented by synergistic wrist motion. Joint blocking exercises and active tendon gliding exercises in protective blocking splints are instrumental elements of early treatment. Dynamic splinting and serial finger casting are used in recalcitrant, severe, and late presenting cases. Surgical release is a last resort in regaining proximal interphalangeal joint motion. This measure is reserved for a failure of treatment when residual proximal interphalangeal joint contracture is persistent and severe enough to cause serious impairment of digital motion and hand function.
Collapse
Affiliation(s)
- Alan E Freeland
- Department of Orthopaedic Surgery and Rehabilitation, University of Mississippi Medical Center, Jackson, Mississippi 39216, USA.
| | | | | |
Collapse
|
16
|
Abstract
Early anatomic (or near anatomic; lingers do not impinge or overlap during flexion or extension) stable fracture fixation provides the foundation for successful wound management and for the repair, reconstruction, and healing of all damaged tissues in a mutilating hand injury. It also plays an instrumental role in pain control and affords an optimal opportunity for timely and favorable rehabilitation of and recovery from mutilating injuries of the hand. Kirschner or other wiring systems or mini external fixators may be used for simple fractures, in children, when rapid fracture fixation is necessary, and for provisional fracture fixation. Mini plates should be considered for fractures with comminution or loss and in instances of multiple fractures. Fingers with segmental injury of three or more tissues should be considered for early amputation to avoid prolonged and impaired recovery of the hand. Every effort should be made to preserve the thumb and its function by repair or reconstruction.
Collapse
Affiliation(s)
- Alan E Freeland
- Department of Orthopaedic Surgery and Rehabilitation, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216, USA.
| | | | | |
Collapse
|
17
|
Abstract
Although the primary objective of replantation is revascularization and ultimately viability of the amputated digit(s), skeletal stabilization is an important cornerstone of the composite repair and reconstructive process. If performed rapidly and securely, anatomic (or near anatomic) fracture reduction and fixation may contribute profoundly to the protection of the revascularization and the repair or reconstruction of nerves, tendons, and integument; reliable fracture healing; functional restoration; and final outcome. Conversely, less than anatomic (or near anatomic) reduction or unreliable and insecure fixation may deter successful early revascularization and, later, good function. This article reviews the various methods of fracture stabilization that may be employed, and their advantages and disadvantages. We believe that anatomic (or near anatomic) fracture reduction, reliable and stable fracture fixation, minimal additional dissection, and early active range-of-motion exercises will have a substantial effect on both viability and functional outcome in digital replantation.
Collapse
Affiliation(s)
- Vipul Sud
- Division of Plastic Surgery, Department of Surgery, University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216, USA.
| | | |
Collapse
|
18
|
Fusetti C, Meyer H, Borisch N, Stern R, Santa DD, Papaloïzos M. Complications of plate fixation in metacarpal fractures. THE JOURNAL OF TRAUMA 2002; 52:535-9. [PMID: 11901331 DOI: 10.1097/00005373-200203000-00019] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
BACKGROUND The objective of this study is to assess the complications after open reduction and plate fixation of extra-articular metacarpal fractures. METHODS We retrospectively reviewed the clinical and radiologic records of 129 consecutive patients with 157 metacarpal fractures treated by open reduction and internal fixation with plates between 1993 and 1999. Intra-articular fractures and fractures of the thumb metacarpal were excluded. Eighty-one patients (64 men and 17 women) with 104 fractures were available for review, at an average follow-up of 13.6 months (range, 6-27 months). RESULTS Twenty-eight patients (35%) and 33 fractures (32%) had one or more complications, including difficulty with fracture healing (12 patients [15%]), stiffness (eight patients [10%]), plate loosening or breakage (seven patients [8%]), complex regional pain syndrome (two patients), and one patient who developed a deep infection. CONCLUSION Despite technical advances in implant material, design, and instrumentation, plate fixation of metacarpal fractures remains fraught with complications and unsatisfactory results.
Collapse
Affiliation(s)
- Cesare Fusetti
- Hand Surgery Unit, Division for Reconstructive Surgery, University Hospital of Geneva, Geneva, Switzerland
| | | | | | | | | | | |
Collapse
|
19
|
Van Oosterom FJ, Brete GJ, Ozdemir C, Hovius SE. Treatment of phalangeal fractures in severely injured hands. JOURNAL OF HAND SURGERY (EDINBURGH, SCOTLAND) 2001; 26:108-11. [PMID: 11281660 DOI: 10.1054/jhsb.2000.0486] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
This retrospective study was performed to assess the incidence of complications of operative treatment of phalangeal fractures. Risk factors for the development of complications were also investigated. Records and radiographs of 350 patients with 666 operatively treated phalangeal fractures were studied. Minimum follow-up was 1 year. A total of 176 fractured fingers were amputated primarily or secondarily, leaving 490 fractures for follow-up. Ninety-three fractures were treated conservatively. Nonunion necessitating reoperation developed in 6% (31/490) of fractures, malunion in 9% (44/490) and infection in 2% (8/490). Infection, segmental bone loss and (neuro)vascular injury predisposed to nonunion and replantation predisposed to malunion. There was a statistical correlation between the use of external fixation and malunion. Nonunion, malunion, and infection rates were similar to other studies.
Collapse
Affiliation(s)
- F J Van Oosterom
- Department of Plastic and Reconstructive Surgery, Academical Hospital Rotterdam, The Netherlands
| | | | | | | |
Collapse
|
20
|
Abstract
Bone is among the most frequently injured of tissues, and bony injuries are among the conditions most commonly treated by hand therapists. An understanding of the biology of bony tissue repair, as well as the techniques available for its promotion, is therefore of the utmost importance to practitioners of hand therapy. This article addresses the biology of bony tissue repair, techniques currently available for the treatment of bony injuries, and management of specific bony injuries of the hand.
Collapse
Affiliation(s)
- J F Slade
- Department of Orthopaedics and Rehabilitation, Yale University School of Medicine, New Haven, CT 06520-8071, USA
| | | |
Collapse
|
21
|
Affiliation(s)
- P J Stern
- Department of Orthopaedic Surgery, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
22
|
Abstract
Diaphyseal fractures of the metacarpals and phalanges are common injuries that can lead to impairment of hand function. The fracture pattern and soft-tissue injury vary with the mechanism of injury. The imbalance of the flexor and extensor forces created by displaced fractures will often produce a secondary angulatory deformity. Nonoperative treatment is indicated for reducible and stable fracture configurations. Irreducible or unstable fracture patterns require open or closed reduction and fixation. Reduction must be assessed in flexion and extension to ensure correct rotatory alignment. Fracture fixation can be achieved with the use of Kirschner wires, interfragmentary screws, or plates. The outcome after surgery is greatly influenced by the condition of the surrounding soft tissues; therefore, surgical trauma should be minimized to optimize the result.
Collapse
Affiliation(s)
- S H Kozin
- Department of Orthopaedic Surgery, Temple University, Philadelphia, PA, USA
| | | | | |
Collapse
|
23
|
O'Sullivan ST, Limantzakis G, Kay SP. The role of low-profile titanium miniplates in emergency and elective hand surgery. JOURNAL OF HAND SURGERY (EDINBURGH, SCOTLAND) 1999; 24:347-9. [PMID: 10433452 DOI: 10.1054/jhsb.1998.0217] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
We report our experience of a low-profile mini-plating system in the treatment of fractures of the hand in 57 consecutive patients (five children and 52 adults). Thirteen procedures were performed electively, and 44 procedures were performed on an emergency basis. Indications for plating included fixation of metacarpal (36) and phalangeal (eight) fractures, bony fixation following rotation osteotomy (six) digital replantation (two) or free toe transfer (two). Seventeen patients had postoperative problems, including restricted range of motion (12), rotation deformity (two), significant cold intolerance (two) or fracture (two). Plate removal was required in seven patients, twice as a result of a second injury, and plate removal was unsuccessfully attempted in one other patient. Two patients required extensor tenolysis. We have found this system to be useful for bony fixation in the hand. However, as with other methods of internal fixation in the hand, there may be complications.
Collapse
Affiliation(s)
- S T O'Sullivan
- Department of Plastic, Reconstructive and Hand Surgery, St James's University Hospital, Leeds, UK
| | | | | |
Collapse
|
24
|
Page SM, Stern PJ. Complications and range of motion following plate fixation of metacarpal and phalangeal fractures. J Hand Surg Am 1998; 23:827-32. [PMID: 9763256 DOI: 10.1016/s0363-5023(98)80157-3] [Citation(s) in RCA: 230] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Eighty-two patients with 105 metacarpal and/or phalangeal fractures stabilized with plates were retrospectively reviewed to assess complications and outcomes. Despite stable fixation and early mobilization, major complications were encountered in 36% of fractures, especially with phalangeal and open fractures. Complications included stiffness, nonunion, plate prominence, infection, and tendon rupture. Forty-eight of 63 (76%) metacarpal fractures and 44 of 66 (67%) closed fractures had a final range of motion greater than 220 degrees; however, only 4 of 37 (11%) phalangeal fractures and 8 of 34 (24%) open fractures achieved this outcome. Despite technical advances in plate design and instrumentation, including lower-profile titanium plates, complications occur commonly with metacarpal and phalangeal fractures, leading to a high incidence of unsatisfactory results. We do not condemn plate fixation, and attribute many of our unsatisfactory results to the frequent use of plates in open and phalangeal fractures.
Collapse
Affiliation(s)
- S M Page
- Department of Orthopedic Surgery, University of Cincinnati College of Medicine and Cincinnati Hand Surgery Specialists, OH 45206, USA
| | | |
Collapse
|